Loading...
HomeMy WebLinkAbout939 Caroline St Technical - BuildingE'1'CIIN-,,-ICAL tqC0 Fe & Building Products Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 -com Customer Service/Sales: Tel: (414) 570-5000 / (800) 558-5236 Fax: (414) 570-5010 / (800) 877-1295 Series TY -FRB — 2.8, 4.2, 5.6, and 8.0 K -factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The Series TY -FRB, 2.8, 4.2, 5.6, and 8.0 K -factor, Upright and Pendent Sprinklers described in this data sheet are quick response - standard cover- age, decorative 3 mm glass bulb type spray sprinklers designed for use in light or ordinary hazard, commercial occupancies such as banks, hotels, shopping malls, etc. The recessed version of the Series TY -FRB Pendent Sprinkler, where ap- plicable, is intended for use in areas with a finished ceiling. It uses either a two-piece Style 10 (1/2 inch NPT) or Style 40 (3/4 inch NPT) Recessed Es- cutcheon with 1/2 inch (12,7 mm) of recessed adjustment or up to 3/4 inch (19,1 mm) of total adjustment from the flush pendent position, or a two-piece Style 20 (1/2 inch NPT) or Style 30 (3/4 inch NPT) Recessed Escutcheon with 1/4 inch (6,4 mm) of recessed adjust- ment or up to 1/2 inch (12,7 mm) of total adjustment from the flush pen- dent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be ob- tained when exposed to corrosive at - IMPORTANT Always refer to Technical Data Sheet TFP700 for the `INSTALLER WARNING' that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 8 mospheres. Although corrosion resis- tant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these coatings for any given corro- sive environment. The effects of ambi- ent temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An intermediate level versions of the Series TY -FRB Pendent Sprinklers are detailed in Technical Data Sheet TFP356, and Sprinkler Guards are de- tailed in Technical Data Sheet TFP780 WARNINGS The Series TY -FRB Sprinklers de- scribed herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association, in addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may impair the performance of these de- vices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Model/Sprinkler Identification Numbers TY1131 - Upright 2.81K, 1/2"NPT TY1231 - Pendent 2.81K, 1/2"NPT TY2131 - Upright 4.21K, 1/2"NPT TY2231 - Pendent 4.21K, 1/2" NPT TY3131 - Upright 5.61K, 1/2"NPT JULY, 2004 TY3231 - Pendent 5.61K, 1/2"NPT TY4131 - Upright 8.OK, 3/4"NPT TY4231 - Pendent 8.OK, 3/4" NPT Technical Data Approvals UL and C -UL Listed. FM, LPCB, and NYC Approved. (Refer to Table A for complete approval information including corrosion resis- tant status.) Maximum Working Pressure 175 psi (12,1 bar) Discharge Coefficient K = 2.8 GPM/psis/2 (40,3 LPM/bars/2) K = 4.2 GPM/psis/2 (60,5 LPM/bars/2) K = 5.6 GPM/psis/2 (80,6 LPM/bars/2) K = 8.0 GPM/psil/2 (115,2 LPM/bars/2) Temperature Ratings Refer to Table A and B TFP171 Page 2 of 8 ESCUTCHEON 7/16" (11,1 mm) PLATE SEATING1/2„ ** NOMINAL SURFACE NPT MAKE -IN 1 1 2-1/4" (57,2 mm) 1-9/16" (39,71 mm) ' 1 SSP DEFLECTOR PENDENT STYLE 10 or 20 RECESSED ESCUTCHEON SSU* DEFLECTOR 2-7/8"(73,0 mm) DIA. 7/16" (11,1 mm) i NOMINAL MAKE -IN NRENCH 2'3/16" FLATS (55,6 mm) 1/2" NPT** RECESSED PENDENT UPRIGHT TFP171 CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression 7 - Bushing orifice seat on frame. Screw **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 1 QUICK RESPONSE SERIES TY -FRB UPRIGHT (TY1131) AND PENDENT (TY1231) SPRINKLERS 2.8 K -FACTOR, 1/2 INCH NPT ESCUTCHEON 7/16" (11,1 mm) PLATE SEATING1/2„ ** NOMINAL SURFACE NPT MAKE -IN 1 2-3/16" (55,6 mm) 1-1/2" (38,1 mm) SSP DEFLECTOR* PENDENT STYLE 10 or 20 RECESSED SSU* ESCUTCHEON DEFLECTOR ~— 2-7/8"(73,0 mm) DIA. I'N 7/16" (11,1 mm) NOMINAL MAKE -IN � � � 2-3/16" NRENCH (55,6 mm) FLATS 1/2" NPT** RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw "Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 2 QUICK RESPONSE SERIES TY -FRB UPRIGHT (TY2131) AND PENDENT (TY2231) SPRINKLERS 4.2 K -FACTOR, 1/2 INCH NPT Finishes Bulb . . . . . . . . . . . . Glass n Sprinkler: Refer to Table A and B Compression Screw . . . . . Bronze operation Recessed Escutcheon: White Coated, Deflector . . . . . . . Copper/Bronze Chrome Plated, or Brass Plated Bushing (K=2.8) . . . . . . . Bronze The glass Bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the Physical Characteristics Frame . . . . . . . . . fluid expands sufficiently to shatter the Bronze glass Bulb, allowing the sprinkler to Button . . . . Brass/Copper Sealing Assembly activate and water to flow. . . . . . Beryllium Nickel w/Teflont Y M E a) m m ar Ln is 0 a 0 t TFP171 ESCUTCHEON 7/16" (11,1 mm) PLATE SEATING1/2„ ** NOMINAL SURFACE NPT MAKE -IN 1 2-3/16" (55,6 mm) � 1-1/2" (38,1 mm) STYLE 10 or 20 RECESSED ESCUTCHEON SSU* DEFLECTOR SSP DEFLECTOR* — 2-7/8" (73,0 mm) DIA. 7/16" (11,1 mm) NOMINAL MAKE -IN �� 2-3/16" NRENCH (55,6 mm) FLATS 1/2" NPT** + PENDENT RECESSED PENDENT UPRIGHT Page 3 of 8 CROSS SECTION 6* 5 4 3 1 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 3 QUICK RESPONSE SERIES TY -FRB UPRIGHT (TY3131) AND PENDENT (TY3231) SPRINKLERS 5.6 K -FACTOR, 1/2 INCH NPT ESCUTCHEON 1/2" (12,7 mm) STYLE 30 or 40 PLATE SEATING ** NOMINAL RECESSED SURFACE 3/4 MAKE -IN ESCUTCHEON SSU NPT � � DEFECTOR 1/2" 5 2-5/16" I (58,7 mm) NOMINAL I � � NOM4 MAKE -IN 1-9/16" 2-1/4" 2 (39,7 mm) WRENCH—ter t + (57,2 mm) FLATS 11 3 SSP DEFLECTOR* — 2-7/8" (73,0 mm) DIA. 3/4" NPT ** PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 4 QUICK RESPONSE SERIES TY -FRB UPRIGHT (TY4131) AND PENDENT (TY4231) SPRINKLERS 8.0 K -FACTOR, 314 INCH NPT Listing is based on the requirements of Design NFPA 13, and FM Approval is based Installation Criteria on the requirements of FM's Loss Pre- vention Data Sheets ). Only the Style The Series TY -FRB Sprinklers must be 10, 20, 30, or 40 Recessed Escutch- installed in accordance with the follow - The Series TY -FRB Pendent and Up- eon, as applicable, is to be used for ing instructions: right Sprinklers are intended for fire recessed pendent installations. protection systems designed in ac- NOTES cordance with the standard installation Do not install any bulb type sprinkler if rules recognized by the applicable the bulb is cracked or there is a loss of Listing or Approval agency (e.g., UL liquid from the bulb. With the sprinkler Page 4 of 8 TFP171 SPRINKLER FINISH (See Note 7) inch NPT sprinkler joint should be ob- tained with a torque of 10 to 20 ft.lbs. K TYPE TEMP. BULB NATURAL CHROME WHITE*** (13,4 to 26,8 Nm). A maximum of 30 LIQUID BRASS PLATED POLYESTER ft. lbs. (40,7 Nm) of torque is to be used to install sprinklers with 314 NPT con - 135°F/57°C Orange nections. Higher levels of torque may PENDENT 155°F/68°C Red distort the sprinkler inlet and cause (TY1231 ) 1, 2, 3, 5 leakage or impairment of the sprinkler. and 175°Fl79°C Yellow UPRIGHT 200°F/93°C Green Do not attempt to make-up for insuffi- (TY1131) cient adjustment in the escutcheon 2.8 286°F/141°C Blue plate by under- or over -tightening the 1/2" sprinkler. Readjust the position of the NPT 135°F/57°C Orange sprinkler fitting to suit. RECESSED PENDENT 155°F/68°C Red ThP- e Series TY -FRB Pendent and U (TY1231)* 1750F/79°C Yellow right Sprinklers must be installed in Fi ure 5 g 200°F/93°C Green 1, 2, 5 accordance with the following instruc- tions. 135°F/57°C Orange Step 1. Pendent sprinklers are to be RECESSED 155°F/68°C Red installed in the pendent position, and PENDENT upright sprinklers are to be installed in (TY1231)** 175°F/79°C Yellow the upright position. Figure 6 200°F/93°C Green Step 2. With pipe thread sealant ap- 135°F/57°C Orange plied to the pipe threads, hand tighten PENDENT155°F/68°C the sprinkler into the sprinkler fitting. (TY2231) Red Step 3. Tighten the sprinkler into the and 175°F/79°C Yellow sprinkler fitting using only the W -Type UPRIGHT 200°F/93°C Green 6 Sprinkler Wrench (Ref. Figure 13). (TY2131) With reference to Figures 1, 2, 3, and 42 286°F/141°C Blue1 2 4, the W -Type 6 Sprinkler Wrench is to 1/2" NPT 135°F/57°C Orange be applied to the sprinkler wrench RECESSEDflats. 155°F/68°C I Red PENDENT (TY2231)* 175°F/79°C I Yellow The Series TY -FRB Recessed Pen - Figure 7 200°F/93°C I Green dent Sprinklers must be installed in accordance with the following instruc- 135°F/57°C I Orange tions. RECESSED 155°F/68°C I Red Step A. After installing the Style 10. PENDENT (TY2231p* 175°F/79°C I Yellow 20, 30, or Mounting Plate, as cable, overr the sprinkler threads and and Figure 8 200°F/93°C I Green with pipe thread sealant applied to the pipe threads, hand tighten the sprin- NOTES: kler into the sprinkler fitting. 1. Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. Step B. Tighten the sprinkler into the 2. Listed by Underwriters Laboratories, Inc. for use in Canada (C -UL) as Quick Response sprinkler fitting using only the in Type Sprinklers. 3. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprin- 7 Recessed Sprinkler Wrench (Ref. klers. Figure 14). With reference to Figure 1, 5. Approved by the City of New York under MEA 354-01-E. 2, 3, and 4, the W -Type 7 Recessed 7. Where Polyester Coated Sprinklers are noted to be UL and C -UL Listed, the sprin- Sprinkler Wrench is to be applied to klers are UL and C -UL Listed as Corrosion Resistant Sprinklers. the sprinkler wrench flats. * Installed with Style 10 (1/2" NPT) or Style 40 (3/4" NPT) 3/4" Total Adjustment Step C. After the ceiling has been in - Recessed Escutcheon, as applicable. " Installed with Style 20 (1/2" NPT) or Style 30 (3/4" NPT) 1/2" Total Adjustment stalled or the finish coat has been ap- Recessed Escutcheon, as applicable. lied, slide On the St p le 10, 20, 30, Or y **' Frame and Deflector only. Listings and approvals apply to color (Special Order). 40 Closure over the Series TY -FRB N/A: Not Available Sprinkler and push the Closure over the Mounting Plate until its flange TABLE A comes in contact with the ceiling. LABORATORY LISTINGS AND APPROVALS 2.8 AND 4.2 K -FACTOR SPRINKLERS held horizontally, a small air bubble A leak tight 112 inch NPT sprinkler joint should be present. The diameter of the should be obtained with a torque of 7 air bubble is approximately 1116 inch to 14 ft. lbs. (9,5 to 19,0 Nm). A maxi - (1,6 mm) for the 135°F/571C to 3132 mum of 21 ft. lbs. (28,5 Nm) of torque inch (2,4 mm) for the 286°F/141 °C may be used to install sprinklers with temperature ratings. 112 NPT connections. A leak tight 314 TFP171 Page 5of8 NOTES: 1. Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories, Inc. for use in Canada (C -UL) as Quick Response Sprinklers. 3. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. 4. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/04) as Quick Response Sprinklers; however, the LPCB does not rate the thermal sensitivity of recessed sprinklers. 5. Approved by the City of New York under MEA 354-01-E. 6. VdS Approved (For details contact Tyco Fire & Building Products, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-53-428-3377). 7. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06) as Quick Response Sprinklers. 8. Where Polyester Coated and Lead Coated Sprinklers are noted to be UL and C -UL Listed, the sprinklers are UL and C -UL Listed as Corrosion Resistant Sprinklers. Where Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a Corrosion Resistant Sprinklers. * Installed with Style 10 (1/2" NPT) or Style 40 (3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. ** Installed with Style 20 (1/2" NPT) or Style 30 (3/4" NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable. *** Frame and Deflector only. Listings and approvals apply to color (Special Order). N/A: Not Available TABLE 8 LABORATORY LISTINGS AND APPROVALS 5.6 AND 8.0 K -FACTOR SPRINKLERS SPRINKLER FINISH (See Note 8) K TYPE TEMP. BULB NATURAL CHROME WHITE*** LEAD LIQUID BRASS PLATED POLYESTER COATED 135°F/57°C Orange PENDENT 155°F/68°C Red (TY3231) 1, 2, 3, 4, 5, 6, 7 1, 2, 3, 5 and 175°F/79°C Yellow UPRIGHT 200°F/93°C Green 5.6 (TY3131) 286°F/141°C Blue 1/2" NPT 135°F/57°C Orange RECESSED 155°F/68°C Red PENDENT 1, 2, 4, 5 N/A (TY3231)* 175°F/79°C Yellow Figure 9 200°F/93°C Green 135°F/57°C Orange RECESSED 155°F/68°C Red PENDENT 1, 2, 3, 4, 5 1, 2, 4, 5 N/A (TY3231)** 175°F/79°C Yellow Figure 10 200°F/93°C Green 135°F/57°C Orange PENDENT 155°F/68°C Red (TY4231) 1, 2, 5 and 175°F/79°C Yellow 1, 2, 3, 4, 5, 6, 7 UPRIGHT 200°F/93°C Green 8.0 (TY4131) 286°F/141°C Blue 3/4" NPT 135°F/57°C Green RECESSED 155°F/68°C Orange PENDENT 1, 2, 4, 5 N/A (TY4231)* 175°F/79°C Red Figure 11 200°F/93°C Yellow 135°F/57°C Orange RECESSED 155°F/68°C Red PENDENT 1, 2, 3, 4, 5 N/A (TY4231)** 175°F/79°C Yellow Figure 12 200°F/93°C Green Page 5of8 NOTES: 1. Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories, Inc. for use in Canada (C -UL) as Quick Response Sprinklers. 3. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. 4. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/04) as Quick Response Sprinklers; however, the LPCB does not rate the thermal sensitivity of recessed sprinklers. 5. Approved by the City of New York under MEA 354-01-E. 6. VdS Approved (For details contact Tyco Fire & Building Products, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-53-428-3377). 7. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06) as Quick Response Sprinklers. 8. Where Polyester Coated and Lead Coated Sprinklers are noted to be UL and C -UL Listed, the sprinklers are UL and C -UL Listed as Corrosion Resistant Sprinklers. Where Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a Corrosion Resistant Sprinklers. * Installed with Style 10 (1/2" NPT) or Style 40 (3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. ** Installed with Style 20 (1/2" NPT) or Style 30 (3/4" NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable. *** Frame and Deflector only. Listings and approvals apply to color (Special Order). N/A: Not Available TABLE 8 LABORATORY LISTINGS AND APPROVALS 5.6 AND 8.0 K -FACTOR SPRINKLERS Page 6 of 8 5/8t1/4" (15,9±6,4 mm) FACE OF SPRINKLER FITTING SURFA E SURFACE CLOSURE 2-7/8" DIA. _ (73,0 mm) 2-1/4" DIA. 157 7 mml 3/4" (19,1 mm) 1/4" (6,4 mm) OOUNTING PLATE SERIES TY -FRB 1/8" (3,2 mm) 1-5/16" (33,3 mm) 13/16" (20,6 mm) FIGURE 5 SERIES TY -FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 2.8 K -FACTOR, 1/2 INCH NPT 2-7/8" DIA. _ 5/8±1/4" (73,0 mm) 3/4" (19,1 mm) (15,9±6,4 mm) 2-1/4" DIA 1/4" (6,4 mm) FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE FITTING (3,2 8MM) A-, MOUNTING SURFACE CLOSURE SERIES 1-1/4"(31,8 mm) TY -FRB 3/4" (19,1 mm) FIGURE 7 SERIES TY -FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 4.2 K -FACTOR, 1/2 INCH NPT Care and Maintenance The Series TY -FRB Sprinklers must be maintained and serviced in accord- ance with the following instructions: NOTES Before closing a fire protection system main control valve for maintenance work on the fire protection system that itcontrols, permission to shut down the affected fire protection system must be obtained from the proper authorities and all personnel who maybe affected by this action must be notified. Absence of an escutcheon, which is _ 1/2t1/8" (12,7t3,2 mm) FACE OF SPRINKLER FITTING f \ MOUNTING SURFACE 2-7/8" DIA. (73,0 mm) 2-1/4" DIA, y IS7 � mml TFP171 1/2" (12,7 mm) 1/4" (6,4 mm) 4OUNTING PLATE 1/8" (3,2 imm) CLOSURE SERIES 1-5/16" (33,3 mm) TY -FRB 1-1/16" (27,0 mm) FIGURE 6 SERIES TY -FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 2.8 K -FACTOR, 112 INCH NPT 1/2±1/8" (12,7±3,2 mm) FACE OF SPRINKLER FITTING MOUNTING SURFACE/ CLOSURE 2-7/8" DIA. (73,0 mm) 2-1/4" DIA. yl (S7 9 mm, 1/2" (12,7 mm) 1/4" (6,4 mm) WING .ATE SERIES 1-1/4" (31,8 mm) TY -FRB 1" (25,4 mm) FIGURE 8 SERIES TY -FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 4.2 K -FACTOR, 1/2 INCH NPT used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated or otherwise altered after leaving the factory. Modi- fied sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). Frequent visual inspections are rec- ommended to be initially performed for corrosion resistant coated sprinklers, after the installation has been com- pleted, to verify the integrity of the cor- rosion resistant coating. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of in- specting from the floor level, a random sampling of close-up visual inspec- tions should be made, so as to better determine the exact sprinkler condi- TFP171 5/811/4" (15,9±6,4 mm) FACE OF SPRINKLE FITTING MOUNTIM SURFACE 2-7/8" DIA. _ (73,0 mm) �- 2-1/4" DIA. -� (57 2 mm) 3/4" (19,1 mm) 1/4" (6,4 mm) MOUNTING PLATE 1/8" (3,2 mm) CLOSURE SEHIEb 1-1/4" (31,8 mm) TY -FRB 3/4" (19,1 mm) FIGURE 9 SERIES TY -FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K -FACTOR, 112 INCH NPT CLOSURE SERIES 1-5/16" (33,3 mm) TY -FRB 13/16" (20,6 mm) FIGURE 11 SERIES TY -FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K -FACTOR, 314 INCH NPT tion and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- facturer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with Page 7 of 8 2-7/8" DIA. _ 1/211/8" (73,0 mm) 1/2" (12,7 mm) (12,7±3,2 mm) 2-1/4" DIA. 1/4" (6,4 mm) FACE OF (57,2 mm) MOUNTING SPRINKLER 71- PLATE FITTING 1/ (3'2 mm) MOUNTING SURFACE CLOSURE SERIES 1-1/4" (31,8 mm) TY -FRB 1" (25,4 mm) FIGURE 10 SERIES TY -FRB RECESSED PENDENT WITH TWO-PIECE 112 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 5.6 K -FACTOR, 1/2 INCH NPT 1/2±1/8" (12,713,2 mm) FACE OF SPRINKLE FITTING \ MOUNTINi SURFACE 2-7/8" DIA _ (73,0 mm) 2-1/4" DIA. (57,2 mm) 1/2" (12,7 mm) 1/4" (6,4 mm) MOUNTING PLATE 1/8'. (3,2 mm) CLOSURE SERIES 1-5/16" (33,3 mm) TY -FRB 1-1/16" (27,0 mm) FIGURE 12 SERIES TY -FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON 8.0 K -FACTOR, 3/4 INCH NPT 2-7/8" DIA _ 5/8±1/4" (73,0 mm) 3/4" (19,1 mm) (15,9±6,4 mm) 2-1/4" DIA. 1/4" (6,4 mm) (57,2 mm) FACE OF MOUNTING SPRINKLER (END "B" USED FOR PLATE FITTING IN TO ENSURE ENGAGEMENT 1/8" FIGURE 13 WRENCHING AREA (3,2 mm) WRENCH MOUNTING SURFACE CLOSURE SERIES 1-5/16" (33,3 mm) TY -FRB 13/16" (20,6 mm) FIGURE 11 SERIES TY -FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K -FACTOR, 314 INCH NPT tion and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- facturer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with Page 7 of 8 2-7/8" DIA. _ 1/211/8" (73,0 mm) 1/2" (12,7 mm) (12,7±3,2 mm) 2-1/4" DIA. 1/4" (6,4 mm) FACE OF (57,2 mm) MOUNTING SPRINKLER 71- PLATE FITTING 1/ (3'2 mm) MOUNTING SURFACE CLOSURE SERIES 1-1/4" (31,8 mm) TY -FRB 1" (25,4 mm) FIGURE 10 SERIES TY -FRB RECESSED PENDENT WITH TWO-PIECE 112 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 5.6 K -FACTOR, 1/2 INCH NPT 1/2±1/8" (12,713,2 mm) FACE OF SPRINKLE FITTING \ MOUNTINi SURFACE 2-7/8" DIA _ (73,0 mm) 2-1/4" DIA. (57,2 mm) 1/2" (12,7 mm) 1/4" (6,4 mm) MOUNTING PLATE 1/8'. (3,2 mm) CLOSURE SERIES 1-5/16" (33,3 mm) TY -FRB 1-1/16" (27,0 mm) FIGURE 12 SERIES TY -FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON 8.0 K -FACTOR, 3/4 INCH NPT FIGURE 14 local requirements and/or national W -TYPE 7 RECESSED codes. SPRINKLER WRENCH WRENCH RECESS / WRENCH RECESS (END "A" USED FOR 1/2" NPT MODELS) WRENCH RECESS (END "B" USED FOR PUSH WRENCH 3/4" NPT MODELS) IN TO ENSURE ENGAGEMENT WITH SPRINKLER FIGURE 13 WRENCHING AREA W -TYPE 6 SPRINKLER WRENCH FIGURE 14 local requirements and/or national W -TYPE 7 RECESSED codes. SPRINKLER WRENCH r Page 8of8 TFP171 Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and work- manship when paid for and properly installed and maintained under normal use and service. This warranty will ex- pire ten (10) years from date of ship- ment by Tyco Fire Products. No war- ranty is given for products or components manufactured by compa- nies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse, improper installation, corro- sion, or which have not been installed, maintained, modified or repaired in ac- cordance with applicable Standards of the National Fire Protection Associa- tion, and/or the standards of any other Authorities Having Jurisdiction. Mate- rials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither as- sumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CON- TRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THE- ORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, RE- GARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LI- ABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY AND FIT- NESS FOR A PARTICULAR PUR- POSE, Ordering Procedure Ow-damt yqun local distributor for avail- abfl$t'y.indicate the full product name. Refer to the Price List for complete listing of Part Numbers. Sprinkler Assemblies with NPT Thread Connections: Specify: (Specify Model/SIN), Quick Response, (specify K -factor), (specify temperature rating), Series TY -FRB (specify Pendent or Upright) Sprinkler with (specify type of finish or coating), P/N (specify from Table C). Recessed Escutcheon: Specify: Style (specify) Recessed Es- cutcheon with (specify finish), P/N (specify). 1/2" (15 mm) Style 10 Chrome Plated ............ P/N 56-701-9-010 White Coated ............. P/N 56-701-4-010 White RAL9010' ........... P/N 56-701-3-010 Brass Plated .............. P/N 56-701-2-010 1/2" (15 mm) Style 20 Chrome Plated ............ P/N 56-705-9-010 White Coated ............. P/N 56-705-4-010 White RAL9010'........... P/N 56-705-3-010 Brass Plated .............. P/N 56-705-2-010 3/4" (20 mm) Style 30 Chrome Plated ............ P/N 56-705-9-011 White Coated ............. P/N 56-705-4-011 White RAL9010"........... P/N 56-705-3-011 Brass Plated .............. P/N 56-705-2-011 3/4" (20 mm) Style 40 Chrome Plated ............ P/N 56-700-9-010 White Coated ............. P/N 56-700-4-010 White RAL9010' ........... P/N 56-700-3-010 Brass Plated .............. P/N 56-700-2-010 " Eastern Hemisphere sales only. Sprinkler Wrench: Specify: W -Type 6 Sprinkler Wrench, P/N 56-000-6-387. Specify: W -Type 7 Sprinkler Wrench, P/N 56-850-4-001. TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 P/N 57 - XXX - X i - XXX I TEMPERATURE I MODEUSIN RATING SPRINKLER 330 2.8K UPRIGHT (1/2"NPT) TY1131 135 135'F/57'C 331 2.81K PENDENT (1/2"NPT) TY1231 1 NATURAL BRASS 155 155'F/68'C 340 4.2K UPRIGHT (1/2"NPT) TY2131 4 WHITE POLYESTER 175 175'F/79'C 341 4.2K PENDENT (1/2"NPT) TY2231 3 WHITE (RAL9010)' 200 200'F/93'C 370 5.6K UPRIGHT (1/2"NPT) TY3131 9 CHROME PLATED 286 286°F/141°C 371 5.6K PENDENT (1/2"NPT) TY3231 7 LEAD COATED 390 8.OK UPRIGHT (3/4"NPT) TY4131 391 8.OK PENDENT (3/4"NPT) TY4231 ' Eastern Hemisphere sales only. TABLE C PART NUMBER SELECTION SERIES TY -FRB PENDENT AND UPRIGHT SPRINKLERS Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and work- manship when paid for and properly installed and maintained under normal use and service. This warranty will ex- pire ten (10) years from date of ship- ment by Tyco Fire Products. No war- ranty is given for products or components manufactured by compa- nies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse, improper installation, corro- sion, or which have not been installed, maintained, modified or repaired in ac- cordance with applicable Standards of the National Fire Protection Associa- tion, and/or the standards of any other Authorities Having Jurisdiction. Mate- rials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither as- sumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CON- TRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THE- ORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, RE- GARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LI- ABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY AND FIT- NESS FOR A PARTICULAR PUR- POSE, Ordering Procedure Ow-damt yqun local distributor for avail- abfl$t'y.indicate the full product name. Refer to the Price List for complete listing of Part Numbers. Sprinkler Assemblies with NPT Thread Connections: Specify: (Specify Model/SIN), Quick Response, (specify K -factor), (specify temperature rating), Series TY -FRB (specify Pendent or Upright) Sprinkler with (specify type of finish or coating), P/N (specify from Table C). Recessed Escutcheon: Specify: Style (specify) Recessed Es- cutcheon with (specify finish), P/N (specify). 1/2" (15 mm) Style 10 Chrome Plated ............ P/N 56-701-9-010 White Coated ............. P/N 56-701-4-010 White RAL9010' ........... P/N 56-701-3-010 Brass Plated .............. P/N 56-701-2-010 1/2" (15 mm) Style 20 Chrome Plated ............ P/N 56-705-9-010 White Coated ............. P/N 56-705-4-010 White RAL9010'........... P/N 56-705-3-010 Brass Plated .............. P/N 56-705-2-010 3/4" (20 mm) Style 30 Chrome Plated ............ P/N 56-705-9-011 White Coated ............. P/N 56-705-4-011 White RAL9010"........... P/N 56-705-3-011 Brass Plated .............. P/N 56-705-2-011 3/4" (20 mm) Style 40 Chrome Plated ............ P/N 56-700-9-010 White Coated ............. P/N 56-700-4-010 White RAL9010' ........... P/N 56-700-3-010 Brass Plated .............. P/N 56-700-2-010 " Eastern Hemisphere sales only. Sprinkler Wrench: Specify: W -Type 6 Sprinkler Wrench, P/N 56-000-6-387. Specify: W -Type 7 Sprinkler Wrench, P/N 56-850-4-001. TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 TECHNICAL Permit # 11656 Address R31 Cox-ok'�ve, Sf Project description al,�,��„C, kosp�'61 CC�ln�rnpiG V�lm.,��cal i,P.t�Aen-� ��Y-rie�'' Wc01 Iq DI Date the permit was finaled 7 Number of technical pages I I C��t,(. (--t l� a.r✓ a ��� �L 4 L. Q � �i � r f oM L -i ,je� u e.g t e� �. t r�� - s�t-w�--dC' ,,..� ,/eti ...�,•� c.o ....G...'� c b eA--l& ems+ .� { _� 1� 't f� o Q i- 07, 40 i� W A„ LAJ t ,N tz) co Oy / 1l.A vi n• ti t IST 6 ON 4 o Ci g' 105 b0 CTble. /b�'c t� CCuPai- cy C4,1 -,e -d /y S a� %GG/r /6.z:,: fid. 2 �i•.o.Ls 5f4fr� �st•i 6'3a 2.•3 x/�v.wc e-Ql W 3 a (D 36) CAL. a b't4` l 2r. 5S u G ACL) �- �S� IMOD p'Sr tA, 2 .y :ai,xfnt...�;bCeGY. r:..¢Sf.S 1 .. •,� f�'' � � ( ..._..» } _—. �-SSv�--a, ,.. ., dui a to 5t'1p t dove/tet 5. G.3 I2 i ;? •t: � E - J D J C LAr-o, I I 4;L " 5 A55�- A - T y -4T;l G. m 7 -DI O� L"IV -p tot-- of - -2.. '.5- W 1. yYo's-xISa -- !3/2 3r +o9y Z6 Z, z s 5 188 ISO S� , L13 S S W� III Zl$ yah 3 - ` s� !vim j S�yti r Z, 31r ,v � o Gso p � ` � z Cwa63� � i'aoa pS�,L tj oo IOS� v1 W3 Y5;W ,1, flb 33 _ I, 93 ' v/ 3 7 -,s - "C' -S 4 = 11,063-,y 914141 3 Y5;W ,1, flb 33 _ I, 93 ' v/ 3 7 -,s - "C' -S `a o � to e.- Oo..rk(o�- K 3� i...X, 3 .}� = 1 7,l 3 { Zs f 3 t v 13ep I , rL 11 �- I $ _ `i %.g 41 urE, S3Y� fZ86G /s-vo Pig 4 = 11,063-,y 914141 t'} 4,. Vol r ` 1.3cac PIS , Bio .. :2 or, t }f� `a o � to e.- Oo..rk(o�- K 3� i...X, 3 .}� = 1 7,l 3 { Zs f 3 t v 13ep I , rL 11 �- I $ _ `i %.g 41 urE, S3Y� fZ86G /s-vo Pig 0 <1 IQ 'A I't A- 0,11 IIN , ov 9"/ 7f- 0 z rw Cn 04 2 I A )4 z )e Iz 0 S"z CI? -U(Z t Y YO, po of srl o0oly 0 4 ol-�ao v ly T C, j v 4T 4-rara 71n -v, c4l o I M& pv()n 104 000 an 4A #A xxx in f" m "I rn m -4-4-4 SA tA 1A %z E-roJG v FHl4A- W t wo /a — gra �t yes co Z _o _v'I y "r'D Z conn cvww t10f Z k j U - !/ 5'/> t t� r�L fly_ _- G► Pd rpt _ o �o 3"t�Cycv/d �r4 ex ` It f �, wi �. •art 0 4 D fi i 3,YAA v��� ,,A ! 6 o,q A S T -//t, 5 T��s is 4 96► P r A-5 2 6,A t4 W."'t AAS DS OA Ln LM (�_) AA LUWW lu LU W xxx V) V) t Ln r 000 In2o 04 it av 2 7-At 7. A C4 C4 C4 C4 C4 IQJ ki /k Aly 41 49, 5 !Z, 7a- 0 6, 0 -4. A"La-Ov� f&l 'Yl '- S , vrl7LO bw 4/ 5 -Y 0', 00Z 0 Z. Ale kyrZ �3 6 14� (,z 0, 7,Y T bukd Li v13 C, '9 7- A ?- c e. Q ? I, tepj. 10 )(Jj PS a t!9W ff 0-1 s 0 -FV-4,T j=qlG-t'-4�4,tl' VJ Si--.C,-T il ft2r_ Iry 0 o Tt� J> 4 , tye.,* -7 1 -Z% '-- T bukd Li v13 C, '9 7- A ?- c e. Q ? I, tepj. 10 )(Jj PS a /,-Jow--j 0sf-,40 tA4 parAv 01111 17X-VY7�' "A ley 1z (TZ tj ?R --z is /-S, I ..Z /S A -A Z,,Z./..y/ ow-, = J Hro 56,31 -tow 1(41�1 000 07 mmm F—IM jv.� m m m -4 - LA 4 _f fA vii 0 9 rn Q X� 1, b Q*0-1 -_zV (.4 a FA f i' �1��-0= 3}3 (G 33 7b 0,Z) 1$3� .lfIL2 j \l/lr Flt:-, 0 1„1- fib- to = - V / b 19 Z/ "L `�' 1 1 � 8 3 • W W W 1. S3 f N N N ao� N0O wci t�0.4,'�C1l.33'� n"Yo = 1Y14'�/ �G L•LG•I ) V e' CAI's`�+, // Y/ G04 S •6Y U�Y 4� P ry ` W N C4 t4 C4 AA JA- :•;�' y�,,_ :4. ,�,�. ,�.��.5. � � �. i x.20' 1. ' 3 fij7 }- 14 3.3) b�'�-.e:,; Ah t / Uti} �.) = � a r i 3� �` �i• 33� � ^�; t.SZf _ I i }L � �l t'E .111�.1.tc•f" � 1~'t[SS-`'yt �'t�rr"t+ ��'re.s$ 2400,0 f i' A K orev '7- "b I zrwP 6,� Wt,,l / AAODL 3= i—; Fy --a rwe., t w,,—Vb It, I,, _ q 10 -- 11, N-- 1% lvcj--: i4i7*At �l A4 =d 3 +14+{.141'0 V� v J 6, 4-t, (. C) .5 ,t -6 3d > Alf 961'r eql'uAy lo -c- Vll Seip J�.r AA -d-` 777 'C"J fp .4 Z-2. -AA 31 14 -5 0 6 4 + 2-0 o lz� T. -:�. 313 ( t 3 -5) + I Ll I 10 LU WW C2 W%G- i" lu Im xxx An 0 0 co00 o cvv &M IC', — C4 A C4 C4 C4 C4 "Oote- +y 4 4-,j �i6 Nor- 31301 3- +'100 + loo A/ v its ,v - Wit Mof f SS'6 10 A)Orf,;,,' -rc,, s'o Dda.-le-le, i6l 7-f 0 -Tiv of '7W6 5-1 /_e r4 kievi 0 3 04-?, 0 04 (0 lk,l ��I- W W W to 1A Yf OOO of O O C4 C4rC4 i109 otf V ),Ve5 W- 313111�t ��.MQ_ o = 3,3(6,33) f 1 L y��) yt� J. t_ h r lb 42,61 C; Co -330" xc m:66��- ,�f- 2`.3fl G e.s6 �� = 6.Q'Z:v o � .3.�•.3��G, :3°3�� t: l Yl �C, a_ y�.��:,�,.- �• :� s �?� � ' '� �J� �� b __ ` .._ ~-- i i r S b -ea Cje� �l2�id� S 0- fg,5-0 o ;;, /Y/,7 c �6- L /,D CA- F he+" - Ileo x. DA7.j. ! _. /s. P. 7 vSe t¢ � 30 ok �_ 32t� 3 j �$SO D�J3 i109 otf V ),Ve5 W- 313111�t ��.MQ_ o = 3,3(6,33) f 1 L y��) yt� J. t_ h r lb 42,61 C; Co -330" xc m:66��- ,�f- 2`.3fl G e.s6 �� = 6.Q'Z:v o � .3.�•.3��G, :3°3�� t: l Yl �C, a_ y�.��:,�,.- �• :� s �?� � ' '� �J� �� b __ ` .._ ~-- i i r S b -ea Cje� �l2�id� S 0- fg,5-0 o ;;, /Y/,7 c �6- L /,D CA- F he+" - Ileo x. DA7.j. ! _. /s. P. 7 vSe t¢ � 30 ok �_ ig os- W&W 5e ol- C 5-0 "." I= .9 /ft 3 /3 65-) — IZO (6 err? -r6 13 S70 WWW xx us A, in 0 vi 000 -04 :!,13 A A A C14 04 C4 a A4 rat rC�c _)LOA, re .,I 'E e, S'll x I ��C4- op - O—eoP all t "-21 6� Al 21 L?o A le- /�Y 7" A4 Aso 69 3 3,� -d-P its, 71 •;;f 4 W,•al w 06 TO" . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . fitly 14 a . w ift ikvf .4" V WIM Z Im Mt " rt M kAX' v P"1141L J, _W "gx. 0S mill; MW IPA F V i I J "tch mi'v ww. MM W -*1 Ni -Al A, �t yh�.011Z.1i, Lou W. 00r 20 � t o! I I. - "oo —4; /1 10), �e . �"4NMOk'I"i "1411 t's NOW, 'N' i I J "tch mi'v ww. MM W -*1 Ni -Al A, �t yh�.011Z.1i, Lou W. 00r 20 � t o! I I. - "oo —4; /1 10), �e A t's NOW, mv 1. 4". A TECHNICAL 117 Permit # Address 3 q ar o vle, Project description aVA, O � 1 CAPAMOIii al POS-Pi�( (�a�h �himnce -Re-�octet 4 L a st Ch~%ra vl ce A -AA,+ o vi C KS 41`6 313 COP -2.o P -p u nivLi vx A A,+oh Date the permit was finaled Number of technical pages 2-o Dear Mr Swanson, We are responding to DOH review and comments dated June 4, 2002 for the addition of a QP freestanding water sculpture feature to the hospital main lobby We have reviewed and provided responses to each of the noted comments. The attached response addresses each comment. Additionally we have attached sketches detailing the associated utilities. The medical centers infection control practitioner had endorsed the design. There are no structural issues as the fountain sits on an existing interior concrete slab on F grade. incerel Ji Paapke, irector, Facility Management encl Comments responses Fountain rendering O PAP Penny Becker PhD,Infection Control n Functional Program Kloppenberg Shop Drawings (6 pages) Architectural sketches ASK -20 1 and ASK — 20.2 (2 pages) Mechanical sketches MSK -20 1, MSK -20.2, and MSK -20.3 (3 pages) Floor sink cut sheet (1 page) Electrical sketches ESK-20 1 and ESK-20.2 (2 pages) Cc Donna Davison, Olympic Memorial Hospital Gary Braun, Mahlum Architects Lou Haehnlen, City of Port Angeles Julie Haguewood, Distinctive Designs Steve Wander, Harmonic Environments OLYMPIC MEDICAL CENTER 939 Caroline Street • Port Angeles, Washington • 98362 3997 • (360) 417 7000 D E� + June 27 2002 Richard M. Swanson, Architect JUL ` 2 2002 J Washington State Department of Health Construction Review & Acute Care Services CITY Of PORT ANGELES 2725 Harrison Avenue, NW, Suite 500 COMMUNITY DEVELOPMENT Olympia, Washington,98504-7852 , Project: Olympic Memorial Hospital Main Entrance Remodel and East Entrance Addition CRS #6313 Subject: COP -20 Fountain Addition Dear Mr Swanson, We are responding to DOH review and comments dated June 4, 2002 for the addition of a QP freestanding water sculpture feature to the hospital main lobby We have reviewed and provided responses to each of the noted comments. The attached response addresses each comment. Additionally we have attached sketches detailing the associated utilities. The medical centers infection control practitioner had endorsed the design. There are no structural issues as the fountain sits on an existing interior concrete slab on F grade. incerel Ji Paapke, irector, Facility Management encl Comments responses Fountain rendering O PAP Penny Becker PhD,Infection Control n Functional Program Kloppenberg Shop Drawings (6 pages) Architectural sketches ASK -20 1 and ASK — 20.2 (2 pages) Mechanical sketches MSK -20 1, MSK -20.2, and MSK -20.3 (3 pages) Floor sink cut sheet (1 page) Electrical sketches ESK-20 1 and ESK-20.2 (2 pages) Cc Donna Davison, Olympic Memorial Hospital Gary Braun, Mahlum Architects Lou Haehnlen, City of Port Angeles Julie Haguewood, Distinctive Designs Steve Wander, Harmonic Environments CRS 6316 Comments Response S24(1) Ozone is an air pollutant and lung irritant. How will you monitor this operation? We will install and atmospheric ozone monitor that will automatically shut off the ozone generator if off -gas levels are too high. If the ozone generator is shut down as a result of;high levels, the entire system will be drained, cleaned and refilled. Since ozone concentrations cannot be monitored in water, how will you assure efficacy and efficiencies? Ozone levels in the water will be monitored by and ORP (Oxidation - Reduction Potential) meter With the ORP type meter can be connected to the main hospital alarm PLC, we will be assured that as long as a .2 to 4 residual is maintained in the water, the waterfall will be micro -biologically clean. Further since disinfecting is the priority, we will employ the use of a backup system that will be integrated with the ORP .Meter above. This backup system will inject small amounts of Hydrogen Peroxide into the waterfall. The same ORP meter measures both ozone and H2O2 levels. S24(2) What organisms will you be looking for in the "water culturing"? We will us a millpore heterotropic plate count sampler A heterotropic count will determine the overall microbiological status of the system. We will be looking for Enteric gram negative rods, Pseudomonas species, yeast and other aerobic bacteria. And at what frequency of testing? Water culturing will occur once a week for a year to establish a correlation to the ORP readings, seasonal variation, and preventative maintenance schedule. We will then adjust the samplmg schedule to obtain relevant data points or sets. S24(3) What problems or infection control do you expect with children playing with the water? With the system described above, the system would be safe. Stainless steel panels, the water returns to the reservoir via a 1 slot in the stainless steel, protect the reservoir S24(4) What parameters were used to establish semi and annual maintenance? The manufacturers recommended maintenance schedule was used to establish the semi and annual maintenance schedule. The schedule will be adjusted, in conjunction and consultation with the Infection Control Practitioner, based on the water culturing and historical experience. With the addition of the hydrogen peroxide, the storage container of H2O2 will be filled monthly The ozone system will require service annually (that's how long the bulb would last on a 2417 operational basis), the RO (Reverse Osmosis) system will require annual service if it were operating continuously S24(5) Please explain how the water is "self -disinfected"? With the addition of the systems above, the system is continuously disinfected and monitored. S24(6) How will you monitor and control moisture and humidity from this display? This display is located in the main lobby of the facility adjacent to the main entrance of the facility In conjunction with water culturing, we will utilize a particle counter Pacific Scientific Instruments Met One Model 227A .5 1 CE NIMH, which in addition to measuring particles, measures temperature and relative humidity This information will be downloaded into a computer program and trended. S24(7) Please provide a copy of this display's plans for plumbing and the "water maintenance system" (RO and Ozone). The partial copy of the plan is incomplete. Please see the attached drawings, Kloppenberg Shop Drawings (6 pages), Architectural sketches ASK -20 1 and ASK — 20.2 (2 pages), Mechanical sketches MSK -20 1, MSK -20.2, and MSK -20.3 (3 pages), Floor sink cut sheet (1 page), Electrical sketches ESK-20 I and ESK-20.2 (2 pages) S24(8) The reduced pressure backflow assembly shall be accessible per Section 603.3.3 UPC. Please refer to the attached drawings noted above All devices will be installed per all applicable codes and regulations. 4w OLYMPIC 1)1(,Al, CF-NTER OLYMPIC MEDICAL CENTER FUNCTIONAL PROGRAM Lobby Fountain May 13, 2002 CRS # 6313 The purpose of this water feature is to provide patients, visitors, staff, and guests with an eye pleasing sculpture that is soothing and relaxing while creating low level background noise to aide in preserving confidentiality of adjacent areas. PROJECT GOALS, PRIORITIES & OBJECTIVES 1 To provide an eye pleasing, soothing, and relaxing water feature/sculpture. 2. A feature/sculpture that creates water noise, low level background noise, that is not offensive, that is soothing and relaxing while improving confidentiality of adjacent areas. 3 Provide a visual impact feature to complement the remodeled lobby 4 Install a "state of the art" system that will provide pure water and is self - disinfecting. MAINTENANCE The following items have been put together jointly by Penny Becker, Infection Control, Jim Paapke, Director of Facilities Management and manufacturers recommendations. Weekly - Check and measure dissolved solids to check water purity Check sump water levels Check and verify operation of the Reverse Osmosis Unit Check and verify operation of the Ozone (Silent Air) Unit* *Note Penodic water culturing of in and out water to establish baseline and/or as needed based on Ozone Unit operation. Semi -Annually - Completely drain, clean and refill fountain Annually- RO Unit Replace carbon and sediment filters Replace RO membrane Silent Air Unit (Ozone) Refurbish/charge Silent Air ozone unit pke, Dir tor, Facility Management PtennyBecker hD, Infection Control N GENERAL NOTES OWNER IS TO PROVIDE THE FOLLOWING 1) MANPOWER AND EQUIPMENT REQUIRED TO UNLOAD THE CRATED PRODUCTS FROM THE CARRIER'S TRUCK DELIVERED TO THE JOB, AND TO ASSIST OUR INSTALLATION SUPERVISOR IN MOVING MATERIALS INTO PLACE PLEASE CAREFULLY INSPECT THE CRATES, NOTING ANY VISIBLE DAMAGE ON THE BILL OF LADING, AND PROVIDE SAFE STORAGE FOR THEM PRIOR TO INSTALLATION. 2) PLUMBING CONNECTIONS A - STANDARD 3/8° WATER LINE TO THE BASIN, CONNECTED TO AS PURIFIED A WATER SOURCE AS POSSIBLE, SUCH AS DISTILLED OR DEIONIZED WATER OR A REVERSE OSMOSIS SYSTEM, TO MINIMIZE CLEANING AND MAINTENANCE B - 1 1/2" NPT S/S COUPLING DRAIN WITH PVC STAND PIPE O'FLOW BY HARMONIC ENVIRONMENTS, FOR CONNECTION TO 1 1/2" DRAIN LINE BY OTHERS 3 ) STANDARD 12" X 12° COMMERCIAL FLOOR SINK, FLOOR DRAIN, OR HARD PIPE TO BLDG WASTE LINE 4) STANDARD 115 VOLT GFI OUTLET(S) 5) LEVEL SURFACE FOR THE BASIN. 6.) STRUCTURAL SUPPORTS AS NECESSARY PROJECT- GL OLYMPIC MEDICAL CENTER SINE SIDED K L O P P E N 13 E R G PORT ANGELES, WA. STAINLESS STEEL 262, WEST OXFORD PREPARED FOR HARMONIC ENVIRONMENTS WATER FEATURE 3o 61. COLORADO 80110w�� is � FORT LAUDERDALE, FL. DATE: W-30-02 DRAWN BY: M.L.S. SCALE: AS NOTED JOB NO. 9884 - SHEET 1 OF 6 GRANITE LIMESTONE SHOWN ISOMETRIC WATER FEATURE 1/2' = 1 -0' KLOPPENBERG "" OLYMPIC MEDICAL CENTER SINGLE SIDED PORT ANGELES, WA. STAINLESS STEEL 2627 WEST OXFORD PREPARED FOR- HARMONIC ENVIRONMENTS WATER FEATLIRE ENGLEWOOD, COIDRAD0 6D116 SOY76H60i QuaUtV a'sm sur swr FORT LAUDERDALE FL. DATE 01-30.02 DRAWN BY: H.L.S. SCALE: AS NOTED JOB N0. 9884— SHEET 2 OF 6 GRANITE LIMESTONE SHOWN 6 L lL PLAN VIEW WATER FEATURE 7/16 = 1 -0' 19� 179h 1 N ------------------------------------ I` 18$ I 21j' —I— 135' I 1774' LEFT SIDE WATER FEATURE 7/16 = 1 -0' KLOPPENBERG 2627 WEST OXFORD ENGLEWOOO*COLORADO SOHO 303-761-1615 Quality is the But Buy FRONT VIEW WATER FEATURE 7/16 = 1 -0' PROJECT- OLYMPIC MEDICAL CENTER PORT ANGELES, WA. PREPARED FOR- HARMONIC ENVIRONMENTS FORT LAUDERDALE, FL. SINGLE SIDED DATE 01-30-W STAINLESS STEEL DRAWN BY: M.L.S. WATER FEATURE SCALE: AS NOTED JOB NO. 9884— SHEET 3 OF 6 DRAWING NOTES LETTER DESCRIPTION (4f 1 SLOT TO ACCOM. PLUG/CORD @ BOTH ENDS OF WATER FEATURE BASIN. 115V WALL OUTLET BY OTHERS. (20 ft.cord) 3A. (T-304) S/S KET SUPPORT LIMESTONE LIDS IDS W rT I LI\ I LI -1 I UI\L 1/2' = 1 -0' GRANITE LIMESTONE NOT SHOWN KLOPPENBERG P"0JEcT OLYMPIC MEDICAL CENTER PORT ANGELES, WA. 1627 WEST OXFORD FFEYARED FOR' HARMONIC ENVIRONMENTS SHS-La1-1615 COLORADO 60116 auat+iv is the Best Buy FORT LAUDERDALE, FL. ISOMETRIC WATER FEATURE 1/2' = I -0' SINGLE SIDED DATE 0I-30-02 STAINLESS STEEL DRAWN BY: M.L.S. WATER FEATURE KALE: AS NOTED JOB NO. 9884— SHEET 4 OF 6 DRAWING NOTES LETTER DESCRIPTION 2A SLOT @ BOTH ENDS OF WATER FEATURE BASIN, TO ACCOM. WATER INLET CONNECTION BY HARMONIC ENVIRONMENTS. 3/8' WATER LINE BY OTHERS. 2B 1 1/2'NPT S/S COUPLING DRAIN WITH PVC STAND PIPE O'FLOW BY HARMONIC ENVIRONMENTS, FOR CONNECTION TO 1 1/2' DRAIN LINE BY OTHERS. _ 36 1 TYP11- PLAN VIEW WATER FEATURE 1/2' = 1 -0' 57' .D m �u 2A r7- e 2B 6 2B 18' 135' LEFT SIDE FRONT VIEW WATER FEATURE WATER FEATURE 1/2' = 1 -0' 1/2' = 1 -0' OLYMPIC MEDICAL CENTER KLOPPENBERG PORT ANGELES, WA. z62TWEST OXFORD PREPARED FOR HARMONIC ENVIRONMENTS 303-6w�' `°L°R"°° °d1D Qwa:iv u N. eue a I, FORT LAUDERDALE, FL. GRANITE LIMESTONE NOT SHOWN I 1 TYP 36 _1 _ _ SINGLE SIDED DATE: 01-30-02 STAINLESS STEEL DRAWN BY: M.L.S. WATER FEATURE SCh: AS NOTED JOB NO. 9884— SHEET 5 OF 6 COMPONENT LIST NO. QTY DESCRIPTION (� 10 C,H.G. #A10-0854 - #16 GA. S/S FLANGED ADJ. FOOT INSERT WITH MOUNTING HOLES, O 2 NAUTILUS 45 FOUNTAIN PUMP (20 ft. cord) O 1 NAUTILUS 60 FOUNTAIN PUMP (20 ft. cord) i 3' _2 D II II ® � 0-o I �OA I N (M) 3/4 POLISHED LIMESTONE. U LEGS 1 5/8'0 X #16 GA. (T-304) S/S TUBING. (K srIFNR #18 GA. <T-304> S/S 2B. (J-HANNEL #18 GA. (T-304) S/S 2B. rI I (H BAFLE #18 GA. (T-304) S/S 2B. (G SINK #16 GA. (T-304) S/S 2B. L F TOWER #16 GA. (T-304) S/S WITH A NO. 4 II BRUSHED SATIN FINISH. FT luf (E) TOWER 3/4 HONED GRANITE, OWNER TO FACE VERIFY LOCATION OF LOGO. 18, _ (D? LID #14 GA. (T-304) S/S 2B. - (C) BASIN #14 GA. (T-304) S/S 213. � (B? LEVEL #11 GA. (T-304) S/S 2B. SECTION i� 1\ (A) REINF'D #11 GA. (T-304) S/S 2B. j LETTER PART FABRICATION NOTES 1 1/2° = 1'-00 11'6MATERIAL LIST PROJECT K L O P P E N B E R G OLYMPIC MEDICAL CAL CENTER SINGLE SIDED DATE 01-30-02 PORT ANGELES, WA. STAINLESS STEEL DRAWN BY: M.L.S. WATER FEATURE SCALE: AS NOTED Zen WEST OXFORD PREPARED FDR- HARMONIC ENVIRONMENTS JOB NO. 30 6"�' COLORADO°°"° �UV v eA. sue &W FORT LAUDERDALE FL. HEFT — SHEET 6 OF e J SAP L ZY ZZ hS ZL ZOOZ/ZZ/S I MEN WOMEN 1 10 O 117 118 I O 01 REM LEG TE U S BY FOU NN M GR. TO A(CESS 150�p � FLOQR SINK, E _ECT R�D� CED PRESSURE I OUTLETS AND RPBP BACiFIOW PREVENTE4 � L_J 15000 FLOOR SINK � t FOUNTAIN BY RECESiED IN CONCRETE OWNER � SLAB. CENTER WITHIN FOUNTAIN CENTE LINE FOUNTAIN _ BASE ENCLOSURE. � ED EQ I NORTH WAITING 1 � 119 O O Partial Main Lobby Plan 2. SCALE 1/4"=1'-0" QL) OLYMPIC MEDICAL -CENTER WW RDA= AM Mff BaItAM AODM PROJECT NUMBER: 200060771 DESCR�T60t�t COP -20 REfHtE1�CE DRAMgQ AM DATE 03/20/02 ASK -20.1 i 09900 PAINT (TYP ) GRP L -5Y LZ SZ IL Z002/52/£0 -09255 GWB W/ -EXISTING 09900 PLANT SKYLIGHT TO REMAIN I I� FOUNTAIN WITH 15000 REDUCED PRESSURE 09950 WALL GRANITE BASE BACKFLOW PREVENTER COVERING ENCLOSURE 8Y WITHIN FOUNTAIN END � � OWNER ENCLOSURE \ i rte . I !l__J 1 1 15000 FLOOR SINK. CENTER WITHIN /06200 FOUNTAIN END ENCLOSURE. WOOD -16000 GA OUTLETS BASE Partial Main Lobbv Elevation 5 SCALE. 1/4"=1'-0" AA A H L U M architects PROJECT NUMBER: 200060771 D SC TK) kES RiP COP -20 RHIRBJCE DRAWNCc A5.1 DATE: 03/20/02 ASK -202 BASEMENT I BELOW r � I I � I "y I' 1 /2"CIN,• DOWN TO FOUNTAIN CONNEC WITH R LM PR BACITL�ffPI EN H ` I , �-TT (E) 4 WASTE IN BASEMENT 'I a I PATCH OF CONCIVE SLAB FOR WASTE & - —VENT INSTALLATION --_ __ -_ LJ/ -CONNECT 2'b TO (E) --Y - - 2'Y7fV PLUMBING b _ CHASE 141 f 1/2"CW DOWN Tb �+ ! I I AUTOMATIC FLOOR E i j k MAIN WITH TRAP PRIMER \• II E 2-1/2- VTR i, —iz II� r, L 0c)Ji WUSN - AA A1V F LO OIC f AR T -I IA A H L U IA srciltect• PLUMBING PLAN 1/4•=1'-0" o PROJECT NL QOM- 200060771 DESCRPTKK COP -20 REI Rma DRAWL: P-1 DATE 3-20-02 MSK -20.1 fX: C v ;g N 0 1/2• 1/2' -5- - - - - I -� CEILING t i (E) 2-VJ i' PROVIDE 1 /2'CW CONCEALE I PROVIDE 2" VENT 1 IN WALL AND BELOW SLAB � 1 1 1 � � 1 I , 1 FIRST FLOOR 1 t (E) ,w I� BASEMENT 3IN WATER NIS IN WALL AND BEHIND WATER PROVIDE 11,L " CW IN I CONCEALED WALL AND FEATURE SKIRT TO TRAP PRIMER do FLOOR DRAIN BEHIND WATER FEATURE , ICONNECTION SKIRT I WATER FEATURE do I AUTOMATIC TRAP GRANITE SKIRT BY I PRIMER FOR OTHERS —\ FLOOR DRAIN I L_ VALVE riI rim t PROVIDE WATER TIGHT SEAL AT FOUNDATION - PENETRATION II D— PVC DRAIN WITH PVC GATE SHUT—OFF VALVE 1/2' REDUCED PRESSURE BACKFLOW PREVENTERS ROUTE DRAIN UNE TP D--1 UPiREs &V4/NO/ FEATURE PIPING DIAGRAM COP -20 WATER FEATLRE MECHANCAL NOTES: 1 THE FOLLOWING NOTES SUPPLEMENT THE CONSTRUCTION DOCUMENTS DATED JULY 18, 2001 2. VERIFY LOCATION OF WASTE AND WATER CONNECTIONS TO WATER FEATURE PRIOR TO FABRICATION AND INSTALLATION OF FLOOR DRAIN. 3. FIELD VERIFY LOCATION OF EXISTING SERVICES PRIOR TO FABRICATION AND INSTALLATION. 4. PROVIDE SAW CUTTING OF FLOOR SLAB FOR INSTALLATION OF WASTE, AND THAT PORTION OF THE VENT AND TRAP PRIMER THAT IS BELOW THE SLAB. PROVIDE BACKFILL AND CONCRETE PATCH TO MATCH ADJACENT MATERIALS. COORDINATE FINISH WITH GENERAL CONTRACTOR. 5. PROVIDE WALL CUTTING AND PATCHING TO PREVENT PIPING FROM EXPOSED IN OCCUPIED AREAS. COORDINATE FINISHES WITH GENERAL CONTRACTOR. 6. FLOOR DRAIN. D-1 PROVIDE CAST IRON 12 INCH SQUARE WITH 8 INCH SUMP. ACID RESISTANT ENAMEL INTERIOR, ALUMINUM DOME STAINER. ? NICKEL BONZE HINGED GRATE, AND TRAP PRIMER WITH % INCH TAP MANUFACTURER: WADE NO. 9143-6-16, OR APPROVED EQUAL JOSAM OR ZURN. 7 TRAP PRIMERS: MECHANICAL. ADJUSTABLE -TYPE AUTOMATIC TRAP SEAL VALVE, PRESSURE DIFFEFOM ACTUATED, N INCH MINIMUM SIZE. MANUFACTURER: E & S VALVE. INC. OR PRECISION PLUMBING PRODUCTS. 8. REDUCED PRESSURE BACKFLOW PREVENTERS: REDUCED PRESSURE TYPE, LINE PRESSURE OPERATED; STATE AND LOCAL APPROVED; LOW-PRESSURE DROP WITH - ACCESSORIES AND FITTINGS REQUIRED FOR TESTING BY WATER PURVEYOR OR AUTHORITY HAVING JURISDICTION; GATE VALVE ON EACH SIDE. SUPPORTED ON STEEL WALL BRACKETS. MANUFACTURER: AMES. ZURN/WILKINS, WATTS, CLA- VAL, FEBCO. OR APPROVED. 9. BALL VALVES 2-1/2- AND SMALLER FOR WATER SOME, BRONZE, 2 PIECE BODY STYLE, FULL PORT. CHROME PLATED SOLID BRASS BALL, TEFLON SEATS, ADJUSTABLE PACKING, LEVER HANDLE. BLOWOUT PROOF STEM, 150 WSP. 600 WOG. MANUFACTURED APOLLO NO. 77, NIBCO NO. T-585-70. WATTS NO. B6080. 10. SOIL. WASTE AND VENT PIPING BELOW GROUND: ALL SOIL. WASTE AND VENT PIPING SHALL CONFORM TO THE REQUIREMENTS OF CISPI STANDARD 301. ASTM A-888 OR ASTM A-74 AND SHALL BE CAST-IRON SOIL PIPE AND FITTINGS. A. MANUFACTURER: AB&I, CHARLOTTE PIPE OR TYLER PIPE. B. HUBLESS PIPE AND FITTING JOINTS BELOW GRADE. JOINTS FOR HUBLESS PIPE AND FITTINGS SHALL CONFORM TO THE REQUIREMENTS OF ANSI/AWWA C-564 AND FACTORY MUTUAL STANDARD 1680 AND SHALL BE TYPE 304 STAINLESS STEEL FULL SHIELDED COUPLINGS HAVING 4 C. D. E. M A H •rcbitccts SEALING CLAMPS FOR PIPE SIZES 1-1/2" THROUGH 4" MANUFACTURED ABACI, CHARLOTTE OR TYLER PIPE. COUPLING AND SHALL FREE JOI NTGASKETS SHALL BE MADE OF ANSI/ANNA C564 NEOPRENE [al INTERLOCK WITH THE HOUSING ASSEMBLY TO MAKE A SL TWO -BAND COUPLINGS ARE NOT ACCEPTABLE. MANUFACTURER: CLAMP -ALL CORPORATION "HIGH TORQUE". ANACO 'HUSKY SERIES 4000" OR APPROVED MISSION. PROJECT NUMBER: 20 M771 DESCRPTIOht COP -20 REFERENCE DRAWIM P-1 DATE: 3-20-02 MSK -203 03/22/2002 11 15 ET TO 2063819561 LHAN0641 RCV'D(03/22/02 11 15; ;2066245613) Floor Sinks - Square 9140 (12k 12-8) 1 Cast iron 12" square floor sink with 8" sump, A.R.E. interior, aluminum dome strainer and nickel bronze, hinged top NOTE: Seepage flange standard. ANSI load Class Light Duty (Under 2,00016s.) Grate Free Area 36.7 Sq. In. (Nickel Bronze) 54.8 Sq. In. (A.R.E.) 141/2 08'Y$ TY -SEAL 2 i 1 J Page 2 of 2 1193/4 NO -HUB M TOTAL P 02 11 J_ Il PIPE SIZE 1�--- "ADD Y2" FOR (64), A.R.E. TOP OP71ONS FUNNELS catI•o. � 5ufxx p suffix oesaVw 0 9142 2 47 Q 6 Trap Primer t/2 -in. tap = 15 Grate = EF4 4" Dia. NB Funnel = 9143 O 9144 3 47 4 47 9/2 = 16 /4 Grate = EF6 E= EG6 6" Dia. N$ Funnel 2-1/2x6" NB Elongated O 26 Clamp Device Funnel OUTLET O 27 Sediment Bucket EG8 3-'/2x8-1/4" NB 0 TY Ty -Seal (Aluminum) Q 64 A.R.E.'Cast Iron To p Elongated Funnel C7 NH No -Hub (3", 4") Q i 79 Security Screws = IC Inside Caulk (3", 4") 3-2-98 Tylsr Pipe/Wade Division • P.O. Box 2027 • Tyler, TX 75710-2027• (903) 882.5511 • FAX (888) 879-9233 Floor A C Sinks 2G J TOTAL P 02 7 ELECTRICAVDATA 121 DIRECTORS OMCE 128 OFRCE _ 134 i00M 2-1 F OFFlCE 135 w CORRIDOR 114 EXISTING PANEL IA6 MEN WOMEN CORRIDOR O O l 117FI-18-1 10 O 115 CORRIDOR 116 00 �, Ij �r1 O 2 32 2 (1) NAUTILUS 60 FOUNTAIN L(2) NAUTILUS 45 PUMP & OZONE PUMP FOUNTAIN PUMPS NORTH WAITING 119 VOLUNTEER DESK 136 FOUNTAIN AREA PLAN SCALE 1/8" = 1'-0" CONSTRUCTION NOTES REMOVE EXISTING SPARE 50A -2P BREAKER AT 1 A6-3234 & REPLACE WITH (2) 20A -1P CIRCUIT BREAKERS. COORDINATE RECEPTACLE LOCATIONS WITH MECHANICAL EQUIPMENT jejopg; 71ON arckitects OLYi'vIPIC PROJECT NUMM 2000607.7VM DISCRPI ole COF-20 MAWM E11 DATE 03/26/02 EW --2111 LOAD SUMMARY - PANEL 1A6 200A, 208Y/120 V., 3 PHASE OLYMPIC MED: CAL CENT E:R kA a PROJECT NUMOM 2000607.71/1D33 DBO PTU t COP -20 R efa DRAWNG ELI DATE 03/26/02 ESK--202 CONNECTED DEMAND DEMAND LOAD DESCRIPTION LOAD -kVA FACTOR kVA AMPS EXISTING LOAD PER RECORD DWGS 62.2 1.00 62.2 173 DELETED LOAD -MAIN LOBBY REMODEL RECEPTACLE LOAD -0.5 1.00 -0.5 -1 LIGHTING LOAD -0.1 1.00 -0.1 0 TOTAL DELETED LOAD -0.6 -0.6 -2 ADDED LOAD -WATER FOUNTAIN CKT 1A6-32: PUMPS 1.2 1.00 1.2 3 CKT 1A6-34 PUMPS 1.0 1.00 1.0 3 TOTAL DELETED LOAD 2.2 2.2 6 TOTAL LOAD - PANEL 1A6 63.8 63.8 177 0 208Y/120V 3PH, 4W OLYMPIC MED: CAL CENT E:R kA a PROJECT NUMOM 2000607.71/1D33 DBO PTU t COP -20 R efa DRAWNG ELI DATE 03/26/02 ESK--202