Loading...
HomeMy WebLinkAbout110 N Alder St - BuildingCERTI This certificate is issue cert wing that at the t regulating building c Business name Business address Property owner Property owner s add Automatic fire spri Use occupancy cl` Building permit numb Type of construction. Occupant load. ursuant to the requirements of Section 110 of the 20 e of ass �ance tli struct re was in compliance with the v nstru ?tion orfiuse f or gay ress er .system. NtgAlt asst cation. WCd�l er. 29 Post on the premises in a conspicuous place. This S and Comm'uni' Alder St. Gale P o ofirl 560 S E MawayBlud Not Required Business Hager UPANCY ision International Building Code ious ordinances of the City 277 5018 07 -31 -09 Date erfi'•ffEa" hall not•bei emoved except by the Building Official. 0 140,rne cvwv t,e) c 14, Issue Date Expiration Date Parcel Number Property Address Subdivision Name Legal Description Property Zoning Owner Contractor Approved CITY OF PORT ANGELES 321 E 5TH STREET P 0 BOX 1150 PORT ANGELES WA 98362 C E R T I F I C A T E /P6 O F O C C U P A N C Y T E M P O R A R Y 7/13/09 8/13/09 06-30-00-5-6- 0125 -0000- 110 N ALDER ST PORT ANGELES WA 98362 CARTER'S, THOMAS W SUBDIVISION LT16- 17 &PT18 SUR V10P140 BL13 2 SURVEY V41 P65 COMMERCIAL ARTERIAL GALE P QUINN GOLDEN HOME SERVICES INC 360 782 -4829 Application number Description of Work Construction type Occupancy type Flood Zone 08- 00001492 000 000 COMM NEW CONST uilding 0 Special conditions July 13, 2009 10 38 18 AM jler /ly Finish rear landin n north si e exit /aaa tactile signs mounted /exit sign oanted andsible/ to occupy VOID UNLESS SIGNED BUILDING OFFICIAL PREPARED 7/10/09 9 41 54 INSPECTION TICKET PAGE 4 CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 7/10/09 ADDRESS 110 N ALDER ST SUBDIV TENANT NBR SOUND COMMUNITY BANK CONTRACTOR TUBE ART DISPLAYS INC PHONE (206) 223 1122 OWNER GALE P QUINN PHONE PARCEL 06 30 00 5 6 0125 0000 APPL NUMBER 09 00000426 SIGNS PERMIT SIGN 00 SIGN REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS BL99 01 7/10/09 JLL BLDG FINAL TIME 01 00 7/ July 8 2009 4 30 26 PM 1pangrle LANCE 360 782 4829 BLDG FINAL TWO FREESTANDING SIGNS (SOUND COMMUNITY BANK) AFTERNOON L C COMMENTS AND NOTES PREPARED 7/10/09 9 41 54 INSPECTION TICKET PAGE 2 CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 7/10/09 ADDRESS 110 N ALDER ST SUBDIV TENANT NBR SOUND COMMUNITY BANK CONTRACTOR GOLDEN HOME SERVICES INC PHONE (360) 782 4829 OWNER GALE P QUINN PHONE PARCEL 06 30 00 5 6 0125 0000 APPL NUMBER 08 00001492 COMM NEW CONST REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS 5/07/09 AP May 6 2009 4 54 09 PM 1pangrle LANCE 360 782 4829 REBAR HE WANTS TO BE YOUR LAST INSPECTION OF THE DAY May 7 2009 4 10 42 PM jlierly FFNL 01 7/07/09 KDD FIRE FINAL 7/07/09 AP July 7 2009 1 57 31 PM kdubuc Fire final July 7 2009 1 58 33 PM kdubuc Fire final PW99 01 7/07/09 RV PUBLIC WORKS FINAL 7/07/09 AP July 7 2009 11 36 05 AM rvess July 7 2009 11 36 47 AM rvess BL99 01 7/10/09 JLL BLDG FINAL TIME 01 00 ,a July 8 2009 4 31 36 PM 1pangrle LANCE 360 782 4829 V� BLDG FINAL SOUND COMMUNITY BANK BLDG AFTERNOON PERMIT ME 00 MECHANICAL PERMIT f/ REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS ME1 01 4/16/09 JLL MECHANICAL ROUGH IN 4/17/09 AP April 16 2009 8 46 15 AM 1pangrle LANCE 360 782 4829 MECHANICAL ROUGH IN April 17 2009 4 16 00 PM jlierly ME99 01 7/10/09 JLL MECHANICAL FINAL TIME 01 00 July 8 2009 4 32 34 PM 1pangrle ---T =7-74-29 LANCE 360 782 4829 MECHANICAL FINAL SOUND COMMUNITY BANK BLDG AFTERNOON PERMIT PL 00 PLUMBING PERMIT REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS PL2 01 3/24/09 PB PLUMBING ROUGH IN TIME 01 00 3/25/09 AP March 23 2009 2 53 02 PM 1pangrle DOUG 457 1690 ROUGH IN PLUMBING AFTERNOON March 25 2009 8 17 43 AM pbarthol PL99 01 7/10/09 JL PLUMBING FINAL TIME 01 00 July 8 2009 4 33 12 PM 1pangrle LANCE 360 782 4829 PLUMBING FINAL SOUND COMMUNITY BANK BLDG AFTERNOON COMMENTS AND NOTES ice-7° PREPARED 7/30/09 8 29 23 INSPECTION TICKET PAGE 2 CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 7/30/09 ADDRESS 110 N ALDER ST SUBDIV TENANT NBR SOUND COMMUNITY BANK CONTRACTOR GOLDEN HOME SERVICES INC PHONE (360) 782 4829 OWNER GALE P QUINN PHONE PARCEL 06 30 00 5 6 0125 0000 APPL NUMBER 08 00001492 COMM NEW CONST REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS 5/07/09 AP May 6 2009 4 54 09 PM 1pangrle LANCE 360 782 4829 REBAR HE WANTS TO BE YOUR LAST INSPECTION OF THE DAY May 7 2009 4 10 42 PM jlierly FFNL 01 7/07/09 KDD FIRE FINAL 7/07/09 AP July 7 2009 1 57 31 PM kdubuc Fire final July 7 2009 1 58 33 PM kdubuc Fire final PW99 01 7/07/09 RV PUBLIC WORKS FINAL 7/07/09 AP July 7 2009 11 36 05 AM rvess July 7 2009 11 36 47 AM rvess BL99 01 7/10/09 JLL BLDG FINAL TIME 01 00 7/13/09 DA July 8 2009 4 31 36 PM 1pangrle LANCE 360 782 4829 BLDG FINAL SOUND COMMUNITY BANK BLDG AFTERNOON July 13 2009 9 34 10 AM pbarthol BL99 02 7/30/09 !I` BLDG FINAL TIME 01 00 July 29 2009 4 32 07 PM 1pangrle LANCE 360 782 4829 BLDG FINAL SOUND COMMUNITY BANK AFTERNOON PERMIT ME 00 MECHANICAL PERMIT REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS ME1 01 4/16/09 JLL MECHANICAL ROUGH IN 4/17/09 AP April 16 2009 8 46 15 AM 1pangrle LANCE 360 782 4829 MECHANICAL ROUGH IN April 17 2009 4 16 00 PM jlierly ME99 01 7/10/09 JLL MECHANICAL FINAL TIME 01 00 7/13/09 DA July 8 2009 4 32 34 PM 1pangrle LANCE 360 782 4829 MECHANICAL FINAL SOUND COMMUNITY BANK BLDG AFTERNOON July 13 2009 9 34 10 AM pbarthol ME99 02 7/30/09 JLL' MECHANICAL FINAL TIME 01 00 July 29 2009 4 33 11 PM 1pangrle LANCE 360 782 4829 MECHANICAL FINAL SOUND COMMUNITY BANK AFTERNOON PERMIT PL 00 PLUMBING PERMIT REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS PL2 01 3/24/09 PB PLUMBING ROUGH IN TIME 01 00 CONTINUED ONTO NEXT PAGE PREPARED 7/30/09 8 29 23 INSPECTION TICKET PAGE 3 CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 7/30/09 ADDRESS 110 N ALDER ST SUBDIV TENANT NBR SOUND COMMUNITY BANK CONTRACTOR GOLDEN HOME SERVICES INC PHONE (360) 782 4829 OWNER GALE P QUINN PHONE PARCEL 06 30 00 5 6 0125 0000 APPL NUMBER 08 00001492 COMM NEW CONST REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS 3/25/09 AP March 23 2009 2 53 02 PM 1pangrle DOUG 457 1690 ROUGH IN PLUMBING AFTERNOON March 25 2009 8 17 43 AM pbarthol PLUMBING FINAL TIME 01 00 July 8 2009 4 33 12 PM 1pangrle LANCE 360 782 4829 PLUMBING FINAL SOUND COMMUNITY BANK BLDG AFTERNOON July 13 2009 9 34 10 AM pbarthol PL99 02 7/30/09 iL PLUMBING FINAL TIME 01 00 July 29 2009 4 33 47 PM 1pangrle Ct II 'P LANCE 360 782 4829 PLUMBING FINAL SOUND COMMUNITY BANK AFTERNOON PL99 01 7/10/09 JLL 7/13/09 DA COMMENTS AND NOTES PREPARED 7/10/09 9 41 54 INSPECTION TICKET PAGE 3 CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 7/10/09 ADDRESS 110 N ALDER ST SUBDIV TENANT NBR SOUND COMMUNITY BANK CONTRACTOR GOLDEN HOME SERVICES INC PHONE (360) 782 4829 OWNER GALE P QUINN PHONE (360) 675 5859 PARCEL 06 30 00 5 6 0125 0000 APPL NUMBER 09 00000139 COMM NEW CONST PERMIT BPC 00 BUILDING PERMIT COMMRRCIAL REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS BL3 01 5/18/09 JLL BLDG FRAMING TIME 01 00 5/18/09 AP May 15 2009 8 20 34 AM 1pangrle LANCE 360 782 4829 FRAMING AFTERNOON May 18 2009 4 26 34 PM jlierly BLI 01 5/28/09 JLL BLDG INSULATION 5/28/09 AP May 28 2009 8 22 27 AM 1pangrle LANCE 360 782 4829 INSULATION HE REQUESTED A MORNING INSPECTION May 28 2009 4 13 34 PM jlierly PW99 01 7/07/09 RV PUBLIC WORKS FINAL 7/07/09 AP July 7 2009 11 37 30 AM rvess July 7 2009 11 39 31 AM rvess BL99 01 7/10/09 JLL BLDG FINAL TIME 01 00 July 8 2009 4 28 59 PM 1pangrle O LANCE 360 782 4829 BLDG FINAL ATM (SOUND COMMUNITY BANK) AFTERNOON COMMENTS AND NOTES DAT 7 7 05 0 .r b� 257 O NER/CONTRACTOR PA-LL 6_17 AN„LE1.ES (O"-\ ADDRESS PERMIT M i/o f•) 141.1»-► APPROVED NOT APPROVED DITCH ROUGH IN /COVER SERVICE FINAL a CORRECTIONS NEEDED: ELECTRICAL INSPECTION WIRING REPORT 417 -4735 r )4 fiN STALUA`r /e A/ INSPECTO NOTIFY INSPECTOR WHEN CORRECTIONS ARE COMPLETED WITHIN 15 DAYS DO NOT REMOVE ELECTRICAL INSPECTION WIRING REPORT 417 -4735 DA PERMIT -7/7/0, 69-6222 INSPECTO OVJNER/CONTMACTOR ADDRESS 1W !.1 a g7 APPROVED NOT APPROVED DITCH ROUGH IN /COVER SERVICE FINAL CORRECTIONS NEEDED: i t S 1.4 1 'rP LLAYIO II _ZGPT j ni 1.21,-% 4 s..! S 1vT EloON1 1' J— l 10 Zn! 7Fc2 -ll4 r ALL xtcrz LTS 1,)6a K NOTIFY INSPECTOR WHEN CORRECTIONS ARE COMPLETED WITHIN 15 DAYS DO NOT REMOVE TUBE ART GLWIIJP June 16, 2009 Linda Pangrle City of Port Angeles 321 East Fifth Street P 0 Box 1 150 Port Angeles, WA 98362 0217 Re Sound Community Bank pmt #09 00000426 Enclosed please find the signed permit copy for your files. Please feel free to call me at (206) 223 -1122, if you should have any questions. Sincerely TUBE ART DISPLAYS, INC Shawn Bowen Permit Acquisition SEATTLE OFFICE I 1705 4th Ave South Seattle WA 98134 -1514 1 206.223 1122 I 800.562.2854 I Fax 206.223 1123 I tuheartgroup corn CITY OF PORT ANGELES DEPARTMENT OF COMMUNITY ECONOMIC DEVELOPMENT BUILDING DIVISION 321 EAST 5TH STREET PORT ANGELES WA 98362 Application Number 09 00000426 Date 6/02/09 Application pin number 197824 Property Address 110 N ALDER ST ASSESSOR PARCEL NUMBER 06 30 00 5 6 0125 0000 Tenant nbr name SOUND COMMUNITY BANK Application type description SIGNS Subdivision Name Property Use Property Zoning COMMERCIAL ARTERIAL Application valuation 9500 Application desc RETRO FIT TWO SIGNS WITH NEW SIGN CABINETS Owner Contractor GALE P QUINN TUBE ART DISPLAYS INC 560 SE MIDWAY BLVD 1705 4TH AVE S OAK HARBOR WA 982775018 SEATTLE WA 98134 (206) 223 1122 Permit SIGN Additional desc 2 FREESTANDING SIGNS Permit pin number 145680 Permit Fee 230 00 Plan Check Fee 00 Issue Date 6/02/09 Valuation 9500 Expiration Date 11/29/09 Qty Unit Charge Per 2 00 115 0000 PER S F/S OR PROJ SIGN 25 SF Special Notes and Comments May 27 2009 9 41 04 AM sroberds The sign permit will result in the removal of existing sign cabinets and placement of two new cabinets on two separate free standing sign poles in the CA zone No land use issues are anticipated Fee summary Charged Paid Credited Due Permit Fee Total 230 00 230 00 00 00 Plan Check Total 00 00 00 00 Grand Total 230 00 230 00 00 00 T:Forms/Building Division/Building Permit Extension 230 00 Separate Permits are required for electrical work, SEPA, Shoreline, ESA, utilities, private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned fora period of 180 days after the work has commenced, or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. is oq 91,64 a -7\I Date Print Name Signature Eutho Agent Signature of Owner (if owner is builder) Inspection Type FOUNDATION Footings Stemwall Foundation Drainage Downspouts Piers Post Holes (Pole Bldgs PLUMBING Under Floor Slab Rough -In Water Line (Meter to Bldg) Gas Line Back Flow Water AIR SEAL. Walls Ceiling FRAMING Joists Girders Under Floor Shear Wall Hold Downs Walls Roof Ceiling Drywall (Interior Braced Panel Only) T -Bar INSULATION Slab Wall Floor Ceiling MECHANICAL. Heat Pump Furnace FAU Ducts Rough -In Gas Line Wood Stove Pellet Chimney Commercial Hood Ducts MANUFACTURED HOMES Footing Slab Blocking Hold Downs Skirting T Forms /Building Division /Building Permit BUILDING PERMIT INSPECTION RECORD PLEASE PROVIDE A MINIMUM 24 -HOUR NOTICE FOR INSPECTIONS Building Inspections 417 4815 Electrical Inspections 417 4735 Public Works Utilities 417 4831 Backflow Prevention Inspections 417 4886 IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED POST PERMIT IN CONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE. Date Electrical 417 -4735 Construction R.W PW Engineering 417 -4831 Fire 417 -4653 Planning 417 -4750 Building 417 -4815 Accepted By Comments PLANNING DEPT Separate Permit #s SEPA. Parking Lighting I ESA. Landscaping I SHORELINE. FINAL Date Accepted by FINAL Date Accepted by FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/ USE Inspection Type Date Accepted By 1-10- 6q ExISTINCt 511.w3 ratT fc& 15 4 :50u OMMUNIT BANK( re Front View 1 Scale: 1/4' 1' 0" L 5 G TubeArt t Tube Art Displays, Inc. 1705 4th Avenue S Seattle, WA Tel 206 223 1122 800 562 2854 Fax 206 223 1123 Manufacture and install two (2) new I!6N C-PziN utilizing existing poles. Cabinet to be SignComp aluminum extrusion painted Black. Faces to he White flexible material. Orca graphic to be digital print. "SOUND" and "DRIVE THRU ATM' background to match 3M Holly Green #230- 76 vinyl film. ATM copy is reversed out. "COMMUNITY BANK" copy is 3M 230-22 Black vinyl Internal illumination to be 800ma high output fluorescent lamps. OWatchfire Time and Temperature Amber LED signs mounted back to back on pole cover. 011 1/2° deep x 4 wide cedar pole covers by others. f<e 4k-eki IrE0 it -.Exts11134.1 14 SQl■ifi+E •t2.6 rtoTit461 Current Conditions Current Conditions !EXPIRES 4/10/2010 4 1 Sound Community Bank Port Angeles, WA Sign Support and Foundation Structural Calculations June 1, 2009 Prepared for TubeArt 1705 4th Ave S Seattle WA 98134 (206) 223 -1122 EXPIRES 4/10!2010 Prepared By Samir Chudgar, P.E., S.E Chudgar Engineering Company 16230 NE 25th St Bellevue, WA 98008 (425) 881 -8979 CHUDGAR ENGINEERING COMPANY Job No 622 Task No 51 Date Project Sound Community Bank By Subject Sign and Support Foundation Sian and Su000rt Desian Wind Load Design is according to IBC 2006 and as per ASCE 7 -05 Section 6 5 14 Design Wind Load F qh G *Cf Af Sign Dimensions Height of support post 19.92 ft Height of solid sign frame 10 08 ft Width of solid sign frame 15 00 ft Height from ground to centroid of sign 24 96 ft h 30 ft qh Exposure C Basic wind speed V 100 mph s 1008 ft h 30 ft B 15 00 ft Clearance Ratio s/h 0.34 Aspect Ratio B/s 1 49 Force Coefficient Case A Force normal to sign Cf 1.8 ASCE 7 -05 Fig 6 -20 Gust Factor G 0 85 Sec 6 5 8 Velocity Pressure qz 000256 *Kz *Kzt Kd *VA2 I Wind Directionality Factor Kd 0 85 Table 6 -4 for solid sign Velocity Pressure Coefficient Kz 0 98 Table 6 -3 Height h 30 ft Exposure C Topographic Factor Kzt 1 Sec 6.5 7.2 Basic Wind Speed V 100 mph Fig 6 -1 Port Angeles Page 1 of 3 Sec 6.5 10 6/1/09 SC A CHUDGAR ENGINEERING COMPANY Job No. 622 Task No 51 Date 6/1/09 Project Sound Community Bank By SC Subject Sign and Support Foundation Occupancy Category Importance Factor I qh Use Design Wind Pressure Sian Dimensions pw Distance from ground line to bottom of sign 19.92 ft Lateral Pressure at top 0 psf Lateral Pressure at bottom 1350 psf Total lateral resistance 30375 lb Centroid of lateral resistance from ground line 6 00 ft Total Resisting Moment 182250 ft Page 2 of 3 II Standard 1 0 Table 6 -1 21.32 psf 25 00 psf Number Shape B H Bottom of Area of Lateral Overturning to centroid sign Load Moment at Base ft ft ft sf lb lb -ft 1 rectangle 15 00 10 08 5 04 151.20 3780 94349 Foundation Desian Per IBC Table 1804.2 Soil Profile assumed sand silty sand clayey sand Allowable Foundation Pressure 1500 psf Lateral Bearing Pressure 150 psf /ft below grade Coefficient of Friction 0.25 Foundation Dimensions Number of Footings 1 Length or Diameter 5 ft Use Width 5 ft Use Depth below grade 9 ft Use Foundation concrete above grade 0 00 ft Factor of Safety against Sliding 8 04 .1 5 OK Adequate CHUDGAR ENGINEERING COMPANY Job No 622 Task No 51 Date Project Sound Community Bank By Subject Sign and Support Foundation Factor of Safety against Overturning 1 93 1.5 OK Adequate Weight Sign Weight 500 lb considered Sign Framing Post 14x14x5/15 1142.6 lb Sign total weight 1642.611 lb Foundation base area 25 0 sf Soil Pressure 65 7 psf Allowable soil pressure 1500 psf OK Load Combination Allowable Stresses Method Dead Load Wind Load Evaluate Post as TS14x14 Number of posts 1 Maximum moment at base of each post 94349 lb -ft Design Moment for post 103784 lb -ft w/ 10% increase Post Tube dimensions Length 14 in Use Width 14 in Use Wall thickness 0.3125 in Use Fy 35 ksi I Inertia 522.0 in4 Sx, Section Modulus 74 6 in3 fb Bending Stress 16 69 ksi Fb OK Fb Allowable Bending Stress 0 60Fy Adequate 21 0 ksi D +W IBC 1605 3 Eqn 16 -12 6/1/09 SC PREPARED 5/28/09 8 43 00 INSPECTION TICKET PAGE 4 CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 5/28/09 ADDRESS 110 N ALDER ST SUBDIV TENANT NBR SOUND COMMUNITY BANK CONTRACTOR GOLDEN HOME SERVICES INC PHONE (360) 782 4829 OWNER GALE P QUINN PHONE (360) 675 5859 PARCEL 06 30 00 5 6 0125 0000 APPL NUMBER 09 00000139 COMM NEW CONST PERMIT BPC 00 BUILDING PERMIT COMMERCIAL REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS BL3 01 5/18/09 JLL BLDG FRAMING TIME 01 00 5/18/09 AP May 15 2009 8 20 34 AM 1pangrle LANCE 360 782 4829 FRAMING AFTERNOON May 18 2009 4 26 34 PM jlierly BLI 01 5/28/09 J BLDG INSULATION May 28 2009 8 22 27 AM 1pangrle LANCE 360 782 4829 INSULATION HE REQUESTED A MORNING INSPECTION COMMENTS AND NOTES PREPARED 5/18/09 8 55 27 INSPECTION TICKET PAGE 1 CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 5/18/09 ADDRESS 110 N ALDER ST SUBDIV TENANT NBR SOUND COMMUNITY BANK CONTRACTOR GOLDEN HOME SERVICES INC PHONE (360) 782 4829 OWNER GALE P QUINN PHONE (360) 675 5859 PARCEL 06 30 00 5 6 0125 0000 APPL NUMBER 09 00000139 COMM NEW CONST PERMIT BPC 00 BUILDING PERMIT COMMERCIAL REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS BL3 01 5/18/09 JL BLDG FRAMING TIME 01 00 May 15 2009 8 20 34 AM 1pangrle LANCE 360 782 4829 FRAMING AFTERNOON COMMENTS AND NOTES Application Number Application pin number Property Address ASSESSOR PARCEL NUMBER Application type description Subdivision Name Property Use Property Zoning Application valuation Application desc Sign Permit Owner Sound Community Bank 2005 5th Ave SEATTLE Permit Additional desc Permit pin number Permit Fee Issue Date Expiration Date Qty Unit Charge Per 1 00 69 0000 ECH EL COMM SIGN Fee summary Permit Fee Total Plan Check Total Grand Total INSPECTION TYPE DITCH SERVICE ROUGH IN FINAL COMMENTS WA 98121 ELECTRICAL PERMIT CITY OF PORT ANGELES 360 417 -4735 09 00000423 106997 110 N ALDER ST 06 30 00 5 6 0125 0000 ELECTRICAL ONLY 145656 69 00 5/14/09 11/10/09 COMMERCIAL ARTERIAL 0 Contractor ELECTRICAL ALTER COMMERCIAL TUBE ART DISPLAYS INC 1705 4TH AVE S SEATTLE SEATTLE (206) 223 1122 Plan Check Fee Valuation Charged Paid Credited 69 00 69 00 00 00 00 00 69 00 69 00 00 DATE RESULTS )-7(01 4/7/69 Date 5/14/09 Due WA 98134 00 0 Extension 69 00 00 00 00 Signature of owner or Electrical Contractor X Date INSPECTOR. Aug -15 -00 08 28 Port Angeles PublBE IVED P 01 O�vOF���, MAY 1 2 2009 c�/ fUlt Ol'I'll. :IAL USI:aNIY ELECTRICAL PERMIT APPLICATION 't` `t°` Pcrnut Il: Unto Approved: The Electrical Permit Application must be filled ou QQ com9g!T31 Unte Iseued: Please type or print in ink, If you have any questions, please call (360) 417 -4735 Fax number (360) 417 -4711 r oDe, T/S ftA-t a Applicant and/or Agent Phone :2 i /Z3 1t22- Fax #2 6 ,2z� Property Owner ,:,2,1/43 0 0 C owwtJIvtT Cy r Phone Address 11 0 A ST City Pr, A0 5 S Zip: Contractor A1 T License #i rJ )0 xp. 6 "t Phone:2 23) 1 22 Address 1 4 114 AkS City: S; r1Ti 11,44 Zip c 7�( 341 r Credit Card Holder Name Billing Address: City Zip. Credit Card Number Exp. Date VISA MC Permit Fee: PROJECT ADDRESS. J 10 1V 1 A' l' t 4 ZONING LEGAL DESCRIPTION: Lot: Block: Subdivision. CLALLAM COUNTY PARCEL NUMBER. TYPE OF WORK. Residential Multi family Commercial a Mobile Home Electrical Permit fees are based on WAC 296 -46 -910 BRIEF DESCRIPTION OF THE PROJECT 12 F e L Si b /J t GAT (1e Comments PUG -15 -2000 09 07 ElairkallicatisalAthilticat Service Information Baseboard KW Riser Voltage: Furnace KW a Overhead Service Phase: a 1 a 3 Heat Pump KW Temp Service Service Size: Fan Wall KW 0 Underground Service Feeder Size: I hereby certtfi' that I have read anih amined this application and know the same to be true and correct, and I am authorized to apply for this permit. I understand it is not Me City's legal responsibility to determine what permits are required• a remains Me applicant's responsibility to determine ghat permits are required and to obtain such. PW 1102_2:t frevtt.t101 Credit Card Holder's Signature: 97% P 01 Look Up a Contractor, Electrician, Plumber or Elevator Professional License Detail Page L of 2 Return to List Start a New Search LZ Printer friendly Electrical Contractor A business licensed by LEtI to contract electrical work within the scope of its specialty Electrical Contractors must maintain a surety bond or assignment of savings account They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full time supervisory employee Business and Licensing Information Verify Workers Name Phone No Address Suite /Apt. City State Zip County Business Type Parent Company Comp Premium Status TUBE ART DISPLAYS INC (206) 223 1122 1705 4TH AVE S SEATTLE WA 98134 KING Corporation 1MASTER ELECTRICIAN INFORMATION License HARGEJP974OS Name HARGETT, JEFFREY P Status ACTIVE B Business Owner Information Name KTC SERVICE CORPORATION, DUPAR, SKIP HARGETT, JEFFREY MONTERO, WILLIAM SCHMOLL, DON DUPAR, FRANK A III MAAS, WALTER M III COLLINS, JAMES Information in Spanish AGENT AGENT SECRETARY Hide All Role AGENT PRESIDENT SECRETARY VICE PRESIDENT Topic Index 1 Contact Info I I Search Home Safety Claims Insurance Workplace Rights Trades Licensing Find a Law (RCW) or Rule (WAC) Get a form or publication I CiO H elp UBI No. Status License No License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 Check for Dept. of Revenue Account J 178073073 ACTIVE TUBEADI110NH J ELECTRICAL CONTRACTOR 8/8/1989 8/8/2009 J SIGN J UNUSED Effective Date 09/19/2003 09/16/2003 09/16/2003 01/01/1980 01/01/1980 01/01/1980 01/01/1980 01/01/1980 Expiration Date 09/16/2003 09/16/2003 09/16/2003 09/16/2003 https. /fortress wa.gov /lm /bbip /Detail.aspx 5/12/2009 Look Up a Contractor, Electrician, Plumber or Elevator Professional License Detail Page 2 of 2 <et SI B Bond Information i Bond Bond Bond Company Account Name Number TRAVELERS 3 CAS Et SURETY CO B Infraction Citation Information j) Infration /Citation Date RCW Code EKENJ00252 2/17/2009 EKENJ00253 2/17/2009 EROBA00016 9/15/2005 EROBA00013 9/15/2005 EJUBD00245 10/2/2008 EREYT00207 Acuss Ve ishlrlglon' 55 "Itc Effective Date 103378976 08/08/2000 Until Cancelled 19 28 271 RCW 19 28 101 RCW 19 28 161 RCW 19 28 271 RCW 19 28 101 RCW 10/18/2005 28 101 RCW Expiration Cancel Impaired Bond Received Date Date Date Amount Date Type ELECTRICAL CITATION ELECTRICAL CITATION ELECTRICAL CITATION ELECTRICAL CITATION ELECTRICAL CITATION ELECTRICAL CITATION $4,000 00 Status Violation Amount Satisfied $250 00 Satisfied $1,000 00 Satisfied $250 00 Satisfied $250 00 Satisfied $250 00 Satisfied $250 00 About L &I I Find a job at LEN I Site Feedback I Toll -free Numbers CO Washington State Dept. of Labor nd Industries. Use of thi ite is object to the laws of the state of Washington. Access Agreente ll I P_rwrcy_dnd seep !ty_Ltaiefnent I Intended_use /exteroat_co!Sent policy I S_3.ff onty_li tk https. /fortress wa.gov/lni/bbip/Detail.aspx 5/12/2009 owvIer cer c uit wdbsii-e Gale P Qva nh 560 SE (Yll-j Oak 1- PaurbOr 9 -5o BUILDING PERMIT PREAPPLICATiON X Owner c6csrJ> Ce r-r) &e The Building Permit Preapplication must be filled out completely Please type or print in ink. If you have any questions, please call 417 -4815 s A 5hrtu« Tube wet corn Applicant and/or Agent 1 v 1�� -75 �t.-1� Phone Address. 110 (J Ac c. D 5T. Architect/Engineer F> A Contractor 7:-)t3 Ili de)s 4r1+ ,o S Address TYPE OF WORK. New Conf Addition Move o Remodel Demolition Repair Sign BRIEF DESCRIPTION OF THE PROJECT _Sri e-A-it-U r LEGAL DESCRIPTION Lot.Iesk:�_ o Residential o Multi- family Commercial City PROJECT ADDRESS I I o N A 1_t �T sohs stove o Garage Deck 1FTi2o Fir COMMERCIAL/RESIDENTIAL. Occupancy Group No. of Stories: Lot Size: Lot Coverage: Existing Lot Coverage. /sq ft. +Proposed Lot Coverage: PLANNING USE ONLY Permits Required. Max. Height. Setbacks: Site Plan and Use Approved b} ESA/Wetland(s) Yes No SEPA Checklist required? P\V 1102_131rev.2/961 Phone License #':7 3 P D E3110 xp ID City Subdivision. SIZE/VALUATION SF /SF SF @a /SF SF /SF TOTAL VALUATION 4Sea r' S t- C-z S f ta.rJ t.J Occupant Load. Notes: Zoning: Date: Yes 0 No Other Phone. ZONING Construction Type: `GGS 1 122 Zip /sq. ft. TOTAL LOT COVERAGE. /sq.ft APPROVALS. PLAN BLDG DPW FIRE OTHER FOR OFFICIAL USE 0 Y Date Rec. tS Q Permit ti• Pre-Ap Comp Date Approved: Phone. Z06Z23 I10-- Zip 1 134 PREAPPLICATION SUBMITTAL. Your application and site plan must be filled out completely to be accepted for review. The Building Division can provide you with more detailed information on the application and plan submittal requirements. BUILDING PERMIT APPLICATION SUBMITTAL. Your completed application, site plan (for additions) and building construction plans are to be submitted to the Building Division. VALUATION OF CONSTRUCTION. In all cases, a valuation amount must be entered by the applicant. This figure will be reviewed and may be revised by the Building Div to comply with current fee schedules. Contact the Permit Coordinator at 417 -4815 for assistance. PLAN CHECK FEE. Your plan check fee is due at the time the building permit application and construction plans are submitted. All other permit fees are due at the time of permit issuance. EXPIRATION OF PLAN REVIEW If no permit is issued within 180 days of the date of application, this application will expire by limitations. The Building Official can extend the time for action by the applicant up to 180 days, on written request by the applicant (see Section 304(d) of the Uniform Building Code, current edition) No application can be extended more than once. I hereby certijr that have read and examined this application and blow the same to be true and correct, and 1 am authorized to apply for this permit. I understand it is not the City's legal responsibility to determine what permits are required, it remains the applicant's responsibility to determine what permits are required and to obtain such r Applicant. N Date: 9 S3ION /NV 1451 1f?i —sr Sali4 1 1 Iv 97 11 )19 0.4.sc: 1-7--f solo dorsrma 2rrrpunEusu.uo3 o #nWJed 1' 5 3/4' '11 p. I �21� r F-VA SCLir3 15' -0 I r 48" Time4Temu I 1 l 30 7 1 f 1- I I I' 1 1 1 I V M j 0 1 CI N o ,r ou t-C IC OMMUNIT ra 3 E C!TY PORT Afki(iEP.ES C ruction Plans The Issuance of this permit based upon these plans, spaci i- somas and other da ta qfiaMot prevent the building official sr` n req 1 tf gaItt1L "cerrecffion of errors in Sala pia specifications and other data, or from preventing building operations being carried on thereunder when in violation of all codes and ordinances of 's iprisdiction. (SECTION 303(c) nit rm Building Code.) Approval Date By fu r o r OxtS-nNLR Sttz tar;tx3t -Tt —:-f kt DRNE THRL 1 ATM A Cabinet to be SignCmnp aluminum extrusion painted Black. 3 Faces to be White flexible material. Orca graphic to be digital print. 1 "SOUND" and "DRIVE THRU ATM" background to match 3M Holly Green #230- 76 vinyl film. ATM copy is reversed out. COMMUNITY BANK° copy is 3M 230 -22 Black vinyl Internal illumination to be 800ma high output fluorescent lamps. Watchfire Time and Temperature Amber LED signs mounted back to back on pole cover. 11 1 /T' deep x 4' -0" wide cedar pole covers by others. 1, 1 S1EIN —7 431 f Kew tlfD I'rc `la rr t x1ST114, 14x4 Sc Te Manufacture and install two (2) new'freestanding signs utilizing existing poles. New Sign SOUND BANK CO Current Conditions Architectural Electrical Displays 1705 411 Ay S. and Flo 5 II WA 98 34 TEL 206 23 1122 U A I BO0 552 2854 FAX 06 3 11 3 This ononel riwu* protected ride Fede at Copyright La Make eproducti of tin design newt 'bout vertu ss.o it eArL 2919 OUS10r1 e IUMBEn 112132 05101E HOYDEN SC8132 Port Angeles r2 FILE HALIE Temple Voorhees A.ESPEASON Karen Fischer DRAWN at CDECNEO Di January at, 2008 DATE February 17.2009 March 23 2009rCJ1 NEE 5 Oh 4 A I I AOpr ed I I Appr ed 7th change pled Iv ter SOUND COMMUNITY BANK Port Angela WA cows pd° do not ac moiet dep�.c specdied colors 1 o 1 PROJECT INFO/TEAM 190,, 09.,:19.9E910917FD.A1 _tea ME s, 2 9999 MO, ec 0/9514 REFT OMB( 01199 .ter l cc 159 5 Sound Community Bank Port Angeles Branch n North AMa Armes 96 62 SITE PLAN/ ROJECT INFO. PERMIT DRAWINGS CIO Al 1 r PREPARED 5/07/09 8 17 30 INSPECTION TICKET PAGE 5 CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 5/07/09 ADDRESS 110 N ALDER ST SUBDIV TENANT NBR SOUND COMMUNITY BANK CONTRACTOR GOLDEN HOME SERVICES INC PHONE (360) 782 4829 OWNER GALE P QUINN PHONE PARCEL 06 30 00 5 6 0125 0000 APPL NUMBER 08 00001492 COMM NEW CONST REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS May 6 2009 4 54 09 PM 1pangrle LANCE 360 782 4829 REBAR HE WANTS TO BE YOUR LAST INSPECTION OF THE DAY COMMENTS AND NOTES PREPARED 5/05/09 8 25 24 INSPECTION TICKET PAGE 2 CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 5/05/09 ADDRESS 110 N ALDER ST SUBDIV TENANT NBR SOUND COMMUNITY BANK CONTRACTOR GOLDEN HOME SERVICES INC PHONE (360) 782 4829 OWNER GALE P QUINN PHONE PARCEL 06 30 00 5 6 0125 0000 APPL NUMBER 08 00001492 COMM NEW CONST PERMIT BPC 00 BUILDING PERMIT COMMERCIAL REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS BL1 01 1/13/09 JLL BLDG FOUNDATION FOOTING TIME 01 00 1/13/09 AP January 13 2009 8 20 38 AM 1pangrle LANCE 782 4829 FOOTINGS AFTERNOON January 13 2009 4 55 04 PM jlierly BLIS 01 1/15/09 JLL BLDG INSULATION /SLAB 1/15/09 AP February 18 2009 10 40 51 AM 1pangrle SLAB INSULATION February 18 2009 10 41 19 AM 1pangrle BL1 02 1/15/09 JLL BLDG FOUNDATION FOOTING TIME 01 00 1/15/09 AP January 14 2009 5 02 35 PM 1pangrle LANCE 782 4829 FOOTING AFTERNOON February 18 2009 10 41 33 AM 1pangrle BL9 01 2/19/09 JLL BLDG SHEARWALL TIME 01 00 2/26/09 AP February 19 2009 8 24 48 AM 1pangrle LANCE 360 782 4829 SHEARWALL AFTERNOON February 26 2009 3 52 13 PM jlierly DSD 01 4/07/09 JLL BLDG DOWN SPOUT DRAINS TIME 01 00 4/07/09 AP April 6 2009 4 29 24 PM 1pangrle LANCE 360 782 4829 'ROOF DRAIN April 7 2009 1 06 45 PM jlierly BL3 01 4/16/09 JLL BLDG FRAMING 4/17/09 AP April 16 2009 8 45 38 AM 1pangrle LANCE 360 782 4829 FRAMING April 17 2009 4 16 00 PM jlierly BAIR 01 4/21/09 JLL BLDG AIR SEAL 4/21/09 AP April 21 2009 8 17 19 AM 1pangrle LANCE 360 782 4829 AIRSEAL HE REQUESTED A MORNING INSPECTION IF POSSIBLE April 21 2009 4 07 11 PM jlierly BLI 01 4/23/09 JLL BLDG NSULATION 4/23/09 AP April 23 2009 9 31 15 AM 1pangrle LANCE 360 782 4829 INSULATION April 23 2009 4 04 18 PM jlierly BLEW 01 5/05/09 CAL BLDG FOUND FTG /STEM WALL TIME 09 00 May 4 2009 4 21 11 PM 1pangrle LANCE 360 782 4829 FOUNDATION /STEMWALL FORMS /REBAR MORNING COMMENTS AND NOTES PREPARED 4/23/09 9 46 32 INSPECTION TICKET PAGE 1 CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 4/23/09 ADDRESS 110 N ALDER ST SUBDIV TENANT NBR SOUND COMMUNITY BANK CONTRACTOR GOLDEN HOME SERVICES INC PHONE (360) 782 4829 OWNER GALE P QUINN PHONE PARCEL 06 30 00 5 6 0125 0000 APPL NUMBER 08 00001492 COMM NEW CONST PERMIT BPC 00 BUILDING PERMIT COMMERCIAL REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS BL1 01 1/13/09 JLL BLDG FOUNDATION FOOTING TIME 01 00 1/13/09 AP January 13 2009 8 20 38 AM 1pangrle LANCE 782 4829 FOOTINGS AFTERNOON January 13 2009 4 55 04 PM jlierly BLIS 01 1/15/09 JLL BLDG INSULATION /SLAB 1/15/09 AP February 18 2009 10 40 51 AM 1pangrle SLAB INSULATION February 18 2009 10 41 19 AM 1pangrle BL1 02 1/15/09 JLL BLDG FOUNDATION FOOTING TIME 01 00 1/15/09 AP January 14 2009 5 02 35 PM 1pangrle LANCE 782 4829 FOOTING AFTERNOON February 18 2009 10 41 33 AM 1pangrle BL9 01 2/19/09 JLL BLDG SHEARWALL TIME 01 00 2/26/09 AP February 19 2009 8 24 48 AM 1pangrle LANCE 360 782 4829 SHEARWALL AFTERNOON February 26 2009 3 52 13 PM jlierly DSD 01 4/07/09 JLL BLDG DOWN SPOUT DRAINS TIME 01 00 4/07/09 AP April 6 2009 4 29 24 PM 1pangrle LANCE 360 782 4829 ROOF DRAIN April 7 2009 1 06 45 PM jlierly BL3 01 4/16/09 JLL BLDG FRAMING 4/17/09 AP April 16 2009 8 45 38 AM 1pangrle LANCE 360 782 4829 FRAMING April 17 2009 4 16 00 PM jlierly BAIR 01 4/21/09 JLL BLDG AIR SEAL 4/21/09 AP April 21 2009 8 17 19 AM 1pangrle LANCE 360 782 4829 AIRSEAL HE REQUESTED A MORNING INSPECTION IF POSSIBLE April 21 2009 4 07 11 PM jlierly BLI 01 4/23/09 BLDG INSULATION April 23 2009 9 31 15 AM 1pangrle LANCE 360 782 4829 INSULATION COMMENTS AND NOTES PREPARED 4/21/09 8 24 13 INSPECTION TICKET PAGE 1 CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 4/21/09 ADDRESS 110 N ALDER ST SUBDIV TENANT NBR SOUND COMMUNITY BANK CONTRACTOR GOLDEN HOME SERVICES INC PHONE (360) 782 4829 OWNER GALE P QUINN PHONE PARCEL 06 30 00 5 6 0125 0000 APPL NUMBER 08 00001492 COMM NEW CONST PERMIT BPC 00 BUILDING PERMIT COMMERCIAL REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS BL1 01 1/13/09 JLL BLDG FOUNDATION FOOTING TIME 01 00 1/13/09 AP January 13 2009 8 20 38 AM 1pangrle LANCE 782 4829 FOOTINGS AFTERNOON January 13 2009 4 55 04 PM jlierly BLIS 01 1/15/09 JLL BLDG INSULATION /SLAB 1/15/09 AP February 18 2009 10 40 51 AM 1pangrle SLAB INSULATION February 18 2009 10 41 19 AM 1pangrle BL1 02 1/15/09 JLL BLDG FOUNDATION FOOTING TIME 01 00 1/15/09 AP January 14 2009 5 02 35 PM 1pangrle LANCE 782 4829 FOOTING AFTERNOON February 18 2009 10 41 33 AM 1pangrle BL9 01 2/19/09 JLL BLDG SHEARWALL TIME 01 00 2/26/09 AP February 19 2009 8 24 48 AM 1pangrle LANCE 360 782 4829 SHEARWALL AFTERNOON February 26 2009 3 52 13 PM jlierly DSD 01 4/07/09 JLL BLDG DOWN SPOUT DRAINS TIME 01 00 4/07/09 AP April 6 2009 4 29 24 PM 1pangrle LANCE 360 782 4829 ROOF DRAIN April 7 2009 1 06 45 PM jlierly BL3 01 4/16/09 JLL BLDG FRAMING 4/17/09 AP April 16 2009 8 45 38 AM 1pangrle LANCE 360 782 4829 FRAMING April 17 2009 4 16 00 PM jlierly BAIR 01 4/21/09 BLDG All SEAL Apri l 21 20000 9 8 17 19 AM 1pangrle LANCE 360 782 4829 AIRSEAL HE REQUESTED A MORNING INSPECTION IF POSSIBLE COMMENTS AND NOTES PREPARED 4/16/09 8 48 48 INSPECTION TICKET PAGE 1 CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 4/16/09 ADDRESS 110 N ALDER ST SUBDIV TENANT NBR SOUND COMMUNITY BANK CONTRACTOR GOLDEN HOME SERVICES INC PHONE (360) 782 4829 OWNER GALE P QUINN PHONE PARCEL 06 30 00 5 6 0125 0000 APPL NUMBER 08 00001492 COMM NEW CONST PERMIT BPC 00 BUILDING PERMIT COMMERCIAL REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS BL1 01 1/13/09 JLL BLDG FOUNDATION FOOTING TIME 01 00 1/13/09 AP January 13 2009 8 20 38 AM 1pangrle LANCE 782 4829 FOOTINGS AFTERNOON January 13 2009 4 55 04 PM jlierly BLIS 01 1/15/09 JLL BLDG INSULATION /SLAB 1 /15/09 AP February 18 2009 10 40 51 AM 1pangrle SLAB INSULATION February 18 2009 10 41 19 AM 1pangrle BL1 02 1/15/09 JLL BLDG FOUNDATION FOOTING TIME 01 00 1/15/09 AP January 14 2009 5 02 35 PM 1pangrle LANCE 782 4829 FOOTING AFTERNOON February 18 2009 10 41 33 AM 1pangrle BL9 01 2/19/D9 JLL BLDG SHEARWALL TIME 01 00 2/26/09 AP February 19 2009 8 24 48 AM 1pangrle LANCE 360 782 4829 SHEARWALL AFTERNOON February 26 2009 3 52 13 PM jlierly DSD 01 4/07/09 JLL BLDG DOWN SPOUT DRAINS TIME 01 00 4/07/09 AP April 6 2009 4 29 24 PM 1pangrle LANCE 360 782 4829 'ROOF DRAIN April 7 2009 1 06 45 PM jlierly BL3 01 4/16/09 J BLDG FRAMING LL April 16 2009 8 45 38 AM 1pangrle LANCE 360 782 4829 FRAMING PERMIT ME 00 MECHANICAL PERMIT REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS ME1 01 4/16/09 MECHANICAL ROUGH IN LL April 16 2009 8 46 15 AM 1pangrle LANCE 360 782 4829 MECHANICAL ROUGH IN COMMENTS AND NOTES PREPARED 4/07/09 8 43 53 INSPECTION TICKET PAGE 3 CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 4/07/09 ADDRESS 110 N ALDER ST SUBDIV TENANT NBR SOUND COMMUNITY BANK CONTRACTOR GOLDEN HOME SERVICES INC PHONE (360) 782 4829 OWNER GALE P QUINN PHONE PARCEL 06 30 00 5 6 0125 0000 APPL NUMBER 08 00001492 COMM NEW CONST PERMIT BPC 00 BUILDING PERMIT COMMERCIAL REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS BL1 01 1/13/09 JLL 1/13/09 AP BLIS 01 1/15/09 JLL 1/15/09 AP BL1 02 1/15/09 JLL 1/15/09 AP BL9 01 2/19/09 JLL 2/26/09 AP DSD 01 4/07/09 BLDG FOUNDATION FOOTING TIME 01 00 January 13 2009 8 20 38 AM 1pangrle LANCE 782 4829 FOOTINGS AFTERNOON January 13 2009 4 55 04 PM jlierly BLDG INSULATION /SLAB February 18 2009 10 40 51 AM 1pangrle SLAB INSULATION February 18 2009 10 41 19 AM 1pangrle BLDG FOUNDATION FOOTING TIME 01 00 January 14 2009 5 02 35 PM 1pangrle LANCE 782 4829 FOOTING AFTERNOON February 18 2009 10 41 33 AM 1pangrle BLDG SHEARWALL TIME 01 00 February 19 2009 8 24 48 AM 1pangrle LANCE 360 782 4829 SHEARWALL AFTERNOON February 26 2009 3 52 13 PM jlierly BLDG DOWN SPOUT DRAINS TIME 01 00 April 6 2009 4 29 24 PM 1pangrle LANCE 360 782 4829 ROOF DRAIN' COMMENTS AND NOTES Application Number Application pin number Property Address ASSESSOR PARCEL NUMBER Application type description Subdivision Name Property Use Property Zoning Application valuation Application desc t stat Owner Sound Community Bank P 0 Box 34155 SEATTLE Permit Additional desc Permit pin number Permit Fee Issue Date Expiration Date Qty Unit Charge Per 2 00 43 7500 ECH EL LVT THERMOSTAT Fee summary INSPECTION TYPE DITCH SERVICE ROUGH IN FINAL COMMENTS WA 98124 ELECTRICAL ALTER COMMERCIAL 143685 87 50 3/31/09 9/27/09 ELECTRICAL PERMIT CITY OF PORT ANGELES 360 -417 -4735 09 00000281 030040 110 N ALDER ST 06 30 00 5 6 0125 0000 ELECTRICAL ONLY COMMERCIAL ARTERIAL 0 Contractor AIR FLO HEATING CO INC 221 W CEDAR SEQUIM (360) 683 3901 Plan Check Fee Valuation Charged Paid Credited Permit Fee Total 87 50 87 50 00 Plan Check Total 00 00 00 Grand Total 87 50 87 50 00 DATE RESULTS W /t5jo,i -77- Date 3/31/09 WA 98382 Due 00 0 Extension 87 50 00 00 00 Signature of owner or Electrical Contractor X Date INSPECTOR. 03/30/2009 MON 11 32 FAX 360 683 3971 ARE IVED City of Port Angeles Permit Application Building Division /Electrical Inspections 321 East Fifth Street P.O. Box 1150 Port Angeles Washington, 98362 Ph: (360) 417-4735 Fax: (360) 417.4711 Date: ?i -3D17 1 2 Single Family Dwelling Multi Family or Commercial' Commercial Addition I Alteration 1 Remodel I Repair' Plan Review May Be Required, Please C mplete E12 PI Revi Informatiog Sheet Job Address: I Q N 1 te, L�_ Building Square Footage: Description of above IgtIALA,Cwatar 1 Owner Igformation n Q Name: JO I) V1 d Of'1'l nil Oi l j tS Mailing Address: i 1 IJ ®r 4 1.1) City* P4 J'�vtgti,r� S State: ft /A- Zip: i?z (o Phon'e: Fax: License #1 Exp Unit Charge 93.75 $113.75 $160.00 $205.00 $291.25 2.00 57.50 2.00 72.50 86.25 $116.25 $131.25 75.00 69.00 75.00 50.00 50.00 93.75 80.00 86.25 27.50 57.50 86.25 43.75 9Y MAR 3 0 2009 LIGHT DEPT �v r lali n dvi Total (City Multiolied by Unit Chara Service/Feeder 200 Amp. Contractor Information Name: jr t.le F LO t/l(? Mailing Address: 7 I 1A) /2,21X City: n u Wit Phone:fp "2.6961 Fax: 40Q License l Exp. i t 42 F LE4-11- p Q -t c ServicelFeeder 201 -400 Amp. Service/Feeder 401 -600 Amp. Service/Feeder 601 -1000 Amp. Service/Feeder over 1000 Amp. Branch Circuit W/ Service Feeder Branch Circuit W/O Service Feeder Each Additional Branch Circuit Temp. Service/ Feeder 200 Amp. Temp. Service/Feeder 201 -400 Amp. Temp. Service/Feeder 401 -600 Amp. Temp. Service/Feeder 601 -1000 Amp. Portal to Portal Hourly Sign/Outline Lighting Signal Circuit/ Limited Energy Commercial Signal Circuit/ Limited Energy 1 2 Family Dwelling Signal Circuit/ Limited Energy Multi- Family Dwelling Manufactured Home Connection Renewable Electrical Energy 5KVA System or Less First 1300 Square Ft. Each Additional 500 Square Ft. or Portion of Each Outbuilding or Detached Garage Z Each Swimming Pool or Hot Tub $1 SO Thermostat Total Owner as defined by RCW.19.28.261; (1) Owner will occupy the structure for two years after this electrical permit is finalized. (2) Owner is required to hire an electrical contractor if above said property is for sale, rent or lease. After reading the above statement, I hereby certify that I am the owner of the above named property or a licensed electrical contractor. I am making the electrical installation or alteration in compliance with the electrical laws, N.E.C. RCW. Chapter 19.28, WAC. Chapter 296.468, The City of Port Angeles Municipal Code, and Utility Specifications. Signatu of owner, electrical contractor or electrical administrator Cash Check fa_ Date: R Credit Card 00 /00 0 b PREPARED 3/24/09 8 12 53 INSPECTION TICKET PAGE 5 CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 3/24/09 ADDRESS 110 N ALDER ST SUBDIV TENANT NBR SOUND COMMUNITY BANK CONTRACTOR GOLDEN HOME SERVICES INC PHONE (360) 782 4829 OWNER GALE P QUINN PHONE PARCEL 06 30 00 5 6 0125 0000 APPL NUMBER 08 00001492 COMM NEW CONST PERMIT PL 00 PLUMBING PERMIT REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS PL2 01 3/24/09 JLL PLUMBING ROUGH IN TIME 01 00 March 23 2009 2 53 02 PM 1pangrle DOUG 457 1690 ROUGH IN PLUMBING AFTERNOON COMMENTS AND NOTES Application Number Application pin number Property Address ASSESSOR PARCEL NUMBER Application type description Subdivision Name Property Use Property Zoning Application valuation Application desc Phone data Owner Sound Community Banks P 0 Box 34155 SEATTLE Permit Additional desc Permit pin number Permit Fee Issue Date Expiration Date Fee summary Permit Fee Total Plan Check Total Grand Total INSPECTION TYPE DITCH SERVICE ROUGH IN FINAL COMMENTS WA 98124 09 00000251 112630 110 N ALDER ST 06 30 00 5 6 0125 0000 ELECTRICAL ONLY COMMERCIAL ARTERIAL 0 Contractor ELECTRICAL NEW COMMERICAL 143214 75 00 3/19/09 9/15/09 ELECTRICAL PERMIT CITY OF PORT ANGELES 360 417 -4735 DATE Date 3/19/09 ANGELES COMMUNICATIONS INC 102 ROSS LN PORT ANGELES WA PORT ANGELES (360) 457 4375 Plan Check Fee Valuation Qty Unit Charge Per 1 00 75 0000 ECH EL -ADDNT LIMITED 1500 SQ FT Charged Paid Credited 75 00 75 00 00 00 00 00 75 00 75 00 00 7'Iq !o'/ r RESULTS WA 98362 00 0 Extension 75 00 Due 00 00 00 Signature of owner or Electrical Contractor X Date INSPECTOR. Job wired by )4 Electrical Contractor Owner Electrical contractor name License number (:tiNl'i/>I/kat,eAT►'1 I Porch is mailing address /0a Po City LL orf I74 L.k Telephone number FAX number )60 45 7- ¥375 &,0 oa Premises owner's name 1 �Qtatt� cdfi //n.e17f`✓ k Address of Inspection I 0 H Ai- Phone number to schedule inspection' AGO 67o -1976 Owner as defined by RCW l9.28.26).(1) Owner will occupy the structure for two years after this electrical permit is finalized. (2) Owner is required to hire an electrical contractor i( above said property is for sale, rent or lease. After reading the above statement. I hereby certify that I am the owner of the above named property or a licensed electrical contractor. I am making the electrical instal- lation or alteration in compliance with the electrical laws, N,E.C. RCW Chapter 19.2$, WAC, Chapter 296 -46B, The City of Port Angeles Municipal Code, and Utility Specifications. /Signature of owner electrical contractor or electrical administrator State ZIP cJA 9 836 3 Date Expires X Date. 3-/19.49 m ..1 Electrical Load Additions and or subtractions: NO LOAD CHANGES Baseboard KW Furnace KW Overhead Service Heat Pump Ton LAR Temp Service Fan -Wall KW Underground Service SAME DAY INSPECTION. CALL BEFORE 7.00 AM 360- 417 -4735 ROUGH -IN THERMOSTAT Inspection Date Date Approved By FINAL Date Approved BY RECEIVED MAR 1 9 2009 ELECTRICAL WORK PERMIT APPLICATION Our N. Date DITCH Area, Building or Equipment Inspected Ia Commercial O Residential O New Altered/Addition LIGHT DEPT /Installation description fits tail pl+orle f1datee„r.S Lim O Cash Check Credit Card Visa Mastercard Discover Card Expiration Date \f card Approved Ay Approved By J Date Dale SERVICE Action Taken C Inspection f e rvlce Information Voltage Phase O 1 O 3 Service Size: Feeder Size: Approved By FEEDER Electrical Inspector Approved By Application Number Application pin number Property Address ASSESSOR PARCEL NUMBER Application type description Subdivision Name Property Use Property Zoning Application valuation Application desc Alarm system Owner Sound Community Bank P 0 Box 34155 SEATTLE Permit Additional desc Permit pin number Permit Fee Issue Date Expiration Date Fee summary Permit Fee Total Plan Check Total Grand Total INSPECTION TYPE DITCH SERVICE ROUGH IN FINAL COMMENTS WA 98124 143172 75 00 3/19/09 9/15/09 ELECTRICAL PERMIT CITY OF PORT ANGELES 360 -417 -4735 09 00000247 454852 110 N ALDER ST 06 30 00 5 6 0125 0000 ELECTRICAL ONLY COMMERCIAL ARTERIAL 0 Contractor ELECTRICAL NEW COMMERICAL Date 3/19/09 ALLIED SAFE AND VAULT CO 3051 E VALLEY RD RENTON (425) 988 6500 Plan Check Fee Valuation Qty Unit Charge Per 1 00 75 0000 ECH EL ADDNT LIMITED 1500 SQ FT Charged Paid Credited 75 00 75 00 00 00 00 00 75 00 75 00 00 DATE RESULTS 3' WA 98057 Due 00 00 00 00 0 Extension 75 00 INSPECTOR. 7 /q /a ckiP Ik 1 tin tigiAc, Tw ern Qto Signature of owner or Electrical Contractor X Date Mar 18 09 12 Olp City of Port Angeles Permit Application Building Division/Electrical Inspections 321 East Fifth Street P.O. Box 1150 Port Angeles Washington, 98362 Ph: (360) 417.4735 Fax: (360) 417-4711 Date: 5 I 2 Single Family Dwelling Multi- Family or Commercial* Commercial Addition Alteration Remodel Repair* Plan Review May Be Required, Please Complete Electrical Plan Review Information Sheet Job Address: I i ^l A.l r1.e.* Building Square Footage: OID 1 L' Description of above Pr c^ V ('J I 11'1 S-I-r I WI C .:vl Owner Infp>mation Name: f .01C' Cterfl li)41 Mailin Address: i c g 2 6 City' �C� -F-H P State: L:ni Zip: Phone: n'Ic .Fax .P •.L I License 1 Exp. Unit Charae 93.75 $113.75 $160,00 $205.00 $291.25 2.00 57.50 2,00 72.50 86.25 $116.25 $131.25 75.00 69.00 75.00 50.00 50.00 93.75 80.00 86.25 27.50 57.50 86.25 43.75 stiff yi Rllied Securit 9 4259886452 MAR 1 8 2009 !JQHT DEPT I Dv.. r -�fs_C_ J nr D I DUG( i b DI_ .i d rh.: rc. IC-.6 Total (14 Multiplied by Unit Charoel Service/Feeder 200 Amp. Service/Feeder 201 -400 Amp. Service/Feeder 401 600 Amp. Service /Feeder 601 -1000 Amp. Service /Feeder over 1000 Amp. Branch Circuit W/ Service Feeder Branch Circuit W/O Service Feeder Each Additional Branch Circuit Temp. Service) Feeder 200 Amp. Temp. Service/Feeder 201 -400 Amp. Temp. Service/Feeder 401 -600 Amp. Temp. Service/Feeder 601 1000 Amp. S Portal to Portal Hourly Sign /Outline Lighting 7C rr7l i Signal Circuit/ Limited Energy Commercial Signal Circuit/ Limited Energy 1 2 Family Dwelling Signal Circuit/ Limited Energy Multi- Family Dwelling Manufactured Home Connection Renewable Electrical Energy 5KVA System or Less First 1300 Square Ft. Each Additional 500 Square Ft. or Portion of Each Outbuilding or Detached Garage Each Swimming Pool or Hot Tub Thermostat $.5 Total Signature of owner, electr Gal contractor or electrical administrator 12 Cash i Check II t l i iii �C Date: Credit Card P ell -4., P 2 Contractor Information Name: E1 I r1 S k 4 CL._ if Mailing Address: 3c tk,1 ti„ City' ga i1-1-(,,1 State: 1i-'t Zip: `7S D5 Phone:41 5 v,4 Fax: 425 r�H Gib License 9 P, 3 a/31 C Owner as defined by RCW.19.28.261: (1) Owner will occupy the structure for two years after this electrical permit is finalized. (2) Owner is required to hire an electrical contractor if above said property is for sale, rent or lease. After reading the above statement, I hereby certify that I am the owner of the above named property or a licensed electrical contractor. I am making the electrical installation or alteration in compliance with the electrical laws, N.E.C. RCW. Chapter 19.28, WAC. Chapter 296.468, The City of Port Angeles Municipal Code, and Utility Specifications. Application Number Application pin number Property Address ASSESSOR PARCEL NUMBER Application type description Subdivision Name Property Use Property Zoning Application valuation Application desc New Bank 320 amp service 30 Owner Sound Community Bank 2005 5th ave SEATTLE WA 98121 Permit ELECTRICAL Additional desc Permit pin number 142711 Permit Fee 173 75 Issue Date 3/11/09 Expiration Date 9/07/09 Permit Fee Total Plan Check Total Grand Total INSPECTION TYPE DITCH SERVICE ROUGH IN FINAL COMMENTS ELECTRICAL PERMIT CITY OF PORT ANGELES 360 -417 -4735 09 00000222 854906 110 N ALDER ST 06 30 00 5 6 0125 0000 ELECTRICAL ONLY COMMERCIAL ARTERIAL 0 circuits Contractor SIMPSON ELECTRIC 243036 W HWY 101 PORT ANGELES (360) 457 9270 NEW COMMERICAL Plan Check Fee Valuation Qty Unit Charge Per 30 00 2 0000 ECH 1 00 113 7500 ECH EL 201 400 SRV FEEDER EL BRANCH CIRCUIT W /FEEDER Fee summary Charged Paid Credited 173 75 173 75 00 00 00 00 173 75 173 75 00 1/1, 1 `I 5c Date 3/11/09 WA 98363 DATE RESULTS 7 ctiv/' 1 200 t?oij C- Aw t4% 1 164 V rru a2cir-tf... 01 /09 v 51604 Signature of owner or Electrical Contractor X 00 0 Extension 60 00 113 75 Due 00 00 00 f 31zo(o5 50 FA cd v -IT.lZ .4 IC- $01 OD) N h Date INSPECTOR. 7 City of Port Angeles Permit Application Building Division /Electrical Inspections 321 East Fifth Street P.O. Box 1150 Port Angeles Washington, 98362 Ph: (360) 417 -4735 Fax: (360) 417 -4711 0) Date: 1 2 Single Family Dwelling X Multi Family or Commercial" Commercial Addition I Alteration Remodel I Repair' Unit Charae 93.75 $113.75 $160.00 $205.00 $291.25 2.00 57.50 2.00 72.50 86.25 $116.25 $131.25 75.00 69.00 75.00 50.00 50.00 93.75 80.00 86.25 27.50 57.50 86.25 43.75 Signature 'wner ele trical c or electrical administrator 3 Z/ /D9 RECEIVED MAR 1 0 2009 UGHT DEPT Plan Review May Be Required, Please Complete lectrical Plan Review Information Sheet Job Address: O /V c1 R4/1 //M.O."- JI Building Square Footage: 4 4_0 CO :gri Description of above 32 .ir7 O r(.1 l C i Total (Otv Multiplied by Unit Charge) Service /Feeder 200 Amp. Service /Feeder 201 -400 Amp. Service /Feeder 401 -600 Amp. Service /Feeder 601 1000 Amp. Service/Feeder over 1000 Amp. Branch Circuit W/ Service Feeder Branch Circuit W/O Service Feeder Each Additional Branch Circuit Temp. Service/ Feeder 200 Amp. Temp. Service /Feeder 201 -400 Amp. Temp. Service /Feeder 401 -600 Amp. Temp. Service /Feeder 601 -1000 Amp. Portal to PortatHourly Sign /Outline Lighting Signal Circuit/ Limited Energy Commercial Signal Circuit/ Limited Energy 1 2 Family Dwelling Signal Circuit/ Limited Energy Multi Family Dwelling Manufactured Home Connection Renewable Electrical Energy 5KVA System or Less irst 1300 Square Ft. tach Additional 500 Square Ft. or Portion of Each Outbuilding or Detached Garage Each Swimming Pool or Hot Tub Thermostat Total Lt.)//2.e- R LA r Id, no /Veal ay-442_44o,, or Owner l fDrmation Contractor Infor nation Name: f�tln tDm m u,iy r� 9 in Name: InPS0r) C /?e %it LC,e Mailing Address: 00 S 5 Mailing Address: 03 (e U) rt.(W O. City -e State: kJ ii Zip: r 7' S' :2 I City io )21 /129 .r 1PS State: it) 4 Zip: 3 3 Phone: .27r, -3 8'7 2 Phone: LI,'7 Gi,� 7 rA1e Airt.e. Et License Exp. License Exp. S r/371 S L 9 7 3 g42 Owner as defined by RCW.19.28.261. (1) Owner will occupy the structure for two years aRer this electrical permit is finalized. (2) Owner is required to hire an electrical contractor if above said property is for sale, rent or lease. After reading the above statement, I hereby certify that I am the owner of the above named property or a licensed electrical contractor I am making the electrical installation or alteration in compliance with the electrical laws, N.E.C. RCW. Chapter 19.28, WAC. Chapter 296 -46B, The City of Port Angeles Municipal Code, and Utility Specifications. e 11 6 --el CITY OF PORT ANGELES DEPARTMENT OF COMMUNITY ECONOMIC DEVELOPMENT BUILDING DIVISION 321 EAST 5TH STREET PORT ANGELES WA 98362 Application Number 09 00000139 Date 3/10/09 Application pin number 926478 Property Address 110 N ALDER ST ASSESSOR PARCEL NUMBER 06 30 00 5 6 0125 0000 Tenant nbr name SOUND COMMUNITY BANK Application type description COMM NEW CONST Subdivision Name Property Use Property Zoning COMMERCIAL ARTERIAL Application valuation 6400 Application desc 64 SF DRIVE THRU ATM 32 SF OVERHANG Owner Contractor GALE P QUINN GOLDEN HOME SERVICES INC 560 SE MIDWAY BLVD 3207 PATTEN AVE OAK HARBOR WA 982775018 BREMERTON WA 98312 (360) 675 5859 (360) 782 4829 Structure Information 000 000 64 SF DRIVE THRU ATM 32 SF OVERHANG Permit BUILDING PERMIT COMMERCIAL Additional desc DRIVE THRU ATM OVERHANG Permit pin number 141531 Permit Fee 165 75 Plan Check Fee 107 74 Issue Date 3/10/09 Valuation 6400 Expiration Date 9/06/09 Qty Unit Charge Per Extension BASE FEE 95 75 5 00 14 0000 THOU BL -2001 25K (14 PER K) 70 00 Special Notes and Comments The Fire Department has reviewed the project application and has no comments March 10 2009 11 25 57 AM pbarthol Landscaping plan approved by S Johns 3/10 No land use issues anticipated Public Works Utility Engineering has no requirements for this plan review Other Fees Print T:Forms/Building Division/Building Permit STATE SURCHARGE 4 50 Fee summary Charged Paid Credited Due Permit Fee Total 165 75 165 75 00 00 Plan Check Total 107 74 107 74 00 00 Other Fee Total 4 50 4 50 00 00 Grand Total 277 99 277 99 00 00 Separate Permits are required for electrical work, SEPA, Shoreline, ESA, utilities, private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned for a period of 180 days after the work has commenced, or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any stale or local law regulating construction or the performance instruction. i ature actor or Autho f zed Ag t Signature of Owner (if owner is builder) BUILDING PERMIT INSPECTION RECORD PLEASE PROVIDE A MINIMUM 24 -HOUR NOTICE FOR INSPECTIONS Building Inspections 417 4815 Electrical Inspections 417 4735 Public Works Utilities 417 4831 Backflow Prevention Inspections 417 4886 IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED POST PERMIT IN CONSPICUOUS LOCATION KEEP PERMIT AND APPROVED PLANS AT JOB SITE. Inspection Type Date Accepted By Comments FOUNDATION. Footings Stemwall Foundation Drainage Downspouts Piers Post Holes (Pole Bldgs PLUMBING Under Floor Slab Rough -In Water Line (Meter to Bldg) Gas Line Back Flow Water AIR SEAL. Walls Ceiling FRAMING Joists Girders Under Floor Shear Wall Hold Downs Walls Roof Ceiling Drywall (Interior Braced Panel Only) T -Bar INSULATION Slab Wall Floor Ceiling MECHANICAL. Heat Pump Furnace FAU Ducts Rough -In Gas Line Wood Stove Pellet Chimney Commercial Hood Ducts MANUFACTURED HOMES Footing Slab Blocking Hold Downs Skirting T Forms /Building Division /Building Permit 5 -1X —O 5 —ZS -01 Inspection Type PLANNING DEPT Separate Permit #s SEPA. Parking Lighting I ESA. Landscaping I SHORELINE. FINAL Date Accepted by FINAL Date Accepted by FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/ USE Date Accepted By Electrical 417 4735 Construction R W PW Engineering 417 -4831 I Fire 417 -4653 I I Planning 417 -4750 I I Building 417 -4815 I 7- 13- (°)9 ,1-1-AP Per r Owner GALE P QUINN 560 SE MIDWAY BLVD OAK HARBOR (360) 675 5859 Structure Information Permit Additional desc Permit pin number Permit Fee Issue Date Expiration Date Qty Other Fees Fee summary Permit Fee Total Plan Check Total Other Fee Total Grand Total T Forms/Building Di• ision/Building Pannit CITY OF PORT ANGELES DEPARTMENT OF COMMUNITY ECONOMIC DEVELOPMENT BUILDING DIVISION 321 EAST 5TH STREET PORT ANGELES WA 98362 Application desc 64 SF DRIVE THRU ATM 32 SF OVERHANG k rint Name BUILDING PERMIT DRIVE THRU ATM 141531 165 75 3/10/09 9/06/09 09 00000139 926478 110.N ALDER ST 06 30 00 5 6 0125 0000 SOUND COMMUNITY BANK COMM NEW CONST Application Number Application pin number Property Address ASSESSOR PARCEL NUMBER Tenant nbr name Application type description Subdivision Name Property Use Property Zoning COMMERCIAL ARTERIAL Application valuation 6400 Contractor GOLDEN HOME SERVICES INC 3207 PATTEN AVE WA 982775018 BREMERTON WA 98312 (360) 782 4829 000 000 64 SF DRIVE THRU ATM 32 SF OVERHANG COMMERCIAL OVERHANG Unit Charge Per BASE FEE 5 00 14 0000 THOU BL -2001 25K (14 PER K) Plan Check Fee 107 74 Valuation 6400 Special Notes and Comments The Fire Department has reviewed the project application and has no comments March 10 2009 11 25 57 AM pbarthol Landscaping plan approved by S Johns 3/10 No land use issues anticipated Public Works Utility Engineering has no requirements for this plan review Date 3/10/09 Extension 95 75 70 00 STATE SURCHARGE 4 50 Charged Paid Credited 165 75 165 75 00 107 74 107 74 00 4 50 4 50 00 277 99 277 99 00 an Due 00 00 00 00 Separate Permits are required for electrical work, SEPA, Shoreline, ESA, utilities private and public improvements. This permit becomes:nutl and void if work or construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned for a period of 180 days after the work has commenced, or if required inspections have not been requested within 180 days from the last inspection I hereby certify that have 'read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting ofa permit does resume to give authority to violate or cancel the provisions of any state or.local law regulating construction or the performance of construction. t 4 i 1 Cantr ctor or Au,hoted A ,ent 4) Signature of Ow.wne, (if owner is builder) BUILDING 'PERNIIT-INSPECTION O�N RECORD PLEASE PROVIDE A MINIMUM 24 'HOUR NO TICE FOR INSPECTIONS Building Inspections 417 4815 Electrical Inspections 417 -4735 Public Works Utilities 417 4831 BackfloW- Preventiori Inspections 417 4886 IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED POST PERMIT IN CONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE Inspection Type FOUNDATION Footings Stemwall "7 Foundation Drainage Down Piers Post Holes (Pole Bldgs.) PLUMBING Under Floor Slab Rough -In Water Line (Meter to Bldg) Gas Line Back Flow Water AIR SEAL. Walls Ceiling FRAMING Joists Girders Under Floor Shear Wall Hold Downs Walls Roof Ceiling Drywall (Interior Braced Panel Only) T -Bar INSULATION. Slab Wall Floor Ceiling MECHANICAL. Heat Pump Furnace FAU Ducts Rough -In Gas Line Wood Stove Pellet Chimney Commercial Hood Ducts MANUFACTURED HOMES Footing Slab Blocking Hold Downs Skirting PLANNING DEPT Separate Permit #s Parking Lighting Landscaping T Form 'Building Di" "ision /Building Permit 'Date Inspection Type Electrical Construction R.W PW /Engineering Fire Planning Building l S {fr`i I Q1 c SEPA. ESA. SHORELINE: A ccepted By Comments n. 'FINAL Date Accepted by FINAL Date Accepted by FINAL INSPECT.IONS'REQUIRED F?RIOR TO OCCUPANCY/ USE 417 -4735 41 -4831 417 -4653 417 -4750 417 -4815 Date 7113 /ag I 7115 Accepted I I I rp L C LANDSCAPE PLAN SOUND COMMUNITY BANK PA NEW GRASS EAST GRASS EXPO ATE EAS PLANTE WI NEW PLANT SCALE E%IS PERS EAST TEES NEW LAN CAPE AREA ORB ROCK NED INLET URE RAIN GARD I FUTURE RAIN DEN OPTIO 1 I NOTE ERIS Silt TREES REMAIN RAM LOW MAINTENANCE NAME PUNTS TYP RAM A VARIETY OF PLANTS TNAT WILL YEAR ROUND VARIA ETC EMAY NORTH ALDER STREET INDAUDE SAUL, RAS, ORE CRAP ETC PiAAL RANT SELEC RLANDSCAPE ARC PUNTING AREAS INCLUDE A LOW STATUES GROUND COVER ETC RUMS EARCN NEW SPR NXLE I DRIPCINE PER LANDSCAPE CONTRACTOR Sound Community Bank Port Angeles Branch 10 North Ardor Streel rl Angeles WA 98362 REVISION 1 LANDSCAPE PLAN CONSTRUCTION DRAWINGS TAN Koko Ar. 3/3/09 .avm L1 1 PREPARED 2/19/09 8 26 46 INSPECTION TICKET PAGE 2 CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 2/19/09 ADDRESS 110 N ALDER ST SUBDIV TENANT NBR SOUND COMMUNITY BANK CONTRACTOR GOLDEN HOME SERVICES INC PHONE (360) 782 4829 OWNER GALE P QUINN PHONE PARCEL 06 30 00 5 6 0125 0000 APPL NUMBER 08 00001492 COMM NEW CONST PERMIT BPC 00 BUILDING PERMIT COMMERCIAL REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS BL1 01 1/13/09 JLL BLDG FOUNDATION FOOTING TIME 01 00 1/13/09 AP January 13 2009 8 20 38 AM 1pangrle LANCE 782 4829 FOOTINGS AFTERNOON January 13 2009 4 55 04 PM jlierly BLIS 01 1/15/09 JLL BLDG INSULATION /SLAB 1/15/09 AP February 18 2009 10 40 51 AM 1pangrle SLAB INSULATION February 18 2009 10 41 19 AM 1pangrle BL1 02 1/15/09 JLL BLDG FOUNDATION FOOTING TIME 01 00 1/15/09 AP January 14 2009 5 02 35 PM 1pangrle LANCE 782 4829 FOOTING AFTERNOON February 18 2009 10 41 33 AM 1pangrle BL9 01 2/19/09 LL 1 BLDG SHEARWALL TIME 01 00 February 19 2009 8 24 48 AM 1pangrle LANCE 360 782 4829 SHEARWALL AFTERNOON COMMENTS AND NOTES FEB -10 2009 01 19P FROM TELEOS CITY OF PORT ANGELES r P;cK'e Attn: Building Permit Technician Ca ll 321 E. Fifth St. Port Angeles, WA 98362 (360) 417 -4815 fax (360) 417 -4711 b 1 °y Cuomo) 6 -27 -3 Applicant or Agent C D k Pho $00 b firc Property Owner jakad 54. '1 t v Phon i75 58 5 Property Owner's Address mai Am 1 uM X77 Contractor/Engineer ,4 i, o m i ce Phone Contractor /Engineer's Address Diu i sietAW Wig q 3»- License 6000 tiS y Expires 3 -9- iota E -mail eQ wt Nel PROJECT ADDRESS jj O N A IA•r Pltl, All •IOS A .l I If Sea Parcel Numbe f 0 63o or,c, n 1 l q N Pa-V4.14 1 ck Parcel) Lot Zoning Protect Type 8 Brief Description. Check all that apply fV ew Construction o a ddition o Remodel o Repair a Re -roof o Demolition o Heat System o Other Floor Areas Existingtsq. ft) Basement 1" Floor 2 Floor 3 Floor Garage Carport Covered Porch Deck Shed Other Total footprint of structures Max. height of proposed structures' Will a lawn sprinkler system be installed? Will a fire sprinkler system be installed? Date 3/41/°1 Print Name BUILDING PERMIT APPL A TION Print in ink CI Residential ¥Commercial a Multi- family a Industrial 1 7 1 1 TEtia frT 3v) L-0 v 0 2066520438 o Heat pump o wood burning stove o gas fireplace a pellet stove a other Proposed (so. ft) @5 100 ore Signature TO 13604174711 P 1 For City Use Only Date Received b2-16 -Y4 Permit Ocl Date Approved per sq. ft. 6,# 00 TOTAL VALUATION c16 sq. ft. Lot size 7 r sq. ft. Lot coverage .1 .9 101 1 00 °Zit ft. Occupancy group 0 ;of bedrooms O Occupant load of full baths O Construction type v of half baths I have read and completed this application and know it to be true and correct. I am authorized to apply for this permit and understand that it is my responsibility to determine what permits are required, and to obtain permits prior try working on projects. 114/44 010043ye SO tiej &AMU*, m m_ x c m w o m O z T m cn D C D t7 co o m m m Q 0 rn m FILE m X n CITY OF P© T ANGELES c nstruct!on Plans ihrssuudn bases u l PCP nlans„spP,.lfi- cations and oth ar data shall not prevent the building official from thereafter requiring the correction of errors in said plar,s, specifications and other data, or from preventing building operations being carried on thereunder when in violation of ail codes and ordinances of this jurisdiction. cc, Approval Date 7 i 4 7) By C- 141 0 Q.11— S5e-rj te K AO "A- A 11 N r IN IW i Ca °1 I o ui 1O \c/< VA Z L t `T Ci rW `.G 0 w I I DXI y O W 2 -0 z 1 -C� o 0 N c V. S 033D c3/ rac- m X N C) C) 2 W z y O W CO W 00 W w rn 1=1 NM EAST FRONT STREET p O t Atb A 4 t 7 S 71 4 a 0• (I'SBcnON ATM SHELTER FOUNDATION PLAN SGIlE: V3' 1 -0' 51EFL BOLLARD Fag ARCM 0,85 arrLRE OF ROOF OV'BRFARS ABOVE (2) Os4 (1 BECrION (2) 1,4 FEADER ATM SHELTER ROOF FRAMING_PLAN kALBi 1/2 1 -0 240 ¢IM ,v (3) 100-P NAILS EACn JOST VP v COMn LORIeR BARB O ATM SHELTER BUILDING SECTION SCALE: 12 I -0' Sc NAILS 1, GOVT. °_LAO SEA11E ROOF Al 1502 APA Rosa SIEA5INS (30/15) NNL N Pa NAILS Os EDfi•. RSLD ROOF .0:515 PER -AN M ALP 5.EAn0 ALL Ea131109. NALL5 AS 5n-6 9-EAR rt40.5 PER 5540 77-- H SILL ATE BOL)NS PER 1540. TTP Sound Community Bank Pcrt A.rgeles Branch lie North Alder Street Angeles WA. 98362 ATM SHELTER PLAN SECTION PERMIT DRAWINGS 0 101,19 145 War S9 0 hi! QUANTUM (4 !V tl C I 4 STRUCTURAL CALCULATIONS (Permit Submittal) SOUND COMMUNITY BANK PORT ANGELES ATM SHELTER 110 North Alder Street Port Angeles, WA Quantum Job Number 8148.02 Prepared for SPORE 1514 Bellevue Avenue, Suite 611 Seattle, WA 98122 Prepared by QUANTUM CONSULTING ENGINEERS 1511 Third Avenue, Suite 323 Seattle, WA 98101 TEL 206.957.3900 FAX 206.957.3901 February 4, 2009 I LT I I P...) 11 0 ti ‘t, (0 rz A 4 2b r I tzbl I 0eA 148A g QUANTUM J cou SU1.1111G CtiGItlEERS 1511 HIND AVL, ;lit SUIT 323 SE, ILI V, 98101 TEL :Do 206. A'2.17sv. L- tc .1\1" s y, 4 'OF 4\ 2_ (r, 1',5) t•-•,,It. 4 4- \J it 5(0 LT 0 1 2_ 1 /A 4., I Y- 10 r 1 4- P., U'Z- pro; (1; fp nu. All jgr;/ 0 e0 1: Quantum Consulting Engineers Rev' 500004 User: KW0605835. Ver 5.8.0. 15 Jun.2007 (crt983.2007 Ef7ERCALC Engineer ng Software Description Timber Member Information Timber Section 2z6 Beam Width in 1.500 Beam Depth in 5.500 Le: Unbraced Length ft 2.00 Timber Grade Hem Fir, fto.2 Fb Basic Allow Fv Basic Allow Elastic Modulus Load Duration Factor Member Type Repetitive Status Center Span Data Span Dead Load Live Load Cantilever Span 4.00 16.00 33.00 Results Ratio 0.4983 Span N/ft Wit Uniform Dead Load Uniform Live Load Mmax Center @X= Mmax Cantilever ib Actual Fb Allowable fv Actual Fv Allowable Reactions 0 Left End DL LL Max. DL +LL 0 Right End DL LL Max. DL +LL Deflections Center DL Dell UDefl Ratio Center LL Dell UDefI Ratio Center Total Deft Location UDell Ratio ATM Shelter Roof Joist psi 850.0 psi 150.0 ksi 1,300.0 1.000 Sawn Repetitive ft /ft. 1l/ft ft in -k ft in -k psi, psi psi. psi 8.00 roof fast 16.00 33.00 lbs lbs lbs lbs lbs lbs 3.97 3.68 -4 70 622.0 1,248.3 Bending OK 40.6 150.0 Shear OK 48.00 132.00 180.00 144.00 297.00 441.00 Ratio OIL vc.� at,) Timber Beam Joist in -0.023 4,231.9 in -0.112 853.4 in -0 134 ft 3.872 713.9 Cantilever DL Dell in .0 033 Cantilt. 'er LL Dell in -0.067 Total Cant. Dell in -0.100 UDefl Ratio 984.5 ;ode Ref: 1997/2001 NDS, 2000/2003 IBC, 2003 NFPA 5000. Base allowabtes are user defined Page 1 atm cares.ec. .Calculations 5 0 f Quantum Consulting Engineers R a. 58000 User KW.0605835, Vet 580, ISJu .2007 tc)1083 -2007 ENERCALC Ergmeenng Set ;are Description Timber Section Beam Width Beam Depth Le: Unbracod Length Timber Grade Fb Basic Allow Fv Basic Allow Elastic Modulus Load Duration Factor Member Type Repetitive Status Center Span Data Span Dead Load Live Load Cantilever Span Span Results ATM Shelter Roof Joist Timber Member Information .ode Ref: 1997/2001 NDS, 2000/2003 IBC 2003 NFPA 5000 Base allowables are user defined 2z6 in 1.500 in 5.500 ft 2.00 Hem fir, tto.2 Ratio rcof Joist psi 850.0 psi 150.0 ksi 1,300.0 1.000 Sawn Repetitive ft ft/ft It/f1 ft 8.00 16.00 1Jv t� ©tlia (,4- -1.-JT Timber Beam Joist 4.00 Uniform Dead Load tI /It 16.00 Uniform Live Load #/1t 33.00 0 4983 O'3 bAre {L-i PPc-►+3 Page 1 au ca 'c4 ec. .Catcvat.on s Mmax Center @X= Mmax Cantilever fb Actual Fb Allowable Reactions in -k ft in -k psi psi Left End DL lbs LL lbs Max. DL +LL lbs 0.86 .3.01 -4.70 622.0 1,248.3 Bending OK fv Actual psi 32.1 Fv Allowable psi 150.0 Shear OK 48.00 -33.00 15.00 Right End DL lbs 144.00 LL lbs 165.00 Max. DL +LL lbs 309.00 Deflections Ratio OK Center DL Dell in -0.023 UDell Ratio 4,231.9 Center LL Dell in 0.069 UDell Ratio 1,385.8 Center Total Deft in 0 052 Location ft 5.280 UDell Ratio 1,860.5 Cantilever DL Dell in 0.033 Cantilever LL Dell in -0.247 Total Cant. Deft in 0.2.80 UDell Ratio 343.3 1 -0 of 1 -J L(2/5/2 Linda Pangrle Re Sound Community Bank ATM From Ty Kelly <ty@sporearchitecture corn> To Linda Pangrle <Lpangrle @cityofpa.us> Date 2/5/2009 2.59 PM Subject: Re Sound Community Bank ATM Attachments pastedGraphic tiff PA_C_A9 0 pdf Sound Comm Bank PAngeles ATM shelter cal cs pdf• Sound Comm Bank PAngeles S9 0 pdf CC Hi Linda, Thanks Ty www sporearchitecture corn TY KELLY ty@sporearchitecture corn T 206 940 2145 F 206 652 0438 Aaron Kang- Crosby <aaron @sporearchitecture corn> Here are the plans for the ATM enclosure Floor plans elevations structural drawings and calcs We are also printing full size hardcopies for you that we'll have Gary drop off next time he's there I'll fax you the permit application as well Page 11 (2/2/2009) Linda Pangrle Re Sound Community Bank ATM From Linda Pangrle To: Ty Kelly Date: 2/2/2009 3 58 PM Subject: Re Sound Community Bank ATM Hi Ty I talked with my supervisor Sue, and we would like you to submit a separate permit application for the ATM /overhang. Please submit three sets of building plans for the ATM /overhang. Please enter the valuation of the ATM /overhang (labor material costs) on the permit application. Will the ATM /overhang have any plumbing or mechanical items (vents, heaters, etc.) that need permits? Please continue to move forward with the landscaping plan too. Thanks, Linda Ty Kelly <tvesoorearchitecture.com> 1/30/2009 10 AM Hi Linda, We were wondering if you all had what you need as far as the drive thru ATM? I didn't know if that required a separate permit, or if it was already rolled into our existing permit. Thought I better ask, since I know the bank wants to get that in place soon. I think the goal is for the atm to be functional even before the building is done. Let us know if you require any additional drawings. Thanks, and have a great weekend! Ty www.soorearchitecture.com TY KELLY tv Cal soo rea rc h itectu re. co m T 206 940 2145 F 206 652 0438 Page..1.'I (2/2/2009) Linda Pangrle Sound Community Bank ATM From To Date Subject: cc Hi Linda, We were wondering if you all had what you need as far as the drive thru ATM? I didn't know if that required a separate permit, or if it was already rolled into our existing permit. Thought I better ask, since I know the bank wants to get that in place soon I think the goal is for the atm to be functional even before the building is done Let us know if you require any additional drawings Thanks and have a great weekend! Ty www sporearchitecture com TY KELLY ty@sporearchitecture corn T 206 940 2145 F 206 652 0438 Ty Kelly <ty@sporearchitecture corn> Linda Pangrle <Lpangrle @cityofpa.us> 1/30/2009 1042 AM Sound Community Bank ATM Aaron Kang- Crosby <aaron @sporearchitecture corn> U-E-1` I P 1 o 37 7z t zo oG K l RtAiNions 4 0g- I112, l %X. ec‘" 1 7 PREPARED 1/15/09 8 40 11 INSPECTION TICKET PAGE 3 CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 1/15/09 ADDRESS 110 N ALDER ST SUBDIV TENANT NBR SOUND COMMUNITY BANK CONTRACTOR GOLDEN HOME SERVICES INC PHONE (360) 782 4829 OWNER GALE P QUINN PHONE PARCEL 06 30 00 5 6 0125 0000 APPL NUMBER 08 00001492 COMM NEW CONST PERMIT BPC 00 BUILDING PERMIT COMMERCIAL REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS BL1 01 1/13/09 JLL BLDG FOUNDATION FOOTING TIME 01 00 1/13/09 AP January 13 2009 8 20 38 AM 1pangrle LANCE 782 4829 FOOTINGS AFTERNOON January 13 2009 4 55 04 PM jlierly BL1 02 1/15/09 JLL BLDG FOUNDATION FOOTING TIME 01 00 A IF January 14 2009 5 02 35 PM 1pangrle 1, LANCE 782 4829 FOOTING AFTERNOON COMMENTS AND NOTES PREPARED 1/13/09 8 22 37 INSPECTION TICKET PAGE 4 CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 1/13/09 ADDRESS 110 N ALDER ST SUBDIV TENANT NBR SOUND COMMUNITY BANK CONTRACTOR GOLDEN HOME SERVICES INC PHONE (360) 782 4829 OWNER GALE P QUINN PHONE PARCEL 06 30 00 5 6 0125 0000 APPL NUMBER 08 00001492 COMM NEW CONST PERMIT BPC 00 BUILDING PERMIT COMMERCIAL REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS BL1 01 1/13/09 BLDG FOUNDATION FOOTING TIME 01 00 January 13 2009 8 20 38 AM 1pangrle LANCE 782 4829 FOOTINGS AFTERNOON COMMENTS AND NOTES Signature Application Number Application pin number Property Address ASSESSOR PARCEL NUMBER Tenant nbr name Application type description COMM NEW CONST Subdivision Name Property Use Property Zoning Application valuation Application desc 3 823 SQ FT NEW COMMERCIAL BUILDING Owner GALE P QUINN 560 SE MIDWAY BLVD OAK HARBOR Structure Information Other struct info Permit Additional desc Permit pin number Permit Fee Issue Date Expiration Date Qty Unit Charge Per 4 00 55 0000 HR PW INSPECTION Permit Additional desc Permit pin number Permit Fee Issue Date Expiration Date RIGHT OF WAY Qty Unit Charge Per Extension 1 00 50 0000 ECH RIGHT OF WAY PERMIT 50 00 Special Notes and Comments December 10 2008 3 07 10 PM tdahlqui Provide load calculations with Electrical Permit application Modifications required to City facilities to Separate Permits are required for electrical work, SEPA, Shoreline ESA, utilities private and public improvements This permit becomes null and void if work or construction authorized is not commenced within 180 days if construction or work is suspended or abandoned for a period of 180 days after the work as commenced, or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. T \Policies \I 102 15 [10 /08] r 7 Eract r or (uthorized Agent CITY OF PORT ANGELES PUBLIC WORKS UTILITIES 321 EAST 5TH STREET PORT ANGELES, WA 98362 08 00001492 734956 110 N ALDER ST 06 30 00 5 6 0125 0000 SOUND COMMUNITY BANK COMMERCIAL ARTERIAL 573450 Contractor 000 000 3 823 TOTAL LOT COVERAGE CONSTRUCTION TYPE EXISTING LOT COVERAGE LOT SIZE OCCUPANT LOAD PROPOSED LOT COVERAGE TOTAL LOT COVERAGE NUMBER OF UNITS 139832 50 00 Plan Check Fee 1/06/09 Valuation 7/05/09 Date 1/06/09 GOLDEN HOME SERVICES INC 3207 PATTEN AVE WA 982775018 BREMERTON (360) 782 4829 WA 98312 SQ FT NEW BANK BUILDING 19 18 VB 420 00 22117 00 29 00 3823 00 4243 00 1 00 PUBLIC WORKS INSPECTION SIDEWALKS ADA RAMP DRIVEWAYS 139840 220 00 Plan Check Fee 00 1/06/09 Valuation 0 7/05/09 Extension 220 00 00 573450 Date Signature of Owner (if owner is builder) Date CALL 417 -4831 FOR UTILITY INSPECTIONS PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND 9CCEPTED. POST PERMIT IN A CONSPICUOUS LOCATION r INSPECTION TYPE DATE ACCEPTED COMMENTS PW UTILITIES (Engineering Division) WATERLINE METER SEWER CONNECTION SANITARY STORM SITE DRAINAGE SITE EROSION CONTROL PARKING SIDEWALK CURB GUTTER DRIVEWAY APPROACH BACK -FLOW DEVICE RESIDENTIAL CONSTRUCTION R.W PW/ ENGINEERING 417-4831 FIRE 417 -4653 I PLANNING DEPT 417 -4750 BUILDING 417 -4815 T \Policies\1102 15 [10 /08] PERMIT INSPECTION RECORD KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE YES NO FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY /USE DATE YES NO COMMERCIAL DATE I ACCEPTED I YES I NO CONSTRUCTION R.W PW ENGINEERING I FIRE DEPT I PLANNING DEPT BUILDING ir. Application Number Application pin number Special Notes and Comments be at owner s expense Address numbers shall be plainly visible from the street Address numbers shall be a minimum of six inches high and be of contrasting color from the background A full acceptance test will be required for the fire alarm system A KNOX locking keybox will be required Contact the Fire Department at 360 417 4653 for KNOX keybox ordering information and mounting location December 15 2008 5 03 57 PM sroberds Re construction of a structure in the CA zone at 19% lot coverage Setbacks and lot coverage are good 52 developed parking spaces available on site No land use issues January 6 2009 1 24 42 PM sroberds Building permit is issued to tenant per Chapter 1 Section 105 1 IBC See lease on file with City Building Division December 10 2008 3 04 27 PM tdahlqui Provide load calculations with Electrical Permit application Modifications required to City facilities to be at owner s expense Install a bypass sidewalk at the driveway along 1st Street Remove replace ADA ramp at intersection of Alder 1st Street Install 6 wide sidewalk along west side of Alder Street Replace driveway to meet City Standards on Alder Street INSTALL MAINTAIN EROSION SEDIMENT CONTROL PER CITY STANDARDS OR APPROVED ENGINEER DESIGN PRIOR TO START OF WORK December 10 2008 7 38 11 AM rbecker No fire or lawn sprinkler systems will be installed, so backflows will not be required Other Fees Fee summary T \Policies \1102 15 [10/08] CITY OF PORT ANGELES PUBLIC WORKS UTILITIES 321 EAST 5TH STREET PORT ANGELES, WA 98362 08 00001492 734956 STATE SURCHARGE 4 50 Charged Paid Credited Page 2 Date 1/06/09 Due Permit Fee Total 270 00 270 00 00 00 Plan Check Total 00 00 00 00 Other Fee Total 4 50 4 50 00 00 Grand Total 274 50 274 50 00 00 Separate Permits are required for electrical work, SEPA, Shoreline ESA, utilities private and public improvements This permit becomes null and void if work or construction authorized is not commenced within 180 days if construction or work is suspended or abandoned for a period of 180 days after the work as commenced or if required inspections have not been requested within 180 days from the last inspection I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction Signature of Contractor or Authorized Agent Date Signature of Owner (if owner is builder) Date CALL 417 -4831 FOR UTILITY INSPECTIONS PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED POST PERMIT IN A CONSPICUOUS LOCATION PW UTILITIES (Engineering Division) WATERLINE METER SEWER CONNECTION SANITARY STORM SITE DRAINAGE SITE EROSION CONTROL PARKING SIDEWALK CURB GUTTER DRIVEWAY APPROACH BACK -FLOW DEVICE RESIDENTIAL CONSTRUCTION R.W PW/ ENGINEERING 417 -4831 I FIRE 417 -4653 I PLANNING DEPT 417 -4750 BUILDING 417 -4815 T \Policies\1102 15 [10/08] PERMIT INSPECTION RECORD KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE INSPECTION TYPE DATE ACCEPTED COMMENTS YES NO I I I I I I I I FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE DATE YES NO COMMERCIAL DATE ACCEPTED YES NO CONSTRUCTION R.W PW ENGINEERING I FIRE DEPT I PLANNING DEPT BUILDING I I I Application Number 08 00001492 Date 1/06/09 Application pin number 734956 Property Address 110 N ALDER ST ASSESSOR PARCEL NUMBER 06 30 00 5 6 0125 0000 Tenant nbr name SOUND COMMUNITY BANK Application type description COMM NEW CONST Subdivision Name Property Use Property Zoning COMMERCIAL ARTERIAL Application valuation 573450 Application desc 3 823 SQ FT NEW COMMERCIAL BUILDING Owner Contractor GALE P QUINN GOLDEN HOME SERVICES INC 560 SE MIDWAY BLVD 3207 PATTEN AVE OAK HARBOR WA 982775018 BREMERTON WA 98312 (360) 782 4829 Structure Information 000 000 3 823 SQ FT NEW BANK BUILDING Other struct info TOTAL LOT COVERAGE 19 18 CONSTRUCTION TYPE VB EXISTING LOT COVERAGE 420 00 LOT SIZE 22117 00 OCCUPANT LOAD 29 00 PROPOSED LOT COVERAGE 3823 00 TOTAL LOT COVERAGE 4243 00 NUMBER OF UNITS 1 00 Permit BUILDING PERMIT COMMERCIAL Additional desc 3 823 SQ FT NEW BLDG Permit pin number 138552 Permit Fee 3611 75 Plan Check Fee 2347 64 Issue Date 1/06/09 Valuation 573450 Expiration Date 7/05/09 Qty Unit Charge Per Extension BASE FEE 3260 25 74 00 4 7500 THOU BL -500 001 1M (4 75 PER K) 351 50 Permit Additional desc Permit pin number Permit Fee Issue Date Expiration Date Qty Unit Charge Per T.FonnsBuilding Division/Building Permit CITY OF PORT ANGELES DEPARTMENT OF COMMUNITY ECONOMIC DEVELOPMENT BUILDING DIVISION 321 EAST 5TH STREET PORT ANGELES WA 98362 MECHANICAL PERMIT 138644 153 30 1/06/09 7/05/09 Plan Check Fee 00 Valuation BASE FEE 3 00 14 8000 ECH ME INSTALL 100- FAU 2 00 7 2500 ECH ME VENT FAN 3 00 14 8000 ECH ME INSTALL FLOOR /WALL FURNACE 0 Extension 50 00 44 40 14 50 44 40 ev Nk (5) `C -0< Ari- V14J V '""''7Y c�nJ o Separate Permits are required for electrical work, SEPA, Shoreline, ESA, utilities, private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned fora period of 180 days after the work has commenced, or if required inspections have not been requested within 180 days from the last inspection I hereby certify that 1 have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of co ctitm. 4 6T L, R,3uj2 Date Print Nan(e Sign r or /uthot zed Agent Signature of Owner (if owner is builder) BUILDING PERMIT INSPECTION RECORD PLEASE PROVIDE A MINIMUM 24 -HOUR NOTICE FOR INSPECTIONS Building Inspections 417 4815 Electrical Inspections 417 4735 Public Works Utilities 417 4831 Backflow Prevention Inspections 417 4886 IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED POST PERMIT IN CONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE. Inspection Type FOUNDATION Footings Stemwall Foundation Drainage Downspouts Piers Post Holes (Pole Bldgs PLUMBING Under Floor Slab Rough -In Water Line (Meter to Bldg) Gas Line Back Flow Water AIR SEAL. Walls Ceiling FRAMING Joists Girders Under Floor Shear Wall Hold Downs Walls Roof Ceiling Drywall (Interior Braced Panel Only) T -Bar INSULATION Slab Wall Floor! Ceiling MECHANICAL. Heat Pump Furnace FAU Ducts Rough -In Gas Line Wood Stove Pellet Chimney Commercial Hood Ducts MANUFACTURED HOMES Footing Slab Blocking Hold Downs Skirting Date Accepted By PLANNING DEPT Separate Permit #s SEPA. Parking Lighting I ESA. Landscaping I SHORELINE. FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/ USE Inspection Type Electrical 417 -4735 Construction R W PW Engineering 417 -4831 Fire 417 -4653 Planning 417 -4750 Building 417 -4815 T.Forms /Building Division /Building Permit Comments FINAL Date Accepted by FINAL Date Accepted by Date Accepted By Application Number 08 00001492 Application pin number 734956 Permit PLUMBING PERMIT Additional desc Permit pin number 138651 Permit Fee 142 00 Plan Check Fee 00 Issue Date 1/06/09 Valuation 0 Expiration Date 7/05/09 Qty Unit Charge Per Extension BASE FEE 50 00 9 00 7 0000 ECH PL- EA FIXTURE ON ONE TRAP 63 00 1 00 7 0000 ECH PL- EA INSTALL WATER PIPE 7 00 1 00 15 0000 ECH PL- EA BLDG SEWER 15 00 1 00 7 0000 ECH PL- EA WATER HEATER 7 00 Special Notes and Comments December 10 2008 3 07 10 PM tdahlqui Provide load calculations with Electrical Permit application Modifications required to City facilities to be at owner s expense Address numbers shall be plainly visible from the street Address numbers shall be a minimum of six inches high and be of contrasting color from the background A full acceptance test will be required for the fire alarm system A KNOX locking keybox will be required Contact the Fire Department at 360 417 4653 for KNOX keybox ordering information and mounting location December 15 2008 5 03 57 PM sroberds Re construction of a structure in the CA zone at 19% lot coverage Setbacks and lot coverage are good 52 developed parking spaces available on site No land use issues January 6 2009 1 24 42 PM sroberds Building permit is issued to tenant per Chapter 1 Section 105 1 IBC See lease on file with City Building Division December 10 2008 3 04 27 PM tdahlqui Provide load calculations with Electrical Permit application Modifications required to City facilities to be at owner s expense Install a bypass sidewalk at the driveway along 1st Street Remove replace ADA ramp at intersection of Alder 1st Street Install 6 wide sidewalk along west side of Alder Street Replace driveway to meet City Standards on Alder Street INSTALL MAINTAIN EROSION SEDIMENT CONTROL PER CITY STANDARDS OR APPROVED ENGINEER DESIGN PRIOR TO START OF WORK December 10 2008 7 38 11 AM rbecker No fire or lawn sprinkler systems will be installed so backflows will not be required Other Fees CITY OF PORT ANGELES DEPARTMENT OF COMMUNITY ECONOMIC DEVELOPMENT BUILDING DIVISION 321 EAST 5TH STREET PORT ANGELES WA 98362 STATE SURCHARGE 4 50 Fee summary Charged Paid Credited Due Page 2 Date 1/06/09 Separate Permits are required for electrical work, SEPA, Shoreline, ESA, utilities, private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned for a period of 180 days after the work has commenced, or if required inspections have not been requested within 180 days from the last inspection I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. Date Print Name Signature of Contractor or Authorized Agent Signature of Owner (if owner is builder) T:FormsBuilding Division/Building Permit T.Forms /Building Division /Building Permit BUILDING PERMIT INSPECTION RECORD Inspection Type PLEASE PROVIDE A MINIMUM 24 -HOUR NOTICE FOR INSPECTIONS Building Inspections 417 4815 Electrical Inspections 417 4735 Public Works Utilities 417 4831 Backflow Prevention Inspections 417 4886 IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED POST PERMIT IN CONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE. Inspection Type Date Accepted By FOUNDATION Footings Stemwall Foundation Drainage Downspouts Piers Post Holes (Pole Bldgs PLUMBING Under Floor Slab Rough -In Water Line (Meter to Bldg) Gas Line Back Flow Water AIR SEAL. Walls Ceiling FRAMING Joists Girders Under Floor Shear Wall Hold Downs I Walls Roof Ceiling I Drywall (Interior Braced Panel Only) I T -Bar I INSULATION Slab I Wall Floor Ceiling I MECHANICAL. Heat Pump Furnace FAU Ducts I Rough -In I Gas Line Wood Stove Pellet Chimney I Commercial Hood Ducts I MANUFACTURED HOMES I Footing Slab I Blocking Hold Downs I Skirting I PLANNING DEPT Separate Permit #s SEPA. Parking Lighting I ESA. Landscaping I SHORELINE. Electrical 417 -4735 Construction R W PW Engineering 417 -4831 Fire 417 -4653 Planning 417 -4750 Building 417 -4815 Comments FINAL Date Accepted by FINAL Date Accepted by FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/ USE Date Accepted By Application Number Application pin number T:FormsBuilding Division/Building Permit CITY OF PORT ANGELES DEPARTMENT OF COMMUNITY ECONOMIC DEVELOPMENT BUILDING DIVISION 321 EAST 5TH STREET PORT ANGELES WA 98362 08 00001492 734956 Page 3 Date 1/06/09 Permit Fee Total 3907 05 3907 05 00 00 Plan Check Total 2347 64 2347 64 00 00 Other Fee Total 4 50 4 50 00 00 Grand Total 6259 19 6259 19 00 00 Separate Permits are required for electrical work, SEPA, Shoreline, ESA, utilities, private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned for a period of 180 days after the work has commenced, or if required inspections have not been requested within 180 days from the last inspection I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. Date Print Name Signature of Contractor or Authorized Agent Signature of Owner (if owner is builder) IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED POST PERMIT IN CONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE. Inspection Type FOUNDATION I -15-- Oq 3-L./- Footin I I TL„ L. Stemwall Foundation'Drainage(Downspouts )I Piers Post Holes (Pole Bldgs PLUMBING Under Floor Slab Rough -In Water Line (Meter to Bldg) Gas Line Back Flow Water AIR SEAL. Walls Ceiling FRAMING Joists Girders Under Floor Shear Wad Hold Downs Walls Roof Ceiling Drywall (Interior Braced Panel Only) T -Bar INSULATION Slab Wall Floor Ceiling MECHANICAL. Heat Pump Furnace FAU Ducts Rough -In Gas Line Wood Stove Pellet Chimney Commercial Hood Ducts MANUFACTURED HOMES Footing Slab Blocking Hold Downs Skirting PLANNING DEPT Separate Permit #s Parking Lighting I Landscaping T:Forms /Building Division /Building Permit BUILDING PERMIT INSPECTION RECORD PLEASE PROVIDE A MINIMUM 24 -HOUR NOTICE FOR INSPECTIONS Building Inspections 417 4815 Electrical Inspections 417 4735 Public Works Utilities 417 4831 Backflow Prevention Inspections 417 4886 Date Accepted By -0 1 1- 15 --04 3 �1 I II, -oq Inspection Type Electrical Construction R W PW Engineering Fire Planning Building und art /semuwati F'v ms /(tebar \5/Sjaa J "u- Rebar- 5 16tel Su FINAL Date 1N) j V 1 Accepted by Ti FINAL Date) 1 Accepted by at--L- SEPA. ESA. SHORELINE. Comments FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/ USE Date Accepted By 417 -4735 417 -4831 417 -4653 417 -4750 417 -4815 30-09 i w Co O lit 3j01 81 /01 .S C L- PORT ANGELES LEASE 1 RECEIVED JAN 0 6 2009 CITY OF PORT AN CONES 1 PARTIES This Lease, dated for reference purposes only July 1, 2008, is made by and between Gale Pat Quinn and Betty L Quinn, husband and wife, and Lyndell S (Quinn) Collins, daughter, herein collectively called "LANDLORD" and SOUND COMMUNITY BANK, a corporation incorporated under the laws of the United States, herein called "TENANT' 2 PREMISES. Landlord does hereby lease to Tenant and Tenant hereby leases form Landlord the real property and improvements thereon legally described as follows Lot 4, except the westerly 5 feet and all of lots, 1, 2, 3, 16, and 17, Block 132 of Thomas W Carter's Subdivision of Suburban Lots 11 and 12, Port Angeles Town site as per plat thereof recorded in page 19, records of Clallam County, Washington. 3 TERM. The basic lease term shall be twenty (20) years, plus the partial month, if any, in which the term commences a hereinafter provided, however, that anything to the contrary herein not withstanding, Tenant shall have option to extend the term of this lease for two (2) successive periods of five year each, the first of which shall commence as of the expiration of the initial term hereof. In order to exercise each option, Tenant must notify Landlord of its intent to do so not later than nine (9) months prior to the expiration of the initial term hereof, or the then existing extension period as the case may be. Tenant shall have the right to exercise an option only as long as Tenant is not in default of and of the terms, conditions or payments required hereunder 4 COMMENCEMENT The lease term shall commence October 1, 2008 or sooner, at Tenant's option, provided, however, that anything herein to the contrary notwithstanding, the lease term shall not commence on the date above described unless and until each and every one of the following conditions have been satisfied, a. Memorandums of Lease embodying the terms of this lease and satisfactory m four and substance to Tenant has been recorded. b Tenant has received from each mortgagee trustee or similar party having an encumbrance against the Premises a non disturbance agreement .n recordable form satisfactory in form and substance to Tenant. 5 RENT Tenant agrees to pay Landlord a minimum rent without notice or demand as follows a. Month One and Two No rent due b Months Three to Twenty-four Five Thousand Dollars ($5,000) per month. c Years Three through Five Five Thousand Five Hundred Dollars ($5,500) per month. d. Years Six through Ten. Rent shall be increased in accordance with changes in the Consumer Price Index for years three through five or to Six Thousand Dollars ($6,000) per month, whichever is less. e Years Eleven through Fifteen. 'Rent shall be increased in accorda ice with changes in the Consumer Price Index for years 444 through MPor 2. to Six Thousand Six Hundred Dollars ($6 600) per month, whichever is less o f. Years Sixteen through Twenty Rent shall be increased in accordx e j with changes in the Consumer Price Index for yearsS hrough e or Q to Seven Thousand Two Hundred Sixty Dollars ($7,260) per month, whichever is less. 2 g. Years Twenty -one through Thirty Rent shall be increased in accordance with changes in the Consumer Price Index for years sixteen through twenty Notwithstanding the foregoing rent for years twenty -one through thirty shall increase no less than 5% every five years. Consumer Price Index means the Consumer Price Index for all Urban Consumers in the Seattle Tacoma Bremerton, Washington region as promulgated by the United States Department of Labor 6 ADDITIONAL CHARGES In addition to the minimum rent provided for in Article 5 herein above and commencing at the same time as minimum rent commences, Tenant shall pay all real estate taxes on the Premises .ncluding land, building and improvements thereupon. Said real estate taxes shall include all real estate taxes and assessments that are levied or assessed against the Premises Should there presently be in effect, or should there be enacted during the term of this lease any law, statute, or ordinance levying any tax (other than federal or state income taxes) upon rents, Tenant shall pay any such tax or shall reimburse landlord on demand for any such taxes paid by landlord. 7 PROHIBITED USES Tenant shall not allow the Premises to be used for any improper, immoral, unlawful or objectionable purposes, nor shall Tenant cause, maintain or permit any nuisance in or about the Premises 8 COMPLIANCE WITH LAW Tenant shall not use the Premises or permit anything to be done in or about the Premises which will in any way conflict with any law, statute, ordinance, or governmental rule or regulation now in force or which may hereinafter be enacted. 9 IMPROVEMENTS TO BE LOCATED ON GROUND AREA. Tenant agrees to remodel and improve the existing building located on the Premises. Tenant shall cause to be prepared plans and specifications for construction of the improvements Any and all construction costs shall be borne solely by the Tenant. 10 LIENS Tenant shall keep the Premises free from any liens arising out of any work performed, materials furnished or obligations incurred by Tenant. 3 11 ASSIGNMENT AND SUBLETTING Tenant shall not assign, transfer, mortgage, pledge hypothecate or encumber this lease or any interest therein, and shall not sublet the Premises or any part thereof without the written consent of the Landlord, which consent shall not unreasonably be withheld. Consent to one assignment, subletting, occupation use by any other person shall not be deemed to be consent to any subsequent assignment. 12 HOLD HARMLESS Tenant shall indemnify and hold harmless Landlord against and from any and all claims arising from Tenant s use of the Premises or from the conduct of its business or from any activity, work or other things done, permitted or suffered by the Tenant in or about the Premises and shall further indemnify and hold harmless Landlord against and from any and all claims arising from any breach or default in the performance of any obligation on the Tenant's part to be performed under the terms of this lease, or arising from any act or negligence of Tenant Tenant as a material part of the consideration to Landlord, hereby assumes all risk of damages to property or to persons in, upon of about the premises. 13 LIABILITY INSURANCE Tenant shall at its own expense obtain and keep in force during the term of this lease a policy of comprehension public liability insurance insuring Landlord and Tenant against any liability arising out of the ownership, use, occupancy or maintenance of the Premises and all areas pertinent thereto Such insurance shall be in an amount not less than $2,000 000 for injury or death of one or more persons in any one accident or occurrence with self retention of $1,000,000 Such insurance shall further insure Landlord and Tenant against liability for damage to property of others in an amount of at least $2,000,000 with self retention of $1,000,000 The limit of such insurance shall not, however, limit the liability of the Tenant hereunder Tenant may provide this insurance under a blanket policy provided that said insurance shall have the Landlord's protective liability endorsement attached thereto CASUALTY INSURANCE Tenant, at Tenant's expense, shall keep the buildings and improvements on the Premises insured for the mutual benefit of Landlord and Tenant during the term of this Lease and any extensions thereof against loss or damage by fire and other casualty in an amount sufficient to prevent Landlord or Tenant from 4 becoming a co- insurer of any loss, but in the amount at all times equal to not less than 100% of the then full insurable value of the improvements situated upon the Premises. Full insurable value means the actual replacement value 14 UTILITIES Tenant shall pay for all water gas, heat, light, power, drainage garbage sewer charges, telephone service and all of the services and utilities supplied to the Premises together with taxes thereon. 15 PERSONAL PROPERTY TAXES Tenant shall pay or cause to be paid before delinquency any and all taxes levied or assessed and which become payable during the term hereof upon all Tenant's leasehold improvements, equipment furniture, fixtures and any other personal property located in the Premises. 16 HOLDING OVER. If the Tenant remains in possession of the Premises or any part thereof after the expiration of the term hereof, such occupancy shall be a tenancy from month to -month at a monthly rent in the amount equal to of the 1 /12th the last annual minimum rent plus all other charges payable hereunder and upon all terms hereof applicable to a month -to- month tenancy 17 TENANT'S DEFAULT The occurrence of any one or more of the following shall constitute failure and breach by Tenant a. Failure by Tenant to make any payment of rent or any other payment required hereunder for a period of twenty (20) days after written notice thereof by Landlord. b The failure by Tenant to observe, perform any of the covenants or conditions of this lease other than those described above, where such failure shall continue for a period of thirty (30) days after written notice thereof by Landlord provided that the nature of the default is such that more than thirty (30) days are reasonably 5 required for its cure, Tenant shall not be deemed in default. Tenant promises to diligently pursue the cure until completion. In the event of any such default or breach by Tenant, Landlord may at any time thereafter terminate Tenant s right to possession by any lawful means in which case this lease shall terminate the Tenant shall immediately surrender possession of the Premises to the Landlord. Landlord may, in addition to teiuimating this lease, pursue any other remedy now or hereafter available to Landlord under the laws or judicial decisions of the State of Washington. 18 LANDLORD'S DEFAULT The failure by a Landlord to observe or perform any of the covenants or conditions of this lease where such failure shall continue for a period of thirty (30) days after written notice from Tenant, provided, however, if the nature of the Landlord's default is such that more than thirty (30) days are reasonably required for its cure, then Landlord shall not be deemed to be in default. Landlord promises to diligently pursue the cure until completion, provided, however, that if Landlord is unable to cure such default for a period of thirty (30) DAYS Tenant shall have the option to terminate this lease In the event of any detault or breach by Landlord, Tenant may, in addition to terminating this lease and pursue any other remedy now or hereafter available to Tenant under the laws or judicial decisions of the State of Washington. 19 RECONSTRUCTION In the event fire or any other casualty damages the Premises, during the first fifteen (15) years of this lease, any and all reconstruction shall be at the sole cost and expense of Tenant. In the evenithe Premises are destroyed after the 15 year of the basic term of this lease, reconstruction shall be at Tenant's option. 20 EMINENT DOMAIN If any public authority shall take the whole of the Premises hereby leased under the power of eminent domain, then the term of this lease shall 6 cease as of the date possession and the rent shall be paid up to that date All compensation for the total taking, whether fixes by agreement or judicial award, shall be divided between the Landlord and Tenant as follows a. For the Tenant All amounts attributable to the Tenant s improvements less the residual value thereof at the end of the period of the lease assuming that the Tenant has exercised all options for the extension of the lease b For the Landlord. The balance of the award. If only a part of the leased Premises shall be taken under eminent domain and the remainder of the leased Premises not so taken can be made tenable in the Tenant's opinion for the purpose for which the Tenant has been using the Premises, then this lease shall continue in full force and effect as to the remainder of said Premises, and the terms herein provided shall continue in effect except that the rent shall be reduced in proportion to the amount of the Premises taken. If any portion of the Tenant's improvements is taken, the Tenant shall be awarded such amount as is fixed by the court for damage to the improvements and to the Landlord such amount as the court shall award for the taking of the portion of the fee of the Premises so taken. However, if only land is taken, all damages awarded shall be the Landlord's for the value of the fee of the Premises. In any event, either by partial taking or total taking any and all compensation for the interruption of or loss of business by the Tenant shall be awarded to the Tenant. 21 SURRENDER OF PREMISES Upon the termination of this lease, Tenant shall surrender the Premises and the improvements, provided, however, that the Tenant shall be required to remove any and all trade fixtures, personal property, refuse, garbage, debris, signs and other than Tenant's right to remove aforesaid items, all of the Tenant's right, title and 7 interest in and to the Premises and improvements shall then cease Tenant shall repair any and all damages to the Premises caused by said removal and make all necessary improvements up to city of Port Angeles and /or Washington state, code standard, and Landlord may require inspection approval Landlord may waive the duty to remove and repair as above provide by waiver in writing as requested by Tenant thirty (30) days prior to the expiration of the term at the Landlord's option. In the event the tenant does not rebuild the existing building at the time of surrender the existing building will be removed and the property will be in readiness to begin new construction. If the existing building is rebuilt or a new building is placed on the property this condition does not apply 22 SIGNS The Tenant shall not erect or install any signs, advertising media, window or door lettering contrary to the City of Port Angeles codes 23 FIRST RIGHT OF REFUSAL TO PURCHASE PREMISES If Landlord decides to sell the Premises, Landlord shall offer to Tenant the right to purchase the Premises subject to this lease The notice shall set forth the price at which Landlord will sell the premises, which shall be the fair market value of the Premises subject to the lease If the parties cannot agree upon the fair market value as the purchase price for the Premises for a period of forty five (45) days following the date of the Landlord's notice sell the premises to Tenant, the parties shall make a good faith effort to establish the fair market value of the Premises through mediation in accordance with the provisions of Rule 39 1 of the Local Rules of the United States District Court for the Western District of Washington. If the parties are unable to establish a purchase price through mediation, the purchase price shall be established by arbitration. All expenses of 8 mediation and /or arbitration shall be borne equally by the parties, except each party will be responsible for its expenses and the expenses of its representatives participating in the mediation and /or arbitration and the fees and expenses of attorneys, accountants, appraisers, or other experts employed by the party in connection with such mediation and /or arbitration. The purchase of the Premises by Tenant shall be closed within one hundred eighty (180) days after the date the option is exercised. At closing, title to the premises shall be conveyed by Landlord to Tenant by statutory warranty deed, is to be free of all encumbrances or defects Rights reserved in federal patents or state deeds building or use restrictions general to the area, other than platting and subdivision requirements, utility easements, other easements not inconsistent with Tenant's intended use and reserved oil and /or mineral rights, shall not be deemed encumbrances or defects Encumbrances to be discharged by Landlord shall be paid from the purchase money at the date of closing. Landlord shall provide to Tenant at closing a Standard Owner's Policy of Title Insurance, with coverage in an amount not less than the purchase price, insuring Tenant's good, marketable and indefeasible title to the Premises in fee simple absolute, subject only to standard printed exceptions appearing in the title policy form, and nondelinquent general property taxes payable during the year in which the closing date occurs General real estate taxes and assessment installments due during the year of the closing and rents shall be prorated between Landlord and Tenant as of the Closing Date Landlord shall pay all real property transfer taxes, recording fees and the premium for the Title Policy Landlord and Tenant shall each pay one -half (1/2) of the escrow fee 24 GENERAL PROVISIONS a. Plats and Riders Clauses, plats, riders and addendums. If any, affixed to this lease are a part thereof. 9 b Waiver The waiver by Landlord of any term, covenant or condition herein contained shall not be deemed to be a waiver of any such term, covenant, or condition or any subsequent breach of the same or any other term, covenant or condition herein contained. c Marginal Headings The marginal headings and articles, titles to the articles of this lease are not a part of the lease and shall have no effect upon the construction or interpretation of any part hereof d. Time Time is of the essence of this lease and each and all of its provisions which performance is a factor e Successors and Assigns The covenants and conditions herein contained, subject to the provisions as to assignment, appl9 to and bind their heirs, successors, executors, administrators and assigns of the parties hereto f Ouiet Possession. Upon Tenant paying the rent reserved hereunder and observing and performing all covenants, conditions and provisions to be observed and performed by Tenants part, Tenant shall have quiet possession of the Premises for the entire term hereof subject to all the provisions in this lease g. Prior Agreements This lease contains the rent reserved hereunder and observing and performing all covenants, conditions and provisions on Tenant s part to be observed and performed, Tenant shall have quiet possession of the Premises for the entire term hereof subject to all the provisions in this lease h. Inability to Perform. This lease and the obligation of the Tenant hereunder shall not be affected or impaired because the Landlord is unable to fulfill any of its obligations herein below or is delayed in doing so if such inability or delay in caused by 10 reason of strike, labor trouble acts of God or any other cause beyond the reasonable control of the Landlord in partial invalidity Any provision of this lease which shall prove to be invalid, void or illegal in no way affects, impairs or invalidates any other provision hereof and such other provisions shall remain in full force and effect. 1 Cumulative Remedies No remedy or election hereunder shall be deemed exclusive, but shall wherever possible be cumulative with all other remedies at law or in equity Choice of Law• the laws of the State of Washington shall govern this lease k. Attorney's Fees In the event of any action or proceeding brought by either party against the other under this lease, the prevailing party shall be entitled to recover for the fees of its attorneys in any such action or proceeding, including cost of appeal if any, in such amount as the court may adjudge reasonable as attorney's fees. 1. Subordination and Attornment: Upon request of the Landlord, Tenant will in writing, subordinate its rights hereunder to the lien of any mortgage or deed of trust, and bank, insurance company or any other lending institution now or hereafter in force against the Premises and to all advances made or hereafter to be made upon the security thereof so long as prior to or contemporaneous with the execution for said subordination agreement, Tenant has received from the lending institution a non disturbance agreement providing that so long as Tenant duly performs its obligation and is not in default, its possession of the Premises will not be disturbed in the event of a foreclosure, and further, providing that the non disturbance agreement is binding upon the successors, heirs, and assigns of said bank, insurance company or institutions. 11 The provision of this article to the contrary notwithstanding and so long as Tenant is not in default hereunder this Lease shall remain in full force and effect for the full term hereof. m. Notices All notices and demands which may be required or permitted to be given by either party to the other shall be in writing. All notices and demands by the Landlord to Tenant or Tenant to Landlord shall be sent by United States Mail, postage prepaid, addressed the Tenant /Landlord to the address herein below or to any other place as Tenant/Landlord may from time to time designate To Landlord at: Pat and Betty Quinn 1781 7 Ave Oak Harbor, WA 98277 With a copy to Lyndell Collins 4708 Camano Place Anacortes, WA 98221 To Tenant at: Laura Lee Stewart, President /CEO Sound Community Bank Administrative Office 2005 5 Ave 2 Floor Seattle, WA 98121 Mailing Address PO Box 34155 Seattle, WA 98124 With a copy to Porter, Kohli LeMaster, P S 1325 4 Avenue, Suite 940 Seattle, WA 98101 25 TENANT'S RIGHT TO CANCEL It is understood that Tenant shall have a period of two one hundred eighty (270) days from final execution of this lease in which to get all 12 the necessary governmental permits and approvals to operate Tenant s proposed business on the subject property In the event the Tenant is not successful, it may terminate this lease by giving Landlord notice in writing within thirty (30) days prior to commencement of rent. Dated the day and year first written above LANDLORD Afa% Gale Pat inn Date yndell S Quinn Collins Date STATE OF WASHINGTON ss. COUNTY OFZ'L /D DS' Date TENANT SOUND -OM By C__ Its Date /v/ STATE OF WASHINGTON ss. COUNTY OF; iU I certify that I know or have satisfactory evidence that Laura Lee Stewart, President /CEO Sound Community Bank is the person who appeared before me, and she acknowledged that she signed this instrument and acknowledged it to be her free and voluntary act for the uses and purposes mentioned in the instrument. Dated this 7/'t day of P/f)L 200 I 411711 ‘0 Pried Name C/. l L ')t vi t <L J1-P Notary Public in and for Ow Stat r Washington, residing at >t%+- My appointment expires Z `z 7-C I certify that I know or have satisfactory evidence that Gale Pat Quinn and Betty L Quinn, husband and wife, are the persons who appeared before me, and they acknowledged that they signed this 13 ITY B R instrument and acknowledged it to be their free and voluntary act for the uses and purposes mentioned in the instrument. Dated this I A PuBoo z* N ■N 9 6 ,06 -1 1, 111 Op W AS I f I STATE OF WASHINGTON ss. COUNTY OF day of 2008 rf-.14111 Printed Name Notary Public in and for the State o Washington, residing at 5 My appointment expires to ,c j m> y vcl I certify that I know or have satisfactory evidence that Lyndell S Quinn Collins is the person who appeared before me, and she acknowledged that she signed this instrument and acknowledged it to be her free and voluntary act for the uses and purposes mentioned in the instrument. Dated this day of 2008 Printed Name Notary Public in and for the State of Washington, residing at My appointment expires 14 December 19 2008 Thank you W A S H I N G T O N U S A Public Works Utilities Department Ty Kelly Teleos Design 810 3` Ave Suite 324 Seattle WA 98104 Re Plan Review Comments Sound Community Bank, 110 North Alder Street, Port Angeles Ty Plans submitted do not adequately address a number of requirements under the City's Urban Services Standards 1 A site erosion and sediment control plan will need to be submitted for review and approval 2 Further building inspections will not occur until the plan is approved and erosion control measures are installed inspected and accepted by Public Works Utilities Engineering Division In addition please have your engineer address and revise the details to your plans to address the following 1 6 wide sidewalk along the west side of Alder Street from tie in at First Street to tie in at Front Street will be required (See Attached #1) 2 The mid -block driveway /sidewalk along the west side of Alder Street will need to meet driveway detail per City Standard detail (See Attached #2) 3 The ADA ramp and curb at the northwest corner of Alder Street will need to be reconstructed to meet current requirements for accessibility (See Attached #3) 4 The existing sidewalk at the First Street driveway entrance will need sidewalk transitions to accommodate pedestrian bypass (See Attached #4) If you have any questions or concerns please contact Roger Vess at 417 -4812 or rvess rncitvofoa.us Sincerely Roger Vess Assistant Civil Engineer Attachments. 1 -4 Map Public Works Docs1Sound Community Bank 110 So Alder St.doc Phone 360- 417 -4805 Fax 360- 417 -4542 Website www cityofpa.us Email publicworks @cityofpa.us 321 East Fifth Street P 0 Box 1150 Port Angeles WA 98362 -0217 NOTES. EXPANSION JOINT B 6' MIN. 6' MIN. 1 2X SLOPE I Cry \''Z(. 4" M/N /MUM COMPACTED SUBGRADE AND 'i /i�, COMPACTED GRANULAR MATERIAL A A COMPAC SUBG RADE AND FOR 6" AT DRIVEWAYS FINE GRAD /NG AS NECESSARY 4 MINIMUM COM TEGRNLAR MATERIAL PACD AU SECTION A -A 6" A T OR!VEWA YS FOR RNE GRADING AS NECESSARY SECTION B -B 1 SIDEWALK LOCATION 70 BE APPROVED BY CITY ENGINEER. 2. EXPANSION JOINTS SHALL BE ASPHALT IMPREGNATED JOINT MATERIAL 3 EXPANSION JOINTS SHALL BE 1/4 THCK, FULL DEPTH AND AT 15'-0" INTERVALS 4. DUMMY JOINTS SHALL BE 1/$" THICK, 1" DEEP AND AT 5 =0" INTERVALS 5. ALL UTILITY POLES METER BOXES ETC IN SIDEWALK AREA SHALL HAVE EXPANSION JOINT MATERIAL (FULL DEPTH) PLACED AROUND THEM. 6. ALL JOINTS SHALL BE CLEAN AND EDGED. 7 EXPOSED AGGREGATE OR SPECIAL SURFACE 7REA7MENT WORK NOT ALLOWED IN RIGHT -O' -WAY. EC DRIVEWAY AND SIDEWALK SHALL BE SEPARATED BY EXPANSION JOINTS 9. CONCRETE S7•/ALL BE CLASS 3000. 10. HERBICIDE TO BE PLACED UNDER PAWNS, CURB AND SIDEWALK PR /OR 70 PLACING OF MATERIALS 11. SIDEWALK ELEVA77ON SHALL BE BASED ON 2x SLOPE PROJECT/ON FROM TOP OF CURB. 12 SIDEWALK MOTHS SHOWN ARE FOR RESIDEN7TAL AREAS COMMERCIAL AND DOWNTOWN AREAS MOTHS SHALL BE 10' AND 14' RESPECT77VELY 13. ANY OENA77CN FROM THESE MINIMUM STANDARDS REQUIRES PRIOR APPROVAL BY CITY ENGINEER. CALL FOR FORM INSPECTION BY CITY 24 HOURS PR /OR 70 POURING CONCRETE APPROVED BY CITY ENGINEER FILE NAME SIDEWALK. ,NWG PA 4 SIDEWALK WITH PLANTING STRIP SEE NOTE it/ I 2X SLOPE 5' M /N. STANDARD DETAIL A A DUMMY JOINT j EXPANSION JOINT SIDEWALK AT CURB SEE NOTE #1 ALL WORK AND MATERIAL TO BE IN ACCORDANCE WITH THE CURRENT WASHINGTON STATE DEPAR TMENT OF TRANSPORTATION "STANDARD SPECIFICA TIONS FOR ROAD, BRIDGE, AND MUNICIPAL CONSTRUCTION" DATE E�ISED 3/15/06 EXPANSION JOINT DUMMY JOINT R. O. W. SIDEWALK INSTALLATION 0� pORT44, Itzta mss y RKS Aso STANDARD DETAIL FULL CONCRETE CURB AND GUTTER (BEYOND) SIDEWALK SURFACE (BEYOND) 6 PEDESTRIAN DEPRESSED CONCRETE CURB TRA VEL WA Y CROSSING DRI VEWA Y NOTES. SECTION A -A 6 SIDEWALK AT DRIVEWAY APPROACH, TYP 1 THE PEDESTRIAN TRA VEL WAY SHALL HAVE A MAXIMUM CROSS SLOPE OF 48:1 (2 TRANSI17ON RAMP FROM DRIVEWAY TO SIDEWALK MAX SLOPE 12: 1(8.3%) 4? GRADE TO MATCH EXISTING DRIVE SEE NOTE 5 2 INSTALL RAMPS ON BOTH SIDES OF THE DRIVEWAY AS SHOWN ON THE PLANS. RAMPS SHALL BE AS LONG AS NECESSARY TO PROVIDE A MAXIMUM SLOPE OF 12: 1 PARALLEL AND PERPENDICULAR TO THE EXISTING PLANE ON WHICH THE RAMP IS TO BE CONSTRUCTED. 3 CEMENT CONCRETE SHALL BE CLASS 3000, MIN. 6 THICK INCLUDING RAMPS 4 ASPHALT I M P R E G N A T E D E X P A N S I O N J O I N T F U L L DEPTH A T B A C K O F C U R B AND E V E R Y 20 F E E T A T TRANSVERSE JOINTS. JOINT MATERIAL NOT REQUIRED AT BACK OF CURB IF RAMP AND /OR DRIVEWAY IS POURED SEPARATELY CREATING A COLD JOINT 5 CRACK JOINTS EVERY 5 FEET IN WALK. 6. HERBICIDE (RESIDUAL) TO BE APPLIED BEFORE POURING CONCRETE 7 EXPOSED AGGREGATE OR SPECIAL SURFACE TREATMENT NOT ALLOWED IN RIGHT OF WA Y CALL FOR FORM INSPECTION BY CITY 24 HOURS PRIOR TO POURING CONCRETE. APPROVED BY I DATE CITY ENGINEER REVISED FILE NAME. DROP DR/LEWAYDWG ALL WORK AND MATERIAL TO BE IN ACCORDANCE WITH THE CURRENT WASHINGTON STATE DEPARTMENT OF TRANSPORTA710N "STANDARD SPECIFICATIONS FOR ROAD, BRIDGE, AND MUNICIPAL CONSTRUCTION 3/15/06 DRIVEWAY INSTALLATION SIDEWALK THROUGH DRIVEWAY m 3/8" EXPANSION JOINT (TYP.) (SEE STD. PLAN F 3) T b a 0 CEMENT CONCRETE PEDESTRIAN IA N CU RB '(SEE STD. PLAN F -1) SIDEWALK DIUS POINT OF SIDEWALK RAMP AND CURB RETURN CURB, OR CURS AND GUTTER CEMENT CONCRETE SIDEWALK RAMP TYPE 2A DETECTABLE WARNING PATTERN AREA SHALL BE YELLOW, IN COM- PLIANCE WITH STD. SPEC. 8- 14.3(3) PLAN D E F MIN. 1 5/8" 6/8" 7118" 2 3 1 12" 3(4' 0 7/8" 17/18" RAMP CENTERLINE EW RAMP TYPE 2A LAYOUT 6' 0" MIN. 2% CEMENT CONCRETE J SIDEWALK ELEVATION CEMENT CONCRETE PEDESTRIAN CURB TRUNCATED DOMES (SEE NOTE 7) (SEE STD. PLAN F -1) DETECTABLE WARNING PATTERN DETAIL SECTION 6' 0" MIN. LANDING 2' SECTION SEE CONTRAfT FOR CURB RETURADIUS DETECTABLE JARRING PATTERN (SEE DETAIL) 0'I TOP OF ROADWAY 'CEMENT CONCRETE CURB A GUTTER (SEE NOTE 5) SIDEWALK CURB, OR CURB AND GUTTER CEMENT CONCRETE SIDEWALK RAMP TYPE 2B FLUSH TOP OF 1,7– l ROADWAY /CEMENT CEMENT CURB GUTTER CONCRETE IEEE NOTE 51 DEPRESSED SIDEWALK DETECTABLE WARNING PATTERN (SEE DETAIL) RADIUS POINT OF SIDEWALK RAMP AND CURB RETURN 2 6' e o' VARIES 3' 0" TO "A' TYPE 2A RAMP RAMP CENTERLINE CEMENT CONCRETE PEDESTRIAN CURB (SEE STD, PLAN F-1) CROSSWALK VARIES 8' 0' TO 'B" I L'. RAMP 3/8" EXPANSION I JOINT (TYP.) L LANDING (SEE STD. PLAN F-3) SECTION O 3/8" EXPANSION JOINT (SEE STD. PLA 2' 8" VARIES 2' 8" TO 'C" TYPE 28 L PLAN VIEW SIDEWALK RAMP TYPE 28 LAYOUT VARIES 8' 0" TO "B" SEE CONTRACT FOR CURB RETURN RADIUS CEMENT CONC. SIDEWALK RAMP TYPE 2B DETECTABLE WARNING PATTERN (TYP.) (SEE DETAIL) LI ISOMETRIC VIEW RADIUS A e C (AT CURB FACE) 20 FEET 4' 5 1/4' 8' 10 1/2' 1 3' 8 1/2" 30 FEET I 3' 10' T 8' 13' 2 114' 40 FEET I 3' 7" 7' 2" 1 3' 0" 60 FEET 13' 5 12° 8' 10 3/4' 12' 10 112" 60 FEET 13' 4 12' 8' 8 3/4" 12' 9 12' 70 FEET 13' 3 3/4' 6' 7 112" I 2' 9° BO FEET 13' 3 114' 6' 8 12' 12 B 12' 90 FEET 13' 2 3/4' 8' 5 12" 2' 8 1/4' I 100 FEET 13' 2 1/2" 6' 5" 2' 8" INTERMEDIATE RADII CAN BE INTERPOLATED NOTES 1 The Type IA Ramp is used to provide access to two cross- walks only when it Is infeasible to provide a separate ramp for each crosswalk. 2. The Type 2B Ramp Layout requires two (2) of this bid item: 'Cement Conc. Sidewalk Ramp Type 2B" The bid Item does not Include the adjacent Curb or Curb 8 Gutter), the Sidewalk between Ramps, or the Cement Conc. Pedestrian Curb. 3. Ramp slopes shall not be steeper than 12H:1 V 4. Avoid placing drainage structures, junction boxes or other obstructions In front of ramp access areas. 6. Curb Gutter is shown, see the Contract Plans for the curb design specified. See Standard Plan F 1 for curb details. 6. See Std. Plan F 3 for sidewalk Joint placement and details. 7 Detectable warning patterns may be created by any method that will achieve the truncated dome dimensions and spacing shown. EXPIRES MAY 16, 2005 SIDEWALK RAMP TYPES 2A 28 WITH LAYOUTS STANDARD PLAN F -3b SHEET I OF 1 SHEET q RgvEp n 2 0 S .,km OEnn 1 DAM WadOnolon 1N'• Op. MM d TNnapalWNan NOTES. A 12' MIN. JO' MAX CALL FOR FORM INSPECTION BY CITY 24 HOURS PRIOR TO POURING CONCRETE. APPROVED BY CITY ENGINEER/ FILE NAME DRII/EWAYVWG DRIVEWAY APRON STANDARD DETAIL A R/W D '3,/35 E VI SED 3/15/06 M/N DEPRESSED CURB FLUSH AT CUTTER 6' COMPACTED SUBGRADE AND COMPACTED GRANULAR MATERIAL FOR FINE GRADING AS NECESSARY SECT/ON A—A s'—o— M /N. EXPANSION JOINTS MEET SIDEWALK OR FUTURE SIDEWALK GRADE 2% MAX REPLACE SIDEWALKS W1T74 6' CONCRETE /N DRIVEWAY AREA 2% MAX /MUM SLOPE IN SIDEWALK AREA =1x5/ 5' MIN. SEE NOTE #10 1. DRIVEWAY LOCA 710N TO BE A r D BY CITY ENG /NEV 2. WHEN SIDEWALK IS NOT PRESENT, D' ACH SHALL CONS 'UCTFD TO MEET FUTURE SIDEWALK GRADE. 3. SIDEWALK CROSS SLOPE SHALL NOT EXCEED 2% IN DRIVEWAY AND "ASS AREAS. 4. DRIVEWAY APRON AND SIDEWALK SHALL BE CONCRETE AND SEPARATED FROM OTHER CONCRETE WORK USING EXPANSION ✓01N7S 5. HERBICIDE TO BE PLACED UNDER PA CURB AND SIDEWALK PRIOR TO PLACING OF MA 7ERIALS. 6. SIDEWALKS CURB AND CUTTER PER CITY STANDARD PLANS. 7 EXPOSED AGGREGATE WORK OR SPECIAL SURFACE TREATMENT NOT ALLOWED IN RIGHT OF WAY 8. TRANSVERSE EXPASNSION JOINT(S), FULL DEPTH, SHALL BE AT INTERVALS NOT TO EXCEED 15 FEET AND BE EOUALL Y SPACED IN DRI VFWA Y APRONS. 9. CONCRETE SHALL BE CLASS 3000. 10. DRIVEWAY PA MG MA TERIALS, OTHER THAN CONCRETE. MAY BE USED BETWEEN THE SIDEWALK AND THE R/W WITH CITY ENGINEER APPROVAL. 11. EXPANSION JOINTS SHALL BE 1/4' THICK, FULL DEPTH, ASPHALT IMPREGNA TED JO /NT MATERIAL. 12. SIDEWALK WIDTHS SHOWN ARE FOR RESIDENTIAL AREAS COMMERCIAL AND DOWNTOWN AREA WIDTHS SHALL BE 10' AND 14 RESPECTIVELY 13. ANY DE FROM THESE MINIMUM STANDARDS REQUIRES PR /OR APPROVAL BY CITY ENG /NEER. ALL WORK AND MATERIAL TO BE IN ACCORDANCE WITH THE CURRENT WASHINGTON STATE DEPARTMENT OF TRANSPORTATION STANDARD SPECIFICATIONS FOR ROAD, BRIDGE, AND MUNICIPAL CONSTRUCTION" DRIVEWAY INSTALLATION tkr r:rrr -'r.,. kt, 4, f„ ?4. 4 f- 'V ,g,. •-.Ft a s.„.. .4:: •.f.; rri•-.' -.el ••-.4••• •4.`•`, 1;1, r,T,' ,1„ ,7,-:S :t .•r••,- l'," 4" fi V 5:,-:., 1 :'4'• 4, 71• IL: r ';i• tty) V, 4 t A 4 t to',), t =4, 00ti t .r Z.A• ;3‘ attar ,.tr- !..St 4 '•-t.r tf •1• a 1 5 r: •1 t ars c4, I. .4, k1'.'rr- •••i•,: i.l I..-. 4' sr tZr!" (12/16/2008) Linda Pangrle 08 -1492 From Sue Roberds To Linda Pangrle Date 12/15/2008 5 06 PM Subject: 08 -1492 Linda' I signed off for Sound Community Bank because I'm quite sure there won't be a problem. Please don't issue without property owner's acknowledgement. It can be by e-mail, or letter it doesn't matter Thanks for the good work! Sue (12/8/2008) Linda Pangrie Re just checking in Page 1 From. Linda Pangrie To: Ty Kelly Date: 12/8/20081.39 PM Subject: Re just checking in Hi, It was nice meeting you and Aaron too I have some good news for you. The Fire Marshal and Building Inspector have both approved your plans already There are four more departments that still need to give their approval. Things are looking good for your project. I'll let you know ASAP if we need anything else from you. Thanks, Linda Ty Kelly <tvc&soorearchitecture.com> 12/8/2008 1 23 PM Hi Linda, It was great to meet you last week. Let us know if there's anything you need from us. Just got to thinking with the holidays coming up and people being gone, we'll want to track down any answers you may need as soon as we can. Thanks! Ty www.soorearchitecture.com TY KELLY tvCalsoorearch itecture. com T 206 940 2145 F 206 652 0438 2066520438 v Roiv <A Cc- 059 vo6- 6 14 0 2 1 1 1' -6 POQT D�si� UILDING PERMIT vv�t Ke u For City Use Only 0 -140 -214 )Date Received 17,.. Rrc wie Permit H Date Approved Phone 204 21.6 -3r32 I CITY OF PORT ANGELES Attn: Building Permit Technician 321 E. Fifth St., Port Angeles, WA 983 (360) 417 -4815 fax (360) 417 -4711 (50t GA IP FL o L\p 1A01. TO 13604174711 P 2 a C L *er li re, Corr y �s�o LICATION Print in ink Applicant or Agent Property Owner GAI p 4,AzN N Phone Property Owner's Address 540 sE PilD wAH QLVD C/,k H a -bgr, wA 4s217 5d 12 Contractor /Engineer &ot.710 1.1 orq. SER.viCeT LANGE Fl rci Phone 360 -1 r2 1 11'29 Contractor /Engineer's Address 3 201 Pak -Fein Ave_ g re•rner o r 1 t,,r A 9 g 3 I Z License Gold ,0 h s R'12- 6 Expires 3 —g -2610 PROJECT ADDR S t 1 o P o .-r i 1„1(- on -4his pLLr Parcel Numbe 0 6 O) 56 /ls fl- f, b 6 60 /2S u y 14 ∎tql Lot Zonin C A on erect Type Brief Description; o Residential tkommercial Multi family o Industrial Check all that apply o New Construction o Addition 11 Remodel o Repair o Re -roof a Demolition o Heat System )4 Heat pump o wood burning stove o gas fireplace o pellet stove o other o Other Floor Areas Basement 1" Floor 2 Floor 3' Floor Garage Carport Covered Porch Deck Shed ,P As h� Other s c 7-7 Nap 9 �a`� w K� q y t� '1o g Y� o Yw Total footprint of structures 4. 211 3 sq. ft. INLLND T•RSrt EN6LOSr4g. ANP aVEtttliM bi Max. height of proposed structures 2q ft. Will a lawn sprinkler system be installed? NV Will a fire sprinkler system be installed? N 0 NEI•�'1�ArJK.' ANGti, KEtPi 4 ExtSTIW(a Swig/ Fool' PRf►y aq Gin/440r guitcot.11- K IN G I k4U s, Ex istina (so. ft.1 (pposed (so. ft.) bi0 ,0) oar 1 3,A00 3 a 5-0 per sq. ft. -57;1150 c,\\0 K\ 0 N) ��Q� TOTAL VALUATION 5 950 Lot size Vim ,sq. ft. Lot coverage :mo ,2 ,2 117 f Datum 06 3o 000, OILS 19 I a a Zo Occupancy group y of bedrooms Occupant load of full baths Construction type V- 13 of half baths I have read and completed this application and know it to be true and correct. I am authorized to apply for this_permit and understand that it is my responsibility to determine what permits are required, and to obtain permit prio working on projects. aQ6_ g140 2,1/-15 Date o5 r1 r J/ Print Name e1 l ti signature T:FormslBuilding DivlsionBldg Permit Appl. -2006 Code.doc V sgwur C 40' 6' 7' 5' 12' EXIST POWER POLE EXIST, SIGN EXIST. TRASH ENCLOSURE REPAIR AS NEEDED EXIST. TREES 18 30'00 "E 159.97' EXIST. WATER METER f 6 -0' OVERHANG W Z J PROJECT SITE: 110 NORTH ALDER STREET PORT ANGELES, WA 98362 X I EXIST 4 Y�' 1 r IDR41N LINE fVf R I Y`� EX I ST. ELI PE F 4MP I N FIEt D)�F 13 2 3 4 5 6 7 1819 i10� 12 O I R €4AS N REMAIN A�N 17 18 19 20 21 22 23 24 25 26 27 28 29 1 Rs 63, i e Doi N 18 °30'00 "E 105.88' NORTH ALDER STREET SITE PLAN SOUND COMMUNITY BANK PA EXISTING PARKING TO REMAIN. REPAIR AS NEEDED, TYP 20' -0" y— EXIST MANHOLE NO'S ED Rt L,? (t/ FR%Fy�N F /eCOv 2 0 10 20 30 177 6" N 18 °30'00 "E 139.97' EXIST. CONC. STEPS 50 I 33 152' -6" 3 2 L= ;03 I 26 48 39 l In I 0 IN is" If'- I 1 4 9 48 47 46 45 44 43 I 35 36 37 38 39 X93& N 18 °30'00 "W 10' I N I I I 40 41 42 I 1 1 EXIST MANHOLE EXIST CATCH BASIN, TYP EXIST SIGN 21 QUANTUM C O S O L O 6 E N G S E E R S STRUCTURAL CALCULATIONS (Permit Submittal) SOUND COMMUNITY BANK PORT ANGELES 110 North Alder Street Port Angeles, WA Quantum Job Number 8148.01 Prepared for SPORE 1514 Bellevue Avenue, Suite 611 Seattle, WA 98122 Prepared by- QUANTUM CONSULTING ENGINEERS 1511 Third Avenue, Suite 323 Seattle, WA 98101 TEL 206.957.3900 FAX 206.957.3901 November 17, 2008 P WAS 1 o z r 2180V W tes, �lSTE¢ rti ONAL Expires 05/29/ 21 QUANTUM STRUCTURAL DESIGN CRITERIA SOUND COMMUNITY BANK PORT ANGELES 110 N ALDER STREET PORT ANGELES WA 98362 QUANTUM JOB NUMBER. 8148 01 CODE CRITERIA. BUILDING CODE BUILDING DEPARTMENT WIND CRITERIA SEISMIC ZONE SNOW SOILS CRITERIA. ALLOWABLE BEARING PRESSURE FROST DEPTH MATERIALS CRITERIA. CONCRETE (28 DAY STRENGTH). FOUNDATION /S 0 G WALLS REINFORCING STEEL. GRADE 60 CONSULTING ENGINEERS STRUCTURAL STEEL. WIDE- FLANGE SECTIONS A -992 MISCELLANEOUS SECTIONS A -36 TUBE SECTIONS A -500 WELDING WOOD FRAMING. 2X, 3X, 4X FRAMING MBRS 6X FRAMING MBRS PARALLAM BEAMS GLULAM BEAMS LSL MEMBERS BEAMS HEADERS LSL MEMBERS STUDS COLUMNS WOOD SHTG 2006 INTERNATIONAL BUILDING CODE CITY OF PORT ANGELES 100 MPH EXPOSURE 'C' BUILDING CATEGORY II Kn 10 Iw 10 SDC D SITE CLASS D R =65 IE= 1 0 S =112 S, =047 Sp 079 S DI 048 25 PSF 1 500 PSF 12 MIN f'c =3 000 PSI f'c =3 000 PSI Fy =60 000 PSI Fy =50 000 PSI Fy =36 000 PSI Fy =46 000 PSI Fy =70 000 PSI HF #2 OR DF #2 DF #1 2 0 E WS PARALLAM PSL 24F V4 (V8 CONT AND CANT MBRS) 1 55 E LSL 1.3 E LSL .APA RATED 1 STRUCTURAL DESIGN CRITERIA I SOUND COMMUNITY BANK PORT ANGELES 110 N ALDER STREET I PORT ANGELES, WA 98362 QUANTUM JOB NUMBER. 8148.01 I ASSEMBLY WEIGHTS I ROOF LOADS COMMENTS GRAVITY SEISMIC. 111 MEMBRANE ROOFING 2 2 PSF 2 2 PSF i/z PLYWOOD SHEATHING 1 5 PSF 1 5 PSF ROOF JOISTS 24 0 C 3 1 PSF 3 1 PSF I R30 INSULATION 10 PSF 10 PSF 5/8 GWB 2 LAYERS 5.2 PSF 5.2 PSF SPRINKLERS 3 0 PSF 1 0 PSF I LIGHTS DUCTS 1 0 PSF 0 5 PSF MISCELLANEOUS MECHANICAL 3 0 PSF 1 5 PSF PARTITIONS 5 PSF ROOF DL 20 0 PSF 21 0 PSF SL 25 PSF I WALL LOADS GRAVITY SEISMIC. SIDING 2.3 PSF i h PLYWOOD SHEATHING 1 5 PSF FRAMING 2X6 16 0 C 1 7 PSF INSULATION 0 5 PSF l GWB 2 2 PSF MISCELLANEOUS MECHANICAUELEC 1 8 PSF BRICK VENEER (WHERE OCCURS) 40 0 PSF 10 0 PSF 50 PSF W/ VENEER 1 1 1 1 1 go'b), lab c Go k\1 cvs 70 ,L.-v.oj j ,-t -i tvIW Or �53 r+" ls ©r l "05a SA.1 Sd 0 7i `1S .'sd� k c 5 112-00F AM aU RJ 1_1 31 -1 sc 37' o (o --1 2x( ,lt s w 20 PL t ?sPe LL Lg.12. I 40' Jo ts 4a' ov4 -lo,, t 11 1 2 S r Jo t sT ii 42 5' w 4sd 20" TJ I Lq o e Z¢ O L. 8 807. 1.81 Y23,1- Cos t4Ptc 1 "at ?X(o w�11 /5'4 r L. 20 7J l L°1 o e IcT V 0, c. I3 e..1.6@ crt 'L}o/r, t L '11 t2-17 co 5r proms 1'13 QUANTUM 1511 THIRD AVENUE SUITE 323 SEATTLE, WA 98101 TEL 206.957.3900 FAX 206.957.3901 www.quantumce.com 2o rJ 1 L40 1(o 4 0. c �et1 "7o°la 4 t c. 2 l S .e /255 cos I.4Ven 2 08 CONSULTING ENGINEERS Sr. 6 project —1- 1.1!=b s client sty-- r? s date sr designer checked by o OI project no. jQ 2 sheet W rha TJ -Beam? 6.30 Serial Number 7005107658 User 2 9/2/2008 2:32:19 PM Page 1 Engine Version: 6.30.14 A Member Slope: .2512 Roof Slope.2512 All dimensions are horizontal. SUPPORTS: DESIGN CONTROLS: Shear (lbs) Vertical Reaction (lbs) Moment (Ft -Lbs) Live Load Defl (in) Total Load Defl (in) PROJECT INFORMATION: Sound Community Bank Port Angeles RJ1 Copyright 2007 by iLevel Federal Way WA. TJI' and TJ -Beam? are registered trademarks of iLevel e -I Joist Pro' and TJ -Pro' are trademarks of iLevel M. \Teleos \Sound Community Bank Port Angeles \37 span sms 20" TJI /L90 24" o/c THIS PRODUCT MEETS OR EXCEEDS THE SET DESIGN CONTROLS FOR THE APPLICATION AND LOADS LISTED LOADS: Analysis is for a Joist Member Primary Load Group Snow (psf): 25.0 Live at 115 duration, 20.0 Dead Maximum Design Control 1646 1639 3151 1646 1646 3076 15058 15058 18900 1.043 1.830 1.878 2.439 Result Passed (52 Passed (54 Passed (80 Passed (L/421) Passed (U234) 37 Input Bearing Vertical Reactions (Ibs) Detail Other Width Length Live/Dead/Uplift/Total 1 Stud wall 3.50' 3.50' 925 /740 0/1665 2 Stud wall 3.50' 3.50' 925 /740/0/1665 End, TJI Blocking 1 Ply 20' TJI /L90 End, TJI Blocking 1 Ply 20' TJI /L90 -Web stiffeners are required at support(s): 1 2. See TJI JOIST INSTALLATION INFORMATION for nailing requirements. Location Rt. end Span 1 under Snow loading Bearing 2 under Snow loading MID Span 1 under Snow loading MID: Span 1 under Snow loading MID Span 1 under Snow loading Product Diagram is Conceptual. Deflection Criteria: STANDARD(LL:U240,TL:U180). Bracing(Lu): All compression edges (top and bottom) must be braced at 5 4 o/c unless detailed otherwise. Proper attachment and positioning of lateral bracing is required to achieve member stability OPERATOR INFORMATION: Scott Tinker Quantum Consulting Engineers 4 grit-5 ADDITIONAL NOTES: IMPORTANT! The analysis presented is output from software developed by iLevel? iLevel? warrants the sizing of its products by this software will be accomplished in accordance with iLevel? product design criteria and code accepted design values. The specific product application, input design loads, and stated dimensions have been provided by the software user This output has not been reviewed by an iLevel? Associate. -Not all products are readily available. Check with your supplier or iLevel? technical representative for product availability THIS ANALYSIS FOR iLevel? PRODUCTS ONLY! PRODUCT SUBSTITUTION VOIDS THIS ANALYSIS. Allowable Stress Design methodology was used for Building Code IBC analyzing the iLevel? Custom product listed above. (Minimum cut length) (Overall horizontal length) x 1.000 7/16' z •r• TJ -Beam? 6.30 Serial Number 7005107658 User. 2 9/2/2008 3:12:21 PM Page 1 Engine Version: 6.30.14 1 THIS PRODUCT MEETS OR EXCEEDS THE SET DESIGN CONTROLS FOR THE APPLICATION AND LOADS LISTED /1Member Slope: .2512 Roof Slope.25:12 All dimensions are horizontal. LOADS: Analysis is for a Joist Member Primary Load Group Snow (psf): 25.0 Live at 115 duration, 20.0 Dead SUPPORTS: Input Bearing Width Length 1 Stud wall 3.50' 3.50' 2 Parallam PSL Beam 5.25 Hanger DESIGN CONTROLS. Maximum 1417 1417 13940 Shear (lbs) Vertical Reaction (lbs) Moment (Ft -Lbs) Live Load Defl (in) Total Load Defl (in) PROJECT INFORMATION: Sound Community Bank Port Angeles RJ2 Design Control 1417 3151 1417 3076 13940 18900 1 107 1.968 1.992 2.624 M: \Teleos \Sound Community Bank Port Angeles \40 span sms 20" TJI /L90 19.2" o% Vertical Reactions (lbs) Live/Dead/Uplift /Total 795/636/0/1432 805/644/0/1448 Result Passed (45 Passed (46 Passed (74 Passed (U427) Passed (L/237) 10' 2 Top Mount Hanger MIT420 .25/12 0 N/A No 0 Nailing for Support 2: Face: 4 -10d Top 4 -10d Member 2 -N10 Copyright 2007 by iLevel Federal Way WA. TJI' TJ -Beam? and Parallam? are registered trademarks of iLevel e -I Joist Pro and TJ -Pro' are trademarks of iLevel Simpson Strong -Tie's Connectors is a registered trademark of Simpson Strong -Tie Company Inc Product Diagram is Conceptual. Ply Depth Nailing Detail Depth N/A N/A N/A End, TJI Blocking 1 20.00' N/A Top Mount Hanger -Web stiffeners are required at support(s): 1 2. See TJI JOIST INSTALLATION INFORMATION for nailing requirements. HANGERS: Simpson Strong -Tie? Connectors Support Model Slope Skew Reverse Top Flange Flanges Offset Top Flange Slope Support Wood Species N/A Location Rt. end Span 1 under Snow loading Bearing 2 under Snow loading MID Span 1 under Snow loading MID Span 1 under Snow loading MID Span 1 under Snow loading OPERATOR INFORMATION: Scott Tinker Quantum Consulting Engineers Other 1 Ply 20' TJI /L90 None Deflection Criteria: STANDARD(LL:U240,TL:U180). Bracing(Lu): All compression edges (top and bottom) must be braced at 5' 7' o/c unless detailed otherwise. Proper attachment and positioning of lateral bracing is required to achieve member stability ADDITIONAL NOTES: IMPORTANT! The analysis presented is output from software developed by iLevel? iLevel? warrants the sizing of its products by this software will be accomplished in accordance with iLevel? product design criteria and code accepted design values. The specific product application, input design loads, and stated dimensions have been provided by the software user This output has not been reviewed by an iLevel? Associate. -Not all products are readily available. Check with your supplier or iLevel? technical representative for product availability THIS ANALYSIS FOR iLevel? PRODUCTS ONLY! PRODUCT SUBSTITUTION VOIDS THIS ANALYSIS. Allowable Stress Design methodology was used for Building Code IBC analyzing the iLevel? Custom product listed above. (Minimum cut length) (Overall horizontal length) x 1.000 7/16' 6■48 0) Ma TJ -Beam? 6.30 Serial Number 7005107658 User: 2 9/2/2008 3:10:34 PM Page 1 Engine Version: 6.30.14 rl All dimensions are horizontal. SUPPORTS: 1 Stud wall 2 Stud wall Input Width 3.50" 3.50' DESIGN CONTROLS. Shear (lbs) Vertical Reaction (lbs) Moment (Ft -Lbs) Live Load Defl (in) Total Load Defl (in) Bearing Length 3.50" 3.50' PROJECT INFORMATION. Sound Community Bank Port Angeles RJ3 THIS PRODUCT MEETS OR EXCEEDS THE SET DESIGN CONTROLS FOR THE APPLICATION AND LOADS LISTED A Member Slope: .2512 Roof Slope 2512 LOADS: Analysis is for a Joist Member Primary Load Group Snow (psf): 25.0 Live at 115 duration, 20.0 Dead Vertical Reactions (Ibs) Detail Live/Dead/Uplift/Total 708/567/0/1275 708/567/0/1275 Maximum Design Control 1263 1258 3151 1263 1263 3076 13284 13284 18900 1 196 2.105 2.153 2.806 Deflection Criteria: STANDARD(LL:U240,TL:U180) Bracing(Lu): All compression edges (top and bottom) must be braced at 5 9' lateral bracing is required to achieve member stability Copyright 2007 by iLevel Federal Way WA. TJI' and TJ -Beam? are registered trademarks of iLevel e -I Joist Pro's and TJ Pro' are trademarks of iLevel M. \Teleos \Sound Community Bank Port Angeles \42 5 span sus 20" TJI /L90 16" o/c ;2 6 Other End, TJI Blocking 1 Ply 20" TJI /L90 End, TJI Blocking 1 Ply 20' TJI /L90 -Web stiffeners are required at support(s): 1 2. See TJI JOIST INSTALLATION INFORMATION for nailing requirements. Result Passed (40 Passed (41%) Passed (70 Passed (L/422) Passed (L/235) Location Rt. end Span 1 under Snow loading Bearing 2 under Snow loading MID Span 1 under Snow loading MID Span 1 under Snow loading MID Span 1 under Snow loading Product Diagram is Conceptual. o/c unless detailed otherwise. Proper attachment and positioning of ADDITIONAL NOTES: IMPORTANT! The analysis presented is output from software developed by iLevel? iLevel? warrants the sizing of its products by this software will be accomplished in accordance with iLevel? product design criteria and code accepted design values. The specific product application, input design loads, and stated dimensions have been provided by the software user This output has not been reviewed by an iLevel? Associate. -Not all products are readily available. Check with your supplier or iLevel? technical representative for product availability THIS ANALYSIS FOR iLevel? PRODUCTS. ONLY! PRODUCT SUBSTITUTION VOIDS THIS ANALYSIS. Allowable Stress Design methodology was used for Building Code IBC analyzing the iLevel? Custom product listed above. (Minimum cut length) (Overall horizontal length) x 1 000 7/16' OPERATOR INFORMATION: Scott Tinker Quantum Consulting Engineers 4 ,0rq s.o1 R5 g 0 1 M✓ o`'II �C� c g) Ito' Jo,sl- n I (0' t (0I ,.J( G6i,k -7 iV CI h� 1511 THIRD AVENUE SUITE 323 SEATTLE, WA 98101 TEL 206.957.3900 FAX 206.957.3901 www.quantumce.com .‘12 T► fZ- 2' w 4O a(2') epti n is k -(5 X) 150 6 Q wQ 63 x12 2 213 ti�h Li u 05" 2J S UPS' RooF -3o1ST w 15 ftq?1, 404 n a c Q w t✓l-x Z 2 4 x 11 3 k' QUANTUM CONSULTING EN SC& PO 2T project T v client v 2-4" L 80 A I GINEERS AaCq C 27 2x8 e 24 4 o c V 125" NT 'O Z3, 2t 2.x-12 1{.F e- 24 J°A t .gq'" 32.7 Mntt 3 ci 1» /14, ROOD date 5T designer checked by (cD.0 4 1 .l5 0 l8� 5145 of R project no. sheet 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 TJ -Beam? 6.30 Serial Number' 7005107658 20" TJ 1 ?/L65 24" o% User 2 9/2/2008 3:55:33 PM Pagel Engine Version: 6.30.14 THIS PRODUCT MEETS OR EXCEEDS THE SET DESIGN CONTROLS FOR THE APPLICATION AND LOADS LISTED /l Member Slope: .2512 Roof Slope.2512 LOADS. Analysis is for a Joist Member Primary Load Group DESIGN CONTROLS. Overall Dimension: 22' All dimensions are horizontal. PROJECT INFORMATION: Sound Community Bank Port Angeles RJ4 16' SUPPORTS: Input Bearing Vertical Reactions Ms) Ply De th JNaiying Detail Other Width Length Live/Dead/Uplift/Total D7pth 1 Parallam PSL Beam 5.25' Hanger 405 274 0 679 1 20.00 N/A Top Mount Hanger None 2 Stud wall 5.25 5.25' 758 606 0 1364 N/A \I/A N/A Overhang 1 Ply 20' TJI /L65 -Web stiffeners are required at support(s): 1 2. See TJI JOIST INSTALLATION INFOFMATION for nailing requirements. HANGERS: Simpson Strong Tie? Connectors Snow (psf): 25.0 Live at 115 duration, 20.0 Dead Nailing for Support 1 Face: 4 -N10 Top 4 -N10 Member 2 -N10 Support Model Slope Skew Reverse ltop/FI Top Flange Support Wood Flange Offset Slope Species 1 To p Mount Hanger MIT320 .25/12 0 N/A No 0 N/A Maximum Design Control Result Location Shear (lbs) -804 747 3151 Passe 24 Rt. end Span 1 under Snow loading Vertical Reaction (lbs) 1364 1364 5009 Pas d (27 Bearing 2 under Snow loading Moment (Ft -Lbs) 2276 2276 13271 Pa. sed (17 MID Span 1 under Snow ALTERNATE span loading Live Load Defl (in) 0.045 0.622 Passed (2L/999 Right OH under Snow ALTERNATE span loading Total Load Defi (in) 0.081 1.023 /Passed (L/999 MID Span 1 under Snow ALTERNATE span loading Deflection Criteria: STANDARD(LL:L/240,TL:U180). Bracing(Lu): All compression edges (top and bottom) r3aust be braced at 8' 4 o/c unless detailed otherwise. Proper attachment and positioning of lateral bracing is required to achieve member stability./ The load conditions considered in this design analysis include alternate member pattern loading. ADDITIONAL NOTES: 1 IMPORTANT! The analysis presented is outpu from software developed by iLevel? iLevel? warrants the sizing of its products by this software will be accomplished in accordance with iLevel? product design criteria and code accepted design values. The specific product application, input design loads, and stated dimensions have been pr vided by the software user This output has not been reviewed by an iLevel? Associate. -Not all products are readily available. Chk with your supplier or iLevel? technical representative for product availability THIS ANALYSIS FOR iLevel? PRODU$ TS ONLY! PRODUCT SUBSTITUTION VOIDS THIS ANALYSIS. Allowable Stress Design methodology/was used for Building Code IBC analyzing the iLevel? Custom product listed above. (Minimum cut length) (Overall h000ntal length) x 1.000 7/16' Copyright 2007 by iLevel Federal Way WA. TJI' TJ -Beam? and Parallam? are registered trademarks of iLevel e -r Joist. Pro and TJ -Pro's are trademarks of iLevel Simpson Strong -Tie? Connectors is a registered trademark of Simpson Strong -Tie Company Inc M. \Teleos \Sound Community Bank Port Angeles \16 span plus cant sms 1 6 a Product Diagram is Conceptual. OPERATOR INFORMATION: Scott Tinker Quantum Consulting Engineers 4 gi4S I 2`7 QooF F2AM1tJG I (Co.4- 11 UP f i 2 Sao C Lei2esm Y 4eivea. 8 Ise {b 45 Z Z 338A- 12, 1 35" Mix w so n, 2 32 4- t' 11 I 0FFIGE IL Hy pe s' (4t 45 2J >z w� a 34 M Z 1108 k- 4), 1 3 1 1 L 2 [.S w 45Jy( 2 6;2" M 1cA 2 Ib 1O22At QUANTUM 1511 THIRD AVENUE SUITE 323 SEATTLE, WA 98101 TEL 206.957.3900 FAX 206.957.3901 1 E L O S www.quantumce.com client CONSULTING ENGINEERS 3C6- o(L7 !-AN -t EL S project d>c 8 2 (Cq =1 Is) \1416.4 2 C1 1-Vh. Maw 32 4 w V X L Cep us) V 4-10 u- e 6 Mhtlo,-, tl 4- 6, 157. r 6. 35' 7 1 2-°)0 VSO 5' (5x GL 1b rek A ‘t8 d X0 12'` M tittow 1°11 0 817. r 0 59 r2-34 4— ND 6ocip V `J' St /t5 Z G '1r re t c¢, Qi- AT 0 31 "r312- I I 0-1 0 8 /2.-/ 914-8 9 148 0 1 date project no. ST RA designer sheet checked by lc) GLB Worksheet fv 190 psi Cd 1 15 fb 2400 psi E 1800 ksi L =r 26.51ft. Allowable Strengths b (in.) d (in.) V (k.) M (k -in) El (k -in 3.125 9 3.125 10.5 3.125 12 3.125 13.5 3.125 15 3.125 16.5 3.125 18 3.125 19.5 3.125 21 410 4 78 5.46 6.15 6.83 7.51 8.19 8.88 9.56 5.125 9 6.72 5.125 10.5 7.84 5 125 12 8.96 5.125 13.5 10.08 5.125 15 11.20 5.125 16.5 12.32 5.125 18 13.44 5.125 19.5 14.56 5 125 21 15.68 5.125 22.5 16.80 5.125 24 17 92 5.125 25.5 19.04 6.75 9 8.85 6.75 10.5 10.32 6.75 12 11.80 6.75 13.5 13.27 6.75 15 14 75 6.75 16.5 16.22 6.75 18 17 70 6.75 19.5 19.17 6.75 21 20.65 6.75 22.5 1 22.12 6.75 24 1 23.60 6.75 25.5 1 25.07 6.75 27 1 26.55 116.4 158.5 207.0 262.0 323.4 389.2 459.1 534.5 615.4 191 0 257 4 331 7 414.9 506.8 607 4 716.6 834.3 960.5 1095.0 1237.91 1389.01 246.0 329.7 425.0 531.6 649.4 778.3 918.2 1069.0 1230.6 1403.0 1586.1 1779.7 1983.8 341,719 542,637 810,000 1,153,301 1,582,031 2,105,684 2,733,750 3,475,723 4,341,094 560,419 889,924 1,328,400 1,891,413 2,594,531 3,453,321 4,483,350 5,700,185 7,119,394 8,756,543 10,627,200 12,746, 932 738,113 1,172,095 1,749,600 2,491,130 3,417,188 4,548;277 5,904,900 7,507,561 9,376,763 11,533,008 13,996,800 16,788,642 19,929,038 1 Roo 1= 1 w0214_ C 1 J TL I k�x� w 4 art •3- 7_ 2 1 I 1 �/1- VA e, x.12 1 ce c I t` Z F!-ex spAct, H r f� 21st w t 4-Sft' (1-21) S 35' cr-t- 50 k h P-Ne. I $e-Xlc-1.'‘ 'OJT $A-TY'1Q.00MS 15 w 4-5 t-z 1 01 S cl QUANTUM 1511 THIRD AVENUE SUITE 323 SEATTLE, WA 98101 TEL 206.957.3900 FAX 206.957.3901 www.quantumce.com (2.) 21Uo cf ppk re�� CONSULTING ENGINEERS S GPI For2.4 project TE LLS client site, ,c Gi 1. �G I I s) v gklow (0 12i"- At Oi t o I- {,n 800 fir° _D 3°I 2°1 5118 11 L (c -I 15) V0.11ow t. C 2 °l0 Mnb1 k' h 10P7o A-= 0 "l 1." y; use- S X21 1 sauce_ 04ev-4A A crtef (c0 =1 1s) Vti1lo,.. lo og MAllow 41 °I h 827. aT H u SE c /Y x 1 s CaL. 1v roLe-e p dr o 44:1'4 A Rev tt 114105 6 1 /3/(78 o 148 01 date project no. sT RJ O designer sheet checked by 4 S4 S' Pe-A-CAS VA) raLre PLIA \9-1 5.25 2 00111 NM MI 111111 MI MI I•1111 MI MI MI NM OM MI iow 4 :1 2 .4 e it 6*P91t AndeleS 01b 4..''' /1 4 6 4tY, 6 I s 4 .9, 101 'Ut IN, 6' '06 z 7f t i 2— 11 'I 11- ir- i f i ltde r tro,, ij 4 7 St 1 r f I''' 1 -e.-Patt, A :i aikm.pic II 11 I National Park fi i' 1 1,0 Frpbell. Ave ir "I'; iin il q EL 2 1 S 'crivner Rct li 1; Port Angeles, Washington, United States Port Angeles Harbor 40 I \O° v\ I 110 N Alder St, Port Angeles, WA. 110 N Alder St Port Angeles, WA 98362 ladvoy .1 Marsden-Rd' ;I Juan de Fuca "Trait St Strait of 1(.ern ri'r .,t r Pearce Rd' I; Copyright 1988-2004 Microsoft Corp. and/or its suppliers. All rights reserved. http://www.microsoft.corn/streets/ Copyright 2003 by Geographic Data Technology, Inc. All rights reserved. 2004 NAVTEQ. All rights reserved. This data indudes information taken with permission from Canadian authorities Her Majesty the Queen in Right of Canada. !Bifly Rd o mi 0.5 1 1.5 Project Name Sound Community Bank Port Angeles Date Fri Aug 29 14 5912 PDT 2008 Conterminous 48 States 2006 International Building Code Latitude 48 11 Longitude -123 41 Spectral Response Accelerations Ss and S1 Ss and S1 Mapped Spectral Acceleration Values Site Class B Fa 1 0 ,Fv 1 0 Data are based on a 0 01 deg grid spacing Period Sa (sec) (g) 0.2 1 121 (Ss, Site Class B) 1 0 0 466 (S1, Site Class B) Conterminous 48 States 2006 International Building Code Latitude 48 11 Longitude 123.41 Spectral Response Accelerations SMs and SM1 SMs FaSs and SM1 FvS1 Site Class D Fa 1 052 ,Fv 1 534 Period Sa (sec) (g) 0.2 1 179 (SMs, Site Class D) 1 0 0 715 (SM1, Site Class D) Conterminous 48 States 2006 International Building Code Latitude 48 11 Longitude -123 41 SDs 2/3 x SMs and SD1 2/3xSM1 Site Class D Fa 1 052 ,Fv 1 534 Period Sa (sec) (g) 0.2 0 786 (SDs, Site Class D) 1 0 0 477 (SD1, Site Class D) C c 0 121 200G I P M v,s 082 0SG [214-q845x46C -3 1'x 25Pt2 (143)(35)] 1200¢ 4-1/2. wAv.* w st w n8 63 3 ,o4 -f S 55`.] 1 14 Ole a I el. 6F 43 1 Vw 4 2T 4 ps 3o 4 X t 1 23 Ex.(' G 1(0' 2°, a K zr 1 0 Iw 4 23 1'Sao ?v; iS d`�rZ ©Go s� 1 �O t 1 2 CD 00 8.(0' 25.8 1� 8 col 3 e• La In 43' 84 S' Nis —Iv.J r WiNA M�nb l 1 1 I r It J QUANTUM I CONSULTING ENGINEERS 1 SC� 1 /4 c-, t,-s 9/41°,5 g14-8 01 1511 THIRD AVENUE Project date project no. 1 SUITE 323 �T L4 hi& SEATTLE, WA 98101 designer sheet TEL 206.957.3900 FAX 206.957.3901 'PLC: OS 1 www.quantumce.com client checked by 1 1 1 1 1 LJ 1c 5 la (4-(ti 2) t2igi- (25,5' 10.5' iq 'G (17 2') h 12 9 A2(0.3g)j SEiSMtG C)bw� '�11 W it.) D Govv'12145 E/W 1 1 1 I 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1_-Pc L PE (&r� rJo ftrH /soLrrtA i4'+'+ Io' 32' v s Z 3 /94o iy 1 t 22 9 14 L,,,41/4 UP�1Fr I23 (lo KOPI 4 20 ti i lilt 2 WA ST@)T �f s emen Tor 5ovkl 1230 25.35 Q Wit. -4 1 1 1' 2 1 e ltom) q '154 S.25 t215 (1 151 Gt4 C Cc 4 2'IS e...4t1 Ve 2'15 w lt Up� 5,25, pIt 1 222(10)- 9- 1,2001- XI)] I WFk Ii4M 22Zo (4 3 1 355 222 Ib 2220 QUANTUM 1511 THIRD AVENUE SUITE 323 SEATTLE, WA 98101 TEL 206.957.3900 FAX 206.957.3901 www.quantumce.com "J5 -7.g&k 123 -kll gooF V r Ib �r/X32,)J I�� Z 37t4 6432' 1355 CONSULTING ENGINEERS (0 C 2z ti A-. s /I 4 <sw -4 2 5 42o 15 /2 ci? Sc g Po9.-r project T�LtrvS client 113u1 GMSTIIo (4 5q •`4ac (4200r yet 243P rlfel e 3 a G- D02_ (2229 t o (4o powrJS P ..b CO✓tir_XvA.{ivC) 9141 8 oI date project no. ST LS designer sheet checked by L A=1 t. DES (=kJ C..AST W STJ \L. 12 !O& I S9Ccf fl n ga wo os wq-(4- 12 u�L Vvo u_ G 33 11 1 (07 PI- (.022v 11� ,Sr Co22c7 Ib z x sw 4x l% 16 £D( .I4F; 2. c hb� GMoU) FveLe DIA C t L 1 co T/G d To? 0' OP l i l r 141 i,t (311.) I, 47O Ih G MST ICo c4 Ird,A Aeaci io pop o(iKrrt 6220 lb 141btCt (12' +12') 20o4 3l4-(0 c6 11.5 PLAFT' 1 QUANTUM 1511 THIRD AVENUE SUITE 323 SEATTLE, WA 98101 TEL 206.957.3900 FAX 206.957.3901 www.quantumce.com TEL e client `No CONSULTING ENGINEERS 16 0(+ Uf -I PT 1 (0 7F+ l IZ) L (t.c1~ vot Z X (o r t Ito S •28 2s ,I 12,(b2- Ib 2L (SW z2_41 (to [I40h I X0 2.40 125 ►�SZ� H��2 CL 13 Po 2T Ca LES project f b Att,„„,= 615(93 "l.)(1 4 87°IA- ti F wi.id p_ CFI Roof �h.t,6 4 fallow 24o( 93)(1 4) 312I1' Rv t(Jf -(Qs q /4-foe 3148 og date project no. S. T L� designer sheet checked by L> "TAR 1 sK) VJALA.- Out -o PLpt.1e 1 In 1 1 1 1 R I R SjAl( 1 1 1 1 1 1 lolo 1 1 1 1 1 1 -x.. f.,,-eA 30 iL I 2 Z I ZDr.) G `T 2a 8 C 1519 193 Aex1 Qr pv,k 1 23 05 3ti-) SF USE- 14 I WI ND 20• E 5 11 2 z I o I -f-t 123 15`1 I°I 't q sF sas c- Z x wnt 1 M1� @21 0c e 4 c 1 E SA QUANTUM 1511 THIRD AVENUE SUITE 323 SEATTLE, WA 98101 TEL 206.957.3900 FAX 206.957.3901 www.quantumce.com 4.3 Esc r L4) OA 6.0vt,: P 4 CDC I W 0 4( V 1)( 11° 25�t' 1 4 asp 1 q- R�,h 2 400 L /4-= 22, At a1c.. �°0 1 v—„ 7 2'i3C> .0.- a- 2 1 1 71 2 31 2 1 (41 --(al` 1 FT A U olas15 A.'\cLwy 4 -ti 1 d jo b 1"7 V LITZ° a 1 35t 4 a.L.,) LIT 20 (I nu.,) CONSULTING ENGINEERS TE1.,os client checked by R?,, 11 1 4(0$ SGJ3 P612-r At. g 8148 0) project date project no. ST L 7 designer sheet (9/9/2008) Linda Pangrle Sound Community Bank From. To Date Subject: CC Hi Linda, Ty Kelly <ty@teleosdesign.com> <Ipangrle @cityofpa. us> 9/9/2008 2.50 PM Sound Community Bank Aaron Kang- Crosby <aaron @teleosdesign com> Thanks for getting back to me this morning Sorry I missed your call I thought I'd email the questions we had 1) Do we need to have our mechanical system specified at the time of permit submittal? The HVAC in the current bldg. is ruined and we have not yet decided what kind of system we want to replace it with 2) Do you require an electrical /lighting plan? Were hoping to be submitting drawings in about a week or two Thanks! Ty Kelly TELEOS 810 3rd Ave. Suite 324 Seattle WA 98104 (p) 206 940.2145 (f) 206 652 0438 (e) ty@teleosdesign.com www teleosdesign com v Page 1-D Contractor File Changes CITY OF PORT ANGELES 'Si1gGAHD'PUSUC SECt H1Fr ON 'X Exit Cancel. Zip code mai. Contractor File Changes Contractor number Name: Address line 1. Address line 2: Address line 3: Zip code: Phone: Contractor type: Description STATE LICENSE BOND LIABILITY INSURANCE 588 GOLDEN HOC ;f €Ea INC 13207 PATTEN AVE 1 198312 BREMERTON 1 360 1 7824829 IGEN GENERAL Contractor Requirements' Document Number 1GOLDEHS942DH WA Status: Active Expiration Date R 103/08/2010 R 1 11 MW A424( 150 DEC -2 -2008 04 31P FROM TELEOS o o 1` 005 0116 o10 0 2,5 TO• COMPANY DATE. FROM. COMMENTS. L'N D4. 144,14: 15 114'4 PE2.0111- 61-611Z 5 2066520438 TO 13604174711 P 1 13 51 H sa 10f t, s 3L- FAX COVER SHEET PAGES Crr Pori 19N G(L(S H (1t,oS Dr 6t, J /OP 1 5DI.l1JD As, 1 rf ‘qrr 4' ----- -.---, PREPARED 12/03/08, 8,59,32 INSPECTION TICKET PAGE 3 CITY OF PORT ANGELES INSPECTOR, JAMES LIERLY DATE 12/03/08 ------------------------------------------------------------------------------------------------ ADDRESS : 110 N ALDER ST SUBDIV, TENANT, NBR, SOUND COMMUNITY BANK CONTRACTOR GOLDEN HOME SERVICES INC PHONE (360) 782-4829 OWNER , GALE P QUINN PHONE (360) 675-5859 PARCEL , 06-30-00-5-6-0125-0000- APPL NUMBER, 08-00000814 DEMOLITION ------------------------------------------------------------------------------------------------ PERMIT: DEMO 00 DEMOLITION REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ---------------------~------------------------------------------------------------------- BL99 01 12/03/08 L BLDG FINAL December 3, 2008 8,25:11 AM 1pangr1e. TY 206-940-2145 BLDG FINAL - DEMO OF THE OLD BURGER KING BUILDING -------------------------------------- COMMENTS AND NOTES -------------------------------------- I . ~ Application Number 08-00001065 Date 8/26/08 Application pin number 324100 Property Address 11 0 N ALDER ST ASSESSOR PARCEL NUMBER, 06-30-00-5-6-0125-0000- Application type description ELECTRICAL ONLY Subdivision Name Property Use Property Zoning COMMERCIAL ARTERIAL Application valuation 0 ---------------------------------------------------------------------------- Application desc TEMP SVC ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ SOUND COMMUNITY BANK JARMUTH ELECTRIC 110 N ALDER ST. PO BOX 635 SEQUIM PORT ANGELES WA 98362 SEQUIM WA 98382 (360) 683-4104 ---------------------------------------------------------------------------- Permit ELECTRICAL TEMPORARY SERVICE Additional desc JARMUTH/ TEMP SVC. -- Permit pin number 133132 - Permit Fee 58.00 Plan Check Fee .00 0 Issue Date 8/26/08 Valuation 0 Expiration Date 2/22/09 Qty Unit Charge Per Extension .00 46.0000 ECH EL-TEMP SRV - 0-100 SRV FDR .00 L,' 1. 00 58.0000 ECH EL-TEMP SRV - 101-200 SRV FDR 58.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 58.00 58.00 .00 .00 Plan Check Total .00 .00 .00 .00 ~ Grand Total 58.00 58.00 .00 .00 (\\ rv \j\ I ~ . SPECTION ELECTRICAL '!'YrE DA'!'b: RESULTS: INSPECTOR: ---- DITCH - - SERVICE pO /.?- ? 108 ~ --- . ... - .~- OUGH - IN FINAL ~7/ofS pp W - . OMMENTS: -, . --- ,- Of9~..v,. CITY OF PORT ANGELES u~ DEPARTMENT OF COMMUNITY DEVELOPMENT - BUILDING DIVISION ~ -=-:0' 32] EAST 5TH STREET, PORT ANGELES, WA 98362 ~~ Application Number 08-00000814 Date 8/05/08 Application pin number 168412 Property Address 11 0 N ALDER ST ASSESSOR PARCEL NUMBER: 06-30-00-5-6-0125-0000- Tenant nbr, name SOUND COMMUNITY BANK Application type description DEMOLITION Subdivision Name Property Use Property Zoning . COMMERCIAL ARTERIAL Application valuation 100000 ---------------------------------------------------------------------------~ Applicat'on desc ' - - - - - - ~~ - DEMD _ D: _:'.": _ ~~~ _ ~~:: _ ~~~ _ _ _ _ _ _~_ ~:2- -t:-: -(JJrrf\~ A~ . ~~~~~ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ ~~~=~~~=~~ _ _ _ _ _ _ _ _ _ '" \e-f".\- ~~ GALE P QUINN GOLDEN HOME SERVICE~ - ~~; ~ 560 SE MIDWAY BLVD 3207 PATTEN AVE OAK HARBOR WA 982775018 BREMERTON WA 98312 (360) 675-5859 (360) 782-4829 - -- Structure Information 000 000 DEMO INTERIOR OF OLD BURGER KING - -- ---------------------------------------------------------------------------- Permit DEMOLITION Additional desc DEMO I.~:OR OF BURGER KING Permit pin number 129759 Permit Fee 50.00 Plan Check Fee .00 Issue Date 8/05/08 Valuation 0 Expiration Date 2/01/09 Qty Uni t Charge Per Extension BASE FEE 50.00 ---------------------------------------------------------------------------- Special Notes and Comments The Fire Department has reviewed the project application and has no comments July 24, 2008 5:26:44 PM sroberds. Site is required to be brought up from nuisance standard during demolition and beyond. July 21, 2008 3:19:09 PM tdahlqui. Underground service with meter and CT cabinet should be located on exterior of north wall. Submit load calculations with Electrical Permit application. Any future construction activities will require improvements to driveways, sidewalks and ADA access to meet current standards along Public Right of Ways. ---------------------------------------------------------------------------- Other Fees STATE SURCHARGE 4.50 /;;: ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due f '7v ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 50.00 50.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 4.50 4.50 .00 .00 ~~ Grand Total 54.50 54.50 .00 .00 "qp Separate Permits are required for electrical work, SEPA, Shoreline, ESA, utilities, private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned for a period of 180 days after the work has commenced, or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of C7;/':"Z~ L~ hrc-tf ~ ~ Date , Print Name Signature of Contractor or Authorized Agent Signature of Owner (if owner is builder) T:FormslBuilding Divisionlfluilding Permit (05113108).wpd BUILDING PERMIT INSPECTION RECORD ~ CALL 4] 7-4815 FOR BUILDING INSPECTIONS. CALL 417-4735 FOR ELECTRICAL INSPECT]ONS. 0 CALL 4] 7-4807 FOR PUBLIC WORKS UTILITIES. CALL 4] 7-4886 FOR BACKFLOW PREVENT]ON ]NSPECTIONS. ~ PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLA WFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE \ INSPECTED AND ACCEPTED. POST PERMIT IN A CONSPICUOUS LOCATION. ~ KEEP PERMIT AND APPROVED PLANS AT THE JOB SITE. - INSPECTION TYPE I DATE I ACCEPTED COMMENTS ....c. YES I NO FOUNDATION: I FOOTINGS I SHEAR WALLS / WALLS I FOUNDATION DRAINAGE / DOWN SPOUTS I I PIERS I I I I POST HOLES (POLE BLOGS.) I I I I PLUMBING I I UNDER FLOOR / SLAB I ROUGH-IN I I WATER LINE (METER TO BLDG) I GAS LINE I FINAL DATE ACCEPTED BY: I BACK FLOW / WATER I I I I AIR SEAL WALLS I I I CEILING FRAMING JOISTS / GIRDERS - I - SHEAR W ALL/HOLD DOWNS 0 WALLS / ROOF / CEILING DRYWALL (INTERIOR BRACED PANEL ONL Y) Z T.BAR I ~ INSULATION I . I I )> SLAB I WALL / FLOOR / CEILING I - I MECHANICAL ~ I HEAT PUMP/FURNACE/DUCTS GAS LINE WOOD STOVE / PELLET / CHIMNEY FINAL DATE ACCEPTED BY: COMMERCIAL HOOD / DUCTS I MANUFACTURED HOMES I I FOOTING / SLAB I I I SLOCKING & HOLD DOWNS I I I SKIRTING I I I PLANNING DEPT. SEPARATE PERMIT 11'5 SEPA: PARKING/LIGHTING I ~ I ESA: I LANDSCAPING I I SHORELINE: I FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCYfUSE I RESIDENTIAL DATE I YES NO COMMERCIAL DATE ACCEPTED YES NO \/ I ELECTRICAL - LIGHT DEPT. 417-4735 I ELECTRICAL ~ LIGHT DEPT CONSTRUCTION R.W. / PW/ CONSTRUCTION - R.W. D ENGINEERING 4 J 7-4807 PW / ENGINEERING FIRE 417-4653 FIRE DEPT. PLANNING DEPT. 417-4750 PLANNING DEPT. I BUILDING 417-4815 BUILDING f2--3-(}f(1 :J~ ~ ~ ~.. If'" :1.1:__ T"'\:..:.=.../n. :1.J:_.. n~p_~:' (f\I:./I'lIf'\O\......A , , pORT,ANGELES ~."", ~ .~ WAS H I N G TON, U. S. A. w~f1- 0 s- 24- ~-a4 '~ Public Works & Utilities Department , ') t '; <q : ~"-..j,lil.a. ~ . ~ ,.-roo:;.;, "' ~ 'i!\, . July 21, 2008 ~ .. -Ii' ..... ~...; " , Sound Community Bank ~ 2005 5th Ave, 2nd Floor Seattle, W A 98121 ! RE: Port Angeles Landfill / Transfer Waste Disposal Application, WDA 08-24; Interior building demolition lION Alder Street, Port Angeles Dear Mr. Floyd: We have received your application for disposal of building demolition debris from the referenced site. Due to the age of the structure and the building materials proposed to be removed from the interior/exterior of the site it appears ti!e debris i~ acceptable for disposal at the P A landfiJI tra!1sfer sta.tion. A copy of your approved application is attached. This approved application .. must be shown to the transfer station scale attendant at the time of disposaL .' . Please be advised that this disposal application is only for the materials and quantities listed in the application. Materials not listed or in. excess of the quantities noted may require separate . . . " applications and approval. Please call if you have questions. - Sincerely ~~p~i~ City Engineer Ene!.: WDA 08-24 Copy: Claudia Stromski . N:\PWKS\ENGINEER\WDAPPLlC 08-24 File: Landfill Solid Waste Disposal Al'plieation~ Phone: 360-417-4805 / Fax: 360-417-4542 Website: www.cityofpa,us / Email: publicworks@cityofpa.us 321 East Fifth Street - P,O, Box 1150 / Port Angeles, WA 98362-0217 .. ... ~ 'I ,..." "" V..... VI j v J.J V,",'..I '"' ....... --- - -. - -. ... -- . _ _ _ _ _ _ 4_ - -- ~ I . IPDA- 08-Z1 PORT ft..Nli,fi;LES LANDFILL WAsTE DISPOSAL APPLICATION To: City of Port Angeles, City Engineer Phone: (360) 417-4803 321 E Fifth Street FAX: (360) 417-4709 P.O. 80x 1150 Port Angeles, Washington 98362 NOTE: All questions must be anS'NeN!d for waste to be approved. 1. Generator Information: Compa.ny Name: SOUAJcD. Cu~tttILC) ;~'1 B,.,I:: MaIling Address: ~dO~ S'" N~; ~1J~aJ,fJ fROth' - SA~ _ t..JA. Q'l124 Contact: QW'{ Fif)~cP, t="'Ac.iH.fl-QS U4~Ittj"" Phone: :tD6 - ~'7~ - lf7Gl ~roiect Name: 1>0.4 flw,Jfi Bt'~ . . Project Location: " 0 Al. ,q,JGy. POy+ A..".14s wA- 'S'~'-l I rOl2-h\~ _&AY'4-e'V kl'~fa.hr~-t__ - 2. Other Contacts (if applicable): - Consulting Firm: . P I e.,lS COntact: _ 7'[ 1<~lIu Phone: ~06 -_'''1-0 - :1,(.,.-;_._ Contractor Name: . ~Q'J f0rWJ.. SAv..". (.QS -.- \ Conlact: ~ LIt~",- ---'='f<k - . ~ Phone: ~-'78~-qg:z, Laboratory: _ tps (,79 7o;J., "1 ) . Contact: cl'l1A2:-----_________ .. . - _. ~. LANd 'F, TC/-! (OJ. EAR-n-lL I tJl<. , tJ ~:r Phone: city of Port Angeles - Landfill Waste Disposal Application Page - '1 . , , . - - ------- - 3. Source of Waste: Check the appropriate box below and briefly describe the project, process, and/or cleanup that will or has producad the waste requiring disposal.. Include the gasoline service station number Of applicable). CERCLAll'vlTCA Remediation Agency Contact: Independent Reme~iaj Action UST ~emoval Unused Chemical Product Spill / Other Source: /4 I / I \ .- ..-- - I \ - --- 4. Waste Material Composition: (check all that apply and include percent of total) r I Soil % Foundry Slag % :,// Concrete/Asphalt S % Dredge Sediments % Preserved Wood % ~1fri/~1 ~r~ Coal Ash % - Wood Ash % % % NOTE: Total must eguaI100%. ~-'."!'!"., 5~V'Vaste Materia.l Contaminants: (check all thiPPIy) Gasoline Meta!s Diesel Solvents PCBs ~ Unused Motor Oil .~ 'sed Motor Oil/\^/aste Oil _. Other ther Petroleum Product - - . .. Unknown NOTE: Supply any MSDS information vlith applicafion, if available, City of Port Angeles ~ landfill Waste Disposal Application Page - 2 ) , . J J ., ----.~ I 6. Estimated Quantity of Waste for Disposai: "SO Cubic yards / 6() Tons (estimate both) I --- Drums I Tons (estimate both) Other NOTE~ Estimaled quantify for disposal must be within 20% of tha quantity actually disPOSed_j (10% for projects over 7,500 tons or 5,000 cubic yards.) f7. Frequency of Disposal: - )( Onetime Monthiy Annual Other A-S ~H'>tZl\ I 18. Waste Sampling: I ' Proper characterization of the waste for disposal requires the collection of representative samples. The methods and equipment necessary for obtaining representative sampies of a waste, and ihe frequency of sampling, will var'1 with the type and farm of the waste. Check the appropriate box and briefly describe how and where the waste was sampled. Include srte maps with sampling locations if possible. Number of COMPOSITE samples Imber of discrete samples per compDsile Number or DISCRETE samples - tj I (~ I r- n__ I I . -.---- -_._._._~ NOTE 1: Unless prior approval has been granted by Port Angeles,. the following sampling frequency wHl be used: 0-25 cubic yards :::: 1 composite sample 25 - 100 cubic yards - 3 composite samples 101 - 500 cubic yards ;;; 5 composite samples 50'1 - 1000 cubic yar~s = 7 composite samples 1001 - 2000 cubic yards = 10 composite samples - - - >2DDO cubic yaids ;;; 10 plus one sample for each addltionai 500 cubIC yards NOTE 2: One composite sample shaH contain a minimum of threeimaxirnum afrive discrete samples, Cit-j of Port Angeles - Landfilf Waste Disposal Applicatfon Pag e - 3 --------- . , \ , - I 9.Waste Analysis: The "Dangerolls Waste Regulations" (WAC 173-303) shall be utilized to determine the appropriate analytical requirements for I..\faste characterization. Ecology publication #91-30 (Revised Apri/1994) "Guidan<?6 for Remediation of Pe~roJeum Contaminated Soils" shall also be used to characterize petroleum contaminated soils from UST releases, Submit alllabOrpfory analytical results, OA/QC data, and Chain of Custody sheets along with this application. (NOTE: The laboratory must be accredited by the Washington State Department-of Ecology.) a) List all analytical test methods used: b) Provide a narrative as to why _.._n. "~~ , - NOTE; Additional sheets attached: YES NO --- 10.- Soli Classifioation: ("FOR PETROLEUM CONT AMINATED SOILS ONLY"") I Based on the analytical dala and ECOI09Y;Jca on #91-30, the soil classification is: (check one) 11 Class 1 Class 2 lass 3 Class 4 Calculated Hazard lndex - 1~ Dangerous Waste Affidavit: I Based on a review of the analytical test results, sIte history, and the applicable regulations, this waste is classified as: (ch~ck one) ''I. Neither Dangerous Waste (DW) nor Extremely Hazardous Waste (EH'vV) . - -" .. Dangerous Waste (DVV) and Waste Code: . . ~ Extremi;:/y Hazardous Waste (EHW) and Waste Code: City of Port Angele.s . Landfill W..ste Disposal ApplicatIon Page - 4 JUN/lU!LUU~/ JU~ Uj:~j rM vcr I ur L,UiYnYJ VC v r f.A 1'11), JOU't J l't! II r, UUO . . I . -- - - 12. Certification: I We, THE UNDERSIGNED, certifY that this application is true to the best of our knowledge_ Alii information provided is correct and the enclosed analytical results represent the proposed w~ste material to the best of our abilities. ' ~ ~. .- -- ..-- Waste Generator Signature _k(!)t./Jf"";J 1b/J1~ <..5';//2. VIcE .7J.,JC tMC:L. ;;7<:::./1 Ptinted Name I Company ~LrDh') fk,(l-tL S,l;2. (./l~~-Sr .!l:U c. 7 /; ~&' Date - ,.---.-. , --. '. ..--.... J ~ ?Of1t {ZQ-1u t( 7ft} lOB:> .. ~tcb-- - - - - 'ICJ/U /08, . . .. a/l//U---fJ-d e Ipl f2~ Vt:Lf:L N:IPO~lCY _P\1000_ SIM 100!C01.WPD City of Port Angeles - Landfifl Waste DIsposal Application -- Page - 5 r BUILDING PERMIT APPLICA TION Print in ink CITY OF PORT ANGELES For City Use Only: Attn: Building Permit Technician ~~7 Date Received ]- Cf......og 321 E. Fifth St., Port Angeles, WA 9836 , ~ ~~60) rtoil>>, ~/~lJHfU~ Permit #----0.[- ~14 \.. \a~ Approve ~ Applicant or Agent ~~J e:,1H.&.t4l;~ ~~ Phone -S"O -~Sj ..S5"6~ Property Owner ?!Tt Awtl &~ ~~AJ Phone ~ ..,-'l~ - S"~ 'SL Property Owner's Address 1~.2L&.{ 7"" A e {),.tllNb~ wA- 9'i:l?1 Contractor/Engineer LAAJ~ ~,fCl, (/.AnU?- f1~) Phone 3&>b - 78.2 - Y-H2.' Contractor/Engineer's Address 3f 6'7 PA~ A.J4. St~~. WA ~ 1. License # .GOL i:) E P. ''1- 1 1) Expires 3- -201b I"ctooL.Dil.0 !-L-,fl1 S~I(J:S.~ I I PROJECT ADDRESS \ \ D N. AL,o~(L (/o(l."t 4N Gtt L(5 WA. cH'1(,2 , J Parcel Number Lot Zoninq proi1f Tv~e & Brief DescriDtion: 0 Residential ~ Commercial 0 Multi-family 0 Industrial heck a I that apply o New Construction t erN H.1\N ~ VAc,AN\ "~LA~b((0 \GIN 6'1 ~lA\L,()lrJG INTo A rsA,J~ e~/h)(iH o Addition (-010 I' SolAf'lO C,(l""'t\-I\A~liJ GANK..... APPLJJI\~ ~f;!: IN-rff-I.O~ ~ P~rtYnI"T: o Remodel o Repair G,l,\,iIN!;' fXISTIN6. INI~~\O~..... AND fOS~I()L~~\lOtJ5 o~ f.o<.;.F. oRe-roof --4rt.f c..c..~$ ':t.'~ ~. IV ..u......./lI.> 'I-. Demolition o Heat System o Heat pump 0 wood-burning s ove 0 gas fireplace 0 pellet stove 0 other o Other ~~L.aier ~ ~edde.&., -try d(') CL CI"> f'h..D te...--+r:-, ri P.,'wH"), CornO leie-J. 12-3 - 0& v I Floor Areas Existina (SQ. ft.) ProDosed (SQ. ft.) . , Basement @$ per sq. ft. = $ 1 sl Floor ~IS'O l\lotJ(. ADO{D 2nd Floor I 3rd Floor Garage .if Carport V-'ASTt. ~ Aft? Covered Porch ..A~o~, "'~ W ,.J21. Deck Shed I~E,JIA E Other TOTAL VALUATION $ IDOl/) DO,(),) Total footprint of structures I) ~5"O sq, ft. + Lot size L{fo 045 sq. ft. = Lot coverage 1.'21 % J I Max. height of proposed structures Al/I# ft. Occupancy group # of bedrooms 0 Will a lawn sprinkler system be installed? --.IJg Occupant load # of full baths 0 Will a fire sprinkler system be installed? ~ Construction type # of half baths .::I I have read and completed this application and know it to be true and correct. I am authorized to apply for this permit and understand that ft is my responsibility to detennine what pennits are required, and to obtain pennit~ ~ working on projects. DaleJ/jJ IJ Y Print Name r:~. t=loy,j Signalure----tZ:z W. /) T:Forms/Building Division/Bldg Permit Appl.-2006 Co e.doc ;1,.q./'4~ ~~~ Slc.auO ~"'IW~ 'BN/.: ----- ,. (;f (/ ...... l! (; .... t , ...... ..... , I , . I , , , , , , , , , t , , , , , , , , , , , . , , \ , , /i , , , , , , , , , , ...... , , ... , ....., , , , , , , , "'.. " '... , ...... , ...... , , t \ t . , Street Lookup Page 1 of 1 I Parcel Number 0630005601250000 . Site Address: 110 N ALDER ST PA I Quit I Taxpayer: BANK OF AMERICA CORP. REAL ESTATE ASSESS NC1-001-03-81 101 N TRYON ST CHARLOTTE, NC 28255 Title Owner: QUINN GALE P 560 SE MIDWAY BLVD OAK HARBOR, WA 98277-5018 Description: CARTER'S, THOMAS W SUBDIVISION L T16-17&PT18 SUR V10P140 BL 132 SURVEY V41 P65 Value Summary: Note: Listed values do not reflect adjustments made for exemption programs such as Senior/Disabled or Current Use programs (except Commercial Forestland properties). Land Value: 444,320 Improvements Value: 154,200 Total Assessed Value: 598,520 Property Characteristics: Note: Use Code is for Assessor's purposes only. Contact the appropriate planning or building departments for Zoning and allowable usage of property.. Use Code: 5805 FAST FOODS Land Size (acreage): .00 Note: Acreage is not listed for all properties in the Assessor's records. More information about land size. Tax Status: Taxable Tax Code Area:: 0010 Note: Zoning and zoning codes change constantly. Verify all zoning with the appropriate planning or building department. Building Characteristics: (Click on Bldg. # for more details.) .JL Blda. TVDe Blda. Stvle Total S.F. BD BA 01 One Story 3286 Tax History Sales History Other parcels at this address: I Quit I 'v~ r;n http://apps,clallam,netlwebsite/sitis_s,pgm?address=lIO &street=ALDER ST &pu.,. 7/9/2008 ----- -- PORT ANGELES LEASE 1. PARTIES: This Lease, dated for reference purposes only, July 1,2008, is made by and bet\.veen Gale Pat Quinn and Betty L. Quinn, husband and wife, and l.yndell S. (Quirm) Collins, daughter, herein collectively called "LANDLORD" and SOUND COMMUNITY BANK, a corporation incorporated under the laws of the United States, herein called "TEN ANT' , 2. PREMISES: Landlord does hereby lease to Tenant and Tenant hereby leases fOffi1 Landlord the real property and improvements thereon legally described as follows: Lot 4, except the westerly 5 feet and all of lots, 1,2,3, 16, and 17, Block 132 of Thomas W, Carter's Subdivision of Suburban Lots 11 and 12, Port AngelesTown site as per plat thereofrecorded in page 19, records of Clallam County, Washington. 3, TERM: The basic lease term shall be twenty (20) years, plus the partial month, if any, in which the term commences a hereinafter provided, however, that anything to the contrary herein not withstanding, Tenant shall have option to extend the tenn of this lease for two (2) successive periods of five year each, the first of which shall commence as of the expiration of the initial tem1 hereof. In order to exercise each option, Tenant must notify Landlord of its intent to do so not later than nine (9) months prior to the expiration of the initial term hereof, or the then existing extension period as the case may be, Tenant shall have the right to exercise an option only as long as Tenant is not in default of and of the telms, conditions or payments required hereunder. 4. COMMENCEMENT: The lease term shall commence October I, 2008 or sooner, at Tenant's option; provided, however, that anything herein to the contrary notwithstanding, the lease term shall not commence on the date above described unless and until each and everyone of the following conditions have been satisfied; I a. f\.'Iemorandums of Lease embodying the terms of this lease and satisfactory in form and substance to Tenant has been recorded. h Tenant has received from each mongagec, trustee or similar party having u. an encumbrance against the Premises a non-disturbance agreement in recordable form satisfactory in form and substance to Tenant. 5. RENT: Tenant agrees to pay Landlord a minimum rent without notice or demand as follows: a. Month One and Two: No rent due. b. Months Three to Twenty-four: Five Thousand Dollars ($5,000) per month. c. Years Three through Five: Five Thousand Five Hundred Dollars ($5,500) per month. d, Years Six through Ten: Rent shall be increased in accordance with changes in the Consumer Price Index for years three through five or to Six Thousand DoHars ($6,000) per month, whichever is less. e. Years Eleven through Fifteen: Rent shall be increase,d in accord~ ~~ with changes in the Consumer Price Index for years ~ through ~ or ':p a- to Six Thousand Six Hundred Dollars ($6,600) per month, whichever is less. ~ f. Years Sixteen through Twenty: Rent shall be increased in accord~tJe b~ . with changes in the Consumer Price Index for years~1hrough' TfrV' I? Q to Seven Thousand Two Hundred Sixty Dollars ($7,260) per month, \ whichever is less, g. Years Twenty-one through Thirty: Rent shall be increased in accordance with changes in the Consumer Price Index for years sixteen through twenty, Notwithstanding the foregoing rent for years twenty-one through thirty shall increase no less than 5% every five years, Consumer Price Index means the Consumer Price Index for all Urban Consumers in the Seattle-Tacoma-Bremerton, Washington region as promulgated by the United States Department of Labor. 2 6. ADDITIONAL CHARGES: In addition to the minimum rent provided for in Article 5 herein above and commencing at the same time as minimum rent commences, Tenant shall pay all reai estate taxes on the Premises including land, building and improvements thereupon. Said real estate taxes shall include all real estate taxes and assessments that are levied or assessed against the Premises. Should there presently be in effect, or should there be enacted during the term ofthis lease any law, statute, or ordinance levying any tax (other than federal or state income taxes) upon rents, Tenant shall pay any such tax or shall reimburse landlord on demand for any such taxes paid by landlord. 7. PROHIBITED USES: Tenant shall not allow the Premises to be used for any improper, immoral, unlawful or objectionable purposes, nor shall Tenant cause, maintain or permit any nuisance in or about the Premises, 8, COMPLIANCE WITH LAW: Tenant shall not use the Premises or permit anything to be done in or about the Premises which will in any way conflict with any law, statute, ordinance, or govemmental rule or regulation now in force or 'which may hereinafter be enacted. 9. IMPROVEMENTS TO BE LOCATED ON GROUND AREA: Tenant agrees to remodel and improve the existing building located on the Premises, Tenant shall cause to be prepared plans and specifications for construction of the improvements. Any and all construction costs shall be borne solely by the Tenant. 10. J,-IENS: Tenant shall keep the Premises free from any liens arising out of any work performed, materials furnished or obligations incurred by Tenant. ..., _I lI. ASSIG~MENT AND SUBLETTfNG: Tenant shall not assign, transfer, mortgage, pledge, hypothecate or encumber this lease or any interest therein, and shall not sublet the Premises or any pan thereof \.vithollt the \.vritten consent of the Landlord, which consent shall not unreasonably be withheld. Consent to one assignment, subletting, occupation 01" use by any other person shall not be deemed to be consent to any subsequent assignment. 12. HOLD HARMLESS: Tenant shall indemnify and hold harmless Landlord against and from any and all claims arising from Tenant's use of the Premises or from the conduct of its business or from any activity, work or other things done, permitted or suffered by the Tenant in or about the Premises and shall further indemnify and hold hamlless Landlord against and from any and all claims arising from any breach or default in the performance of any obligation on the Tenant's part to be performed under the terms of this lease, or arising from any act or negligence of Ten ant , Tenant as a material part of the consideration to Landlord, hereby assumes all risk of damages to property or to persons in, upon of about the premises. 13. LIABILITY INSURANCE: Tenant shall at its O,^,TI expense obtain and keep in force during the term of this lease a policy of comprehension public liabiiity insurance insuring Landlord and Tenant against any liability arising out of the ownership, use, occupancy or maintenance of the Premises and all areas pertinent thereto. Such insurance shall be in an amount not less than $2,000,000 for injury or death of one or more persons in anyone accident or occurrence with self-retention of $1 ,000,000. Such insurance shall further insure Landlord and Tenant against liability for damage to property of others in an amount of at least $2,000,000 with self-retention of $1 ,000,000. The limit of such insurance shall not, however, limit the liability of the Tenant hereunder. Tenant may provide this insurance under a blanket policy provided that said insurance shall have the Landlord's protective liability endorsement attached thereto, CASUAL TY INSURANCE: Tenant, at Tenant's expense, shall keep the buildings and improvements on the Premises insured for the mutual benefit of Landlord and Tenant during the telm of this Lease and any extensions thereof against loss or damage by fire and other casualty in an amount sufficient to prevent Landlord or Tenant from 4 ; -. -- -------------- becoming a co-insurer of any loss, but in the amount at all times equal to not less than 100% of the then full insurable value of the improvements situated upon the Premises. Fuli insurable value means the actual replacement value. 14. UTILITIES: Tenant shall pay tor all \-vater, gas, heat, light, power, drainage, garbage, sewer charges, telephone service and all of the services and utilities supplied to the Premises together with taxes thereon, 15, PERSONAL PROPERTY TAXES: Tenant shall payor cause to be paid before delinquency any and all taxes levied or assessed and which become payable during the teml hereof upon all Tenant's leasehold improvements, equipment, furniture, fixtures and any other personal property located in the Premises. 16. HOLDING OVER: lfthe Tenant remains in possession of the Premises or any part thereof after the expiration of the term hereof, such occupancy shall be a tenancy from month-to-month at a monthly rent in the amount equal to of the 1/12th the last annual minimum rent plus all other charges payable hereunder and upon all terms hereof applicable to a month-to- month tenancy. 17. TENANT'S DEFAULT: The occurrence of anyone or more of the following shall constitute failure and breach by Tenant: a. Failure by Tenant to make any payment of rent or any other payment req uired hereunder for a period of twenty (20) days after written notice thereof by Landlord. b. The failure by Tenant to observe, perform any of the covenants or conditions of this lease other than those described above, where such fnilure shall continue for a period of thirty (30) days after \vritten notice thereof by Landlord provided that the nature of the default is such that more than thiliy (30) cl:tys are re8sonably j ------- required for its cure, Tenant shall not be deemed in default. Tenane promises [0 diligenely pursue the cure until completion. In the event of any sllch default or breach by Tenant, Landlord may at any time thereafter terminate Tenant's right to possession by any lavvful means in which case this lease shall terminate the Tenant shali immediately surrender possession of the Premises to the Landlord. Landlord may, in addition to tenninating this lease, pursue any other remedy now or hereafter available to Landlord under the laws or judicial decisions of the State of Washington. 18. LANDLORD'S DEFAULT: The failure by a Landlord to observe or perform any of the covenants or conditions of this lease \vhere such failure shall continue for a period of thirty (30) days after written notice from Tenant, provided, however, if the nature of the Landlord's default is such that more than thirty (30) days are reasonably required for its cure, then Landlord shall not be deemed to be in default. Landlord promises to diligently pursue the cure until completion; provided, however, that if Landlord is unable to cure such default for a period of thirty (30) DA YS, Tenant shall have the option to terminate this lease. In the event of any default or breach by Landlord, Tenant may, in addition to terminating this lease and pursue any other remedy nOv\7 or hereafter available to Tenant under the laws or judicial decisions of the State of Washington. 19. RECONSTRUCTION: In the event fire or any other casualty damages the Premises, during the first fifteen (15) years of this lease, any and all reconstruction shall be at the sole cost and expense of Tenant. In the evenlthe Premises are destroyed after the 15th year of the basic term of this lease, reconstruction shall be at Tenant's option. , 20. EMINENT DOMAIN: Ifany public authority shall take the whole of the Premises hereby leased under the power of eminent domain,then the term of this lease shall 6 cease as of the date possession and the rent shall be paid up to that date. All compensation for the total taking, whether fixes by agreement or judicial a-vvard: shall be divided between the Landlord and Tenant as follows: a. For the Tenant: All amounts attributable to the Tenant's improvements less the residual value thereof at the end of the period of the lease assuming that the Tenant has exercised all options for the extension of the lease. b, For the Landlord: The balance ofthe award, If only a part of the leased Premises shall be taken under eminent domain and the remainder of the leased Premises not so taken can be made tenable in the Tenant's opinion for the purpose for which the Tenant has been using the Premises, then this lease shall continue in full force and effect as to the remainder of said Premises, and the terms herein provided shall continue in effect except that the rent shall be reduced in proportion to the amount of the Premises taken. If any portion of the Tenant's improvements is taken, the Tenant shall be awarded such amount as is fixed by the court for damage to the improvements and to the Landlord such amount as the COUli shall award for the taking of the portion of the fee of the Premises so taken. However, if only land is taken, all damages awarded shall be the Landlord's for the value of the fee afthe Premises, In any event, either by partial taking or total taking any and all compensation for the interruption of or loss of business by the Tenant shall be awarded to the Tenant. 21. SURRENDER OF PREMISES: Upon the termination of this lease, Tenant shall surrender the Premises and the improvements; provided, however, that the Tenant shall be required to remove any and all trade fixtures, personal property, refuse, garbage, debris, signs and other than Tenant's right to remove aforesaid i terns, all 0 f the Tenant's right, title and 7 interest in and to the Premises and improvements shall then cease. Tenant shall repair any and all damages to the Premises caused by said removal and make all necessary improv'ements up to city of POt't Angeks and/or Washington state, code standard, and Landlord may require inspection approval. Landlord may waive the duty to remove and repair as above pro-vide by waiver in writing as requested by Tenant thirty (30) days prior to the expiration of the term at the Landlord's option. In the event the tenant does not rebuild the existing building at the time of surrender the existing building will be removed and the propeliy will be in readiness to begin new construction. If the existing building is rebuilt or a new building is placed on the property this condition does not apply, 22, SIGNS: The Tenant shall not erect or install any signs, advertising media, window or door lettering contrary to the City of Port Angeles codes. '1' FIRST RIGHT OF REFUSAL TO PURCHASE PREMISES: If Landlord .t.-.) . decides to sell the Premises, Landlord shall offer to Tenant the right to purchase the Premises subject to this lease. The notice shall set forth the price at which Landlord will sell the premises, which shall be the fair market value of the Premises subject to the lease. If the parties cannot agree upon the fair market value as the purchase price for the Premises for a period of forty-five (45) days following the date of the Landlord's notice sell the premises to Tenant, the parties shall make a good faith effort to establish the fair market value of the Premises through mediation in accordance with the provisions of Rule 39,1 of the Local Rules of the United States District Court for the Western District of Washington, If the parties are unable to establish a purchase price through mediation, the purchase price shall be established by arbitration, All expenses of r:- ." I" , , I 8 , , ,. mediation and/or arbitration shall be borne equally by the parties, except each party 'vvill be responsible for its expenses and the expenses of its representatives participating in the mediation and/or arbitration and the fees and expenses of aItorneys, accountants. appraisers, or other experts employed by the pany in connection "vith such mediation and/or arbitration. The purchase of the Premises by Tenant shall be closed within one hundred eighty (180) days after the date the option is exercised. At closing, title to the premises shall be conveyed by Landlord to Tenant by statutory warranty deed, is to be free of all encumbrances or defects. Rights reserved in federal patents or state deeds: building or use restrictions general to the area, other than platting and subdivision requirements; utility easements; other easements not inconsistent with Tenant's intended use; and reserved oil and/or mineral rights; shall not be deemed encumbrances or defects. Encumbrances to be discharged by Landlord shall be paid from the purchase money at the date of closing. Landlord shall provide to Tenant at closing a Standard Owner's Policy of Title Insurance, with coverage in an amount not less than the purchase price, insuring Tenant's good, marketable and indefeasible title to the Premises in fee simple absolute, subject only to standard printed exceptions appearing in the title policy fOlm, and nondelinquent general property taxes payable during the year in which the closing date occurs. General real estate taxes and assessment installments due during the year of the closing and rents shall be prorated between Landlord and Tenant as of the Closing Date. Landlord shall pay all real property transfer taxes, recording fees and the premium for the Title Policy. Landlord and Tenant shall each pay one-half (1/2) of the escrow fee. 24. GENERAL PROVISIONS: a. Plats and Riders: Clauses, plats, riders and addendums. If any, affixed to this lease are a part thereof. 9 b. Waiver: The waiver by Landlord of any telm, covenant or condition herein contained shall not be deemed ro be a vvaiver of any such tenn, covenant, or condition or any subsequent breach 0 f the same or any other term, covenant or condition herein contained. c. Marginal Headings: The marginal headings and articles, titles to the articles of this lease are not a part of the lease and shall have no effect upon the construction or interpretation of any part hereof. d, Time: Time is of the essence of this lease and each and all of its provisions which performance is a factor. e. Successors and AssiQ:ns.: The covenants and conditions herein contained, subject to the provisions as to assignment, app19 to and bind their heirs, successors, executors, administrators and assigns of the paIiies hereto. f. Ouiet Possession: Upon Tenant paying the rent reserved hereunder and observing and performing all covenants, conditions and provisions to be observed and performed by Tenants part, Tenant shall have quiet possession of the Premises for the entire term hereof subject to all the provisions in this lease. a Prior Agreements: This lease contains the rent reserved hereunder and "". observing and performing all covenants, conditions and provisions on Tenant's pati to be observed and performed, Tenant shall have quiet possession of the Premises for the entire term hereof subject to all the provisions in this lease. h, Inabilitv to Perform: This lease and the obligation of the Tenant hereunder shall not be affected or impaired because the Landlord is unable to fulfill any of its obligcltiol1s herein below or is delayed in doing so if such inability or delay in caused by !/', i') ------ . reason of strike, labor trouble, acts of God or any other cause beyond the reasonable control of the Landlord in partial invalidity. Any provision of this lease which shall prove to be invalid, void or illegal in no \-vay affects, impairs 0[' invalidates any other provision hereof and such other provisions shall remain in full force and effect. 1. Cumulative Remedies: No remedy or election hereunder shall be deemed exclusive, but shall wherever possible be cumulative with all other remedies at law or in equity. J. Choice of Law: the laws of the State of Washington shall govern this lease. k, Attornev's Fees: In the event of any action or proceeding brought by either party against the other under this lease, theprevailing party shall be entitled to recover for the fees of its attorneys in any such action or proceeding, including cost of appeal if any, in such amount as the court may adjudge reasonable as attorney's fees. 1. Subordination alld AttortLrnent: Upon request of the Landlord, Tenant will in writing, subordinate its rights hereunder to the lien of any mortgage or deed oftrust, and bank, insurance company or any other lending institution omv or hereafter in force against the Premises and to all advances made or hereafter to be made upon the security thereof so long as prior to or contemporaneous with the execution for said subordination agreement, Tenant has received from the lending institution a non-disturbance agreement providing that so long as Tenant duly performs its obligation and is not in default, its possession of the Premises will not be disturbed in the event of a foreclosure, ano further, providing that the non-disturbance agreement is binding upon the successors, heirs, and assigns of said bank, insurance company or institutions. 11 The provision of this article to the contrary not\vithstanding and so long as Tenant is not in default hereunder, this Lease shall remain in full force and effect for the full term hereof. m. Notices: All notices and demands 'vvhich may be required or permitted to be given by either party to the other shall be in writing. All notices and demands by the Landlord to Tenant or Tenant to Landlord shall be sent by United States Mail, postage prepaid, addressed the Tenant/Landlord to the address herein below or to any other place as Tenant/Landlord may from time to time designate, To Landlord at: Pat and Betty Quinn 1781 ih Ave. Oak Harbor, W A 98277 With a copy to: Lyndell Collins 4708 Camano Place Anacortes, W A 98221 To Tenant at: Laura Lee Stewart, President/CEO Sound Community Bank Administrative Office 2005 5th Ave. 2nd Floor Seattle, Wl\ 98121 Mailing Address: PO Box 34155 Seattle, W A 98124 With a copy to: Porter, Kohli & LeMaster, P.S. 1325 4th Avenue, Suite 940 Seattle, W A 98101 25, TENANT'S RIGHT TO CANCEL: (j is unckrstood that Tenant shall have a period of two one-hundred-eighty (nO) day~ from fi nal execution c f chis lease in which to get all 12 r -~- ~ , , the necessary governmental permits and approvals to operate Tenant's proposed business on the subject property. In the event the Tenant is not successful, it may terminate this lease by giving Landlord notice in writing within thirty (30) days prior to commencement ofrent. Dated the clay and year first written above, LANDLORD: ~~~~~1!~ ~-' /oO-/-C!8' ~t. '4'~ /tJ) JOY yndell S. Quinn Collins . Date STATE OF WASHINGTON) rJ;1JtJ!" ) ss, COUNTY OF ) _J I certify that I [mow or have satisfactory evidence that Laura Lee Stewart, President/CEO Sound Community Bank is the person who appeared before me, and she acl<.nowledged that she signed this instrument and acknowledged it to be her free and voluntary act for the uses and purposes mentioned in the instrument. 5t-~ '0.) 1111//////".- Dated this '7'(l ff((1 ~ SAA' ----_ day of. , mt!fJtr' , 20~ ' ,f <<,1(;,.......... AI ~-:.. -, /'i i (I;~/( \ 'v . ""ON" - \\ ...~s'" ~ ". ~ -::. / if tl-/)/' I;VJ!)) ,Il L( I \ ~.~ +..o..-p.... ~ 0':0' ~OTARy ~"'i'- ~ Pri"ed Name: r ell I Ce.t.')",-->-uv.( t,,- I-\L..ACJf ~ 0:0 {I\~.... :;:; _'_ In;m ~ .... . . ~ ......./ ---- .... . Pu C .s Notar~ Public in, ~~d for ~S~aty0t( ~ tf) ". au ... <:"~ ... :A.. "/ ...... 0 \\ Washmgton, reslOmg at t/t.-J . ~ "',>: .... ..29..."\....." \' My appointment ~x'pires: . . . ~.Il1 "':.. t$' ............ ~e:,. " L-/-Zh.- lD ' ~':,o..Pf:' W po, Sl(\~ IlIff .""'"""'~~~oMJIIII STATE OF WASHINGTON) . - COUNTY OF -r:""71~rJ ) ss, ) I certify that I know or have salisfactory evidence that Gale Pal Quinn and Betty L. Quinn, husband and wife, me the persons vvho appeared before me, and they acknowledged that they signed this . ') , , '- ~j ~- t instrument and acknowledged it to be their free and voluntary act for the uses and purposes mentioned in the instrument. Dated this I day 0 f CCt.::::CeL ,2008. ; l / /.";" '//~~./;.,;.". ~n;0 -)-6~ _ _ i,IIIX-.\\E H ".;;- \' ~v~ ....... ~"k ~;- \ .' '. - ,\ ~ ...~sS\ON s-l>' ~ -==:.. Printed Name\fllj ~ au.o~ ,~~ j ~..~ ~...... ~ /! ~o1.AR'r ~"" ~ Notary Public in and for the State or ~ . 0 (jl." s: ......... : ~ Washington, residing at _I&;!5 re m~1.) trlvc.i " . . s ~ ~. PUBI.-\G ; ~ ~ ... ({I '. , .. 0 ~ My appointment expires: )Lp J ) I -:::. ~ .....e~06...l\..... ~ \" , ~)'~ ........... ':(-.~ II - OF Co ,I -- W t-. -~ .". -J""... .fl' ..../. ..../f/l f" STATE OF WASHINGTON) ) ss. COUNTY OF ) I certify that I know or have satisfactory evidence that Lyndell S. Quinn Collins is the person who appeared before me, and she acknowledged that she signed this instrument and acknowledged it to be her free and voluntary act for the uses and purposes mentioned in the instrnment. Dated this day of .,2008. Printed Name: Notary Publ ic in and for the State 0 f Washington, residing at __ ---- ~'Iy appointment expires: - ---- 14 d,~'~1 CITY OF PORT ANGELES ~ "D!I PUBLIC WORKS - ELECTRICAL DIVISION ~I ,21 EAST 5TH STREET. PORT ANGELES. WA 9R,62 - - - ELECTRICAL PERMIT Issued: 9/08/99 Permit No: 6739 OWNER/APPLICANT------------------------PROPERTY LOCATION------------------------ BURGER KING 110 ALDER N 110 N ALDER ST Lot: 17/18 Port Angeles, WA 98362 Block: 132 Long Legal: 360/452-3437 Sub: T. W. CARTER T: S: Parc No: CONTRACTOR-----------------------------DESIGNER--------------------------------- IDEAL ELECTRICAL SERVICES 5013 PACIFIC HWY E. 310 FIFE, WA 98424 , 253/850-1616 000/000-0000 PROJECT INFO------------------------------------------------------------------__ prj Type: COML. MISC. prj Value: $0.00 Occ Type: Cnstr Type: ADD CIRCUITS Occ Grp: Occ Load: Land Use: Electrical Heat Service Type Baseboard KW: 0 Riser Voltage: 0 Furnace KW: 0 Overhead Service Diameter: -1 -3 Heat Pump KW: 0 Underground Service Service Size: o AMPS Fan/Wall KW: 0 Temp Service Feeder Size: o AMPS PROJECT NOTES-----------------------------------------------------______________ NEW LIGHT POLE AT BURGER KING PROJECT FEES ASSESSMENT--------------------------------------------_____________ 'Service: $0.00 Additional Feeders: $0.00 Circuit Wiring: $54.00 , , Temp Service: $0.00 TOTAL FEE: $54.00 ! Misc : $0.00 Amount Paid: $54.00 I ================================= -------------------------- TOTAL FEE: $54.00 Balance Due: $0.00 I , , I COMMENTS/ACTION NEEDED .- ----- - -- - .._.._~~ ELECTRICAL PERMIT INSPECTION RECORD CALL 417-4735 FOR ELECTRICAL INSPECTIONS. PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLA WFUL TO COVER. INSULA TE OR CONCEAL ANY WORK BEFORE IT IS INSPECTED AND ACCEPTED. KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE INSPECTION TYPE I DATE I ACCEPTED COMMENTS YES I NO , r I DITCH 9'///'/?? /lW't I RUUGH-IN I CUVER ,) 1 I SERVICE ~FINAL r , I ,91)I(~q I ~ I I I I i I , I I I GENERAL COMMENTS, PW-II02.IS(4r'96] . : I , I I . .. .s CITY OF PORT ANGELES PUBLIC WORKS - ELECTRICAL DIVISION ~21 EAST 5TH STREET. PORT ANGELES. WA 98~('2 ~r....~ - - - - ELECTRICAL PERMIT Issued: 2/25/98 Permit No: 6236 OWNER/APPLICANT------------------------PROPERTY LOCATION------------------------ BURGER KING 110 ALDER N 110 N ALDER ST Lot: 17/18 Port Angeles, WA 98362 Block: 132 Long Legal: 360/452-3437 Sub: T. W. CARTER T: S: Parc No: CONTRACTOR-----------------------------DESIGNER--------------------------------- ECONOMY ELECTRIC INC. 4842 S. ADAMS TACOMA, WA 98409 , 360/000-0000 000/000-0000 PROJECT INFO-------------------------------------------------------------------- prj Type: COML. MISC. Prj Value: $0.00 Occ Type: Cnstr Type: ADD CIRCUITS Occ Grp: Occ Load: Land Use: Electrical Heat Service Type Baseboard KW: 0 Riser Voltage: 0 Furnace KW: 0 Overhead Service Diameter: -1 -3 Heat Pump KW: 0 X Underground Service Service Size: DAMPS Fan/Wall KW: 0 Temp Service Feeder Size: DAMPS PROJECT NOTES------------------------------------------------------------------- CHANGE EXTERIOR LIGHTING AT BURGER KING I I PROJECT FEES ASSESSMENT--------------------------------------------------------- . Service: $0.00 Additional Feeders: $0.00 Circuit Wiring: $52.00 Temp Service: $0.00 TOTAL FEE: $52.00 Misc : $0.00 Amount Paid: $52.00 ===~============================= -------------------------- TOTAL FEE: $52.00 Balance Due: $0.00 ~.OMMENTS/ACTJON NEEDED .' , ELECTRICAL PERMIT INSPECTION RECORD CALL 417-4735 FOR ELECTRICAL INSPECTIONS. PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLA WFUL TO COVER, INSULA TE OR CONCEAL ANY WORK BEFORE IT IS INS.."", "D AND ACCEPTED. KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE INSPEC110N TYPE I DATE I Al....._....... COMMENTS ns I NO DITCH I KUUUH-lN I CUVhK I SERVICE I I I FINAL 1Z./27/QX'1 ~I I I I I , GENERAL COMMENTS, .PW.II0'2.1'I~ I . , I , \ ! : . i - ---. ----_. -~- ---- ~," I 01'7 '}-. . CITY OF PORT~~NGELES ,. 000400 DEPARTMENT OF L1GH A FEE RECEIPT NUMBER PERMIT NUMBER APPLICATION.AND ELECTRICAL PERMIT '. TOTAL FEE /68 aQ rdfl.ul~&t . l I"A'JI.IA~ CONT. Lie. NO. TIME TO COMPLETE NO. STORIES LEGAL OCCUPANCY ELECTRICAL PERMIT ONLY NO OCCUPANCY OR U~E ESTABL~SHED UNDER THIS PERMIT , , , , 110 .! 1 ~tL {)?(l , Site "Address , CORRECT AO'DAESS IS RESPONSIBILITY OF APPLICANT PERMITS WITH WRONG ADDRESSES ARE CANCELLED Owner WIM-t--. So N jI\.\.,( ~i-eJL.. Installation By m (' 'h~i 1-<'..4)" i2l€.~ . " Owner's Address Po (1;,6 Y:: 'i.3 c..c.c-~ . C;tJl.p", -0'. . , , "2.<':, ~ Id .", ~ru.-r , Installers Address Day Phone .....--r\.. - .~s-- ~J s-,-: Installers Phone $!:>'d~ -7 ~ ;. Application i~her;bY f!lade for ~ermit to in5t~II'Electrical Equi'pment as JOllows: 5..-' ~/i v'fL t<p. L,T/'dJ V'''.kL+- f3i./ fUe.I{., K; IV, c.. ., -~ - r ~ \ , \ GI?ArI 7 rf),.,..-V" cJ -. , , IIS:}..- 7'1 ::n "". wi,i.ng M~thOd ~ .'.\ .24'h09 . , AMP '1 .~ I,': USE'~F.ciAC,UIT., AMP '240V USE OF CIRCUIT NUMBER PEA 120V ~~\ . FEE ~UMBER PEA 120V 100R i FE1, CIRCUITS CIA :t10. CIRCUITS QIA .... \\ 10 30 ":. I LIGHT II S'GN .:2 ..20 v /(00 LIGHT I I SO VOLTS /. OA LESS CONVENIENCE II MOTOA I I CONVENIENCE I I MOTOR I I I I APPLIANCE I I I MOTOR I I I I I DISHWASHER I I . I FIAE AL~AMS I I I I I- DISPOSAL I I II BUAGLAA ALAAM I I I I I ._ RANGE I I I MISC. I I I I I I OVEN I I I I I I I I I WA TEA HEATER I I I I I I I I I LAUNDRY I I I I I I .1 I I DRYER I I I II REINSTALLATION LIGHT FIXTURE # I FURNACE I I I II sge TOTAL FEE '/6B ...~ GAS _ Oil I FURNACE 1 I I I ENERGY FEE ~ ELEOTRIC . II ..4)- 1 I ELECTRIC HEAT I I I I BASIC FEE II TOTAL FEE / I ELECTRIC HEAT I I I. I. I II SIZE OF SERVICE SWITCH OR CIRCUIT BREAKER I A.C. UNIT I I I I I /~ AMP 3~ PHASE I FEEDEA I I I I I /I SIZE OF SERVICE ENTRANC CONDUCTORS I SERVICE lh'co1.4 I ~I~~I ~) fYJr I'M j{J.[ fMJ A.W.G. [ SUB-TOT At. /6-2 I SIZE OF GROUND SIZE OF ENTRANCE SWITCH I certiiy that the work. to be performed under this permit will be done by the Installer and in conformance with the-N~e. OateApplicatlonmado Ej/'-2A 1? <!R_<_ By ~d ~~ I CONTRACTOR OR OWNER (OR AUTHORIZED AGENT) P.ermission is hereby glv€ln to do the above de~cribed work, according to the conditions hereon and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinances.of the C[ty of Port Angrles;." '. \\ -) ~ \ "\ - . DIRECTOR OF CITY LIGHT -.." . . .- /J1r;d.f( J? )~.-:- ~ \ - -,' Date Permit Issued By . -' ~ .. . PLANS APPROPED-'" , , - " I~' {/,. - l".' . \ ~~ ;;"-1-(:> Notify Department of City Light by Street Address and Permit Number when ready for inspection. Work must not be covered or current turned on before inspection and O.K. for covering or service has been given by Inspector in I , Writing on Permit Placard. A. - Permits Phone: 457-0411 Ext. 158. WARNING PERMIT PLACARD MUST BE KEPT POSTED ON THE WORK - SEE OVER _ ~ WHITE. Original CANARY - Duplicate PINK. Triplicate WHITE CARD - Inspector's Report OLYM!!C PRI~!ERS. tNC. , RElPRT OF INSPECTOR. ~ '. , ~ , :.. ~ ~ J ,--I ~5 I DATE OF VISIT MADE BY REMARKS I 20' rf{~M 7({#A/'5. "'-0 f~O(Rll/rC 1'I//lJ'J( . I 11, (~-ys- #2Y o f( (ODe/L!. ON 5L;f-j) I r'~ (J- ~> 4//y oK f <..II..M IT<:'<' 5'6-tV CONP" , r ~^" /l,Tc ~ f 11- )6r g'~ 1f/f O~ h.,.-il.el? ('ON/}!// r ('<9 v~;e I I ------ ------ . :5 Pee s rrr;"II" ;).,). COG AI ~ 110-7' f(~ lla tf)K T.!> C'O(/~/{ /(ooF I /()~ ,.rrn- '?J~ tOlr (0 (l 0 c/o(' If: ouTs' Pi" ..s. r /',.. /" r..J 1/0-),"3 - ~(" /)11'..1 ;Vo 6f(OG/NOf o!'l.l'it~ ,f,seI?5 veT I Ito-'J!.- '()- /,11'--1 /?" (i,-eL.-v&- PI"rVl/.q ot{ , I I I I I~ I I~ I .::1: Ill) I I! I .Z I- . w I ,- I I~ I I~ I Ig I I I I I I I I I ~ ~ I . '. , I I/Or/tJ-fI fflE~ O.K. FOR COVERING I/~~ I '1'- n- -11 ?",,.e O.K. TO CONNECT SERVICE , 11/- /Li- '65""' ?/fiJ FINAL O.K. I- I I J r7 D "!:'t"f, CITY OF PORT ANGELES 000389 / - DEPARTMENT OF LIGHT A FEE RECEIPT NUMBER PERMIT NUMBER 1- APPLICATION AND ELECTRICAL PERMIT .. j / t ~--~-+-1e_,w.t Lei '''ti:- (. ~ e 6' 1\1"yt TOTAL FEE - -., , . I CONT. Lie, NO. TIME TO COMPLETE NO. STORIES LEGAL OCCUPANCY ..~ . NO OCCUPANCY OR USE ESTABLISHED UNDER THIS PERMIT ELECTRICAL PERMIT ONLY Site Addres. - II {I ~. ALP t:.- R. -. . . '. I CaRR CT AODRESS 'S RE~PONS'B'L1TY OF APPLICANT PERMITS WIT~ WR9NG ADDR~SSES ~RE CANCElL~D .-.- Owner fiLl I? c. <: 1\ KIN (r Installation By Iv! ("' hi tl I.le:.# ;:: I ~ <- J Owner's Address /In Nc At Oc- R Installers Address ":l I')"f W S Ie uhf Jl J I Installers Phone -;;.C'{ - "T'I-.r:-7"~qJ Day Phone . I Po' Application is hereby made for Permit to install Electrical Equipment as follows: : ., AIIn?.";: MfttJcle- &fl!<"7 1)c.J;</,,-R r - Wjring Methqrl NUMBER AMP 12QV 240V NUMBER AMP 120V 24QV USE OF CIRCUIT PER 100A FEE USE O-F CIRCUIT PER 100R FEE' CIRCUITS CIR 10 30 (\ CIRCUITS CIR 10 30 , . LIGHT l",N' _ UGHT .50 VOL TS-./ OR LESS CONVENIENCE {: MOTOR? I CONVENIENCE C MOT.rn I I , APPLIANCE MOTOR 1 I I r DISHWASHER r RE ALARMS I I , DISPOSAL BURGLAR ALARM I I I , . - RANGE I 'J) MISC. I.: I / .I ./ . OVE~ I ../ I I I I I WAT~R HEATER r .) I I I I I I .- lAU~DRY < I I I I I I .., DRYER 1..", I REINSTALLATION UGHT FIXTURE # , FURNACE /, I ',] II SU~ TOTAL FEE I GAS'" Oll- I FURNACE Ii. :: .'.:!J ENERGY FEE 'ELEOTRIC II BASIC FEE I I EL~CTRI~ HEAT (j '7 I, TOTAL FEE. I I ELECTRIC HEAT I SIZE OF SERVICE SWITCH OR CIRCUIT BREAKER A.C. UNIT AMP PHASE . , I FEEDER I SIZE OF SERVICE ENTRANCE CONDUCTORS I SERVICE II AW.G. I SUB-TOTAL II SIZE OF GROUND SIZE OF ENTRANCE SWITCH -- - .. . I certify that the work to be performed under this permit will be done by the installer and in conformance with the N.E.C. Electrical Code.. Date Application mad"" <;Sr .ll .10 frr By \>\.1JR J( M rlUcLe 'I1eJ7 ~ ' . CONTRACTOR OR OWNE~ (OR AUTHORIZED AGENT} _ Permission is hereby. given to do the above described work,' according to the conditioris hereon and according to the approved.plan-s and' specifications pertaining thereto, subject to compliance with the Ordinances of the City of Port Angeles. . '. DIREC~ITY LIGHT . . B 11~/ e~ . Date PermIt Issued PCANS APP 0 ED . . ~~ c/ 15'-'" )l '" rr Notify Department of City light by Street Address and Permit Number when ready f~r inspectio~. Work must not be covered or current turned on before inspection and O.K. for covering or service has been given by Inspector in I I Writing on Permit Placard. A. ' Permits Phone: 457,0411 Ext. 158. ~ WARNING PERMIT PLACARD MUST BE KEPT POSTED ON THE WORK - SEE OVER _ WHITE - Original CANARY. Duplicate PINK. Triplicate WHITE CARD. Inspector's Report '"'I VUl:llr. PR1I\ITI=R<: 11\Ir. REPORT OF INSPECTOR ~ '.J DATE OF VISIT MADE BY REMARKS 1. I . I I I I . I , I .J , I -j I I I I I I I I I I I I I , I I I I I I I I \ -I ~ I I I , II: . c( I I I \ :E ~ I I I \ \ Ii: , I I . I~ . I \. I- I II;. I I I \ \ I~ I I \ \ ,g I I I , \ I , \ I I ~ I I I I I I I I I I I I I I I I It-)7-s- 1!/~ ~ K t:e/VIf ~R../Il\ "j , I ( I O.K. FOR COVERING I OK TO CONNECT SERVICE I I 7'- If -<6'.)1' 11t'~ FINAL O.K. i. I I J 08/26/2008 08:06 360-681-7272 JARMUTH ELECTRIC PAGE 01 - -'\\ . ELECTRIfh: WORKPERMlT APPLICATION \J / 'Zm~1 r q;I ?' ~ ~eetrical Contractor ~tion descriptiOIl , Job wired by o Owner Commercial a RetldenUBI ~ "':-- Ele~ical contfBClor name L_e number Date Expirel!l o Altered! Addition \) ......,., ~ h. E"J c.c..J..nc:... ,j.,-, c- Purchaser's mailing address k S I- k~f~ ~ 3</DJ Yv' W_C"ti ..::J01:) A- (.1;\\ Cs la" ZIP c.~"<.:""- WA- "8'3~ 2- Tetephd6e n.umber FAX number &,r/- 7;:2..72- (, So- 3 - ~/f)4j . 4f 6.tJ ~ zzs-:c: Premlnl owner'. Dame Ie II. , Addrel1 of InJPe(:tl~ 110 /J J'..rr- City ~ ~ (, tJ)-~ "'"" ",5 Pbone number to ach ull! lIupedloa: Owner as defined by RC'W'.19.28.26J:(1) Owner will occuPy the S"UC1Ur-e!OT two years after this electrical permit Is finalized. 0) Owntr Is required 10 hi~ 011 electrical conlractor if Goave said properly iJ for sale. rent Qr leQ.!e. o Casb o Check # After teading lhe: above statement, I nereby certify that I am tbe owner of the abovCl ~ditCard named propcny OT a licensed electrical contractor. I a.m. making the electrical instal- V... Ma.terclll'd Discover lalion OT alteration in compliance with the electrical laws. N.E.C., RCW. Chapter ~~El.I-::.--___------ 19.2&, WAC. Cnapter 296-46B, The City of Porl Angdc15 Municipal Code, and Cord # Utility Specificationll. SleD".'. of OWO."1"I.al 'oo"a~lo' OT ....t,l,al admlnlstratoT (InSpeCHon fee E~IrI~~~I"~btr8etlon~ate: r-.;Jt -pf{" S ~~,o7J "'Nice lnfatmatlon ~ 11I0 LOAD CHAN S VoIlago 12. O/W(f IJ Boseboard _KW ~head Servlee CI Fumace - KW Phose (;I 1 jli'3 CJ Heal Pump - Ton - LAR emp Service Sorvlee Slzo: IJ Fan-Wall _KW o Underground Service Feeder Size: SAME DAY INSPECTION. CALL BEFORE 7:00 AM 360-417.4735 ( ROUGH-IN ) lllERMOSfAT ~ SFBWCE ) 0111' ^pF'f'lwllllllly - " 0.1(: APPfflVrod By PI <f.l#f1 ]f., ., FiNAL DITCH ( ru>>_ ) 9ll~?~ ~} D~' Dill:: Approved ily " 01111 Approved By Inspection I , Date Area, Building or Equipment Inspected Action Taken ElectTical e - 2.(, -og I CI< NO ('~~1...J;:C'T" rEf;" f!Ev/n,JEi!J ;;.:~1-J I I I I I I ~~C\EU,'~\UJ I I ,:..UG ~ :; ~19g I I ---~2t ----~-_. - .-- , I I ;; ! I --~. - - -- u.srZuileuivk ariu Ili!Jt rax 4125 yliti 6501 Sea —Copy 10002 /002 After reading the above statement, I hereby certify that I am the owner of the above named property or a licensed eiectrical contractor. I am making the electrical installation or alteration in compliance with the electrical laws, N.E.C., RCW. Chapter 19.28, WAC. Chapter 296 -4613, The City of Port Angeles Municipal Code, and Utility Specifications and PAW 14.05.050 regarding Electrical Permit Applications. Signature of owner, electrical contractor or electrical administrator: ❑ cash ❑ cheek ❑ Credit Card 4 ! ozil Dated: 0 116112 01 2 a v��, pQRrq,�r F It RMEIVE-D CITY OF PORT ANGELES PERMIT APPLICATION Building Division /Electrical Inspections 1,4AR 2014 ,_ �... n v t 321 >ai►st Fit'tli Street — P.O. Box 1150 /Port Angeles Washington, 983 '° Ph: (360) 417 -4735 Fax: (360) 417 -4711 ELECTRICAL � Date; aLoij / Y Multi- Family orCommerciar INSPECTION,i * Plan Review May BVequired, Please Complete Electrical Plan Review Information Sheet Job Address; k A �- Building Square Footage: car `n i A E? c , q X"V p m U Description of above C}�_� (' h An"� �,Y rr, i�Sir� f'✓i. — G t 'f l` ,' �' • ' - Owner In�,rmation` Name: :20' v^d C'_�eu ��,{ y �s��t Contractor Information C°C Name: d -';� °� — Mailing Address: PP !2 ra " 5� Mailing Address: J 61 Ce { , City: .`ia r 1A Slate, GZ Zip: 1' Cily; Xe A i• State: —Ek Zip, O' ' Phone: ,k�7,? �15sf �3 "fSS�ax: 5� • L • ' 6 4 Ll Phone: ' 2 F <o 0 Fax; Y2 r5e.?q6_ L License # 1 Exp. License #! Exp• Item Unit Charc�ye City Total (Qty Multiplied by Unit Char gel Service /Feeder 200 Amp, $132.00 $ Service /Feeder 201 -400 Amp. $160.00 $ Service /Feeder 401.600 Amp $ 225.00 $ ServicelFeeder 601 -1000 Amp. __ $ 288.00 $ Service/Feeder over 1000 Amp. $ 410.00 $ Branch Circuit WlService Feeder $ 5.00 $ Branch Circuit 1N10 Service Feeder $ 74.00 $ Each Additional Branch Circuit _ $ 5.00 $ �_ Branch Circuits 1 -4 $ 86.00 $ Temp. Servicel Feeder 200 Amp. $102.00 $ Temp, Service /Feeder 201.400 Amp. $121.00 _ $ Temp. ServicelFeeder 401 -600 Amp. $164,00 $ Temp, Service /Feeder 601 -1000 Amp • _ $185.00 _ $ Portai to portal Hourly $ 9$•00 $ -- Sign /Outline Lighting $ 88.00 $ �'- Signal Circuit] Limiled Energy — Multi - Family $ 64.00 _ Signal Circuitl Limited Energy / First 1500 sf — Commercial $ 96.00 $ Note: $5.00 for each additional 1500 sf Renewable Electrical Energy - 5KVA System or Less $113,00 $ Thermostat _ $ 56.00 $ Note; $5.00 for each additional T -Scat µ $ G U U Total Owner as defined by RCW. 19.28.261: (1) Owner will occupy the structure for two years after this electrical permit is finalized. (2) Owner is required to hire an electrical contractor if above said property is for sale, rent or lease. Permit expires after six months of last inspection. After reading the above statement, I hereby certify that I am the owner of the above named property or a licensed eiectrical contractor. I am making the electrical installation or alteration in compliance with the electrical laws, N.E.C., RCW. Chapter 19.28, WAC. Chapter 296 -4613, The City of Port Angeles Municipal Code, and Utility Specifications and PAW 14.05.050 regarding Electrical Permit Applications. Signature of owner, electrical contractor or electrical administrator: ❑ cash ❑ cheek ❑ Credit Card 4 ! ozil Dated: 0 116112 01 2 INSPECTION TYPE DATE: RESULTS: INSPECTOR: DITCH SERVICE ROUGH -IN FINAL COMMENTS: PERMIT WILL EXPIRE SIX (6) MONTHS FROM LAST INSPECTION Signature of owner or Electrical Contra_ ctor X Date: G:IEXCHANGEWILDING .r C� ELECTRICAL PERMIT CITY OF PORT ANGELES 360- 417 -4735 Application Number 14- 00000357 Date 3/25/14 Application pin number , . 596857 Property Address , , , , . 110 N ALDER ST ASSESSOR PARCEL NUMBER: 06-30-00-5-6- 0125 -0000- 1� REPORT SALES TAX Applieation type deacript.ion ELECTRICAL ONLY on your excise tax form Subdivision Name Proper ty Use to the City Oi Port Angeles Property Zoning , , , . COMMERCIAL ARTERIAL n (Location Code O5OZ� Application valuation 0 -------------------------------------------- Application desc Camera IT space Owner Contractor QUINN GALE P ALLIED SAFE AND VAULT CO. 560 SE MIDWAY BLVD 3051 E VALLEY RD OAK HARBOR WA 982775016 RENTON WA 95057 (425) 988 -6500 Permit . , . , . . ELECTRICAL - ----------------------w_--_------ ALTER COMMERCIAL Additional desc , . Permit Fee 96.00 Plan Check Fee 00 Issue Date . . . . 3/25/14 Valuation p 8xpiration Date 9/21/14 Qty Unit Charge Per Extension 1.00 96,0000 ECH EL- LIMITED I8T 1500 SQ FT 96,00 Fee summary Charged ------------'------------------ Paid ,Credited Due Permit :Fee Total 96.00 --- ---- - -- --- -- -- - - -- -- 96.00 ,00 ,00 Plan Check Total ,00 .00 ,00 00 Grand Total 96,00 96.00 .00 00 INSPECTION TYPE DATE: RESULTS: INSPECTOR: DITCH SERVICE ROUGH -IN FINAL COMMENTS: PERMIT WILL EXPIRE SIX (6) MONTHS FROM LAST INSPECTION Signature of owner or Electrical Contra_ ctor X Date: G:IEXCHANGEWILDING .r C�