Loading...
HomeMy WebLinkAbout2127 W 12th St Technical - BuildingLO 1 JV3IXII3-LL (Customer Service (Servicio al cliente) 1- 800 -437 -0784 1000 Ternes Drive Monroe, MI 48162 Tools required (Herramientas necesarias) Hammer (Martillo) Phillips Screwdriver (Desarmador cruz) Level (Nivel) 0 Ladder (Escalera) 0 Pencil (Lapiz) 0 Tape Measure (Cinta metrica) 0 Utility Knife (Navaja) Paint Tools (Herramientas para pintar) Caulk Gun (Pistola para masillado) Hand Saw (Sierra portatil) 0 Wood Glue (Pegamento para madera) Includ (366x366 cm), .1 2'x16' (366x488;c), 12 036 6 CM, ,1 2 24 (366x732 c o a,? 305x61 InVAL!cclo 066x488 m Optional Tools (Herramientas opcionales) Electric Drill w/ #2 Phillips Tip (Taladro electrico Broca 'Phillips') Chalk Line (Linea de marcar) 0 Square (Escuadra) Nail Pouch (Bolsillo para clavos) First. Heritage Premier Series 12' Wide Gable Techo a dos :aguas 1 Check with your local building authority before erecting. Read instructions thoroughly before you begin. Building Codes Our buildings are designed to meet most local and national U.S. codes and are not meant to be used for living space. General construction drawings can be provided. Stamped certified drawings can be provided for a fee. I Call for details. Check All Parts If a part is missing, circle the part in question and call. Please note the primer color may vary on siding and trim parts. This is a factory applied primer intended for preparing your building for painting. This is NOT a finish coat. This primer color variation will not affect the look of your building once painted. Important Lumber is graded from one side, use most attractive face to the outside. In a drawing, a dotted line represents a part hidden from view (like a part under a panel). Assistance required Assistance is necessary to handle, fit, and secure some components. Squareness is very Important! Keep 90° corners and 90° perpendiculars throughout the assembly to ensure all components fit together Check foundation size Before starting on your foundation, make sure you are building the correct size foundation for your building. Always wear OSHA APPROVED safety glasses throughout assembly process Base +3 Extenders/ Extensiones 12'x24' (366x732 cm) Base +2 Extenders/ Extensiones 12'x20' (366x610 cm) We ma ufactu kits from elect stmctla grade lumbe nd ngi eered wood products Co str ctio grade lumbe product ut from tr ha many atu al cha actensti nd blemishe that may be pr nt ome of the pi s yo c n yo kit. Nato at cha acte stic nd blemishe str ctio lumbe may nclude knots tom wood gra along edge mi r cks /splits twists limited bark along edge nd pitch pockets that may ude ap. Be u ad that the ndiwdual parts have be cut nd apected to remo e many of the wood' atu al, les appealing cha cte sti pos able Thes cha acte sti and/o blemishe will not affect the str ngth, du ability, or str eta at me my of the to shed product. Gen ally, the elite trim parts selected far yo kit e graded from only ide and should be nstalled with the most attractiv ide utward. Ou limited wa r my do of the atu at charade stir nd blemishe that with struck grade lumbe products i Base +1 Extenders/ Extensiones 12'x16' (366x488 cm) Consulte la autoridad de construccion local antes de construir el edificio. Lea las instrucciones completamente antes de empezar Codigos de Construction Hemos disenado nuestros edificios a que conformen con todos los cbdigos de construccion locales y nacionales. Los edificios no estan proyectados como residencia. Se disponen planes generales de construccion. Se disponen de planes certificados por un precio. Estos l planes no garantizan la aprobacion de los autoridades ocales. Compruebe todas las piezas Si falta una pieza, indicala con un circulo y Ilamenos. Aviso' El color del imprimador puede varier en la covertura y las partes de la moldura. Este imprimador se aplica en la fabrica y es para preparar su edificio para pintar NO es una capa de pintura terminada. La variation en el color del imprimador no afectara la apariencia de su edificio al pintarlo. Importante La Madera esta elaborada en un solo lado. Use el /ado mas atractivo en el exterior Si falta una pieza, pongale un circulo y Ilamenos. En un dibujo una linea punteada representa una pieza no vista (por ejemplo, una pieza debajo de un panel) Ayuda requerido Seleccione un sitio nivelado. Sera necesario pedir ayuda para manejar unir y reforzar algunas piezas. iEs precise escuadrar el edificio! Manfenga angulos de 90° en las esquinas y los perpendiculares durante la construccion para asegurar que todas las piezas se unen correctamente. C.om rueba las dimensiones de la cimentacion Compruebe que las dimensiones de la cimentacion son las correctas para el edificio. Siempre Ileve gates de seguridad aprobadas por HA dura la construccion. I #16608 I 02/08/20071 Made in the USA Hecho en Estados Unidos Base Building /Edificios 12'x12' (366x366 cm) Fabr amo estr egwpos de made elabo ado y de producto maqu ado de made La made elabo ada producto de Arbole tie mucha ca cterlsbca Imperfec e aturale qu pueda to algu a pi s etc idas el equlpo Este impede y cterlsti puede Mehl!' udo gr sgado obr el horde ajas /gr eta pequefia to s n orte el borde y boll qu ude a Asegu ams qu hemo ortado e Inspe ado la parte ndi iduale pa a ohm! las acterish aturale men s atr ctiva po ible Estes acterlstic y/o impel afectarin la fue du abilidad la ntegndad structural del producto final. Po to ge al, las pi de moldu xte ele ada par equipo s elabor de n olo lade y deben statada la parte mAs atractiv por fue Nu stra gar ntla limitada ubr la ctertstic impete que urre to producto de made a elabo ada 0 w I 0 0 c -J N N W —J m CD J 12' x 12' (366 x 366 cm) PARTS LIST 8 "x84" 3/8 "x15- 7 /8 "x84" i 12' X 12' (366 x 366 cm) LISTA DE PIEZAS WO 1 'x4 'x72 3/8' (2.5x10x184 cm) WP x4 1 'x4'x72' (2.5x10x183 cm) x1 YD 1 'x4 'x83 -5/8' (2.5x10x212 cm) 1 'x4'x63 -1 /4 (2.5x10x161 cm) YB x4 YMX x4 HM 1 'x4 'x68-3/8' (2.5x10x174 cm) 1'x3 "x84 (2.5x10x213cm) x4 End Caps x4 T El Fin Tapa x4 3/8 "x4 (.9x122x213 cm) (.9x40x213 cm) 3/8 "x11 7/8 "x32" (9x30x82 cm) 2x6x92 1/2" (5x15x235 cm) UN UY Rafter UW x9 B 2x4x94 -1/2" (5x10x240 cm) 2x4X6 -1 /2" (5x10x17 cm) x7 7/16 "x48 "x96' (1 1x122x244cm) 3/8 "x23- 9/16 "x48' (9x61x122 cm) x2 UL 2x4x48" (5x10x61 cm) SP x2 c 2x4x92 5/8" (5x10x235 cm) Viga Gusset x14 x10 UM 7/16 "x47 7/8 "x48' (1 1x122x122cm) 3/8 "x23- 7 /8 "x84" (.9x61x213 cm) x8 TK 2x4x68' (5x10x173 cm) 3/8 "x33 -1 /2 "x48' 3/8 "x23- 9/16 "x48' (.9x85x122 cm) (9x61x122 cm) X2 D 2x4x80" (5x10x203 cm) x2W 7/16 "x32 "x96' (1 1 x81 x244cm) x2 G -1 Placa de union x27 VF 2x6x67' (5x15x171 cm) x12 KP 3/8 "x2 "x3 -11 /16' (.9x5x10cm) X2 VK 2x6x48" (5x15x122 cm) 3/8 "x5 "x33" (.9x13x84 cm) x2 F -1 1 x4x96' (153 cm) 7/16 "x31 7/8 "x48' (1 1 x81 x122cm) 2 "x4 'x19 -3/16' (5x10x49 cm) c Z x4 CaM x2 x2 x2 x5 2 2 "x4 "x68 -1 /2' (5x10x174 cm) Puerta izquierda Right Door 1 'x4'x35 -1/4 (2.5x10x91 cm) x2 WGL Puerta derecha 68 -1/2" Weatherstrip (174 cm) x1 DWS 1 'x4'x35 -1 /4 (2.5x10x91 cm) x1 DEL x2WGR x2 68 -1/2" Metal Door Edge 'L" (174 cm) 1 'x4 'x14 (2.5x10x36 cm) x4 12' X 12' (366 x 366 cm) PARTS LIST i 12' X 12' (366 x 366 cm) LISTA DE PIEZAS 1 1/4' (3cm) x2 i x2 x1 1 (2.5cm) �GG GGGGGGCGGCkCG x2 OX-C.F V-V -UV —C4-4 x2 NOTE Double and Triple letter part identification letters are stamped on parts and read horizontally single letter part designations are not stamped Lumber Sizes (Dimension nominal) 1x4 2x4 2x6 Actual Size Dimensiones verdaderas 3' (7 6 cm) 2' (5 0 cm) 2' (5 0 cm) 1 1/2' (38cm) 3' (7 6 cm) 2'(41 cm) 1 5/8' (4 1 cm) CO 1 (2.5 cm) 1 (2.5 cm) RS RS 3 F �r�'.C- �FC�C:XFG.G�FG�Gw 7rGatkGt muGLC-vgauFGECLCw4 r rGGGGGG -m-v4 G:cauG u CGGr�GCC����G x206 x695 x230 x188 GG s4. x18 x12 x10 x59 GGGGGtr_vg C -t_mx= x34 AVISO Dos letras o tres letras de identificacion estan marcadas horizontalmente en las piezas. Letras de identificacion de una sola letra no estan en las piezas. Dimensiones de la madera Dimensiones verdaderas) 3/4 x 3 -1/2' (1 9 x 8 9 cm) 1 -1/2' x3 -1/2' (3 8x8 9cm) 1-1/2' x 5-1/2' (3 8 x 14 cm) 3/8"x48"x84 3/8"x23-7/8"x84 2x6x48' 2x4x80' 2x4x48' (.9x122x214 cm) (.9x61x214 cm) (5x17x122 cm) (203 cm) (122 cm) X1 C 7/16"x32"x96' (1 1x81x244cm) 3/4 'x3-1/2"x48' (1 9x8.9x122 cm) x2 Fl Rafter VF x2 TK x4 SP 7/16"x31 7/8"x48' (1 1x81x122cnn) Viga Gusset 1x4x96' (244 cm) x2 Placa de Union 0 0 0 a 0 Ui LL 12' X 4' (366 x 122 cm) I 12' X 4' (366 x 122 cm) LISTA DE PIEZAS DE EXTENSION EXTENDER PARTS LIST Actual Size 1 1 3' (7 6 cm) 4 Dimensiones verdaderas 1 2' (5 0 cm) 1 1/2' (3.8 cm) x 214 x 12 IMPORTANT!!! IMPORTANTE!!! Building Tip Consejo FOR THE BEST LOOKING FINISHED PRODUCT WE RECOMMEND THAT YOU INSPECT, SORT AND LAY OUT MATERIALS PRIORTO BEGINNING ASSEMBLY OF YOUR BUILDING HELPFUL MATERIAL NOTICE I AVISO UTIL SOBRE LOS MATERIALES B Wood is a natural product that has inherent blemishes. All interior framing is graded for structural strength and not appearance. Exterior trim is graded for one good side per industry standards. Blemishes can be easily installed to provide the best appearance. (Fig. A) Install wall framing with any blemished sides toward the siding and facing rear of building. (Fig. B) Install corner trim, gable trim and fascia with any blemished sides toward the siding material. (Fig. C) Always install the material leaving the best edge and best surface visible. Please remember that these blemishes in no way negatively affect the strength or integrity of our product. Please feel free to call our Consumer Help Line Toll Free 1- 800-437 -0784 Monday through Friday 8:00 AM to 5:00 PM EST Saturday (March through October) 10:00 AM to 4:00 PM EST A 5 CON EL FIN DE OBTENER EL PRODUCTO ACABADO DE MEJOR ASPECTO RECOMENDAMOS QUE INSPECCIONE, CLASIFIQUEY ORGANICE LOS MATERIALES ANTES DE EMPEZAR A MONTAR SU EDIFICIO C NMI MIN La madera es un producto natural que tiene defectos inherentes. Todo la estructura interior ha sido aprobada por ofrecer una resistencia estructural y no por su aspecto. La guarnicion exterior ha sido aprobada por tener un buen lado segun las normas de la industria. La parte con defectos puede instalarse facilmente de modo que el edificio tenga el mejor aspecto. (Fig. A) Instale el entramado de la pared con los lados con defectos apuntando hacia los costados y haciendo frente a la parte trasera del edificio. (Fig. B) Instale la guarnicion de las esquinas, la guarnicion de los hastiales y las impostas con los lados con defectos apuntando hacia el material lateral. (Fig. C) Instale siempre el material dejando visibles el mejor borde y la mejor superficie. Recuerde que estos defectos no afectan de forma negativa la resistencia o la integridad de nuestros productos. Llame de forma gratuita a nuestra linea de ayuda al consumidor 1-800-437-0784 Lunes a viernes 8:00 AM a 5:00 PM, hora estandar del este Sabado (marzo a octubre) 10:00 AM a 4:00 PM, hora estandar del este FOUNDATION OPTIONS (Not supplied with kit) YOU MUST ASSEMBLE YOUR BUILDING ON A WOOD FLOOR OR CONCRETE SLAB. OPCIONES PARA LA CIMENTACION (No incluidas) HAY QUE CONSTRUIR EL EDIFICIO SOBRE UN BASE DE MADERA 0 DE CONCRETO. SITE PREPARATION Site must be properly leveled Site should have natural drainage and no standing water A) Purchase our optional Floor Kit or build your own wood floor. A) Compre nuestro equipo opcional para el suelo o construya su propio suelo de madera. Building Size Dimensiones del edificio A B 12' x 12' (366 x 366 cm) 144' (366 cm)1144' (366 cm) 12' x 16' (366 x 488 cm) 144' (366 cm)1192' (488 cm) 12' x 20' (366 x 610 cm) 144 (366 cm)1240' (610 cm) 12' x 24' (366 x 732 cm) 144' (366 cm)1288' (732 cm) Important: Square floor and level to ground before beginning assembly of building. B) Concrete Slab Foundation I B) Base en Iosa de concreto Treated Sill Soleras Inferiors Tratadas Building Size Dimensiones del edificio A B C 12' x 12' (366 x 366 cm)1144' (366 cm)1137' (348 cm)1144' (366 cm) 12' x 16' (366 x 488 cm)1144' (366 cm)1185' (470 cm)1192' (488 cm) 12' x 20' (366 x 610 cm)1144' (366 cm)1233' (592 cm)1240' (610 cm) 12' x 24' (366 x 732 cm)1144' (366 cm)1281 (714 cm)1288' (732 cm) Fasten treated 2x4 sill plates to slab using approved concrete anchors. (Treated sill plates and fasteners not included.) 6 PREPARACION DEL SITIO El sitio debe de estar nivelado correctamente. Instale una barrera contra yerbajos debajo de la estructura. Importante• Asegure que el suelo esta nivelado y escuadrado antes de construir el edificio. 4 (10 cm) Fije las soleras inferiores tratadas 2x4 a la Iosa con anclajes de concreto aprobados. (Las soleras y los anclajes no estan incluidos.) Before proceeding, determine desired door location and build door wall first. Antes de continuar determine Ia posicion de Ia puerta y construya el muro con Ia puerta primero. BUILD WALL NUMBERS SPECIFIED WALL NUMBER EQUALS PAGE NUMBER CONSTRUYA LOS NUMEROS DE LOS MUROS ESPECIFICADOS EL NUMERO DEL MURO CORRESPONDE AL NUMERO DE LA PAGINA. IMPORTANT!!! IMPORTANTE!!! Building Tip Consejo YOUR BUILDING CAN BE CONFIGURED IN A VARIETY OF WAYS. BEFORE ERECTING WALLS, REFER TO PAGE 5 TO ENSURE YOU BUILT THE RIGHT WALLS FOR YOUR BUILDING. Erecting the Walls I Construyendo los Muros Make sure all walls are built as shown below BUILD DOOR WALL FIRST 3 -1/2' (8.9 cm) 3 -1/2' (8.9 cm) Inside of Wall Interior del muro 24' 24 24' (61 cm) (61 cm) x(61 cm)~ 3 -1/2' h cm) 9 ES PRECISO ALINEAR LOS PANELES DE LOS MUROS Y DEL TECHO ANTES DE CLAVARLOS COMPLETAMENTE PARA ASEGURAR LA ESCUADRA. Asegure que se construyan los muros como en los dibujos abajo CONSTRUYA EL MURO CON PUERTA PRIMERO Flush 1 Nivelado 3 -1/2' -►I k– (8.9 cm) 2' (5 cm) Nail /Clavo 12' (30 cm) 1 (2.5 cm)- 3 -1/2' (8.9 cm) 2' (5 cm) Nail /Clavo IMPORTANT!!! I IMPORTANTE!!! Building Tip Consejo YOU MAY NEED TO RACK YOUR WALL PANELS AND ROOF PANELS TO ENSURE SQUARENESS BEFORE COMPLETELY NAILING ES PRECISO ALINEAR LOS PANELES DE LOS MUROS Y DEL TECHO ANTES DE CLAVARLOS COMPLETAMENTE PARA ASEGURAR LA ESCUADRA. Racking a Wall I Alineando un Muro Flush Nivelado A Nail Clavo Top Corner Should Be Flush La esquina superior debe estar nivelado con la estructura When building walls, always apply panel at far left first. Position panel flush with top of wall frame and nail in upper corners as shown. Rack wall square by moving lower end of wall panel right or left until panel is flush with framing along left edge and secure with one nail in each lower corner Continue nailing as instructed. Rack for Squareness Nivele para escuadrar Position panel flush with outside front edge of rafter and nail in two corners as shown. Rack panel square by moving opposite end up or down until panel is flush along peak of rafters and secure with one nail in each corner. Ensure spacing of center rafters and nail as instructed. 10 Flush Nivelado Al construir los muros, siempre fije primero el panel hasta Ia izquierda extrema. Posicione el panel nivelado con la parte superior de Ia estructura del muro y clavelo en la esquina superior como en el dibujo. Alinee nivelado el muro por mover el lado inferior a la derecha o a Ia izquierda hasta que el panel este nivelado con Ia estructura a to largo del borde izquierda. Fije con un clavo en cada esquina inferior. Racking a Roof Alineando un techo Flush Nivelado Nail Clavo B Flush with Rafter Peak Nivelado con Ia parte mas alta de las vigas Posicione los paneles nivelados con el borde delantero exterior de la viga y slave en las dos esquinas como en el dibujo. Alines escuadra el panel por mover los extremos opuestos arriba o abajo hasta que el panel este nivelado a to largo del punto mas alto de las vigas, y fijelo con un clavo en cada esquina. Compruebe el espacio de las vigas centrales y slave como indicado. HEADER UY x7 3"(7.6 cm) 64 x 28 STOP! DO NOT BUILD DOOR FRAMING AT THIS POINT USE AS A REFERENCE ONLY 9-1/2' 24 24 9-1/2' (24cm) H (61cm) (61cm) (24cm) T TT T T .1 1 T TT 1 1 TT T ,T T Q) (163cm) Header 11 80' (204cm) E x2 WALL #15 3 "(7.6 cm) x 34 M U RO #15 2"(5 cm) x 135 REPEAT FOR ALL SPLICES Overhead View f ISP x21 83" (211cm) 6' L. (15 cm) 12' (31 cm) H Flush 1 V 24" H" 24' 24" (61cm) (61cm) (61cm) I.I I.I 48" (122cm) IULx2 I I.I I.I I.I I.I A II I II III II fl II III 144' (366cm) 15 24" I— 24' 20- 1/2 (61cm) (61cm) (52cm) 92 -1/2' (235cm) ITK x7 I 140 -1/2" /(357cm) SP 11111 Id 11111 ITK x121 UY x7 83" (211cm) 1sP 1 I 48' (122cm) Flush 6' _L (15 cm) t H 9-1/2" 24" 24" 9-1/2" III IT r(24cm)I (61cm) I (61cm) I(24cm) IHEADERI ISP1 —1 16" 64" (41cm) (163cm) 1 48' (122cm) 16" (41cm) HI I I [Bs 6' _L (15 cm) 7 If —1 24' I 24' 24" 24' 24" (61cm) (61cm) (61cm) (61cm) (61cm) (61cm) (52cm) I I 48' (122cm) 1 s P 1 12' (31 cm) I I III I 48' 92-1/2' (122cm) (235cm) A i _L___ 12' 12' (31 cm) (31 cm) 24" I-20-1/2"H II I I 1 I I I I I I I I I I I III II II II II 288' (732cm) I REPEAT FOR I ALL SPLICES 284-1/2" /(723cm) H). 1110, REPEAT FOR ALL SPLICES Overhead Mew 83" (211cm) 48" 48° 1.1 48" 1.I 1.I 48" 92-1/2" (122cm) (122cm) (122cm) (122cm) (235cm) Flush 6'L. (15 cm) 12' (31 cm) I— 24" —I— 24" I 24" H 24 I 24 H 24" I 24 1 24' H— 24' 24" —I— 24' 1 20-1/2 I (61cm) (61cm) (61cm) (61cm) (61cm) (61cm) (61cm) (61cm) (61cm) (61cm) (61cm) (52cm) SP x1:11 A A A A A 288" (732cm) I III II II II II UL x2 1 ITIC x131 284-1/2" /(723cm) ERECTING WALLS See Page 9 For Building Tip!!! ERECT SOLID WALLS FIRST CON6TRUYA LOS MUROS SOLIDOS PRIMERO See Page 7-8 for wall Ver Ia pagina 7-8 para muro. ERECTING WALLS See Page 9 For Building Tip!!! See Page 7-8 for wall Ver la pagina 7-8 para muro. Level Wall and Nail Nivele la pared y clave. 3' (7.6 cm) x 12 (12'x12') (366 x 366 cm) 16 (12'x16') (366 x 488 cm) x 16 (12'x12') (366 x 366 cm) x 20 (12'x20') (366 x 610 cm) x 20 (10'x12') (366 x 488 cm) n 2"(5 cm x 24 (12'x24') (366 x 732 cm) x 24 (10'x16') (366 x 610 cm) x 28 (12'x24') (366 x 732 cm) 3' (7.6 cm) x 17 2' (5 cm) x 18 28 3" (7.6 cm) IVer Ia pagina 9 para un consejo!!! Level Wall and Brace, Do not sink nails completely Nivele la pared y refuerzala. No hinque los clavos completamente. CONSTRUYENDO LOS MUROS iVer Ia pagina 9 para un consejo!!! CONSTRUYENDO LOS MUROS ERECTING WALLS x 22 (12'x12') (366 x 366 cm) x 28 (12'x16') (366 x 488 cm) x 34 (12'x20') (366 x 610 cm) x 40 (12'x24') (366 x 732 cm) See Page 9 For Building Tip!!! See Page 7-8 for wall Ver la pagina 7-8 para muro. 17 (30 cm) ERECTING WALLS After walls are erected, make sure X to X and Y to Y measurements are the same Level Wall and Nail Nivele la pared y clave 2' (5 cm) x 22 3"(7.6 cm) 12" (30 cm) 2" (5 cm), 12" (30 cm) X 2"(5 cm) 29 x 21 (12'x12') (366 x 366 cm) x 27 (12'x16') (366 x 488 cm) x 33 (12'x20') (366 x 610 cm) x 39 (12'x24') (366 x 732 cm) IVer la pagina 9 para un consejo!!! CONSTRUYENDO LOS MUROS Despues de construir los muros, asegurese que las medidas 'X a X' y 'Y a Y' son iguales. Y 12" (30 cm) Do Not NO In Door Opening No clave en la abertura de puerta. CONSTRUYENDO LOS MUROS See Page 7-8 for wall Remove Quite Ver la pagina 7-8 para muro. (5 cm) t 17 (30 cm) DOUBLERS 12 x 12' (366 x 366 cm) TOP VIEW 148" (376 cm) TOP VIEW 148 (376 cm) 12' x 20' (366 x 610 cm) 3 "(7.6 cm) 30 12' x 16' (366 x 488 cm x 66 (12'x12') (366x366cm) x 78 (12'x16') (366x488cm) x 90 (12'x20') (366x610cm) x 102(12'x24') (366x732cm) vF TOP VIEW 148" (376 cm) I 2,241143617 x r ISP VF T VK VF VF TOP VIEW VF VK 148" DOBLADORES ISP VF End Rafter Assembly x2 Flush/ Nivelado 2' (5 cm) Nails /Clavos UW x2 Middle Rafter Assembly (See sizes below for quantity) UW x2 Red Ends Terminos rojos Glue Pegamento 1 1 1/2 "(3.8 cm) x 12 148' (376 cm) N~ N KP Qx2 31 ti Q 2 "(5 cm) 148' (376 cm) x8 Cry s�' 1 -1/2' (3.8 cm) Nails Clavos TECHO Conjunto de vigas terminals x2 Flush Nivelado Conjunto de vigas centrales (Ver las dimensiones abajo para la cantidad) Flush Nivelado Q x2 X2 COLLAR TIES ARE NOT TO BE USED FOR HANGING, STORAGE OR AS LOFT SUPPORTS MID RAFTERS NEEDED PER BUILDING SIZE 12'x12' (366 x 366 cm) x5 12'x20' (366 x 610 cm) x9 12'x16' (366 x 488 cm) x7 12'x24' (366 x 732 cm) x11 Attaching Rafters and Soffit Blocks (See below for dimensions) 12'x12' (366 x 366 cm) 12'x16' (366 x 488 cm) 12'x20' (366 x 610 cm) 12'x24' (366 x 732 cm) 3 "(7 6 cm) x42 I— 24° 24' d— 24" 24" 4- 24" -4- 24" i (61cm) (61cm) (61cm) (61cm) (61cm) (61cm) I H 24' 24' 24" H 24' I 24" -I- 24' 4 24" 4 24" H (61cm) (61cm) (61cm) (61cm) (61cm) (61cm) (61cm) (61cm) l l I— 24" 24" —I- 24" 24" —I— 24' H— 24" 24" —H 24" —I— 24" —I- 24° —I (61cm) (61cm) (61cm) (61cm) (61cm) (61cm) (61cm) (61cm) (61cm) (61cm) 1 32 Flush Nivelado 12x12 x42 12x16 x54 12x20 x66 12x24 x78 Fijando las vigas y los bloques del sofito. (Ver abajo para las dimensiones.) Flush Nivelado 3 3' (7.6 cm) x 42 Repeat step on each rafter Repetir el paso en cada viga 3' (7.6 cm) x 54 3' (7.6 cm) x 66 IH 24" ~I- 24" 4— 24' -I- 24' 24" 24" 24" 24' 4- 24" 24" 4- 24" 24" (61cm) (61cm) (61cm) (61cm) (61cm) (61cm) (61cm) (61cm) (61cm) (61cm) (61cm) (61cm) 3' (76cm) See Page 10 For Building Tip!!! F1 G F -1 F1 I GI 12'x12' (366 x 366 cm) F1 F -1 12'x16' (366 x 488 cm) G F -1 12'x20' (366 x 610 cm) Shown Indicado G G -1 F F1 G F -1 G -1 F F F1 2 "(5 cm) 12'x24' (366 x 732 cm) Shown Indicado REPEAT ROOF PANEL LAYOUT FOR BOTH SIDES OF ROOF REPEAT ROOF PANEL LAYOUT FOR BOTH SIDES OF ROOF REPEAT ROOF PANEL LAYOUT FOR BOTH SIDES OF ROOF REPEAT ROOF PANEL LAYOUT FOR BOTH SIDES OF ROOF 33 G G -1 G1 IGi I GI IVer la pagina 10 para un consejo!!! IGI F1 x80 x110 x140 x170 Gable Panels Dry fit assembly on front and back of building to determine best alignment of grooves QM DRY FIT PANELS AS SHOWN HERE BEFORE ASSEMBLING Los paneles montan segun to visto Groove Groove Groove Surco Surco Surco 1 112' (3.8 cm) R 1 1/2" (3.8 cm) x 92 6 1 -3/4' (4 4 cm) (15 L. 34 —.I L- 3 -1/2' (8.9 cm) Paneles del techo a dos agues Compruebe Ia alineacian del surco en frente y Ia parte posteriora 12x12 (366x366cm) Shown 12x16 (366x488cm) x174 WP x2 2"(5 cm) 3/4"(1.9 cm) m amtugUtp. x150 x6 WJ x2 YMX WJ x2 12x20 (366x610cm WP x2 WP x2 x186 35 12x24 (366x732cm) WJ x2 WJ x2 WJ x2 WP x2 x198 WP x2 3/8� (9cm) Top 1- 5/8 "(41 cm) x8 7/16' (1 1cm) 3/8' (9c U e Supe I DOOR PUERTA 1 36 HM W Place a center mark for door location Ponga un senal en el centro para la puerta Cut out bottom plate at door opening Leave treated sill on concrete slab if desired Corte la placa inferior en la abertura de la puerta. Deje la solera tratada en la losa de concreto si quiere A V- B [2 MVFF-CCIttCFGFFFFFF- MC-T-MttU FTFFV-' V-MV-GP- 3' (7.6 cm) x 6 w.,.. 2' (5 cm) x 8 C p CFFFFFCFFGFFGCGFw (X 2 (2.5 cm) A B B *-I 12' (30 cm) N YD i 1 i i i i HM Do not sink nails completely No hinque los clavos completamente. x4 x4 1 Flush Nivelado 2 "(5 cm) x 72 Position trim against underside Posicione la moldura contra la parte inferior H` YD 37 J Attach with 3' (7.6 cm) Screws first, check doors to open properly and nail Fije con tomillos de 3' (7.6 cm) primero, compruebe que las puertas abren bien y clave. Inside Building Interior del edificio X A1� PUERTA Remove after doors are screwed Quite despues de fijar la puerta con tornillos. YD YD M x 4 WGR x2 WGL x 2 Plain contemporary Double X Diamond Traditional X 1"(2.5 cm) r x24 38 Outer Diamond Inner Diamond WO Existing Door Puerta Existepte UP x2 Inside View Vision Interior 1 '(2.5 cm) x 23 Exterior Trim Exterior Moldura ti UPx2 Top View: Attaching Door Stiffiner Vision De arriba: Atadura del apoyo de la puerta T �2 screw Outside Al afire libre Inside Dentro 39 1 2 "(5 cm) x 20 2 "(2.5 cm) 12 Center vertically on Door Centro verticalmente en puert: a DEL NOTE Install hook and eye into trim or stud 0 x2 1"(2.5 cm) x 34 Flush Nivelado 40 S DWS DEL HOOK AND EYE AND BARREL BOLT x2 Drill hole 1/2' (1.3 cm) deep using 3/8" (.95 cm) bit Inside of Door/ Interior de la puerta 1314' (4, 501 35 1 (89cn 1 12 ('1 2crn) 41 I PAINT AND CAULK PINTURAY MASILLADO (Not Included) (No Incluidas) Use Acrylic Latex Caulk that is paintable. Caulk at all horizontal and vertical seams, between the Trim and Walls, and all around the Door Trim. Use a high quality exterior acrylic latex paint. When painting your building, there are a few key areas that can be easily overlooked that must be painted: Bottom edge of all siding and trim Inside of doors and all 4 edges Note: Prime all un -primed exterior wood before painting Building Size Building Paint Trim Paint 'Jimensiones del edificio Pintura del edificioPintura de moldura 12' x 12' (366 x 366 cm)I 12' x 16' (366 x 488 cm)I 12' x 20' (366 x 610 cm){ 12' x 24' (366 x 732 cm)I DRIP EDGE (Not Included) GOTERO DE BORDE (No Incluidas) Close up of drip edge Vista del gotero Building Size Drip edge Dimensiones del edificio Gotero de borde 12' x 12' (366 x 366 cm) 12' x 16' (366 x 488 cm) I 12' x 20' (366 x 610 cm) I 12' x 24' (366 x 732 cm) I 2 1/2 Gallons/ aalones 3 Gallons/ aalones 3 -1/2 Gallons/ galones 4 Gallons/ galones 60 feet/pies 70 feet /pies 70 feet/pies 80 feet/pies 1Quart/cuartas I 1 Quart/cuartas 1 Quart/cuartas 1 Quart/cuartas Side that hangs over side No Nails La parte que esta colgada sobre un lado No clavar Caulk Masillado 3 Tubes/Tubos 3 Tubes/Tubos 4 Tubes/Tubos 4 Tubes/Tubos 42 Use un masillado acrilico de latex que se puede pintar Masille todas las junturas horizontales y verticales, entre Ia moldura y los muros, y alrededor de la moldura de la puerta. Use una pintura acrilica de latex de alta calidad. Al pintar su edificio hay unas areas claves que hay que pintar El borde inferior de toda Ia covertura y Ia moldura. El interior de la puerta y todos los 4 bordes de esta. Aviso Ponga un imprimador en la madera exterior que no to tiene antes de pintar Snip bottom side of drip edge and Bend over to other side of Roof Corte la parte inferior del gotero y dbblela sobre el otro lado del techo SHINGLES (Not Included) Building Size Shingles Needed Dimensiones del edificio Teias Necesarias 12' x 12' (366 x 366 cm)I 6 Bundles /bultos 12' x 16' (366 x 488 cm)I 8 Bundles /bultos 12' x 20' (366 x 610 cm)I10 Bundles /bultos 12' x 24' (366 x 732 cm)I12 Bundles /bultos Install first row backwards lnstale la primera fila al reves Line up notch on top of Shingle with edge of Roof to stagger the Shingles Alinee el corte encima de la teja con el borde del techo para escalonar las tejas. Maintain same dimension across Mantenga la misma dimension de un lado al otro Flush to edge, stagger each row Nivele al borde, escalone cada fila Remove overhanging shingles Quite tejas sobresalientes Flush to dripedge Nivelado al gotero d -e d 43 NAILS clavos I I 1 I 11 1 1 I I I I sO I I r i Okay if Shingle Overlaps Este bien si la teja sobresale I I I F I I I 1 1 MI i 111111111111111111 I -I MI a SHINGLES (Not Included) TEJAS (No Incluidas) Ridge Cap Cut Shingles into 3 pieces Corte las tejas en tres partes Apply pieces to ridge as shown Fije las piezas a la cumbrera como en el dibujo Check for protruding nails, pound any protruding nails into the wood or cut them off flush. Inspeccione para clavos sobresalientes; hinque clavos sobresalientes en Ia madera or cortelos nivelados con Ia madera. To 44 •s ft Tapa de cumbrera s 0 NAIL INSPECTION INSPECCION DE CLAVOS REQUIRED MAINTENANCE MANTENIMENTO NECESARIO Keep grass trimmed and away from building Corte y quite la hierba cerca del edificio Keep Sprinklers away from building No use rociadores cerca del edificio Repaint building as needed and in accordance with paint manufacturer requirements Pinte el edificio de nuevo cada dos anos