HomeMy WebLinkAbout305 S Albert St - Building . CITY OF PORT AOOELEs" LIGHT DEPARTMENT 321 E. Fifth Street Port Angeles. WA 98362 (206) 457-0411 PERMIT NO. _ s.3 eo /t9k/7s'" DATE ELECTRICAL PERMIT Inst lied By: o READY FOR INSPECTION License Number: o WILL CALL FOR INSPECTION Phone: Site ddress: Own r/Business: Phone: Own r/Business Address: Sq. Ft. ELE RIC HEAT o B;t\SEBOARD KW _ o FURNACE KW _ o H!EAT PUMP KW o F N/WALL KW _ ~ RESIDENTIAL o COMMERCIAL o NEW CONSTRUCTION o REMODEL ~ ADD/ALTER CIRCUITS o SERVICE UPGRADE/REPAIR o TEMPORARY SERVICE o RISER o OVERHEAD SERVICE o UNDERGROUND SERVICE VOLTAGE: D1~ D3~ SERVICE SIZE FEEDER SIZE AMPS AMPS Deta.lslDescription: . W.S. o. SERVICE SIZE CAP CITY: O.K. 0 NOT O.K. ACTI N REQUIRED: 0 CHANGE TRANSFORMER o INSTALL SERVICE POLE DATE ENGR. o OVERHEAD SERVICE APPROVED o CHANGE SERVICE WIRE o OTHER o Di ch Inspection O.K. o R ugh-in/cover O.K. o O. . to connect service Ay)p Fi al O.K. Instal ee Permit/Receipt No. S30D Site ddress: New Meters _. . Notify Port Angele ity Light by Street Address and Permit Number when ready tor inspection. Work must not be covered betor inspection and O.K. tor covering has been given by the electrical inspector in writing on either the Wiring Report or on he Buildin Pe . PHONE 457-0411, EXT. 224. $ao NO OCCUPANCY OR USE ESTABLISHED UNDER TH!S PERMIT H- $ Electrical Inspector Permit Fee WHITE File by address PINK ~ Top: Eng, Bottom, Customer GREEN - Top: Meter Dept.. Bottom: City Hall OLYMPIC P INTERS INC. ~--" W ~/AAN Gr Gv1~ PORT ANGELES HOUSING REHABILITATION PROGRAM . 129 E 1st St Port Angeles, WA 98362 " Telephone #452-2@23 ;, ...J,.o. .' ~ , Date: June 9, 1995 (revised July 24 and September 20, 1995) Final wotklist specifications for: Walter and Dora Johnson (95PA02) 30~ South Albert Port Angeles, WA 98363 t~\P1 Telephone #457-7350 SELECTED CONTRACTOR: Cozi Homes Construction 329 E 9th Port Angeles, WA 98362 Telephone #452-9906 PROJECT A (REQUIRED HEALTH AND SAFETY REPAIRS) I 0600 ~ l)Rear porch: Remove the existing decking and install pressure treated decking. Stain and fin~sh or paint deck surface. Include installation of ~ mil vapor under porch area. new 2x6 the new barrier 2)Rear porch: Install new treads, risers, and steps to match existing width. Include installation of a new concrete pad at base of steps (approx. 3'x6' r and hand railing on each end of steps. Stain and finish or paint the steps and railing. 0800 l)NE bedroom: Modify the window opening on the north wall and install a new vinyl framed single hung window with insulating glass. Trim and finish the interior and exterior. Stain and finish or paint the trim. Note: this must be a proper egress window. 2)North center bedroom: Modify the window opening on the north wall and install a new vinyl framed single hung window with insulating glass. Trim and finish the interior and exterior. Stain and finish or paint the trim. Note: this must be a proper egress window. .~ , <F' 1 C\x q~ l1J\J/]:r' \() cJ1'tJ 0~r-{3 1/ t7 (J . 'j .... /\ PROJECT C (EXTERIOR DETERIORATION AND BLIGHTING) 9'- -~-'j.S 0400/0600 l)Excavate the crawl space to 18"' and install new .concrete footinqs and foundation around the perimeter o~.the house. ~emove all ~ebris in the crawl space and elimin~te earth/wood contact .throuqhout. Remove/-replace deteriorated and framinq and install proper footinqs, support posts, framinq necessary to properly support the house. Complete extermination of powder post beetles and other wo6d destroyinq insects ~nd orqanisms. Include removal and re-installation of existinq crawl space insulation. Install a 6-mil poly vapor barrier. i,. posts' and ~ Note: all work to be recommenda ti ons of Para tex. ( attached). completed in accordance wi th the outlined in the report of June 13, 1995 0700 1) Repair/replace sidinq corners around the perimeter of the house. PROJECT D (COST EFFECTIVE ENERGY CONSERVATION) 0600 l)Rear porch/utility. Install a new dryer vent with back draft damper. (refer to pest inspection report) ~ PROJECT E (BUILDING CONSERVATION) 1800 1) Properly prepare and paint the exterior wood surfaces. InclUde all exposed wood trim and soffit areas. Attention contractors: Please bid all projects separately. Include app,Zicable tax and permit fees. 1 . I ~ f\~ ,\~ ~~r 3 CITY OF PORT ANGELES LIGHT DEPARTMENT ELECTRICAL PERMIT N? 15034 '1- / -.- "9"' Port Angeles, Washlngton.........:no.....mm:m..mm..m.mmmmm.m.. 19...~m In accordance with the City Ordinance to regulate the Installation. extension, or repair of elec- trical equipment In. on, or about any building or other structure in the City of Port Angeles, per- mIssion is hereby granted to do electrical work as listed below. ACldress ..m.:~':m.~.......f~......:.:m'~:~:...~..~~d:.m..m......nommmm.... Occupancyno....M..1L...mm..m.m........... _ ' I" ,; r Owner _.__u.__,..!~.~~_~~~:':!~..,t-;-~--~~-z-,!.;~..~~.---..nnn..h------.- Tenant..______un_.....uh__uuu_____n_u______..nn_n___.___nn__._un Wiring Contractor ..::!:(..;.:..,.,,-'.'..:L..~.m.......mm...m............ By............nono...m....m.mm.........................no.... Light Outlets.......................................... Service, volts ;12..0..(.-2.'!...(........ Type of WIring: Receptacle Outletsnnm_................._n... No. wires m_m.h)_nnm_.m___.........._.. Size wiresm___//(.2r2.~_~_..._..._.. .QO .4 Main fuse m__......nm....:....._hmm.... Enclosure ....n_~>....._.hnh.._..._mm_n Type of Wiring: Entrance Cable ._mm__mm__._..m.... Dryer, KWI..no..........................no........ Runge, KW __n...mm..hn__mm__ Water Heater: KW...................... .................. Hea,: Rw../(~.~.?.(.fJ...4..... Rigid Conduit Motors: size, volts and phase: Metallic Tubing m___.._m__m___..__... Current transformers: No. & Size._.__n.....nn__...n................ Ser. NO.........._n_.....n......_......._.._...... Ser. NO......_.................._..n..__nnn.__. Ser. No...................__....._..._.._.._._____... Armored Cable .m_...n._m..m_m__.... Non-Metallic .m.mm.mnmn___m..... Knob & Tubem__...m_.m._................ Rigid Conduit ....._......____.....mm_.._ Metallic Tubing mnnnmmnhm..... Raceway _____.._....___......_...............__._ Circuits, LighLnmmmumn...mmmnn... Utility........................................... Heat _____.3___c:.-!.-..._................_... Range ___._______.__.____.___..._.____............. Water Heater ...._........__.._............. ]"Iotor ..._...___.......__..............____.__00_. Dryer_.______n_______.___________.._____...____...._ Furnace n..____........_._..__............n........ Total I-oadunu_._....u_...__....... Ser. NO........._._.u...._~.__..............._d..._ Total ..____...00____00000000_......___.00__. Remarks: .........:2\.~?...:..'.=....m......9..~.._"<.ml'.....'..<.~'~m~I..:...m........................m.m.........m........mm...... l?ermit Fee Treas. Receipt ,7 / ,j . ~;' . / / $...................................... NO......m.................... By m.L....':.:........~:.L~!..!.:...:..:..,:.L.............'--.. NOTICE-Current must not be turned on until Certificate of Inspection has been issued. It work is to be con. c;ealed due noUce must be given the Inspector so that work may be Inspected before concealment. NOTIFY THE INSPECTOR BY PERMIT NUMBER WHEN READY FOR INSPECTION -;2, /(1/;;:/ 1ft", B B ELECTRICAL PERMIT N? 15034 . / ,,; pate called fo0t.~{v/~.i.h'~~.:...~h.....h....hh.-.................h........m..h..h.......h...-/...~.!.....).....=.__:..'(..................... preliminary .inspection dates____'.::.!...nn......n..._._...n.h...nn_.n 0000_.00_ n....... _dd__.n. 00_ ...........n___n..U.___d...._........ . '/ 00___00_..._...-......--......... Jnspectjonc()mpleted__._~~::.~.!::..~.::.-:~:::~.c:-:...........-................_....._._..._....._..___u____._...........__.__.___............_..____.._...........__.....___...__..___.____ \ Total Load u..nnn..nn______._.............................h.h..............n_nn_._._nu_ ... \ 1M 3-72 Olympic Printers, Inc.