HomeMy WebLinkAbout527 Rose St - Building CITY OF PORT ANGELES d` DEPARTMENT OF' COMMUNITY ECONOMIC DEVELOPMENT BUILDING DIVISION 321 EAST 5TH STREET, PORT ANGELES, WA 98362 Application Number 11- 00001327 Date 11/23/11 Application pin number 207758 Property Address 527 ROSE ST r ASSESSOR PARCEL NUMBER: 06- 30- 15 -5 -4- 0300 -0000- REPORT SALES TAX Application type description MECHANICAL APPL. PERMIT on your State excise tax form Subdivision Name Property Use to the City of Port Angeles Property Zoning RS9 RESDNTL SINGLE FAMILY (Location Code 0502) Application valuation 1000 Application desc Wood Stove Owner Contractor MELDRUM, ERIC L VERONICA OWNER 527 ROSE ST PORT ANGELES WA 983621922 Permit MECHANICAL PERMIT Additional desc WOOD STOVE Permit Fee 60.65 Plan Check Fee .00 Issue Date 11/23/11 Valuation 0 Expiration Date 5/21/12 Qty Unit Charge Per Extension BASE FEE 50.00 1.00 10.6500 EA ME- STOVE /FIREPLACE /MISC. APP. 10.65 Fee summary Charged Paid Credited Due Permit Fee Total 60.65 60.65 .00 .00 Plan Check Total .00 .00 .00 .00. Grand Total 60.65 60.65 .00 .00 Gt1N NOT t 1■) ST A 1 Separate Permits are required for electrical work, SEPA, Shoreline, ESA, utilities, private and public improvements, This permit becomes null and void if work or construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned for a period of 180 days after the work has commenced, or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of workpill be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construc ion. If 15 1,0/Mk: .c if Date Print Name Signature of Contractor or Authorized Agent Signature of Owner (if owner is builder) T:Forms /Building Division /Building Permit BUILDING PERMIT INSPECTION RECORD PLEASE PROVIDE A MINIMUM 24 -HOUR NOTICE FOR INSPECTIONS Building Inspections 417 -4815 Electrical Inspections 417 -4735 Public Works Utilities 417 -4831 Backflow Prevention inspections 417 -4886 IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT IN CONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE. Inspection Type Date Accepted By Comments FOUNDATION: Footings Stemwall Foundation Drainage Downspouts Piers Post Holes (Pole Bldgs.) PLUMBING: Under Floor Slab Rough -In Water Line (Meter to Bldg) Gas Line Back Flow Water FINAL Date Accepted b AIR SEAL: Walls Ceiling FRAMING: Joists Girders Under Floor Shear Wall Hold Downs Walls Roof Ceiling Drywall (Interior Braced Panel Only) T -Bar INSULATION: Stab Wall Floor Ceiling MECHANICAL: Heat Pump Furnace FAU Ducts Rough -In Gas Line Wood Stove Pellet Chimney Commercial Hood Ducts FINAL Date Accepted b/ MANUFACTURED HOMES: Footing Slab �1I Blocking Hold Downs s kirting._.. PLANNING DEPT. Separate Permit #s SEPA: Parking Lighting ESA: Landscaping SHORELINE: V FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/ USE Date Accepted B N Inspection Type P y 417 -4735 U.) Electrical V Construction R.W. PW En.ineerin• 417 -4831 V Fire 417 -4653 77A 417 -4750 1 v I Planning Building 417 -4815 •J• PROJECT STATUS UPDATE Permit I t� Date: Fj• 7. 17 1 phoned the: Applicant V t ca. ►-C/torVYnat t- S'1- t7 Property Owner at Contractor at eft a phone m -ss. qe, or discussed): The permit (has expired, 61 expire soo What is the status of this project? .se call and schedule a final inspection. •r u•mit a "permit extension request" letter. Or Let me know if the project is abandoned. e e C re-S ").2-1 World skov t if house Ca vt c&I perm T: Forms /Building Division/Project Status Update BUILDING PLUMBING MECHANICAL PERMIT APPLICATION SHORT FORM (To be used for projects that do not require plan review.) Date Receivgd t Permit V32L City of Port Angeles Please print in ink. Date Approve. -Z3 tl Attn: Building Permit Technician Approved by '-'111 321 E. 5 St., Port Angeles, WA 98362 360- 417 -4815 fax: 360- 417 -4711 Credit card payments are accepted Mon -Fri 8 -5 pm (no American Express) Hours: Mon through Fri 8 5 pm Cash checks are accepted Mon -Thurs 8:30 -4 pm Fri 8:30 -12:30 pm Contact person: 6n ica m e _I rum Phone:41-5d- 52 Property owner: w\ )a Phone: Property owner's mailing address: 5 l Por si g Contractor's business name: V��(' N`6 rU v1/1 Phone: (or property owner's name if he /she is doing overseeing the work) Contractor's mailing address: VIAL Contractor's L &I license number: Expiration date: Project Address: 5 0L gtse_ gun-- 11(-44-61 Project Type: w Residential D Commercial D Industrial D Multi- family Project Business Name: (for commercial, industrial, or multi family projects) The following permits are usually issued over the counter immediately, without the need for plan review. Complete only the portions of this permit that are relevant to your project. f Re -roof: house garage other tear off re -roof lay over one layer Licensed contractor: Submit a copy of your re -roof bid. Project Valuation (labor materials, not including sales tax) Re -side: house garage other Project Valuation (labor materials, not including sales tax) Repair: (explain the project) Project Valuation *Homeowner: If you will be doing overseeing the work, then the project valuation will be determined by doubling the cost of materials, to reflect the value the repair adds to your property. Cost of materials x 2 Project Valuation T:Forms /Building Division /Building /Plumbing /Mechanical Permit Application Short Form (Revised 2011) Page 1 of 2 Swimming Pool or Spa 24" deep): For prefabricated swimming pool or spa projects that do not require plan review: I Obtain.the.City of PA handout entitled "Pools Spas" follow the requirements. Project Valuation Demolition: A demolition permit is needed when an entire building gets demolished.' What will be demolished? house garage other Note: some demolition permit applications need to be reviewed by various City departments, and may take approximately two weeks to obtain. Agree to ensure that all utilities are /will be properly turned off (and capped off if needed) prior to demolition. Obtain (from the City of PA) an aerial view map of the parcel and put an "x" over the structure(s) to be demolished. Submit the map with this application. Obtain (from the City of PA) a copy of the Olympic Region Clean Air Agency (ORCAA) Demolition Permit Application. Contact ORCAA at 360- 417 -1466 to discuss whether or not an ORCAA Demolition Permit will also be needed. yes no Will the debris be going to the Regional Transfer Station in Port Angeles yes No If yes, will a licensed contractor be taking it there? If yes, obtain (from the City of PA) a copy of the Waste Disposal Application. Complete and submit the waste disposal application to the Building Permit Technician, now (or later if asbestos testing is needed). Plumbing Permit: (explain the project) Project Valuation Mechanical Permit: (explain the project) Project Valuation I have read and completed this application and know it to be true and correct. am auth to apply for this permit and understand that it is my responsibil1ty to determine what permits are required, and to obtain permits prior to working on projects. Date a/3/n Signature 0 J.t.1/� Print Name j eYytC.� ,fi 'rum Page 2of2 Application Number Application pin number Property Address ASSESSOR PARCEL NUMBER Application type description Subdivision Name Property Use Property Zoning Application valuation Application desc Garage subpanel with 6 circuits Owner Eric Meldrum 527 ROSE ST PORT ANGELES (360) 460 1781 Permit Additional desc Permit pin number Permit Fee Issue Date Expiration Date Qty 6 00 1 00 Unit Charge 2 0000 93 7500 Fee summary Charged Permit Fee Total Plan Check Total Grand Total INSPECTION TYPE DITCH SERVICE ROUGH IN FINAL COMMENTS WA 983621922 09 00001134 501890 527 ROSE ST 06 30 15 5 4 0300 0000 ELECTRICAL ONLY RS9 RESDNTL SINGLE FAMILY 0 Contractor OWNER ELECTRICAL ALTER RESIDENTIAL 155929 105 75 10/30/09 4/28/10 Per ECH ECH 105 75 00 105 75 ELECTRICAL PERMIT CITY OF PORT ANGELES 360-417-4735 Plan Check Fee Valuation EL BRANCH CIRCUIT W /FEEDER EL 0 200 SRV FEEDER Paid Credited 105 75 00 00 00 105 75 00 Date 10/30/09 DATE RESULTS 11/17(61 �P t I I t Extension 12 00 93 75 Due 00 00 00 00 0 Signature of owner or Electrical Contractor X Date INSPECTOR. .4( SAT 4* 6 e 4 •1111111/ is bnics ELECTRICAL INSPECTION WIRING REPORT 417 -4735 DATE PERMIT p INSPECTO i /4c) 9 OWN£RIC NTRACTOR g-RLG rlMA-D ZC)fr ADDRESS 527 APPROVED NOT APPROVED DITCH ROUGH IN /COVER SERVICE FINAL CQRRECTIONS NEEDED: tZ A)1\1 �-1� u`� 13 ALL 0-15 NIT') S Xis S) ricz 4M 0X /E,-- nps z ia, tL_k cM NOTIFY INSPECTOR WHEN CORRECTIONS ARE COMPLETED WITHIN 15 DAYS DO NOT REMOVE DATE OWN R/C j NTRAOTOR ADDRESS Z7 APPROVED 0 0 O. 0 G RECTIONS NEEDED* ELECTRICAL INSPECTION WIRING REPORT 417 -4735 PERMIT U INSPECTOR f LI7) DITCH ROUGH IN /COVER SERVICE FINAL NOT APPROVED 0 0 cif V 1 r D061TO g lit L._ jk( CoLUN ti 6 1" l e til I. E_E-- ►fin! iZ 7 �a 2 �rzt QI ,Lp >i 9 ■l t)s V. YE Cr at CAL. ut' `r co%%Z I.D1TM {Z o NOTIFY INSPECTOR WHEN CORRECTIONS ARE COMPLETED WITHIN 15 DAYS DO NOT REMOVE IRKS DATE (05 OWNER/CONT CTOR 1�i2 6- ADDRESS APPROVED 0 ELECTRICAL INSPECTION WIRING REPORT 417 -4735 PERMIT )34 III LD IZIJ V`N INSPECTOR NOT APPROVED DITCH ROUGH IN /COVER SERVICE FINAL CORRECTIONS NEEDED: C iZ Gic 5 j A=cFSs Ig6.r4 C'( F4 f 2.01 pi Carl DOc-`rd aX tz. AL. ca 06_176. tp M g OE. Irk 6A N I AIL V i t1 1 a r-- NOTIFY INSPECTOR WHEN CORRECTIONS ARE COMPLETED WITHIN 15 DAYS DO NOT REMOVE City of Port Angeles Permit Application Building Division /Electrical Inspections 321 East Fifth Street P.O. Box 1150 Port Angeles Washington, 98362 Ph: (360) 417 -4735 Fax: (360) 417-4711 Date: 70 �f 1 2 Single Family Dwelling Multi Family or Commercial* Commercial Addition I Alteration I Remodel Repair* Plan Review May Be Required, Please Complete Electrical Plan Review Information Sheet Job Address: Building Square Footage: Description of above Qj rf f tJ 171 6 REO.i J7..0O 1h Ago l> g__ Owner Information Contractor Information Name: Flit ic. L O2 U M Name: Mailing Address: 4 IZ,nSC. ST Mailing Address: City ___T_L* State' k)J Zip 9.6130 2 City State. Zip: Phone: ¥60 /78/ Fax: Phone. Fax: License Exp. License Exp. Unit Charge 93.75 $113.75 $160.00 $205.00 $291.25 2.00 57.50 2.00 72.50 86.25 $116.25 $131.25 75.00 69.00 75.00 50.00 50.00 93.75 80.00 86.25 27.50 57.50 86.25 43.75 Qty Owner as defined by RCW 19.28.261 (1) Owner will occupy the structure for two years after this electrical permit is finalized, (2) Owner is required to hire an electrical contractor if above said property is for sale, rent or lease. After reading the above statement; I hereby certify that I am the owner of the above named property or a licensed electrical contractor I am making the electrical installation or alteration in compliance with the electrical laws N.E.0 RCW Chapter 19.28, WAC Chapter 296.468, The City of Port Angeles Municipal Code, and Utility Specifications. Sir nature of owner electrical contractor or elect; :I administrator Total (Qtv Multiplied by Unit Charge) 9312 Service /Feeder 200 Amp. Service /Feeder 201 -400 Amp. Service /Feeder 401 -600 Amp. Service /Feeder 601 1000 Amp. Service /Feeder over 1000 Amp. $_12 92. Branch Circuit W/ Service Feeder Branch Circuit W/O Service Feeder Each Additional Branch Circuit Temp. Service/ Feeder 200 Amp. Temp. Service /Feeder 201 -400 Amp. Temp. Service /Feeder 401 -600 Amp. Temp. Service /Feeder 601 1000 Amp Portal to Portal Hourly Sign /Outline Lighting Signal Circuit/ Limited Energy Commercial Signal Circuit/ Limited Energy 1 2 Family Dwelling Signal Circuit/ Limited Energy Multi- Family Dwelling Manufactured Home Connection Renewable Electrical Energy 5KVA System or Less First 1300 Square Ft. Each Additional 500 Square Ft. or Portion of Each Outbuilding or Detached Garage Each Swimming Pool or Hot Tub Thermostat $,04 79 Total FO .-3o o1 RECEft.ED OCT 3 0 2009 ELECTRICAL INSPECTIONS Cash Check ;edit r'ard 8 t Vv CITY OF PORT ANGELES DEPARTMENT OF COMMUNITY ECONOMIC DEVELOPMENT BUILDING DIVISION 321 EAST 5TH STREET PORT ANGELES WA 98362 Application Number 09 00000565 Date 6/30/09 Application pin number 386255 Property Address 527 ROSE ST ASSESSOR PARCEL NUMBER 06 30 15 5 4 0300 0000 Tenant nbr name ERIC VERONICA MELDRUM Application type description RES ADDITION Subdivision Name Property Use Property Zoning RS9 RESDNTL SINGLE FAMILY Application valuation 84984 Application desc ADD ATTACHED GARAGE UPSTAIRS LIVING AREA ETC Owner Contractor ERIC L VERONICA MELDRUM OWNER 527 ROSE ST PORT ANGELES WA 983621922 (360) 460 1781 Structure Information 000 000 ADDING GARAGE UPSTAIRS LVNG AREA ETC Other struct info HARD SURFACE AREA TOTAL LOT COVERAGE 00 Permit BUILDING PERMIT RESIDENTIAL Additional desc ADDITION OF GARAGE /LIVING SPAC Permit pin number 148130 Permit Fee 915 25 Plan Check Fee 594 91 Issue Date 6/30/09 Valuation 84984 Expiration Date 12/27/09 Qty Unit Charge Per Extension BASE FEE 670 25 35 00 7 0000 THOU BL -50 001 100K (7 00 PER K) 245 00 Permit MECHANICAL PERMIT Additional desc Permit pin number 148619 Permit Fee 82 70 Plan Check Fee 00 Issue Date 6/30/09 Valuation 0 Expiration Date 12/27/09 Date Qty Unit Charge Per Extension BASE FEE 50 00 1 00 7 2500 EA ME VENT FAN (SINGLE DUCT) 7 25 1 00 10 6500 EA ME STOVE /FIREPLACE /MISC APP 10 65 1 00 14 8000 EA ME HEATER(SUSP /WALL /FLOOR MTD) 14 80 Permit PLUMBING PERMIT Additional desc Permit pin number 148627 Permit Fee 93 00 Plan Check Fee 00 Issue Date 6/30/09 Valuation 0 Expiration Date 12/27/09 Separate Permits are required for electrical work, SEPA, Shoreline, ESA, utilities, private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned fora period of 180 days after the work has commenced, or if required inspections have not been requested within 180 days from the last inspection I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. 13D o 'WOO (CC M J T:Forms/Building DivisionBuilding Permit Print Name Signature of Contractor or Authorized Agent Signature of Owner (if owner is builder) BUILDING PERMIT INSPECTION RECORD PLEASE PROVIDE A MINIMUM 24 -HOUR NOTICE FOR INSPECTIONS Building Inspections 417 4815 Electrical Inspections 417 4735 Public Works Utilities 417 4831 Backflow Prevention Inspections 417 4886 IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED POST PERMIT IN CONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE. Inspection Type Date FOUNDATION Footings Stemwall Foundation Drainage Downspouts Piers Post Holes (Pole Bldgs PLUMBING Under Floor Slab Rough -In Water Line (Meter to Bldg) Gas Line Back Flow Water AIR SEAL. Walls Ceiling FRAMING Joists Girders Under Floor Shear Wall Hold Downs Walls Roof Ceiling Drywall (Interior Braced Panel Only) T -Bar INSULATION. Slab Wall Floor Ceiling MECHANICAL. Heat Pump Furnace FAU Ducts Rough -In Gas Line Wood Stove Pellet Chimney Commercial Hood Ducts MANUFACTURED HOMES Footing Slab Blocking Hold Downs Skirting PLANNING DEPT Separate Permit #s SEPA. Parking Lighting I ESA. Landscaping I SHORELINE. FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/ USE Inspection Type Electrical 417 -4735 Construction R.W PW Engineering 417 -4831 Fire 417 -4653 Planning 417 -4750 Building 417 -4815 T.Forms /Building Division /Building Permit Accepted By Comments FINAL Date Accepted by FINAL Date Accepted by Date Accepted By CITY OF PORT ANGELES DEPARTMENT OF COMMUNITY ECONOMIC DEVELOPMENT BUILDING DIVISION 321 EAST 5TH STREET PORT ANGELES WA 98362 Application Number Application pin number Qty Unit Charge Per 3 00 1 00 1 00 Other Fees Fee summary T:FormsBuilding Division/Building Permit 7 0000 EA 7 0000 EA 15 0000 EA 09 00000565 386255 BASE FEE PL PLUMBING TRAP PL -WATER LINE PL -SEWER LINE Special Notes and Comments The Fire Department has reviewed the project application and has no comments June 26 2009 1 39 53 PM sroberds The proposal will result in construction of an attached garage to a sfr and a new deck resulting in 16% lot coverage and 32% site coverage No land use issues anticipated MAINTAIN CLEARANCES FROM SERVICE WIRES Electrical load calculations and electrical permits are required Any modifications to the City s electrical facilities will be at the customer s expense Public Works Utility Engineering has no requirements for this plan review Charged Paid Credited Page 2 Date 6/30/09 STATE SURCHARGE 4 50 Due Permit Fee Total 1090 95 1090 95 00 00 Plan Check Total 594 91 594 91 00 00 Other Fee Total 4 50 4 50 00 00 Grand Total 1690 36 1690 36 00 00 Extension 50 00 21 00 7 00 15 00 Separate Permits are required for electrical work, SEPA, Shoreline, ESA, utilities, private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned for a period of 180 days after the work has commenced, or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. Date Print Name Signature of Contractor or Authorized Agent Signature of Owner (if owner is builder) IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED POST PERMIT IN CONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE. Inspection Type FOUNDATION Footings Stemwall Foundation Drainage Downspouts Piers Post Holes (Pole Bldgs.) PLUMBING Under Floor Slab Rough -In Water Line (Meter to Bldg) Gas Line Back Flow Water AIR SEAL. Walls Ceiling FRAMING Joists Girders Under Floor Shear Wall) Hold Downs WallsT oof Ceiling Drywall (Interior Braced Panel Only) T -Bar INSULATION Slab Wall Floor Ceiling MECHANICAL. Heat Pump Furnace FAU Ducts Rough -In Gas Line Wood Stove Pellet Chimney Commercial Hood Ducts MANUFACTURED HOMES Footing Slab Blocking Hold Downs Skirting PLANNING DEPT Separate Permit #s Parking Lighting I Landscaping I Electrical Construction R.W PW Engineering Fire Planning Building T.FormslBuilding Division /Building Permit BUILDING PERMIT INSPECTION RECORD PLEASE PROVIDE A MINIMUM 24 -HOUR NOTICE FOR INSPECTIONS Building Inspections 417 4815 Electrical Inspections 417 4735 Public Works Utilities 417 4831 Backflow Prevention Inspections 417 4886 Date I —11— Oa Inspection Type Accepted By I Comments 'T =7 n4 3• L.L- I Cement 7_q -o Q 7Lt- FINAL Date 1 -1 (6/1 Accepted by I 'LL FINAL Date 'Accepted by 3 11-- SEPA. ESA. SHORELINE. FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/ USE 417 -4735 417 -4831 417 -4653 417 -4750 417 -4815 Date Accepted By O l- ZS- 1 1 I ALL O j1 0 L PREPARED 9/08/09 8 39 25 INSPECTION TICKET PAGE 3 CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 9/08/09 ADDRESS 527 ROSE ST SUBDIV TENANT NBR ERIC VERONICA MELDRUM CONTRACTOR PHONE OWNER ERIC L VERONICA MELDRUM PHONE (360) 460 1781 PARCEL 06 30 15 5 4 0300 0000 APPL NUMBER 09 00000565 RES ADDITION PERMIT BPR 00 BUILDING PERMIT RESIDENTIAL REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS BLFO 01 7/07/09 JLL 7/07/09 AP BCF 01 7/09/09 JLL 7/09/09 AP DSD 01 7/17/09 JLL 7/17/09 AP BL3 01 9/08/09 8L9 01 9/08/09 BLDG FOUNDATION TIME 09 00 July 7 2009 9 37 43 AM 1pangrle VERONICA 452 5280 FOUNDATION MORNING July 7 2009 4 31 07 PM jlierly BLDG CONCRETE FLOOR TIME 09 00 July 8 2009 3 57 26 PM 1pangrle VERONICA 452 5280 CEMENT MORNING July 9 2009 4 53 53 PM jlierly BLDG DOWN SPOUT DRAINS July 16 2009 9 19 40 AM 1pangrle VERONICA 452 5280 DOWNSPOUT DRAINAGE July 17 2009 4 06 26 PM jlierly BLDG FRAMING September 8 2009 8 37 29 AM 1pangrle VERONICA 452 5280 FRAMING BLDG SHEARWALL September 8 2009 8 36 27 AM 1pangrle VERONICA 452 5280 SHEARWALL COMMENTS AND NOTES PREPARED 7/29/09 8 59 58 INSPECTION TICKET PAGE 3 CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 7/29/09 ADDRESS 527 ROSE ST SUBDIV TENANT NBR ERIC VERONICA MELDRUM CONTRACTOR PHONE OWNER ERIC L VERONICA MELDRUM PHONE (360) 460 1781 PARCEL 06 30 15 5 4 0300 0000 APPL NUMBER 09 00000565 RES ADDITION PERMIT PL 00 PLUMBING PERMIT REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS PL2 01 7/28/09 JLL PLUMBING ROUGH IN TIME 01 00 7/28/09 DA July 28 2009 8 34 17 AM 1pangrle VERONICA 452 5280 PLUMBING ROUGH IN AFTERNOON July 28 2009 4 23 58 PM jlierly no water test on dwv plumbing layout is ok need test/j11 PL2 02 7/29/09 yj LL PLUMBING ROUGH IN TIME 01 00 July 29 2009 8 47 18 AM 1pangrle VERONICA 452 5280 ROUGH IN PLUMBING AFTERNOON COMMENTS AND NOTES PREPARED 7/28/09 8 37 55 INSPECTION TICKET CITY OF PORT ANGELES INSPECTOR JAMES LIERLY ADDRESS 527 ROSE ST TENANT NBR ERIC VERONICA MELDRUM CONTRACTOR OWNER ERIC L VERONICA MELDRUM PARCEL 06 30 15 5 4 0300 0000 APPL NUMBER 09 00000565 RES ADDITION PERMIT PL 00 PLUMBING PERMIT REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS SUBDIV PHONE PHONE (360) 460 1781 PL2 01 7/28/09 JLL PLUMBING ROUGH IN TIME 01 00 4-- 1,14.4 July 28 2009 8 34 17 AM 1pangrle VERONICA 452 5280 PLUMBING ROUGH IN AFTERNOON COMMENTS AND NOTES PAGE 4 DATE 7/28/09 PREPARED 7/17/09 8 24 03 INSPECTION TICKET PAGE 4 CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 7/17/09 ADDRESS 527 ROSE ST SUBDIV TENANT NBR ERIC VERONICA MELDRUM CONTRACTOR PHONE OWNER ERIC L VERONICA MELDRUM PHONE (360) 460 1781 PARCEL 06 30 15 5 4 0300 0000 APPL NUMBER 09 00000565 RES ADDITION PERMIT BPR 00 BUILDING PERMIT RESIDENTIAL REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS BLFO 01 7/07/09 JLL BLDG FOUNDATION TIME 09 00 7/07/09 AP July 7 2009 9 37 43 AM 1pangrle VERONICA 452 5280 FOUNDATION MORNING July 7 2009 4 31 07 PM jlierly BCE 01 7/09/09 JLL BLDG CONCRETE FLOOR TIME 09 00 7/09/09 AP July 8 2009 3 57 26 PM 1pangrle VERONICA 452 5280 CEMENT MORNING July 9 2009 4 53 53 PM jlierly DSD O1 7/17/09 BLDG 16 SPOUT DRAINS July 16 2009 9 9 9 19 40 AM 1pangrle VERONICA 452 5280 DOWNSPOUT DRAINAGE COMMENTS AND NOTES PREPARED 7/09/09 10 59 48 INSPECTION TICKET PAGE 6 CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 7/09/09 ADDRESS 527 ROSE ST SUBDIV TENANT NBR ERIC VERONICA MELDRUM CONTRACTOR PHONE OWNER ERIC L VERONICA MELDRUM PHONE (360) 460 1781 PARCEL 06 30 15 5 4 0300 0000 APPL NUMBER 09 00000565 RES ADDITION PERMIT BPR 00 BUILDING PERMIT RESIDENTIAL REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS BLFO 01 7/07/09 JLL BLDG FOUNDATION TIME 09 00 7/07/09 AP July 7 2009 9 37 43 AM 1pangrle VERONICA 452 5280 FOUNDATION MORNING July 7 2009 4 31 07 PM jlierly BCF 01 7/09/09 BLDG CONCRETE FLOOR TIME 09 00 July 8 2009 3 57 26 PM 1pangrle sk L VERONICA 452 5280 CEMENT MORNING COMMENTS AND NOTES PREPARED 7/07/09 9 42 02 INSPECTION TICKET PAGE 4 CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 7/07/09 ADDRESS 527 ROSE ST SUBDIV TENANT NBR ERIC VERONICA MELDRUM CONTRACTOR PHONE OWNER ERIC L VERONICA MELDRUM PHONE (360) 460 1781 PARCEL 06 30 15 5 4 0300 0000 APPL NUMBER 09 00000565 RES ADDITION PERMIT BPR 00 BUILDING PERMIT RESIDENTIAL REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS BLFO 01 7/07/09 JL BLDG FOUNDATION TIME 09 00 July 7 2009 9 37 43 AM 1pangrle i VERONICA 452 5280 FOUNDATION MORNING COMMENTS AND NOTES PREPARED 1/28/11 8 04 54 INSPECTION TICKET PAGE 2 CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 1/28/11 ADDRESS 527 ROSE ST TENANT NBR ERIC VERONICA MELDRUM CONTRACTOR OWNER ERIC L VERONICA MELDRUM PARCEL 06 30 15 5 4 0300 0000 APPL NUMBER 09 00000565 RES ADDITION REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS SUBDIV PHONE PHONE (360) 460 1781 November 16 2009 4 22 22 PM jlierly BL99 01 1/28/11 JLL BLDG FINAL TIME 01 00 January 25 2011 3 44 41 PM 1pangrle ERIC (RONNIE WIFE S #460 1781) BUILDING FINAL ADDED AN ATTACHED GARAGE UPSTAIRS LIVING AREA ETC AFTERNOON PERMIT ME 00 MECHANICAL PF REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS ME99 01 1/28/11 q L MECHANICAL FINAL TIME 01 00 ff 11 January 25 2011 3 46 16 PM 1pangrle I� ERIC (RONNIE WIFE S #460 1781) ME FINAL 1 AFTERNOON PERMIT PL 00 PLUMBING �E RMIT REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS PL2 01 7/28/09 JLL PLUMBING ROUGH IN TIME 01 00 7/28/09 DA July 28 2009 8 34 17 AM 1pangrle VERONICA 452 5280 PLUMBING ROUGH IN AFTERNOON July 28 2009 4 23 58 PM jlierly no water test on dwv plumbing layout is ok need test/j11 PL2 02 7/29/09 JLL PLUMBING ROUGH IN TIME 01 00 7/29/09 AP July 29 2009 8 47 18 AM 1pangrle VERONICA 452 5280 ROUGH IN PLUMBING AFTERNOON July 29 2009 4 28 38 PM jlierly PL99 01 1/28/11 f6L— PLUMBING FINAL TIME 01 00 January 25 2011 3 46 49 PM 1pangrle ERIC (RONNIE WIFE S #460 1781) PLUMBING FINAL AFTERNOON COMMENTS AND NOTES City Of Port Angeles Buildmg Dept. 321 E. 5 St. Port Angeles, WA 98362 To Whom It May Concern. We would like an extension of our building permit 09- 00000565 We are continuing the work ourselves and only have time on weekends. We only have a few things left and expect to be finished before the end of January 2011 Eric and Veronica Meldrum 527 Rose St. t7 Port Angeles, WA 98362 50 RECEIVED DEC 3 0 2010 CITY OF PORT ANGELES BUILDING DIVISION PREPARED 11/16/09 9 27 49 INSPECTION TICKET PAGE 3 CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 11/16/09 ADDRESS 527 ROSE ST SUBDIV TENANT NBR ERIC VERONICA MELDRUM CONTRACTOR PHONE OWNER ERIC L VERONICA MELDRUM PHONE (360) 460 1781 PARCEL 06 30 15 5 4 0300 0000 APPL NUMBER 09 00000565 RES ADDITION PERMIT BPR 00 BUILDING PERMIT RESIDENTIAL REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS BLFO 01 7/07/09 JLL BLDG FOUNDATION TIME 09 00 7/07/09 AP July 7 2009 9 37 43 AM 1pangrle VERONICA 452 5280 FOUNDATION MORNING July 7 2009 4 31 07 PM jlierly BCE 01 7/09/09 JLL BLDG CONCRETE FLOOR TIME 09 00 7/09/09 AP July 8 2009 3 57 26 PM 1pangrle VERONICA 452 5280 CEMENT MORNING July 9 2009 4 53 53 PM jlierly DSD 01 7/17/09 JLL BLDG DOWN SPOUT DRAINS 7/17/09 AP July 16 2009 9 19 40 AM 1pangrle VERONICA 452 5280 DOWNSPOUT DRAINAGE July 17 2009 4 06 26 PM jlierly BL3 01 9/08/09 JLL BLDG FRAMING 9/11/09 DA September 8 2009 8 37 29 AM 1pangrle VERONICA 452 5280 FRAMING September 11 2009 4 47 37 PM jlierly electrical inspection reqd 1st/j11 BL9 01 9/08/09 JLL BLDG SHEARWALL 9/11/09 AP September 8 2009 8 36 27 AM 1pangrle VERONICA 452 5280 SHEARWALL September 11 2009 4 47 27 PM jlierly BL3 02 11/09/09 JLL BLDG FRAMING TIME 01 00 11/09/09 AP November 9 2009 9 16 23 AM 1pangrle ERIC 452 5280 OR HIS WIFE RONNIE AT 460 1781 FRAMING AFTERNOON November 9 2009 3 58 50 PM jlierly BAIR 01 11/12/09 PB BLDG AIR SEAL TIME 09 00 11/12/09 AP November 12 2009 9 08 54 AM 1pangrle VERONICA 452 5280 OR 460 1781 AIRSEAL PLEASE INSPECT AS EARLY AS POSSIBLE INSULATORS ARE COMING TO INSTALL INSULATION TODAY November 12 2009 4 05 48 PM pbarthol BLI 01 11/16/09 JL BLDG INSULATION LI November 16 2009 8 54 34 AM 1pangrle VERONICA 452 5280 OR 460 1781 INSULATION COMMENTS AND NOTES PREPARED 11/12/09 9 10 38 INSPECTION TICKET PAGE 2 CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 11/12/09 ADDRESS 527 ROSE ST SUBDIV TENANT NBR ERIC VERONICA MELDRUM CONTRACTOR PHONE OWNER ERIC L VERONICA MELDRUM PHONE (360) 460 1781 PARCEL 06 30 15 5 4 0300 0000 APPL NUMBER 09 00000565 RES ADDITION PERMIT BPR 00 BUILDING PERMIT RESIDENTIAL REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS BLFO 01 7/07/09 JLL BLDG FOUNDATION TIME 09 00 7/07/09 AP July 7 2009 9 37 43 AM 1pangrle VERONICA 452 5280 FOUNDATION MORNING July 7 2009 4 31 07 PM jlierly BCF 01 7/09/09 JLL BLDG CONCRETE FLOOR TIME 09 00 7/09/09 AP July 8 2009 3 57 26 PM 1pangrle VERONICA 452 5280 CEMENT MORNING July 9 2009 4 53 53 PM jlierly DSD 01 7/17/09 JLL BLDG DOWN SPOUT DRAINS 7/17/09 AP July 16 2009 9 19 40 AM 1pangrle VERONICA 452 5280 DOWNSPOUT DRAINAGE July 17 2009 4 06 26 PM jlierly BL3 01 9/08/09 JLL BLDG FRAMING 9/11/09 DA September 8 2009 8 37 29 AM 1pangrle VERONICA 452 5280 FRAMING September 11 2009 4 47 37 PM jlierly electrical inspection reqd lst /j11 BL9 01 9/08/09 JLL BLDG SHEARWALL 9/11/09 AP September 8 2009 8 36 27 AM 1pangrle VERONICA 452 5280 SHEARWALL September 11 2009 4 47 27 PM jlierly BL3 02 11/09/09 JLL BLDG FRAMING TIME 01 00 11/09/09 AP November 9 2009 9 16 23 AM 1pangrle ERIC 452 5280 OR HIS WIFE RONNIE AT 460 1781 FRAMING AFTERNOON November 9 2009 3 58 50 PM jlierly BAIR 01 11/12/09 JLL BLDG AIR SEAL TIME 09 00 November 12 2009 9 08 54 AM 1pangrle (7/ VERONICA 4.,2 5280 OR 460 1781 AIRSEAL PLEASE INSPECT AS EARLY AS POSSIBLE INSULATORS ARE COMING TO INSTALL INSULATION TODAY COMMENTS AND NOTES PREPARED 11/09/09 9 17 56 INSPECTION TICKET PAGE 2 CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 11/09/09 ADDRESS 527 ROSE ST SUBDIV TENANT NBR ERIC VERONICA MELDRUM CONTRACTOR PHONE OWNER ERIC L VERONICA MELDRUM PHONE (360) 460 1781 PARCEL 06 30 15 5 4 0300 0000 APPL NUMBER 09 00000565 RES ADDITION PERMIT BPR 00 BUILDING PERMIT RESIDENTIAL REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS BLFO 01 7/07/09 JLL BLDG FOUNDATION TIME 09 00 7/07/09 AP July 7 2009 9 37 43 AM 1pangrle VERONICA 452 5280 FOUNDATION MORNING July 7 2009 4 31 07 PM jlierly BCE 01 7/09/09 JLL BLDG CONCRETE FLOOR TIME 09 00 7/09/09 AP July 8 2009 3 57 26 PM 1pangrle VERONICA 452 5280 CEMENT MORNING July 9 2009 4 53 53 PM jlierly DSD 01 7/17/09 JLL BLDG DOWN SPOUT DRAINS 7/17/09 AP July 16 2009 9 19 40 AM 1pangrle VERONICA 452 5280 DOWNSPOUT DRAINAGE July 17 2009 4 06 26 PM jlierly BL3 01 9/08/09 JLL BLDG FRAMING 9/11/09 DA September 8 2009 8 37 29 AM 1pangrle VERONICA 452 5280 FRAMING September 11 2009 4 47 37 PM jlierly electrical inspection reqd lst /jll BL9 01 9/08/09 JLL BLDG SHEARWALL 9/11/09 AP September 8 2009 8 36 27 AM 1pangrle VERONICA 452 5280 SHEARWALL September 11 2009 4 47 27 PM jlierly BL3 02 11/09/09 JLL BLDG FRAMING TIME 01 00 AA November 9 2009 9 16 23 AM 1pangrle ERIC 452 5280 OR HIS WIFE RONNIE AT 460 1781 FRAMING AFTERNOON COMMENTS AND NOTES BUILDING PERMIT APPLICATION Print in ink CITY OF PORT ANGELES Attn Building Permit Technician 321 E. Fifth St. Port Angeles WA 98362 (360) 417 -4815 fax (360) 41.7 -4711 Applicant Eric g, \mean, cc4 M. At.rii Property Owner 5a -e_ Property Owner's Address 5 .7 Contractor e'n S� Lc:- Contractor's Address /,4 License Expires E -mail Project Tvpe.& Brief De Check all that apply New Construction Addition Remodel Repair Demolition Re -roof Heat System Other Floor Areas scription. Existing (sq. ft.) Proposed (sq. ft.) jr�oV'- 56.30).5 e, 5 1 7_ -1 20 e 5 Basement 5/2_ 1 Floor 2 Floor 3 Floor Garage cke+6:61 att 5 30 Carport ,p.,epra J Covered Porch 12 Deck ccvo 2- 2 50 erlevei 1 Shed oft Other"tf 3 5iNc"Ivie 60 ro edr�o ISIL-r 10$01 -12o -i -13z. -50t 16o 3.654 TOTAL VALUATION Max height of proposed structures Z2- ft. Will a lawn sprinkler system be installed? $0 Will a fire sprinkler system be installed? dip Date Pon Name er 1 f I' I e. IroVli\ T Forms /Building Division /Bldg Permit.doc Occupancy group Occupant load Construction type .STLC Phone Phone For City Use On�Y I ate Approved Date Received CO 7 Permit O Sea 4 E °0 I Phone 4 5"Z -52_ 80 enc,meldfurn0 h Cvn PROJECT ADDRESS S2._"/ R 05 ST Parcel Number 06301 j 5 4 0 3 o o Q c O O Lot I O 3 oning. 251 ,Residential Multi family Commercial Industrial j vt tr A iin 2_ ear c 4Pr40-e J{J,'roral rivin 'pore e cz) vex red/001 1 s re Co y44 ,mil 5 i r► tik `re pl4/ 3 A44111 4 mo c r Fw LvIY1d 0t (t°� to i'7S @urt v� i ewoi sr�ta Cif rn� is pi r a Jlnp #1' House garage other yl tear off re -roof lay over one layer Heat pump wood- burnipg stove gas fireplace, pellet stove other &•cul Lilo ex.CFed pro•OP4 rt41) f ,1 10 ay by 15�F hyveway SPp Mg ps per sq ft. of bedrooms of full baths of half baths Signature f A E 1, 200 21, bac� /3'1584 it) e4 hh Total footprint of structures 3 to 5 41- sq ft. Lot size 2.2 1 4 9 sq ft. Lot coverage I (e Site Coverage the amount of impervious surface on a parcel including structures paved driveways, sidewalks, patios, and other impervious surfaces. _(see PAMC 17 94 135 for exemptions) (�o t 5F) Site coverage 31 1 5' 3 d I have read and completed this application and know it to be true and cor ect. I am authorized to apply for this permit and understand that it is my responsibility to determine what permits are re uired, and to obtain permits odor to working on projects. ci 546 515 59 9 -520' b'; 1 -Rose St- �1. 526 1 527 527 .527 3830 4017 606 812' ��I I 5 z. __7 ,kp3._-'-, ,s±t_t_i__ 1 l _4 f fit— 1 _H 11 i i 1 4 -T L F-o v ------i r-17 i 1 1 i 1 ii 2. i T t -4- 1 r 1 I f 1 1 --i -L- l• 1-• r t 1 1 1 t— 4- 1 -4 --4-+ f I_ I ,----i 1 t 1 1 1 10 4 4- -4- 4- I I i I t t --4 -4 1 4-(11r-h op1- i ..c.t c:CPQ IN _4--_ t 4—- 30- I-- 24 i 4 v .6 texs k 1 __--.4---.77.=.” -4- 4- 1 4 F A 2- 7 E As 5 6- utre 15 u I I* -tr i 1 1 4_ 1 --T--- 1 .1 N-•=1 1_ fit 1 ___26 1 t 1 fo fe 14%. E IY19 G-cirgraJt_ Fr16'1 I t i 61: i 1 1 de ell mi.- i tht W ,N i'- 1 3 1 4 r (000 sP) 14o' 1 -4 if Propei 43 Afes, r CITY GOVERNMENT Lot: SZ i12 DiE. SF Address City: E. r i l4vQ S State L 1 Zip q 85k7_ Ve V1 &Jr�� 34©- 46© -17 R. Contact. Phone Phone 2 FAX Unlimited Group R -3 IV and R -4 Occupancies Only PRESCRIPTIVE APPROACH SIMPLE FORM For the Washington State Energy Code (2006 Edition) Climate Zone 1 Site Information. Table 6 -1 PRESCRIPTIVE REQUIREMENTS FOR GROUP R OCCUPANCY CLIMATE ZONE 1 (Unlimited Glazing Option Only) T Forms /Building Division /Prescriptive Approach- Simple Form Building Department Use Only Permit Notes O Wall )teno eIOW% Grade 0 35 0:58 0.20 R 38 R 30 R 21 R -21' R 10 This Project complies with the following: The project is a single family residence or duplex. The project is a wood frame OR all of the insulation is interior or exterior of the framing. All building components meet the requirements listed above 'V The project will meet all other provisions of the WSEC and VIAQ The Project will take advantage of the following exceptions to the prescriptive option. 602.6 Exception 2. One unlabeled or untested exterior swinging door 24 sq.ft. or less; may be installed per unit for ornamental, security, or architectural purposes. Location of the door taking this exception 602.6 Exception 2. If a door is mostly glass, it should meet the requirement glazing U factor listed above. Loc of the door() taking exception F e vie elect b ed rev 1 e de my d €c 1C r>n dirt in y re ryi Type of Heat Source if ie?/ ri R -30 R 10 of the vertical 1 iv, 1 e 611 i 1� l/ ft± az) nq 13 516 514 520 r Ro se •St 526 527 530 ,J4°1 3839 C-243 100A c/o r* 5 F 25K -603 3 84,1 612 STAMP LIMITATIONS NTI Engineering and Land Surveying has performed lateral structural analysis for plan sheets 1 thru 5 of 5 This addition to a single family residence is to be located at 527 Rose St., Port Angeles, WA 98362, TPN 063015- 540300 -0000 This analysis applies to this specific SFR addition only Eric Ronnie Meldrum provided these plans. The hand noted changes to these plans correspond with the calculations prepared by Catherine R. Bailey, stamped, signed, and dated 6 -16 -09 This stamp certifies only the hand written notations regarding the lateral forces and their corresponding Engineered changes to the Architectural drawings. RECEIVED JUN 1 7 2009 CITY OF PORT ANGELES BUILDING DIVISION 05p in 4-6 Rr Structural Calculations Meldrum Residence Addition 527 Rose St. Port Angeles, WA 98362 NT/ www. nti4u. com NTI ENGINEERING LAND SURVEYING 717 SOUTH PEABODY STREET PORT ANGELES, WA 98362 Engineers Land Surveyors Geologists Construction Inspection Materials Testing (360) 452 -8491 FAX 452 -8498 E -Mail: nfo@nli4u.com For PREPARED FOR: Eric Ronnie Meldrum 527 Rose St. Port Angeles, WA 98362 E -Mail: ericmeldrum @hotmail (360) 452 -5280 NTI JOB NUMBER MELE0901 *'LIMITATIONS** RECEIVED JUN 1 7 2009 CITY IDING DIVISION ANGELES NTI Engineering Land Surveying has been retained in limited capacity for this project. Both Design and Calculations have been based on information provided by the client, who is solely responsible for the accuracy of said information. The Engineer assumes no responsibility or liability for any element of this project not specifically addressed in or by these calculations, totalling I 4 sheets (including this cover), nor is any responsibility to be assigned to the Engineer Any alterations to the design of this project MUST be brought to the attention of the engineer for consideration as to the impact that they will have to the engineered design. Any and all deviations from the engineered design, not approved in writing by the engineer will make these calculations NULL and VOID The signature on the 'Oriainal Set' of calculations will appear in Blue ink :54 EST.. ii S.0 T C A E.E TS1 oRrs mitt vs I•-0 tal L,, ODD _E RIC Z.RONtE M ...as **JOIE D Vi0WoOm0 0Y1 MOWN rr NA 4 Zo-o9 I XT. E.R1 OR E. LE VAT. I ON.S PLANNING G SERAcE Pon,. 6. of 3 MECAWind Version 2 0 2 7 per ASCE 7 -05 Developed by MECA Enterprises Inc Copyright 2009 www mecaenterorises com Date 6/9/2009 Company Name Address City State File Location C \Program Basic Wind Speed(V) Structural Category Natural Frequency Importance Factor Alpha At Am Cc Epsilon Slope of Roof Ht Mean Roof Ht RHt Ridge Ht OH Roof Overhang at 2 Bldg Length Along Rid ge 30 00 ft Bldg Width Across Ridge= 24 00 ft Main Wind Force Resisting System(MWFRS) Figure 6 -5 Internal Pressure Coefficients for Buildings GCpi Enclosed Bldg +GCpi 0 18 Enclosed Bldg -GCpi -0 18 Figure 6 -6 External Pressure Coefficients Cp Loads on Main Wind -Force Resisting Systems(Method 2) MWFRS -Wall Pressures Perpendicular to Ridge Wall Leeward Walls Side Walls Top Elev Bot Elev Kz Kzt ft ft 22 00 20 00 10 00 12 00 10 00 00 0 0 0 92 90 85 Roof Location Windward Min Cp Windward Max Cp Leeward Perp to Ridge Overhang Top (Windward) Overhang Top (Leeward) Overhang (Windward only) Project No Designed By Description Customer Name Proj Location Files \MECAWind \Default wnd 1 1 1 Eave= Cp O 50 O 70 00 00 00 11 81 4 78 15 13 8 10 User Input 100 00 'mph II N/A 1 00 9 50 0 11 0 15 0 20 0 20 4 62 12 19 50 ft 22 00 ft 1 00 ft qz Windward Wall Total psf +GCpi GCpi GCpi 20 02 19 63 18 47 Cp 0 55 0 07 0 60 0 55 0 60 0 80 MWFRS -Wall Pressures Parallel 10 10 9 83 9 05 to Ridge 17 13 16 86 16 07 GCpi(psf) 12 64 4 68 13 47 9 13 9 96 12 90 Data Structure Type Exposure Category Flexible Structure Kd Directional Factor Zg Bt Bm 1 Zmin Slope of Roof(Theta) Type of Roof Eht Eave Height Roof Area +GCpi(psf) GCpi(psf) 21 91 21 64 20 86 Note 1) Total Leeward GCPi Windward GCPi 2) Shear and Moment are sum of forces (Leeward +Windard) acting at Bot Elev GCpi(psf) 5 61 2 35 6 44 9 13 9 96 12 90 Shear Moment Kip K ft 1 3 1 3 7 8 46 9 14 1 156 3 Building C No 0 85 900 00 ft 1 00 0 65 500 00 ft 15 00 ft 21 04 Deg Gabled 17 00 ft 836 00 ft" 3 a-P i3 Wall Cp GCpi(psf) GCpi(psf) Leeward Walls 0 45 10 98 3 95 Side Walls -0 70 -15 13 8 10 Top Elev Bot Elev Kz Kzt qz Windward Wall Total Shear Moment ft ft psf +GCpi GCpi -GCpi Kip K ft 22 00 12 00 0 92 1 00 20 02 10 10 17 13 21 08 20 00 10 00 0 90 1 00 19 63 9 83 16 86 20 81 10 00 00 0 85 1 00 18 47 9 05 16 07 20 03 Note 1) Total Leeward GCPi Windward GCPi 2) Shear and Moment are sum of forces (Leeward +Windard) acting at Bot Elev Roof Dist from Windward Edge 0 0 ft to 9 8 ft 9 8 ft to 19 5 ft 19 5 ft to 30 0 ft 1 0 6 0 10 8 Cp GCpi(psf) GCpi(psf) 0 95 -0 84 0 56 19 29 -12 26 17 45 10 42 12 81 5 78 1 0 36 1 120 2 Wind Pressure on Components and Cladding Width of Pressure Coefficient Zone "a" 3 ft Description Width Span Area Zone Max Min Max P Min P ft ft ft GCp GCp psf psf truss 2 0.0 24 00 192 00 3 0 300 -2 000 10 000 42 555 faCE,PIES17 T Fs &XS }OM, Th Tv9. Of3V41. L1 1 1 gj i I I II I I 1 r I I I I I I I I 1 I F .3 =IS- Fr'' I I 1=3 0 _Id I I I 4 0.9 0 GI LA I I irb N I 5-ASK° N r L\ 0 41 t Fix 4t4-.F"'• 42.41.; ___J 4.'-i$` _.I 0 11 1 30 0' I 2' 0 w CAT'. .1 9.-0 gEmove mstew LE6C A k 5 6 42 I.JALL TyPe v 1, I APPGOVZO -09 kot..t, Dio) ER\COZONWE MELDRUM ORGyoli 1) P ER LEVEL F LOCM ?J LA j ,SECINAC-E.S P"m"""4""°' Poc Ar`�I�s, t Sfs -FA. 00S r„ 5, 3 S4o1 0bt 6 5 SrKs �3 C� 13�� U 75 5,, X13 ().7a6 Q r Des,�� C��e�r i� k_ E, i =1 k (..s I., Asc ?o5 i )q.g E0 I 19-h Ace-E TO /V1 -1L6 L M 5 -0(9 E t lc V r (}t t l V 1 1 1 V SC-E v'IN Os I/J V° �SDS 1 I (6175) s Vteljk N/ SEIS4+ IC o 04) W-i' (w4,11)(io -6) 33.9 j,■f VSO S If G -/-1# /w 5EISMcc_ r. Suv aS YIs/5 T3 R I I DESIGNED BY CAI) I PROJECT me( FOR: L n lY V I SHT: 5 OF og11 [3 (11psf ',2 wet I�C1oPs�) DATE. 6- i5' 09 (\1 t21 c>r c u NTI o,( W 1)ES( -Er)c, 4e. 614.ss Day' U �N Cnw4t..- i- c -vA.4. 90 2691 2, g \F 30 Gvv\.v 2ry Somr41 NTI Engineering Surveying Northwestern Territories, Inc. Engineers Land Surveyors Geologists Materials Testing 717 SOUTH PEABODY PORT ANGELES, WASHINGTON 98362 (360) 452-8491 www.nti4u.com info @nti4u.com NT/ Project: Meldrum Addition Client: Eric Ronnie Meldrum By CRB Job No MERE0901 S./7 15(30 -6) Wall Description Location. Grid Line 1 Number of Stories 1 First Floor Wall Height 0.00 (ft) Second Floor Wall Height 8.00 (ft) Second Floor Thickness 12 (in) Shear Panel Length 4.00 (ft) Total Shear Wall in Wall Line 14.00 (ft) Roof Dead Load 12.00 (psf) Floor Dead Load 12.00 (psf) Wall Dead Load 10.00 (psf) Roof Tributary Width 2.00 (ft) Floor Tributary Width 0.00 (ft) Loads Load Type W (wind) E (Seismic) W Wall Line Shear Load Roof 6737 (Ib) Floor /Roof (single story) (lb) Results Wall Shear v Overturning Moment M Resistive Moment M Tension, (Ib) 0-P 13 481 (plf) 15399 ft-lb 832 ft -lb 3710 (Ib) NTI ENGINEERING LAND SURVEYING 717 SOUTH PEABODY STREET PORT ANGELES, WA 98362 Engineers Land Surveyors Geologists Construction Inspection Materials Testing (360) 452 -8491 FAX 452 -8498 E -Mail: info@nti4u.com Roof Tributary Width 2 (ft) 1925 (lb) �r 'r A 0 o FloorTributary 11 Width 0 (ft) 0 (Ib),7 Shear Wall to be Designed °o 4 T 3710 (Ib) v (ft) C 3710 (Ib) Single Sided Use 7116' Sht'g with 8d 4112 Good For 532 plf Use Simpson MST60 Good For 4830 Ib, 18' Clear, 46 -16d Commons 0 1- r iG NT/ Project: Meldrum Addition Client: Eric Ronnie Me!drum By CRB Job No MERE0901 S./T /R. 15(30 -6) Wall Description Location. Grid Line 2 Number of Stories 1 First Floor Wall Height 0.00 (ft) Second Floor Wall Height 8.00 (ft) Second Floor Thickness 12 (in) Shear Panel Length 5.50 (ft) Total Shear Wall in Wall Line 20.00 (ft) Roof Dead Load 12.00 (psf) Floor Dead Load 12.00 (psf) Wall Dead Load 10.00 (psf) Roof Tributary Width 2.00 (ft) Floor Tributary Width 0.00 (ft) Loads Load Type W (wind) E (Seismic) W Wall Line Shear Load Roof 2694 (Ib) Floor /Roof (single story) (Ib) Results Wall Shear v Overturning Moment M Resistive Moment M Tension (Ib) 7 oxt3 135 (plf) 5927 ft -lb 1573 ft -lb 886 (Ib) Holdown Not Required NTI ENGINEERING LAND SURVEYING 717 SOUTH PEABODY STREET PORT ANGELES, WA 98362 Engineers Land Surveyors Geologists Construction Inspection Materials Testing (360) 452 -8491 FAX 452- 8498 E -Mail: info @nti4u.com Roof Tributary Width 2 (ft) 741 (lb)vir i 1 A FloorTributary Width 0 (lb) �r Shear Wall to be Designed o 55 T 886 (Ib) (ft) C 886 (Ib) Single Sided Use 7/16' Sht'g with 8d 6/12 Good For 364 plf o 0 (ft) F r NTI Project: Meldrum Addition Client: Eric Ronnie Meldrum By CRB Job No MERE0901 S./17R. 15(30 -6) Wall Description Location. Grid Line 3 Number of Stories 1 First Floor Wall Height 0.00 (ft) Second Floor Wall Height 8.00 (ft) Second Floor Thickness 12 (in) Shear Panel Length 6.50 (ft) Total Shear Wall in Wall Line 13.00 (ft) Roof Dead Load 12.00 (psf) Floor Dead Load 12.00 (psf) Wall Dead Load 10.00 (psf) Roof Tributary Width 2.00 (ft) Floor Tributary Width 0.00 (ft) Loads Load Type, W (wind) E (Seismic) W Wall Line Shear Load Roof 2694 (Ib) Floor /Roof (single story) (Ib) Results Wall Shear v Overturning Moment M Resistive Moment M Tension (Ib) 207 (plf) 10776 ft-lb 2197 ft -lb 1431 (lb) NTI ENGINEERING LAND SURVEYING 717 SOUTH PEABODY STREET PORT ANGELES, WA 98362 Engineers Land Surveyors Geologists Construction Inspection Materials Testing (360) 452 -8491 FAX 452 -8498 E -Mail: info@nti4u.com Roof Tributary Width 2 (ft) 1347 (lb) 4. �r A 0 0 co FloorTributary 11 Width 0 (ft) E 0 (lb) r L Shear Wall to be Designed o° A 0 4 65 T 1431 (lb) v (ft) C 1431 (Ib) Single Sided Use 7/16' Sht'g with 8d 6/12 Good For 364 plf Use Simpson MST37 Good For 2465 lb, 18' Clear, 20 -16d Commons NO REM. Act f 1 4 1° 32 wow. c° 3 x. t '7 0' E T 900E (2,8 0 1 UV. 1 3t 1 v- rti P 9 7° driD. D91. TYP I 0f11.2. ■018Dfl, 41 1 C) (C.) I rs N REPI_Pce 9x' c.- ra. 1 COT DA. 05 MG Cf, EM ST,GE oV .1% I._ Ati i I 30 CY ex 4 To 'NANG...10MS FS731 8M. s.0t4cr4e. Evsl. woon DEcx. LO.) kves t.Otat.P■A110 .9 WEI LEGEdtit A\ 5HE4tkwAi-t- Ty% i .toLt,t)c)...w E.P, c t. RONNIE MELDRUM IA r_ 1 0 OV: 00AVIN VI RUft A t 3. 0 9 IIIMPIOD 7- .L0 Vi E R LEVEL FLOOR OLAR w.c....e.L.A4SSAIAG SER43 us. L..00,ds (C Ai Floor A//s se G 09r E-)Li' �l� s�) s s' (il K pri) -1 �f o 1 g a e I -'(3v w-- ssg- ss g% 6Jw 5ersty, i 9 /[3o 'lam p sr) 4 )00 ir 040 1 8 O S� (jr t A 19 f 1 (.3O -Ve PS SHT OF /013 873 S I S T JO R G I DATE. /5 09 J I DESIGNED BY CAP IV PROJECT me kk, on FOR. Erie- r' r y L 111L. I/44a,rA 3r L)e ftk £)vr J NTI 33 e 1� Gvn ueyv drt,.!✓ r It s 4 a; 5 oO f w4 7 17 /40)/ 2J �3 SpIP Ce) ✓1: tieyv*--4 rJ k"1-4. 1 Silki NTI Engineering Surveying Northwestern Territories, Inc. Engineers Land Surveyors Geologists Materials Testing 717 SOUTH PEABODY PORT ANGELES, WASHINGTON 98362 (360) 452 -8491 www.nti4u.com info@nti4u.com NT/ Project: Meldrum Addition Client: Eric Ronnie Meldrum By CRB Job No MERE0901 S./T /R. 15(30 -6) Wall Description Location Grid Line 4 Number of Stories 2 First Floor Wall Height 8.00 (ft) Second Floor Wall Height 8.00 (ft) Second Floor Thickness 12 (in) Shear Panel Length 4.00 (ft) Total Shear Wall in Wall Line 14.00 (ft) Roof Dead Load 12.00 (psf) Floor Dead Load 12.00 (psf) Wall Dead Load 10.00 (psf) Roof Tributary Width 2.00 (ft) Floor Tributary Width 2.00 (ft) Loads Load Type, W (wind) E (Seismic) W Wall Line Shear Load Roof 6794 (Ib) Floor /Roof (single story) 5587 (Ib) Results Wall Shear v Overturning Moment M Resistive Moment M Tension (Ib) 884 (plf) 45749 ft -lb 1743 ft -lb 11145 (Ib) NTI ENGINEERING LAND SURVEYING 717 SOUTH PEABODY STREET PORT ANGELES, WA 98362 Engineers Land Surveyors Geologists Construction Inspection Materials Testing (360) 452 -8491 FAX 452- 8498 E -Mail: info@nti4u.com Roof Tributary Width 2 (ft) 1941 (lb) 4. rn rn 0 FloorTributary Width 2 (ft) 1596 (Ib) r' i Shear Wall to be Designed A 0 0 CO 4 T 11145 (Ib) r (ft) C 11145 (lb) Double Sided Use 7116' Sht'g with 8d 4112 Good For 1064 plf Use Simpson HDU11 Good For 11175 Ib,1 AB, 7' Embed, 8x Stud F w NT/ Project: Meldrum Addition Client: Eric Ronnie Meldrum By CRB Job No MERE0901 S./T /R. 15(30 -6) Wall Description Location Grid Line 5 Number of Stories 2 First Floor Wall Height 8.00 (ft) Second Floor Wall Height 8.00 (ft) Second Floor Thickness 12 (in) Shear Panel Length 25.00 (ft) Total Shear Wall in Wall Line 25.00 (ft) Roof Dead Load 12.00 (psf) Floor Dead Load 12.00 (psf) Wall Dead Load 10.00 (psf) Roof Tributary Width 2.00 (ft) Floor Tributary Width 12.00 (ft) Loads Load Type, W (wind) E (Seismic) W Wall Line Shear Load Roof 2694 (Ib) Floor /Roof (single story) 2235 (Ib) Results Wall Shear v Overturning Moment M Resistive Moment M Tension, (Ib) (D. of 13 197 (plf) 63650 ft -lb 105592 ft -lb -284 (Ib) Holdown Not Required NTI ENGINEERING LAND SURVEYING 717 SOUTH PEABODY STREET PORT ANGELES, WA 98362 Engineers Land Surveyors Geologists Construction Inspection Materials Testing (360) 452 -8491 FAX 452 -8498 E -Mail: info @nti4u.coro Roof Tributary Width 2 (ft) 2694 (Ib) i i rn co co FloorTributary 1 Width 12 (ft) 2235 (lb) v Shear Wall to be Designed o ao 25 T 284 (Ib) y (ft) C 284 (Ib) Single Sided Use 7/16' Sht'g with 8d 6/12 Good For 364 plf F V Project: Meldrum Addition Client: Eric Ronnie Meldrum By CRB Job No MERE0901 S./T /R. 15(30 -6) Wall Description Location. Grid Line 6 Number of Stories 2 First Floor Wall Height 8.00 (ft) Second Floor Wall Height 8.00 (ft) Second Floor Thickness 12 (in) Shear Panel Length 2.00 (ft) Results Wall Shear v Overturning Moment M Resistive Moment M Tension, (lb) NTI 779 (plf) 20111 ft -lb 676 ft -lb 9829 (Ib) NTI ENGINEERING LAND SURVEYING Use Simpson HD10A Good For 9900 Ib, SSTB28, 6x Stud 717 SOUTH PEABODY STREET PORT ANGELES, WA 98362 Engineers Land Surveyors Geologists Construction Inspection Materials Testing (360) 452 -8491 FAX 452 -8498 E -Mail: info @nti4u.com Total Shear Wall in Wall Line 6.33 (ft) Roof Tributary Width 2 (ft) Roof Dead Load 12.00 (psf) 851 (Ib) 4r 4 i Floor Dead Load 12.00 (psf) Wall Dead Load 10.00 (psf) Roof Tributary Width 2.00 (ft) cp Floor Tributary Width 12.00 (ft) c0 FloorTributary Width 12 (ft) Loads 706 (lb) 4 4, 4 Load Type W (wind) E (Seismic) W Wall Line Shear Load Roof 2694 (Ib) Floor /Roof (single story) 2235 (lb) Shear Wall to be Designed o 2 T 9829 (Ib) (ft) C 9829 (lb) Single Sided Use 7/16' Sht'g with 10d 0 3/12 Good For 840 plf cc 1- CITY OF PORT ANGELES LIGHT DEPARTMENT ELECTRICAL PERMIT N? 16337 (; -/ ,., ~ Port Angeles, WashlngtolLm....................-'............m...m................ 19.....:.. In accordance with the City Ordinance to regulate the Installation. extension. or repair of elec- trical equipment in. on, or about any building or other structure In the City of Port Angeles, per- mission is hereby granted to do' electrical work as listed below. Address ...,..i.:::;>...'2.:.:;.l1::~o:1:-::..,.1'!:~;..qf?........m....m....... Occupancy........t:L€..,.~...................... .7"'?': ' -P .,.:;: . Owner .............!.',U?.'~!~:7,7....L~j/........l;;;.i:/.....c..>'<Tenant.....m.................................m.............................. Wiring Contractor .....Z.~.f.-:O:..::~::.::.1.....,..:~...:.~,~P.......... By............m..............m............m....................... ~ j . ,.1 /.2-0/;;1((1 Light Outlets...................:m_....n....._..... Service. volts ....._mnn-:-..__..n.....m_.__.n. <7'0 .3 - RecePt~cle OUtlet6~.m!.~-...-.........--n-. No. wires n~'"j?4;;p."-;J'; Dryer, KW...._................__.....__________n_. SIze wires.......:.._..:...n....._n.._.._....,_. /.:L //"",.; r.-:- A- Range. KW..............:................... Main fuse ........../-..t"............... Water Heater: /'" Enclosure m((........l?........... y;~ KW................!'............................. . r..c; (, 158- Heat. KW.......__n.........._......__.nn___n_..._ Type of wirIng: Entrance Cable _....00......__............_. Motors: size. volts and phase: / tI2"'~:J- .-.--;,-.-----.-.--..----....-............--....---...-..... Rigid Conduit ............ Metallic TUbing __moo CUrrent transformers: No. & Size............n...n................n_. ::::;,.:;:el.?;/!.;.,:;.~:;.::::::::::::::: - ~ .. SeT. NO.....n.._...................._................ ____..~.:!.~-.;.c~~.~.:........ SeT. No. ............................................. SeT. No. ..__00_000000.00_..00__0000._00.........00_.. Type of Wiring: Armored Cable ..........._...m_..n....__. Non-Metallic ....................___.....00___ Knob & Tube_nnnn......................._ Rigid Conduit ............................... Metallic Tubing m_m_..._m............ Raceway _._...._......................._._..._ Circuits. LighL./..9........................ Utility ...../...:2............................ i ,.,! :::::..~:~~;::::;:.::::......:.....:..: . r: Motor ._...___....___...........__.........__...... Dryer_....Annn_...n...................._..... Furnace _n.n._n.._.......h..._~nn_..__n....._.. 7";: Total wad............................. SeT. NO...........n..........n_.nn_......_....... Total .u...~n....~...nnn--n..-n-nn Remarks: hd.......d..O..___d___.....d.~_:=:_::':::::....d.(~!.-db:;tI.Lo.~.._________..___m...___m....._.m.mO.__..__.____________ .:.:.:i:~i.o~_...O....O.......h~...---O...::~.~O~:O~~~.~.~~O~O~~o~o.......mo..---m---::..:~J(l:..Jldl~::~2~:~~ NOTICE-Current must n~ be turned on until Certificate of Inspection has been issued. It work is to be con. cealed due notice must be given the Inspector so that work may be inspected before concealment. NOTIFY THE INSPECTOR BY PERMIT NUMBER WHEN READY FOR INSPECTION ELECTRICAL PERMIT Address ~- Owner ......nn_.__...n____.nu......._..n..n.._.......:.:...._.._n.....n..un.....___..........n..........n............ Tenant.....nnn.n._nnu._nu._nnn....n_.nn....n__.nn_n.._. Date..__..._______.___._._..........;......_.....~_...:..._. N? 16337 Wiring Contractor........n.....nn......................n_....__..n_.........nnn................................................... By.._...n___.._._....n...............__.....___...n_.....n__ J NOTICE---Current must not be turned on untn Cert1!1cate of Inspection has been issued. It work Is to be con- ~cealed due nouimust he given the Inspector so that work may he inspected helore concealment. .J 1M -'Olympic Printers, Inc. .