Loading...
HomeMy WebLinkAbout5.436 Original Contract 5 r 13Lfl Polaris Engineering and Surveying, Inc. 206 South Lincoln Street, Suite 201 Port Angeles, Washington 98362 (360) 452-5393 FAX: (360) 457-9319 PROFESSIONAL SERVICES AGREEMENT FOR THE CITY OF PORT ANGELES Date: May 5, 1997 Client: Mr. Ron Johnson, Field Engineering Specialist City of Port Angeles Department of Public Works P.O. Box 1150 Port Angeles, WA 98362 Project: Port Angeles Library Project East Lauridsen Blvd. at Peabody Street, Port Angeles Submitted by: Polaris Engineering and Surveying, Inc. 206 South Lincoln Street, Suite 201 Port Angeles, WA 98362 (360) 452-5393 FAX (360) 457-9319 Scope of Services: Polaris Engineering and Surveying, Inc. will provide professional services. in conjunction with the site preparation and building construction for the Port Angeles Public Library, to be constructed at the southwest corner of East Lauridsen Boulevard and Peabody Street in Port Angeles. Services will include the follpwing: Observation of the placement of structural fill and compaction testing of structural fill material as set forth in the Contract Documents for the project . Compaction testing of subbase, base, and top rock material for the project Page 2 Professional Services Agreement for the City of Port Angeles May 5, 1997 Observation of concrete placement and testing of the concrete as set forth in the Contract Documents Observation of asphalt concrete placement and compaction testing as set forth in the Contract Documents Coordination of testing of structural steel if requested Polaris will retain PSI (formerly Pacific Testing Laboratories) to provide laboratory analysis of materials as required and for structural steel inspection. Professional Fees: Polaris will charge on a Time and Materials basis for services rendered and costs incurred according to the attached List of Charges for Professional Services. Billings will be on a monthly basis. Payment is due upon receipt of the bill and is considered delinquent 30 days from the billing date. Polaris assesses a 1 % per month service charge on delinquent accounts. Polaris reserves the right to suspend work on projects for which payment is delinquent. Polaris offers a 2% discount for payments received within 10 days of the billing date. Time: Polaris will provide on-site inspections within 24 hours of requests to do so by the Contractor. Authorization: Polaris Engineering and Surveying, Inc. is authorized to proceed with the work on this project subject to the terms and conditions set forth herein. The Client agrees to pay reas a a' r 's fees for collection of delinquent payments for the work complete und r is eement. Date: ro13}0) 7 ~O\ '"'\0 c-,<LEE:{) $\0000 \.OrT\-\o\)\ , Av,\'\oe..\~\o"l. Authorized by: · Polaris Engineering and Surveying, Inc. 206 South Uncoln Street, Suite 201 Port Angeles, Washington 98362 (360) 452-5393 FAX: (360) 457-9319 LIST OF CHARGES FOR PROFESSIONAL SERVICES Prices effective through June 30, 1997 I) PROFESSIONAL SERVICES A) Classification - Office Services Principal Senior Land Surveyor Senior Design Engineer Design Engineer Engineering Technician II Engineering Technician I Survey Technician III Survey Technician II Survey Technician I $90/hr $65/hr $65/hr $60/hr $40/hr $30/hr $50/hr $40/hr $30/hr B) Classification - Field Services Three-Man Survey Crew Two-Man Survey Crew Wetlands Investigation Concrete Testing (Includes equipment) Compaction Testing (includes equipment) Construction Inspection $120/hr $ 85/hr $ 50/hr $ 50/hr $ 50/hr $ 40/hr II) _ OTHER CHARGES Prints 18" x 24" Blueline 24" x 36" Blueline 36" x 48" Blueline 18" x 24" Sepia or Diazo Mylar 24" x 36" Sepia or Diazo Mylar $ 2.00 $ 3.00 $ 4.00 $ 8.00 $10.00 Copies: $ 0.10 Watercraft (20' power boat) $200/day (min. charge $100) Outside Professional Consultants and Services Le., Backhoe and Operator, Permitting Fees (when paid by Polaris) Cost + 5% - ,. PSI (formerly Pacific Testing Laboratories) Engineers. Consultants. Scientists May 8, 1997 Proposal No.: GSC841.1P CLIENT: PROJECT: Mr. Steve Zenovic POLARIS ENGINEERING 206 South Lincoln Street, Suite 201 Port Angeles, W A 98362 Port Angeles Library Project (Job No. 97073) CONTRACT FOR GENERAL SERVICES Peninsula Division 5734 N.E. Minder Road, Suite A-1 Poulsbo, WA 98370-8814 U.S.A Tel: (360) 297-8821 Fax: (360) 297-8828 TEL: (360) 452-5393 FAX: (360) 457-9319 Hour Each Each Each Each Each Each Each Each Each Each Day Mile Field Technician (4 hour minimum to drill asphalt cores) Moisture-Density Determination (Proctor ASTM D-1557) Sieve Analysis (ASTM C-136) Soil Class (does not include Hydro or Atterburg) Marshall Stability & Flow Percent Air Voids Extraction & Gradation Theoretical Max. Specific Gravity (Rice) Bulk Specific Gravity (or drilled cores) Permeability Compressive Strength Samples Compressive Sample Pickup Associated Mileage $ 55.00 $145.00 $ 85.00 $100.00 $200.00 $100.00 $115.00 $ 95.00 $ 48.00 $200.00 $ 15.00 $ 25.00 $ AO Signature of acceptance by an authorized person of the client will render this Contract for General Services and its Terms and Conditions an agreement between Pacific Testing Laboratories and the client. A retainer, if any, will be applied. All hourly rates for field work are portal to portal unless otherwise noted. Penn Seely, Proiect Mana2'er, Peninsula Division~ Pacific Testing Laboratories' Employee Name and Title POLARIS GINEERING Company Name Mav 8. 1997 Date HIGH STRENGTH BOLTS: ALL STEEL TO STEEL CONNECTIONS SHALL UTILIZE 7/8" DIAMETER ASTM A325 N- TYPE BOLTS. TENSION HIGH STRENGTH BOLTS BY DIRECT TENSION INDICATOR METHOD USING LOAD INDICATOR WASHERS INSTALLED PER MANUFACTURER'S INSTRUCTIONS .i)J I' . . PAINT: APPLY ONE SHOP COAT OF RUST -INHIBITING PAINT TO ALL STEEL EXCEPT AT CONTACT SURFACES FOR BOLTING OR WELDING. TOUCH UP SCRATCHES OR UNCOATED SURFACES AFTER ERECTION. >'--.. -, OPEN WEB STEEL JOISTS' PER STEE'L JOIST INSTITUTE SPECIFICATIONS. -j CORRUGATED GALVANIZED STEEL DECKING: ROOF. 3" DEEP, 20 GAGE +S==O.508 IN3 1=0.837 IN4 3" DEEP, 22 GAGE +S==O 394 IN 1=0.655 IN 1~" DEEP, 18 GAGE +S==O.322 IN 1=0.302 IN 1~" DEEP, 20 GAGE +S==O.235 IN 1=0.216 IN COMPOSITE FLOOR: 1~" DEEP, 20 GAGE +S=O.235 IN 1=0.216 IN ( LIGHT STEEL FRAMING: CONFORM TO ICBO RESEARCH REPORTS NO 1713 P AND NO 2392 P FOR STEEL STUD BEARING AND NON-BEARING WALLS. ATTACH COMPONENTS WITH APPROVED SCREW FASTENERS PER MANUFACTURER'S RECOM MEN DA TIONS. INSPECTION: SPECIAL INSPECTIONS ARE REQUIRED FOR: CONCRETE REINFORCEMENT; CONCRETE PLACEMENT; ANCHOR BOLT PLACEMENT: WELDING & HIGH STRENGTH BOL TING - u D U L . \ I GENERAL: THESE DRAWINGS AND NOTES ARE INTENDED TO BE USED IN CONJUNCTION WITH THE ARCHITECTURAL DRAWINGS. ALL DIMENSIONS SHALL BE COORDINATED WITH THE ARCHITECTURAL CONTROL DIMENSIONS. IF INSTRUCTIONS AND/OR DETAILS APPEAR UNCLEAR OR INCOMPLETE, ASK THE ARCHITECT/ENGINEER FOR CLARIFICATION BEFORE CONTINUING. WHERE CONDITIONS OCCUR IN THE PROJECT WITHOUT SPECIFIC DETAILS NOTEP, FOLLOW THE SIMILAR DETAILS OF THE PROJECT. IN ALL CASES FOLLOW THE INTENT OF THE DRAWINGS AND GOOD CONSTRUCTION PRACTICES. HE] AR LI... 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 . SECI'ION 03300 . CAST.IN.PLACE CONCRETE GENERAL Refer to section 03355 for stained concrete finish Submittal!!: Submit the following: Product data for reinforcement, forming accessories, admixtures, patching compounds, waterstops, joint systems, curing compounds, and others as requested by Architect Shqp drawin~ for fabricating, bending, and placing concrete reinforcement. l.ahnrauuy test reports or evaluation reports for concrete materials and concrete mix designs. Written report to Architect for each proposed concrete mix at least 15 days prior to start of concreting. Do not begin concrete production until mixes have been reviewed by Architect Duality Assurance: Comp-Iy with provisions of ACI 301, "Specifications for Structural Concrete for Buildings," ACI 318, "Building Code Requirements for Reinforced Concrete," and CRSI "Manual of Standard Practice," except where more stringent requirements are indicated. ~=~e=~~ce: Owner will engage a testing agency to perform materials evaluation, PRODUCTS Embedded Items: Aluminum items are not to be embedded in concrete. Form Materials: Furnish form materials with sufficient stability to withstand pressure of placed concrete without bow or deflection. Forms for Exposed Concrete Surfaces: Suitable panel-type material to provide continuous, straight, smooth, exposed surfaces. Reinforcini' Materials; As follows: Deformed Reinforciruz Bars: ~STM A 615, Grade 60, unless otherwise indicated. Welded Wll"e Fabric: ASTM A 185. Concrete Materials: As follows: Portland Cement: ASTM C 150, Type 1. Fly Ash: ASTM C 618, Type F. Ai'i'rei'ates: ASTM C 33, except local aggregates of proven durability wa}' be used when acceptable to Architect. ~ Potable. Admixtures: Provide admixtures that contain not more than 0.1 percent chloride ions. CAST-IN-PLACE CONL1ili"I~ 03300 - 1