Loading...
HomeMy WebLinkAbout201 Orcas Ave Technical - Building TECHNICAL Permit # OJ- -~ 30 / :tJ (J (0 - L( q~ I Address ~r.oo~ P}"htltf-. Project description Date the permit was finaled tv It ~ /01- f . Number of technical pages & IntelliKnight@ Model 5700 :~'j Single Loop Addressable ,:'~1).~:-~'.!; Fire Alarm Control System ,': "'.~ , The affordable addressable fire alarm control panel solution. IntelllKnlght Model 5700 IS a 50 pOint class leading single loop addressable fire alarm control/communicator system 5700 provides you with the revolutionary value and performance of addressable sensing technology combined with exclusive, bUilt-in digital communication, dlstnbuted Intelligent power, that Includes an easy to use interface. Powerful features such as dnft compensation and maintenance alert are delivered in this powerful FACP from Silent Knight. For more Information about the IntelllKnlght system, or to locate your nearest source, please call 1-800-446-6444, or In Minnesota, call 763-493-6435 Description 5700 performs dnft compensation and calibration checks on each of the sensors In the system. The baSIC IntelliKnlght 5700 system can be enhanced by adding modules such as 5860 remote annunciator, 5824 senal/parallel pnnter Interface module (for pnntlng system reports), and 5496 Intelligent power module 5700 also features a powerful bUlIl-in dual line fire communicator that allows for reporting of all system activity to a remote monltonng location Features Up to 50 addressable pOints Up to 125 zones and 125 output groups Uses standard wire-no shielded or tWisted pair required BUIIt-m digital communicator Central station reporting by pOint or by zone Supports Class B (Style 4) and Class A (Style 6 or 7) configuration for SLC Dlstnbuted, Intelligent power Dnft compensalton 13 pre-programmed output cadences (Including ANSI-3 41 ) and 4 programmable outputs Notification CirCUits configurable as 1 Class A (Style Z) or 2 Class B (Style V), or aUXIliary power for resettable, constant, or door holder power BUilt-In synchrOnization for AMSECO, GentexG>, Faraday, System Senso~ and Wheelock@ appliances BUlIl-in annunciator with 80-character LCD display RS-485 bus proVides communication to system accessones . Upload or download programming, event histOry, or detector status onslte or from a remote location uSing a PC and 5660 Silent Knight Software SUite (SKSS) . Improvements In SKSS deltver five limes faster upload/downloads . BUilt-in RS-232 Interface for programming via PC . BUIIl-in Form C trouble relay rated at 2.5A at 27.4 VDC . Two bUllt-m Form C programmable relays rated at 2.5A at 27.4 VDC . Programmable date setting for Daylight Saving Time Electrical Specifications Pnmary AC 120 VAC, 60 Hz, 1.5A Total Accessory Load. 2 5A @ 27.4 VDC Notification Power' 2 5A @ 274 VDC, power-limited Standby Current. 200 mA Alarm Current: 325 mA Nolificalion/Aux Power CirCUits. 2.5A @ 27.4 VDC per CIrCUit, power-limited Battery Charging Capacity. 7 0-35 0 AH Battery Size 7 AH max allowed In FACP cabinet Larger capacity battenes can be housed In an RBB accessory cabinet Mechanical Specifications DimenSions 1275" W X 152" H x 34" 0 (32.39 W x 3842 H x 8.57 0 cm) Welgnt. 11.5 Ibs. (5.2 kg) Color Red Model 5700 Telephone ReqUirements: FCC Part 15 and Part 68 approved Type of Jack' RJ31X (two required) Approvals NFPA13, NFPA15,NFPA16,NFPA 70, & NFPA 72: Central Station, Remote Slgnalltng; Local Proteclive Signalling Systems, AUXiliary Protected Premises Unit; & Water Deluge Releasing Service. SUitable for automatic, manual, waterflow, spnnkler supervisory (DACT non-coded) slgnallmg services. Other Approvals: UL Listed, CSFM 7170-0559: 144, MEA 429-92-E Vol. XVI. SfL[NT K~l(;HT b~! Hi"- .1f:Y-.c'\el: SLC Detectors S0505-APS Addressable photoelectnc smoke detector SD505-AIS Addressable Ionization smoke detector S0505-AHS Absolure temperature heat detector that goes Into alarm Immediately If the temperature exceeds the programmable tnp pOint Tnp pOint range from 1350F-150oF (GoC-370C) SD505-6AB SIX Inch base for use with detector heads SD505-APS, SD505-AIS and SD505-AHS SD505-4AB Four Inch base for use with detector heads SD505-APS, SD505-AIS, and SD505-AHS S0505-6S8 SIx-Inch sounder base for use with eXisting sensor and base Operates In single and multi-station modes and/or as a system sounder Requires 2 additional wires for power S0505-61B Short CIrcuit Isolator base for SD5G5-AHS, SD505-APS, and SD505-AIS detectors S0505-6RB SIx-Inch relay base for use with eXisting sensor and base Provides one Form C contact SD505-ADH Ducr housing that detects smoke In HVAC ducts SD505-AOHR Duct detector base With relay Provides Form C alarm contact For use With SD505-APS and SD505-AIS sensors Compatible With SD505-DTS remote test sWitch S 0500-PS/S0500-PSOA SD500-PS IS a Single action pull station and SD500-PSDA IS a dual action pull station SLC Modules Model S0500-AIM Dry contact Input module for use With normally open dry contacts It features an Indicator LED to show alarm status S0500-MIM Mlm dry contact Input module IS a small version of the SD500-AIM For use With pull stations and other normally open dry contact Inputs S0500-ANM Addressable notification module proViding a Single Class A or Class B notification Circuit on the SLC S0500-ARM Addressable relay module that features two Form C output relays Provides indicator LED to show output status S0500-S0M TWO-Wire detector Input module Allows for the connection of conventional 2-wlre detectors on the SLC loop ReqUires two additional wires for power S0500-L1M A short ClfcUlt Isolator module for SLC deVices When a short occurs on the SLC loop, It IS detected as a trouble, but all SLC deVices protected by the Isolator module continue to operate S0500-LEO An LED dnver capable of dnvlng 80 LEOs through the SLC loop Up to 40 SD500-LEDs can be used per system S-BUS Accessories ---- 5860/R Remote Fire AnnunCIator Features the same 80 character backlit LCD display keypad and firefighter's key SWitch as the 5700 The system can be fully programmed and operated from any 5860 5860 IS gray and 5860R IS red 5496 Intelligent Power Module A 6 amp notlfl<',3tlon power expander that prOVides four additional power-limited notification appliance CirCUit outputs 5880 LEDIIO Module Features 40 LED outputs, 8 normally open dry contact Inputs and one plezo output ;rn:.:;.~.~~.<~.,\. ';: N .1;".1.""'.1 .!'UN ./'..: ~~: .::- ~i': ~. ~;.~~~;~~ ~ ; ~>,'. 5865-3 and 5865-4 Remote LED Annunciator Features 30 Programmable LED (15 red and 15 yellow) outputs and a plezo sounder The 5865-4 adds a silence and reset SWitch to the package 5883 Relay Board Features 10 general purpose Form C relays Used With 5880 module 5824 Serial/Parallel Printer Interface Module ProVides one parallel and one RS-232 senal port for connecting a pnnter to 5808 Use to pnnt a real-time log of system events, detector status reports, and event history Interfaces With bUilding control system Miscellaneous Accessories 5660 Silent Knight Software Suite User-friendly Windows software for remote programming of 5700s uSing a PC Upload and view panel account information, event history, and detector status 5670 Silent Knight Software SUite End-user faCIlity management software allows viewing of detector status and event history via modem or direct connection RBB Remote Battery Box Accessory Cabinet Use If backup battenes are too large to fit Into FACP cabinet DimenSions 16" W X 10" H X 6" 0 (406 mm W X 254 mm H X 152 mm D) S0505-0TS Remote test SWitch that proVides remote key operated test function and annunciation of detector alarm With S0505-ADHR l~." ~... ....~, -<\ ~~ ....~ ..:: :.,J :.......... w ~ tJ ~ ~::>... .. ./'-,U..;I'.N" N I. ~ , l.,~~~> '>w 5700 /. ~, ..~ "" , " ~ . >'11 .. ..~.,~) tD 5496 ThiS document IS not Intended to be used for installation purposes We try to keep our product IfIfOrmatlon up-to-date and accurate We cannot cover all speCific applicalions or anticipate all reqUirements All speclficalions are subject to change Without notice For more Informalion, contact Silent Knight 7550 Mendlan Circle SUite 100, Maple Grove, Mn 55369-4927 Phone (800) 328-0103, Fax (763) 493-6475 IntelliKmght & JumpStart are Registered Trademarks of Silent Knight Flexput IS a Trademark of Silent Knight SILENT Kl\;lCH l l:}" Ho ~t}l'...{::;l: MADE IN AMERICA FORM# 350392 Rev 0,04/06 Copynght @ 2006 Silent Knight _, INTELLlKN1GHT FIRE ALARM CONTROL PANEl '.::;:i~ 'J~~.1 IntelliKnight@ Model 5700 Single Loop Addressable Fire Alarm Control System The affordable addressable fire alarm control parlel solution. IntelliKnight Model 5700 is a 50 point class leading single loop addressable fire alarm control/communicator system. 5700 provides you with the revolutionary value and performance of addressable sensing technology combined with exclusive, built-in digital communication, distributed intelligent power, that includes an easy to use interface. Powerful features such as drift compensation and maintenance alert are delivered in this powerful FACP from Silent Knight. For more information about the IntelliKnight system, or to locate your nearest source, please call 1-800-446-6444, or in Minnesota, call 763-493-6435 Description 5700 performs dnft compensation and calibration checks on each of the sensors in the system. The baSIC IntelllKnlght 5700 system can be enhanced by adding modules such as 5860 remote annunciator, 5824 senallparallel printer Interface module (for pnntlng system reports), and 5496 Intelligent power module. 5700 also features a powerful bUilt-in dual line fire communicator that allows for reporting of all system activity to a remote mOnitoring locabon. Features . Up to 50 addressable points . Up to 125 zones and 125 output groups . Uses standard wire-no shielded or twisted pair required . Built-In digital communicator. . Central station reporting by pOint or by zone . Supports Class B (Style 4) and Class A (Style 6 or 7) configuration for SLC . Distributed, intelligent power . Drift compensation . 13 pre-programmed output cadences (including ANSI-3.41 ) and 4 programmable outputs . Notlficabon CircUits configurable as 1 Class A (Style Z) or 2 Class B (Style Y), or aUXIliary power for resettable, constant, or door holder power . BUilt-In synchronization for AMSECO, Gentex<B>, Faraday, System Sensor@ and Wheeloc!<@ appliances . BUilt-in annunciator With 80-character LCD display . RS-485 bus prOVides commumcatlon to system accessories . Upload or download programming, event hiStOry, or detector status onsite or from a remote location using a PC and 5660 Silent Knight Software Suite (SKSS) . Improvements in SKSS deliver five times faster upload/downloads . BUilt-in RS-232 interface for programming via PC . BUilt-In Form C trouble relay rated at 2.5A at 27.4 VDC . Two bUilt-In Form C programmable relays rated at 2.5A at 27.4 VDC . Programmable date setting for Daylight Saving Time Electrical Specifications Primary AC: 120 VAC, 60 Hz, 1.5A Total Accessory Load: 2.5A@ 27.4 VDC Notification Power: 2.5A @ 27.4 VDC, power-limited Standby Current: 200 mA Alarm Current: 325 mA Notlficatlon/Aux Power Circuits: 2.5A @ 27.4 VDC per Circuit, power-limited Battery Charging Capacity: 7.0-35.0 AH Battery Size: 7 AH max. allowed In FACP cabinet. Larger capaCity battenes can be housed In an RBB accessory cabinet. Mechanical Specifications DimenSions: 12.75" W X 15.2" H X 3.4" D (32.39 W X 38.42 H X 8.57 D cm) Weight: 11.5 Ibs. (5.2 kg) Color: Red Model 5700 Telephone ReqUirements: FCC Part 15 and Part 68 approved Type of Jack: RJ31X (two required) Approvals NFPA13,NFPA15,NFPA16,NFPA 70, & NFPA 72: Central Station; Remote Signalling; Local Protecbve Signalling Systems; Auxiliary Protected Premises Umt; & Water Deluge ReleaSing Service. Suitable for automatic, manual, waterflow, spnnkler supervisory (DACT non-coded) Signalling services. Other Approvals: UL Listed; CSFM 7170-0559: 144; MEA 429-92-E Vol. XVI. SILENT KN.lGHT by Hlii1<:y'M;' I':lTEL,L1KNIGHT FIRE ALARM CONTROl PANEL . SLC Detectors SD505-APS Addressable photoelectnc smoke detector SD505-AIS Addressable 10nlzabon smoke detector SD505-AHS Absolute temperature heat detector that goes Into alarm Immediately If the temperature exceeds the programmable trip point Tnp pOint range from 1350F-150oF (OOC-37"C) SD505-6AB SIX Inch base for use with detector heads SD505-APS, SD50S-AIS and SD50S-AHS SD505-4AB Four Inch base for use with detector heads SD505-APS, SD505-AIS, and SD50S-AHS. S0505-6SB SIx-Inch sounder base for use WIth eXlsllng sensor and base Operates In single and multi-station modes and/or as a system sounder Requires 2 addlllonal WIres for power SD505-61B Short circUlt Isolator base for SD50S-AHS, SD505-APS, and SD50S-AIS detectors SD505-6RB SIx-Inch relay base for use with existing sensor and base ProVides one Form C contact SD505-ADH Duct hOUSing that detects smoke in HVAC ducts SD505-ADHR Duct detector base With relay. Provides Form C alarm contact. For use With SD505-APS and SD50S-AIS sensors Compatible with SD505-DTS remote test SWitch SD500-PS/SD500-PSDA SD500-PS IS a single action pull stallon and SD500-PSDA IS a dual acbon pull station SLC Modules Model SDSOO-AIM Dry contact mput module for use with normally open dry contacts It features an indicator LED to show alarm status SD500-MIM Mml dry contact Input module IS a small version of the SD500-AIM For use With pull stations and other normally open dry contact mputs. SD500-ANM Addressable notificallon module proViding a Single Class A or Class B nollficallon CIrcUIt on the SLC SD500-ARM Addressable relay module that features two Form C output relays ProVides mdlcator LED to show output status. SD500-SDM Two-wire detector mput module Allows for the connection of convenllonal 2-wlre detectors on the SLC loop Requires two additional WIres for power SD500-L1M A short CirCUit isolator module for SLC deVices. When a short occurs on the SLC loop, It IS detected as a trouble, but all SLC deVICes protected by the Isolator module conbnue to operate SD500-LED An LED dnver capable of driVing 80 LEOs through the SLC loop. Up to 40 SD5oo-LEDs can be used per system S-BUS Accessories 5860/R Remote Fire Annunciator Features the same 80 character backlit LCD display keypad and firefighter's key SWitch as the 5700 The system can be fully programmed and operated from any 5860. 5860 IS gray and 5860R IS red 5496 Intelligent Power Module A 6 amp notlficallon power expander that prOVides four additional power-limited nollfication appliance CircUit outputs 5880 LEDIIO Module Features 40 LED outputs, 8 normally open dry contact inputs and one plezo output 5865-3 and 5865-4 Remote LED Annunciator Features 30 Programmable LED (15 red and 15 yellow) outputs and a plezo sounder The 5865-4 adds a Silence and reset SWitch to the package 5883 Relay Board Features 10 general purpose Form C relays Used with 5880 module 5824 Serial/Parallel Printer Interface Module ProVides one parallel and one RS-232 serial port for connecting a printer to 5808. Use to print a real-lime log of system events, detector status reports, and event history Interfaces With buildmg control system Miscellaneous Accessories 5660 Silent Knight Software Suite User-friendly Wmdows software for remote programming of 5700s uSing a PC Upload and view panel account mformallon, event hiStory, and detector status 5670 Silent Knight Software Suite End-user facility management software allows vlewmg of detector status and event history via modem or direct connection. RBB Remote Battery Box Accessory Cab met Use If backup battenes are too large to fit mto FACP cabinet DimenSions 16" W x 10" H x 6" 0 (406 mm W x 254 mm H x 152 mm D) SD505-DTS Remote test SWitch that prOVides remote key operated test function and annunciation of detector alarm with SD505-ADHR .~.... """- ...~.S>>.~~ :-......-.::.~..., ::<:->>:,I'.&,. ~~~....~~ ...:........."" /,.r. "'(J' t ~~~~ ..~. ~~: :-~~<...'ty.~ ..r-~::~ ...~~;:.~.. ""'" '$.;r.,~.y:v ,:.,h.OVj.<.Co..<( ..Yo >. .. -I- ........:.w ~:~..:.~~:~~~ ',,; <:.,:..~~~::~..>> (": ; :,,1 '" -j ~;:'l . .. ',' N ~ .... . ,,' . ............... ., ;:.. ~ t' , < :t...~ ;~ .~~J.#~~ . ~;:.:-::-:..~:.:.:. ~.' ;;I 5700 '-41 . ~:::-::-:-~::::.;~;.>.. 5496 ThiS document IS not Intended to be used for installabon purposes. We try to keep our product Informallon up-to-date and accurate We cannot cover all speCIfic applicallons or anticipate all requirements. All speclficallons are subject to change Without nobce For more Information, contact Silent Knight 7550 Meridian Circle SUite 100, Maple Grove, Mn 55369-4927 Phone' (800) 328-0103, Fax: (763) 493-6475 IntelllKnight & JumpStart are Registered Trademarks of Silent Knight Flexput IS a Trademark of Silent Knight m SILENT ~ l(~f(;ll<r by HO:1t'J';'Well MADE IN AMERICA FORM# 350392 Rev 0,04/06 Copynght @ 2006 Silent Knight ........... ,......~ '..:- .... :'.: .... ........~ . . . .. .... .... . .. .......... . .... ." 'n."" " , .. ..... '.- : UN u, , '. ..... ....... .... '::. . .... . . .. '.::::.' :'. :.......... ....:.. .'. .".~:::::. :.... .... . .......:.: ..:,,:.:':,,::'.-; .:.. : ............... . .' ........ . U ICIIJ .~ 6. loac..l.Hl IU..!. UlUtl aanFll'llM ~~.l ~ ___ Commander3 Series Selectable Candela Evacuation Signals Applications The Commander3 Series is a low profile strobe or horn/strobe combination that otters dependable audible and visual alarms and the lowest current available. The GE3 Senes 24VDC offers tamperproot field seleclable candela options of 15,30,60,75. and 110 candela. The 12VDC oHers tamperproof field selectable can~ieja options of 15, 30, 60, and 75 candela. The Commander3 Set las horn offers a continuous or synchable temporal three In 2400Hz and mechanical tone, a chime and whoop tone. All tones are easy for the professional to cnange in the field by uSing SWitches. The GE3 Senes has a minimal operation current and has a minimum flash rate or 1 Hz regardless of Input voltage. The Cornrnand8r3 Senes IS stllpped Wltt1 the standard 4" mounting platE: WhiCh II:corpOrates ihe popular Super-Slide'" feature that allows the Installer to easily test for supervision. The product also features a locking mechanism which secures the product to the bracket without any screws shOWing. The Commander3 also features the Checkmate'. - Instant Voltage Venflcatlon feature WhiCh allows the Installer to check the voltage drop draw and match It to the bluepnnt. The GE3 Senes appliances are UL 464 and UL 1971, listed for use with fire pro- tectl'/8 systems and are warranted for three years from date of purchase. Standard Features · Nomlllal Voltage 12 & 24 VDC · 24 VDC: units have tl81d selectable candela options 01 15, 30. 60, 75, and i 1 0 candela .. 12 VDC units ilave field selectable candela options of is, 30, 60, and 75 candela · GEH ~lorn IS available in 12 or 24 Volt · Super-Slide'" Bracket - Ease of SupervIsion Testing · Checkmate'~ - Instant Voltage Verification · Unit Dimensions: 5" high x 4.5" Wide x 2.5" deep .. Synchrorllze Strobe and/or Horn wltt1 Gentex Senes Control Module (12 Volt product must use the AVSM Module) · Prewlre Entire System, Then Install Your Signals .. Lower instaliatlon and Operating Custs · Input Terminals 12 tv 18 AWG · SWitch SelEJctlon fOI Hlgj-1 or Low dBA · SWitch for Chime, Whoop, Mechanical and 2400Hz Tone .. Tamperproof Re-entrant Grill GEC3/GES3 12 & 24 VDC SERIES .... . .... ................ ..~ . >>:-..... ~....::.......~ '.,~ *~ "~,, ~""';t;~~ ~ "'S "~ ." ~.~q f.:~?:~ ~~'~t~:{;~: ..:..~w, {~'~ ~Z~n'; · ~' *~, ,"~.,~..{..~ ~~, .{'.' ""~<'~:;< .~~..",/:', . ~%r: 'l>Sl'~ " '.~~~. f':.i;;,~ .~ , :llW: , lll'1 Product Listings ..'>'^ ~ '{~;..,\"~,,, "'y.'~ ,,~-' "\. \ ~...1,':;;{.,"""1 ~~.~'ty ( eliii' US f M ~f?jt;~::, \:Y M>f>RCVE)) ^ " ................ ).."..~ I . .....l '," ,} ...'( .~....< 1')(.... I : . l:x.h >, (.....l':<}'...h'....t-:.~.~~....j.,;.k.... N . BFP (City of Chicago) · BS+A1MEA #28S-91-E · CSFM 7135'{)S69:122 (GEC3-24 & GEH-24) 712S-0569:123 (GES3-24) 7125-0569:129 (GES3-12) 7135-0569:130 (GEC3-12 & GEH-12) . FM Approved . UL 464 & UL 1971 Listed . CANlULC S526-M87 Listed ULSZ7.S3406 Listed (GECa-24, GEI-124 & GEH12) Product Compliance . NFPA 72 . Americans with Disabilities Act (ADA) <<.=r<$~ ~ NEAM '. ~ MliMBfiR I!~'-Hu.(: ~.N .,{(....., d SWitch for Continuous or Temporal 3 (not available on whoop tone) · Surface Mount With the GSB (Gentex Surface Mount Box) " S:lence Hom Whiie Strobes Remain FlashmrJ " Wide Voltage Range 8-17.5 VDC (12 Volt Models) 16-33 VDC or FWR (24 Volt Models) .. Faceplate Available In Red or Off-White GEH 12 or 24 Volt Low Profile Evacuation Horn GES3 12 or 24 Volt Selectable Candela Low Profile Evacuation Strobe art Model desl9nations: "W" = Wall Mount "R" = Red Faceplate "W" = Off-White Faceplate "P" = Plain (no lettenng) Available with all models. These units are non-returnable "Agent" bezel also available. (I - GEC3 12 or 24 Volt Selectable Candela Low Profile Evacuation Horn/Strobe art Notes: . The GE3 Series IS not listed for outdoor use. · Operating temperature. 320to 1200F (00 to 490 C). . For nominal and peak current across UL regulated voltage range for filtered DC power and unfiltered (FWR [Full Wave Rectified]) power, see Installation manual. 12 volt models are DC only . Gentex does not recommend using a coded or pulsing signaling circuit with any of our strobe products (see Technical Bulletin Number 014). ro uct tro e urrent oop 'Operaling the horn In thiS mode at this voltage Will resu~ In not meeling the minimum Ul reverberant sound level required for publiC mode fire protection service These set- lings are acceptable only for pnvate mode fire alarm use Use the high dBA selling for public mode applical10n (not applicable when uSing the chime tone The chime tone IS always pnvate mode) Notes: The sound output for the temporal 3 tone IS rated lower since the I1me the horn IS off IS averaged Into the sound output rating While the horn IS prodUCing a tone In the temporal 3 mode ItS sound pressure IS the same as the continuous mode To obtain the horn/strobe current draw, add the strobe current draw and the horn current draw. 1 The listed reverberant dBA are for the Continuous Tone mode The Temporal 3 Tone has a reverberant dBA @ 10ft per Ul464 IS 77-83 With a horn current draw of 34mA. 2 RMS current ratings are per UL average RMS method UL max current rating IS the maximum RMS current wrthln the listed voltage range (16-33VDC for 24VDC Units) (B-17VDC for 12VDC Units) For strobes the UL max current IS usually at the minimum listed voltage (16VDC for 24VDC unITs) (BVDC for 12VDC units) For audibles the max current IS usually at the maximum listed vollage For unfiltered FWR ratings, see installation manual