Loading...
HomeMy WebLinkAbout817 Madeline St Technical - Buildingr JV3JXJJ3tL 2003 IBC LATERAL ANALYSIS ONLY FOR. REALITY HOMES PLAN. MACARTY2262 SITE CRITERIA SINGLE USE ONLY THIS ENGINEERING IS SITE SPECIFIC DO NOT ACCEPT WITHOUT AN ORIGINAL RED SEAL Copyright 2006 Hodge Engineering Inc. SHEET Cover 05 -16 -06 DATE GROUND WIND SNOW SPEED LOAD (MP1) 130 Per 185 MPH EXPOSURE SEISMIC SOIL DESIGN PROFILE CATEGORY SITE XXX MADELINE ST PORT ANGELES WA 98363 PLAN NUMBER MACARTY2262 2003 IBC D I D ORIGINAL STAMP MUST BE RED TO BE VALID Hodg To 2 Jo AsNW. Harbor WA Ybois. (2 3)e engineering inc Fax .(2 3) 8 RESIDENTIAL ENGINEERING REPORT 6.0576 Hodge ngineerinq inc Engineering Instructions and Notes All structural members are shown on the engineering S pages. The enclosed engineering calculations document the analysis used to determine the structural members of the S pages. The engineering calculations are not required to be referenced for construction Contractor shall verify all notes, dimensions and conditions prior to construction. Contractor shall provide temporary bracing as required until all permanent connections have been installed. Engineer and designer shall be notified by the contractor of any discrepancies at the time they are noted (IBC 2301.2) There are three methods for the design of wood based structural elements. These methods are allowable stress design (ASD) load and resistance factor design (LFRD) and conventional light frame wood construction This engineering uses allowable stress design in accordance with the provisions of Sections 2304 (General Construction Requirements) 2305 (General Design Requirements for Lateral- Force Resisting Systems) and 2306 (Allowable Stress Design) of the 2003 IBC The provisions of conventional light -frame wood construction (IBC 2308) do not apply unless noted otherwise This engineering report contains the results of the lateral engineering calculations (and gravity load if noted) for the proposed structure Lateral load modeling was completed with Wood Works Design Office (www.woodworks- software.com 800 844 -1275) Wood Works was developed based on the American Forest Paper Association s National Design Specification (NDS) for Wood Construction The AF &PA is the same professional organization that produces the Allowable Stress Design (ASD) manual for engineered wood construction National Design Specification (NDS) for wood construction Wood Frame Construction Manual (WFCM) for one -and two family dwellings and the Load and Resistance Factor Design (LFRD) manual for engineered wood construction Gravity load calculations (if completed) were accomplished on Wood Works Sizer wood database to determine member size Any member to member connections that are not common are detailed on the prints. Scone of Services: Hodge Engineering Inc. provides engineering to resist lateral loads (and gravity if noted) in accordance with the 2003 IBC This engineering is for the structure and foundation only Foundations are engineered to support the structure with an assumed 1500 psf soil bearing No soils report has been provided to Hodge Engineering Inc. unless specifically noted on the engineering S sheets. Special foundations for steeply sloped lots or with poor soil bearing are not provided unless noted otherwise It is the client's responsibility to notify the engineer about special site conditions. Gentle slopes not requiring a geotechnical report by the jurisdiction are accommodated by the step footing and pony wall details of the S sheets. Architectural Revision. The architectural plans are used as the basis for engineering The architectural plans usually do not meet all engineering criteria and require modification It is the client's responsibility to identify these changes on the engineering plans and to notify their architect and get any plan changes necessary prior to start of work. Changes may include additional foundations or footings, beam size changes, siding changes etc. Where required'by the building official the classification and investigation of the soil shall be made by a registered,.design professional.;( 1802.1) Site grading The ground immediately adjacent to the foundation shall be sloped aWay'from the building at a slope of not less than 5 percent for a minimum of 10 feet (1803.3) Compacted filimaterial shall not be used unless allowed by a soils engineering report (1803 5) Hodge Engineering, Inc. John E. Iiodge P E 2601 Jahn Ave NIA Ste. Al Gig Harbor W A 98; I N E ST (253) 57-73'61 I LES 98363 2 of 11 Hodg engineering i nc Materials Lumber shall conform to DOC PS 20 Manufactured I- Joists shall conform to ASTM 5055 Structural glued laminated timber shall conform to AITC A190 1 and ASTM D 3737 Preservative- treated wood shall conform to applicable AWPA standards Trusses, truss drawings and truss engineering shall be provided by the manufacturer Metal plate connected Wood trusses shall be manufactured as required by TPI 1 Floor and roof sheathing shall be per IBC tables of section 2304 Fastening shall be per the 2003 IBC fastening schedule table 2304 9 1 Plywood APA Rated Roof 15/32 CDX or OSB PI 24/0 Floor T &G CDX or OSB PI 48/24 Concrete Minimum specified compressive 28 strength (Table 1904.2.2(2)) Air entrainment per 1904.2.1 2,500 psi for basement walls and foundations not exposed to the weather damp proof walls below grade 2,500 psi for slabs and interior slabs on grade except garage floor slabs 3 000 psi for vertical concrete surfaces exposed to the weather 3 000 psi for driveways, curbs, walks, patios, porches, carport slabs, steps and other flatwork exposed to the weather and garage floor slabs. Reinforcina Steel ASTM A -615 Grade 40 for #4 and smaller ASTM A -615 Grade 60 for #5 and larger CODE CRITERIA Building Codes 2003 International Building Seismic Zone D Response Mod Factor 6 5 Soil Profile D Wind Zone Speed and Exposure on,engineering calculation cover and S sheets Design ASD ASCE 7 SOILS CRITERIA Soils Consultant Soils Report Bearing Pressure Bearing Depth Minimum uniformly distributed Attics with Storage Attics without Storage Decks Exterior Balconies Fire Escapes Guardrails and Handrails Guardrails in -fill Components Passenger Vehicle Garages Rooms other than.Sleeping Rooms. Sleeping Rooms' Stairs None provided by builder unless noted on S sheets If provided to Hodge Engineering report will be noted on S sheets 1500 psf assumed unless noted otherwise 12' Live Loads 20 psf 10 psf 40 psf 60 psf 40 psf 200 psf 50 psf 50 psf 40 psf 30 psf 40 psf 4.24 06 I -Iodge Engineering, Inc. John E. Bodge P E. 2601 Jahn Ave NW Ste. Al Gig Harbor WA g INE ST 857 -7f ��R LEE 98363 3 of 11 Lateral Analysis.wsw Level 1 of 2 WoodWorks® Shearwalls SOFTWARE FOR WOOD DESIGN WoodWorks ®Shearwalls 2004b May 8, 2006 15:31:37 1 C -2 r-i•"- 7 C -3 B_1 B-2 A -1 111111•116 72:5' 70' 67.5' 65' 62.5' 60' 57:5' 55' 52.5' 50' 47.5' 45' 42.5' 40' 37.5' 35' 32.5' 30' 27.5' 25' 22.5' 20' 17.5' 15' 12.5' 10' 7 5' 2.5' •0' 1 I I I 15'12.5' -1 7.5' 5' -2.5' 0' 2.5' 6' 7j5' 10'12.5'15'17.5'20'22.5'25' 275'30'32. 5'35'37.5'40' 5 55 57 5 60 62.5 65 67.5'70' 2:5' 5' 7.5' 10' 12.5' 15' XXX MADELINE ST PORT ANGELES WA 98363 4 of 11 Lateral Analysis.wsw Level 2 of 2 WoodWorks® Shearwalls SOFTWARE FOR WOOD DESIGN Wood Works® Shearwalls 2004b May 8, 2006 15:31:37 r,- I c -1 N B -1 67:5' 65' 62.5' 60' 57:5' 55' 52.5' 50' 47 5' 45' 42:5' 40' 37.5' 35' 32.5' 30' 27:5' 25' 22.5' 20' 17'5' 15' 12.5' 10' 7:5' 5' 2.5' 0 0• 2.5' 5' 7.5' 10' 12.5' 15' 17.5' 20' 22.5' 25' 27 5' 30' 32.5' 35' 37.5' 4b' 42.5' 45' 47.5' 50' 52.5' 55' XXX MADELINE ST PORT ANGELES WA 98363 5 of 11 Lateral Analysis.wsr WoodWorks® Shearwalls COMPANY AND PROJECT INFORMATION Company Hodge Engineering Inc 2601 Jahn Ave NW Suite A 1 Gig Harbor, WA 98335 DESIGN SETTINGS Design Code IBC 2003 Duration Factor 1 60 Plywood Wind Seismic 3 5 3 5 SITE INFORMATION IBC Occupancy Category II All others Wind ASCE 7 general analytic method for all bldgs Design Wind Speed Exposure Enclosure Shape Site Location: TG =100F Shearwall Relative Rigidity Hold -down Forces: Seismic Materials: 85mph Exposure B Enclosed Topographic Information [ft] Height WoodWorks® Shearwalls 2004b Dry Project Information I Protect 2262 Merriwood 2003 IBC Exposure B Siesmic Zone D Wind Capacity Increase Load Combinations Shear C &C Panels 0 70 Seismic 1 40 1 60 1 00 Wind Nail Withdrawal Modification Temperature Moisture Content Range Fabrication Service SOFTWARE FOR WOOD DESIGN Wind Standard Seismic Standard ASCE -7 ASCE -7 Dry Maximum Height -to -width Ratio Fiberboard Lumber Wind Seismic Designed capacity using flexible distribution Based on applied shearline force Ignore gypsum for exterior walls Building Code Capacity Reduction Wind Seismic 1 00 1 00 Max Shearwall Offset [ft] Plan Elevation (within story) (between stories) 4 00 3 33 Blocked May 16, 2006 13.51 10 Gypsum Unblocked ASCE -7 Equivalent Category II All others Seismic ASCE 7 equivalent lateral force procedure Use Group I Design Category D Site Profile Class D Spectral Response Acceleration Length S1 0 600g Ss:1 400g Fundamental Period E -W T Used 0 160s Approximate Ta 0 160s Maximum T 0 192s I Response Factor R 6 50 N -S 0 160s 0 160s 0 192s 6 50 XXX MADELINE ST PORT ANGELES WA 98363 6 of 11 WoodWorks® Shearwalls Structural Data STORY INFORMATION 1 1 Story Floor /Ceiling Wall Elev [ft] Depth fin] Height [ft] Ceiling 19 67 0 0 Level2 11 67 10 0 8 00 Level1 2 83 10 0 8 00 Foundation 2 00 Lateral Analysis.wsr May 16, 2006 13'51 10 BLOCK and ROOF INFORMATION Block Roof Panels Dimensions [ftg I Face Type Slope Overhang [ft] Block 1 2 Story E -W Ridge Location X,Y 0 00 22 00 North Side 30 0 1 00 Extent X,Y 52 00 29 50 South Side 30 0 1 00 Ridge Y Location, Offset 36 75 0 00 East Gable 90 0 1 00 Ridge Elevation, Height 28 18 8 52 West Gable 90 0 1 00 Block 2 1 Story N -S Ridge Location X,Y 30 25 0 25 North Joined 90 0 1 00 Extent X,Y 21 75 22 00 South Gable 90 0 1 00 Ridge X Location, Offset 41 13 0 00 East Side 30 0 1 00 Ridge Elevation, Height 17 95 6 28 West Side 30 0 1 00 XXX MADELINE ST PORT ANGELES WA 98363 7 of 11 WoodWorks® Shearwalls Lateral Analysis.wsr May 16, 2006 13.51 10 MATERIALS by WALL GROUP Wall I Sheathing [in] Fasteners Spcg [in] Framing Members [in] Apply Grp Surf Material Thick Orient I Size Type Edq Fld I Blkq Species G Spc I Notes 1 Ext SS incl OSB 7/16 Vert Bd Nail 4 8 yes Hem -Fir 0 43 16 1 3 2 Ext SS incl OSB 7/16 Vert 8d Nail 4 8 yes Hem -Fir 0 43 16 1 3 Notes. 1 Capacity has been reduced according to IBC specific gravity adjustment. 3. Shear capacity for current design has been increased to the value for 15/32' sheathing with same nailing because stud spacing is 16' max. or panel orientation is horizontal. XXX MADELINE ST PORT ANGELES WA 98363 8 of 11 WoodWorks® Shearwalls Lateral Analysis.wsr May 16, 2006 13.51 10 SHEARLINE, WALL and OPENING DIMENSIONS North -South Type Wall Location Extent [ft] Length FHS Height Shearlines Group(s) X rftl Start End rftl Eftl (ft] Line 1 Level 1 Line 1 Level 1 Seg 1 0 00 22 00 52 00 30 00 25 00 8 00 Wall 1 -1 Seg 1 0 00 22 00 52 00 30 00 25 00 Opening 1 25 75 30 75 5 00 6 75 Line 2 Level 2 Line 2 Level 2 Seg 1 14 50 22 00 52 00 30 00 30 00 8 00 Wall 2 -1 Seg 1 14 50 22 00 52 00 30 00 30 00 Level 1 Line 2 Level 1 NSW 14 50 22 00 53 00 31 00 0 00 8 00 Wall 2 -1 NSW 15 75 52 00 53 00 1 00 0 00 Line 3 Level 1 Line 3 Level 1 NSW 24 75 52 00 53 00 1 00 0 00 8 00 Wall 3 -1 NSW 24 75 52 00 53 00 1 00 0 00 Line 4 Level 1 Line 4 Level 1 Seg 1 30 00 0 00 52 00 52 00 22 00 8 00 Wall 4 -1 Seg 1 30 00 0 00 22 00 22 00 22 00 Line 5 Level 2 Line 5 Level 2 Seg 2 38 50 22 00 52 00 30 00 30 00 8 00 Wall 5 -1 Seg 2 38 50 22 00 52 00 30 00 30 00 Line 6 Level 1 Line 6 Level 1 Seg 1 52 00 0 00 52 00 52 00 49 00 8 00 Wall 6 -1 Seg 1 52 00 0 00 52 00 52 00 49 00 Opening 1 18 00 21 00 3 00 6 75 East -West Type Wall Location Extent [ft] Length FHS Height Shearlines Group(s) Y Eftl Start End rftl Eft] Eftl Line A Level 1 Line A, Level 1 Seg 1 0 00 30 00 52 00 22 00 6 00 8 00 Wall A -1 Seg 1 0 00 30 00 52 00 22 00 6 00 opening 1 33 00 49 00 16 00 6 75 Line B Level 2 Line B Level 2 Seg 1 22 00 14 50 38 50 24 00 14 00 8 00 Wall B -1 Seg 1 22 00 14 50 38 50 24 00 14 00 Opening 1 17 50 22 50 5 00 6 75 Opening 2 30 50 35 50 5 00 6 75 Level 1 Line B Level 1 Seg 1 22 00 0 00 52 00 52 00 32 50 8 00 Wall B -1 Seg 1 22 00 0 00 30 00 30 00 17 00 Opening 1 2 75 7 75 5 00 6 75 Opening 2 10 50 13 50 3 00 6 75 Opening 3 20 25 25 25 5 00 6 75 Wall B -2 Seg 1 22 00 36 50 52 00 15 50 15 50 Line C Level 2 Line C Level 2 Seg 1 52 00 14 50 38 50 24 00 16 00 8 00 Wall C -1 Seg 1 52 00 14 50 38 50 24 00 16 00 Opening 1 18 50 22 50 4 00 6 75 Opening 2 29 50 33 50 4 00 6 75 Level 1 Line C Level 1 Seg 1 52 17 0 00 52 00 52 00 26 00 8 00 Wall C -1 Seg 1 52 00 0 00 15 75 15 75 11 75 Opening 1 4 50 8 50 4 00 6 75 Wall C -3 Seg 1 52 00 24 75 52 00 27 25 14 25 Opening 1 26 75 31 75 5 00 6 75 Opening 2 41 50 47 50 6 00 6 75 Wall C -2 Seg 1 53 00 15 75 24 75 9 00 0 00 Opening 1 17 75 22 75 5 00 6 75 XXX MADELINE ST PORT ANGELES WA 98363 9 of 11 WoodWorks® Shearwalls Lateral Analysis.wsr May 16, 2006 13.51 10 Flexible Diaphragm Wind Design SHEAR RESULTS North -South W For Shear Force [pit] Allowable Shear [pH] Crit. Shearlines Gp Dir Ld. Case V [Ibs] V/L V /FHS Int Ext Co C Total V [Ibs] ResD. Line 1 Level 1 Lnl Levl 1 Both 2573 85 8 102 9 495 1 00 S 495 12369 0 21 Line 2 Level 2 Ln2 Lev2 1 Both 2277 75 9 75 9 495 1 00 S 495 14843 0 15 Line 4 Level 1 Ln4 Levl 1 S >N 5088 97 8 231 3 495 1 00 S 495 10885 0 47 1 N ->S 5009 96 3 227 7 495 1 00 S 495 10885 0 46 Line 5 Level 2 Ln5 Lev2 2 Both 2213 73 8 73 8 495 1 00 S 495 14843 0 15 Line 6 Level 1 Ln6 Levl 1 S >N 2092 40 2 42 7 495 1 00 S 495 24243 0 09 1 N ->S 2011 38 7 41 0 495 1 00 S 495 24243 0 08 East -West W For Shear Force [pH] Allowable Shear [Of] Crit. Shearlines Gp Dir Ld. Case V [Ibs] V/L V /FHS Int Ext Co C Total V Fibs] Resp. Line A Level 1 LnA, Levl 1 Both 1389 63 1 231 5 495 1 00 S 495 2969 0 47 Line B Level 2 LnB Lev2 1 Both 1207 50 3 86 2 495 1 00 S 495 6927 0 17 Level 1 LnB Levl 1 Both 3801 73 1 116 9 495 1 00 S 495 16080 0 24 Wall B -1 1 Both 1988 73 1 116 9 495 1 00 495 8411 0 24 Wall B -2 1 Both 1813 73 1 116 9 495 1 00 495 7669 0 24 Line C Level 2 LnC Lev2 1 Both 1186 49 4 74 1 495 1 00 S 495 7916 0 15 Level 1 LnC Levl 1 Both 2479 47 7 95 4 495 1 00 S 495 12864 0 19 Wall C -1 1 Both 1120 47 7 95 4 495 1 00 495 5813 0 19 Wall C -3 1 Both 1359 47 7 95 4 495 1 00 495 7050 0 19 Wall C -2 1 Both 47 7 495 1 00 495 0 0 C- Sheathing Combination. A- Add capacities; S- Strongest only X Strongest or twice weakest. XXX MADELINE ST PORT ANGELES WA 98363 10 of 11 WoodWorks® Shearwalls SEISMIC INFORMATION Mass fibs] rsa.ftl I E-W Shear [IN I E -W Ratio Rmax N S I E W liability Factor p S Vertical Earthquake Load Ev 0.2 Sds D; Sds 0 93; Ev 0.19 D Flexible Diaphragm Seismic Design Level2 36600 720 6944 6944 0 362 0 169 -0 06 -2 41 Level1 43492 2053 4556 4556 0 161 0 238 -0 74 0 14 Structure 80092 11500 11500 1 00 1 00 SHEAR RESULTS North -South W For H/W Fact. Shear Force [plf] Allowable Shear [plf] Crit. Shearlines Gp Dir Int Ext V ribs] V/L V /FHS Int Ext Co C Total V fibs] Resp. Line 1 Level 1 Lnl Levl 1 Both 1 0 94 1854 61 8 74 2 331 1 00 S 331 8752 0 22 Line 2 Level 2 Ln2 Lev2 1 Both 1 0 1 0 2467 82 2 82 2 353 1 00 S 353 10602 0 23 Line 4 Level 1 Ln4 Levl 1 Both 1 0 1 0 4212 81 0 191 4 353 1 00 S 353 7775 0 54 Line 5 Level 2 Ln5 Lev2 2 Both 1 0 1 0 2394 79 8 79 8 353 1 00 S 353 10602 0 23 Line 6 Level 1 Ln6 Levl 1 Both 1 0 1 0 1985 38 2 40 5 353 1 00 S 353 17317 0 11 East -West W For H/W Fact. Shear Force [plf] Allowable Shear [plf] Crit. Shearlines Gp Dir Int Ext V [Ibs] V/L V /FHS Int Ext Co C Total V ribs] Resp. Line A Level 1 LnA, Levl 1 Both 1 0 75 689 31 1 113 9 265 1 00 S 265 1590 0 43 Line B Level 2 LnB Lev2 1 Both 1 0 75 2465 102 7 176 1 265 1 00 S 265 4418 0 66 Level 1 LnB Levl 1 Both 1 0 69 3992 76 8 122 8 243 1 00 S 243 10878 0 51 Wall B -1 1 Both 1 0 69 2088 76 8 122 8 243 1 00 243 5400 0 51 Wall 8-2 1 Both 1 0 1 0 1904 76 8 122 8 353 1 00 353 5478 0 35 Line C Level 2 LnC Lev2 1 Both 1 0 1 0 2396 99 8 199 8 353 1 00 S 353 5659 0 42 Level 1 LnC Levl 1 Both 1 0 1 0 3375 64 9 129 8 353 1 00 S 353 9188 0 37 Wall C -1 1 Both 1 0 1 0 1525 69 9 129 8 353 1 00 353 4152 0 37 Wall C -3 1 Both 1 0 1 0 1850 64 9 129 8 353 1 00 353 5036 0 37 Wall C -2 1 Both 1 0 1 0 64 9 353 1 00 353 0 0 C- Sheathing Combination A- Add capacities; S- Strongest only X Strongest or twice weakest. Lateral Analysis.wsr May 16, 2006 13 51 10 XXX MADELINE ST PORT ANGELES WA 98363 11 of 11 Hodge engineering Inc *Company *Contact: *Hodge Engineering Proj Architect Plan *Site Address. 92 West Road Washouqhal, WA 98671 Items with are required Reality Homes, Inc. Jared Baehmer 6 388 Pelky, Howard *Phone Fax: Mobile Email Address Please complete the information below, sign this request form, and fax to Jared at 253 423 -2070 Client Request for Engineering Support 253 722 2268 Hodge use only of e ues yam. rt" Cii'ent;liifor ton '.Proiect information Description of Problem County is requiring a ground snow load of 72Ibs The roof is already done at 50 lbs. Please call the county if you have questions Terry Midland 509 427 3919 midland @co skamania.wa.us Engineering Requested (check) Plan Modification Construction Error 0) Engineering Error Other Request Via (check) g Phone Meeting n Fax ED Other I authorize the above requested work and associated charges Client Signature (ok to start Work) See Attached (check) g YES NO 2601 Jahn Ave NW Suite Al Gig Harbor WA 98335 Te1 253 -857 7055 Fax: 253 857 -7599 www.hodaeenaineerina.com