Loading...
HomeMy WebLinkAbout1723 Lambert Ln - Building . CITY OF PORT ANGELES LIGHT DEPARTMENT 321 E. Fifth Street Port Angeles, WA 98362 (206) 457-0411 ELECTRICAL PERMIT Site Address: ~ o READY FOR INSPECTION License Number: o WILL CALL FOR INSPECTION Phone: Installed By: Owner/Business: Owner/Business Address: ELECTRIC HEAT o BASEBOARD KW _ o FURNACE KW ~ HEAT PUMP KW y- O FAN/WALL KW _ o RESIDENTIAL o COMMERCIAL o NEW CONSTRUCTION o REMODEL ~ ADD/ALTER CIRCUITS o SERVICE UPGRADE/REPAIR o TEMPORARY SERVICE Details/Description: A~~ ,~;(/W /AJ,I?~. . I~ {L <2-r;; fJ PERMIT NO. "YJ?C ~ DATE / I ~ 7/7',</ Phone: Sq. Ft. o RISER o OVERHEAD SERVICE o UNDERGROUND SERVICE VOLTAGE: 01~ 03~ SERVICE SIZE FEEDER SIZE AMPS AMPS W.S. No. SERVICE SIZE CAPACITY: o O.K. 0 NOT O.K. ACTION REQUIRED: 0 CHANGE TRANSFORMER o INSTALL SERVICE POLE DATE ENGR. o OVERHEAD SERVICE APPROVED o CHANGE SERVICE WIRE o OTHER o Ditch Inspection O.K. o Rough-in/cover O.K. o O.K. to connect service I\r^~Final O.K. ~ Permit/Receipt No. I/o t "3 New Meters . Notify Port Ange s City Light by Street Address and Permit Number when ready for inspection. Work must not be covered before inspection and O.K. for covering has been given by the electrical inspector in writing on either the Wiring Report or on the Building Permil. PHONE 457-0411, EXT. 224. ,# ~ NO OCCUPANCY OR USE ESTABLISHED UNDER THIS PERMIT $ (f 3 0 Electrical Inspector WHITE - File by address PINK - Top: Eng, Bottom, Customer OLYMPICPRINTERSINC Permit Fee GREEN - Top: Meier Dept., Bottom: City Hall Application Number . . . . . 23-00001082 Date 10/10/23 Application pin number . . . 363536 Property Address . . . . . . 1723 LAMBERT LN ASSESSOR PARCEL NUMBER: 06-30-14-6-5-0080-0000- Application type description ELECTRICAL ONLY Subdivision Name . . . . . . Property Use . . . . . . . . Property Zoning . . . . . . . RESIDENTIAL HIGH DENSITY Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc PV system ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ BOBBY D AND CAROL L DUNLAP LUMIO HX, INC 1723 LAMBERT LN 1550 W DIGITAL DR PORT ANGELES WA 983624967 LEHI UT 84043 (360) 637-4343 ---------------------------------------------------------------------------- Permit . . . . . . ELECTRICAL ALTER RESIDENTIAL Additional desc . . Permit Fee . . . . 120.00 Plan Check Fee . . .00 Issue Date . . . . 10/10/23 Valuation . . . . 0 Expiration Date . . 4/07/24 Qty Unit Charge Per Extension 1.00 120.0000 ECH EL-0-200 SRV FEEDER 120.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 120.00 120.00 .00 .00 Plan Check Total .00 .00 .00 .00 Grand Total 120.00 120.00 .00 .00 Public Works and Utilities Department 321 E. 5th Street, Port Angeles, WA 98362 360.417.4735 | www.cityofpa.us | electricalpermits@cityofpa.us EL1-2 SF 1 - 2 SINGLE-FAMILY ELECTRICAL PERMIT APPLICATION Project Address: Project Description: Single-Family Residential Duplex / ARU Building Square footage: OWNER INFORMATION Name: Email: Mailing Address: Phone: ELECTRICAL CONTRACTOR INFORMATION Name: License: Mailing Address: Expiration Date: Email: Phone: PROJECT DETAILS Item Unit Charge Quantity Total (Quantity x Unit Charge) Service/Feeder 200 Amp. $120.00 $ Service/Feeder 201-400 Amp. $146.00 $ Service/Feeder 401-600 Amp. $205.00 $ Service/Feeder 601-1000 Amp. $262.00 $ Service/Feeder over 1000 Amp. $373.00 $ Branch Circuit W/ Service Feeder $5.00 $ Branch Circuit W/O Service Feeder $63.00 $ Each Additional Branch Circuit $5.00 $ Branch Circuits 1-4 $75.00 $ Temp. Service/Feeder 200 Amp. $93.00 $ Temp. Service/Feeder 201-400 Amp. $110.00 $ Temp. Service/Feeder 401-600 Amp. $149.00 $ Temp. Service/Feeder 601-1000 Amp. $168.00 $ Portal to Portal Hourly $96.00 $ Signal Circuit/Limited Energy - 1&2 DU. $64.00 $ Manufactured Home Connection $120.00 $ Renewable Elec. Energy: 5KVA System or less $102.00 $ Thermostat (Note: $5 for each additional) $56.00 $ First 1300 Square Feet $120.00 $ Each Additional 500 square feet`` $40.00 $ Each Outbuilding / Detached Garage $74.00 $ Each Swimming Pool / Hot Tub $110.00 $ TOTAL $ required to hire an electrical contractor if above said property is for sale, rent or lease. Permit expires after six months of last inspection. After reading the above statement, I hereby certify that I am the owner of the above named property or a licensed electrical contractor. I am making the electrical installation or alteration in compliance with the electrical laws, N.E.C., RCW. Chapter 19.28, WAC. Chapter 296- Date Print Name Signature (Owner Electrical Contractor / Administrator) New Construction Only [Electrical Permit Applications may be submitted to City Hall or electricalpermits@cityofpa.us or faxed to 360.417.4711] PREPARED 10/09/23,10:43:34 PAYMENT DUE CITY OF PORT ANGELES PROGRAM BP820L --------------------------------------------------------------------------- APPLICATION NUMBER:23-00001082 1723 LAMBERT LN FEE DESCRIPTION AMOUNT DUE --------------------------------------------------------------------------- ELECTRICAL ALTER RESIDENTIAL 120.00 TOTAL DUE 120.00 Please present reciept to the cashier with full payment COVER SHEETPHOTOVOLTAIC ROOF MOUNT SYSTEM1723 E LAMBERT LN, PORT ANGELES, WA 98362, USAREVDATEDESCRIPTIONVERSIONUR09/06/2023INITIAL RELEASESHEET NAMESHEET NUMBERPV-0 PROJECT NAMESHEET SIZEANSI B11" X 17"BOBBY DUNLAP 1723 E LAMBERT LN, PORT ANGELES, WA 98362, USA APN# 0630146500800000 UTILITY: CITY OF PORT ANGELES AHJ: CITY OF PORT ANGELES PROJECT NUMBER: P-0086434 22 MODULES-ROOF MOUNTED - 8.800 kWDC, 6.380 kWACGOVERNING CODES:2020 NATIONAL ELECTRICAL CODE (NEC)2018 INTERNATIONAL BUILDING CODE2018 INTERNATIONAL EXISTING BUILDING CODE2018 INTERNATIONAL SWIMMING POOL AND SPA CODE2018 INTERNATIONAL FIRE CODE2018 WASHINGTON STATE ENERGY CODE2018 INTERNATIONAL RESIDENTIAL CODE2018 INTERNATIONAL MECHANICAL CODE2018 UNIFORM PLUMBING CODE2VICINITY MAPSCALE: NTSPV-01AERIAL PHOTOSCALE: NTSPV-0SHEET INDEXPV-0COVER SHEETPV-1SITE PLAN WITH ROOF PLANPV-2ROOF PLAN WITH MODULESPV-3ATTACHMENT DETAILSPV-4 ELECTRICAL LINE DIAGRAM WITHCALCULATIONPV-5 WARNING LABELS & PLACARDPV-6 SAFETY PLANPV-7+EQUIPMENT SPEC SHEETSNOTES:1.PHOTOVOLTAIC SYSTEM EQUIPMENT SHALL BE INSTALLED INACCORDANCE WITH NEC 2020 ARTICLES 690 AND 705, AND THE 2018IRC/IBC & 2018 INTERNATIONAL FIRE CODE, AND APPLICABLEREQUIREMENTS OF THE SERVICE UTILITY AND AUTHORITY HAVINGJURISDICTION. PHOTOVOLTAIC SYSTEM EQUIPMENT WILL BE POSTEDWITH APPLICABLE WARNINGS, SIGNAGE AND PLAQUES PER NEC 690.13,705.10 AND 706.15.2.PHOTOVOLTAIC SOURCE AND OUTPUT CIRCUITS SHALL COMPLY WITHTHE WIRING METHODS AND INSTALLATION AND MARKINGREQUIREMENTS OF NEC 690.31(D).3.BREAKER LABELED "PHOTOVOLTAIC ELECTRIC POWER SOURCE" AND"BREAKERS ARE BACK FED" PER NEC 705.12(D) & NEC 690.59. BREAKERALSO LABELED "MAXIMUM AC OUTPUT CURRENT AND OPERATING ACVOLTAGE" PER NEC 690.54. BREAKER SHALL BE POSITIONED AT THEOPPOSITE (LOAD) END FROM THE INPUT FEEDER OR MAIN CIRCUITBREAKER LOCATION, AND LABELED "WARNING INVERTER OUTPUTCONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE", PERNEC 705.12 (B)(3)(2).4.WARNING SIGN PER NEC 706.15(C)(4) and NEC 690.13(B) READING"WARNING - ELECTRIC SHOCK HAZARD - TERMINALS ON BOTH LINE ANDLOAD SIDES MAY BE ENERGIZED IN THE OFF POSITION."5.LABEL "PHOTOVOLTAIC SYSTEM UTILITY DISCONNECT SWITCH." SWITCHTO BE LOCKED PER NEC 690.13(B). SWITCH TO BE VISIBLE BLADEDISCONNECT PER UTILITY REQUIREMENTS AND CONFORM TO NEC705.22.6.LABEL "PHOTOVOLTAIC ARRAY DC DISCONNECT SWITCH" PER NEC690.13(B). LABEL WITH OPERATING CURRENT, OPERATING VOLTAGE,MAXIMUM SYSTEM VOLTAGE, AND SHORT CIRCUIT CURRENT PER NEC690.53. SWITCH LOCKED PER NEC 690.13(B).7.LISTING AGENCY NAMES AND NUMBERS TO BE INDICATED ON POWERINVERTER(S) AND SOLAR MODULES PER NEC 110.3 (B).8.LABELED PHOTOVOLTAIC SYSTEM DEDICATED KWH METER. (NOT USED)9.BI-DIRECTIONAL METER TO BE INSTALLED BY UTILITY.10.DEDICATED PHOTOVOLTAIC COMBINER SUB-PANEL. LABEL "LOADS NOTTO BE ADDED TO THIS PANEL."11.ALL LABELS EXPOSED TO SUNLIGHT MUST BE ENGRAVED ANDATTACHED PER APPROVED METHOD.12.LABEL "BREAKER HAS BEEN DE-RATED PER NEC 705.12(D)(2)." NO NEWLOADS.13.EXISTING EQUIPMENT IS NOTED WITH A DASHED LINE. SOLID LINESDENOTE EQUIPMENT INSTALLED BY ELECTRICAL CONTRACTOR.14.WIRE MAY BE RUN SHORT DISTANCES OUTSIDE OF CONDUIT IF WIREREADS "SUNLIGHT RESISTANT."15.THE GROUNDING ELECTRODE CONDUCTOR SHALL BE CONTINUOUS ANDTERMINATE WITH AN IRREVERSIBLE CONNECTION TO THE ACGROUNDING ELECTRODE SYSTEM PER NEC 250.64(B).16.AMBIENT TEMPERATURE ADJUSTED FOR CONDUITS EXPOSED TOSUNLIGHT ON OR ABOVE ROOFTOPS PER TABLE 310.15 (B)(2). CONDUITELEVATED MIN. 1/2"; ADDER 33 DEG F.17.ALL EXTERIOR EQUIPMENT TO BE NEMA 3R.18.THE PHOTOVOLTAIC POWER SOURCE SHALL BE LABELED WITH THEFOLLOWING WARNING AT EACH JUNCTION BOX, COMBINER BOX,DISCONNECT AND DEVICE WHERE ENERGIZED, UNGROUNDED CIRCUITSMAY BE EXPOSED DURING SERVICE: WARNING: ELECTRIC SHOCK HAZARD. THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZEDSYSTEM SUMMARY:(N) 22 - HANWHA Q CELLS Q.PEAK DUO BLK ML-G10+ / t (400W) MODULES(N) 22 - ENPHASE ENERGY IQ8PLUS-72-2-US MICRO-INVERTERS [240V](N) JUNCTION BOX(E) 200A MAIN SERVICE PANEL WITH (E) 200A MAIN BREAKER(N) ENPHASE IQ COMBINER BOX 4 [240V]X2-IQ-AM1-240-4 (IEEE 1547:2018)(N) 60A NON-FUSED AC DISCONNECT [240V]ROOF TYPE: - ASPHALT SHINGLESNUMBER OF LAYERS: - 01ROOF FRAME: - 2"X4" TRUSSES @ 24" O.C.STORY: - ONE STORYSNOW LOAD : - 25 PSFWIND SPEED :- 110 MPHWIND EXPOSURE:- CRISK CATEGORY:- IICOORDINATE:- 48.101135, -123.406254DESIGN CRITERIA:UTILITY METER NO: E52519 ~120.31'~45.08'~47.67'~2 3 . 0 6 '~31.83'~76.09' 17'-7"13'-8"42'-10"2'-6"JBMSPUMACDCB MSPUMACDCB JBSITE PLAN WITH ROOF PLANREVDATEDESCRIPTIONVERSIONUR09/06/2023INITIAL RELEASESHEET NAMESHEET NUMBERPV-1 PROJECT NAMESHEET SIZEANSI B11" X 17"BOBBY DUNLAP 1723 E LAMBERT LN, PORT ANGELES, WA 98362, USA APN# 0630146500800000 UTILITY: CITY OF PORT ANGELES AHJ: CITY OF PORT ANGELES PROJECT NUMBER: P-0086434SITE PLAN WITHROOF PLAN1SCALE: 1/16" = 1'-0" ROOF ACCESS POINT SHALL BE LOCATED IN AREAS THAT DO NOT REQUIRE THEPLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS WINDOWS ORDOORS, AND LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION INLOCATIONS WHERE THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEADOBSTRUCTIONS SUCH AS TREE LIMBS, WIRES OR SIGNS.NOTE: THE AC DISCONNECT IS LOCATEDWITHIN 10FT OF UTILITY METERNOTE:3/4" OR GREATER EMT CONDUITRUN (7/8" ABOVE ROOF SURFACE)LEGENDAC DISCONNECTJUNCTION BOXACDJBMSPMAIN SERVICE PANELTREEENPHASE IQ COMBINER BOX 4X2-IQ-AM1-240-4 (IEEE 1547:2018)CBUTILITY METERUMVENT, ATTIC FAN (ROOF OBSTRUCTION)PROPERTY LINEE LAMBERT LNS CUR R I E R C T NOTE: THERE IS NO FENCE OR GATE IN THIS PROPERTYEXISTINGDRIVE W A Y ONE- STO R Y HOUS E 10'-7" 20'-9" 3'-4" 17'-4" 8'-7"8"16'-8"3'-7"JBMSPUMACDCB REVDATEDESCRIPTIONVERSIONUR09/06/2023INITIAL RELEASESHEET NAMESHEET NUMBERPV-2 PROJECT NAMESHEET SIZEANSI B11" X 17"BOBBY DUNLAP 1723 E LAMBERT LN, PORT ANGELES, WA 98362, USA APN# 0630146500800000 UTILITY: CITY OF PORT ANGELES AHJ: CITY OF PORT ANGELES PROJECT NUMBER: P-0086434ROOF PLAN WITHMODULESROOF PLAN WITH MODULESSCALE: 1/8" = 1'-0"1MODULE TYPE, DIMENSIONS & WEIGHTNUMBER OF MODULES = 22 MODULESMODULE TYPE = HANWHA Q CELLS Q.PEAK DUO BLK ML-G10+ / t(400W) MODULESMODULE WEIGHT = 48.5 LBS / 22.0 KG.MODULE DIMENSIONS = 74.0"X 41.1" = 21.12 SFUNIT WEIGHT OF ARRAY = 2.30 PSFNOTE: ACTUAL ROOF CONDITIONS ANDTRUSSES LOCATIONS MAY VARY. INSTALLPER MANUFACTURER(S) INSTALLATIONGUIDELINES AND ENGINEERED SPANS FORATTACHMENTS· PLUMBING VENTS, SKYLIGHTS AND MECHANICAL VENTS SHALL NOT BE COVERED, MOVED, RE-ROUTED OR RE-LOCATED.NOTE: THE AC DISCONNECT IS LOCATEDWITHIN 10FT OF UTILITY METERNOTE:3/4" OR GREATER EMT CONDUITRUN (7/8" ABOVE ROOF SURFACE)ARRAY AREA & ROOF AREA CALC'SAREA OF NEW ARRAY(Sq. Ft.)AREA OF ROOF(PLANVIEW)(Sq. Ft.)TOTAL ROOF AREACOVERED BY ARRAY %464.66302015.39%ARRAY AREA & ROOF AREA CALC'SROOF# OFMODULESARRAYAREA(Sq. Ft.)ROOFAREA(Sq. Ft.)ROOFAREACOVERED BYARRAY (%)#118380.18764.1349.75#20484.48321.5426.27ROOF DESCRIPTIONROOF TYPEASPHALT SHINGLESROOFROOFROOFTILTAZIMUTHTRUSSESSIZETRUSSESSPACING#126°103°2"x4"24" O.C.#226°193°2"x4"24" O.C.LEGENDVENT, ATTIC FAN(ROOF OBSTRUCTION)ROOF ATTACHMENT UNIRAC STRONGHOLDBUTYL @ 48" O.C.TRUSSESAC DISCONNECTJUNCTION BOXACDJBMSPMAIN SERVICE PANELFIRE PATHWAYUNIRAC NXT UMOUNT RAILENPHASE ENERGY IQ8PLUS-72-2-USMICRO-INVERTERSENPHASE IQ COMBINER BOX 4X2-IQ-AM1-240-4 (IEEE 1547:2018)CBUTILITY METERUMBILL OF MATERIALSEQUIPMENTQTYDESCRIPTIONRAIL11UNIRAC NXT UMOUNT RAIL 168" DRKRAIL SPLICE6NXT UMOUNT RAIL SPLICEUNIVERSAL CLAMP60NXT UMOUNT COMBO CLAMP DRKROOFATTACHMENTS55UNIRAC STRONGHOLD BUTYLACCESSORIES32NXT UMOUNT RL & CLMP CAP KITMLPE & GROUNDING30NXT UMOUNT MLPE & LUG CLAMPE LAMBERT LNFRONT YARDREAR YARDS CUR R I E R C T ROOF # 1ROOF #218" FIRE PATHWAY18" FIRE PATHWAY18" FIRE PATHWAY18" FIRE PATHWAY18" FIRE PATHWAY18" FIRE PATHWAY18" F IRE PATHWAY18" F IRE PATHWAY 18" FI R E P A T H W A Y 18" FI R E P A T H W A Y 18" FIRE PATHWAY18" FIRE PATHWAY18" FI R E P A T H W A Y 18" FI R E P A T H W A Y REVDATEDESCRIPTIONVERSIONUR09/06/2023INITIAL RELEASESHEET NAMESHEET NUMBERPV-3 PROJECT NAMESHEET SIZEANSI B11" X 17"BOBBY DUNLAP 1723 E LAMBERT LN, PORT ANGELES, WA 98362, USA APN# 0630146500800000 UTILITY: CITY OF PORT ANGELES AHJ: CITY OF PORT ANGELES PROJECT NUMBER: P-0086434ATTACHMENTDETAIL ATTACHMENT DETAILSCALE: NTS1ATTACHMENT DETAIL (ENLARGED VIEW)SCALE: NTS2NOTE: ACTUAL ROOF CONDITIONS AND TRUSSES (OR SEAM)LOCATIONS MAY VARY. INSTALL PER MANUFACTURER(S)INSTALLATION GUIDELINES AND ENGINEERED SPANS FORATTACHMENTS(E) 2"X4" TRUSSES @ 24" O .CENLARGE VIEW(N) PV MODULES(E) ASPHALT SHINGLES ROOF(N) NXT UMOUNT COMBO CLAMP(N) PV MODULES(N) NXT UMOUNT RAIL(N) NXT UMOUNT RAIL CLAMP ASSY(E) ROOF / DECK MEMBRANE(E) ASPHALT SHINGLES ROOF5/16"-18 x 2"SERRATED FLANGE HEX SCREW~4"~4"1-3/4" MIN.EMBEDMENT1.26"1.26"(N) DTD BUTYL ATT ASSY (1/8" BUTYL)2X12-14 SCREW, HWH, SS, SELF-DRW/ #12 EPDM WASHER(N) STRONGHOLD BUTYL ATTACHMENTS, DRK REVDATEDESCRIPTIONVERSIONUR09/06/2023INITIAL RELEASESHEET NAMESHEET NUMBERPV-4 PROJECT NAMESHEET SIZEANSI B11" X 17"BOBBY DUNLAP 1723 E LAMBERT LN, PORT ANGELES, WA 98362, USA APN# 0630146500800000 UTILITY: CITY OF PORT ANGELES AHJ: CITY OF PORT ANGELES PROJECT NUMBER: P-0086434ELECTRICAL LINEDIAGRAM &CALCULATIONELECTRICAL LINE DIAGRAM WITH CALCULATIONSCALE: NTS1L200AEXISTINGGROUNDINGSYSTEM(E) MAIN BREAKER200A/2P, 240V40A/2P(N) 40A/2P PVBREAKER(E) MAINSERVICE PANEL,200A RATED,120/240VBI-DIRECTIONALUTILITY METER1-PHASE, 3-W,120V/240V, 60HzG(N) 60A NON-FUSED,ACDISCONNECT, 240 VACNNL2L1L2L1AC DISCONNECT SHALL BE LOCATEDWITHIN 10' OF UTILITY METERINTERCONNECTION120% RULE - NEC 705.12(B)(3)(2)UTILITY FEED + SOLAR BACKFEED200A + 40A = 240ABUSS RATING x 120%200A x 120% = 240ACNOTE: THE AC DISCONNECT IS LOCATEDWITHIN 10FT OF UTILITY METER·GAS METER LOCATED IN PROXIMITY OF THE PV INSTALLATION, LOAD CENTER, AND/ORDISCONNECTS. DISCONNECTS SHALL BE LOCATED IN COMPLIANCE WITH UTILITY AND THE AHJ(AUTHORITY HAVING JURISDICTION). PV INSTALLATION SHALL COMPLY WITH ALL APPLICABLECODES.·WIRE RATED AND AMPACITY CALCULATED @ 90°C FOR ROOFTOP INSTALLATION AND ATTIC RUNTO INVERTER.·PER NEC REQUIRMENTS GROUNDING CONDUCTORS SMALLER THAN 6AWG SHALL BEPROTECTED IN A CONDUIT, RACEWAY, OR ARMORED PROTECTIVE SHEATHING (NEC 250.64).·THE WORKING CLEARANCES AROUND THE EXISTING ELECTRICAL EQUIPMENT AS WELL AS THENEW ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN ACCORDANCE WITH NEC 110.26.·ANY CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT. (NEC300.6 C1, 310.8 D).·ROOM FOR EQUIPMENT WITHIN 5 FEET FROM MSP.·ALL CONDUIT SHALL BE EMT 3/4" IN DIAMETER UNLESS OTHERWISE STATED.UTILITY PROVIDER:MAIN SERVICE VOLTAGE:MAIN PANEL BRAND:MAIN SERVICE PANEL:MAIN CIRCUIT BREAKER RATING:MAIN SERVICE LOCATION:SERVICE FEED SOURCE:CITY OF PORT ANGELES240VCUTLER-HAMMER(E) 200A(E) 200ANORTH-WESTSERVICE INFO.UNDERGROUNDNOTE:3/4" OR GREATER EMT CONDUITRUN (7/8" ABOVE ROOF SURFACE)SYSTEM SIZE:- 22 x 400W = 8.800 kWDC 22 x 290VA = 6.380 kWACINVERTER SPECIFICATIONSMANUFACTURER / MODEL #QUANTITYNOMINAL OUTPUTVOLTAGENOMINAL OUTPUTCURRENTENPHASE ENERGYIQ8PLUS-72-2-US22240 VAC1.21A(22) ENPHASE ENERGY IQ8PLUS-72-2-USMICRO-INVERTERS (240V)(LOCATED UNDER EACH PANEL)(N) JUNCTION BOX11 MICRO-INVERTERS IN BRANCH #2GL1L1L2L2N20AGBRANCH TERMINATOR Q-TERMFOR IQ SERIES (TYP.)10A/15A20A11 MICRO-INVERTERS IN BRANCH #1L1L1L2L2AB(N) ENPHASE IQCOMBINER BOX 4X2-IQ-AM1-240-4(IEEE1547:2018) [240V]M*IQ-GATEWAYAMBIENT TEMPERATURE SPECIFICATIONSRECORDLOW TEMPAMBIENT TEMP(HIGH TEMP 2%)CONDUCTORTEMPERATURERATE-6°25°90°NOTE-EQUIPMENT RATED AT 75 DEGREESSOLAR MODULE SPECIFICATIONSMANUFACTURER / MODEL #VMPIMPVOCISCTEMPERATURECOEFFICIENTOF Voc# OFMODULESHANWHA Q CELLS Q.PEAK DUOBLK ML-G10+ / t (400W)38.0910.5045.5511.07-0.27%K22MODULE DIMENSION74.0" L x 41.1" W x 1.26" DWire TagConduitWire QtyWireGaugeWire TypeTemp.RatingWireAmpacity (A)Temp.DerateConduitFill DerateDeratedAmpacity (A)InverterQtyNOC (A)NECCorrectionDesignCurrent (A)GroundSizeGround WireTypeAOPEN AIR212 AWGQ Cable90°C301.04N/A31.20111.211.2516.6406 AWGBARE CUB3/4" EMT412 AWGTHWN-290°C301.040.8024.96111.211.2516.6406 AWGTHWN-2C3/4" EMT36 AWGTHWN-290°C751.041.078.00221.211.2533.2806 AWGTHWN-2UTILITY METER NO: E52519 REVDATEDESCRIPTIONVERSIONUR09/06/2023INITIAL RELEASESHEET NAMESHEET NUMBERPV-5 PROJECT NAMESHEET SIZEANSI B11" X 17"BOBBY DUNLAP 1723 E LAMBERT LN, PORT ANGELES, WA 98362, USA APN# 0630146500800000 UTILITY: CITY OF PORT ANGELES AHJ: CITY OF PORT ANGELES PROJECT NUMBER: P-0086434WARNING LABELS &PLACARDPOWER TO THIS BUILDING IS ALSO SUPPLIED FROM THEFOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN1723 E LAMBERT LN(E) 200A MAIN SERVICE PANELWITH (E) 200A MAIN BREAKER(E) UTILITY METER(N) 60A NON-FUSED AC DISCONNECT(N) ENPHASE IQ COMBINER BOX 4(N) PV MODULESCAUTION !MULTIPLE SOURCES OF POWER WARNING DUAL POWER SOURCESECOND SOURCE IS PHOTOVOLTAIC SYSTEMLABEL LOCATION:EMT/CONDUIT RACEWAYS(PER CODE: NEC690.31(D)(2)PHOTOVOLTAIC POWER SOURCELABEL LOCATION:POINT OF INTERCONNECTIONPRODUCTION METERNEC 705.12(D)(3) & NEC 690.59)NOTES AND SPECIFICATIONS:·SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE2020 ARTICLE 110.21(B), UNLESS SPECIFIC INSTRUCTIONSARE REQUIRED BY SECTION 690, OR IF REQUESTED BY THELOCAL AHJ.·SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDSUSING EFFECTIVE WORDS, COLORS AND SYMBOLS.·LABELS SHALL BE PERMANENTLY AFFIXED TO THEEQUIPMENT OR WIRING METHOD AND SHALL NOT BE HANDWRITTEN.·LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTANDTHE ENVIRONMENT INVOLVED.·SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011,PRODUCT SAFETY SIGNS AND LABELS, UNLESS OTHERWISESPECIFIED.·DO NOT COVER EXISTING MANUFACTURER LABELS.ELECTRICAL SHOCK HAZARDWARNINGTERMINALS ON LINE AND LOADSIDES MAY BE ENERGIZED INTHE OPEN POSITIONLABEL LOCATION:INVERTER(S), AC DISCONNECT(S), ACCOMBINER PANEL (IF APPLICABLE).PER CODE(S): NEC 2020: NEC 690.13(B)& NEC 690.15(C)MAXIMUM AC OPERATING CURRENT:NOMINAL OPERATING AC VOLTAGE: 26.62 AMPS 240 VACLABEL LOCATION:AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OFINTERCONNECTION.PER CODE(S): NEC 2020: 690.54SOLAR PV SYSTEM EQUIPPEDWITH RAPID SHUTDOWNSOLAR ELECTRICPV PANELSTURN RAPID SHUTDOWNSWITCH TO THE "OFF"POSITION TO SHUT DOWNPV SYSTEM AND REDUCESHOCK HAZARD IN THEARRAY.LABEL LOCATION:MAIN SERVICE PANELPER CODE(S): NEC 2020: IFC 605.11.3.1(1) & 690.56(C)!3"3"PHOTOVOLTAIC SYSTEM AC DISCONNECTMAIN PHOTOVOLTAICSYSTEM DISCONNECTLABEL LOCATION:MAIN SERVICE DISCONNECT / UTILITY METER(PER CODE: NEC 690.13(B))LABEL LOCATION:UTILITY SERVICE ENTRANCE/METER (WITHIN 3'), INVERTER/DCDISCONNECT IF REQUIRED BY LOCAL AHJ, OR OTHERLOCATIONS AS REQUIRED BY LOCAL AHJ.PER CODE(S): NEC 2020: 690.56(C)(2)RAPID SHUTDOWN SWITCHFOR SOLAR PV SYSTEM!WARNINGTHE DISCONNECTION OF THEGROUNDED CONDUCTOR(S)MAY RESULT IN OVERVOLTAGEON THE EQUIPMENT!LABEL LOCATION:COMBINER BOXPER CODE: NEC 690.31(E)THIS EQUIPMENT FED BYMULTIPLE SOURCES:TOTAL RATING OF ALL OVERCURRENTDEVICES EXCLUDING MAIN POWERSUPPLY SHALL NOT EXCEEDAMPACITY OF BUSBARWARNINGLABEL LOCATION: POINTS OF CONNECTION/BREAKERCODE: NEC 705.12(B)(3)(3)WARNINGPOWER SOURCE OUTPUTCONNECTIONDO NOT RELOCATE THISOVERCURRENT DEVICE!LABEL LOCATION:SERVICE PANEL IF SUM OF BREAKERS EXCEEDSPANEL RATINGNEC 705.12 (B)(3)(2)!LABEL LOCATION:MSP (PER CODE: NEC 705.12(D)(2) &NEC 690.59CAUTIONPHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFED!PHOTOVOLTAICAC DISCONNECTLABEL LOCATION:AC DISCONNECTNEC 690.13(B)S CURRIER CT REVDATEDESCRIPTIONVERSIONUR09/06/2023INITIAL RELEASESHEET NAMESHEET NUMBERPV-6 PROJECT NAMESHEET SIZEANSI B11" X 17"BOBBY DUNLAP 1723 E LAMBERT LN, PORT ANGELES, WA 98362, USA APN# 0630146500800000 UTILITY: CITY OF PORT ANGELES AHJ: CITY OF PORT ANGELES PROJECT NUMBER: P-0086434SAFETY PLANSYSTEM SIZE:- 22 x 400W = 8.800 kWDC 22 x 290VA = 6.380 kWACSAFETY PLANSCALE: NTS1INSPECT ENTIRE JOB SITE FOR HAZARDSSAFETY PLAN CHECKLISTABBR.INDICATE PARKING LOCATION FOR COMPANY VEHICLESSDCVINDICATE LOCATION OF SAFETY DOCUMENTSFIRE EXTINGUISHER LOCATIONFEHFIRST AID KIT LOCATIONFAEYE WASH LOCATIONEWDRINKING WATER LOCATIONDWIDENTIFY HARD HAT ZONEHHZDRAW FALL PROTECTION ANCHOR LOCATIONXDRAW LADDER & ROOF ACCESS LOCATIONLDRAW LADDER ANCHOR LOCATIONLAIDENTIFY ELECTRICAL HAZARD AREASEHINDICATE OTHER HAZARD LOCATION AND SPECIFY(E.G. WATER,TRIPPING,ANIMALS,INSECTS,ETC.)WEATHER FORECASTHOURLYHEAT INDEXHIPP MEASURES7 AM8 AM9 AM10 AM11 AM12 AM1 AM2 AM3 AM4 AM5 AMOTHER WEATHER RELATED HAZARDS & MEASURESWET OR ICY SURFACESHIGH WINDSTHUNDER STOMSWILDFIRE SMOKEOTHERADDRESS & PHONE NUMBER OF CLOSEST URGENT CARE FACILTYCREW LEAD SIGNATURE & DATE(S)CREW LEAD SIGNATURE & DATE(S)NOTE: CREW LEAD MUST CONDUCT A DAILY MEETING TO REVIEW ALL SAFTEY ITEMS.12345NOTE: FOR MULTIPLE DAY JOBS,SAFETY MEETINGS MUST BE CONDUCTED EACH DAY.INDICATE BY INITIALING NEXT TO YOUR SIGNATURE FOR EACH ADDITIONAL DAY.E LAMBERT LNS CUR R I E R C T REVDATEDESCRIPTIONVERSIONUR09/06/2023INITIAL RELEASESHEET NAMESHEET NUMBERPV-7 PROJECT NAMESHEET SIZEANSI B11" X 17"BOBBY DUNLAP 1723 E LAMBERT LN, PORT ANGELES, WA 98362, USA APN# 0630146500800000 UTILITY: CITY OF PORT ANGELES AHJ: CITY OF PORT ANGELES PROJECT NUMBER: P-0086434SPEC SHEETS REVDATEDESCRIPTIONVERSIONUR09/06/2023INITIAL RELEASESHEET NAMESHEET NUMBERPV-8 PROJECT NAMESHEET SIZEANSI B11" X 17"BOBBY DUNLAP 1723 E LAMBERT LN, PORT ANGELES, WA 98362, USA APN# 0630146500800000 UTILITY: CITY OF PORT ANGELES AHJ: CITY OF PORT ANGELES PROJECT NUMBER: P-0086434SPEC SHEETS REVDATEDESCRIPTIONVERSIONUR09/06/2023INITIAL RELEASESHEET NAMESHEET NUMBERPV-9 PROJECT NAMESHEET SIZEANSI B11" X 17"BOBBY DUNLAP 1723 E LAMBERT LN, PORT ANGELES, WA 98362, USA APN# 0630146500800000 UTILITY: CITY OF PORT ANGELES AHJ: CITY OF PORT ANGELES PROJECT NUMBER: P-0086434SPEC SHEETS REVDATEDESCRIPTIONVERSIONUR09/06/2023INITIAL RELEASESHEET NAMESHEET NUMBERPV-10 PROJECT NAMESHEET SIZEANSI B11" X 17"BOBBY DUNLAP 1723 E LAMBERT LN, PORT ANGELES, WA 98362, USA APN# 0630146500800000 UTILITY: CITY OF PORT ANGELES AHJ: CITY OF PORT ANGELES PROJECT NUMBER: P-0086434SPEC SHEETS REVDATEDESCRIPTIONVERSIONUR09/06/2023INITIAL RELEASESHEET NAMESHEET NUMBERPV-11 PROJECT NAMESHEET SIZEANSI B11" X 17"BOBBY DUNLAP 1723 E LAMBERT LN, PORT ANGELES, WA 98362, USA APN# 0630146500800000 UTILITY: CITY OF PORT ANGELES AHJ: CITY OF PORT ANGELES PROJECT NUMBER: P-0086434SPEC SHEETS REVDATEDESCRIPTIONVERSIONUR09/06/2023INITIAL RELEASESHEET NAMESHEET NUMBERPV-12 PROJECT NAMESHEET SIZEANSI B11" X 17"BOBBY DUNLAP 1723 E LAMBERT LN, PORT ANGELES, WA 98362, USA APN# 0630146500800000 UTILITY: CITY OF PORT ANGELES AHJ: CITY OF PORT ANGELES PROJECT NUMBER: P-0086434SPEC SHEETS REVDATEDESCRIPTIONVERSIONUR09/06/2023INITIAL RELEASESHEET NAMESHEET NUMBERPV-13 PROJECT NAMESHEET SIZEANSI B11" X 17"BOBBY DUNLAP 1723 E LAMBERT LN, PORT ANGELES, WA 98362, USA APN# 0630146500800000 UTILITY: CITY OF PORT ANGELES AHJ: CITY OF PORT ANGELES PROJECT NUMBER: P-0086434SPEC SHEETS REVDATEDESCRIPTIONVERSIONUR09/06/2023INITIAL RELEASESHEET NAMESHEET NUMBERPV-14 PROJECT NAMESHEET SIZEANSI B11" X 17"BOBBY DUNLAP 1723 E LAMBERT LN, PORT ANGELES, WA 98362, USA APN# 0630146500800000 UTILITY: CITY OF PORT ANGELES AHJ: CITY OF PORT ANGELES PROJECT NUMBER: P-0086434SPEC SHEETS REVDATEDESCRIPTIONVERSIONUR09/06/2023INITIAL RELEASESHEET NAMESHEET NUMBERPV-15 PROJECT NAMESHEET SIZEANSI B11" X 17"BOBBY DUNLAP 1723 E LAMBERT LN, PORT ANGELES, WA 98362, USA APN# 0630146500800000 UTILITY: CITY OF PORT ANGELES AHJ: CITY OF PORT ANGELES PROJECT NUMBER: P-0086434SPEC SHEETS REVDATEDESCRIPTIONVERSIONUR09/06/2023INITIAL RELEASESHEET NAMESHEET NUMBERPV-16 PROJECT NAMESHEET SIZEANSI B11" X 17"BOBBY DUNLAP 1723 E LAMBERT LN, PORT ANGELES, WA 98362, USA APN# 0630146500800000 UTILITY: CITY OF PORT ANGELES AHJ: CITY OF PORT ANGELES PROJECT NUMBER: P-0086434SPEC SHEETS REVDATEDESCRIPTIONVERSIONUR09/06/2023INITIAL RELEASESHEET NAMESHEET NUMBERPV-17 PROJECT NAMESHEET SIZEANSI B11" X 17"BOBBY DUNLAP 1723 E LAMBERT LN, PORT ANGELES, WA 98362, USA APN# 0630146500800000 UTILITY: CITY OF PORT ANGELES AHJ: CITY OF PORT ANGELES PROJECT NUMBER: P-0086434SPEC SHEETS ELECTRICAL INSPECTION WIRING REPORT APPROVED NOT APPROVED DITCH ROUGH IN/COVER SERVICE FINAL COMMENTS 1. Disconnect door clasp / lock required. NEC 110.3 2. Breaker blank required for opening. NEC 110.12 NOTIFY INSPECTOR at (360) 808-2613 WHEN CORRECTIONS ARE COMPLETED WITHIN 15 DAYS DATE PERMIT # INSPECTOR 11/1/2023 23-1082 TAP OWNER CONTRACTOR Lumio PROJECT ADDRESS 1723 Lambert Ave ELECTRICAL INSPECTION WIRING REPORT APPROVED NOT APPROVED DITCH ROUGH IN/COVER SERVICE FINAL COMMENTS NOTIFY INSPECTOR at (360) 808-2613 WHEN CORRECTIONS ARE COMPLETED WITHIN 15 DAYS DATE PERMIT # INSPECTOR 11/27/2023 23-1082 TAP OWNER CONTRACTOR Lumio PROJECT ADDRESS 1723 E Lambert Ln