Loading...
HomeMy WebLinkAbout1312 Campbell Ave Technical - Building 1- -- -- - -- -- - TECHNICAL r----- ... Apartment Complex Structural Design for Gary Caswell Campbell Avenue Port Angeles, WA v ~- 4 SEASONS ENGINEERING, INC. 619 SOUTH CHASE STREET PORT ANGELES, WA 98362 r / \L\ \ ~D~ ~ \\ ~I . ~ , "' February 14, 2005 City of Port Angeles Building Department 321 E. 5th Street Port Angeles, WA 98362 Subject: Scope of Engineering for: Structural Design Gary Caswell Campbell Avenue Port Angeles, WA ." Enclosed is the structural design of the Apartment Complex for Gary Caswell. At this time, portions of this structure that have been reviewed by the enQineer include: .~ 1. Lateral Forces 2. Beams and Headers 3. Foundation * -., Please give me a call if you need any additional information. .- ,. Sincerely S)~9~9[- Donna J. Petersen P .E. , ~ T. Structural Design Gary Caswell Campbell Avenue Port Angeles, WA DESIGN CRITERIA DESIGN STRESSES ELEVATION LESS THAN 625 FT . DOUGLAS FIR/LARCH #2- 2 & 4 X Fb = 900 PSI Fv= 95 PSI E= 1.6 (10)6 PSI SNOW LOAD GROUND= 25 PSF LIVE LOAD = 40 PSF (FLOOR) DEAD LOAD = 10 PSF (FLOOR) DEAD LOAD = 10 PSF (ROOF) DEAD LOAD = 7 PSF (CEILING) DOUGLAS FIR/LARCH #1- 2 & 4 X Fb= 1200 PSI Fv= 95 PSI E= 1.8 (10)6 PSI EXPOSURE C HEM FIR #2- 2 & 4 X Fb = 850 PSI Fv= 75 PSI E= 1.3 (10)6 PSI GLU-LAM BEAMS 24F-V4 Fb= 2400 PSI (T) BOTTOM Fb= 1850 PSI (T) TOP Fv= 165 PSI E= 1.8 (10)6 PSI WIND SPEED, V FM = 80 MPH 3 SEC GUST, V3S = 100 MPH SEISMIC ZONE O2 SOIL BEARING = 1500 PSF REFERENCES (1) INTERNATIONAL BUILDING CODE 2003 (2) INTERNATIONAL RESIDENTIAL CODE 2003 (3) TIMBER CONSTRUCTION MANUAL 3RD ED by AITC (4) CONNECTORS FOR WOOD CONSTRUCTION by SIMPSON STRONG-TIE (5) WESTERN WOODS USE BOOK by WESTERN WOOD PRODUCTS ASSOCIATION MAY 1996 (6) NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION 1997 (7) ROSBORO-APA WOODCAD, VERSION 1.1 by ROSBORO GLULAM RESOURCES 2000 (8) RISA-2D RAPID INTERACTIVE STRUCTURAL ANALYSIS - 2-DIMENSIONAL VERSION 5.5 2001 ~ "" General Notes 1. Ground snow load = 25 PSF 2. Maximum soil bearing capacity = 1500 PSF 3. Seismic Zone 02 4. Wind, VFM = 80 MPH, 3 second gust, V3S = 100 MPH, Exposure "C". 5. Notations on drawing relating to framing clips, joist hangers and other connecting devices refer to catalog numbers of connectors manufactured by the Simpson Strong-Tie Company, San Leandro, CA. Equivalent devices by other manufacturers may be substituted, provided they have ICBO approval for equal load capacities. 6. Roof Trusses: Trusses shall be designed by the manufacturer and design calculations shall be submitted for approval prior to fabrication. Each wood truss shall carry a grading stamp. Top chord members shall be sized to accommodate 25 psf snow load and appropriate snow drifts as noted in the UBC. No field modification of trusses will be allowed without the engineer's approval. Live load truss deflection shall be limited to U360. Total load deflection will be limited to U240. 7. Girder trusses shall be attached to wall framing with Simpson LGT2, minimum 2000 pounds uplift, or equal. 8. Contractor shall provide temporary bracing and shoring for the structure and structural components until all final connections have been completed In accordance with the plans. 9. Contractor shall be responsible for all the required safety precautions and methods, techniques, sequences or procedures required to perform his work. 10. Contractor initiated Changes shall be submitted in writing to the structural engineer for approval prior to fabrication or construction. 11. Drawings indicate general and typical details of construction, where conditions are not specifically indicated but are of similar character to details shown, similar details of construction shall be used. General Concrete Notes (The Following apply unless shown on the plans) 1. All materials and workmanship shall conform to the requirements of the drawings, specifications, and the 2003 International Building Code. 2. Concrete shall attain a 28 day strength of F'c= 2500 psi, 5 1/2 sacks of cement per cubic yard of concrete. 3. Reinforcing steel shall conform to ASTM A615-76A, Grade 40, fy= 40,000 psi. 4. Reinforcing steel shall be detailed (Including hooks and bends) in accordance with 30 bar diameters or 2'.0" minimum. Provide corner bars In all wall Intersections. Lap corner bars 30 bar diameters or 2'.0" minimum. 5. Lap adjacent mats of welded wire mesh one full mesh at sides and ends. 6. No bars partially embedded in hardened concrete shall be field bent unless specifically so detailed or approved by the structural engineer. 7. Concrete protection (cover) for reinforcing steel shall be as follows: Footings and other unformed surfaces: earth face 3" Formed surfaces exposed to earth, walls below ground, or weather: #6 bars or larger 2" #5 bars or smaller 1-1/2" Walls Interior face 3/4" 8. Footings shall bear on solid unyielding natural earth free of organic material 4- Single story structures Two story structures Three story structures 12" below original grade 1S" below original grade 24" below original grade 9. Slabs shall be placed upon compacted granular fill, 2" minimum thickness. Wood Framing Notes (The Following apply unless shown on the plans) 1. All wood framing details not shown otherwise shall be constructed equal to or better than the minimum standards of the 2003 I.B.C. 2. Minimum nailing requirements: Unless otherwise noted, minimum nailing shall be In accordance with Table R602.3(1) of the 2003 I.B.C. 3. All structural framing lumber such as 2x_ joists, and rafters to be Douglas Fir No.2, Spruce/Pine/Fir No.2, or Hem/Fir No.2 kiln dried. 4. All 2x_ studs and blocking to be Douglas Fir construction, Spruce/Pine/Fir construction; or Hem/Fir construction grade. 5. All structural posts to be Douglas Fir No.2. 6. All structural headers to be 4x_ Douglas Fir No.2. 7. All Glu-Iam beams to consist of Douglas Fir kiln dried 24F-V4 standard grade unless noted otherwise on plans. S. All 2x framing lumber exposed to weather, and/or moisture shall be Hem-Fir No.2, pressure treated In accordance with the American Wood Preservers Association standard for above ground use. 9. All 4x and 6x structural lumber exposed to weather, and/or in ground contact shall be Hem-Fir No.2, pressure treated In accordance with the American Wood Preservers Association standard for ground contact use. 10. Framing connectors, nalls, bolts, and other fasteners In contact with pressure treated wood shall have the follOWing finishes: Wood Treatment Finish CCA-C and DOT Sodium Borate (SBX) Galvanized, 0.60 ozlff' ACQ-C, ACQ-D, CBA-A, CA-B, Other Borate Post Hot-Dip Galvanized, ZMAX galvanized, (Non-DOT) 1.S5 ozltr. , or SST300-Stalnless Steel Steel Ammoniacal Copper Zinc Arsenate (ACZE) SST300-Stalnless Steel and other pressure treated woods. 11. When using Stainless Steel or hot-dlp galvanized connectors, the connectors and fasteners should be made of the same material. Stainless Steel fasteners shall not be use In applications where contact with Galvanized and Post Hot-Dip Galvanized metals will occur. 12. Individual members of built-up posts and beams shall each be attached with 16d spikes at 12" o.c. staggered. 13. All columns In framed walls to be well nailed into adjacent framing in order to resist lateral movement. 14. Provide solid blocking for wood columns and multiple studs through floors to supports below. 15. Provide 4x10 headers, or double 2x10 headers over and double studs each side of all openings In stud bearing walls not detailed otherwise. 16. Provide 4xS headers, or double 2xS headers over and double studs each side of all openings In non-structural stud walls not detailed otherwise. 17. At joist areas: Provide solid blocking at bearing points. Provide double joists under all load bearing partitions. Provide double joists each side of openings unless detailed otherwise. 1S. Provide double joist headers and double joists each side of all openings In floors and roofs unless detailed ,5' otherwise 19. Toenail Joists to supports with 2-16d nalls, 2-10d box nails for T JI Joists. Attach all beams at the roof exceeding S'O" in length with Simpson ST 292 strap each end. 20. Attach joists to flush headers and beams with Simpson "U" series metal joist hangers to suit the joist size. 21. All wood stud walls shall have lower wood plate attached to wood framing below with 16d nails at 12" o.c. staggered, unless otherwise noted In the shearwall schedule. 22. Plywood roof and floor sheathing unless otherwise noted on plan shall be laid up with face grain perpendicular to supports and nailed with Sd nails @ 6" o.c. to framed panel edges and over stud walls shown on the plans @ 12" o.C. to intermediate supports. Provide approved plywood clips @ 16" o.c. at unblocked roof sheathing edges. Provide solid blocking at lines of support at floors. Toenail blocking to supports with 16d @ 12" o.c., unless otherwise noted in the shearwall schedule. 23. Provide continuous solid blocking at mid-height of all stud walls over 10' in height unless wallis blocked per shear wall note. 24. Plywood wall sheathing for noted shear walls shall have solid blocking at all sheathing panel edges. See shear wall schedule for further notes. o I - I &-- -.._...~-----~ U) ~ l l --L \S H-E-A.e-- \AI h'L.L- /,-A.. your L-A-s w E L..--L A-:p I(~ 4SEASONS ENGINEERING, INC (360) 452-3023 619 S. Chase St., Port Angeles, WA 98362 DATE: 2-- SCALE: DRAWN BY: CHECKED: SHUT 7::f- 1 Of . 2003 IBC WIND ANALYSIS WIDTH LENGTH LEAST DIM 2003 IBC SEISMIC ANALYSIS - SIMPLIFIED BASE SHEAR BUILDING DESCRIPTION ,;, 46 '100 46 S1 0.50 FIRST FLOOR = 9 Ss 1.25 SECOND FLOOR = ({r'.' . 9... SITE CLASS 0 w % ROOF HEIGHT = 4.6 Fv 1.50 AVERAGE HEIGHT OF BUILDING 22.6 Fa 1.00 2A= 9.2 Sm1 0.75 WIND EXPOSURE C Sms 1.25 WIND SPEED 80MPH Sd1 0.50 ROOF PITCH 5 12 22.62 Sds 0.83 p. = AlwPs30 SEISMIC USE GROUP 1 SEISMIC DESIGN CATEGORY 0 p. = AlwP.30 A= I = LC1, Ps30 = LC1,P. = LC2,p.30 = LC2,P. = RESPONSE MODIFICATION FACTOR 61/2 w AREA A, Ps30 = 1.32 1 19.9 26.29 19.9 26.29 SEISMIC BASE SHEAR COEFFICIENT= 0.154 AREA B, ps30 = 1.32 1 3.2 4.23 3.2 4.23 CONNECTION OF SMALL ELEMENTS AREA C, ps30 = 1.32 1 14.4 19.03 14.4 19.03 SHEAR COEFFICIENT= 0.111 AREA 0, ps30 = 1.32 1 3.3 4.36 3.3 4.36 HORIZONTAL DIAPHRAGMS AREA E, ps30 = 1.32 1 -8.8 -11.63 -3.4 -4.49 SHEAR COEFFICIENT= 0.1667 AREA F, ps30 = 1.32 1 -12 -15.85 -6.6 -8.72 BEARING AND SHEAR WALL AREA G, ps30 = 1.32 1 -6.4 -8.46 -0.9 -1.19 OUT OF PLANE WALL FORCES AREA H, ps30 = 1.32 1 -9.7 -12.82 -4.2 -5.55 SHEAR COEFFICIENT= 0.3333 E oh 1.32 1 -16.5 -21.80 -16.5 -21.80 MASONRY AND CONCRETE OUT OF PLANE Goh 1.32 1 -14 -18.50 -14 -18.50 SHEAR COEFFICIENT= 0.6667 Caswell. LA TERAL.IBC2003.xls 8 MAIN LATERAL FORCE RESISTING SYSTEM - WIND LOADS SEISMIC LOADS (AREA PRESSUREl/LENGTH . SHEAR UPPER TRIB WIDTH HEIGHT PS FORCE LENGTH SHEAR TRIB WIDTH DL SHEAR SHEAR SHEAR LEVEL AREA FT. FT. PSF LBS FT PLF AREA FT. PSF COEFF. LBS PLF 1 A 9.2. 9.0 26.29 ROOF 27.0..... 17\;l B 4.23 FLOOR ,. 0.0 10 C 15.8 9.0 19.03 WALL .8.0 5 X. 0 4.36 4882.5 . 100 48.8 ETC. i.O.O o ',' 0.154 7676.9 76.8 2 A 9.2 . 9.0 26.29 ROOF 23.0 17 B 4.23 FLOOR 0.0 10 .. C 11.8 9.0 19.03 WALL 8.0 5 0 4.36 4197.6 100 42.0 ETC. O.OJ '.. ,. oy 0.154 6630.8 66.3 3 A 9.2 4.0 26.29 ROOF '52.0; 17 B 9.2 9.0 4.23 FLOOR 0.0 10 C 3.3 4.0 19.03 WALL ".38.0 '5 0 3.3 9.0 4.36 1698.3 42 40.4 ETC. 0.0' 0 0.154 6875.1 163.7 4 A 26.29 ROOF 0.0 ,. 17 B 4.23 FLOOR 0.0: ,10 C 25.0 4.0 19.03 WALL 0.0' 5 " 0 I' 25.0 9.0 4.36 3250.0 38, 85.5 ETC. >:....0.0,> oW; 0.154 0.0 0.0 5 A 26.29 ROOF 0.0 17f B 4.23 FLOOR 0.0" .10 . C 25.0 4.0 19.03 WALL 0.0 5;! 0 25.0. 9.0 4.36 3250.0 42 77.4 ETC. '0.0 0 0.154 0.0 0.0 6 A 26.29 ROOF '1,'0.0'\' 17'; B 4.23 FLOOR 0.0, 10';; C 25.0 4.0 19.03 WALL 0.0 5 0 25.0. ; 9.0 4.36 3250.0 38 85.5 ETC. ",0.0'.. "; >01;' 0.154 0.0 0.0 7 A 9.2 4.0 26.29 ROOF . 52.0 17 " B 9.2 9.0 4.23 FLOOR '0.0, 10 ,f. C 3.3 4.0 19.03 WALL 36.0' 5 '" 0 3.3 9.0 4.36 1698.3 42 40.4 ETC. 0.0 o ! 0.154 6875.1 163.7 LOWER TRIB WIDTH HEIGHT PS FORCE LENGTH SHEAR TRIB WIDTH DL SHEAR SHEAR SHEAR LEVEL AREA FT. FT. PSF LBS FT PLF AREA FT. PSF COEFF. LBS PLF 1 A 9.2 18.0 26.29 ROOF '''27.0 17" B 4.23 FLOOR '0 25.0 " .10" C 15.8' 18.0 19.03 WALL 16.0 5 0 .,. 4.36 9765.0 100 97.7 ETC. 0.0 oW 0.154 12138.5 121.4 2 A 9.2 . 18.0 26.29 ROOF 23.0] 17" B 4.23 FLOOR 21.0 10;- C 11.8 18.0 19.03 WALL 16.0 [ 51: 0 4.36 8395.2 100 84.0 ETC. 0.0 0:' 0.154 10476.9 104.8 3 A 9.2'! 13.0 26.29 ROOF 52.0/' 17 B 9.2 9.0 4.23 FLOOR 50.0 10 C 3.3 13.0 19.03 WALL 72.0 5 0 3.3 9.0 4.36 4440.4 42 ., 105.7 ETC. . 0.0 O'iil' 0.154 11268.9 268.3 4 A 26.29 ROOF 0.0 17 B 4.23 FLOOR I> 0.0' 10~ C 25.0 , 13.0 19.03 WALL 0.0 5 0 25.0' 9.0 4.36 7184.4 38 188.5 ETC. .... 0.0 O~ 0.154 0.0 0.0 5 A 26.29 ROOF 0.0 171 B 4.23 FLOOR 0.0 10 C 25.0 13.0 19.03 WALL 0.0' o. 6 0 .25.0' c' ! 9.0 4.36 7164.4 42 170.6 ETC. 0.0 0,:, 0.154 0.0 0.0 6 A 26.29 ROOF 0.0 1H B 4.23 FLOOR 0.0 .10'~ C 25.0 13.0 19.03 WALL 0.0 5 0 25.0 9.0 4.36 7164.4 38 188.5 ETC. 0.0 "oT 0.154 0.0 0.0 7 A 9.2 13.0 26.29 ROOF 52.0 17,. B 9.2 9.0 4.23 FLOOR 50.0 10 C 3.3 13.0 19.03 WALL 72.0. 5,0 0 3.3, 9.0 4.36 4440.4 AD 1 -.; 0" 0.154 11268.9 268.3 Cj SHEAR WALL SCHEDULE " 7 Mark Sheeting Fastener spacing Intermediate Framing Battom plate na",ng 4l Anchor Baits Maxlumum Notes doubled stud snllclna allowb/e o all edges framing nail backing Sheeted Sheeted Sheeted Sheeted shear (Blacked) spacing size one side both sides one side bath sides L ( 7/16- 058 8d 0 6- OC 8d 06- DC 2x 2.w PLF 2,3,6 ( ( 0 OR for stud framing 024- 2-16d 0 2-16d 0 5/S- X1O- 5/S" X10" 480 PLF 8d 0 12" OC L 15 GA 04" OC for stud framln 016" 12"OC S"OC o 48" O.C. 030" O.C. . ) c . 7/16- 058 Bd 04" OC Bd 06" OC 2x 350 PLF 2.3.5,6 f OR for stud framing 024" 2-16d 2-16d 0 5/B" X10" 5/B" X10" 700 PLF (3) 8d 0 12- OC 15 GA 03" OC for stud famlng 016" o 10"OC 5"OC O.w" O.C. 020" O.C. ~ 1/2" COX Bd 0 3- OC Bd 0 6" OC 3x 490 PLF 2,3,4,5,6 . ( (j) plywood OR for stud framing 024- or 2-16d 2-16d 0 5/B- X10" 5/8" X10- 9BO PLF c- Bd 0 12" OC 15 GA 02-1/2" OC for stud framing 016" DBL2x o 7"OC 3-1/2"OC o 2B" O.C. o 14" O.C. 1/2" COX 10d 03" OC 10d 0 6" OC Jx 600 PLF 2, 3, 4, 5, 6 0 plywood for stud framing 024" or 2-16d 2-16d 0 5/B" X10" 5/B" X10" 1200 PLF 10d 0 12" OC for stud framing 0 16" DBL2x o 6"OC J"OC 024- O.C. o 12- O.C. 1/2" CDX 10d 02" OC 10d 06" OC Jx 770 PLF 2, J,5, 6 0 plywood for stud !ramlng 024- or J-16d J-16d 0 5/8" X10" 5/B- X10- 1540 PLF 10d 0 12 OC DBL2x o 6"OC J"OC o 1B- O.C. o 9- O.C. for stud framing 0 16" @ 1/2" G~ 5d COOLER 0 4" OC 5d caaler 0 4" OC 2x 2-16d 0 5/B" X10- JOO PLF J,6 both sides OR OR 5d G~ 0 4 " OC 5d G~ 04" OC 12"OC 048" O.C. 0 ~{.B G~ 6d COOLER 0 4 OC 6d caaler 0 4" OC 2x 2-16d 0 5/B" X10" J75 PLF J,6 both sides OR OR 6d G~ 0 4" OC 6d G~ 04" OC 10"OC OJ6" O.C. Notes: I 1. ALL NAILS SHALL BE GALVANIZED BOX NAILS OR COMMON NAILS, F1fc.TERNERS a~MEE)l TH!hQ;LLOl'rfNG CRITERIA: 8d =01J1-d' X 2 1/2" I d caaler -. dla 1- B min. comman . .:a. -_ m n. 5d G~ -0.OB6"dla X 1-S/B" min. 10d common =.0.148 dla X ~ min. 6d coaler -0.092"dla X 1-7/B" min. i'" 8d box =0.11 J "dla X 2-1/2 min. 6d G~ -0.092" dla X 1-7/B- min. 10 box -0.12S dia X 3"mln. 16d common -0.162"dia X 3-1/2" min. 15 GA. staple -0.072"dia X 1-1/2" min. 2. PROVIDE APA RA TED SHEA THING PLYWOOD OR 058 APA RA TED SIDING 303 OF INNER SEAL OSB RA TED PANEL SIDING ON ALL EXTERIOR WALLS AND NAIL PER NOTE 1. 3. SPECIFIED SHEA THING AND SIDING PANEL EDGES SHALL BE BACKED l'rfTH 2" OR 3" FRAMING (PER THE TABLE) INCLUDING FOUNDA TlON SILL PLATES, VERTICAL FRAMING, AND BLOCKING. PANELS MA Y BE INSTALLED EITHER HORIZON TALL Y OR VERTlCALL Y (SEE NOTE 4 FOR EXCEPTION). NIIILS SHALL BE STAGGERED FOR J" FRAMING. 4. 7/16" 058 MA Y BE SUBSTITUTED FOR 1/2- COX PL YWOOD IF FRAMING IS SPACED AT 16" ON CENTER, OR PANELS ARE APPUED WITH LONG DIMENSION ACROSS STUDS FOR FRAMING SPACED AT 24" (BLOCKED). S. 'M-IERE PANELS ARE APPUED ON BOTH FACES OF II WIILL AND NAIL SPliCING IS LESS THAN 6 INCHES ON CENTER ON EITHER SIDE, PIINEL JOINTS SHALL BE OFFSET TO FALL ON DIFFERENT FRIIMING MEMBERS OR FRAMING SHALL BE J-INCH NOMINAL AND NAILS ON EACH SIDE SHALL BE STAGGERED. 6. NAILS TO BE DRIVEN FLUSH WITH SHEA THING. DO NOT OVER DRIVE NAILS. 7. ALL SHEAR PANELS SHALL BE BLOCKED. /7) I ..., Ol Ul }> }> }> }> .". w I\) ~ ~ }> mOC1lJl}> mOC1lJl}> zF Ill! r- en .". .". .". ~ .". ~ .". .". Ol .". Ol .". Ol .". ~ ~ ~ 00 Ulf:)Ulf:)UlI\) UlCOUlCOUloo r-mZ ~ ~ m m m m mom ~ m ~ m ~ ~ }> c ;u en en ~ ~ m ~ ~; ;Uo """"0000 ...,..., 0000 00 Ul!-" ...,..., UlUl ~~ ~Ul ~~ ~~ (") Q) ~ ~ ~ m ~ r- (XI (") N o o eN X (jj ~ ~ Ol Ol W w :.... :.... 00 .". .". I\) I\) w ~ t o ~ o Co Ul I\) o ..., ;" .". o o o z o z m o 0 o 0 00 1 [ ~.. f'~" ], ~ h.t it f ~ :L ~ ~ 1>. o o ~ ~ J J.' ~: .... J8 ~ o o ~ :.... ~ ~ .". 1 , 10 I, o o z o z m o 0 o 0 00 00 00 o 0 ~ ~ ~ ~ ~ N ~ ~ ~ ~ ~ ~ ~ ~ ~~ I\)~I\)~I\)O) 8""~""80l :.... :.... 0 Co 0 Co 0 ~ :.... ~ _ ~ :.... ~ 00 00 00 00 00 00 +.'" It"" I' ~( ''i(. (. ~ r l w 1 .". .". ~ 00 ' I\) I\) N ..., I, ... ~, "\0.-, nX r., ".P h o l' . ;r,. -.to ;;8' ~.-' " ~ ~ o o Ul Ul ~ ~ (i) I ~. \' J..". o , ,'i:' o o z o z m " ~ .\. ,,; r 1 to ; ',. o ~~,~~ : ...r.; ~;j~i,8 ~' '.. J., ,..", ~ o o ~ :.... ~ (i) ~ lJl i, .". JtA~;f, ~. o .[ .'1 o o z o z m :!: l' 0 ~... -... f\) 0 .... t .I ~ 't"'" ; (,\J. l ,:,; '"" 0 ~ Oi "" ~: "~JI 1:>1' T' !... :" " ,Y'" '!' Ii' t' ~(~ j,I,/;.1 "" I\) ,I' I\) ~ ~ ~ ~ ~ r , j~' I ' ~:l)l~J'~i ~ ~'. '~f" ' F' '1.11: ~" 1 ,. -I ~ .{~<.n 1 ". t Ul Ul Ul Ul Ul 00000 p ~~ ,;~::: 1 :.f J ,i\ ~"''''! ~',k', "',' p;: ,:.t,;:) ". ; \"t. "I( '~K o 0...... 0 ~ ~8~ ~r-:'" ~ '" i. 't':f'" ;-~.,',. o Co Ul o ...... 0 ....a. 0 ~g~8~ I\) o ..., ;" I\) I\) I\) I\) I\) I\) I\) I\) I\) I\) 00 00 00 00 00 00000 .... .... ...... ...... .... f;~ i" ii, 1,,1:'/ ( '~' li~ ci ~" tl ~f!' 1:21 J ,r .; ", '{ .~ ii 'ft -'It It" i'.{'- ',R, ~ o,~.,.... 9,6 , ..,:~ ,)'1':, t.,. ,- "..11',; (:;\, t~ ~ ~, t" 'fl o o ... ... o~o~o 0:'" (:) :.a. &:, z o z m z~z~z O~O~O ZCZCZ m>>m>>m 00 00 00 00 00 -1':' ~:~ 1;<;" N f\) {, ~~~::8 t ':..">' .....' ;" ",,'i Ki. "" Ul'" Ul 'w "1 ~.'" 1$,' i~~~:~ ~t\ \~- w .{;., w "w ;" ;" ;" Ul "" Ul ..". Ul J' ,,jf" I,.;' .,.' ;, I .l, ."" .",,:,"", t. "" ., ,.~w' ':'\~\~ ,~. Ul Ul Ul Ul Ul 00000 "",i., \\ 1- ii. t 1'1:,'., 000 ~iB~: ',,;!'!l :;;j'~ I "'A .".\ ." ) 0 S ~ ~;:: .. 00000 <:~<:~<: ...... ~ ... ... ..... co co co co co Ul Ul Ul Ul Ul ~~~~~ .... .... .... .... .... t ,\'i!: 2::: ~ii ~ '~ ~ ~ ~ \:' ;j" C1I -W~^lUl r ~ i 1:' .!~ I ) ~ i ijj'~, !... o 0 ;' ,i!~ f~ 'f);.; 00000 00000 zzzzz 00000 zzzzz mmmmm ~ m ;!I Q 0 ~ ~-- ~ ~ ~ . :i! ~ m ;!I Q ~ -t ~ ~ . :i! :,l m ~ ~ 0 -t ~ ~~ (i) -j!. ~ 0 m ~ Q c: ~ ~ -t r- r- ~ m Q'f1. ~ 0 -t ~ en ~ ~ c: -t r- ~ r- !i> > ;U ~ 2 rn ~ lj Cii -t oof ~ g ~ Z Z 0 -t m en C ~ ~ rn !;; ~ Q ;U z en ~ ~ ~ ~ r- ~ mr-;u ;!I ~ ~ ~ lJl ~ r- -t ~ 0 ~ . g lJl c: r- ~ me . ~ C ~ 00 ~ r- z C r- c: CD 'tI ~ '2 - ... ~ m ~ i: 0 i ~ ~__iil i: C ~ en - ~ !U ~ ;u ~ r- r- C m en Q z ~ r- .... C .!!!...!:. ;u o o , ~ ~E ~ r- f'" g ;u c= l:! II ~ I I I R5 # I .( Cj 'ea ,( :s ~A-AJ i 5' T'E: IE . :?-, :: ? z-::;.. 0)0) 2>~ C~ OJ'b f 4-'PLO DP#,2... H-f3-A. DE ~- ~'I 1 ~ :S-PA-t\) I ~' If:::- (is . 12.. I == F';L =- .7 59 4-#=. 4'{: 12- D r-:-::#:-z-. t r-'-;L l' rat f ~A-Ds.g-. #2- 1-- I ~-P A- rJ 2~'~IB, 'i21 ::;. ez.::: =3 3 ~ I 41=- ~ 'k 11'1' Cj ,( L1LV..-LAvV\ "2,4. F:' .- VA- H ]:::.A-'D€=.f2-. :t1:. .3 S \ -S:PA-tJ i:"-"'t...~..~ r1-7~' TEl 15 , 1 s' r g.. -=- gz.. = I b'3 2>-t\: __. 4-- Y- 10 DFtF.2-- F~o~ ~ot~TS 14--1h..-1 :s PA-I\J (LLE+?$~A0 '111/b '( nl /2-10 e,,{~ 101C, ~~~ (~e I/r/~'1 :&.I.,5'O~ @.I~'I".(, o\(. ~(2 111--/~ ~l L P:L 2-[) (€{Go, (. 0It... f;l T:'B :tt- ( . f ;z.. I SPA-tJ I I I 6 Ii!- PLcrJ2. nLE . i2- ( ':::... e;t..::. ? '1 1- / {z) - 1~/4- YI'~ 't/b:PSALA~ '=FD.tj:: Z. q '& 1 ~ ?A;-^-J 2- 12-- I f5~LLoA.JY T~ l8 . F I ::. ~ z- ::. 'I & ~ :t:i::. 4'f 10 ])F-;p.z... ..----'-- -BA-u.oJVy J O~ '6 IS 5 ( 6. -:p.4;. to 1- L--~ I Cf) -P'6"F- ?,. ~'1C.z:.-.::c ~ C)o DL-.> J 1-. T.::s-F- 2-:rb DF.tl:z. @_I~IIOtC, c.t\-tJlt L...G lk;--F:'- "FL-OD e. __..\ Cll '"'S'I:S -1- { c.A-Nrf L-.1:::--VE: 12-.. [f3ArUoNV J 10 f If'VTEJ2..0R.-BkC)L SP-+N I ( r/0 f'1?x::..:'[" 6Q) ~...l b ,I 0 1.:::., ..~--._-.. --. l--l--EA-b t.::= ~ -1+. 4- C:, I ~'P~l 1Z1 1 ~L I , -7 \/ ' 1:" ',.-: I k' l.^o/I::;:'" "1 I';). 1-LDOf:- + 2.1').. uALc.oNy P.. '''" ....:-.=2 <:::.>< .A t.t: I - ;-::.-- .~) , -r- 12.\ ~~.. 12].._::: t8{8 t2,Y'>4.~ 42--lz~., 4-'1 (0 DF- ~-z-. DATE, '2 .lln /0 c;;- CA5WS-L-L- ;tV) '~ 4SEASONS ENGINEERING, INC (360) 452-3023 619 S. Chase St., Port Angeles, WA 98362 SCAlf: DRAWN BY, J ~p CHECKED: SHEET /5 0' RB#1-Roof Beam Eagle Point Project: GARY CASWELL Job: CASWELL APARTMENTS Page 1 10:49:3602/14/05 Designed by: Donna J. Petersen P.E. Client: CASWELL APARTMENTS Checked by: Input Data Chackof 4x10 No. 2-DouglaaFI....Larch-Dlman.lonal ~ Left Cantilever: None Main Span: 9'6" Check for repetitive use? No Tributary Width: 5' Dead Load: 17 psf Live Load: 20 psf Allow. LL Deflection: U240 Allow. TL Deflection: U180 Eb: 1600000 psi Fy: 180 psi Right Cantilever: None Slope: 0:12 Snow Load: 25 psf DOL: 1.150 Fb: 900 psi Design Checks Reaction Bending - X Sh..r LL DefI. TL Deft. Ib' .,.1 pili In In Max. Value 997.5 569.584 39.338 -0.062 -0.1042 Allowable 3281.47 1242 207 0.475 0.6333 % of Allow. 30~ 46~ 19 ~ 13 ~ 16 ~ Location 0' 4'9" 8'8-3/4" 4'9" 4'9" Reactions and Bearing Support Location ft Min. Bearing In Reaction Ib 0' 9'6" 1.5 1.5 997.5 997.5 Self-weight of member is not included. Member has an actuaVallowable ratio in span 1 of 46 ~ %. Design is governed by bending fb/Fb. Goveming load combination is Dead+Snow Condition 1 w/Pattern Loads. Maximum hanger forces: 997.5 Ib (Left) and 997.5 Ib (Right). Program Version 8.2 - 912012002 I~ HEADER#1-Roof Beam Eagle Point Project: GARY CASWELL Job: CASWELL APARTMENTS Client: CASWELL APARTMENTS Page 1 10:50:2502/14/05 Designed by: Donna J. Petersen P.E. Checked by: Input Data Check .of 4x12 No.2-Douglas f;lr-Larch-Dlmenslonal rI Left Cantilever: None Main Span: 6' Check for repetitive use? No Tributary Width: 19' Dead Load: 17 psf Live Load: 20 psf Allow. LL Deflection: U240 Allow. TL Deflection: U180 Eb: 1600000 psi Fy: 180 psi Right Cantilever: None Slope: 0:12 Snow Load: 25 psf DOL: 1.150 Fb: 900 psi Design Checks Reaction Ib Bending. X psi 583.68 1138.5 51 rI 3' Shear psi 65.484 207 32 rI 11-114" Max. Value Allowable % of Allow. Location 2394 3281.47 73 rI 0' LL Deft. In -0.0208 0.3 6r1 3' TL Deft. In -0.035 0.4 8r1 3' Reactions and Bearing Support Location ft Min. Bearing In Reaction Ib O' 6' 1.5 1.5 2394 2394 Self-weight of member is not included. Member has an actuaVallowable ratio in span 1 of 51 rI %. Design is governed by bending fblFb. Governing load combination is Dead+Snow Condition 1 w/Pattem Loads. Maximum hanger forces: 2394 Ib (Left) and 2394 Ib (Right). Program Version 8.2 - 912012002 Ib HEADER#2-Roof Beam Eagle Point Project: GARY CASWELL Job: CASWELL APARTMENTS Page 1 10:50:4602/14/05 Designed by: Donna J. Petersen P.E. Client: CASWELL APARTMENTS Checked by: Input Data Check.of 3 118"x9" 24F-V4-Un-Balanced Layup-Glulam - Western tI Left Cantilever: None Main Span: 7' Right Cantilever: None Check for repetitive use? No Tributary Width: 23' Slope: 0:12 Dead Load: 17 psf Live Load: 20 psf Snow Load: 25 psf Allow. LL Deflection: LJ240 Allow. TL Deflection: U180 DOL: 1.150 Eb: 1800000 psi Fy: 240 psi Fb: 2400 psi Design Checks Reaction Bending. X Shear LL Defl. TL Deft. Ib ~I pSI In In Max. Value 3381 1682.99 145.079 -0.0909 -0.1527 Allowable 3415.35 2760 276 0.35 0.4667 % of Allow. 99 tI 61 tI 53 tI 25 tI 32 tI Location 0' 3'6" 9" 3'6" 3'6" Reactions and Bearing Support Location It Min. Bearing In Reaction Ib 0' 7' 1.681 1.681 3381 3381 Self-weight of member is not included. Member has an actuaVallowable ratio in span 1 of 61 tI %. Design is govemed by bending fblFb. Governing load combination is Dead+Snow Condition 1 w/Pattern Loads. Maximum hanger forces: 3381 Ib (Left) and 3381 Ib (Right). Program Version 8.2 - 912012002 1'1. HEADER#3-Roof Beam Eagle Point Project: GARY CASWELL Job: CASWELL APARTMENTS Page 1 10:51:0702/14/05 Designed by: Donna J. Petersen P.E. Client: CASWELL APARTMENTS Checked by: Input Data Check of 4x10No. 2.DouglaaFlr-l.arch.Dlmenalonal tI Left Cantilever: None Main Span: 5' Check for repetitive use? No Tributary Width: 17'6" Dead Load: 17 psf Live Load: 20 psf Allow. LL Deflection: L/240 Allow. TL Deflection: U180 Eb: 1600000 psi Fy: 180 psi Right Cantilever: None Slope: 0:12 Snow Load: 25 psf DOL: 1.150 Fb: 900 psi Design Checks R..ctJon Bending. X Shear LL Oefl. TL Deft. Ib~~ psi psi In In Max. Value 1837.5 552.228 61.438 -0.0167 -0.028 Allowable 3281.47 1242 207 0.25 0.3333 % of Allow. 56 tI 44t1 30 tI 6t1 8t1 Location 0' 2'6" 9-114" 2'6" 2'6" Reactions and Bearing Support Location It !( Min. Be.rlng In Reaction Ib 0' 5' 1.5 1.5 1837.5 1837.5 Self-weight of member is not included. Member has an actuaVallowable ratio in span 1 of 44 tI %. Design is governed by bending fblFb. Governing load combination is Dead+Snow Condition 1 w/Pattern Loads. Maximum hanger forces: 1837.51b (Left) and 1837.5 Ib (Right). Program Version 8.2 - 9/20/2002 ]9-- - BOISE- BC CALC@ 9 DESIGN REPORT - US Monday, February 14, 2005 10:34 'Single 11 7/8" Bel@ 500-2.0 OF Job Name: Address: City, State, Zip: , Customer: Code reports: ICC ESR (Pending) File Name: BC.bcc: upper floor joists Description: Specifier: Designer: Company: Misc: BO, 1-3/4" LL 400 Ibs DL 170 Ibs General Data Version: US Imperial Member Type: Number of Spans: Left Cantilever: Right Cantilever: Joist 1 No No Slope: OC Spacing: 16" Repetitive: Yes Construction Type: Glued Disclosure . The completeness and accuracy of the input must be verified by anyone who would rely on the output as evidence of suitability for a particular application. The output above is based upon building code-accepted design properties and analysis methods. Installation of BOISE engineered wood products must be in accordance with the current Installation Guide and the applicable building codes. To obtain an Installation Guide or if you have any questions, please call (800)232-0788 before beginning product installation. BC CALC<Il>, BC FRAMER<Il>, BCI<Il>, BC RIM BOARDTM, BC OSB RIM BOARDTM, BOISE GLULAMTM, VERSA-LAM<Il>, VERSA-RIM<Il>, VERSA-RIM PLUS<Il>. VERSA-STRANDTM, VERSA-STUOO, ALLJOIST<Il> and AJSTM are trademarks of Boise Cascade Corporation. Page 1 of 1 Total of Horizontal Design Spans = 15-00-00 Load Summary ID Description Load Type Ref. 1 Standard Load Unf. Area Left Start End Type 00-00-00 16-00-00 Live Dead Value 40 psf 17 psf Controls Summary Control Type Value Pos. Moment 2137 ft-Ibs End Reaction 564 Ibs Total Load Defl. LJ741 (0.243") Live Load Defl. U1056 (0.17") Max Defl. 0.243" Span / Depth 15.2 % Allowable 45.0% 55.1% 32.4% 45.4% 24,3% n/a Duration 100% 100% Load Case 1 1 1 1 1 B1,1-314" LL 400 Ibs DL 170 Ibs OCS 16" 16" Our. 100% 90% Span Location 1 - Internal 1 - Right 1 1 1 1 Notes Design meets Code minimum (U240) Total load deflection criteria. Design meets User specified (U480) Live load deflection criteria. Design meets arbitrary (1") Maximum load deflection criteria. Minimum bearing length for BO is 1-3/4", Minimum bearing length for B1 is 1-314". Entered/Displayed Horizontal Span Length(s) = Clear Span + 1/2 min. end bearing + 1/2 intermediate bearing 10\ 1:_ n_ ~ ~1f!!L...~ T J-Beamlll 6.15 Serial Number: 7003007044 User: 1 2/1410510:40:03 AM Pagel Engine Version: 1.15.33 upper floor joists 11 7/8" TJI@210 @ 16" ole THIS PRODUCT MEETS OR EXCEEDS THE SET DESIGN CONTROLS FOR THE APPLICATION AND LOADS LISTED J HJ~ L ~~ I <' 15' I <' Product Diagram is Conceptual. LOADS: Analysis is for a Joist Member. Primary Load Group - Residential- Living Areas (pst): 40.0 Live at 100 % duration, 17.0 Dead SUPPORTS: Input Width 1 Stud wall 3.50" 2 Stud wall 3.50" Bearing Length 2.25" 2.25" Vertical Reactions (Ibs) Live/Dead/UpIiWTotal 400/170/0/570 400 /170 / 0 / 570 Detail Other A3: Rim Board 1 Ply 1 1/4" x 11 7/8" 0.8E T J-Strand Rim Board~ A3: Rim Board 1 Ply 1 1/4" x 11 7/8" 0.8E T J-Strand Rim Boa~ -See T J SPECIFIER'S / BUILDERS GUIDE for detail(s): A3: Rim Board Shear (Ibs) Vertical Reaction (Ibs) Moment (Ft-Lbs) Live Load Defl (in) Total Load Defl (in) T JPro Design -548 554 2020 0.179 0.255 . 53 Control 1655 1110 3620 0.365 0.729 30 Control Passed (33%) Passed (50%) Passed (56%) Passed (Ll977) Passed (Ll685) Passed Location Rt. end Span 1 under Floor loading Bearing 2 under Floor loading MID Span 1 under Floor loading MID Span 1 under Floor loading MID Span 1 under Floor loading Span 1 -Deflection Criteria: STANDARD(LL:Ll480,TL:Ll240). -Deflection analysis is based on composite action with single layer of 23/32" Panels (24" Span Rating) GLUED & NAILED wood decking. -Bracing(Lu): All compression edges (top and bottom) must be braced at 4' 3" o/c unless detailed otherwise. Proper attachment and positioning of lateral bracing is required to achieve member stability. TJ-Pro RATING SYSTEM -The T J-Pro Rating System value provides additional floor performance information and is based on a GLUED & NAILED 23/32" Panels (24" Span Rating) decking. The controlling span is supported by walls. Additional considerations for this rating include: Ceiling - 5/8" Direct Applied Gypsum Ceiling. A structural analysis of the deck has not been performed by the program. Comparison Value: 1.49 ADDITIONAL NOTES: -IMPORTANT! The analysis presented is output from software developed by Trus Joist (T J). T J warrants the sizing of its products by this software will be accomplished in accordance with T J product design criteria and code accepted design values. The specific product application, input design loads, and stated dimensions have been provided by the software user. This output has not been reviewed by a T J Associate. -Not all products are readily available. Check with your supplier or T J technical representative for product availability. -THIS ANALYSIS FOR TRUS JOIST PRODUCTS ONL YI PRODUCT SUBSTITUTION VOIDS THIS ANALYSIS. -Allowable Stress Design methodology was used for Building Code IBC analyzing the T J Distribution product listed above. PROJECT INFORMATION: Caswell Apt's OPERATOR INFORMATION: 4 Seasons Engineering, Inc. 619 S. Chase St. Port Angeles, WA 98362 Phone: (360) 452-3023 Copyright ~ 2004 by Trus Joist, a Weyerhaeuser Business TJI@ and TJ-Beam@ are registered trademarks of Trus Joist. e-I Joist-,Pro. and TJ-Pro. are trademarks of Trus Joist. "'\~h' nr.,..Il'"An...Q\llo,....."'...."",.....~'rll.~WIi'T,T.'...-\;.;,..;Qt- amc:- '20 I t:l~1!!L__ T J-BeamQ!> 6.15 Serial Number: 7003007044 , User: 1 2/14105 10:40:04 AM Page 2 Engine Version: 1.15.33 upper floor joists 11 7/8" TJI@210 @ 16" ole THIS PRODUCT MEETS OR EXCEEDS THE SET DESIGN CONTROLS FOR THE APPLICATION AND LOADS LISTED Load Group: Primary Load Group 14 I 7.00" Max. Vertical Reaction Total (lbs) 570 Max. Vertical Reaction Live (lbs) 400 Selected Bearing Length (in) 2.25(W) Max. Unbraced Length (in) 51 570 400 2.25(W) Loading on all spans, LDF Design Shear (lbs) Max Shear (lbs) Member Reaction (lbs) Support Reaction (lbs) Moment (Ft-Lbs) 0.90 1.0 163 165 165 170 Dead -163 -165 165 170 603 Loading on all spans, Design Shear (lbs) Max Shear (lbs) Member Reaction (lbs) Support Reaction (lbs) Moment (Ft-Lbs) Live Deflection (in) Total Deflection (in) LDF = 1.00 , 1. 0 Dead + 548 554 554 570 1.0 Floor -548 -554 554 570 2020 0.179 0.255 PROJECT INFORMATION: Caswell Apt's OPERATOR INFORMATION: 4 Seasons Engineering, Inc. 619 S. Chase St. Port Angeles, WA 98362 Phone : (360) 452-3023 Copyright ~ 2004 by Trus Joist, a Weyerhaeuser Business TJI@ and TJ-Beam@ are registered trademarks of Trus Joist. e-I Joist-,Pro. and TJ-Pro. are trademarks of TrUB Joist. r. \Ml1 nn...."mont-q\ lliP"\r.....-\p...t-q\rr.~wJ;'r.T.\ t--\ i -\"i at- C"\llCf 2-( Page 1 lpjoist.dsn LOUISIANA-PACIFIC CORPORATION / WOOD-E DESIGN 2003.1 02/14/05 10:44:41 WARNING *** THIS DESIGN IS VALID FOR THE PROJECT NAMED BELOW (JOB 10) ONLY *** WOOD-E DESIGN 2003.1 EXPIRES ON 12/31/2004. LP WILL MAKE AVAILABLE TO ALL REGISTERED USERS AN UPDATED VERSION OF THE WOOD-E DESIGN SOFTWARE IN THE CONTINUING EFFORT TO MAINTAIN COMPLIANCE WITH CHANGING BUILDING CODES, INDUSTRY PRACTICES, CODE EVALUATION REPORTS AND/OR METHODS OF ANALYSIS. COMPANY: 4 Seasons Engineering, Inc. JOB 10: Caswell Apartments STATE: WA CODE: ICBO PRODUCT: I-PLY 11.875" LPI 20 DESIGN CRITERIA FOR FLOOR JOIST (UNFACTORED LOADS) ------------------------------- LIVE DEAD SAFE LOAD ALLOWABLE ALLOWABLE (PSF) (PSF) LOAD SPACING SHARING SHEATHING LL DEFLECT TL DEFLECT ------- ------- ------------- ---------- ---------- 40 17 NO 16.0 0% GLUED&NAILED L/480 L/360 ALLOWABLE / WORKING STRESS DESIGN DATA DEFLECTION ----------- REACTION MOMENT SHEAR LIVE LOAD TOTAL LOAD ACTUAL ALLOWABLE STRESS INDICES LOAD CASE 570 1025 0.556 1 2102 3406 0.617 1 565 1350 0.419 1 0.190 0.372 L/937 1 0.271 0.496 L/658 1 **** THE REACTION, MOMENT AND SHEAR DATA ABOVE ARE BASED ON THE MAXIMUM STRESS INDICES AND MAY NOT REFLECT THE ABSOLUTE MAXIMUM ACTUALS. **** FOR DEFLECTION, L IS DEFINED AS THE DESIGN SPAN LENGTH OR TWICE THE LENGTH FOR CANTILEVERS. NOTES *** DEFLECTION ASSUMES COMPOSITE ACTION WITH GLUED AND NAILED 19/32" APA RATED SHEATHING (32/16 SPAN RATING) . COMPRESSION EDGE BRACING REQUIRED AT 35" O.C. OR LESS. STRUCTURAL GEOMETRY *** SPAN 1 15.000' TOTAL SPAN: 15.00 FT LOAD PATTERNS (UNFACTORED LOADS) CASE SPAN SHAPE TYPE SOURCE W1 W2 Xl (FT) X2 (FT) +ALL 1 UNIF DEAD FLOOR 22 . 7 PLF 0.000 15.000 +2 1 UNIF LIVE FLOOR 0.0 PLF 0.000 15.000 +1 1 UNIF LIVE FLOOR 53.3 PLF 0.000 15.000 + INDICATES LOAD IS BASED ON SPACING AND INPUT LIVE OR DEAD LOAD PSF. MAXIMUM SECTION FORCES: MOMENT = 2102 FT-LBS SHEAR = 565 LBS 77_ 1-------- Page 2 Ipjoist.dsn MAXIMUM UNFACTORED SUPPORT REACTIONS (LBS) USE THESE VALUES WHEN DESIGNING CONNECTORS BRG#l: 570 BRG#2: 570 MAXIMUM UNFACTORED SUPPORT REACTIONS (PLF) USE THESE VALUES WHEN TRANSFERRING LOADS BRG#!: 428 BRG#2: 428 REQUIRED BEARING SIZES (IN) BRG#l: 1.50 BRG#2: 1.50 LIVE LOAD DEFLC. TOTAL LOAD DEFLC. SPAN ACTUAL ALLOW. L/? ACTUAL ALLOW. L/? 1 0.190 0.372 937 0.271 0.496 658 **** FOR DEFLECTION L IS DEFINED AS DESIGN SPAN LENGTH OR TWICE THE LENGTH FOR CANTILEVERS. MAXIMUM STRESS INDICES: MSI = 0.617 VSI = 0.419 VERIFY YOUR INPUT TO AVOID DESIGN AND FABRICATION MISTAKES. YOU ARE SOLELY RESPONSIBLE FOR ERRORS RESULTING FROM INCORRECT INPUT. THIS PROGRAM IS A DESIGN TOOL AND SHOULD BE USED WITH EXTREME CARE THAT INPUT UNIFORM AND CONCENTRATED LOADS ARE ACCURATE IN MAGNITUDE AND LOCATION. IF YOU HAVE ANY QUESTIONS OR UNCERTAINTIES, PLEASE CONTACT LP. THIS COMPONENT DESIGN IS SPECIFICALLY FOR LP ENGINEERED WOOD PRODUCTS. USE OF THIS PROGRAM TO DESIGN ANYTHING OTHER THAN GANG-LAM LVL, OR LPI-JOISTS IS STRICTLY PROHIBITED. LP IS A TRADEMARK OF LOUISIANA-PACIFIC CORPORATION -;~ :2., - BOISEN BC CALC@ 9 DESIGN REPORT - US Monday, February 14, 2005 10:34 -Double 1 3/4" x 11 7/8" VERSA-LAM@ 2.02800 Job Name: Address: City, State, Zip: , Customer: Code reports: ESR-1040 File Name: BC.bcc: FB#1 Description: Specifier: Designer: Company: Mise: BO LL 2040 Ibs DL 931 Ibs General Data Version: US Imperial Member Type: Number of Spans: Left Cantilever: Right Cantilever: Floor Beam 1 No No Slope: Disclosure The completeness and accuracy of the input must be verified by anyone who would rely on the output as evidence of suitability for a particular application. The output above is based upon building code-accepted design properties and analysis methods. Installation of BOISE engineered wood products must be in accordance with the current Installation Guide and the applicable building codes. To obtain an Installation Guide or if you have any questions, please call (800)232-0788 before beginning product installation. BC CALC@, BC FRAMER@, BCI@, BC RIM BOARDTM, BC OSB RIM BOARDTM, BOISE GLULAMTM, VERSA-LAMilll, VERSA-RIM@, VERSA-RIM PLUS@, VERSA-STRANDTM , VERSA-STUDilll, ALLJOIST@ and AJS ™ are trademarks of Boise Cascade Corporation. Page 1 of 1 Total of Horizontal Design Spans = 12-00-00 Load Summary ID Description Load Type Ref. 1 Standard Load Unf. Area Left Start End 00-00-00 12-00-00 Type Live Dead Value 40 psf 17 psf Controls Summary Control Type Value Pos. Moment 8913 ft-Ibs Neg. Moment -0 ft-Ibs End Shear 2445 Ibs Total Load Detl. U609 (0.237") Live Load Defl. U887 (0.162") Max Defl. 0.237" Span / Depth 12.1 % Allowable 46.4% n/a 31.0% 39.4% 40.6% 23.7% n/a Duration 100% 100% 100% Load Case 1 1 1 1 1 1 B1 LL 2040 Ibs DL 9311bs Trib. Our. 08-06-00 100% 08-06-00 90% Span Location 1 - Internal 1 - Right 1 - Left 1 1 1 1 Notes Design meets Code minimum (U240) Total load deflection criteria. Design meets Code minimum (U360) Live load deflection criteria. Design meets arbitrary (1") Maximum load deflection criteria. Minimum bearing length for BO is 1-1/2". Minimum bearing length for 81 is 1-1/2". Entered/Displayed Horizontal Span Length(s) = Clear Span + 1/2 min. end bearing + 1/2 intermediate bearing Connection Diagram Consult project design professional of record or BOISE technical representative for connection design Connectors are: 16d Sinker Nails a minimum = 2" b minimum = 3" c = 7-7/8" d = 12" Db a . r. c .J_ . ~ . 24. FB#2-Floor Beam Eagle Point Project: GARY CASWELL Job: CASWELL APARTMENTS Page 1 10:51 :45 02/14/05 Designed by: Donna J. Petersen P.E. Client: CASWELL APARTMENTS Checked by: Input Data Check of 4x10 No. 2-Douglaa Fir-Larch-Dimenslonal " Left Cantilever: None Main Span: 9'6" Check for repetitive use? No Tributary Width: 2'6" Dead Load: 17 psf Live Load: 100 psf Allow. LL Deflection: U360 Allow. TL Deflection: U240 (3 in Maximum) Eb: 1600000 psi Fy: 180 psi Right Cantilever: None Slope: 0 Snow Load: 0 DOL: 1.000 Fb: 900 psi Design Checks Reaction Bending. X Shear LL Oefl. TL Deft. Ib ptl pal In In Max. Value 1389.38 793.349 55.169 -0.124 -0.1451 Allowable 3281.47 1080 180 0.3167 0.475 % of Allow. 42 " 73 tI 31 tI 39 tI 30 " Location 0' 4'9" 9-1/4" 4'9" 4'9" Reactions and Bearing Support Location ft MIn. BearIng In Reaction Ib 0' 9'6" 1.5 1.5 1389.38 1389.38 Self-weight of member is not included. Member has an actuaVallowable ratio in span 1 of 73 " %. Design is governed by bending fbIFb. Governing load combination is Dead+Floor Live w/Patlern Loads. Maximum hanger forces: 1389.38 Ib (Left) and 1389.38 Ib (Right). Program Version 8.2 - 912012002 2.< BALCONY JOIST-Floor Beam Eagle Point Project: GARY CASWELL Job: CASWELL APARTMENTS Page 1 10:52:0402/14/05 Designed by: Donna J. Petersen P.E. Client: CASWELL APARTMENTS Checked by: Input Data Design of 2x8 No.2-Douglas Fir-Larch-Dlmensional tI Left Cantilever: None Main Span: 5' Check for repetitive use? Yes Tributary Width: 1'4" Dead Load: 17 psf Live Load: 100 psf Allow. LL Deflection: U360 Allow. TL Deflection: U240 (3 in Maximum) Eb: 1600000 psi Fv: 180 psi Right Cantilever: None Slope: 0 Snow Load: 0 DOL: 1.000 Fb: 900 psi Design Checks Reaction Bending - X Shear LL Deft. TL Defl. Ib psi pal In In Max. Value 390 445.184 42.486 -0.0246 -0.0288 Allowable 1406.34 1242 180 0.1667 0.25 % of Allow. 28 tI 36 tI 24 tI 14 tI 11t1 Location 0' 2'6" 7-1/4" 2'6" 2'6" Reactions and Bearing Support Location It Min. Bearing In Reaction Ib 0' 5' 1.5 1.5 390 390 Self-weight of member is not included. Member has an actuaVallowable ratio in span 1 of 36 tI %. Design is governed by bending fb/Fb. Governing load combination is Dead+Floor Live w/Pattern Loads. Maximum hanger forces: 390 Ib (Left) and 390 Ib (Right). Program Version 8.2 - 912012002 2(." ~- ---- I BOisEN BC CALC@ 9 DESIGN REPORT - US Monday, February 14, 2005 10:34 Single 11 7/8" Bel@ 500-2.0 OF Job Name: Address: City, State, Zip: , Customer: Code reports: ICC ESR (Pending) File Name: BC.bcc: cantilever floor joists Description: Specifier: Designer: Company: Misc: 80,1-314" LL 240 Ibs DL 79 Ibs General Data Version: US Imperial Member Type: Number of Spans: Left Cantilever: Right Cantilever: Joist 2 No Ves Slope: OC Spacing: 12" Repetitive: Ves Construction Type: Glued Disclosure The completeness and accuracy of the input must be verified by anyone who would rely on the output as evidence of suitability for a particular application. The output above is based upon building code-accepted design properties and analysis methods. Installation of BOISE engineered wood products must be in accordance with the current Installation Guide and the applicable building codes. To obtain an Installation Guide or if you have any questions, please call (800)232-0788 before beginning product installation. BC CALC@, BC FRAMER@, BCI@, BC RIM BOARDTM, BC OSB RIM BOARDTM, BOISE GLULAMTM, VERSA-LAM@, VERSA-RIM4ll, VERSA-RIM PLUS@, VERSA-STRANDTM, VERSA-STUD@, ALLJOIST@ and AJSTM are trademarks of Boise Cascade Corporation. Page 1 ot 1 81,3-112" LL 893 Ibs DL 2611bs Total of Horizontal Design Spans = 16-00-00 Load Summary 10 Description Load Type Ref. Start End 1 Standard Load Unf. Area Left 00-00-00 16-00-00 Type Live Dead Live Dead Value 40 pst 17 psf 100 psf 17 psf 2 BALCONY LOAUnf. Area Left 12-00-00 16-00-00 Controls Summary Control Type Value Pos. Moment 895 ft-Ibs Neg. Moment -1392 ft-Ibs End Reaction 3151bs Int. Reaction 1120 Ibs Cont. Shear 671 Ibs Uplift 141bs Total Load Defl. 2xU800 (0.12") Live Load Defl. 2xU847 (0.113") Total Neg. Defl. -0.047" Max Defl. 0.12" Span / Depth 12.1 % Allowable 18.8% 29.3% 30.7% 48.2% 41.3% nla 22.5% 56.7% 9.4% 12.0% n/a Duration 100% 100% 100% 100% 100% Load Case 13 15 13 1 1 15 15 15 13 15 Cautions Design assumes Top and Bottom flanges to be restrained at cantilever. OCS 12" 12" 12" 12" Our. 100% 90% 100% 90% Span Location 1 - Internal 1 - Right 1 - Left 2 - Left 2 - Left 1 - Left 2 - Cantilever 2 - Cantilever 2 - Cantilever 2 - Cantilever 1 Notes Design meets Code minimum (2xU180) Total load deflection criteria. Design meets Code minimum (2xU240) Live load deflection criteria. Design meets arbitrary (1") Maximum load deflection criteria. Minimum bearing length for BO is 1-3/4". Minimum bearing length for B1 is 3-1/2". Entered/Displayed Horizontal Span Length(s) = Clear Span + 1/2 min. end bearing + 1/2 intermediate bearing 2":/ ~~l~...= T J-Beam4!l6.15 Serial Number. 7003007044 User: 1 2/14/0510:42:44 AM Page 1 Engine Version: 1.15.33 cantilever floor joists 11 7/8" TJI@ 210 @ 16" olc THIS PRODUCT MEETS OR EXCEEDS THE SET DESIGN CONTROLS FOR THE APPLICATION AND LOADS LISTED Overall Dimension: 16' L ~ ~g] J I <> 12' I ~ I I 4' ----6 Product Diagram is Conceptual. LOADS: Analysis is for a Joist Member. Primary Load Group - Residential- Living Areas (pst): 40.0 Live at 100 % duration, 17.0 Dead Vertical Loads: Type Class Live Dead Location Application Comment Uniform(pst) Floor(1.00) 100.0 17.0 12' To 16' Replaces SUPPORTS: Input Width 1 Stud wall 3.50" 2 Stud wall 3.50" Bearing Length 2.25" 3.50" Vertical Reactions (Ibs) Live/Dead/UpliWTotal 322 1120 I 0 I 442 950 I 243 I 0 11193 Detail Other A3: Rim Board E1: Blocking 1 Ply 1 1/4" x 11 7/8" 0.8E T J-Strand Rim Board~ 1 Ply117/8"TJI~210 -See T J SPECIFIER'S I BUILDERS GUIDE for detail(s): A3: Rim Board,E1: Blocking DESIGN CONTROLS: Shear (Ibs) Vertical Reaction (Ibs) Moment (Ft-Lbs) Live Load Detl (in) Total Load Defl (in) T JPro Maximum 624 1193 -1340 Design 624 1193 -1340 0.114 0.103 61 Control 1821 2145 2715 0.207 0.415 30 Control Passed (34%) Passed (56%) Passed (49%) Passed (2U871) Passed (2U962) Passed Location Right OH under Floor loading Bearing 2 under Floor loading Bearing 2 under Floor loading Right OH under Floor ALTERNATE span loading Right OH under Floor ALTERNATE span loading Span 1 .Deflection Criteria: STANDARD(LL:U480,TL:L1240). -Permanent bracing at third points in the back span or a direct applied ceiling over the entire back span length is required for right cantilever. See literature detail (PB1) for clarification. -Deflection analysis is based on composite action with single layer of 23/32" Panels (24" Span Rating) GLUED & NAILED wood decking. -Bracing(Lu): All compression edges (top and bottom) must be braced at 5' 2" olc unless detailed otherwise. Proper atta.chment and positioning of lateral bracing is required to achieve member stability. -The load conditions considered in this design analysis include alternate member pattern loading. TJ-Pro RATING SYSTEM .The T J.Pro Rating System value provides additional floor performance information and is based on a GLUED & NAILED 23/32" Panels (24" Span Rating) decking. The controlling span is supported by walls. Additional considerations for this rating include: Ceiling - 5/8" Direct Applied Gypsum Ceiling. A structural analysis of the deck has not been performed by the program. Comparison Value: 1.49 PROJECT INFORMATION: Caswell Apt's OPERATOR INFORMATION: 4 Seasons Engineering, Inc. 619 S. Chase St. Port Angeles, WA 98362 Phone: (360) 452-3023 Copyright €:I 2004 by Trus Joist, a Weyerhaeuser Business TJI@ and TJ-Beam@ are registered trademarks of Trus Joist. e-I Joist., Pro. and TJ-Pro. are trademarks of Trus Joist. r.\),I" """f'""MP"'..Cl\Zl.nrn"iQ,....c::\rac::W1:"T.T.\,."'......;lPHor h,.l,......"H 0:."'0 2Q. ~ ~l!!!l..- T J.Bea~ 6.15 Serial Number: 7003007044 Usar. 1 2/1410510:42:46 AM Page 3 Engine Version: 1.15.33 cantilever floor joists 11 7/8" TJI@ 210 @ 16" ole THIS PRODUCT MEETS OR EXCEEDS THE SET DESIGN CONTROLS FOR THE APPLICATION AND LOADS LISTED Load Group: Primary Load Group II' 7.75" 4' 1. 75" Max. Vertical Reaction Total (lbs) 442 Max. Vertical Reaction Live (lbs) 322 Selected Bearing Length (in) 2.25(W) Max. Unbraced Length (in) 66 Loading on all spans, Design Shear (lbs) Max Shear (lbs) Member Reaction (lbs) Support Reaction (lbs) Moment (Ft-Lbs) Loading on all spans, LDF Design Shear (lbs) Max Shear (lbs) Member Reaction (lbs) Support Reaction (lbs) Moment (Ft-Lbs) Live Deflection (in) Total Deflection (in) ALTERNATE span loading Design Shear (lbs) Max Shear (lbs) Member Reaction (lbs) Support Reaction (lbs) Moment (Ft-Lbs) Live Deflection (in) Total Deflection (in) on odd II ALTERNATE span loading Design Shear (lbs) Max Shear (lbs) Member Reaction (lbs) Support Reaction (lbs) Moment (Ft-Lbs) Live Deflection (in) Total Deflection (in) 1193 950 3.50 (W) 62 62 LDF = 0.90 , 1. 0 Dead 113 -129 91 115 -149 91 115 243 120 243 293 -195 0 1.00 , 1.0 Dead + 1.0 Floor' 321 -485 624 327 -558 624 327 1193 343 1193 706 -1340 0.025 0.048 spans, LDF 419 426 426 442 on even II spans, LDF 15 17 PROJECT INFORMATION: Caswell Apt's 17 22 Copyright \Q 2004 by Trus Joist, a Weyerhaeuser Business TJI@ and TJ-Bea~ are registered trademarks of Trus Joist. e-I JOi9t~,Pro- and TJ-Pro. are trademarks of Trus Joist. "'\UH rv......"""Gn..Q\ll,......,....i""'....t-ct\rac::W1i'T,T.\r:on..i l....n..... h::01,......",, CI"'''' N/A 0.043 0.032 1. 00 1. 0 -398 91 -459 91 553 553 -195 Dead + 1.0 Floor 1193 0.079 0.102 o -0.071 -0.082 1.00 1.0 Dead + 1.0 Floor -216 624 -247 624 882 882 -1340 6 -0.061 -0.041 N/A 0.114 0.103 OPERATOR INFORMATION: 4 Seasons Engineering, Inc. 619 S. Chase St. Port Angeles, WA 98362 Phone: (360) 452-3023 '2<='\ ,~- ~ q;;".,1!!!L..- T J-Be~ 6.15 Seriel Number: 7003007044 . User: 1 2/14/05 10:42:45 AM Page 2 Engine Version: 1.15.33 cantilever floor joists 11 7/8" TJI@210 @ 16" ole THIS PRODUCT MEETS OR EXCEEDS THE SET DESIGN CONTROLS FOR THE APPLICATION AND LOADS LISTED ADDITIONAL NOTES: -IMPORTANT! The analysis presented is output from software developed by Trus Joist (T J). T J warrants the sizing of its prOducts by this software will be accomplished in accordance with T J product design criteria and code accepted design values. The specific product application, input design loads, and stated dimensions have been provided by the software user. This output has not been reviewed by a T J Associate. -Not all products are readily available. Check with your supplier or T J technical representative for product availability. -THIS ANALYSIS FOR TRUS JOIST PRODUCTS ONL YI PRODUCT SUBSTITUTION VOIDS THIS ANALYSIS. -Allowable Stress Design methodology was used for Building Code IBC analyzing the T J Distribution product listed above. -Permanent bracing at third points in the back span or a direct applied ceiling over the entire back span length is required for right cantilever. See literature detail (PB1) for clarification. PROJECT INFORMATION: Caswell Apt's OPERATOR INFORMATION: 4 Seasons Engineering, Inc. 619 S. Chase SI. Port Angeles, WA 98362 Phone: (360) 452-3023 Copyright ~ 2004 by Teus Joist, a Weyerhaeuser Business TJI~ and TJ-Beam@ are registered trademarks of Trus Joist. e-I Joist-,Pro. and TJ-Pro. are trademarks of Trus Joist. r. \ u" nr.,..","cnt-c:r\ Ilonrn-i crot- c:r\ rIloO:::W,",T,T.\ ,...:lint- i 1 CIo'":.''' "':0 1 ,..nn" <lft'lc: 2/'1 Page 1 lp cantilever joist.dsn -LOUISIANA-PACIFIC CORPORATION / WOOD-E DESIGN 2003.1 02/14/05 10:48:22 WARNING *** THIS DESIGN IS VALID FOR THE PROJECT NAMED BELOW (JOB ID) ONLY *** WOOD-E DESIGN 2003.1 EXPIRES ON 12/31/2004. LP WILL MAKE AVAILABLE TO ALL REGISTERED USERS AN UPDATED VERSION OF THE WOOD-E DESIGN SOFTWARE IN THE CONTINUING EFFORT TO MAINTAIN COMPLIANCE WITH CHANGING BUILDING CODES, INDUSTRY PRACTICES, CODE EVALUATION REPORTS AND/OR METHODS OF ANALYSIS. COMPANY: 4 Seasons Engineering, Inc. JOB ID: Caswell Apartments STATE: WA CODE: ICBO PRODUCT: I-PLY 11.875" LPI 20 DESIGN CRITERIA FOR FLOOR JOIST (UNFACTORED LOADS) LIVE DEAD SAFE LOAD (PSF) (PSF) LOAD SPACING SHARING SHEATHING ALLOWABLE ALLOWABLE LL DEFLECT TL DEFLECT 40 17 NO 16.0 0% GLUED&NAILED L/480 L/360 ALLOWABLE / WORKING STRESS DESIGN DATA DEFLECTION ----------- REACTION MOMENT SHEAR LIVE LOAD TOTAL LOAD ACTUAL ALLOWABLE STRESS INDICES LOAD CASE 1184 2350 0.504 1 1247 3406 0.366 1 624 1350 0.462 1 0.103 0.200 L/935 4 0.107 0.393 L/1323 3 **** THE REACTION, MOMENT AND SHEAR DATA ABOVE ARE BASED ON THE MAXIMUM STRESS INDICES AND MAY NOT REFLECT THE ABSOLUTE MAXIMUM ACTUALS. **** FOR DEFLECTION, L IS DEFINED AS THE DESIGN SPAN LENGTH OR TWICE THE LENGTH FOR CANTILEVERS. NOTES *** DEFLECTION ASSUMES COMPOSITE ACTION WITH GLUED AND NAILED 19/32" APA RATED SHEATHING (32/16 SPAN RATING). *** COMPRESSION EDGE BRACING REQUIRED AT 48" O.C. OR LESS. STRUCTURAL GEOMETRY SPAN 1 RIGHT CANT 12.000' 4.000' TOTAL SPAN: 16.00 FT LOAD PATTERNS (UNFACTORED LOADS) ------------- CASE SPAN SHAPE TYPE SOURCE WI W2 Xl (FT) X2 (FT) ------ ------ ------------ ------------ ------- ------- +ALL 1 UNIF DEAD FLOOR 22.7 PLF 0.000 12.000 +2 1 UNIF LIVE FLOOR 0.0 PLF 0.000 12.000 +ALL R UNIF DEAD FLOOR 22.7 PLF 0.000 4.000 +2 R UNIF LIVE FLOOR 0.0 PLF 0.000 4.000 +1 1 UNIF LIVE FLOOR 53.3 PLF 0.000 12.000 '2 - .~) I Page 2 lp cantilever joist.dsn 1 +1 R R UNIF LIVE UNIF LIVE FLOOR FLOOR 80.0 PLF 53.3 PLF 0.000 0.000 4.000 4.000 +3 1 UNIF LIVE FLOOR 53.3 PLF 0.000 12.000 4 R UNIF LIVE FLOOR 80.0 PLF 0.000 4.000 +4 R UNIF LIVE FLOOR 53.3 PLF 0.000 4.000 + INDICATES LOAD IS BASED ON SPACING AND INPUT LIVE OR DEAD LOAD PSF. MAXIMUM SECTION FORCES: MOMENT = 1247 FT-LBS SHEAR = 624 LBS MAXIMUM UNFACTORED SUPPORT REACTIONS (LBS) USE THESE VALUES WHEN DESIGNING CONNECTORS BRG#l: 441 BRG#2: 1184 MAXIMUM UNFACTORED SUPPORT REACTIONS (PLF) USE THESE VALUES WHEN TRANSFERRING LOADS BRG#l: 331 BRG#2: 888 REQUIRED BEARING SIZES (IN) BRG#l: 1.50 BRG#2: 3.50 LIVE LOAD DEFLC. TOTAL LOAD DEFLC. SPAN ACTUAL ALLOW. L/? ACTUAL ALLOW. L/? 1 R 0.082 0.103 0.295 1736 0.107 0.200 935 0.090 0.393 1323 0.267 1063 **** FOR DEFLECTION L IS DEFINED AS DESIGN SPAN LENGTH OR TWICE THE LENGTH FOR CANTILEVERS. MAXIMUM STRESS INDICES: MSI = 0.366 VSI = 0.462 VERIFY YOUR INPUT TO AVOID DESIGN AND FABRICATION MISTAKES. YOU ARE SOLELY RESPONSIBLE FOR ERRORS RESULTING FROM INCORRECT INPUT. THIS PROGRAM IS A DESIGN TOOL AND SHOULD BE USED WITH EXTREME CARE THAT INPUT UNIFORM AND CONCENTRATED LOADS ARE ACCURATE IN MAGNITUDE AND LOCATION. IF YOU HAVE .ANY QUESTIONS OR UNCERTAINTIES, PLEASE CONTACT LP. THIS COMPONENT DESIGN IS SPECIFICALLY FOR LP ENGINEERED WOOD PRODUCTS. USE OF THIS PROGRAM TO DESIGN ANYTHING OTHER THAN GANG-LAM LVL, OR LPI-JOISTS IS STRICTLY PROHIBITED. LP IS A TRADEMARK OF LOUISIANA-PACIFIC CORPORATION .:?:: 7_ ---- -----, HEADER#4-Floor Beam Eagle Point Project: GARY CASWELL Job: CASWELL APARTMENTS Page 1 10:54:3302/14/05 Designed by: Donna J. Petersen P.E. Client: CASWELL APARTMENTS Checked by: Input Data Check of 4x10 No.2-Douglas Flr-Larch-Dlmenslonal tI Left Cantilever: None Main Span: 6' Check for repetitive use? No Tributary Width: 5'6" Dead Load: 17 psf Live Load: 40 psf Allow. LL Deflection: U360 Allow. TL Deflection: U240 (3 in Maximum) Eb: 1600000 psi F.: 180 psi Right Cantilever: None Slope: 0 Snow Load: 0 DOL: 1.000 Fb: 900 psi User Defined Loads Load Ca.. Load Dlatance(a) to Load Load at Load at Type Start Length Start End ft ft pit plf Dead Uniform 0' 6' 42.5 Floor Live Uniform 0' 6' 250 Design Checks Reaction Bending - X Shear LL Defl. TL Defl. Ib pal pel In In Max. Value 1818 655.641 63.287 -0.0371 -0.0478 Allowable 3281.47 1080 180 0.2 0.3 % of Allow. 55 tI 61 tI 35 tI 18 tI 15 tI Location 0' 3' 5'2-3/4" 3' 3' Reactions and Bearing Support Location ft Min. Bearing In Reaction Ib 0' 6' 1.5 1.5 1818 1818 Self-weight of member is not included. Member has an actuaVallowable ratio in span 1 of 61 tI %. Design is governed by bending fblFb. Governing load combination is Dead+Floor Live w/Pattern Loads. Maximum hanger forces: 18181b (Left) and 18181b (Right). Program Version 8.2 - 9120/2002 33 L- .. HEADER#5-Quick Beam " Eagle Point Project: GARY CASWELL Job: CASWELL APARTMENTS Page 1 10:55:0602/14/05 Designed by: Donna J. Petersen P.E. Client: CASWELL APARTMENTS Checked by: Input Data Design of 4x10 No.2-Douglas Fir-larch-Dimensional tI Left Cantilever: None Main Span: 5' Check for repetitive use? No Tributary Width: 0' Dead Load: 0 psf Live Load: 0 psf Allow. LL Deflection: U360 Allow. TL Deflection: U240 (3 in Maximum) Eb: 1600000 psi Fy: 180 psi Right Cantilever: None Slope: 0 Snow Load: 0 DOL: 1.000 Fb: 900 psi User Defined Loads Load ease Load Dlstance(s) to Load Load at Load at Type Start Length Start End ft ft plf plf Dead Uniform 0' 5' 261 Floor Live Uniform 0' 5' 893 Design Checks Reaction BendIng - X Shear LL Defl. TL Deft. Ib psI psI In In Max. Value 2885 867.035 92.454 -0.034 -0.0439 Allowable 3281.47 1080 180 0.1667 0.25 % of Allow. 88 tI 80 tI 51 tI 20 tI 17t1 Location 0' 2'6" 4'2-3/4" 2'6" 2'6" Reactions and Bearing Support location ft MIn. BearIng In Reaction Ib 0' 5' 1.5 1.5 2885 2885 Self-weight of member is not included. Member has an actuaVallowable ratio in span 1 of 80 tI %. Design is governed by bending fblFb. Governing load combination is Dead+Floor Live. Maximum hanger forces: 2885 Ib (Left) and 2885 Ib (Right). Program Version 8.2 - 9120/2002 .~4 - "ISEN BC CALC@ 9 DESIGN REPORT - US Monday, February 14, 2005 10:34 Single 9 1/2" Bel@ 450-1.9 OF Job Name: Address: City, State, Zip: , Customer: Code reports: ICC ESR (Pending) File Name: BC.bcc: lower level joists Description: Specifier: Designer: Company: Misc: ~~-o BO,1-3/4" LL 320 Ibs DL 1361bs General Data Version: US Imperial Member Type: Number of Spans: Left Cantilever: Right Cantilever: Joist 1 No No Slope: OC Spacing: 16" Repetitive: Yes Construction Type: Glued Disclosure The completeness and accuracy of the input must be verified by anyone who would rely on the output as evidence of suitability for a particular application. The output above is based upon building code-accepted design properties and analysis methods. Installation of BOISE engineered wood products must be in accordance with the current Installation Guide and the applicable building codes. To obtain an Installation Guide or if you have any questions, please call (800)232-0788 before beginning product installation. BC CALClfj), BC FRAMERlfj), BCIlfj), BC RIM BOARDTM, BC OSB RIM BOARDTM, BOISE GLULAMTM, VERSA-LAMlfj), VERSA-RIM@, VERSA-RIM PLUS@, VERSA-STRANDTM, VERSA-STUOO, ALLJOIST@ and AJSTM are trademarks of Boise Cascade Corporation. Page 1 of 1 Total of Horizontal Design Spans = 12-00-00 Load Summary 10 Description Load Type Ref. 1 Standard Load Unf. Area Left Controls Summary Control Type Value Pos. Moment 1368 ft-Ibs End Reaction 450 Ibs Total Load Defl. L/750 (0.192") Live Load Defl. U1068 (0.135") Max Defl. 0.192" Span I Depth 15.2 Start End Type 00-00-00 12-00-00 Live Dead Value 40 psf 17 psf B1,1-3/4" LL 320 Ibs DL 136 Ibs DCS 16" 16" Our. 100% 90% % Allowable 47.1% 43.9% 32.0% 44.9% 19.2% nla Duration 100% 100% Load Case 1 1 1 1 1 Span Location 1 - Internal 1 - Left 1 1 1 1 Notes Design meets Code minimum (U240) Total load deflection criteria. Design meets User specified (U480) Live load deflection criteria. Design meets arbitrary (1") Maximum load deflection criteria. Minimum bearing length for BO is 1-3/4". Minimum bearing length for B1 is 1-3/4". EnteredlDisplayed Horizontal Span Length(s) = Clear Span + 1/2 min. end bearing + 1/2 intermediate bearing ~5 .:l ~lmt -, ""0' l"'ts : ,_",.....~...... 91/2" TJI@110@ 16" ole User: 1 2/1410510.43:55 AM Page 1 Engine Version' 1.1533 THIS PRODUCT MEETS OR EXCEEDS THE SET DESIGN CONTROLS FOR THE APPLICATION AND LOADS LISTED J [!]~ L ~~ I ~ 12' I " Produd Diagram is Conceptual. LOADS: Analysis is for a Joist Member. Primary Load Group - Residential- Living Areas (pst): 40.0 Live at 100 % duration, 10.0 Dead SUPPORTS: Input Bearing Vertical Reactions (Ibs) Detail Other Width Length Live/Dead/UpliftIT otal 1 Stud wall 3.50" 2.25" 320/80/0/400 A3: Rim Board 1 Ply 1 1/4" x 91/2" 0.8E TJ-Strand Rim Boardlll> 2 Stud wall 3.50" 2.25" 320/80/0/400 A3: Rim Board 1 Ply 1 1/4" x 9 1/2" 0.8E T J-Strand Rim Boardlll> -See T J SPECIFIER'S 1 BUILDERS GUIDE for detail(s): A3: Rim Board DESIGN CONTROLS: Shear (Ibs) Vertical Reaction (Ibs) Moment (Ft-Lbs) Live Load Defl (in) Total Load Defl (in) TJPro Maximum 386 386 1118 Design -381 386 1118 0.139 0.174 46 Control 1220 1018 2380 0.290 0.579 30 Control Passed (31%) Passed (38%) Passed (47%) Passed (U999+) Passed (U800) Passed Location Rt. end Span 1 under Floor loading Bearing 2 under Floor loading MID Span 1 under Floor loading MID Span 1 under Floor loading MID Span 1 under Floor loading Span 1 -Deflection Criteria: STANDARD(LL:U480,TL:U240). -Deflection analysis is based on composite action with single layer of 19/32" Panels (20" Span Rating) GLUED & NAILED wood decking. -Bracing(Lu): All compression edges (top and bottom) must be braced at 3' 10" o/c unless detailed otherwise. Proper attachment and positioning of lateral bracing is required to achieve member stability. TJ-Pro RATING SYSTEM -The T J-Pro Rating System value provides additional floor performance information and is based on a GLUED & NAILED 19/32" Panels (20" Span Rating) decking. The controlling span is supported by walls. Additional considerations for this rating include: Ceiling - None. A structural analysis of the deck has not been performed by the program. Comparison Value: 1.22 ADDITIONAL NOTES: -IMPORTANTI The analysis presented is output from software developed by Trus Joist (T J). T J warrants the sizing of its products by this software will be accomplished in accordance with T J product design criteria and code accepted design values. The speCific product application, input design loads, and stated dimensions have been provided by the software user. This output has not been reviewed by a T J Associate. -Not all products are readily available. Check with your supplier or T J technical representative for product availability. -THIS ANALYSIS FOR TRUS JOIST PRODUCTS ONL YI PRODUCT SUBSTITUTION VOIDS THIS ANALYSIS. -Allowable Stress Design methodology was used for Building Code IBC analyzing the T J Distribution product listed above. PROJECT INFORMATION: Caswell Apt's OPERATOR INFORMATION: 4 Seasons Engineering, Inc. 619 S. Chase St. Port Angeles, WA 98362 Phone: (360) 452-3023 Copyright ~ 2004 by Trus Joist, a Weyerhaeuser Business TJltEI and TJ-Bean0 are registered trademarks of Trua Joist. e-I Joist-,Pro~ and TJ-Pro. are trademarks of Trus Joist. r.\}.,(u nn...."m""".."'\Zl.nr'...ia.rot-Cl\rZl.<::WlO'Y.T.\T.f'lW...'A T...."...T. .TnT<::'T't:: Qm<: -3<0 r---- ...~ ~'N;~~ lower level joists " ~~~~rBUSjn= 91/2" TJIIS\ 110 @ 16" 1 ! T J-Beemll!l6.15 Seriel Number: 7003007044 \01 0 C User: 1 2/14/05 10 43:56 AM Page2 EnglneVersion 1.15.33 THIS PRODUCT MEETS OR EXCEEDS THE SET DESIGN CONTROLS FOR THE APPLICATION AND LOADS LISTED Load Group: Primary Load Group II' 7.00" Max. Vertical Reaction Total (lbs) 400 Max. Vertical Reaction Live (lbs) 320 Selected Bearing Length (in) 2.25(W) Max. Unbraced Length (in) 46 400 320 2.25 (W) Loading on all spans, LDF Design Shear (lbs) Max Shear (lbs) Member Reaction (lbs) Support Reaction (lbs) Moment (Ft-Lbs) 0.90 1. 0 Dead 76 -76 77 -77 77 80 77 80 224 Loading on all spans, Design Shear (lbs) Max Shear (lbs) Member Reaction (lbs) Support Reaction (lbs) Moment (Ft-Lbs) Live Deflection (in) Total Deflection (in) LDF 1. 00 , 1. 0 Dead + 381 386 386 400 1 . 0 Floor -381 -386 386 400 1118 0.139 0.174 PROJECT INFORMATION: Caswell Apt's OPERATOR INFORMATION: 4 Seasons Engineering, Inc. 619 S. Chase St. Port Angeles, WA 98362 Phone : (360) 452-3023 Copyright @ 2004 by Trus Joist, a Weyerhaeuser Business TJI@ and TJ-Beam@ are registered trademarks of Trus Joist. e-I Joist-,Pro- and TJ-Pro. are trademarks of Trus Joist. ro. \U" T'IrI,...'H..,ant'"<=\ lh'.r'n-l o.........c::r \ ("''aC:::W1O''T.T.\ T.nW1O"l) 1...."1;'1, .TATC:::'Y'C::: ",me ~-=t- r . .t' CRAWL SPACE BEAM-Quick Beam t Eagle Point Project: GARY CASWELL Job: CASWELL APARTMENTS Page 1 10:55:2902/14/05 Designed by: Donna J. Petersen P.E. Client: CASWELL APARTMENTS Checked by: Input Data Check of 4x8 No. 2-Douglas Flr-Larch-Dlmenslonal " Left Cantilever: None Main Span: 6' Check for repetitive use? No Tributary Width: 0' Dead Load: 0 psf Live Load: 0 psf Allow. LL Deflection: LJ360 Allow. TL Deflection: LJ240 (3 in Maximum) Eb: 1600000 psi Fv: 180 psi Right Cantilever: None Slope: 0 Snow Load: 0 DOL: 1.000 Fb: 900 psi User Defined Loads Load Case Load Dlat8nce(s) to Load Load at Load at Type Start Length Start End ft ft plf plf Dead Unifonn 0' 3' 100 Floor Live Unifonn 0' 3' 400 Dead Unifonn 3' 3' 75 Floor Live Unifonn 3' 3' 300 Design Checks Reaction Bending. X Shear LL Dtfl. TL Defl. Ib pal pal In In Max. Value 1406.25 773.951 65.271 -0.0574 -0.0717 Allowable 3281.47 1170 180 0.2 0.3 % of Allow. 43 " 66 " 36 " 28 " 23 " Location 0' 2'9-3/4" 7-1/4" 2'11-9/16" 2'11-9/16" Reactions and Bearing Support Location ft ,Min. Bearing In Reaction Ib O' 6' 1.5 1.5 1406.25 1218.75 Self-weight of member is not included. Member has an actuaVallowable ratio in span 1 of 66 "%. Design is governed by bending fb/Fb. . Governing load combination is Dead+Floor Live. Maximum hanger forcas: 1406.25Ib (Left) and 1218.751b (Right). Program Version 8.2 - 9/20/2002 ~~