Loading...
HomeMy WebLinkAbout1418 S Cherry St - BuildingCITY OF PORT ANGELES DEPARTMENT OF COMMUNITY DEVELOPMENT BUILDING DIVISION 321 EAST 5TH STREET PORT ANGELES, WA 98362 Application Number 08 00000709 Application pin number 024790 Property Address 1418 S CHERRY ST ASSESSOR PARCEL NUMBER 06 30 00 0 4 2085 0000 Tenant nbr name MIKE HOWELL Application type description MECHANICAL APPL PERMIT Subdivision Name Property Use Property Zoning Application valuation Application desc INSTALL A WOOD BURNING STOVE INSERT Owner MICHAEL JANEEN HOWELL 1418 S CHERRY ST PORT ANGELES (360) 565 1442 Permit Additional desc Permit pin number Permit Fee Issue Date Expiration Date Qty Unit Charge 1 00 Fee summary Permit Fee Total Plan Check Total Grand Total Date WA 98362 Per 10 6500 ECH Charged Paid 60 65 00 60 65 T.Forms /Building Division/Building (10 /01 /07).wpd RS7 RESDNTL SINGLE FAMILY 2334 MECHANICAL PERMIT WOOD STOVE INSERT 128223 60 65 Plan Check Fee 00 6/12/08 Valuation 2334 12/09/08 BASE FEE ME OTHER APPL Contractor Date 6/12/08 THURMANS SUPPLY 1807 EAST FRONT STREET PORT ANGELES WA 98362 (360) 457 8591 60 65 00 60 65 Extension 50 00 N/R 10 65 Credited Due 00 00 00 00 00 00 Separate Permits are required for electrical work, SEPA, Shoreline, ESA, utilities, private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days if construction or work is suspended or abandoned for a period of 180 days after the work has commenced or if required inspections have of been requested within 180 days from the last inspection I hereby certify that I have read and examined this application and kno e same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether spec'" d herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or loc- re /lating construction or the performance of construction. 2 �ar �V 1 i a. Y✓eAvt w et Y,./ G// 411.1 Printame Signature of Contractor or Authorized Agent I Signature of Owner Of owner is builder) CALL 417 -4815 FOR BUILDING INSPECTIONS CALL 417 -4735 FOR ELECTRICAL INSPECTIONS CALL 417 -4807 FOR PUBLIC WORKS UTILITIES PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED POST PERMIT IN A CONSPICUOUS LOCATION KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE. INSPECTION TYPE DATE FOUNDATION• FOOTINGS SHEAR WALLS WALLS FOUNDATION DRAINAGE DOWN SPOUTS PIERS POST HOLES (POLE BLDGS.) PLUMBING UNDER FLOOR SLAB ROUGH -IN WATER LINE (METER TO BLDG) GAS LINE BACK FLOW WATER AIR SEAL WALLS CEILING FRAMING JOISTS GIRDERS SHEAR WALL/HOLD DOWNS WALLS ROOF CEILING DRYWALL (INTERIOR BRACED PANEL ONLY) T -BAR INSULATION SLAB WALL FLOOR CEILING MECHANICAL HEAT PUMP FURNACE DUCTS GAS LINE WOOD STOVE PELLET CHIMNEY COMMERCIAL HOOD DUCTS MANUFACTURED HOMES FOOTING SLAB BLOCKING HOLD DOWNS SKIRTING PLANNING DEPT SEPARATE PERMIT N's PARKING /LIGHTING LANDSCAPING RESIDENTIAL ELECTRICAL LIGHT DEPT 417 -4735 CONSTRUCTION R.W PW/ ENGINEERING FIRE PLANNING DEPT BUILDING 417 -4807 417 -4653 417 -4750 BUILDING PERMIT INSPECTION RECORD SEPA. ESA. SHORELINE. FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE DATE YES NO COMMERCIAL I I 417 -4815 I X1)%1 'I 11 T Forms /Building Division /Building Permit (10 /01 /07).wpd ti ACCEPTED COMMENTS YES NO FINAL DATE FINAL DATE ELECTRICAL LIGHT DEPT CONSTRUCTION R.W PW ENGINEERING FIRE DEPT PLANNING DEPT BUILDING DATE ACCEPTED BY. ACCEPTED BY. ACCEPTED YES I NO 09 0 09 V J Applicant or Agent f l/I z,,e44./I S Property Owner k 7 Property Owner's Address'-'/y --c /_I ,,.,,,c4 Contractor/Engineer Contractor /Engineer's Address /gc7 ,L License `35 TE j ,r� PROJECT ADDRESS 5//g C C4— c Parcel Number Floor Areas Project Type Brief Description. VResidential Commercial Check all that apply New Construction Addition Remodel Repair Re -roof Demolition Heat System Other Basement 1 Floor 2 Floor 3 Floor Garage Carport Covered Porch Deck Shed Other BUILDING PERMIT APPLICATION Print in ink CITY OF PORT ANGELES Attn Building Permit Technician 321 E Fifth St. Port Angeles WA 98362 (360) 417 -4815 fax (360) 417 -4711 Existing (sa. ft.) Heat pump -wood- burning stove gas fireplace pellet stove other 71?S -e Proposed (sq. ft.) Total footprint of structures sq ft. Lot size Max height of proposed structures ft. Occupancy group Will a fawn sprinkler system be installed? Occupant load Will a fire sprinkler system be installed? Construction type Phone Phone Phone Expires Lot Zoning Multi- family Industrial per sq ft. TOTAL VALUATION 3 sq ft. Lot coverage of bedrooms of full baths of half baths I have read and completed this application and know it to be true and correct. I am authorized to apply fo understand that it is my responsibility to determine what permits are required, and to obtain rmits p projects. Print Name v� '�y.1.44 G YL T Forms /Building Division /Bldg Permit Appl. 2006 Code.doc For City Use Only Date Received (0— Permit# c3 -70�i Date Approved X77 Signature /�W is permit and to working on CITY OF PORT ANGELES PUBLIC WORKS - ELECTRICAL DIVISION 321 EAST 5TIt STREET. PORT ANGELES. WA 98362 ELECTRICAL PERMIT ISSUED: 10/17/2002 PERMIT NO 7860 OWNER/APPLICANT PROPERTY LOCATION MIKE AND JANINE HOWELL 1418 CHERRY S 1418 CHERRY Lot: 19,20 N1/2 Port Angeles, WA 98362 Block: 420 ~ Long Legal 360/565-1442 Subdivision: TPA T: S: Parcel No: 063000042085000 CONTRACTOR ARCHITECT OLYMPIC ELECTRIC N/A 4230 TUMWATER PORT ANGELES, WA 98362 , 98360-0000 360/457-5303 360/000-0000 -l~ PROJECT INFO Project Type: RES. MISC. Project Value: $0.00 ~ Occupancy Type: Construction Type: EL Occupancy Group: Zoning Use: RS7 (,J Electrical Heat: ~ Baseboard 0 KW ~ Riser ~ Underground Service [~i Furnace 0 KW j Overhead Service Voltage: 0 ( Ii ! Heat Pump 0 KW ] TempService Phase: I~ 1 ~l 3 ..~ I ! Fan Wall 0 KW Service Size: 0 I~ Feeder Size: 0 q PROJECT NOTES ~ 200 AMP SERVICE CHANGE OUT. BRANCH CIRCUITS ADDED OR ALTRERED. RECEIPT # 9774 FEES ASSESSMENT Service: $64.90 Additional Feeders: $0.00 Circuit Wiring: $0.00 Temp Service: $0.00 Misc Fee: $0.00 TOTAL FEE: $64.90 AMOUNT PAID: $64.90 BALANCE DUE $0.00 ('OMMENTS/ACTION NEEDED ELECTRICAL PERMIT INSPECTION RECORD CALL 417~1735 FOR ELECTRICAL I]qSPECTIONS. PLEASE PROVIDE A IVll]xqMUM 24 HOUR NOTICE. IT IS UNLA I. FFUL TO CO VER, INSULATE OR CONCEAL ANY WORK BEFORE IT IS INSPECTED AND ACCEPTED. KEEP PE1LM1T CARD AND APPROVED PLANS AT JOB SITE UNSPEC'TION TYPE [ DATE I ACCEPTED COM]klEINTS YI~ { NO DITCH ROUGH-IN / COVEP, SERVICE GENERAL COMMENTS: . Site Address: / (~U? .~t. t Installed By: OwnerfBusiness: Owner/Business Address: ELECTRIC HEAT o BASEBOARD KW _ o FURNACE KW _ o HEAT PUMP KW_ o FAN/WALL KW _ Details/Description: IJ-J-/) CITY OF PORT ANGELES LIGHT DEPARTMENT 321 E. Fifth Street Port Angeles, WA 98362 (206) 457-0411 PERMIT NO. 5' 5' II s-h kt~ DATE , - o READY FOR INSPECTION License Number: W.S. No. SERVICE SIZE CAPACITY: o O.K. 0 NOT O.K. ACTION REQUIRED: 0 CHANGE TRANSFORMER o INSTALL SERVICE POLE J t;r RESIDENTIAL tJ COMMERCIAL o NEW CONSTRUCTION o REMODEL ~ ADD/ALTER CIRCUITS o SERVICE UPGRADE/REPAIR o TEMPORARY SERVICE ~ cLU~ DATE o WILL CALL FOR INSPECTION Phone: Phone: Sq. Ft. o RISER j.1(OVERHEAD SERVICE o UNDERGROU/f SERVICE VOLTAGE: / ?t'? 2-</D . I E11rD 039\ SERVICE SIZE FEEDER SIZE AMPS AMPS . ENGR. o OVERHEAD SERVICE APPROVED o CHANGE SERVICE WIRE o OTHER o Ditch Inspection OX o Rough-in/cover O.K. o O. K. to connect service ~rinal OX Site Address: Installer: iL/lt M. ,to. Permit/Receipt No. 's:s,-I/ New Meters . Notify Port Angeles City Light by Street Address and Permit Numberwhen ready for inspection. Work must not be covered before inspection and O.K. for covering has been given by the electrical inspector in writing on either the Wiring Report or on the Building Permit. PHONE 457-0411, EXT. 224. - NO OCCUPANCY OR USE ESTABLISHED UNDER THIS PERMIT $ /(.~ Electricallnkpector WHITE - File by address OLYMPIC PAINTERS INC. PINK - Top: Eng, Bottom, Customer ." .3.0 Permit Fee GREEN - Top: MeIer Dept., Bottom: City Hall i. L (fvo~u'r<;r ~S~iL~ID(0 .~ ... " PORT ANGELES HOUSING REHABILITATION PROGRAM 129 1st St Port Angeles, WA 98362 Telephone #452-2@23 February 22, 1996 (revised February 26, 1996) Final worklist specifications for: Cyril and Debra Snyders 1418 S Cherry Street Port Angeles. WA 98362 Telephone #452-4272 Project A (REQUIRED HEALTH AND SAFETY REPAIRS) 0400 1)Repair the top of the chimney servicing the oil fired boiler. 2)Repoint and cap the exposed upper section (10 rows) of the fireplace chimney. Install a new chimney flu cap. Include repair/patching of the stucco near the base of the chimney. 1500 l)Basement: Install a proper extension pipe on the water heater pressure relief valve. 2)Basement: Replace a leaky/defective pressure relief valve on the hot water heat boiler. ~00 l)Install new hardwired smoke alarms with battery backup throughout the house to code. Alarms to be inter-tied. 2)Safe-up electrical wiring, outlets, fixtures, junction boxes and connections throughout the house. All fixtures and I ~connections to have proper junction boxes. Insure that all ~ 3-prong outlets are properly grounded and that all other outlets have correct polarity. Insure that panel is properly wired and labeled. All fixtures, outlets, and switches to have proper cover plates. Inspect attic knob and tube wiring and safe-up and prep for additional insulation. 1 , rf "..,.. 3)Rear kitchen entry: Install (2) new exterior security ~i9hts and connect to existing switch located inside the kitchen entry. 4}Kitchen. Install a new GFCI protected outlet near the ~iink to replace an existing outlet. })-Main floor bathroom. Install a new GFCI protected outlet ~/'near the sink. /- ~iving room: Insure that all outlets are properly ~connected and working. ~il~asement: Insure that the water heater is properly wired. ~asement office area: Install (2) additional outlets. t/H~;eowner to designate location. .9tBasement. living room and SW bedroom: Reconnect existing 0ixtures and outlets and separate circuits as necessary for proper safe-up. ~)Properly install the switch located near the laundry ~area. Include a cover plate. ~)Basement entry: Install a new exterior entry light fixture. ~~pper bathroom: Install a new GFCI protected outlet near the sink. ~upper east bedroom: Install a new ceiling light fixture v/and switch to be located near the doorway. ~pper east bedroom alcove area: Install a new ceiling light fixture and switch to be located near the doorway. ~~per SW bedroom: Install a new ceiling light fixture and ~;~i~ch to be located near the doorway. 1 ~uPper North bedroom: Install a new ceiling light fixture ~;~~ switch to be located near the doorway. PROJECT B (COST EFFECTIVE ENERGY CONSERVATION) 'i 0700 l)Basement. Install rim and end joist and ceiling insulation with tyvek covering. 2)Insulate the perimeter exterior walls with blown insulation. 2 / '. " 3)Insulate the attic and knee wall areas to R-38. 0800 1) Rear kitchen entry: Install a new threshold and weather strip kit and adjust door for proper operation. 2)Basement: Install (2) new vinyl framed slide-by windows with insulating glass near the northeast corner. Replace dry-rot damaged window framing. Trim and finish the exterior. Homeowner to stain and finish or paint the trim. 3)Basement: Install (2) new vinyl framed slide-by windows with insulating glass on the west wall. Replace dry-rot damaged window framing. Trim and finish the exterior. Homeowner to stain and finish or paint the trim. 1100 l)Upper bathroom: Install a new ceiling exhaust fan/light ~combination and connect to new separate switches to be V located near the doorway. Insure proper. venti.n.s--to the exterior. 21Main bathroom: Install a new wall , ~With proper venting and a switch to tv' doorway. or ceiling exhaust fan be located near the PROJECT C (EXTERIOR DETERIORATION) 0600 l)Rear kitchen entry steps and walkway: Replace damaged support posts and dry-rot damaged framing and steps. Eliminate all earth/wood contact. 0700 l)Tear off the existing shake roofing, resheath. and reroof the entire house with 25 year 3-tab composition seal down shingles. Homeowner to dispose of shake roofing. PROJECT D (BUILDING CONSERVATION) 0500 l)Install new seamless aluminum raingutters, downspouts, and splash blocks around the perimeter eave areas. Note: contractor bids to include permit fees and applicable tax. Bid all projects separately. 3