HomeMy WebLinkAbout535 E 1st St Technical - Building '. ._ ..... _.. ___. uu__. .. . TECHNICAL , 1\ (Jl/ ~~\ . \ ~ \2... \eJr t'\ ~ S\'\\ Sjs\vrf' ." \. Reliable! A Concealed Residential Sprinkler engineered for a minimum design density of 0.05 gpm/ft2 with low GPM requirements. Features 1. Very low water flow requirements. 2. %" (13mm) Total adjustment. 3. Thread-Onffhread-Off cover attachment option. 4. Smooth aesthetic ceiling profile. 5. Available in brass, chrome and black plated or painted finishes. Listings & Approval 1. Listed by Underwriters Laboratories, and certified by UL for Canada (cULus) 2. NYC MEA 258-93-E UL Listing Categories Residential Automatic Sprinklers UL Guide Number VKKW Product Description Model RFC43 Concealed Residential Sprinklers are fast response residential fusible solder link automatic sprinklers. Residential sprinklers differ from standard sprinklers primarily in their response time and water distribution patterns. Model RFC43 sprinklers discharge water in a hemispherical pattern below the sprinkler deflector. Residential distribution patterns are higher and generally contain a finer droplet size than standard sprinkler patterns. The combination of speed of operation and high discharge pattern required for residential sprinklers has demonstrated, in fire testing, an ability for controlling residential fires, and thereby providing significant evacuation time for occupants. The RFC43 Sprinkler provides the best form of fire protection by combining an attractive appearance and W' (13mm) of cover adjustment for ease of installation. The small diameter cover plate is easily and positively attached and blends into the ceiling, concealing the most dependable fire protection available, an automatic sprinkler system. Bulletin 006 Rev.B CD ~ ~ :J o o 0) :0 co :< CD Model RFC43 Concealed Residential Sprinkler (SIN RA0612) The RFC43 is a UL Listed Residential Sprinkler to be installed in the residential portions of any occupancy in accordance with NFPA 13, 13R, & 130. The RFC43 can reduce the need for precise cutting of drop nipples. The threaded cover plate assembly can be adjusted without tools to fit accurately against the ceiling. The fire protection system need not be shut down to adjust or remove the cover plate assembly. Application and Installation The RFC43, for residential installations, uses a 1650F (740C) fusible solder link in a tuning fork style sprinkler frame with a drop-down deflector. This assembly is recessed into the ceiling and concealed by a flat cover plate. The cover plate is attached to the skirt, using 1350F (570C) ordinary temperature classification solder. When the ceiling temperature rises, the solder holding the cover plate releases the cover allowing the deflector to drop into position and exposing the sprinkler The Reliable Automatic Sprinkler Co., Inc., 525 North MacOuesten Parkway, Mount Vernon, New York 10552 " . , inside to ceiling temperature. The subsequent operation of the solder link opens the waterway and causes the deflector to drop into position to distribute the discharging water in a hemispherical pattern below the sprinkler deflector. Any adjustment of thread engagement between the cover plate and cup will assure that the drop-down deflector is properly located below the ceiling. The residential distribution pattern contains a finer droplet size than a standard sprinkler, and the pattern produces significantly higher wall wetting. After a 2 5/8 inch diameter hole is cut in the ceiling, the sprinkler is to be installed with the Model FC Wrench. When installing a sprinkler, the wrench is first positioned into the sprinkler/cup assembly and around the hexagonal body of the sprinkler frame. The Wrench must bottom out against the cup in order to ensure proper, safe installation. The sprinkler Temperature Rating Sprinkler Cover Plate Max. Ambient Temp. 1650F/7 40e 135OF/5re 100oF/38oe Installation Data is then tightened into the pipe fitting. When inserting or removing the wrench from the sprinkler/cup assembly, care should be taken to prevent damage to the sprinkler. DO NOT WRENCH ON ANY OTHER PART OF THE SPRINKLER/CUP ASSEMBLY. MODEL RFC43 CONCEALED SPRINKLERS MUST BE INSTALLED ONLY WITH 1350F RATED COVERS. Cover assemblies provide up to 12" (13mm) of adjustment. Turn the cover clockwise until the flange is in contact with the ceiling. Cover removal requires turning in I the counter-clockwise direction. In ceilings that have a plenum space above the sprinkler, the plenum space may have neutral or negative pressurization but must not be positively pressurized. Inspect all sprinklers after installation to ensure that the gap between the cover plate and ceiling and the 4 slots in the cup are all open and free from any air flow impediment. Minimum Required Thread Size K Sprinkler Maximum Minimum Sprinkler Discharge inch (mm) Factor Spacing Distance Distance between ft. (m) to Wall ft. (m) sprinkler ft. (m) Flow Press. gpm (Lpm) psi (bar) W' (15mm) 4.3 12 x 12 (3.6x3.6) 6 (1.83) 8 (2.43) 12 (45) 7.8 (0.54) W' (15mm) 4.3 14 x 14 (4.3x4.3) 7 (2.13) 8 (2.43) 13 (49) 9.1 (0.63) W' (15mm) 4.3 16 x 16 (4.9x4.9) 8 (2.43) 8 (2.43) 13 (49) 9.1 (0.63) W' (15mm) 4.3 18 x 18 (5.5x5.5) 9 (2.74) 8 (2.43) 18 (68) 17.5 (1.21) W'i15mm\ 4.3 20 x 20 (6.0x6.0) 10 (3.05) 8 (2.43) 21 (79) 23.8 (1.64) Note: 1 bar = 100 Kpa 2. " Maintenance Model RFC43 Concealed Sprinklers should be inspected quarterly and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Remove any sprinkler cover plate assembly which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper operation or norwperati<:ln. Model RFC43 Residential Concealed Sprinkler Specification Sprinklers shall be cULus Listed low flow residential concealed sprinklers with drop-down deflector and adjustable flat cover f?late engineered for a minimum design density of 0.05 gpm/ff Sprinkler frame and deflector shall be of bronze frame construction having a W NPT thread. Thermal element shall consist of an approved black-painted beryllium-nickel fusible solder link with symmetric lever mechanism, maintaining a T eflon-coated Belleville spring washer and machined brass cap water seal assembly containing no plastic parts. Sprinkler K-factor shall be nominal 4.3 (62.4), having a 7/16" orifice. Temperature rating shall be Ordinary 1650F (740C); cover plate temperature rating to be 1350F (570C). Cover plate assembly shall consist of a brass cover plate and copper alloy retainer flange allowing a W I cover plate adjustment. Any secure engagement between the cover plate and the cup will assure that the drop-down deflector is properly located below the ceiling. A plastic protective cap shall be provided and factory installed inside the sprinkler cup to protect the drop-down sprinkler deflector from damage, which could occur during construction before the cover plate is installed. Standard cover finish: [Chrome] [White] [Specialty - specify]. Residential concealed sprinklers shall be Reliable Model RFC43, SIN RA0612 (Bulletin 006). Ordering Information Specify: 1. Sprinkler Model 2. Cover Plate Finish f" x 1/2" REDUCING 1 TEE OR ELBOW ~. UT--~h..- -[u III -'J . ... .u . ~--~'-~-r-~-t~N__- u-1L, r~--2i. [66.7mm} OM. ~.. [58.7mm} DIA - I HOLE IN CEILING CUP I 3ft" D1A. (84. fmm) t 2" [SO.8mm} MAX. FACE OF FITTING TO FACE OF C[lL/NG DIMCNSION I , 3/76" r {4.8mm} - COVER PLA T[: 1 /2" [ /2. tmm 7 ADJUSTMENT ow.'" 3. Cover Plate Finishes 111 Standard Finishes Chrome White Special Application Finishes Bright Brass Black Plating Black Paint Off White Satin Chrome (') Other colors and finishes available. Consult factory for details. Note: Paint or any other coatings applied over the factory finish will void all approvals and warranties. ~.. :J::I .. Reliable...For Complete Protection Reliable offers a wide selection of sprinkler components. Following are some of the many precision-made Reliable products"that guard life and property from fire around the clock. · Automatic sprinklers · Flush automatic sprinklers · Recessed automatic sprinklers · Concealed automatic sprinklers · Adjustable automatic sprinklers · Dry automatic sprinklers · Intermediate level sprinklers · Open sprinklers · Spray nozzles · Alarm valves · Retarding chambers · Dry pipe valves · Accelerators for dry pipe valves · Mechanical sprinkler alarms · Electrical sprinkler alarm switches · Water flow detectors · Deluge valves · Detector check valves · Check valves · Supertrol electrical system · Sprinkler emergency cabinets · Sprinkler wrenches · Sprinkler escutcheons and guards · Inspectors test connections · Sight drains · Ball drips and drum drips · Control valve seals · Air maintenance devices · Air compressors · Pressure gauges · Identification signs · Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances, whenever applicable. Products manufactured and distributed by RELIABLE have been protecting life and property for over 80 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by: The Reliable Automatic Sprinkler Co., Inc. (800) 431-1588 Sales Offices (800) 848-6051 Sales Fax (914) 668-3470 Corporate Offices www.reliablesprinkler.comlnternet Address ~ Recycled \V Paper Reliilbl~ Revision lines indicate updated or new data E.G. Printed in USA 4/05 PIN 9999970261 Reliabld Bulletin 416 Rev.A Reliable Riser - Residential CD c ~ :J ,f::>. -"'" (j) ::Il <D < )> Reliable Riser - Residential 1" (30mm), or 1~" (40mm), or 2" (50mm) manifold optional NFPA 13D/13R F eatu res: 1. Stainless Steel body construction. 2. All brass trim. 3. Factory assembled. 4. Factory pressure tested at 200 psi. (13.8 bar) 5. Choice of trim: · Basic Trim (Fig. 1). · Basic Trim with TestANDrain Valve Trim (Fig. 2) · Basic Trim with Pressure Relief (P.R.) Valve Trim (Fig. 3). 6. Choice of mounting options: · Supply / System lines support. · Support Bracket (to stud) (Figs. 4 & 5). · Recessed or Flush mount (to wood panel) (Fig. 6). 7. NPT (female x female) connections. . 8. Slim design allows for easy installation within 2 x 4 on 16 centers wood frame construction. 9. Dedicated UL Listed Water Flow Detector assures optimum sensitivity. Approvals & Listings 1. Listed by Underwriters Laboratories Inc. and UL Certified for Canada (cULus) 2. NYC MEA 258-93-E Fig. 1 Base Unit Rg.2 Base Unit with TestANDrain('; Valve Fig.3 Base Unit with Pressure Relief (P.R.) Valve Trim Fig.4 Base Unit with P.R. Valve Trim & Support Bracket The Reliable Automatic Sprinkler Co., Inc., 525 North MacQuesten Parkway, Mount Vernon, New York 10552 Optional Trims - Technical Data: Descri tion Manifold Size: Basic Trim P.R. Valve Trim Dimensions Weight* Dimensions Weight* Dimensions Weight* B Manifold Body \ ~ System A""'" '~'1 (s.' ! t I ~ Support Bracket Drain Ball Valve (Normally CLOSED) Drain Water Row Detector Product Description: The Reliable-Riser comes factory assembled with the necessary ac- cessories for a cost effective, yet complete riser assembly. Cast-on lettering clearly identifies manifold size, flow direction as well as the test and drain outlet, and UL listing control number 59UN. Note: TestANDrain trim (Fig. 2) offered with choice of manifolds [1 (30mm), 1'y;; (38mm) or 2 (50mm)] and three options of TestANDrain orifices each (% ,11'6 or,Y;;). -r 1/2" - MINIMUM CAP Fo.~ WATER FLON INDICATOR COVER REMOVAL(TYPICAL ALL MANiTOLDS) STUD SUPPORT BRAC.K[i MOl..'NT / / L BRACKET FLUSH WiTH FACE OF STUD Fig.5 TeStANDrain@ Valve Water flow detector contact ratings: 10 A @ 125/250 VAC Ordering Information: Specify: 1. Size 2. Trim type 3. Support bracket, if required Installation: 1. Install the manifold with the flow arrow pointing towards SYSTEM side using threaded connections. 2. Connect a 1 NPT drain line. Ensure the drain Ball Valve is in the CLOSED position. 3. Place the sprinkler system in service. Caution: Automatic sprinkler systems having non-fire pro- tection connection (permitting continual water flow) require dielectric fittings, according to NFPA 13 sect. 4-6, when dissimilar metal piping mater;- als are joined. Note: Use a non-hardening pipe joint compound, or tape. 5'UD- r ,:'0:0 ~~.I'1Ci. I ! I 1 . I.I~ fe, I .'-UL~'~ I LlL.J2U ~..6. I I~_- a;~.., ~ - -- _ _ -=-=-- .....------, />:-g _ 's-:~ _ -----, L - - - -if ~~ Jh--c= ~}-1-;:r~~-,- - - - - -, '" >-~ - . ~C.-. ,.)JI1 ('~i\ r- - - -,; ~'1L':;-'':' L _>." .... 1.'1'-- --L ' - "'" - u- t'":r~"\.'1 .~ -L --.J 0 = = = =-~~~\.>.~~) ,:;",'''Ct.~::; ';[CfS;,[;) ':,.'i FLUSH MQ'./NTfD Fig.6 The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association. Factory Mutual Research Corporation. or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 80 years. and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States. Canada and foreign countries. Manufactured by o Recycled \V Paper Rellabli The Reliable Automatic Sprinkler Co., Inc. (800) 431-1588 Sales Offices (800) 848--6051 Sales Fax (914) 668-3470 Corporate Offices www.reliablesprinkler.comlnternet Address Revision lines indicate updated or new data E.G. Printed in USA 6/02 P/N9999970207 - , Series 2000B Double Check Valve Assemblies Sizes: 1/2" - 2" (15 - 60mm) Features · Ease of maintenance with only one cover · Top entry · Replaceable seats and seat discs · Modular construction · Compact design · W' - 2" (15 - 50mm) Cast bronze body construction · Top mounted ball valve test cocks · Low pressure drop · No special tools required · %" - 1" (15 - 25 mm) have tee handles Available Models Suffix: B - Quarter turn ball valves LBV - less ball valves LH - locking handle ball valves (open position) SH - stainless steel ball valve handles HC - 2W' inlet/outlet fire hydrant fitting (2" valve) Prefix: U - union connections Pressure - Temperature Temperature Range: 330F - 1400F (50C - 60oC) Maximum Working Pressure: 175psi (12 bars) Standards ASSE Std. 1015, AWWA Std. C510 IAPMO PS31 , CSA B64.5 ES-A-2000B A AMES FIRE & WATERWORKS~ 2" 20008 He (50mm) 314"20008 (20mm) Series 2000B Double Check Valve Assemblies shall be installed at referenced cross-con- nections to prevent the backflow of polluted water into the potable water supply. Only those cross-connections identified by local inspection authorities as non-health hazard shall be allowed the use of an approved double check valve assembly. Check with local authority having jurisdiction regarding vertical orientation, frequency of testing or other installation requirements. These valves meet the requirements of ASSE Std. 1015 and AWWA Std. C510 and are approved by the Foundation for Cross-Connection Control and Hydraulic Research at the University of Southern California. Specifications A Double Check Valve Assembly shall be installed at each noted location. The assembly shall consist of two positive seating check modules with captured springs and rubber seat discs. The check module seats and seat discs shall be replaceable. Service of all internal components shall be through a single access cover secured with stainless steel bolts. The assembly shall also include two resilient seated isolation valves and four top mounted, re- silient seated test cocks. The assembly shall meet the requirements of ASSE Std. 1015 and AWWA Std. C510. Approved by the Foundation for Cross-Connection Control and Hydraulic Research at the University of Southern California. Assembly shall be an Ames Company Series 2000B Approvals ASSE, IAPMO, CSA, UPC ... Approved by the Foundation for Cross-Connection Control and Hydraulic Research at the University of Southern California. · Model LBV is not listed. u UL Classified (LBV models only) %" - 2" (19 - 50mm) Horizontal and vertical "flow up" approval on all sizes. e@@~@ Job Name Contractor Job Location Approval Contractor's P.O. No. Engineer Approval Representative Ames product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements. please contact Ames Technical Service. Ames reserves the right to change or modify product design. construction, specifications, or materials without prior notice and without incurring any obligation to make such changes and modifications on Ames products previously or subsequently sold. www.amesfirewater.com :- Dimensions - Weights ... A ~ Suffix He - Fire Hydrant Fittings dimension "A" = 23'12" (594mm) Dimensions Size (ON) A B C F G H I Weight Model in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm Ibs. koso 2000B \12 15 10 254 4% 117 2'l16 62 5 127 3% 85 2'116 59 2'116 52 4.5 2 2000B M3 % 20 11 Va 282 4 102 3Va 79 6'116 157 3'l16 B7 2Y, 54 1'116 33 5 2.3 2000B 1 25 13'/, 337 5'/, 130 4 102 7Y, 191 3Y, 85 1'Y'6 43 1''116 43 12 5.4 2000B 1Y, 32 16% 416 5 127 3'116 84 9\12 241 5 127 3 76 2 50 15 6.8 2000B 1Y, 40 16% 425 4'1a 124 3Y, 89 9Y, 24B 5'Y" 148 3Y, 79 2''116 68 15.86 7.2 2000B 2 50 19Y, 495 6'/4 159 4 102 13% 340 6Y, 156 3'l16 87 2''116 68 25.75 11.7 Strainer sold separately Capacities As compiled from documented Foundation for Cross-Connection Control and Hydraulic Research at the University of Southern California lab tests. "Typical maximum system flow rate (7.5 feet/sec., 2.3 meters/sec.) bars 1 III .8 ~ .7 ...J ~ .5 ::::l .4 l:l .3 ~ 1 a.' o bars psi ~" (15mm) * H It j I o 2 4 6 <1PO 7.6 15.2 22.8 5 7.5 1.52.3 bars psi ~"(20mm) Flow Rate * 1 I I 8 10 30.4 38 10 3.0 12 gpm 45.6 Ipm Ips mps bars l:l .8 .3 .7 ~ .5 iil .4 III ~ .3 a. .1 III 1.5 22 III .3 1.2 18 ~ .96 14 ::::l l:l .69 10 ~ .41 6 .14 2 <1P ~ -- 5 10 15 20 25 30 35 40 45 50 gpm 19 38 57 76 95 114 133 152 171 1901pm 7.5 15 Ips bars psi 2.3 4.6 mps .8 12 Flow Rate III 1" (25mm) * III .7 10 0 ...J .5 8 Gl .4 6 5 ~ III .3 4 ~.... III .1 2 ~ ~ a. 0 0 0 <1P 0 5 10 15 20 25 3D 35 40 45 50 55 60 gpm 19 38 57 76 95 114 133 152 171 190 209 228 Ipm 5 7.5 10 15 Ips 1.5 2.3 3.0 4.6 mps Flow Rate bars psi l:l 1.1 16 .3 .8 12 Gl .7 10 5 .5 8 l:l .4 6 ~ .3 4 a. .1 2 <1P ~ psi 14 12 10 8 6 4 2 o <1P 0 o 11/4" (32mm) * -- ./ - ~ ~ 10 20 3D 40 50 60 70 80 90 100 110 120 gpm 38 76 114 152 190 228 266 304 342 380 418 456 Ipm 5 7.5 10 15 Ips 1.5 2.3 3.0 4.6 mps Flow Rate 1112" (40mm) * psi 12 10 8 6 4 2 <1PO o ~ ......- ~ ..... 10 20 3D 40 50 60 70 80 90 100 110 120 gpm 38 76 114 152 190 228 266 304 342 380 418 456 Ipm 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps Flow Rate 2" (50mm) * --- 25 50 75 100 125 150 175 200 gpm 95 190 285 380 475 570 665 760 Ipm 5 7.5 10 15 Ips 1.5 2.3 3.0 4.6 mps Flow Rate A AMES FIRE&WATERWORKS A Division of Watts Regulator Company www.amesfirewater.com 1427 North Market Blvd. · Suite #9 · Sacramento, CA 95834 · Phone: 916-928-0123 . Fax: 916-928-9333 IMPORTANT: Inquire with governing authorities for local installation requirements. ES-A-2000B 0313 @Ames Co. 2003 Printed in U.S.A. Sheet l of c=, Sprinkler Systems Design Date 07/09/07 Job: AGGMRA01 PROJECT INFORMATION Job_ SERENITY HOUSE/AGGIES MOTEL REMODEL (2nd FLR. RESID. ROOMS) EAST 1st STREET AND ALBERT STREET, PORT ANGELES, WA. RA # 1 ------------------------------------------------------------------------- Occupancy_ _ _ _ _ _ _ _ _ _ _ _ LIGHT HAZARD/RESIDENTIAL Density_ _ _ _ _ _ _ _ _ _ _ _ _ 0.05 gpm/sq.ft. Area per Sprinkler _ _ _ _ _ _ _ VARIES Number of Sprinklers Calculated: 2 heads Authority having Jurisdiction_ _ NFPA-13 Hose _ _ _ _ _ 100.0 gpm Outside Hose System type_ _ Wet Water Supply _ 100.00 psi Static, 85.00 psi Residual @ 3032.0 gpm Sprinklers _ _ RELIABLE RFC43 CONCEALED RESID.PENDENT CALCULATION SUMMARY Demand_ _ _ _ _ 73.97 psi @ 42.8 gpm @ B.O.R. 75.55 psi @ 142.8 gpm @ Supply 99.95 psi available @ 142.8 gpm Demand is below curve by 24.40 psi Notes: 1"-2" THREADED EXPOSED PIPE IS DYNATHREAD 40. 1"-2" CONCEALED PIPE IS BLAZE- MASTER CPVC PIPE AND FITTINGS.NFPA 13-R DESIGN PER PA FIRE MARSHAL. FLOW TEST AT 1st AND ALBERT DATED 4/93 P/CITY OF PORT ANGELES. FP CONTRACTOR:KNIGHT FIRE PROTECTION 2509 W. 19TH STREET, PORT ANGELES, WA. PROGRAM: 'HydroCalc' by Micro Space Systems P.O. Box 5069, Glacier, WA 98244-5069 (509) 682-7043 .; . AGGMRAOi 07/09/07 1:29am Sheet 7. f" Pres sure (PS I ) .... lS N CSt UI ~ -..:J l!l CD Gl lJ) CSl w ~ .j:l. ~ CJ"I Gl CXl~ 5 .... .. . . . . ..; . . . .. . . . . .. .:" . . .. . . . .... ~ . ... . . . .... .; . .. . . . . .. . . 0:' ... . . . .. . . . ~... . . . .. . . . . ~ . . . . .. . . . . A:' . . . .. . . . . .. ~. . . .... . . . ~ : : : : : : : : : C'l . . . . . . . . - l:5l .... " . . . . ": . . .". . . . " ':' . . " . . . ." . ': . . " . . . . - . . : . -. . . . - . . ':' ". . . .". . . ': - . . . . - . . . ':" . . . ." . . . . ":' . . . - . . . . " ':' . . - . l:5l : : : : : : : : : N : : : : : : : : : .Ill . . . . . . . . - l:5l ...."....":... -. . . . - ':' . . -. . . .". ':' . -. . . . -. ': .". . . .". . ':' -' . . . -' . . ~". . . . -. . . ':"' . . .". . . . -:' . . . -. . "- l:5l : : : : : : : : . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CN N . . . . . . . . l:5l ...."....":... -. . . ." ':' . .". . . .". ':' . -. . . . -. ':' . -. . . . -. . ':' -. . . . -. . . ':-' . . . -. . . ':-' . . . -. . . . ":' . . l:5l : : : : : : : : . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Ill : : : : : : : rs : : : : : : : . .. rs .... .. . . . ..." . . . ... . . . .. ... . .... . . . .. . , . . .. . . . . .. . . , . .. . . . . .. . . 00' .. . . . . .. . . . .... . . . . .. . . . .,.. . .. ..... -.0 . . . .. . . . . .. ~. . . ... . . . . .. . l:5l "'t - o C .Ill CXl . . . . . . ~ .... .. . . . . .." . . .. ... . . ... . 00 . ... . . . . .. . .. . . .. . . . . .. . . , ... . . . . .. . . 00' .. . . . . ... . . . .... . . . l:5l . - . . - ... . . .,.. . . .... . . . ..... . . .... . . ....... . ..." . . .... UI -C'l ~l:5l ""'l:5l :% - . . . . ... . . .... . . . . ... . . . - . . . . ... . . . -... . .. . ... . . . .. -. . . ... . . . . ... . C'l .. .. . : . . . . : : l:5l .... ". . . . -, . . . - . . . . " '.' . . ". . . . ". , . . - . . . . - .. . - . . . . - . . '.' " . . . . - . . . ,- . . . . - . . . . ~ . . . . -. . . . ".' . . . - . . . . - ~. . . -. . . . - . l:5l CXl l:5l l:5l CD ....:I N . . CD ....".... -, . . . -. . . . - '.' . . -. . CD .. "'- . ... '\,. . ... . . . ... . , . ... . . . -. . ... .... . . . - . . . 'to -. . . . - . . . . ~ . . . . - . . . . -.. . . .... . . . - ..... . . ... . . . . ... . Static = 100.00 psi, Residual = 85.00 psi at a flow of 3032.0 gpm. Demand at BOR = 73.97 psi with 42.8 gpm flowing. System demand = 75.55 psi with 142.8 gpm flowing. Pressure available = 99.95 psi when 142.8 gpm is flowing. Demand is below curve by 24.40 psi. (24.4%) .... ~ Gl E: '" e'I'- I'DI -s I> c '" ... ... '" lr ... ... ... e'I'- IC ~ !: -S c I'DI ,.., Z .... . CX) CJI Ie! -s '" " ~ 'OJ Sheet '3/, Sprinkler Systems Design Description of Fitting abbreviations Code Description T Tee E Ninety degree elbow VE Victaulic ninety degree elbow PT Plastic Tee PE Plastic 90 degree Elbow PTR Plastic Tee flow thru run BKF Backflow preventor GV Gate valve UE Underground ASCA ninety degree elbow UEE Underground ASCA forty five degree elbow UT3 Underground ASCA tee: flow in bull, out one run only Description of Other abbreviations Code Description DR Drop BL Branch Line PT Total pressure PE Pressure loss due to elevation changes PF Pressure loss due to friction ^.5 Raised to the power of .5 (Square Root) A Actual pipe length F Fitting equivalent pipe length T Total pipe length ; AGGMRA01 07/09/07 1:30am Sheet 4./f:j Sprinkler Systems Design Sprinkler Systems Hydraulic Flow Calculations SERENITY HOUSE/AGGIES MOTEL REMODEL (2nd FLR. RESID. ROOMS) RA # 1 EAST 1st STREET AND ALBERT STREET, PORT ANGELES, WA. Raw data previous to any calculations No. Code Diam Length Kfac1 Kfac2 Press Elev Hose HW Vel Fittings 1 DR1 1.109 0.7 4.3 23.80 -0.75 0.0 150 32 1PT 2 DR2 1.109 0.7 4.3 9.10 -0.75 0.0 150 32 1PT 51 BL1 1.109 10.0 DR1 0.00 0.00 0.0 150 32 1PTR,lPE 52 BL1 1.109 34.5 DR2 0.00 0.00 0.0 150 32 3PTR,lPE 58 BL1 1.109 25.0 0.00 0.00 0.0 150 32 6PTR 59 BL1 1.400 46.0 0.00 0.00 0.0 150 32 10PTR,lPE 60 BL1 1.380 25.0 0.00 1.25 0.0 120 32 2E,lT 69 BU1 1.610 9.0 BL1 0.00 9.00 0.0 120 32 1E,lT 79 BU1 1.610 10.0 0.00 0.00 0.0 120 32 2E,lT 99 RI1 1.610 5.5 BU1 -6.0 0.00 5.50 0.0 120 32 1BKF 100 RI2 1.610 9.0 RI1 0.00 -1.50 0.0 120 32 4E,lT 101 UG1 4.026 6.0 RI2 0.00 3.50 0.0 120 32 1VE,lGV 102 UG2 4.070 97.0 UG1 0.00 0.00 0.0 150 32 1UEE, 1UE, 1GV, 1UT3 103 UG3 8.210 1.0 UG2 0.00 0.00 100.0 140 32 j AGGMRAOl 07/09/07 l:30am Sheet ~/' Sprinkler Systems Design Sprinkler Systems Hydraulic Flow Calculations SERENITY HOUSE/AGGIES MOTEL REMODEL (2nd FLR. RESID. ROOMS) EAST lst STREET AND ALBERT STREET, PORT ANGELES, WA. Discharge Node ( gpm) RA # 1 Node Detail-" Pressure Outlet (psi) K-Value Source Elevation (ft) Comments ================================================================================ 1 2 51 52 58 59 60 69 79 99 100 101 102 103 104 21.0 l3.0 2l.0 21.8 "100.0 23.80 9.10 23.88 25.18 37.13 45.45 50.97 56.69 61.98 63.69 72.44 73.97 75.49 75.55 75.55 Orif= 4.30 Orif= 4.30 K= 4.30 K= 4.35 DR1 DR2 17.00 17.00 17.75 17.75 17.75 17.75 17.75 16.50 7.50 7.50 2.00 3.50 0.00 0.00 0.00 Hose UG2 AGGMRA01 07/09/07 1:30am Sprinkler Systems Design Sprinkler Systems Hydraulic Flow Calculations Sheet (" / , SERENITY HOUSE/AGGIES MOTEL REMODEL (2nd FLR. RESID. ROOMS) EAST 1st STREET AND ALBERT STREET, PORT ANGELES, WA. Actual Pipe Diam Len No. (inch) (Ft) Pipe Detail-. Total Len (Ft) Elev Head (Ft) Fric Fric Flow Loss Loss Vel Nodes (Gpm) (Psi/Ft) (Psi) (Fps) Beg End RA # 1 Press @ Beg (Psi) Press @ End (Psi) 1 -------------------------------------------------------------------------------- -------------------------------------------------------------------------------- 23.88 2 1.11 Fit= 1.11 Fit= 1.11 Fit= 1.11 Fit= 1.11 Fit= 1.40 Fit= 1.38 Fit= 1.61 Fit= 1.61 Fit= 1.61 Fit= 1.61 Fit= 4.03 Fit= 4.07 Fit= 8.21 51 52 58 59 60 69 79 99 100 101 102 103 0.7 5.0 0.7 5.0 10.0 8.0 34.5 10.0 25.0 6.0 46.0 18.0 25.0 12.0 9.0 12.0 10.0 16.0 5.5 9.0 24.0 6.0 8.8 97.0 29.3 1.0 5.7 -0.75 1PT 5.7 -0.75 1PT 18.0 1PTR 1PE 44.5 3PTR 1PE 31.0 6PTR 64.0 0.00 10PTR 1PE 37.0 1.25 2E 1T 21.0 1E 1T 26.0 2E 1T 5.5 1BKF 33.0 -1.50 4E 1T 14.8 1VE 1GV 126.3 1UEE1UE 1.0 0.00 0.00 0.00 9.00 0.00 5.50 3.50 21.0 0.0717 13.0 0.0295 21.0 0.0719 0.41 0.17 1.29 7.0 4.3 7.0 42.8 0.2685 11.95 14.2 42.8 0.2685 42.8 0.0863 42.8 0.1399 42.8 0.0660 42.8 0.0660 42.8 0.0660 42.8 0.0660 42.8 0.0008 0.00 42.8 0.0005 1GV 1UT3 0.00 142.8 0.0002 8.32 14.2 5.52 5.18 1.39 1. 72 6.36 2.18 0.01 0.06 0.00 8.9 9.2 6.7 6.7 6.7 1 51 2 52 51 52 52 58 58 59 59 60 60 69 69 79 79 99 99 100 6.7 100 101 1.1 101 102 1.1 102 103 0.9 103 104 _____...t 23.80 9.10 23.88 25.18 37.13 45.45 50.97 56.69 61. 98 63.69 72.44 73.97 75.49 75.55 25.18 25.18 37.13 45.45 50.97 56.69 61.98 63.69 72.44 73.97 75.49 75.55 75.55 AGGMRAOl 07/09/07 1:30am Sheet 1{' Sprinkler Systems Design Sprinkler Systems Hydraulic Flow Calculations SERENITY HOUSE/AGGIES MOTEL REMODEL (2nd FLR. RESID. ROOMS) RA # 1 EAST 1st STREET AND ALBERT STREET, PORT ANGELES, WA. Pipe Flow Dia Fitting Length Fr Loss Press Hyd Vel No (gpm) (inch) and Dev (ft) (psi/ft) (psi) Ref (fps) Notes Drop 1 C = 150 ------- A 0.7 PT 23.80 1 ------- 21.0=4.30(23.80)^.5 F 5.0 PE -0.32 (EL= -0.75 ft) 1 21.0 1.11 1PT T 5.7 0.07175 PF 0.41 6.97 PT 23.88 51 Bl Jct K-factor for drop 1 = 21.0/ (23 .88) ^.5 = 4.30 Drop 2 C = 150 ------- A 0.7 PT 9.10 2 ------- 13.0=4.30(9.10)^.5 F 5.0 PE -0.32 (EL= -0.75 ft) 2 13.0 1.11 lPT T 5.7 0.02948 PF 0.17 4.31 PT 8.94 52 Bl Jct K-factor for drop 2 = 13.0/(8.94)^.5 = 4.35 . AGGMRAOl 07/09/07 1:30am Sprinkler Systems Design Sprinkler Systems Hydraulic Flow Calculations Sheet ~f~ SERENITY HOUSE/AGGIES MOTEL REMODEL (2nd FLR. RESID. ROOMS) EAST 1st STREET AND ALBERT STREET, PORT ANGELES, WA. RA # 1 Pipe Flow Dia Fitting No (gpm) (inch) and Dev Length Fr Loss (ft) (psi/ft) Branchline No. 1 51 A 21.0=4.30(23.88)~.5 F 21.0 1.11 IPTR 1PE T A 21.8=4.35(25.18)~.5 F 42.8 1.11 3PTR IPE T A F 6PTR T A F 1.40 10PTR 1PE T A F 2E IT T ---------------- ---------------- 52 58 42.8 1.11 59 42.8 60 42.8 1.38 10.0 8.0 18.0 34.5 10.0 44.5 25.0 6.0 31.0 46.0 18.0 64.0 25.0 12.0 37.0 PT PE 0.07189 PF PT PE 0.26851 PF PT PE 0.26851 PF PT PE 0.08632 PF PT PE 0.13991 PF PT Press (psi) 23.88 0.00 1.29 25.18 0.00 11.95 37.13 0.00 8.32 45.45 0.00 5.52 50.97 0.54 5.18 56.69 Hyd Vel Ref (fps) K-factor for branchline no. 1 = 42.8/(56.69)^.5 = 5.68 51 52 58 59 60 69 Notes C = 150 DR1 6.98 DR2 14.22 14.22 8.92 ** C = 120 ** (EL= 1. 25 ft) 9.18 Bulk Jct I AGGMR.AO~ 07/09/07 1:30am Sheet q f' Sprinkler Systems Design Sprinkler Systems Hydraulic Flow Calculations SERENITY HOUSE/AGGIES MOTEL REMODEL (2nd FLR. RESID. ROOMS) EAST 1st STREET AND ALBERT STREET, PORT ANGELES, WA. Pipe Flow Dia Fitting No (gpm) (inch) and Dev Bulk 69 A 42.8=5.68(56.69}^.5 F 42.8 1.61 1E 1T T A F 42.8 1.61 2E 1T T 79 Length Fr Loss (ft) (psi/ft) 9.0 12.0 21.0 10.0 16.0 26.0 PT PE 0.06601 PF PT PE 0.06601 PF PT K-factor for Bulk = 42.8/(63.69}^.5 = 5.36 Riser ----- ----- A F 1BKF T 99 42.8 1.61 Riser ----- ----- A F 4E 1T T 100 42.8 1.61 Under ground ------------ ------------ A F 1VE 1GV T 101 42.8 4.03 Under ground ------------ ------------ A F 1UEE 1UE T 1GV 1UT3 102 42.8 4.07 Under ground ------------ ------------ 100.0 gpm = Hose 103 142.8 8.21 5.5 PT 0.0 PE 5.5 0.06601 PF PT 9.0 PT 24.0 PE 33.0 0.06601 PF PT 6.0 PT 8.8 PE 14.8 0.00076 PF PT 97.0 PT 29.3 PE 126.3 0.00048 PF PT A F T 1.0 PT 0.0 PE 1.0 0.00017 PF PT RA # 1 Press (psi) Hyd Vel Ref (fps) Notes 56.69 3.90 1.39 61.98 0.00 1.72 63.69 63.69 2.38 6.36 72.44 100 69 C = 120 BL1 (EL= 9.00 ft) 6.75 72.44 100 -0.65 2.18 73.97 101 73.97 1.52 0.01 . 75.49 101 102 79 6.75 99 Top of Riser 75.49 102 0.00 0.06 75.55 103 99 C = 120 of Riser 5.50 ft} = 6.00# B.O.R. Top (EL= 6.75 1BKF C = 120 Top of Riser (EL= -1.50 ft) 6.75 B.O.R. (EL= 1.08 C = 120 B.O.R. 3 .50 ft) C = 150 B.O.R. 1.06 C = 140 B.O.R. 75.55 103 . 0.00 0.00 0.87 75.55 104 Supply Jet Available flow at 75.55 psi is 3948.4 gpm which is 3805.6 gpm from curve. Supply pressure available with 142.8 gpm flowing is 99.95 psi, thus system requirement is 24.40 psi below supply curve. (24.4%) J