Loading...
HomeMy WebLinkAbout710 Estes Ct - Building $e ~~ -" . ., ~ CITY OF PORT ANGELES PUBLIC WORKS - ELECTRICAL DMSION 321 EAST 5TI1 STREET, PORT ANGELES, WA 98362 ELECTRICAL PERMIT Issued: 3/05/97 Permit No: 5857 OWNER/APPLICANT------------------------PROPERTY LOCATION------------------------ GARY SMITH 710 ESTES COURT 710 ESTES COURT Lot: 24 (SL39) Port Angeles, WA 98363 Block: Long Legal: 360/452-3684 Sub: MILWAUKEE HEIGHTS II T: S: parc No: CONTRACTOR----~------------------------DESIGNER--------------------------------- SHAMP ElLECTRIC 1112 W. 15TH Port Angeles, WA 98362 360/452-1689 , 000/000-0000 PROJECT INFO---------------------------------------------------------------_____ prj Tlpe: RES.NEW prj Value: $0.00 Occ Type: Cnstr Type: Occ Qrp: Occ Load: Land Use: RS9 Electrical Heat Service Type X Baseboard KW: 3 Riser Voltage: 120,240 Furnace KW: 0 Overhead Service Diameter: X-I -3 Heat Pump KW: 0 X Underground Service Service Size: 200 AMPS X Fan/Wall KW: 6 Temp Service Feeder Size: 0 AMPS PROJECT NOTES----------------------------------------------_____________________ 3KW BASEBOARD, 6KW WALL FAN PROJECT FEES ASSESSMENT------------------------------------_____________________ Service: $80.00 Additional Feeders: $0.00 Circuit Wiring: $0.00 Temp Service: $0.00 : $0.00 Misc TOTAL FEE: Amount Paid: $80.00 $80.00 ======================~========== -------------------------- TOTAL FEE: $80.00 Balance Due: $0.00 COMMENTS/ACTION NEEDED ----, -' ELECTRICAL PERMIT INSPECTION RECORD CALL 417-4735 FOR ELECTRICAL INSPECTIONS. PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNbJ WFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE IT IS INSPECTED AND ACCEPTED. KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE INSPECTION TYPE DATE ACCEPTED COMMENTS YES I NO DITCH .. 7c:;o-..., -IN I 7 'I,,",^,," SERVICE .;, f7/47 ~ , FThl A T I I GENERAL COMMENTS: PW-II02.15(4I96) I l ti ~ii? CITY OF PORT ANGELES PUBLIC WORKS - ELECTRICAL DMSION 321 EAST 5TH STREET, PORT ANGELES, WA 98362 -~ ELECTRICAL PERMIT Issued: 1/24/97 Permit No: 5798 OWNER/APPLICANT------------------------PROPERTY LOCATION------------------------ GARY SMITH 710 ESTES COURT 710 ESTES COURT Lot: 24 Port Angeles, WA 98363 Block: Long Legal: 360/452-3684 Sub: MILWAUKEE HEIGHTS II T: S: Pare No: CONTRACTQR-----------------------------DESIGNER--------------------------------- SHAMP E1LECTRIC 1112 W. 15TH Port Angeles, WA 98362 360/4521-1689 , 000/000-0000 PROJECT ~NFO-------------------------------------------------------------------- prj Type: TEMPORARY SVC. prj Value: $0.00 Occ Type: Cnstr Type: Occ Qrp: Occ Load: Land Use: RS9 Electrical Heat Service Type Bas;eboard KW: 0 Riser Voltage: 0 Furnace KW: 0 Overhead Service Diameter: -1 -3 Hea;t Pump KW: 0 X Underground Service Service Size: 0 AMPS Fan/Wall KW: 0 X Temp Service Feeder Size: 0 AMPS PROJECT ~OTES-----------------------------------------------------------------~- PROJECT FEES ASSESSMENT--------------------------------------------------------- Service: $0.00 Ad~itiona1 Feeders: $0.00 Circuit Wiring: $0.00 Temp Service: $35.00 $0.00 Mise TOTAL FEE: ,Amount Paid: $35.00 $35.00 ================================= TOTAL FEE: $35.00 Balance Due: $0.00 COMMENTS/ACTION NEEDED ELECfRlCAL PERMIT INSPECfION RECORD CALL 417-4735 FOR ELECTRICAL INSPECTIONS. PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE IT IS INSPECTED AND ACCEPTED. KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE INSPECTION TYPE DATE I ACCEPTED COMMENTS I YES I NO DITCH . I-iN I CUYbR E 11~"/4 7 I tOM.. FINAL I I I GENERAL COMMENTS: PW-II02.l5(4I96] M:._._. REPORT STArE SALO TAX on y+r w eXGi8E3tom' to the City of Poif A 1" (Location Code -0502) 1 6 INSPECTION TYPE DATE: RESULTS: INSPECTOR.: DITCH l SERVICE ROUGH -IN FINAL 4�-, COMAENTS: PERMIT WILL SIRE SIX (6}MONTHS FROM LAST INSPECTION Signature of owner or Electrical Contractor X Date: ELECTRICAL PERMIT CITY OF PORT ANGELES 360.417-4735 Application Number . . . . . 18-00000654 Date 5/01/18 Application pin number . . . 849204 Property Address . . . . . . 710 ESTES CT ASSESSOR PARCEL NUMBER: 06 -30 -00 -4 -5 -0240 -0000 - Application type description ELECTRICAL ONLY Subdivision Name . . . . . . Property Use . . . . . . . . Property Zoning . . . . . . . RS9 RESDNTL SINGLE FAMILY Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc Ductless heat pump ---------------------------------------------------------------------------- Owner Contractor ------------------------ MICHAEL W AND KARISSA a FRENCH ------------------------ BLACK DIAMOND ELECTRICAL CONTR 710 ESTES CT 502 BLACK DIAMOND RD PORT ANGELES WA 98363 PORT ANGELES WA 98363 (360) 565-1035 ---------------------- — ---------------------------------------------------- Permit . . . . . . ELECTRICAL ALTER RESIDENTIAL Additional desc . Permit Fee . . . . 63.00 Plan Check Fee .00 .Issue Date . . . . 5/01/18 valuation 0 Expiration Date . . 10/28/18 Qty Unit Charge Per Extension 1.00 63.0000 ECH EL -R- BRANCH CIR WO/ SER FEED 63.00 ---------------- ----------------------------------------------------------- Fee summary Charged ----------------- ---------- Paid Credited Due ---------- ---------- ---------- Permit Fee Total 63.00 63.00 .00 .00 Plan Check Total .00 .00 .00 .00 Grand Total 63.00 63.00 .00 .00 M:._._. REPORT STArE SALO TAX on y+r w eXGi8E3tom' to the City of Poif A 1" (Location Code -0502) 1 6 INSPECTION TYPE DATE: RESULTS: INSPECTOR.: DITCH l SERVICE ROUGH -IN FINAL 4�-, COMAENTS: PERMIT WILL SIRE SIX (6}MONTHS FROM LAST INSPECTION Signature of owner or Electrical Contractor X Date: Project Address: Description: 1- 2 SINGLE-FAMILY ,y . s s 4 3 ELECTRICAL PERMIT APPLICATIOI`*�. Public Works and Utilities Department 321 E. nth Street, Port Angeles, WA 9$362 360,4117.4735 www.cityofpa.us electricalpermits@cityofpa.us ?to re- s7—J Gf' )Single -Family Residential ❑ Duplex /ARU Building Square footage: OWNER INFORMATION Name: F/Zq_� C- (-i- Email: Mailing Address: —2 (co e Sr1'; c—T Name: Mailing Address: Email: Item Service/Feeder 200 Amp. Service/Feeder 201-400 Amp. Service/Feeder 401-600 Amp. Service/Feeder 601-1000 Amp. Service/Feeder over 1000 Amp. Branch Circuit W/ Service Feeder Branch Circuit W/O Service Feeder Each Additional Branch Circuit Branch Circuits 1-4 Temp. Service/Feeder 200 Amp. Temp. Service/Feeder 201-400 Amp. Temp. Service/Feeder 401-600 Amp. Temp. Service/Feeder 601-1000 Amp. Portal to Portal Hourly Signal Circuit/Limited Energy - 1&2 DU. Manufactured Home Connection Renewable Elec. Energy: 5KVA System or less Thermostat (Note: $5 for each additional) First 1300 Square Feet Each Additional 500 square feet' Each Outbuilding / Detached Garage Each Swimming Pool / Hot Tub Unit Charge Quantity $120.00 $146.00 $205.00 $262.00 $373.00 $5.00 $63.00 $5.00 $75.00 $93.00 $110.00 $149.00 $168.00 $96.00 $64.00 $120.00 $102.00 $56.00 $120.00 $40.00 $74.00 $110.00 TOTAL Phone: y & t —6 i? Z License: Expiration Date: Phone: Total (Quantity x Unit Charge) $,m $ $ Owner as defined by RCW. 19.28.261: (1) Owner will occupy the structure for two years after this electrical permit is finalized. (2) Owner is required to hire an electrical contractor if above said property is for sale, rent or lease. Permit expires after six months of last inspection. After reading the above statement, I hereby certify that I am the owner of the above named property or a licensed electrical contractor. 1 am making the electrical installation or alteration in compliance with the electrical laws, N.E.C., RCW. Chapter 19.28, WAC. Chapter 296- 46B, The City of Port Angeles Municipal Code, and Utility SpecifficatOons and PAMC 14.05.050 regarding Electrical Permit Applications. Date Print Name 0 S�nature�Owner ❑ Electrical Contractor/ Administrator) [Electrical Permit Applications may be submitted to City Hall or electricalpermits@cityofpa.us or faxed to 360.417.4711] Application Number . . . . . 23-00000799 Date 7/31/23 Application pin number . . . 261755 Property Address . . . . . . 710 ESTES CT ASSESSOR PARCEL NUMBER: 06-30-00-4-5-0240-0000- Application type description ELECTRICAL ONLY Subdivision Name . . . . . . Property Use . . . . . . . . Property Zoning . . . . . . . RS9 RESDNTL SINGLE FAMILY Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc PV system ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ MICHAEL W AND KARISSA J FRENCH LUMIO HX, INC 710 ESTES CT 1550 W DIGITAL DR PORT ANGELES WA 98363 LEHI UT 84043 (360) 637-4343 ---------------------------------------------------------------------------- Permit . . . . . . ELECTRICAL ALTER RESIDENTIAL Additional desc . . Permit Fee . . . . 120.00 Plan Check Fee . . .00 Issue Date . . . . 7/31/23 Valuation . . . . 0 Expiration Date . . 1/27/24 Qty Unit Charge Per Extension 1.00 120.0000 ECH EL-0-200 SRV FEEDER 120.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 120.00 120.00 .00 .00 Plan Check Total .00 .00 .00 .00 Grand Total 120.00 120.00 .00 .00 Public Works and Utilities Department 321 E. 5th Street, Port Angeles, WA 98362 360.417.4735 | www.cityofpa.us | electricalpermits@cityofpa.us EL1-2 SF 1 - 2 SINGLE-FAMILY ELECTRICAL PERMIT APPLICATION Project Address: Project Description: Single-Family Residential Duplex / ARU Building Square footage: OWNER INFORMATION Name: Email: Mailing Address: Phone: ELECTRICAL CONTRACTOR INFORMATION Name: License: Mailing Address: Expiration Date: Email: Phone: PROJECT DETAILS Item Unit Charge Quantity Total (Quantity x Unit Charge) Service/Feeder 200 Amp. $120.00 $ Service/Feeder 201-400 Amp. $146.00 $ Service/Feeder 401-600 Amp. $205.00 $ Service/Feeder 601-1000 Amp. $262.00 $ Service/Feeder over 1000 Amp. $373.00 $ Branch Circuit W/ Service Feeder $5.00 $ Branch Circuit W/O Service Feeder $63.00 $ Each Additional Branch Circuit $5.00 $ Branch Circuits 1-4 $75.00 $ Temp. Service/Feeder 200 Amp. $93.00 $ Temp. Service/Feeder 201-400 Amp. $110.00 $ Temp. Service/Feeder 401-600 Amp. $149.00 $ Temp. Service/Feeder 601-1000 Amp. $168.00 $ Portal to Portal Hourly $96.00 $ Signal Circuit/Limited Energy - 1&2 DU. $64.00 $ Manufactured Home Connection $120.00 $ Renewable Elec. Energy: 5KVA System or less $102.00 $ Thermostat (Note: $5 for each additional) $56.00 $ First 1300 Square Feet $120.00 $ Each Additional 500 square feet`` $40.00 $ Each Outbuilding / Detached Garage $74.00 $ Each Swimming Pool / Hot Tub $110.00 $ TOTAL $ required to hire an electrical contractor if above said property is for sale, rent or lease. Permit expires after six months of last inspection. After reading the above statement, I hereby certify that I am the owner of the above named property or a licensed electrical contractor. I am making the electrical installation or alteration in compliance with the electrical laws, N.E.C., RCW. Chapter 19.28, WAC. Chapter 296- Date Print Name Signature (Owner Electrical Contractor / Administrator) New Construction Only [Electrical Permit Applications may be submitted to City Hall or electricalpermits@cityofpa.us or faxed to 360.417.4711] COVER SHEETPHOTOVOLTAIC ROOF MOUNT SYSTEM710 S ESTES CT, PORT ANGELES, WA 98363, USAREVDATEDESCRIPTIONVERSIONUR07/13/2023INITIAL RELEASESHEET NAMESHEET NUMBERPV-0 PROJECT NAMESHEET SIZEANSI B11" X 17"KARISSA FRENCH 710 S ESTES CT, PORT ANGELES, WA 98363, USA APN# 0630004502400000 UTILITY: PORT ANGELES AHJ: CITY OF PORT ANGELES PROJECT NUMBER: P-0081505 07/22/2023REVISIONA16 MODULES-ROOF MOUNTED - 6.400 kWDC, 4.640 kWACGOVERNING CODES:2020 NATIONAL ELECTRICAL CODE (NEC)2018 INTERNATIONAL BUILDING CODE2018 INTERNATIONAL EXISTING BUILDING CODE2018 INTERNATIONAL SWIMMING POOL AND SPA CODE2018 INTERNATIONAL FIRE CODE2018 WASHINGTON STATE ENERGY CODE2018 INTERNATIONAL RESIDENTIAL CODE2018 INTERNATIONAL MECHANICAL CODE2018 UNIFORM PLUMBING CODE2VICINITY MAPSCALE: NTSPV-01AERIAL PHOTOSCALE: NTSPV-0SHEET INDEXPV-0COVER SHEETPV-1SITE PLAN WITH ROOF PLANPV-2ROOF PLAN WITH MODULESPV-3ATTACHMENT DETAILSPV-4 ELECTRICAL LINE DIAGRAM WITHCALCULATIONPV-5 WARNING LABELS & PLACARD PV-6+EQUIPMENT SPEC SHEETSNOTES:1.PHOTOVOLTAIC SYSTEM EQUIPMENT SHALL BE INSTALLED INACCORDANCE WITH NEC 2020 ARTICLES 690 AND 705, AND THE 2018IRC/IBC & 2018 INTERNATIONAL FIRE CODE, AND APPLICABLEREQUIREMENTS OF THE SERVICE UTILITY AND AUTHORITY HAVINGJURISDICTION. PHOTOVOLTAIC SYSTEM EQUIPMENT WILL BE POSTEDWITH APPLICABLE WARNINGS, SIGNAGE AND PLAQUES PER NEC 690.13,705.10 AND 706.15.2.PHOTOVOLTAIC SOURCE AND OUTPUT CIRCUITS SHALL COMPLY WITHTHE WIRING METHODS AND INSTALLATION AND MARKINGREQUIREMENTS OF NEC 690.31(D).3.BREAKER LABELED "PHOTOVOLTAIC ELECTRIC POWER SOURCE" AND"BREAKERS ARE BACK FED" PER NEC 705.12(D) & NEC 690.59. BREAKERALSO LABELED "MAXIMUM AC OUTPUT CURRENT AND OPERATING ACVOLTAGE" PER NEC 690.54. BREAKER SHALL BE POSITIONED AT THEOPPOSITE (LOAD) END FROM THE INPUT FEEDER OR MAIN CIRCUITBREAKER LOCATION, AND LABELED "WARNING INVERTER OUTPUTCONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE", PERNEC 705.12 (B)(3)(2).4.WARNING SIGN PER NEC 706.15(C)(4) and NEC 690.13(B) READING"WARNING - ELECTRIC SHOCK HAZARD - TERMINALS ON BOTH LINE ANDLOAD SIDES MAY BE ENERGIZED IN THE OFF POSITION."5.LABEL "PHOTOVOLTAIC SYSTEM UTILITY DISCONNECT SWITCH." SWITCHTO BE LOCKED PER NEC 690.13(B). SWITCH TO BE VISIBLE BLADEDISCONNECT PER UTILITY REQUIREMENTS AND CONFORM TO NEC705.22.6.LABEL "PHOTOVOLTAIC ARRAY DC DISCONNECT SWITCH" PER NEC690.13(B). LABEL WITH OPERATING CURRENT, OPERATING VOLTAGE,MAXIMUM SYSTEM VOLTAGE, AND SHORT CIRCUIT CURRENT PER NEC690.53. SWITCH LOCKED PER NEC 690.13(B).7.LISTING AGENCY NAMES AND NUMBERS TO BE INDICATED ON POWERINVERTER(S) AND SOLAR MODULES PER NEC 110.3 (B).8.LABELED PHOTOVOLTAIC SYSTEM DEDICATED KWH METER. (NOT USED)9.BI-DIRECTIONAL METER TO BE INSTALLED BY UTILITY.10.DEDICATED PHOTOVOLTAIC COMBINER SUB-PANEL. LABEL "LOADS NOTTO BE ADDED TO THIS PANEL."11.ALL LABELS EXPOSED TO SUNLIGHT MUST BE ENGRAVED ANDATTACHED PER APPROVED METHOD.12.LABEL "BREAKER HAS BEEN DE-RATED PER NEC 705.12(D)(2)." NO NEWLOADS.13.EXISTING EQUIPMENT IS NOTED WITH A DASHED LINE. SOLID LINESDENOTE EQUIPMENT INSTALLED BY ELECTRICAL CONTRACTOR.14.WIRE MAY BE RUN SHORT DISTANCES OUTSIDE OF CONDUIT IF WIREREADS "SUNLIGHT RESISTANT."15.THE GROUNDING ELECTRODE CONDUCTOR SHALL BE CONTINUOUS ANDTERMINATE WITH AN IRREVERSIBLE CONNECTION TO THE ACGROUNDING ELECTRODE SYSTEM PER NEC 250.64(B).16.AMBIENT TEMPERATURE ADJUSTED FOR CONDUITS EXPOSED TOSUNLIGHT ON OR ABOVE ROOFTOPS PER TABLE 310.15 (B)(2). CONDUITELEVATED MIN. 1/2"; ADDER 33 DEG F.17.ALL EXTERIOR EQUIPMENT TO BE NEMA 3R.18.THE PHOTOVOLTAIC POWER SOURCE SHALL BE LABELED WITH THEFOLLOWING WARNING AT EACH JUNCTION BOX, COMBINER BOX,DISCONNECT AND DEVICE WHERE ENERGIZED, UNGROUNDED CIRCUITSMAY BE EXPOSED DURING SERVICE: WARNING: ELECTRIC SHOCK HAZARD. THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZEDSYSTEM SUMMARY:(N) 16 - HANWHA Q CELLS Q.PEAK DUO BLK ML-G10+ / t (400W) MODULES(N) 16 - ENPHASE ENERGY IQ8PLUS-72-2-US MICRO-INVERTERS [240V](N) JUNCTION BOX(E) 200A MAIN SERVICE PANEL WITH (E) 200A MAIN BREAKER(N) ENPHASE IQ COMBINER 4 [240V]X2-IQ-AM1-240-4 (IEEE 1547:2018)(N) 30A NON FUSED VISIBLE, LOCKABLE,LABELLED HEAVY DUTY AC DISCONNECT [240V]ROOF TYPE: - ASPHALT SHINGLESNUMBER OF LAYERS: - 01ROOF FRAME: - 2"X4" TRUSSES @ 24" O.C.STORY: - TWO STORYSNOW LOAD : - 25 PSFWIND SPEED :- 110 MPHWIND EXPOSURE:- DRISK CATEGORY:- IICOORDINATE:- 48.131401, -123.481931DESIGN CRITERIA:710 S ESTES CT,PORT ANGELES, WA98363, USA ACD MSP UM JBCB ~120.79'~65.52'~123.91'~37.03'~58.71 '8'-0"42'-9" 33'-8"13'-8"ACD MSP UMCB JBSITE PLAN WITH ROOF PLANREVDATEDESCRIPTIONVERSIONUR07/13/2023INITIAL RELEASESHEET NAMESHEET NUMBERPV-1 PROJECT NAMESHEET SIZEANSI B11" X 17"KARISSA FRENCH 710 S ESTES CT, PORT ANGELES, WA 98363, USA APN# 0630004502400000 UTILITY: PORT ANGELES AHJ: CITY OF PORT ANGELES PROJECT NUMBER: P-0081505 07/22/2023REVISIONASITE PLAN WITHROOF PLAN1SCALE: 1/16" = 1'-0" ROOF ACCESS POINT SHALL BE LOCATED IN AREAS THAT DO NOT REQUIRE THEPLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS WINDOWS ORDOORS, AND LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION INLOCATIONS WHERE THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEADOBSTRUCTIONS SUCH AS TREE LIMBS, WIRES OR SIGNS.NOTE: THE AC DISCONNECT IS LOCATEDWITHIN 10FT OF UTILITY METERNOTE:3/4" OR GREATER EMT CONDUITRUN (7/8" ABOVE ROOF SURFACE)LEGENDAC DISCONNECTJUNCTION BOXACDJBMSPMAIN SERVICE PANELGATEFENCETREESENPHASE IQ COMBINER 4X2-IQ-AM1-240-4 (IEEE 1547:2018)CBUTILITY METERUMVENT, ATTIC FAN (ROOF OBSTRUCTION)PROPERTY LINES ESTES CTEXISTINGDRIVEWAYTWO- STORYHOUSE(E) STRUCTURE ACD MSP UM JBCB4'-1"28'-0"4'-4"10"10'-9"2'-1"REVDATEDESCRIPTIONVERSIONUR07/13/2023INITIAL RELEASESHEET NAMESHEET NUMBERPV-2 PROJECT NAMESHEET SIZEANSI B11" X 17"KARISSA FRENCH 710 S ESTES CT, PORT ANGELES, WA 98363, USA APN# 0630004502400000 UTILITY: PORT ANGELES AHJ: CITY OF PORT ANGELES PROJECT NUMBER: P-0081505 07/22/2023REVISIONAROOF PLAN WITHMODULESROOF PLAN WITH MODULESSCALE: 1/8" = 1'-0"1MODULE TYPE, DIMENSIONS & WEIGHTNUMBER OF MODULES = 16 MODULESMODULE TYPE = HANWHA Q CELLS Q.PEAK DUO BLK ML-G10+ / t(400W) MODULESMODULE WEIGHT = 48.5 LBS / 22.0 KG.MODULE DIMENSIONS = 74.0"X 41.1" = 21.12 SFUNIT WEIGHT OF ARRAY = 2.30 PSFNOTE: ACTUAL ROOF CONDITIONS ANDTRUSSES LOCATIONS MAY VARY. INSTALLPER MANUFACTURER(S) INSTALLATIONGUIDELINES AND ENGINEERED SPANS FORATTACHMENTS· PLUMBING VENTS, SKYLIGHTS AND MECHANICAL VENTS SHALL NOT BE COVERED, MOVED, RE-ROUTED OR RE-LOCATED.NOTE: THE AC DISCONNECT IS LOCATEDWITHIN 10FT OF UTILITY METERNOTE:3/4" OR GREATER EMT CONDUITRUN (7/8" ABOVE ROOF SURFACE)ARRAY AREA & ROOF AREA CALC'SAREA OF NEW ARRAY(Sq. Ft.)AREA OF ROOF(PLANVIEW)(Sq. Ft.)TOTAL ROOF AREACOVERED BY ARRAY %337.931777.5619.01%ARRAY AREA & ROOF AREA CALC'SROOF# OFMODULESARRAYAREA(Sq. Ft.)ROOFAREA(Sq. Ft.)ROOFAREACOVERED BYARRAY (%)#116337.93498.1067.84ROOF DESCRIPTIONROOF TYPEASPHALT SHINGLESROOFROOFROOFTILTAZIMUTHTRUSSESSIZETRUSSESSPACING#130°182°2"x4"24" O.C.LEGENDVENT, ATTIC FAN(ROOF OBSTRUCTION)ROOF ATTACHMENT UNIRAC STRONGHOLDBUTYL @ 48" O.C.TRUSSESAC DISCONNECTJUNCTION BOXACDJBMSPMAIN SERVICE PANELFIRE PATHWAYUNIRAC NXT UMOUNT RAILENPHASE ENERGY IQ8PLUS-72-2-USMICRO-INVERTERSENPHASE IQ COMBINER 4X2-IQ-AM1-240-4 (IEEE 1547:2018)CBUTILITY METERUMBILL OF MATERIALSEQUIPMENTQTYDESCRIPTIONRAIL08UNIRAC NXT UMOUNT RAIL 168" DRKRAIL SPLICE04NXT UMOUNT RAIL SPLICEUNIVERSAL CLAMP36NXT UMOUNT COMBO CLAMP DRKROOFATTACHMENTS32UNIRAC STRONGHOLD BUTYLACCESSORIES08NXT UMOUNT RL & CLMP CAP KITMLPE & GROUNDING18NXT UMOUNT MLPE & LUG CLAMPROOF #118" FIRE PATHWAY18" FIRE PATHWAY36" FIRE PATHWAY 36" FIRE PATHWAY 18" FIRE PATHWAY18" FIRE PATHWAY36" FIRE PATHWAY S ESTES CTFRONT YARDREAR YARD REVDATEDESCRIPTIONVERSIONUR07/13/2023INITIAL RELEASESHEET NAMESHEET NUMBERPV-3 PROJECT NAMESHEET SIZEANSI B11" X 17"KARISSA FRENCH 710 S ESTES CT, PORT ANGELES, WA 98363, USA APN# 0630004502400000 UTILITY: PORT ANGELES AHJ: CITY OF PORT ANGELES PROJECT NUMBER: P-0081505 07/22/2023REVISIONAATTACHMENTDETAILATTACHMENT DETAILSCALE: NTS1ATTACHMENT DETAIL (ENLARGED VIEW)SCALE: NTS2NOTE: ACTUAL ROOF CONDITIONS AND TRUSSES (OR SEAM)LOCATIONS MAY VARY. INSTALL PER MANUFACTURER(S)INSTALLATION GUIDELINES AND ENGINEERED SPANS FORATTACHMENTS(E ) 2"X4 " TRUSSES @ 24" O .CENLARGE VIEW(N) PV MODULES(E) ASPHALT SHINGLES ROOF(N) NXT UMOUNT COMBO CLAMP(N) PV MODULES(N) NXT UMOUNT RAIL(N) NXT UMOUNT RAIL CLAMP ASSY(E) ROOF / DECK MEMBRANE(E) ASPHALT SHINGLES ROOF5/16"-18 x 2"SERRATED FLANGE HEX SCREW~4"~4"4X12-14 SCREW, HWH, SS, SELF-DRW/ #12 EPDM WASHER1-3/4" MIN.EMBEDMENT1.26"1.26"(N) STRONGHOLD ATT W/BUTYL, MILL(N) DTD BUTYL ATT ASSY (1/8" BUTYL) REVDATEDESCRIPTIONVERSIONUR07/13/2023INITIAL RELEASESHEET NAMESHEET NUMBERPV-4 PROJECT NAMESHEET SIZEANSI B11" X 17"KARISSA FRENCH 710 S ESTES CT, PORT ANGELES, WA 98363, USA APN# 0630004502400000 UTILITY: PORT ANGELES AHJ: CITY OF PORT ANGELES PROJECT NUMBER: P-0081505 07/22/2023REVISIONAELECTRICAL LINEDIAGRAM &CALCULATIONELECTRICAL LINE DIAGRAM WITH CALCULATIONSCALE: NTS1L200AEXISTINGGROUNDINGSYSTEM(E) MAIN BREAKER200A/2P, 240V25A/2P(N) 25A/2P PVBREAKER(E) MAINSERVICE PANEL,200A RATED,120/240VBI-DIRECTIONALUTILITY METER1-PHASE, 3-W,120V/240V, 60HzG(N) 30A NON FUSEDVISIBLE, LOCKABLE,LABELLED HEAVY DUTYAC DISCONNECT, 240 VACNNL2L1L2L1AC DISCONNECT SHALL BE LOCATEDWITHIN 10' OF UTILITY METERINTERCONNECTION120% RULE - NEC 705.12(b)(3)(2)UTILITY FEED + SOLAR BACKFEED200A +25A = 225ABUSS RATING x 120%200A x 120% = 240ACSOLAR MODULE SPECIFICATIONSMANUFACTURER / MODEL #VMPIMPVOCISCTEMPERATURECOEFFICIENTOF Voc# OFMODULESHANWHA Q CELLS Q.PEAK DUOBLK ML-G10+ / t (400W)38.0910.5045.5511.07-0.27%/K16MODULE DIMENSION74.0" L x 41.1" W x 1.26" DNOTE: THE AC DISCONNECT IS LOCATEDWITHIN 10FT OF UTILITY METER·GAS METER LOCATED IN PROXIMITY OF THE PV INSTALLATION, LOAD CENTER, AND/ORDISCONNECTS. DISCONNECTS SHALL BE LOCATED IN COMPLIANCE WITH UTILITY AND THE AHJ(AUTHORITY HAVING JURISDICTION). PV INSTALLATION SHALL COMPLY WITH ALL APPLICABLECODES.·WIRE RATED AND AMPACITY CALCULATED @ 90°C FOR ROOFTOP INSTALLATION AND ATTIC RUNTO INVERTER.·PER NEC REQUIRMENTS GROUNDING CONDUCTORS SMALLER THAN 6AWG SHALL BEPROTECTED IN A CONDUIT, RACEWAY, OR ARMORED PROTECTIVE SHEATHING (NEC 250.64).·THE WORKING CLEARANCES AROUND THE EXISTING ELECTRICAL EQUIPMENT AS WELL AS THENEW ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN ACCORDANCE WITH NEC 110.26.·ANY CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT. (NEC300.6 C1, 310.8 D).·ROOM FOR EQUIPMENT WITHIN 5 FEET FROM MSP.·ALL CONDUIT SHALL BE EMT 3/4" IN DIAMETER UNLESS OTHERWISE STATED.·CONFIGURE FOR IEEE 1547 ANTI-ISLANDING GRID PROFILEUTILITY PROVIDER:MAIN SERVICE VOLTAGE:MAIN PANEL BRAND:MAIN SERVICE PANEL:MAIN CIRCUIT BREAKER RATING:MAIN SERVICE LOCATION:SERVICE FEED SOURCE:PORT ANGELES240VSQUARE D(E) 200A(E) 200AEASTSERVICE INFO.UNDERGROUNDNOTE:3/4" OR GREATER EMT CONDUITRUN (7/8" ABOVE ROOF SURFACE)SYSTEM SIZE:- 16 x 400W = 6.400 kWDC 16 x 290VA = 4.640 kWACINVERTER SPECIFICATIONSMANUFACTURER / MODEL #QUANTITYNOMINAL OUTPUTVOLTAGENOMINAL OUTPUTCURRENTENPHASE ENERGYIQ8PLUS-72-2-US16240 VAC1.21AWire TagConduitWire QtyWireGaugeWire TypeTemp.RatingWireAmpacity (A)Temp.DerateConduitFill DerateDeratedAmpacity (A)InverterQtyNOC (A)NECCorrectionDesignCurrent (A)GroundSizeGround WireTypeAOPEN AIR212 AWGQ CABLE90°C301.04N/A31.20081.211.2512.1006 AWGBARE CUB3/4" EMT412 AWGTHWN-290°C301.040.8024.96081.211.2512.1006 AWGTHWN-2C3/4" EMT36 AWGTHWN-290°C751.041.078.00161.211.2524.2006 AWGTHWN-2(16) ENPHASE ENERGYIQ8PLUS-72-2-USMICRO-INVERTERS (240V)(LOCATED UNDER EACH PANEL)(N) JUNCTION BOX08 MICRO-INVERTERS IN BRANCH #2GL1L1L2L2N20AGBRANCH TERMINATOR Q-TERMFOR IQ SERIES (TYP.)10A/15A20A08 MICRO-INVERTERS IN BRANCH #1L1L1L2L2AB(N) ENPHASE IQCOMBINER BOX 4X2-IQ-AM1-240-4(IEEE1547:2018) [240V]M*IQ-GATEWAYAMBIENT TEMPERATURE SPECIFICATIONSRECORDLOW TEMPAMBIENT TEMP(HIGH TEMP 2%)CONDUCTORTEMPERATURERATE-6°25°90°NOTE-WIRE AMPACITY AND EQUIPMENTRATED AT 75 DEGREESA REVDATEDESCRIPTIONVERSIONUR07/13/2023INITIAL RELEASESHEET NAMESHEET NUMBERPV-5 PROJECT NAMESHEET SIZEANSI B11" X 17"KARISSA FRENCH 710 S ESTES CT, PORT ANGELES, WA 98363, USA APN# 0630004502400000 UTILITY: PORT ANGELES AHJ: CITY OF PORT ANGELES PROJECT NUMBER: P-0081505 07/22/2023REVISIONAWARNING LABELS &PLACARDPOWER TO THIS BUILDING IS ALSO SUPPLIED FROM THEFOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN710 S ESTES CT (N) PV MODULESCAUTION !MULTIPLE SOURCES OF POWER WARNING DUAL POWER SOURCESECOND SOURCE IS PHOTOVOLTAIC SYSTEMLABEL LOCATION:EMT/CONDUIT RACEWAYS(PER CODE: NEC690.31(D)(2)PHOTOVOLTAIC POWER SOURCELABEL LOCATION:POINT OF INTERCONNECTIONPRODUCTION METERNEC 705.12(D)(3) & NEC 690.59)NOTES AND SPECIFICATIONS:·SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE2020 ARTICLE 110.21(B), UNLESS SPECIFIC INSTRUCTIONSARE REQUIRED BY SECTION 690, OR IF REQUESTED BY THELOCAL AHJ.·SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDSUSING EFFECTIVE WORDS, COLORS AND SYMBOLS.·LABELS SHALL BE PERMANENTLY AFFIXED TO THEEQUIPMENT OR WIRING METHOD AND SHALL NOT BE HANDWRITTEN.·LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTANDTHE ENVIRONMENT INVOLVED.·SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011,PRODUCT SAFETY SIGNS AND LABELS, UNLESS OTHERWISESPECIFIED.·DO NOT COVER EXISTING MANUFACTURER LABELS.ELECTRICAL SHOCK HAZARDWARNINGTERMINALS ON LINE AND LOADSIDES MAY BE ENERGIZED INTHE OPEN POSITIONLABEL LOCATION:INVERTER(S), AC DISCONNECT(S), ACCOMBINER PANEL (IF APPLICABLE).PER CODE(S): NEC 2020: NEC 690.13(B)& NEC 690.15(C)MAXIMUM AC OPERATING CURRENT:NOMINAL OPERATING AC VOLTAGE: 19.36 AMPS 240 VACLABEL LOCATION:KNIFE SWITCH(S), PHOTOVOLTAIC SYSTEM POINT OFINTERCONNECTION.PER CODE(S): NEC 2020: 690.54SOLAR PV SYSTEM EQUIPPEDWITH RAPID SHUTDOWNSOLAR ELECTRICPV PANELSTURN RAPID SHUTDOWNSWITCH TO THE "OFF"POSITION TO SHUT DOWNPV SYSTEM AND REDUCESHOCK HAZARD IN THEARRAY.LABEL LOCATION:MAIN SERVICE PANEL.PER CODE(S): NEC 2020: IFC 605.11.3.1(1) & 690.56(C)!3"3"PHOTOVOLTAIC KNIFE SWITCHMAIN PHOTOVOLTAICSYSTEM DISCONNECTLABEL LOCATION:MAIN SERVICE DISCONNECT / UTILITY METER(PER CODE: NEC 690.13(B))LABEL LOCATION:UTILITY SERVICE ENTRANCE/METER, INVERTER/DCDISCONNECT IF REQUIRED BY LOCAL AHJ, OROTHER LOCATIONS AS REQUIRED BY LOCAL AHJ.PER CODE(S): NEC 2020: 690.56(C)(2) WITH IN 3 FEETRAPID SHUTDOWN SWITCHFOR SOLAR PV SYSTEM!WARNINGTHE DISCONNECTION OF THEGROUNDED CONDUCTOR(S)MAY RESULT IN OVERVOLTAGEON THE EQUIPMENT!LABEL LOCATION:COMBINER BOXPER CODE: NEC 690.31(E)THIS EQUIPMENT FED BYMULTIPLE SOURCES:TOTAL RATING OF ALL OVERCURRENTDEVICES EXCLUDING MAIN POWERSUPPLY SHALL NOT EXCEEDAMPACITY OF BUSBARWARNINGLABEL LOCATION: POINTS OF CONNECTION/BREAKERCODE: NEC 705.12(B)(3)(3)WARNINGPOWER SOURCE OUTPUTCONNECTIONDO NOT RELOCATE THISOVERCURRENT DEVICE!LABEL LOCATION:SERVICE PANEL IF SUM OF BREAKERS EXCEEDSPANEL RATINGNEC 705.12 (B)(3)(2)!LABEL LOCATION:MSP (PER CODE: NEC 705.12(D)(2) &NEC 690.59CAUTIONPHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFED!PHOTOVOLTAICAC DISCONNECTLABEL LOCATION:AC DISCONNECTNEC 690.13(B)(N) 30A NON FUSEDAC DISCONNECT(N) ENPHASE IQCOMBINER BOX 4(E) UTILITY METER(E) 200A MAIN SERVICE PANELWITH (E) 200A MAIN BREAKER REVDATEDESCRIPTIONVERSIONUR07/13/2023INITIAL RELEASESHEET NAMESHEET NUMBERPV-6 PROJECT NAMESHEET SIZEANSI B11" X 17"KARISSA FRENCH 710 S ESTES CT, PORT ANGELES, WA 98363, USA APN# 0630004502400000 UTILITY: PORT ANGELES AHJ: CITY OF PORT ANGELES PROJECT NUMBER: P-0081505 07/22/2023REVISIONASPEC SHEETS REVDATEDESCRIPTIONVERSIONUR07/13/2023INITIAL RELEASESHEET NAMESHEET NUMBERPV-7 PROJECT NAMESHEET SIZEANSI B11" X 17"KARISSA FRENCH 710 S ESTES CT, PORT ANGELES, WA 98363, USA APN# 0630004502400000 UTILITY: PORT ANGELES AHJ: CITY OF PORT ANGELES PROJECT NUMBER: P-0081505 07/22/2023REVISIONASPEC SHEETS REVDATEDESCRIPTIONVERSIONUR07/13/2023INITIAL RELEASESHEET NAMESHEET NUMBERPV-8 PROJECT NAMESHEET SIZEANSI B11" X 17"KARISSA FRENCH 710 S ESTES CT, PORT ANGELES, WA 98363, USA APN# 0630004502400000 UTILITY: PORT ANGELES AHJ: CITY OF PORT ANGELES PROJECT NUMBER: P-0081505 07/22/2023REVISIONASPEC SHEETS REVDATEDESCRIPTIONVERSIONUR07/13/2023INITIAL RELEASESHEET NAMESHEET NUMBERPV-9 PROJECT NAMESHEET SIZEANSI B11" X 17"KARISSA FRENCH 710 S ESTES CT, PORT ANGELES, WA 98363, USA APN# 0630004502400000 UTILITY: PORT ANGELES AHJ: CITY OF PORT ANGELES PROJECT NUMBER: P-0081505 07/22/2023REVISIONASPEC SHEETS REVDATEDESCRIPTIONVERSIONUR07/13/2023INITIAL RELEASESHEET NAMESHEET NUMBERPV-10 PROJECT NAMESHEET SIZEANSI B11" X 17"KARISSA FRENCH 710 S ESTES CT, PORT ANGELES, WA 98363, USA APN# 0630004502400000 UTILITY: PORT ANGELES AHJ: CITY OF PORT ANGELES PROJECT NUMBER: P-0081505 07/22/2023REVISIONASPEC SHEETS REVDATEDESCRIPTIONVERSIONUR07/13/2023INITIAL RELEASESHEET NAMESHEET NUMBERPV-11 PROJECT NAMESHEET SIZEANSI B11" X 17"KARISSA FRENCH 710 S ESTES CT, PORT ANGELES, WA 98363, USA APN# 0630004502400000 UTILITY: PORT ANGELES AHJ: CITY OF PORT ANGELES PROJECT NUMBER: P-0081505 07/22/2023REVISIONASPEC SHEETS REVDATEDESCRIPTIONVERSIONUR07/13/2023INITIAL RELEASESHEET NAMESHEET NUMBERPV-12 PROJECT NAMESHEET SIZEANSI B11" X 17"KARISSA FRENCH 710 S ESTES CT, PORT ANGELES, WA 98363, USA APN# 0630004502400000 UTILITY: PORT ANGELES AHJ: CITY OF PORT ANGELES PROJECT NUMBER: P-0081505 07/22/2023REVISIONASPEC SHEETS REVDATEDESCRIPTIONVERSIONUR07/13/2023INITIAL RELEASESHEET NAMESHEET NUMBERPV-13 PROJECT NAMESHEET SIZEANSI B11" X 17"KARISSA FRENCH 710 S ESTES CT, PORT ANGELES, WA 98363, USA APN# 0630004502400000 UTILITY: PORT ANGELES AHJ: CITY OF PORT ANGELES PROJECT NUMBER: P-0081505 07/22/2023REVISIONASPEC SHEETS REVDATEDESCRIPTIONVERSIONUR07/13/2023INITIAL RELEASESHEET NAMESHEET NUMBERPV-14 PROJECT NAMESHEET SIZEANSI B11" X 17"KARISSA FRENCH 710 S ESTES CT, PORT ANGELES, WA 98363, USA APN# 0630004502400000 UTILITY: PORT ANGELES AHJ: CITY OF PORT ANGELES PROJECT NUMBER: P-0081505 07/22/2023REVISIONASPEC SHEETS REVDATEDESCRIPTIONVERSIONUR07/13/2023INITIAL RELEASESHEET NAMESHEET NUMBERPV-15 PROJECT NAMESHEET SIZEANSI B11" X 17"KARISSA FRENCH 710 S ESTES CT, PORT ANGELES, WA 98363, USA APN# 0630004502400000 UTILITY: PORT ANGELES AHJ: CITY OF PORT ANGELES PROJECT NUMBER: P-0081505 07/22/2023REVISIONASPEC SHEETS REVDATEDESCRIPTIONVERSIONUR07/13/2023INITIAL RELEASESHEET NAMESHEET NUMBERPV-16 PROJECT NAMESHEET SIZEANSI B11" X 17"KARISSA FRENCH 710 S ESTES CT, PORT ANGELES, WA 98363, USA APN# 0630004502400000 UTILITY: PORT ANGELES AHJ: CITY OF PORT ANGELES PROJECT NUMBER: P-0081505 07/22/2023REVISIONASPEC SHEETS PREPARED 7/26/23,14:22:20 PAYMENT DUE CITY OF PORT ANGELES PROGRAM BP820L --------------------------------------------------------------------------- APPLICATION NUMBER:23-00000799 710 ESTES CT FEE DESCRIPTION AMOUNT DUE --------------------------------------------------------------------------- ELECTRICAL ALTER RESIDENTIAL 120.00 TOTAL DUE 120.00 Please present reciept to the cashier with full payment ELECTRICAL INSPECTION WIRING REPORT APPROVED NOT APPROVED DITCH ROUGH IN/COVER SERVICE FINAL COMMENTS NOTIFY INSPECTOR at (360) 808-2613 WHEN CORRECTIONS ARE COMPLETED WITHIN 15 DAYS DATE PERMIT # INSPECTOR 8/29/2023 23-799 TAP OWNER CONTRACTOR Lumio PROJECT ADDRESS 710 Estes Ct