HomeMy WebLinkAbout819 W 10th St - BuildingPREPARED 9/24/07 10 35 23 INSPECTION TICKET PAGE 11 CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 9/24/07 ADDRESS 819 W 10TH ST SUBDIV TENANT NBR LAYNE FREHNER CONTRACTOR PHONE OWNER LAYNE PEGGY FREHNER PHONE (360) 452 4933 PARCEL 06 30 00 0 2 9975 0000 APPL NUMBER 07 00000593 RES REMODEL PERMIT TYP /SQ BL1 01 9/24/07 BPR 00 BUILDING PERMIT RESIDENTIAL REQUESTED INSP DESCRIPTION COMPLETED RESULT RESULTS /COMMENTS BLDG FOUNDATION FOOTING 09/24/2007 08 55 AM LPANGRLE LANE 461 9385 FOOTING COMMENTS AND NOTES PREPARED 7/27/09 8 22 09 INSPECTION TICKET PAGE 1 CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 7/27/09 ADDRESS 819 W 10TH ST SUBDIV TENANT NBR LAYNE FREHNER CONTRACTOR PHONE OWNER LAYNE PEGGY FREHNER PHONE (360) 452 4933 PARCEL 06 30 00 0 2 9975 0000 APPL NUMBER 07 00000593 RES REMODEL PERMIT BPR 00 BUILDING PERMIT RESIDENTIAL REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS BL1 01 9/24/07 JLL BLDG FOUNDATION FOOTING 9/24/07 AP 09/24/2007 08 55 AM LPANGRLE LANE 461 9385 FOOTING 09/24/2007 04 29 PM JLIERLY BL99 01 7/27/09 J L BLDG FINAL July 24 2009 3 55 49 PM 1pangrle I CALLED THE OWNER LAYNE AT 460 7851 TO FINAL THIS PERMIT HE SAID THE WORK IS DONE HE THOUGHT IT WAS ALREADY FINALED BLDG FINAL REPAIR OR REPLACE MAIN BEAMS POSTS JOISTS UNDER HOME BRING HOME BACK TO LEVEL RE SKIRT PERIMETER OF HOME PUT IN NEW PADS FOR POSTS REMOVE SOIL UNDER HOME FOR PROPER CLEARANCE RE ROOF LAYNE SAID TO KNOCK ON THE DOOR AND LET THE TENANT MARGARET KNOW YOU ARE THERE TO DO A CITY INSPECTION COMMENTS AND NOTES CITY OF PORT ANGELES r1� DEPARTMENT OF COMMUNITY DEVELOPMENT BUILDING DIVISION O v 321 EAST 5TH STREET PORT ANGELES, WA 98362 Application Number 07 00000593 Date 6/22/07 Application pin number 444034 Property Address 819 W 10TH ST ASSESSOR PARCEL NUMBER 06 30 00 0 2 9975 0000 Tenant nbr name LAYNE FREHNER Application type description RES REMODEL Subdivision Name Property Use Property Zoning RS7 RESDNTL SINGLE FAMILY Application valuation 12000 Owner Contractor LAYNE PEGGY FREHNER 112 RESERVOIR RD PORT ANGELES WA 98363 (360) 452 4933 OWNER Permit BUILDING PERMIT RESIDENTIAL Additional desc FOUNDATION RPR RE ROOF Permit pin number 102707 Permit Fee 235 75 Plan Check Fee 94 30 Issue Date 6/22/07 Valuation 12000 Expiration Date 12/19/07 Qty Unit Charge Per Extension BASE FEE 95 75 10 00 14 0000 THOU BL -2001 25K (14 PER K) 140 00 Special Notes and Comments 06/12/2007 11 56 AM SROBERDS The proposal will result in the repair /remodel of a sfr in the RS 7 zone No land use issues anticipated Other Fees Fee summary Signature of Contractor or Authorized Agent T• \Policies \1102_I5 building permit inspection record05 wpd [1/4/2005] STATE SURCHARGE 4 50 Charged Paid Credited Due Permit Fee Total 235 75 235 75 00 00 Plan Check Total 94 30 94 30 00 00 Other Fee Total 4 50 4 50 00 00 Grand Total 334 55 334 55 00 00 Separate Permits are required for electrical work, SEPA, Shoreline ESA, utilities private and public improvements This permit becomes null and void if work or construction authorized is not commenced within 180 days if construction or work is suspended or abandoned for a period of 180 days after the work as commenced or if required inspections have not been requested within 180 days from the last inspection I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. Date Signatu A owner is builder) FIh 7-2 7 01 Date 6 FOUNDATION: FOOTINGS SHEAR WALLS WALLS FOUNDATION DRAINAGE DOWN SPOUTS PIERS POST HOLES (POLE BLDGS.) PLUMBING UNDERFLOOR /SLAB ROUGH -IN WATER LINE (METER TO BLDG) GAS LINE BACK FLOW WATER AIR SEAL WALLS CEILING FRAMING JOISTS GIRDERS SHEAR WALL /HOLD DOWNS WALLS ROOF CEILING DRYWALL (INTERIOR BRACED PANEL ONLY) T -BAR INSULATION SLAB WALL FLOOR CEILING MECHANICAL ROUGH -IN HEAT PUMP /FURNACE /DUCTS GAS LINE WOOD STOVE PELLET CHIMNEY CALL 417-4815 FOR BUILDING INSPECTIONS. CALL 417 -473 FOR ELECTRICAL INSPECTIONS CALL 417-4807 FOR PUBLIC WORKS UTILITIES PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED 4ND ACCEPTED POST PERMIT IN A CONSPICUOUS LOCATION KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE. INSPECTION TYPE DATE ACCEPTED COMMENTS YES I NO MANUFACTURED HOMES FOOTING SLAB BLOCKING &HOLD DOWNS SKIRTING PLANNING DEPT SEPARATE PERMIT #'s PARKING /LIGHTING LANDSCAPING RESIDENTIAL ELECTRICAL LIGHT DEPT BUILDING PERMIT INSPECTION RECORD 9 -2 l T! LI CONSTRUCTION R.W PW/ ENGINEERING 417 -4807 FIRE 417 -4653 I I I I PLANNING DEPT 417 -4750 I p I I BUILDING 417 -4815 I i ^21 -0 1 I •12.- I T \Policies \l 102 15 building permit inspection record05.wpd [1/4/2005] FINAL FINAL SEPA. ESA. SHORELINE: DATE ACCEPTED BY. DATE ACCEPTED BY. FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE DATE YES NO COMMERCIAL DATE I ACCEPTED I YES I NO I 417 -4735 ELECTRICAL LIGHT DEPT CONSTRUCTION R.W PW ENGINEERING I FIRE DEPT I PLANNING DEPT I BUILDING I I I I I I I I I Applicant or Agent: LAI VA Owner t/i Address: //Z Architect/Engineer Contract Address: A PROJECT ADDRESS g! 9' LEGAL DESCRIPTION Lot: /6 CLALLAM COUNTY PARCEL NUMBER. 4 b',� 000 2 9 9 7-) TYPE OF WORK. Residential New Constr Re -roof Stove Multi- family Addition Move Garage Commercial Remodel Demolition Deck Repair Sign Other BRIEF DESCRIPTION OF THE PROJECT A, ,6,f JJ 7'c v R 1 BUILDING PERMIT jiAitit 0 4 LEI, S IDENTIAL. Occupancy Group- No. of Stories: Lot Size: S Total lot coverage PLANNING USE ONLY ESA/Wetland(s) 0 Yes No SEPA Checklist required? Yes No Other VALUATION OF CONSTRUCTION In all cases, a valuation amount must be entered by the applicant. This figure will be reviewed and may be revised by the Building Division to comply with current fee schedules. Contact the Permit Coordinator at 417 -4815 for assistance. PLAN CHECK FEE. IF a plan check fee is due it must be submitted at the time the building permit application and construction plans are submitted. All other permit fees are due at the time of permit issuance. EXPIRATION OF PLAN REVIEW If no permit is issued within 180 days of the date of application, the application will expire. The Building Official can extend the time for action by the applicant up to 180 days upon written request by the applicant (see Section R105.3.2 of the International Building/Residential Code, 2003). No application can be extended more than once. I hereby certify that I have read and examined this apple apply for this permit and understand that it is m must obtain such permits prior to work. T \FORMS\BldgPermitAppl. wpd Applic Fill out COMPLETELY and in INK. Your COMPLETE to be accepted for review PERMITS (360) 417 -4815 Re Cit ion and sibility to APPLICATION application and site plan MUST B If you have any questions, call FAX(360)417 -4711 360 460. -1261 CAI Phone: 33a z 4 Phone: ?4o 95z f<933 Phone: State License It T 7 Phone:/ City A f WA' Zip: 983‘ /Q f ---S5 1 3"94-74// ZONING. .s63 Block: 2. 9 9 Subdivision. 74 1/ Existing Ft. ,V,, Proposed Sq. Ft. I4110r'aoS4?" W(1 Goan SIZE/VALUATION SF /SF SF /SF SF /SF agtp /ice TOTAL VALUATION /2, ,ao. FS /t -dzg #c fr7. /s To,s/s 'ti. '.t! Aw Occupant Load: Construction Type: More TOTAL Sq. Ft._7 g ow the same to be true and correct. I am authorized to ermine what permits are required ,not the City's, and that I Date: FOR OFFICIAL USE ONLY Date Rec. O 5 Z3 b Permit to Approved: ate Issued: Zip: 13 ‘3 3*- zz -d7 7 7 (7-0 APPRO PLAN hz /1A BLDG. DPWU FIRE. OTHER. 4 I BLOCK Z9 9 TOWNSITE of PORT ANGELES This sketch is provided. without charge. for your information. It is not intended to show all matters related to the property including, but not limited to, area, dimensions, easements, encroachments or location of boundaries. It is not part of, nor does it modify the commitment or policy to which it is attached. The Company assumes NO LIABILrlYfor any matter related to this sketch. Reference should be made to an accurate survey for further information. ANCHOR 7' MIN. EMBEDMENT CRAWL SPACE i- 3' CLEARANCE Ti BENT VERTICAL REINFORCEMENT TIED IN PLACE TO HORIZONTAL/ REINFORCEMENT VERTICAL REINFORCEMENT BEND =12 X BAR DIA. #4 BAR 6' BEND 6' MIN. TO UN- TREATE ATERIAL WALL THICKNESS 6' THICK FOR WALLS UNDER 6' HIGH 8' THICK FOR WALLS OVER 6' HIGH ANCHOR BOLTS FOR 1 -STORY 72' O. C. 2 STORY 48' O. C. PLACE BOLTS WITHIN 12' OF EACH PLATE END USE 3 "X3 "X114' SQ. WASHERS UNDER NUTS 3' CLEARANCE BL 1102_08IRC.WPD FOOTING WIDTH 12' 1 -STORY 15' 2 -STORY 23' 3 -STORY MONOLITHIC CONCRETE FOUNDATION DETAIL NO SCALE 'AACHOR 47' MIN. EMBEDMEN 2003 INTERNATIONAL BUILDING CODE CONCRETE FOUNDATION WALL FOOTING DETAIL FOOTING WIDTH 12' 1 -STORY 15' 2 -STORY 23' 3 -STORY *2' D EPFOOTING *2' TO 4 BELOW GRADE INTO 4' TO LESS UNDISTURBED THEN 6' SOIL 12' 1 -STORY 18' 2 -STORY PRESSURE TREATED SILL PLATES 4 HORIZONTAL REINFORCEMENT PLACED WITHIN 12' OF TOP OF WALL FINISH GRADE REINFORCEMENT SCHEDULE HEIGHT IN FEET *6' TO 8 >8 FOOTING THICKNESS 1 -STORY 6' 2- STORY'' 3 -STORY 8 1/2' 6' MIN. TO UN- TREATED MATERIAL JIIIt {II� lffl MIN. FOOTING DEPTH BELOW GRADE INTO UNDISTURBED SOIL 12' 1 -STORY 18' 2 -STORY VERTICAL REINFORCEMENT HORIZONTAL REINFORCEMENT I #4 48 0 C I (1) #4 TOP BAR I #4@ 48' 0 C #4 @24 0 C #4 24 0 C I #4 18 0 C I #4 @24 O C I #4 10 O C ENGINEERS ANALYSIS WITH STAMPED SIGNED PLAN REQUIRED VERTICAL REINFORCEMENT MUST BE BENT F. TIED TO FOOTING REINFORCEMENT REINFORCEMENT SHALL BE GRADE 60- HYDRAULIC BENT ONLY #4 REINFORCEMENT 2- PIECES CONTINUOUS 1 /2 ANCHOR BOLTS(SAME AS ABOVE) PRESSURE TREATED SILL PLATES #4 REINFORCEMENT 1 -PIECE CONTINUOUS FINISH GRADE I i #4 REINFORCEMENT 2 PIECES CONTINUOUS \NAME crr( Of PORT N The Issuance o cations and otl from thereatte plans, specific building opera violation c a U (SECTION Approval Date 41 jl H (t EXPERIMENT N0. If 7 *it \tegbASSaieriatentAarawarea ria on inuomossaararryrovesseas se ilt 1111111110 11,411111rtaigmelf,0111111111101111111111 Ili IRV IIIIIIMIN01111111011111W4 #110111011111111111 111111 Ili, 111111111111111111011116%001510101111114111111 SO Stillifititatittalvtillsolavimmulawgia pi? iittma gaitateSSISS IOS.:20110012littlalitii INS IOSSSOONSU MUMWSISSORMOSSISI 96115500000100111180.1.100MOSSISSO SI 11101111111111115011111111111111111111111111111110111111111111211111 Si 111111111111111111111011111111111111111111111111011111111111111 a 01111111111111111111111111111101111111111111111111111111011111111111 II ti!IS111111111 1 11 0111111111111111 0111111111111111r111111111111111111111* 401111111111001111111111110M1111111111101111111110111111 MI 1111811111111111110011111111111111111111111111011111110101111 MS 11111111111110111111110110111111111111111101111110110111 I 11111111111111151101111201111211111111111110101111111011111 I 001010110101111111111121111000110easra,liiima 1 01111111Wiromos satia11111111111001111110 irlse owxt:VPIrsg vXr iAVSVstwm,.„_- IIIIV CMagiisisatsir tksstttclgiaIMSWLSIIIIII iii 11110111111111 11110010110000,111111111111111 11111111161100010 101111110111 1111110 vslE V& rf 1111111L r look fir 14 0, ON LN3N1t134X3 Ai i A ELECTRICAL PERMIT AND INSPECTION RECORD CITY OF PORT ANGELES 361 -417 -4735 Application Number Application pin number Property Address ASSESSOR PARCEL NUMBER Tenant nbr name Application type Subdivision Name Property Use Property Zoning Application valuation description 07 00000593 444034 819 W 10TH ST 06 30 00 0 2 9975 0000 LAYNE FREHNER RES REMODEL RS7 RESDNTL SINGLE FAMILY 12000 Owner Contractor LAYNE PEGGY FREHNER OWNER 112 RESERVOIR RD PORT ANGELES WA 98363 (360) 452 4933 Permit ELECTRICAL ALTER RESIDENTIAL Additional desc ANGELES EL 1 4 CIR RELOCATE Permit pin number 113001 Sub Contractor ANGELES ELECTRIC Permit Fee 46 00 Issue Date 10/24/07 Expiration Date 4/21/08 Qty Unit Charge 1 00 46 0000 Plan Check Fee 00 Valuation 0 Per Extension ECH EL R OR RM 1 4 ALT CIRCUITS 46 00 Special Notes and Comments 06/12/2007 11 56 AM SROBERDS The proposal will result in the repair /remodel of a sfr in the RS 7 zone No land use issues anticipated Other Fees Fee summary Permit Fee Total Plan Check Total Other Fee Total Grand Total Charged 46 00 00 4 50 50 50 STATE SURCHARGE 4 50 Paid Credited Due 46 00 00 4 50 50 50 00 00 00 00 Date 10/24/07 00 00 00 00 INSPECTION ELECTRICAL TYPE DATE. RESULTS INSPECTOR DITCH SERVICE ROUGH IN FINAL COMMENTS /0 to 0 7 AP Re Go /2�4M(. h r wrr2 a k_ Pt' sw i rte, 10-10-207 \ 6,39\ FROM ANGELES ELECTRIC INC 360 452 9265 P.l .-. , fa ~ ._/i ~_..~. ELECTRICAL WORK PERMIT APPLTCAT10~ Electrical conttllctor n;:,mc License number Date Expires ANGELES ElECTRIC, INC. ~L4 (ASI flRSl PORT ANGElE~. WA 98362 Stat.:: ZIP installation description ~ o Commercial ~Re.~ideDtial Q.New ~edJAddi(iOn Job wired by lectrical Contractor 0 Owner p\.Irchascr's m3.i1ins ll.ddn's:s ilLlkit ~ /' ,IU ~ ~~, I .~ff ,jL{~H:ti. City Telephone number FAX number kJ, ~ , City rbon~' Dumber to scbedule tnsp(~ctlon= Owner as chimed. by RCW19.18.26J:(I) Owner wiIJ occupy the strut'hm: for two yell,.s o..fkr rhi~ elec,rico/ pcrmill~~ fitJali:!.cd. (2) Owner is reqllin.1d to hire all electrical contractor if abovE.' said prQI)Cf'(V i.~ for sale. rf,:nl 'IF" Icase. After reading- the abovl; Slatt::ment. l -hereby cenify that 1 ilIJ11hc OWl'CT {)f tne above. .lamed property or a licensed elcctrical contrJ.ctor. 1 am Olakitlg The elcclrical in::>loll- lation or altcr,\liol.l ;1\ c()l\\pliancc wilh tlle: cleetl'ica.l laws, N .E.C.. RCW, Chi1ptcf 19.2R, WAC. Chapter 296-J6R. Thc City of Porl Angeles Municipal Code. and Utility Spt:cificaliolls. SigD::Iture of T, electri o Cash 0 Check # ~ard Vi", Mastercard . Discover Card# __.___-~_-A~-____ x Expiration Date of card ~~cI SeNice a Temp Servioo [J Underground -Service Service Information Volt'ge~~ Phase CJ Service Size; {;f3 Feede( Size: ,- ~ A dltion LOAD CHANGES D Baseboard ~ KW CJ Furnace KW o Heat Pump .__ Ton -'--- LAR [J Far...Wall KW ti SAME DAY INSPECTION. CALL BEFORE 7:00 AM 360-417-4735 / ROUGH-IN 1lIERMOSTAT "\ ,- SERVlCE AppI'OVW;\) " 0111<; - AJ'Il'>mvltdHy " Ollie Approvgod,fly UMl: "\ - ""\ ~L DITCH FEEDER /Oo..o() ~o, / . UlIle Appl'OvcoJ,Br D"-IC At'I>IOvCl'l By lnspccti()l'l Area, Building or tyuipn\ent hlSpectcd Actiol) Taken Elect,dca.l , Drttc Inspector "" -, -, ~~_..., ~= ~lQI - lfillb,II./11J;;;.O f1 OCTl,O 200 - .. - UGHT DEPT -