Loading...
HomeMy WebLinkAbout1831 W 13th St - Building . CITY OF PORT ANGELES LIGHT DEPARTMENT 321 E. Fifth Street Port Angeles, WA 98362 (206) 457-0411 ELECTRICAL PERMIT PERMIT NO. 9'.3 J> P ////t./f:>J , r DATE Site Address: o READY FOR INSPECTION License Number: o WILL CALL FOR INSPECTION Phone: Installed By: Owner/Business: Phone: Owner/Business Address: Sq. Ft. t'JK'RESIDENTIAL o COMMERCIAL . f ~ BASEBOARD KW ~ o FURNACE KW _ o FAN/WALL KW _ o HEAT PUMP KW_ o SIGN o TEMPORARY SERVICE \l!Q' PERMANENT SERVICE ')ZJ NEW CONSTRUCTION '[] REMODEL o ADD/ALTER CIRCUITS o SERVICE UPGRADE/REPAIR o SPECIAL EQUIPMENT (LIST BELOW) o OVERHEAD SERVICE ;g- UNDER~U~~RVICE VOLTAGE: ") 0 RI SINGLE PHASE . b THREE PHASE SERVICE SIZE c;l>f) AMPS DetailslDescription: Altu) ~~ . . W.S. No. SERVICE SIZE CAPACITY: o O.K. NOT O.K. ACTION REQUIRED: 0 CHANGE TRANSFORMER o INSTALL SERVICE POLE DATE ENGR. o CHANGE SERVICE WIRE D OTHER o Ditch Inspection O.K. 1tiV'.'Efl. Rough-in/cover O.K. Ff1 O.K. to connect service Ap-4J Final O.K. If/ r '--1 Site Address: Installer: permit13Sg New Meters I . Notify Port Angeles City Light by Street Address and Permit Number when ready for inspection. Work must not be covered before inspection and O.K. for covering has been given by the electrical inspector in writing on either the Wiring Report or on the Building Permit. PHONE 457-0411, EXT. 224. NO OCCUPANCY OR USE ESTABLISHED UNDER THIS PERMIT $ (Xl $[)- Elec1ricallnspector Permit Fee WHITE - File by address YELLOW - file by number PINK - Top: Eng, Bottom, Customer GREEN - Top: Meter Dept., Bottom: City Half OLYMPIC PRINTERS INC. Application Number . . . . . 23-00001273 Date 12/07/23 Application pin number . . . 786169 Property Address . . . . . . 1831 W 13TH ST ASSESSOR PARCEL NUMBER: 06-30-00-0-3-6260-0000- Application type description ELECTRICAL ONLY Subdivision Name . . . . . . Property Use . . . . . . . . Property Zoning . . . . . . . PUBLIC BUILDINGS & PARKS Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc PV system ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ WILLIAM CORTANI III SOLGEN POWER LLC 1831 W 13TH ST 5715 BEDFORD STREET PORT ANGELES WA 98363 PASCO WA 99301 (360) 640-3294 (509) 931-1663 ---------------------------------------------------------------------------- Permit . . . . . . ELECTRICAL ALTER RESIDENTIAL Additional desc . . Permit Fee . . . . 102.00 Plan Check Fee . . .00 Issue Date . . . . 12/07/23 Valuation . . . . 0 Expiration Date . . 6/04/24 Qty Unit Charge Per Extension 1.00 102.0000 ECH EL-RENEWABLE 5-KVA OR LESS 102.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 102.00 102.00 .00 .00 Plan Check Total .00 .00 .00 .00 Grand Total 102.00 102.00 .00 .00 Public Works and Utilities Department 321 E. 5th Street, Port Angeles, WA 98362 360.417.4735 | www.cityofpa.us | electricalpermits@cityofpa.us EL1-2 SF 1 - 2 SINGLE-FAMILY ELECTRICAL PERMIT APPLICATION Project Address: Project Description: □ Single-Family Residential □ Duplex / ARU Building Square footage: OWNER INFORMATION Name: Email: Mailing Address: Phone: ELECTRICAL CONTRACTOR INFORMATION Name: License: Mailing Address: Expiration Date: Email: Phone: PROJECT DETAILS Item Unit Charge Quantity Total (Quantity x Unit Charge) Service/Feeder 200 Amp.$120.00 $ Service/Feeder 201-400 Amp.$146.00 $ Service/Feeder 401-600 Amp.$205.00 $ Service/Feeder 601-1000 Amp.$262.00 $ Service/Feeder over 1000 Amp.$373.00 $ Branch Circuit W/ Service Feeder $5.00 $ Branch Circuit W/O Service Feeder $63.00 $ Each Additional Branch Circuit $5.00 $ Branch Circuits 1-4 $75.00 $ Temp. Service/Feeder 200 Amp.$93.00 $ Temp. Service/Feeder 201-400 Amp.$110.00 $ Temp. Service/Feeder 401-600 Amp.$149.00 $ Temp. Service/Feeder 601-1000 Amp.$168.00 $ Portal to Portal Hourly $96.00 $ Signal Circuit/Limited Energy - 1&2 DU.$64.00 $ Manufactured Home Connection $120.00 $ Renewable Elec. Energy: 5KVA System or less $102.00 $ Thermostat (Note: $5 for each additional)$56.00 $ First 1300 Square Feet $120.00 $ Each Additional 500 square feet``$40.00 $ Each Outbuilding / Detached Garage $74.00 $ Each Swimming Pool / Hot Tub $110.00 $ TOTAL $ Owner as defined by RCW.19.28.261: (1) Owner will occupy the structure for two years after this electrical permit is finalized. (2) Owner is required to hire an electrical contractor if above said property is for sale, rent or lease. Permit expires after six months of last inspection. After reading the above statement, I hereby certify that I am the owner of the above named property or a licensed electrical contractor. I am making the electrical installation or alteration in compliance with the electrical laws, N.E.C., RCW. Chapter 19.28, WAC. Chapter 296- 46B, The City of Port Angeles Municipal Code, and Utility Specifications and PAMC 14.05.050 regarding Electrical Permit Applications. Date Print Name Signature (□ Owner □ Electrical Contractor / Administrator)Permit #: New Construction Only [Electrical Permit Applications may be submitted to City Hall or electricalpermits@cityofpa.us or faxed to 360.417.4711] PREPARED 11/30/23,10:20:57 PAYMENT DUE CITY OF PORT ANGELES PROGRAM BP820L --------------------------------------------------------------------------- APPLICATION NUMBER:23-00001273 1831 W 13TH ST FEE DESCRIPTION AMOUNT DUE --------------------------------------------------------------------------- ELECTRICAL ALTER RESIDENTIAL 102.00 TOTAL DUE 102.00 Please present reciept to the cashier with full payment William Cortani III1831 W 13th St, Port Angeles, WA 98363DRAWN BY:DATE:11/08/2023MGDESIGNSOLGEN POWER5715 BEDFORD ST,PASCO, WA 99301P: 509-931-16631PAGE #PV 1ABCDEFGH12345 54321GENERAL NOTES1. PRIOR TO THE COMMENCEMENT OF ANYWORK, THE CONTRACTOR SHALL NOTIFYTHE DESIGNER OF ANY DISCREPANCIESWITH THE DESIGN IN ANY CAPACITY.ESPECIALLY RECOMMENDATIONS, CODES,OR REGULATIONS & RULES OF THEAUTHORITY HAVING JURISDICTION, WHICHSUPERSEDED THE NEC.2. ALL DIMENSIONS TO BE VERIFIED BYCONTRACTOR PRIOR TO COMMENCEMENTOF WORK.3. CONTRACTOR IS RESPONSIBLE FOR ALLSAFETY PRECAUTIONS, OSHAREQUIREMENTS ETC. FOR THE SITE,INCLUDING EXISTING SITE HAZARDS.4. SYSTEM IS GRID INTERACTIVE/INTERTIEDVIA A UL LISTED POWER-CONDITIONINGINVERTER.5. SYSTEM HAS NO ENERGY STORAGE OFANY KIND, OR UPS.6. ALL SOLAR MOUNTING FRAMEWORK TOBE GROUNDED.7. FOLLOW MANUFACTURERS SUGGESTEDINSTALLATION PRACTICES AND WIRINGSPECIFICATIONS.8. ALL WORK TO BE IN COMPLIANCE WITHTHE INTERNATIONAL BUILDING CODES.(IBC)9. ALL ELECTRICAL WORK TO BE INCOMPLIANCE WITH THE NATIONALELECTRIC CODE (NEC).ELECTRICAL NOTES1. WHERE ALL TERMINALS OF THEDISCONNECTING MEANS MAY BEENERGIZED IN THE OPEN POSITION, ASIGN WILL BE PROVIDED WARNING OFTHE HAZARDS. (PER ART. 690.17)2. EACH UNGROUNDED CONDUCTOR OFTHE MULTIWIRE BRANCH CIRCUIT WILLBE IDENTIFIED BY PHASE AND SYSTEM.(PER ART. 210.5)3. A NATIONALLY RECOGNIZED TESTINGLABORATORY SHALL LIST ALLEQUIPMENT IN COMPLIANCE WITHARTICLE 110.3.4. ALL WIRES SHALL BE PROVIDED WITHSTRAIN RELIEF AT ALL ENTRY POINTSINTO BOXES AS REQUIRED BY UL LISTING5. MODULE FRAMES SHALL BE GROUNDEDAT THE UL-LISTED LOCATION PROVIDEDBY THE MANUFACTURER USINGUL-LISTED GROUNDING HARDWARE.6. MODULE FRAMES, RAIL, AND POSTSSHALL BE BONDED WITH EQUIPMENTGROUND CONDUCTORS AND GROUNDEDAT THE MAIN ELECTRICAL PANEL.7. THE DC GROUNDING ELECTRODECONDUCTOR SHALL BE SIZEDACCORDING TO ARTICLE 250.166B &690.47.AERIAL VIEWRESIDENCE PHOTOSHEET INDEXPV 1 COVER PAGEPV 2 SITE PLANPV 3 ELECTRICAL DIAGRAMPV 6 PLACARDCONFIDENTIAL - THE INFORMATION CONTAINEDIN THIS PACKET AND SUBSEQUENT CUTSHEETSSHALL NOT BE USED FOR THE BENEFIT OFANYONE OUTSIDE SOLGEN POWER. NEITHERSHALL IT BE DISCLOSED TO OTHERS OUTSIDETHE RECIPIENT'S ORGANIZATION, EXCEPT INCONNECTION WITH THE SALE AND USE OF THERESPECTIVE EQUIPMENT, WITHOUT WRITTENCONSENT FROM SOLGEN POWER.CUT SHEETS ATTACHEDPV 4 CHIKO MOUNTINGPV 5 MOUNTING DIAGRAMSTRUCTURAL ONLY08/11/2023CONFIGURE FOR IEEE 1547 ANTI-ISLANDING GRID NEWSINDEX:NUMBER OF MODULES:14MODULE TYPE:INVERTER:MODULESMAIN SERVICEZNSHINEZXM6-NH120-360MHoymiles Series3COMBINER BOX4124" O.C.2" x 4"TRUSS SPACING:TRUSS SIZE:SYSTEM SIZE DC:SYSTEM SIZE AC:SYSTEM SIZE DC:5.040kWSYSTEM SIZE AC:4.200kWSYSTEM SIZE DC:SYSTEM SIZE AC:AC DISCONNECT5UTILITY METER21'-6"1'-6"1'-6"1'-6"William Cortani III1831 W 13th St, Port Angeles, WA 98363DRAWN BY:DATE:11/08/2023MGABCDEFGH12345 54321DESIGN1PAGE #PV 21/8" = 1'-0"DRAWING SCALE:SOLGEN POWER5715 BEDFORD ST,PASCO, WA 99301P: 509-931-1663CONFIDENTIAL - THE INFORMATION CONTAINEDIN THIS PACKET AND SUBSEQUENT CUTSHEETSSHALL NOT BE USED FOR THE BENEFIT OFANYONE OUTSIDE SOLGEN POWER. NEITHERSHALL IT BE DISCLOSED TO OTHERS OUTSIDETHE RECIPIENT'S ORGANIZATION, EXCEPT INCONNECTION WITH THE SALE AND USE OF THERESPECTIVE EQUIPMENT, WITHOUT WRITTENCONSENT FROM SOLGEN POWER.ROOF AREA: 1860Ft2PV AREA: 274.76Ft2ROOF %: 14.77%CIRCUIT 1CIRCUIT 2SOLAR OFFSET1COMP. SHINGLEWAC 51-54A-1204.2.1IFC 2018EXCEPTION 53425STRUCTURAL ONLY08/11/2023 (N) UTILITYAC DISCONNECT240V/30A NEMA 3RNON-FUSIBLE,VISIBLE-LOCKABLELABELED(N) PV OCPD2P - 30A(E) LOADS200AMAINDISCONNECTUTILITYSERVICE120/240VSINGLE PHASE200A RATEDMAIN SERVICEPANELL1GN-G30A LOAD-SIDESOLAR OCPD(Opposite end of the main disconnecton the busbar - NEC 705.12(B)(3)FACILITY GROUNDGROUND RODNEMA3R RATEDJUNCTION BOX: SHALLCOMPLY W/ NEC 110.3& 314.6(N) 240V/60A PV125A LOAD CENTER, NEMA 3R RATED348128 ZNSHINE ZXM6-NH120-360M MODULESWITH HOYMILES HM-1200 MICRO INVERTERS3412124 ZNSHINE ZXM6-NH120-360M MODULESWITH HOYMILES HM-1200 MICRO INVERTERS2 ZNSHINE ZXM6-NH120-360M MODULESWITH HOYMILES HM-600 MICRO INVERTERS20A20AWilliam Cortani III1831 W 13th St, Port Angeles, WA 98363DRAWN BY:DATE:11/08/2023MGABCDEFGH12345 54321DESIGN1PAGE #PV 3NOT TO SCALEDRAWING SCALE:SOLGEN POWER5715 BEDFORD ST,PASCO, WA 99301P: 509-931-1663CONFIDENTIAL - THE INFORMATION CONTAINEDIN THIS PACKET AND SUBSEQUENT CUTSHEETSSHALL NOT BE USED FOR THE BENEFIT OFANYONE OUTSIDE SOLGEN POWER. NEITHERSHALL IT BE DISCLOSED TO OTHERS OUTSIDETHE RECIPIENT'S ORGANIZATION, EXCEPT INCONNECTION WITH THE SALE AND USE OF THERESPECTIVE EQUIPMENT, WITHOUT WRITTENCONSENT FROM SOLGEN POWER.LOAD CALCS - TOTAL AMPS AVAILABLEBUS RATING 120%TOTALMAIN BREAKERX=-=MAX BREAKER SIZE200A1.2240200A40ABREAKER SIZE CALCSMAX AC OPERATING CURRENT125%TOTAL BREAKER SIZE17.46Ax1.25x21.83A=30ACOMBINER BOX PANEL SIZE CALCSNUMBER OFMODULESNOMINAL OUTPUTCURRENTTOTAL 125%CIRCUIT #BREAKER SIZETOTALNUMBER OFMICROINVERTERSCOMBINEDTOTAL123C3#8 AWGTHWN-2, CU#8 AWGTHWN-2, CUD**4#8 AWGTHWN-2, CU#8 AWGTHWN-2, CU* TAG A CABLE WILL BE RUN THROUGH ATTIC WHERE POSSIBLE ** TAG D ONLY IF APPLICABLE *CONDUCTOR SCHEDULECONDUCTORSGROUNDTAG IDWIRES INCONDUITMINIMUMWIRE SIZETYPE, MATERIALMINIMUMWIRE SIZETYPE, MATERIALA*6#12 AWGPV CABLE, CU#6 AWGBARE, CUB5#12 AWGTHWN-2, CU#8 AWGTHWN-2, CUMAX AC OPERATINGCURRENT FOR HM-1200, 600, 300INVERTERTYPENUMBERR OFINVERTERSNOMINAL OUTPUTCURRENTTOTALCOMBINEDTOTALHM-12003X 5.0A = 15.00A=17.46AHM-6001X 2.46A = 2.46AHM-3000X1.23A=0.00A4NOTES:1. 200A UTILITY METER GLOBE ONLY. (EXISTING)2. 200A LOAD CENTER. (EXISTING)3. 30A RATED NON-FUSED LOCKABLE AC DISCONNECT. (NEW)4. 125A RATED COMBINER PANEL. (NEW)ALL CONDUIT SIZES ARE MINIMUM SIZESALL WIRE SIZES ARE FOR COPPER WIREX=8CIRCUIT 125.0A=x1.25==N/A10.00A12.50A20AX=2CIRCUIT 2 (1 of 2)1CIRCUIT 2 (2 of 2)X==412.46A5.0A=x1.25=3.08A=9.33Ax1.25=20A2.46A5.00A6.25ACONFIGURE FOR IEEE 1547 ANTI-ISLANDING GRID William Cortani III1831 W 13th St, Port Angeles, WA 98363DRAWN BY:DATE:11/08/2023MGDESIGN1PAGE #PV 4ABCDEFGH12345 54321STRUCTURAL NOTES:1.TOTAL WEIGHT (MODULE & RAIL): 690 LBS2.RAIL WEIGHT: 57 LBS3.MODULE WEIGHT: 633 LBS4.DISTRIBUTED WEIGHT: 2.58 PSFSOLGEN POWER5715 BEDFORD ST,PASCO, WA 99301P: 509-931-1663CONFIDENTIAL - THE INFORMATION CONTAINEDIN THIS PACKET AND SUBSEQUENT CUTSHEETSSHALL NOT BE USED FOR THE BENEFIT OFANYONE OUTSIDE SOLGEN POWER. NEITHERSHALL IT BE DISCLOSED TO OTHERS OUTSIDETHE RECIPIENT'S ORGANIZATION, EXCEPT INCONNECTION WITH THE SALE AND USE OF THERESPECTIVE EQUIPMENT, WITHOUT WRITTENCONSENT FROM SOLGEN POWER.5'9"3'5"5'9"0.67"13.8'D4'Mid ClampEnd Clamp4'4'14.24'Grounding Lug6"1.4"ROOFINGSOLAR PANELCHIKO#7 RAILROOF TECHMINI IIL FOOTABINSTALL A OR BDECK MOUNTINGRAFTER/PURLIN/TRUSSROOF TECHMINI IIDOWN SLOPEDOWN SLOPE Minimumembedment 1.5 In.#10 x 2-1/2" HI-HWH StrongShield Pole Gripper ScrewsMinimum Embedment: Thickness of SheathingSTRUCTURAL ONLY08/11/2023 22'51'-8"William Cortani III1831 W 13th St, Port Angeles, WA 98363DRAWN BY:DATE:11/08/2023MGABCDEFGH12345 54321DESIGN1PAGE #PV 53/16" = 1'-0"DRAWING SCALE:STRUCTURAL NOTES:1. 48" MAX SPAN OF RAIL TO DISTRIBUTE WEIGHTOVER SUPPORT OF TRUSSES2. MOUNTING FEET ARE IN APPROXIMATE LOCATION.3. MOUNTING FEET SHOULD BE STAGGERED ASSHOWN IN DIAGRAM2MOUNTING DIAGRAM1MOUNTING DIAGRAMSCALE: NOT TO SCALEROOF 1TILT:22°AZIMUTH:121°SOLGEN POWER5715 BEDFORD ST,PASCO, WA 99301P: 509-931-1663CONFIDENTIAL - THE INFORMATION CONTAINEDIN THIS PACKET AND SUBSEQUENT CUTSHEETSSHALL NOT BE USED FOR THE BENEFIT OFANYONE OUTSIDE SOLGEN POWER. NEITHERSHALL IT BE DISCLOSED TO OTHERS OUTSIDETHE RECIPIENT'S ORGANIZATION, EXCEPT INCONNECTION WITH THE SALE AND USE OF THERESPECTIVE EQUIPMENT, WITHOUT WRITTENCONSENT FROM SOLGEN POWER.MOUNTING FEETPV MODULECHIKO #7 RAIL48"STRUCTURAL ONLY08/11/2023 William Cortani III1831 W 13th St, Port Angeles, WA 98363DRAWN BY:DATE:11/08/2023MGDESIGN1PAGE #PV 6ABCDEFGH12345 54321SOLGEN POWER5715 BEDFORD ST,PASCO, WA 99301P: 509-931-1663CONFIDENTIAL - THE INFORMATION CONTAINEDIN THIS PACKET AND SUBSEQUENT CUTSHEETSSHALL NOT BE USED FOR THE BENEFIT OFANYONE OUTSIDE SOLGEN POWER. NEITHERSHALL IT BE DISCLOSED TO OTHERS OUTSIDETHE RECIPIENT'S ORGANIZATION, EXCEPT INCONNECTION WITH THE SALE AND USE OF THERESPECTIVE EQUIPMENT, WITHOUT WRITTENCONSENT FROM SOLGEN POWER.CAUTIONPOWER TO THIS BUILDING IS SUPPLIED FROM THEFOLLOWING SOURCES WITH DISCONNECTSLOCATED AS SHOWN:6"x6"1831 W 13th St, Port Angeles, WA 98363NEWSSOLAR PV ARRAY WITHMICROINVERTERSROOF MOUNTEDUTILITY METERMAIN SERVICE PANELAC DISCONNECT ZXM6-NH120 Series Znshinesolar 9BB HALF-CELL Black Monocrystalline PERC PV Module Improved Aesthetics 355W丨360W丨365W丨370W丨375W 9BB www.znshinesolar.com Founded in 1988, ZNShine solar is a world’s leading high-tech PV module manufacturer.With the state-of-the-art production lines, the company boasts module capacity of 6GW. Bloomberg has listed ZNShine as a global Tier 1 PV module maker. Today Znshine has distributed its sales to more than 60 countries around the globe. IEC61215/IEC61730/IEC61701/IEC62716/UL61730 ISO 9001: Quality Management System ISO45001: Occupational Health and Safety Management System ISO 14001: Environmental Management System E-mail:info@znshinesolar.comTel:+86 519 6822 0233 Add : 1#, Zhixi Industrial Zone,JintanJiangsu 213251,P.R. China / PACKAGING CONFIGURATION Piece/Box Piece/Container(40’HQ) Piece/Container(with additional small package) Note: please read safety and installation instructions before using this product丨Subject to change without prior notice © ZNSHINE SOLAR 2021丨Version: ZXM6-NH120 2109.E MECHANICAL DATA Solar cells Cells orientation Module dimension Weight Glass Junction box Cables Connectors *STC (Standard Test Condition): Irradiance 1000W/m², Module Temperature 25℃, AM 1.5 *Measuring tolerance: ±3% ELECTRICAL CHARACTERISTICS 丨 STC* Nominal Power Watt Pmax(W)* Power Output Tolerance Pmax(%) Maximum Power Voltage Vmp(V) Maximum Power Current Imp(A) Open Circuit Voltage Voc(V) Short Circuit Current Isc(A) Module Efficiency (%) Maximum Power Pmax(Wp) Maximum Power Voltage Vmpp(V) Maximum Power Current Impp(A) Open Circuit Voltage Voc(V) Short Circuit Current Isc(A) *NMOT(Nominal module operating temperature):Irradiance 800W/m²,Ambient Temperature 20℃,AM 1.5,Wind Speed 1m/s ELECTRICAL CHARACTERISTICS 丨 NMOT* 44℃ ±2℃ -0.36%/℃ -0.29%/℃ 0.05%/℃ 1500 V DC -40℃~+85℃ 20 A 5400 Pa / 2400 Pa TEMPERATURE RATINGS NMOT Temperature coefficient of Pmax Temperature coefficient of Voc Temperature coefficient of Isc WORKING CONDITIONS Maximum system voltage Operating temperature Maximum series fuse Maximum load(snow/wind) *Do not connect Fuse in Combiner Box with two or more strings in parallel connection *Remark:Electrical data in this catalog do not refer to a single module and they are not part of the offer.They only serve for comparison among different module types. I-V CURVES OF PV MODULE(365W) P-V CURVES OF PV MODULE(365W) Voltage [V]Current [A]Voltage [V]Power [W]DIMENSIONS(MM) Front View Back View ZXM6-NH120 Series Znshinesolar 9BB HALF-CELL Black Monocrystalline PERC PV Module Mono PERC 120(6×20) 1755×1038×35 mm(With Frame) 20.5 kg 3.2mm, High Transmission, AR Coated Tempered Glass IP 68,3 diodes 4 mm² ,350 mm MC4-compatible 31 806 0 10 20 30 40 500 2 4 6 8 10 12 14 Incident Irrad. = 1000 W/m² Cells temp. = 25 °C Incident Irrad. = 800 W/m² Incident Irrad. = 600 W/m² Incident Irrad. = 400 W/m² Incident Irrad. = 200 W/m² 0 10 20 30 40 500 50 100 150 200 250 300 350 400 Cells temp. = 25 °C Incident Irrad. = 1000 W/m² Incident Irrad. = 800 W/m² Incident Irrad. = 600 W/m² Incident Irrad. = 400 W/m² Incident Irrad. = 200 W/m² Barcode 2 Mounting holes Label Drainage holes Grounding holes Grounding identification 996±2 Barcode 1 Junction box 375 0~+3 34.40 10.91 41.20 11.51 20.59 365 0~+3 34.00 10.74 40.80 11.33 20.04 360 0~+3 33.80 10.66 40.60 11.24 19.76 370 0~+3 34.20 10.82 41.00 11.42 20.31 279.80 31.90 8.76 38.40 9.29 268.50 31.40 8.55 37.90 9.08 355 0~+3 33.60 10.57 40.40 11.14 19.49 264.70 31.20 8.47 37.70 9.00 272.10 31.60 8.62 38.00 9.15 275.80 31.70 8.69 38.20 9.22 FF0002 DQD 507 Rev. 2019-04-30 © 2018 CSA Group. All rights reserved. Page 1 Certificate of Compliance Certificate: 80049804 Master Contract: 262247 Project: 80049804 Date Issued: 2020-07-21 Issued to: ZNSHINE PV-TECH Co.,Ltd. #1 Zhixi Industry Zone, Jintan, Jiangsu, 213251 China Attention: Xingjuan Rui The products listed below are eligible to bear the CSA Mark shown with adjacent indicators 'C' and 'US' for Canada and US or with adjacent indicator 'US' for US only or without either indicator for Canada only Issued by: Tom Yang Tom Yang PRODUCTS CLASS - C531110 - POWER SUPPLIES-Photovoltaic Modules and Panels CLASS - C531190 - POWER SUPPLIES-Photovoltaic Modules and Panels - Certified to US Standards Mono Crystalline-Si photovoltaic modules with maximum system voltage of 1500 V dc, Safety Class II PV modules. Models with 166 mm Cells ZXM6-NH156-xxx/M, xxx=455 to 485, in step of 5 W ZXM6-NH144-xxx/M, xxx=420 to 450, in step of 5 W ZXM6-NH132-xxx/M, xxx=385 to 410, in step of 5 W ZXM6-NH120-xxx/M, xxx=350 to 375, in step of 5 W ZXM6-NP156-xxx/M, xxx=455 to 485, in step of 5 W ZXM6-NP144-xxx/M, xxx=420 to 450, in step of 5 W ZXM6-NP132-xxx/M, xxx=385 to 410, in step of 5 W ZXM6-NP120-xxx/M, xxx=350 to 375, in step of 5 W ZXM6-NO156-xxx/M, xxx=455 to 485, in step of 5 W ZXM6-NO144-xxx/M, xxx=420 to 450, in step of 5 W Certificate: 80049804 Project: 80049804 Master Contract: 262247 Date Issued: 2020-07-21 DQD 507 Rev. 2019-04-30 © 2018 CSA Group. All rights reserved. Page 2 ZXM6-NO132-xxx/M, xxx=385 to 410, in step of 5 W ZXM6-NO120-xxx/M, xxx=350 to 375, in step of 5 W Models with 158.75 mm or 156.75 mm Cells ZXM6-NH156-xxx/M, xxx=420 to 440, in step of 5 W ZXM6-NH144-xxx/M, xxx=390 to 410, in step of 5 W ZXM6-NH132-xxx/M, xxx=355 to 375, in step of 5 W ZXM6-NH120-xxx/M, xxx=325 to 340, in step of 5 W ZXM6-NP156-xxx/M, xxx=420 to 440, in step of 5 W ZXM6-NP144-xxx/M, xxx=390 to 410, in step of 5 W ZXM6-NP132-xxx/M, xxx=355 to 375, in step of 5 W ZXM6-NP120-xxx/M, xxx=325 to 340, in step of 5 W ZXM6-NO156-xxx/M, xxx=420 to 440, in step of 5 W ZXM6-NO144-xxx/M, xxx=390 to 410, in step of 5 W ZXM6-NO132-xxx/M, xxx=355 to 375, in step of 5 W ZXM6-NO120-xxx/M, xxx=325 to 340, in step of 5 W ZXM6-78-xxx/M, xxx=400 to 430, in step of 5 W ZXM6-72-xxx/M, xxx=355 to 400, in step of 5 W ZXM6-66-xxx/M, xxx=340 to 365, in step of 5 W ZXM6-60-xxx/M, xxx=295 to 330, in step of 5 W Note: 1. All electrical data are shown as relative to standard test conditions (STC) (1 000 W/m2, (25 ± 2) °C, AM 1,5 according to IEC 60904-3). 2.Manufacturer’s stated tolerance is ±3% for Voc and Pm, and Isc. APPLICABLE REQUIREMENTS CAN/CSA-C22.2 No. 61730-1:19 Photovoltaic (PV) module safety qualification - Part 1: Requirements for construction CAN/CSA-C22.2 No. 61730-2:19 Photovoltaic (PV) module safety qualification - Part 2: Requirements for testing UL 61730-1:2017 Photovoltaic (PV) Module Safety Qualification - Part 1: Requirements for Construction UL 61730-2:2017 Photovoltaic (PV) Module Safety Qualification - Part 2: Requirements for Testing DQD 507 Rev. 2019-04-30 © 2018 CSA Group. All rights reserved. Page 1 Supplement to Certificate of Compliance Certificate: 80049804 Master Contract: 262247 The products listed, including the latest revision described below, are eligible to be marked in accordance with the referenced Certificate. Product Certification History Project Date Description 80049804 2020-07-21 Original certification Open Energy For All Features Description Hoymiles 2-in-1 microinverter can connect up to 2 panels at once and maximize the PV production of your installation. With the maximum DC voltage of 60 V, Hoymiles microinverter is a PV Rapid Shutdown Equipment and conforms with NEC-2017 and NEC-2020 Article 690.12 and CEC-2021 Sec 64-218. All of the three models listed are equipped with reactive power control and are compliant with IEEE 1547, UL 1741 and CA Rule21. Microinverter Datasheet HM-600N HM-700N HM-800N Region: North America V202108 © 2021 Hoymiles Power Electronics Inc. All rights reserved. hoymiles.com sales@hoymiles.com 01 02 03 Easy installation, just plug and play With Reactive Power Control, compliant with CA Rule 21 Compliant with U.S. NEC-2017&NEC-2020 690.12 rapid shutdown 05 04 External antenna for stronger communication with DTU High reliability, NEMA 6 (IP67) enclosure, 6000 V surge protection Model HM-600N HM-700N HM-800N Input Data (DC) Commonly used module power (W)240 to 405+280 to 470+320 to 540+ Maximum input voltage (V)60 MPPT voltage range (V)16-60 Start-up voltage (V)22 Maximum input current (A)2 × 11.5 2 × 11.5 2 × 12.5 Output Data (AC) Peak output power (VA) 600 700 800 Maximum continuous output power (VA)590 696 766 Maximum continuous output current (A)2.46 2.84 2.90 3.35 3.19 3.68 Nominal output voltage/range (V)1 240/211-264 208/183-228 240/211-264 208/183-228 240/211-264 208/183-228 Nominal frequency/range (Hz)1 60/55-65 Power factor (adjustable)>0.99 default 0.8 leading…0.8 lagging Total harmonic distortion <3% Maximum units per branch2 6 5 5 4 5 4 Efficiency CEC peak efficiency 96.7% CEC weighted efficiency 96.5% Nominal MPPT efficiency 99.8% Nighttime power consumption (mW) <50 Mechanical Data Ambient temperature range (°C)-40 to +65 Dimensions (W × H × D mm)250 × 170 × 28 Weight (kg)3 Enclosure rating Outdoor-NEMA 6 (IP67) Cooling Natural convection – No fans Features Communication 2.4GHz Proprietary RF (Nordic) Monitoring S-Miles Cloud3 Warranty Up to 25 years Compliance UL 1741, IEEE 1547, UL 1741 SA (240 Vac), CA Rule 21 (240 Vac), CSA C22.2 No. 107.1-16, FCC Part 15B, FCC Part 15C PV Rapid Shutdown Conforms with NEC-2017 and NEC-2020 Article 690.12 and CEC-2021 Sec 64-218 Rapid Shutdown of PV Systems Technical Specifications © 2021 Hoymiles Power Electronics Inc. All rights reserved. *1 Nominal voltage/frequency range can vary depending on local requirements. *2 Refer to local requirements for exact number of microinverters per branch. *3 Hoymiles Monitoring System. DQD 507 Rev 2019-04-30 © 2018 CSA Group. All rights reserved. Page 1 Certificate of Compliance Certificate: 80035475 Master Contract: 261002 Project: 80035475 Date Issued: 2020-04-03 Issued to: Hoymiles Converter Technology Co., Ltd. No.18 Kangjing Road, Hangzhou, Zhejiang 310015 China Attention: Xingyao Zhang The products listed below are eligible to bear the CSA Mark shown with adjacent indicators 'C' and 'US' for Canada and US or with adjacent indicator 'US' for US only or without either indicator for Canada only Issued by: Yang (Jason) Lei Yang (Jason) Lei PRODUCTS CLASS – C531109 - POWER SUPPLIES - Distributed Generation Power Systems Equipment CLASS – C531189 - POWER SUPPLIES - Distributed Generation-Power Systems Equipment - Certified to U.S. Standards Grid Support Utility Interactive Inverter, Model HM-500, HM-500T, HM-600, HM -600T, HM-700, HM-700T, HM-800, HM-800T, HM-500N, HM-500NT, HM-600N, HM-600NT, HM-700N, HM-700NT, HM-800N, HM - 800NT, rack mounted. For details related to rating, size, configuration, etc., reference should be made to the CSA Certification Record, Certificate of Compliance Annex A, or the Descriptive Report. *Note: This product is PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 Article 690.12 and CEC-2018 Sec 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according to manufacturer’s instructions. Certificate: 80035475 Project: 80035475 Master Contract: 261002 Date Issued: 2020-04-03 DQD 507 Rev 201 9-04-30 © 2018 CSA Group. All rights reserved. Page 2 APPLICABLE REQUIREMENTS CSA-C22.2 No. 107.1-16 - Power Conversion Equipment *UL Std. No. 1741 - Inverters, Converters, Controllers and Interconnection System Equipment for Use With Distributed Energy Resources (Second Edition, Revision dated February 15, 2018). *Note: Conformity to UL 1741-Second Edition (February 15, 2018) includes compliance with applicable requirements of IEEE 1547-2003(R2008) and IEEE 1547.1-2005 (R2011) and California Rule 21 and Supplement SA. Open Energy For All Features Description Hoymiles 4-in-1 microinverter is one of the most cost-effective module-level solar solutions, as it can support up to 4 panels at once and maximize the PV production of your installation. With the maximum DC voltage of 60 V, Hoymiles microinverter is a PV Rapid Shutdown Equipment and conforms with NEC-2017 and NEC-2020 Article 690.12 and CEC-2021 Sec 64-218. All of the three models listed are equipped with reactive power control and are compliant with IEEE 1547, UL 1741 and CA Rule21. Microinverter Datasheet HM-1200N HM-1500N Region: North America V202108 © 2021 Hoymiles Power Electronics Inc. All rights reserved. hoymiles.com sales@hoymiles.com 01 02 03 Easy installation, just plug and play With Reactive Power Control, compliant with CA Rule 21 Compliant with U.S. NEC-2017&NEC-2020 690.12 rapid shutdown 05 04 External antenna for stronger communication with DTU High reliability, NEMA 6 (IP67) enclosure, 6000 V surge protection Model HM-1200N HM-1500N Input Data (DC) Commonly used module power (W)240 to 405+300 to 505+ Maximum input voltage (V)60 MPPT voltage range (V)16-60 Start-up voltage (V)22 Maximum input current (A)4 × 11.5 4 × 11.5 Output Data (AC) Peak output power (VA) 1260 1200 1500 1350 Maximum continuous output power (VA)1200 1109 1438 1246 Maximum continuous output current (A)5 5.33 5.99 5.99 Nominal output voltage/range (V)1 240/211-264 208/183-228 240/211-264 208/183-228 Nominal frequency/range (Hz)1 60/55-65 Power factor (adjustable)>0.99 default 0.8 leading…0.8 lagging Total harmonic distortion <3% Maximum units per branch2 3 3 2 2 Efficiency CEC peak efficiency 96.7% CEC weighted efficiency 96.5% Nominal MPPT efficiency 99.8% Nighttime power consumption (mW) <50 Mechanical Data Ambient temperature range (°C)-40 to +65 Dimensions (W × H × D mm)280 × 176 × 33 Weight (kg)3.75 Enclosure rating Outdoor-NEMA 6 (IP67) Cooling Natural convection – No fans Features Communication 2.4GHz Proprietary RF (Nordic) Monitoring S-Miles Cloud3 Warranty Up to 25 years Compliance UL 1741, IEEE 1547, UL 1741 SA (240 Vac), CA Rule 21 (240 Vac), CSA C22.2 No. 107.1-16, FCC Part 15B, FCC Part 15C PV Rapid Shutdown Conforms with NEC-2017 and NEC-2020 Article 690.12 and CEC-2021 Sec 64-218 Rapid Shutdown of PV Systems Technical Specifications © 2021 Hoymiles Power Electronics Inc. All rights reserved. *1 Nominal voltage/frequency range can vary depending on local requirements. *2 Refer to local requirements for exact number of microinverters per branch. *3 Hoymiles Monitoring System. DQD 507 Rev. 2019-04-30 Page 1 Certificate of Compliance Certificate: 80017010 Master Contract: 261002 Project: 80036969 Date Issued: 2020-03-12 Issued to: Hoymiles Converter Technology Co., Ltd. No.18 Kangjing Road, Hangzhou, Zhejiang 310015 CHINA Attention: Xingyao Zhang The products listed below are eligible to bear the CSA Mark shown with adjacent indicators 'C' and 'US' for Canada and US or with adjacent indicator 'US' for US only or without either indicator for Canada only. Issued by: Yang (Jason) Lei Yang (Jason) Lei PRODUCTS CLASS - C531109 - POWER SUPPLIES-Distributed Generation Power Systems Equipment CLASS - C531189 - POWER SUPPLIES - Distributed Generation-Power Systems Equipment - Certified to U.S. Standards Grid Support Utility Interactive Inverter, Model HM-1500, HM-1500T, HM-1200, HM-1200T, HM-1000 and HM-1000T, THM-1500, HM-1500N, HM-1500NT, HM-1200N, HM-1200NT, HM-1000N and HM-1000NT, rack mounted. For details related to rating, size, configuration, etc., reference should be made to the CSA Certification Record, Certificate of Compliance Annex A, or the Descriptive Report. *Note: This product is PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 Article 690.12 and CEC-2018 Sec 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according manufacturer¶s instructions. Certificate: 80017010 Project: 80036969 Master Contract: 261002 Date Issued: 2020-03-12 DQD 507 Rev. 2019-04-30 Page 2 APPLICABLE REQUIREMENTS CSA-C22.2 No. 107.1-16 - Power Conversion Equipment *UL Std. No. 1741 - Inverters, Converters, Controllers and Interconnection System Equipment for Use With Distributed Energy Resources (Second Edition, Revision dated February 15, 2018) *Note: Conformity to UL 1741-Second Edition (February 15, 2018) includes compliance with applicable requirements of IEEE 1547-2003(R2008) , IEEE 1547.1-2005 (R2011) and California Rule 21 and Supplement SA. AL Roof Hook 019 CHIKO L Feet matching to the Flashing,supplying the best waterproofing solution for Asphalt Shingles Roofs. Enables simple, fast and cost-effective installation High class anodized aluminium. Fasteners and rail nut configurated to save extra parts purchasing. 100% water proofing. PRODUCT LINE Item CK-FTH-211 Product Name CHIKO AL Roof Hook 211 ORDERING SPECIFICS Standard Packaging Dimensions Weight 16PCS/CTN 34X25X7CM 6KG www.chikolar.com/www.chikosolar.com Phone:86-21-59972267-801 Fax:86-21-59972938 ADVANTAGES TECHNICAL DATA Main Material Uplift P Wind Load Snow Load Hook Spacing Installation Site 6005-T5 & SUS304 N*Fvč N=3Ď Up to 60 M/S 1.4 KM/M2 Up to 2000mm Roman Tile Roof COMPONENT LIST MATERIAL AL Flashing AL L Feet 050 Nut SUS Bolt M8*25 SUS M8 Wahser Wooden Screw M8*90 Silicon Rubber QTY 01 01 01 01 02 01 01 85WARRANTY UL LISTED 7 RAIL CHIKO 7R aluminium rail is designed for roof mounting system, it could applied on all roof mount system. PRODUCT LINE Item CK-7R-2100 CK-7R-3200 CK-7R-4200 Product Name CHIKO 7 RAIL 2100MM CHIKO 7 RAIL 3200MM CHIKO 7 RAIL 4200MM TECHNICAL DATA Main Material Wind Velocity Xi=31918.082 mm4 Yi=81501.592 mm4 AL 6005-T5 Up to 60 M/S ORDERING SPECIFICS Standard Packaging Dimensions Weight 8 PCS/PKG 2100/3200/4200mm 15/22.8/30KG COMPONENT LIST WARRANTY MATERIAL Aluminium Rail QTY 01 www.chikolar.com/www.chikosolar.com Phone:86-21-59972267-801 Fax:86-21-59972938 Easy installation Highclass anodized Tilt- in nut Universal on roof mount system ADVANTAGES UL LISTED 7 RAIL SPLICE KIT CHIKO 7R aluminium rail splice kit is designed for 7R rail connection from back to position. The most simple and handy installation way. PRODUCT LINE Item CK-FT-SKA Product Name CHIKO 7 Rail Splice Kit TECHNICAL DATA Main Material Wind Load Snow Load AL 6005-T5 Up to 60 M/S 1.4 KM/M2 ORDERING SPECIFICS Standard Packaging Dimensions Weight 200 PCS/PKG 51X38X22CM 30KG www.chikolar.com/www.chikosolar.com Phone:86-21-59972267-801 Fax:86-21-59972938 200m m 45.7mm Easy installation Highclass anodized COMPONENT LIST MATERIAL Aluminium Rail Splice Kit SUS304 Bolt M8*25 Star Washer QTY 01 02 02 WARRANTYADVANTAGES UL LISTED Intergated Grounding Mid Clamp CHIKO end clamps is designed base on 7R rail to fix module on the end of rail, have founction of intergated grounding, 30mm to 50 mm thickness module are available. PRODUCT LINE Item CK-FTM-K30 CK-FTM-K33 CK-FTM-K35 CK-FTM-K38 CK-FTM-K40  Product Name CHIKO Intergated Grounding Mid Clamp 30mm CHIKO Intergated Grounding Mid Clamp 33mm CHIKO Intergated Grounding Mid Clamp 35mm CHIKO Intergated Grounding Mid Clamp 38mm CHIKO Intergated Grounding Mid Clamp 40mm COMPONENT LIST WARRANTY MATERIAL Mid Clamp SUS304 Bolt M8 050 SUS304 Nut Rivet Intergated Grounding Easy installation High class anodized Tilt- in nut TECHNICAL DATA Main Material AL 6005-T5 QTY 01 01 01 02 ORDERING SPECIFICS Standard Packaging Dimensions Weight 100 PCS/BOX 400PCS/CTN 50X38X20CM 26.8/27.5/28/28.6KG D=30/33/35/38/40/45/50 www.chikolar.com/www.chikousa.com Phone:86-21-59972267-801 Fax:86-21-59972938 ADVANTAGES UL LISTED Intergated Grounding End Clamp CHIKO end clamps is designed base on 7R rail to fix module on the end of rail, have founction of intergated grounding, 30mm to 50mm thickness module are available. Intergated Grounding Easy installation High class anodized Tilt- in nut ADVANTAGES UL LISTED PRODUCT LINE Item CK-FTE-K30 CK-FTE-K33 CK-FTE-K35 CK-FTE-K38 CK-FTE-K40 ... Product Name CHIKO Intergated Grounding End Clamp 30mm CHIKO Intergated Grounding End Clamp 33mm CHIKO Intergated Grounding End Clamp 35mm CHIKO Intergated Grounding End Clamp 38mm CHIKO Intergated Grounding End Clamp 40mm TECHNICAL DATA ORDERING SPECIFICS Standard Packaging Dimensions Weight 100 PCS/BOX 400PCS/CTN 50X38X20CM 22/24.5/25.5/26KG COMPONENT LIST WARRANTY MATERIAL End Clamp SUS304 Bolt M8*25 SUS304 Washer M8 050 SUS304 Nut Rivet QTY 01 01 01 01 01 Main Material AL 6005-T5 D=30/33/35/38/40/45/50 www.chikolar.com/www.chikousa.com Phone:86-21-59972267-801 Fax:86-21-59972938 www.roof-tech.us info@roof-tech.us RT-MINI II RT-MINI II is suitable for all systems with any L-Foot ICC ESR 3575Installation Manual RT Serrated Hex Flange Bolt/Nut:5/16-18 x 1” A Self-flashing PV Mount Featuring Roof Tech s AlphaSeal™ Technology Wide Range of Applications & UltimateFlexibility on the Roof No Need to Bend Rails1 5/8 North & South Adjustment No Caulking or Pre-Drilling Required Metal, EPDM, TPO, SBS, & Asphalt Roofs b Conduit Strap Installation Universal Attachment to Any Slope RT-MINI II Flexible Flashing Certified by the International Code Council (ICC) Components MINI II base : 20 ea. Screw : 40 ea. Extra RT-Butyl : 4 ea. Roof Tech Inc. AlphaSeal™ Technology has been used on over one million residential PV systems since 1994. It is the first PV mounting system with Flexible Flashing certified by the ICC, engineered to withstand wind speeds up to 180 mph and ground snow up to 90 psf. ICC ESR-3575 ASTM2140 Testing www.roof-tech.us info@roof-tech.us 10620 Treena Street, Suite 230, San Diego, CA 92131858.935.6064 Roof Tech Inc. Flexible Flashing 100% Waterproof Metal Flashing Retrofit Shedding Water? Rafter InstallationDeck Installation ’ Dimensions in (mm) Optional Items: 5 x 60mm Mounting Screw (RT2-04-SD5-60) : 100 ea./Bag 5/16 X 25MM Flange Bolt & Nut (RT2-04-FBN25) : 100 ea./Bag RT-Butyl (RT2-04-MNBUTYL) : 10 ea./BoxPatent# D822459 3.54 inch (90mm).60 inch (15.4mm) RT2-00-MINIBK2 Offset Rafter Installation Offset Rafter Attachment Options‘ August 2022 OSB & PLY Hybrid Mounting Support & Downloads P.E. Letters Engineered to ASTM D 1761(Standard Test Methods for Mechanical Fasteners in Wood) Subject: Proposed Solar Panel Installation William Cortani III Residence, 1831 W 13th St, Port Angeles, WA To Whom it May Concern, Design Parameter Summary Governing Building Code: 2018 Washington Building Code (2018 IBC) Risk Category: II Design Wind Speed: 110 mph (per ASCE 7-16) Ground Snow Load: 15 psf Roof Information Roof Structure: 2x4 Manufactured Trusses @ 24" O.C. Roofing Material: Asphalt Shingles (1 layer) Roof Slope: 22 degrees Note: Required embedment length excludes the tapered tip of the screw, and embedment into sheathing. Roof Connection Details Our engineering department has reviewed information, gathered by our field crews, related to the proposed solar panel installation at the above-referenced address. The purpose of our review was to determine the structural adequacy of the existing roof. Based on our review and analysis of the available information, and in accordance with governing building codes, it is our professional opinion that the existing structure is permitted to remain unaltered for the proposed solar installation. Wind uplift on the panels has been calculated in accordance with the relevant provisions of ASCE 7-16. This loading has been used to verify the adequacy of the connection specified above. Connection locations should be in accordance with design drawings. Locations per design drawings August 12, 2023 Analysis The proposed installation complies with the requirements of WAC Section 51-51-03240 R324.4 (Exception) and is therefore deemed adequate to support the load of the rooftop solar system. RT Minis. Install generally into 2x rafters/chords, but up to 50% may be installed into decking only. 48" O.C.. Install Specifically: 1) the system is designed for the local wind speed; 2) the ground snow load does not exceed 70 psf; 3) the total dead load of all items is less than 4 psf (actual value is approximately2.74 psf); 4) Modules are not mounted more than 18" off the roof; and 5) Supports are installed such that the dead load is spread across roof- framing members and does not exceed 50 lbs at any point. Sincerely, Trevor A. Jones, P.E. Limitations and Disclaimers 12/08/2023 If you have any questions or concerns, please contact our office at (855)-709-1181, or email me directly at Trevor.Jones@solgenpower.com. Electrical engineering is beyond the scope of this analysis. Solar panels must be installed per manufacturer specifications. Structural design and analysis of the adequacy of solar panels, racks, mounts, rails, and other components is performed by each component's respective manufacturer and the undersigned makes no statement of opinion regarding such components. This letter and the opinions expressed herein are rendered solely for the benefit of the permitting authority (city or county building department), and may not be utilized or relied on by any other party. The opinion expressed in this letter is made in reliance on the following assumptions: the existing structure is in good condition; the existing structure is free from defects in design or workmanship; and the existing structure was code-compliant at the time of its design and construction. These assumptions have not been independently verified, and we have relied on representations made by the property owner and his or her agents with respect to the foregoing. The undersigned has not inspected the structure for patent or latent defects. The roof structure need not be altered for either gravity or lateral loading. Therefore, the existing structure is permitted to remain unaltered. Connections to the roof must be made per the "Roof Connection Details" section above. Copies of all relevant calculations are enclosed. Conclusion WA State Exception Criteria - Calculation Connection Demand Spacing perpendicular to rail 32.5 in 1/2 panel length Spacing parallel to rail 48 in Max spacing Solar Dead Load 2.74 psf Solar DL Point Load 29.68333333 lbs OK This calculation justifies the additional solar load by showing the solar dead load at each attachment is less than 50 lbs (WAC 51-51-03240, R324.4, Exception Criteria). RT Mini Connection Calculation Connection Demand Spacing perpendicular to rail 32.5 in (1/2 panel length) Roof Angle 22 degrees Roof Type Gable Wind Speed 110 mph Topographic Factor, Kzt 1 Directionality Factor, Kd 0.85 Elevation Factor, Ke 0.99 Velocity Pressure, qz 22.2 psf Zone 1 Zone 2r Zone 3 Spacing parallel to rail 48 48 48 in (max) Effective Wind Area on each connection 10.8 10.8 10.8 ft2 GCp (max)1.90 1.97 1.97 Exposed Panels? (γE = 1.5)No No No Pressure Equalization Factor, γa 0.79 0.79 0.79 Uplift Force 33.1 34.4 34.4 psf Max. Uplift Force / Connection (1.0 WL)358.3 372.8 372.8 lbs ASD Factored (0.6 WL)215.0 223.7 223.7 lbs Solar Dead Load (0.6 DL)17.8 17.8 17.8 lbs Max. Uplift Force (0.6 WL - 0.6 DL)197.1 205.8 205.8 lbs Connection Capacity Connection Type RT Mini (50/50 Deck and Rafter Mounts) Total Allowable Capacity 313.5 lbs (per manufacturer) Compare ASD Factored Demand to Capacity Demand 205.8 lbs Capacity 313.5 lbs Result This calculation justifies the connection of the solar panels to existing roof members, by showing the connection capacity is equal to or greater than the uplift force demands. Minimum embedment is 1.5 inches, Capacity exceeds demands. Therefore, connection passes. ELECTRICAL INSPECTION WIRING REPORT APPROVED NOT APPROVED DITCH ROUGH IN/COVER SERVICE FINAL COMMENTS NOTIFY INSPECTOR at (360) 808-2613 WHEN CORRECTIONS ARE COMPLETED WITHIN 15 DAYS DATE PERMIT # INSPECTOR 1/3/2024 23-1273 TAP OWNER CONTRACTOR Solgen Power PROJECT ADDRESS 1831 W 13th St