Loading...
HomeMy WebLinkAbout1925 W 8th St - Engineering ~VORT -v..Q ~~ ~'~,t.., ."~~ it .!M L~ ~ ~~ CITY OF PORT ANGELES PUBLIC WORKS - UTILITIES DIVISION 321 EAST 5TH STREET, PORT ANGELES, WA 98362 Appllcatlon Number Appllcatlon pln number Property Address ASSESSOR PARCEL NUMBER: Application type description Subdivislon Name Property Use Property Zoning . . . Application valuation 05-00000557 Date 646892 1925 W 8TH ST 06-30-00-8-5-0215-0000- RES NEW SFR 3/30/06 RS7 RESDNTL SINGLE FAMILY 147714 Owner Contractor COZI HOMES CONSTRUCTION INC. 324 EAST 9TH ST PORT ANGELES WA 98362 (360) 452-9906 Other struct info COZI HOMES CONSTRUCTION 324 E 9TH ST PORT ANGELES (360) 452-9906 TOTAL % LOT COVERAGE NUMBER OF STORIES LOT SIZE TOTAL LOT COVERAGE NUMBER OF UNITS INC WA 98362 29.17 2.00 7000.00 2042.00 1. 00 Permit PUBLIC WORKS RES WATER SERV Additional desc 3/4 " DROP IN WATER METER Permlt pin number 54684 Permit Fee 195.00 Plan Check Fee .00 Issue Date 9/08/05 Valuation 147714 Explratlon Date 8/21/06 BASE FEE Extension 195.00 Qty Unlt Charge Per Permlt . . . . . Additional desc . Permit pin number Permit Fee Issue Date Explratlon Date RIGHT OF WAY 54700 50.00 9/08/05 8/21/06 Plan Check Fee Valuation .00 147714 Qty 1. 00 Unit Charge Per 50.0000 ECH RIGHT OF WAY PERMIT Extension 50.00 Permit . . . . . Additional desc . Permit pin number Permit Fee Issue Date Expiratlon Date SANITARY SEWER HOOK UP 54692 110.00 9/08/05 8/21/06 Plan Check Fee Valuatlon .00 147714 Qty 1. 00 Unlt Charge Per 110.0000 EA SAN SEWER HOOKUP Extension 110.00 Speclal Notes and Comments Buildlng address sign shall not be less than 6" & not more than 12" In helght. Numbers colors must contrast with wall color they are mounted on. (Ord. 14.36.050-E) When roof gutters are lnstalled, dralns wlII located In dry wells or plped to approved storm drain locatlon. No pressurized or pumping to curbs are allowed An lnspectlon Separate Permits are required for electrical work, SEPA, Shoreline, ESA, utilities, private and public Improvements. This permit becomes null and void if work or construction authorized is not commenced Within 180 days, if construction or work is suspended or abandoned for a period of 180 days after the work as commenced, or If required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied With whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. Signature of Owner (if owner IS builder) Date Signature of Contractor or AuthOrized Agent Date T.\PohCles\1102.15R [1105] PERMIT INSPECTION RECORD " CALL 417 -4807 FOR UTILITY INSPECTIONS PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLA WFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT IN A CONSPICUOUS LOCATION. KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE INSPECTION TYPE DATE ACCEPTED COMMENTS YES I NO PW UTILITIES (Engmeenng DIvIsIon) WATERLINE / METER SEWER CONNECTION SANITARY STORM SITE DRAINAGE SITE EROSION CONTROL PARKING SIDEWALK CURB & GUTTER DRIVEWAY APPROACH BACK-FLOW DEVICE FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/uSE RESIDENTIAL DATE YES NO COMMERCIAL DATE ACCEPTED YES NO CONSTRUCTION R W / PW/ CONSTRUCTION - R W. ENGINEERING 417-4807 PW / ENGINEERING FIRE 417-4653 FIRE DEPT. PLANNING DEPT 417-4750 PLANNING DEPT. BUILDING 417-4815 BUILDING T \PohclesII102.15R [1105] CITY OF PORT ANGELES PUBLIC WORKS - UTILITIES DIVISION 321 EAST 5TH STREET, PORT ANGELES, WA 98362 Application Number . . . . . 05-00000557 Application pin number 646892 Page Date 2 3/30/06 Special Notes and Comments by Building Department is required prior to backfill. 07/12/2005 04:48 PM SROBERDS -- The proposal will result In a s.f. res In the RS-7 for total lot coverage of 29%. Improvement to fronting street is required. No land use issues are noted. Electrlcal load calculatlons and elctrlcal permits are requlred Electrical connection fee of $410.00 required. 07/06/2005 03:37 PM GMCLAIN ---------------------------- Sanitary sewer connection inspection is required by Publlc Works prlor to back flll of ditch. Other Fees SEWER SYSTEM DELV CHARGE STATE SURCHARGE PW WATER SYSTEM USE FEE 745.00 4.50 1025.00 Fee summary Charged Paid Credlted Due Permit Fee Total Plan Check Total Other Fee Total Grand Total 355.00 .00 1774.50 2129.50 355.00 .00 1774.50 2129.50 .00 .00 .00 .00 .00 .00 .00 .00 Separate Permits are required for electrical work, SEPA, Shoreline, ESA, utilities, private and public Improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned for a period of 180 days after the work as commenced, or if required inspections have not been requested within 180 days from the last inspection I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. Signature of Owner (if owner is bUilder) Date Signature of Contractor or Authorized Agent Date T.\Pohcles\1102 15R [1/05] PERMIT INSPECTION RECORD " CALL 417-4807 FOR UTILITY INSPECTIONS PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLA WFUL TO COVER, , INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT IN A CONSPICUOUS LOCATION. KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE INSPECTION TYPE DATE ACCEPTED COMMENTS I YES NO PW UTILITIES (Engmeenng DIvIsIOn) WATERLINE / METER I SEWER CONNECTION SANITARY STORM SITE DRAINAGE SITE EROSION CONTROL PARKING SIDEWALK CURB & GUTTER DRIVEWAY APPROACH BACK-FLOW DEVICE I FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE RESIDENTIAL DATE YES NO COMMERCIAL DATE ACCEPTED YES NO CONSTRUCTION R W / PW/ CONSTRUCTION - R.W. ENGINEERING 417-4807 PW / ENGINEERING FIRE 417-4653 FIRE DEPT. PLANNING DEPT 417-4750 PLANNING DEPT. BUILDING 417-4815 BUILDING T \Pohcles\1I02 15R [1/05] . , f?ORTA..o; "...O~1 <; r'&fiij~ ~ -- "iC;:,;;P CITY OF PORT ANGELES PUBLIC WORKS - UTILITIES DIVISION 321 EAST 5TH STREET, PORT ANGELES, WA 98362 O~-667 CQZI HOMES CONSTRUCTION 324 E 9TH ST PORT ANGELES (360) 452-9906 TOTAL % LOT COVERAGE NUMBER OF STORIES LOT SIZE TOTAL LOT COVERAGE NUMBER OF UNITS Qty Unit Charge Per ~. BASE FEE 195.00 ~--------------------------------------------------------------- Permi t RIGHT OF WAY Additional desc . Permit pin number Permit Fee Issue Date Expiration Date Qty Unit Charge Per ~. 1.00 50.0000 ECH RIGHT OF WAY PERMIT 50.,00 ----------------------------------------------------------------- ------- Permit . . . .. SANITARY SEWER HOOK UP Additional desc . Permit pin number Permit Fee Issue Date Expiration Date Application Number Application pin number Property Address ASSESSOR PARCEL NUMBER: Application type description Subdivision Name Property Use Property Zoning Application valuation Owner C02I HOMES CONSTRUCTION INC. 324 EAST 9TH ST PORT ANGELES WA 98362 (360) 452-9906 Other struct info Permit Additional desc . Permit pin number Permit Fee Issue Date Expiration Date PUBLIC WORKS 3/4" DROP IN 54684 195.00 9/08/05 8/21/06 54700 50.00 9/08/05 8/21/06 54692 110.00 9/08/05 8/21/06 3/30/06 /1ZS-JV8 ib 05-00000557 Date 646892 1925 W 8TH ST 06-30-00-8-5-0215-0000- RES NEW SFR RS7 RESDNTL SINGLE FAMILY 147714 C:;tJ.::a ~~ Contractor INC WA 98362 29.17 2.00 7000.00 2042.00 1. 00 RES WATER SERV WATER METER Plan Check Fee Valuation .00 147714 plan Check Fee Valuation .00 147714 1/ Plan Check Fee. Valuation' .00 147714 ________=~~~___~~:~l~h~~~~_E~e:__:~_:~~~~_~~~~uP______________~~ special Notes and Comments Building address sign shall not be less than 6" & not more than 12" in height. Numbers colors must contrast with wall color they are mounted on. (Ord. 14.36.050-El When roof gutters are installed, drains will located in dry wells or piped to approved storm drain location. No pressurized or pumping to curbs are allowed. An inspection Separate Permits are required for electrical work, SEPA, Shoreline, ESA, utilities, private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days, if construction orwork is suspended or abandoned for a period of 180 days aflerthe work as commenced, or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whelher specified herein or not. The granting of a permit does not presume to give aulhority to violate or cancel Ihe provisions of any slate or local law regulating construcllon or the performance of construction. Signalure of Contractor or Aulhorized Agenl Dale Signature of Owner (If owner is builder) Date T:\Policies\1 102.15R [1/05] , cfrvORT-v. /~%-~ ,.~ ~~ ~ ""<~ CITY OF PORT ANGELES PUBLIC WORKS - UTILITIES DIVISION 321 EAST 5TH STREET, PORT ANGELES, W A 98362 Application Number Application pin number 05-00000557 646892 Page Date 2 3/30/06 Special Notes and Comments by Building Department is required prior to backfill. 07/12/2005 04:48 PM SROBERDS -- The proposal will result in a s.f. res in the RS-7 for total lot coverage of 29%. Improvement to fronting street is required. No land use issues are noted. Electrical load calculations and elctrical permits are required. Electrical connection fee of $410.00 required. 07/06/2005 03;37 PM GMCLAIN ---------------------------- Sanitary sewer connection inspection is required by Public Works prior to back fill of ditch. -----~~~~~-;~~~--~-~-~-~-~-~-~-~-~--~~~~~-~~~;~~-~~~;-;~~~--~;~~~;~- STATE SURCHARGE ~ ~~ _________________________________~__~~_~~=~~_:=:=~~_~:~_~~~_~ ~25.00 ~_ Fee summary Charged Paid Credited Due Permit Fee Total plan Check Total Other Fee Total Grand Total 355.00 .00 1774.50 2129.50 355.00 .00 1774.50 2129.50 .00 .00 .00 .00 .00 .00 .00 .00 Separate Permits are required for electrical work, SEPA, Shoreline, ESA, utilities, private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned for a period of 180 days after the work as commenced, or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true' and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. Signature of Contractor or Authorized Agent Date Signature of Owner (if owner is builder) Date T;\Policies\1 l02.15R (1/05] /~1 b~ rJ" I i~"X,.S. ,.J APPLICATION FOR WATER City Water Division Port Angeles. Washington q-Df> ~S . 20_ I hereby apply for water to be furnished in accordance with rates and rules of the City for the following premises: 3:P<t e. 9f~ 4'5'2 -99Db Lk~~ 2. fOI.c,L.EI<) Lot Add !=VAI1S 51..113 Meter Number ()S'6-;(O 7'7/5 Service Left Off V Signed ~., ~ ;/1~ Name of Applicant: ~ 02.6: He WI r;:S Address: 19~5 W. B-Ks~. Renewal 0 New Service DBlk. Size of Service h 3/4 D Ro P -"1:.1'1 Service Left On 0 Installed by Remarks: Pl;em1:Tt!o0<5 ~ jJ 195.C!:. .j-ID;).S. ~ J3?1 PAI2.c.C;I.-"tJ.. O"'3oo0~5 O~150000 (FreE SPRJ::I\II:.LI;) w 5~/vc..- 'ETI... N II .... $ ~ ~~ s 4J '. r: I~/' -4f E s CITY OF PORT ANGELES DEPARTMENT OF PUBLIC WORKS . . . . . . . . . . . INSPECTION REPORT. . . . . . . . . . . REQUEST: Date 4 - 5 - Clb Time Received by (phone, person) Location of Work to be inspected Name of person requesting inspection (Y\: I:::. eo Address of person requesting inspection Type of Inspection (circle appropriate one): ~oundation Framing Chimney Plumbing 1'1;('1 uJ. B~-~+. ~...i~e.O - c.. 02I 1-10111$ S Phone No.4"O - &,6 t ( Permit No. 05" - S'S' 7 Final Sewer Excav. Other INSPECTION NOTES: Inspected: Date Lj - I D - 0 c.:. Time -:.:?: ~ P'" By . ~ '(VI. :J.-.;- Remarks: Lo \-c. d ~Cl--.) Co. U,) e c..~ 11./0' E 0 1'11-1. ~ i::. ~>'I So .{.. Cc.-.J.L ' dee p :r::""'So-\'A[l-('. lPttPVC-p"r'l!'".\-e, pl"Or~J..1' \2E.due~-k> '-III PII(:..-t-o c..O. loc.A.'\..c-J c..*- h..o~~ -e. RESTORATION REQUIRED.,.,.. YES NO )( d,,,c,u...l A-tl"(' 'is '. iD" fvt:.. -" l~ - '",/0' e- f:L.GI"", 3 '-I." pvc- A-Il~ 4 to'- /fl' Pllt.. (."1'#" .2.. ec!',:< e."'''''' a.. PIt.... ~ '-I~-r.."":"_fl"PVc.. [Xf"Co18-e",c!', f~ ii VI ~ 'It ~ ill --.. ;,/'''- ..--c.o. ...., ::::::..-- I ' Iq~1f> SURFACE RESTORATION: SURFACE TYPE: 0 Unimproved OGravel o Asphalt OPCC o Other o Repaired by City o Repaired by Permittee o No Damage Found Work Order # o COMPLETE o INCOMPLETE (/'1