Loading...
HomeMy WebLinkAbout2125 W 16th St - Building l1li'7 ~7 .. Application Number Application pin number Property Address ASSESSOR PARCEL NUMBER: Application type description Subdivision Name Property Use Property Zoning . . . Application valuation 08-00000923 Date 053713 2125 W 16TH ST 06-30-00-9-2-0100-0000- ELECTRICAL ONLY 8/04/08 RESIDENTIAL TRAILER PARK o Application desc 200 amp service Owner Contractor O'CONNOR, MICHAEL E 5148 MT PLEASANT RD PORT ANGELES WA 98362 (360) 452-5848 STRAITS ELECTRIC PO BOX 2914 PORT ANGELES (360) 452-9104 WA 98362 Permit ELECTRICAL NEW RESIDENTIAL Additional desc Permit pin number 131151 Permit Fee 75.00 plan Check Fee Issue Date 8/04/08 Valuation Expiration Date 1/31/09 N r:-- .00 o }'J ~ Qty 1. 00 Unit Charge Per 75.0000 ECH EL-RM-0-200 1ST SRV FEEDER Extension 75.00 Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 75.00 75.00 .00 .00 Plan Check Total .00 .00 .00 .00 Grand Total 75.00 75.00 .00 .00 s ~ a--. ~ .,. .' . ... ~ SPECTION ELECTRICAL TYPE DATE: RESULTS: INSPECTOR: DITCH SERVICE .~ OUGH - IN FINAL OMMENTS: ~"/30/2008 14:46 FAX 3604574698 IR IE C I&i-VrE9cTR1C 1ilJ01,_ ce-Ot?3 e . , JUl 3 0 20 ' DB ELECTRICAL WORKPERMIT APPLICATION UGHT DEPT. Job wired by ~ Electrital COlltratlor 0 OWDer IosraUation desaiption o Commerei.aJ ){Re5IideDtial o New )(A.1tendJAdditiOD ~'o"l!leclnc &RAi!i.OI(rEat<Ext;I~ prtr~ ~Z't!1 'f flnlt& SIA AI ftred seN!CL @ \ S J'. \]' IP %3b~ FAX number Lf~-%qo I lJnnOY' 1ti ~..pe"lliJ llo ;J;eR.: ~f ~/-cg, PhOne Dumbrl'" to Ir rdulr ialprrtian: L1Q ~/(J7/ Owne'r as defined by RCW.J9.28.26J:(J) Owner will occupy lI,e structlJ1'f! fo, two yean after thU electrical permit u finalized.. (2) Owner is required In lUre an electrical COntractur if "bove said prapL'r1y ~ for sale, ,-err' or lease. After readinG" the above statement, I hcn:by certify mar I am the owner of the abovc named prOperty Or a licensed electrical contractor. I nm milking the electrical tnsml- lation or alteration in compliance with the electrical1'3ws, N.E.C., RCW. Chtlplet" 19.28y W . Chilptcr 296-46B. The CilY of Port Angeles Municipa.l Code, and UtiI' ". cations. r OWDer. electrical conlractor or eleClrlcal adm.ia,l51rator Date: '1-21--08' o Cash Cl Check # o Credit Card VISa Card # Mastercard Discover Expirati01l Dale of card E I IL A iti n " r [J NO LOAD CHANGES [J Baseboard KW C Furnace _ KW [J Heat Pump Ton LAR [J Fan-Wall KW t in Service Informallon a Overhead Service [J Tamp Sel'Yice o Underground Service Voltage Pha.. [J 1 [J 3 Service Size: _ Feeder Slze: SAME DAY INSPECTION. CALL BEFORE 7:00 AM 360-417-4735 DIIO ~vecl.D)' SERVICE fj/W'/ct ~ . Dlt~ Appnr><~By FEEDER Dal~ ~"cdB:r/ ~GfJ.JN & D." ~!'! FINAL ~~ THERMOSTAT "'.. Af:rpnlwed By DITCH lall'peClion Date Area, Building or Equipment Inspected Action Taken Eleetrical In~pector 115- ColVNeGT TO Se~ IGe, 2.30,'UI' fi , I ~. ELECTRICAL INSPECTION WIRING REPORT 417-4735 PERMIT # Og -C/12 '3 INSPECTOR OWNER/CONTRACTOR ADDRESS b APPROVED NOT APPROVED o .................... DITCH. . . . . . . . . . . . . . . . . . . . 0 D.. . . . . . . . .. . . . .. ROUGH IN/COVER... . . . . . . . .. . . . 0 D. . . . . . . . . . . . ... . . .. . SERVICE. . . .. . . . " . . .. . . . . . 0 D.................... . FINAL ....................~ CORRECTIONS NEEDED: 'R"l'f.MO\7"E- fl L.L- 4;flI1Ivn~N"1 1,)") \I~~ ~J ~..c;J.e.1 LAz._ (' 0 1<1. .Tl~.17 0 \:> ~ NOTIFY INSPECTOR WHEN CORRECTIONS ARE COMPLETED WITHIN 15 DAYS - DO NOT REMOVE - OLYMPIC PRINTERS, INC. (360) 452-1381 ELECTRICAL INSPECTION WIRING REPORT 417-4735 DATE 3 g z,e, PERMIT # O@ -0'72...3 OWNER/CONTRACTOR C::T"J <:...( APPROVED NOT APPROVED o .................... DITCH. . . . . . . . . . . . . . . . . . . . 0 o. . . . ... . . . .. . . . . ROUGH IN/COVER. .. . . . . . . . . .. . . 0 O. . . . . . . . . . . . . . . . . . . . SERVICE. . . . . . . . . . . . . . . . . . ~ o. . . . .' . . . . .. . . . .. . . . . FINAL. .. . . ... . . . .. . . . . . . . 0 CORRECTIONS NEEDED: g\(..IDLy' , W t>.-c... .s()-VYDR..~\ 1Y1 ITSl S 291-, - '-/(;& - z.-zn " -. M A.\ v-flA; \ N r, I'f" ....jZ._~NC".F Frzr, h- :::-'E..IZ. UICF"" ~1'J.l/1'''-"TC"E..'''' A)-In Cv.,;..-rr..M.E-f:. =oJ~L<:....\i'J~c.... N~C ( I" c..ul'-t... ct'\L.."-) ON1...'< :S~f2.Vlc...F:. MA;,-, r.oN.PiJC.:TD~ "1>0 ~ ~-rr.p.C~E.j;:> To NlU- 230~ 23 !-1t>,b'l NOTIFY INSPECTOR WHEN CORRECTIONS ARE COMPLETED WITHIN 15 DAYS - DO NOT REMOVE - OLYMPIC PAINTERS, INC. (360) 452-1381 . ~. '!i~r \' , , , \ 7rf(; 1 "" "" 1511 "" "" " " \ ... \ ",,' "' " " J f::) } K , '. ,.'/~ '. ,. ."\ ,. , # , / ;' ( I f'..... t , " '. , I I , ARTICLE 230 - SERVICES .230.31 maintained for a distance of not less than 900 mm (3 ft) in all directions from the edge of the roof. Exception No. ]: The area above a roof swface subject to pedestrian or vehicular traffic .'I_hall have a vertical clear- ance from the roof surface in accordance with the clear- ance requirements of 230.24(8). Exception No.2: Where the voltage between conductors does not exceed 300 and the roof has a slope of 100 mm in 300 rnm (4 in. in 12 in.) or greater, a reduction in clearance to 900 mm (3 ft) shall be permitted. Exception No.3: Where the voltage beryveen conductors does not exceed 300, a reduction in clearance above only the overhanging portion of the roof to not less than 450 mm (18 in.) shall be permitted if (1) not more than 1.8 m (6 ft) of service-drop conductors, 1.2 m (4 ft) horizontally. pass above the roof overhang, and (2) they are terminated at a through-the-roof raceway or approved support. FPN: See 230.28 for mast supports. Exception No.4: The requirement for maintaining the ver- tical clearance 900.mm (3ft)from the edge of the roofshall not apply to the final conductor span where the service drop is attached to the side of a building. (B) Vertical Clearance !'2t~~rJ:@I2f!!'illifondiicto!]. Service-drop conductors, where not in excess of 600 volts, nominal, shall have the following minimum clearance from final grade: (1) 3.0 m (10 ft) - at the electrical service entrance to buildings. also at the lowest point of the drip loop of the building electrical entrance, and above areas or sidewalks accessible only to pedestrians, measured from final grade or other accessible surface only for service-drop cables supported on and cabled together with a grounded bare messenger where the voltage does not exceed 150 volts to ground (2) 3.7 m (12 ft) - over residential property and drive- ways, and those commercial areas not subject to truck traffic where the voltage does not exceed 300 volts to ground (3) 4.5 m (15 ft) - for those (12-ft) classification where volts to ground (4) 5.5 m (18 ft) - over public streets. alleys, roads, park- ing areas subject to truck traffic, driveways on other than residential property, and other land such as culti- vated, grazing, forest, and orchard areas listed the voltage in the 3.7-m exceeds 300 (C) Clearance from Building Openings. See 230.9. (D) Clearance from Swimming Pools. See 680.8. 230.26 Point of Attachment. The point of attachment of the service-drop conductors to a building or other structure 2008 Edition NATIONAL ELECTRICAL CODE shall provide the minimum clearances as specified in 230.9 and 230.24. In no case shall this point of attachment be less than 3.0 m (10 ft) above finished grade. 230.27 Means of Attachment. Multiconductor cables used for service drops shall be attached to buildings or other structures by fittings identified for use with service conduc- tors. Open conductors shall be attached to fittings identified for use with service conductors or to noncombustible, non- absorbent insulators securely attached to the building or other structure. 230.28 Service Masts as Supports. Where a service mast is used for the support of service~drop conductors, it shall be of adequate strength or be supported by braces or guys to withstand safely the strain imposed by the service drop. Where raceway-type service masts are used, all raceway fittings shall be identified for use with service masts. Only power service-drop conductors shall be permitted to be at- tached to a service mast. 230.29 Supports over Buildings. Service-drop conductors passing over a roof shall be securely supported by substan- tial structures. Where practicable, such supports shall be independent of the building. III. Underground Service-Lateral Conductors 230.30 Insulation, Service-lateral conductors shall be in- sulated for the applied voltage. Exception: A grounded conductor shall be permitt~d to be uninsulated as follows: (1) Bare copper used in a raceway. (2) Bare copper for direct burial where bare copper is judged to be suitable for the soil conditions. (3j Bare copper for direct burial without regard to soil conditions where part of a cable assembly identifiecffor underground use. (4) Aluminum or copper-clad aluminum without individual insulation or covering where part of a cable assembly identified for underground use in a raceway or for di-' rect burial. 230.31 Size and Rating. (A) General, Service-lateral conductors shall have suffi- cient ampacity to carry the cunent for the load as calculated in accordance with Article 220 and shall have adequate mechanical strength. (B) Minimum Size. The conductors shall not be smaller than 8 AWG copper or 6 AWG aluminum or copper-clad aluminum. 70-75 : (818/2008) Trent Pepp~808081332.jpg ~==--= .---"\lI' ~ r: ,,~,'q f' . 1-. f; 2..' ...--- - rrzo PI 5 J!Z..tZ.lJ lc.'E- .~ '"" - . , (Zl fl-S o 0 ~ 3 ~ , , , , ~~ , ". .'....,age 1 .__~ J ~" 'D~\?, ". =-, 230.28 Service Masts as Supports. Where a service mast is used for the support of service-drop conductors, it shall be of adequate strength or be supported by braces or guys to withstand safely the strain imposed by the service drop. Where raceway-type service masts are used, all raceway fittings shall be identified for use with service masts. Only power service-drop conductors shall be permitted to be attached to a service mast. Notes to drawings E-101, E-102, and E- 103 (1) An approved roof flashing must be installed on each mast where it passes through a roof. Plastic, nonhardening mastic must be placed between lead-type flashings and the conduit. Neoprene type flashings will also be permitted to be used. (2) Masts must be braced, secured, and supported in such a manner that no pressure from the attached conductors will be exerted on a roof flashing, meter base, or other enclosures. (3) Utilization of couplings for a mast are permitted only below the point the mast is braced, secured, or supported. (4) Except as otherwise required by the serving utility, service mast support guys must be installed if the service drop attaches to the mast more than twenty-four inches above the roof line or if the service drop is greater than one hundred feet in length from the pole or support. Masts for support of other than service drops must comply with this requirement as well. (5) Intermediate support masts must be installed in an approved manner with methods identical or equal to those required for service masts. (6) For altered services, where it is impractical to install U bolt mast supports due to interior walls remaining closed, it will be permissible to use other alternate mast support methods such as heavy gauge, galvanized, electrical channel material that is secured to two or more wooden studs with five.sixteenths inch diameter or larger galvanized lag bolts. (7) Conductors must extend at least eighteen inches from all mastheads to permit connection to the connecting overhead wiring. Guying - Cablo Typo :\'0 tJ. {'Ilf!IVTlHhl.. J/. W~llh~'rh<::ld :llr~l,lfl (',Ibk lt~~ OA""''''--:; ~' .~ I ,,'" \1m ~~_ .. ~~r\l<:<: Ih:tI.~"I r-:". -~ . rl.l~hllll:'''''-,; , . ~ . -....;.... r 1..: I..' I It> I 1111 ~ , .1_____- , '--- .',. ",.I'It..11 ~ ~ sln.Jctural--;-E:.3'.... ~ J\.----I- Fr"llIi~IArrd I .~ Finish Malecmls 'I : ,. Min r'!u,-U.Blllls Mln 2)A Baclo.ing j '\I.lal'hn\".I\1'-'~ !"t,'llu..,I!1 .... ~~-.::::':~:~'~.~: I ~~hl .. "',r Lull:II,,-.("JI;lLII.Link F~Il":C' CI.Ulll' Or F'lIl:L1, ~'1II. . ," Ii.,lt " ", /,11 Tuell)", "~ .. -4-~~-~-:...U 11I<d.lllg 1i,,"1....(.~1\ \1a."[,\1I<1 HlIildinl,!. SIll'EI~..:' I~NlI1I2 G;ll'i.aniled Thil1lb~ And Cable Clamp J'llgtd ~r.:d Cilfll!lIlt Ila"hlllc:OI \1a,Iil' - './' ''"'', ",.?' ~,- , - " G<J~";Jr1il"ud 8dl. Eye-BOI: Op(iDnill .~ . Guying - Stiff-Log Typo \\"'.lll~llh.';I.1 ~.1" ~ , ' . :f' . \h:IfJ!,N'l-[.(udi\I' UClld,sc>:IJ<..'il:1 Min. ' t Ih!;ld ~ll'd C<1!Jo;llIil Or E<ill~1 Elld< rblll'Ilo.....J Am! llnlkd . --"~ J-" S"~":;" ""''''''J C . 'IrJf:~ And Finish Materials ' ;, : , Min ~1 r~' U.Bolts Mill 1..4 BacO;ing I I '<{I 1,',",", I:{tYlll Skd ,. .. COfldllil ,~~~ 1k-llIill : : :: :: :: : ~ : : :: ~ :: : : :: ::: :: : : : l"'~;".- --.: : . GO)'WIffi:5 Spread ::0"- <.. , 60. To~: A!-'?~t. :; ._. . ~1'1I1J " I ------t i\la"t(hcl 1() III~h','r~Il,'Hrad,\'tO'l"'~~ Scn-icc Mast Installation ()ctails ~ .\1",\\, R",lrSllrl:J(>: Drawing E-I 02 http://apps,leg,wa,gov/documents/laws/wac/W A C%20296%20%20TITLE/W A C%20296%", Page 1 of 1 8/8/2008