Loading...
HomeMy WebLinkAbout801 E Front St Technical - BuildingTECHNICAL Permit aG 70() Address s El Frohft" St Project description Nei Co rnrylerGal rEJ Jt cer er Date the permit was finaled -2 'o7 Number of technical pages lZ 02/08/07 12 37 FAX 3606812086 782 KITCHEN DICK ROAD SEQU /M, WA 98382 PHONE 360 681 -3333 FAX: 360 681 2086 Fax e Cooper MV To: Jim City of PA Bldg Dept From: Chris Hahn Estimator Fax: 417 -4711 Dote: February 8, 2007 Phone: 417 -4816 Pages: 11 Re: Cooper Bldg CC: Urgent For Review Please Comment Please Reply Please Recycle •Comments: Hi Jim, Here are the balance of the commercial heat load talcs for the Cooper Building. Spaces 1, 7 and 5 have 2# tern emits, and spaces 3 and 4 have 2 ton units, and all hails have economizers an t# n. Let me beow as stoat as passible if there's anything else you need. .541as Chris Peninsula Heat col Peninsula Heat FlOE 02/08/07 12 37 FAX 3606812086 Peninsula Heat a02 Page 1 Report Prepared By Peninsula Heat, Inc. For Copper Bldg Space #1 [Copy 21 Port Angeles, WA 98362 HVAC -Calc Commercial 4.0 by HVAC Computer Systems Ltd. Loan calculations am swims :lies only actual loads may very due to weather and conelf bon differences. Design Conditions. Port Angeles, Latitude. 47 Time 1 00 PM Indoor Outdoor Summer temperature. 75 Summer temperature: 77 Winter temperature: 70 Winter temperature: 28 Relative humidity' 50 Summer grains of moisture: 60 Daily temperature range: 16 Building Component Sensible Latent Total Total Galn Gain Heat Gain Heat Loss (BTUH) (BTUH) (BTUH) (BTUH) Floors 0 0 0 1 358 Walls 92 0 92 1,634 Windows 3,712 0 3,712 1,865 Doors 1 102 0 1 102 538_ Door Leakage _0__ 0 0 11 411 Partitions 0 0 0 0 Ceilings 1 001 0 1 001 1 809 Skylights 0 0 0 0 Duct _0__ 0 0 0 People _2,500_ 2,000 4 500 0 Ventilation 0 0 0 9,240 Infiltration 0 _0 0 2,985 Lights 3,936 0 3,936 0 Miscellaneous 0 0 0 0 Whole Budding All Components 12,343 2,000 14,343 30,640 (1 tons C tI Commercial Heat Loss and Hge Gain Calculation 2/5/2007 888 736 -1101 02/08/07 12 37 FAX 3606812086 Page 1 Report Prepared By: For Building Component Peninsula Heat E 03 Commercial Heat Loss and Heat Gain Calculation Peninsula Heat, Inc. Copper Bldg Space #1 [Copy 2] Port Angeles, WA 98362 Design Conditions: Port Angeles; Latitude: 47' Time 1:00 PM Indoor Outdoor Summer temperature: 75 Summer temperature: 77 Winter temperature: 70 Winter temperature; 28 Relative humidity 50 Summer grains of moisture: 60 Daily temperature range: 16 Sensible Latent Total Total Gain Gain Heat Gain Heat Loss (BTUH) (BTUH) (BTUH) (BTUH) Floor 1 435 6 sq.ft. 0 0 0 1,358 S Wall 298 sq.ft. 0 0 0 563 Window 53 sq.ft 2,534 0 2,534 668 E Wall 351 sq.ft. 92 0 92 663 W Wall 216 sq.ft. 0 0 0 408 Window 95sq.ft 1 178 0 1 178 1 197 Door 40 sq.ft. 1 102 0 1 102 538 Leakage Summer 144 cfm 0 0 0 0 Leakage Winter 247 cfm 0 0 0 11,411 Ceiling 1 435.6 sq.ft. _1,001 0 1 001 1 809 PeopleNent 10 people 2,500 2,000 4 500 0 Ventilation 200 cfm 0 0 0 9,240 Infiltration Summer 43.08 cfm 0 0 0 0 Infiltration Winter 64 62 cfm 0 0 0 2,985 Lights 960 watts 3,936 0 3 936 0 Whole Building All Components 12,343 2,000 14,343 30,840 (1 tons) HVAC -Celc Commercial 4.0 by HVAC Computer Systems Ltd. Load celaladona are earimelee only, actual lade may vary due to woOthor and cornawion dif._. o' I I 2/5/2007 888 736 -1101 02/08/07 12 37 FAX 3606812086 Page 1 Report Prepared By- Peninsula Heat, Inc. For Cooper Bldg I Space #2 [Copy 1] Port Angeles, WA Building Component HVAC -Calc Commercial 4 0 by HVAC Computer Systems Ltd. Peninsula Heat a04 Design Conditions. Port Angeles; Latitude: 48; Time 1 PM Indoor Outdoor Summer temperature: 75 Summer temperature: 69 Winter temperature: 70 Winter temperature: 27 Relative humidity 50 Summer grains of moisture: 67 Daily temperature range: 18 lI Commercial Heat Loss and Heat Gain Calculation 2/8/2007 Sensible Latent Total Total Gain Gain Heat Gain Heat Loss (BTUH) (BTUH) (BTUH) (BTUH) Floors 0 0 0 1761 Walls 0 0 0 1 103 Windows 1 '131 0 1 131 968 Doors 842 0 842 275 Door Leakage 0 143 143 5,913 Partiti_ons___ 0 0 0 0 Ceilings 919 0 919 2,507 Skylights 0 0 0 0 Duct 0 0 0 People 3,500 2,800 6,300 0 Ventilation 0 571 571 13,244 Infiltration 0 119 119 4,138 Lights 3,936 0 3 936 0 Miscellaneous 0 0 0 0 Whole Building All Components 10,328 3,633 13,961 29,909 (1 tons) Loan OalalaUons are estimates only, 801u81 10809 mar Vary due to reather eM rdnsL'uesien d 888 736 -1101 02/08/07 12 37 FAX 3606812086 Peninsula Heat Page 1 Commercial Heat Loss and Heat Gain Calculation 2/8/2007 Report Prepared By Peninsula Heat, Inc. For Cooper Bldg Space #2 [Copy 11 Port Angeles, WA Design Conditions. Port Angeles, Latitude: 48; Time 1 PM Indoor Outdoor Summer temperature: 75 Summer temperature: 69 Winter temperature: 70 Winter temperature: 27 Relative humidity 50 Summer grains of moisture: 67 Daily temperature range: 18 Building Component Sensible Latent Total Total Gain Gain Heat Gain Heat Loss (BTUH) (BTUH) (BTUH) (BTUH) Floor 1,943.5 sq.ft. 0 0 0 1 761 W Wall 63 sq.ft 0 0 0 95 Window 45 sq.ft. 558 0 558 581 SW Wall 58 sq.ft 0 0 0 87 Window 30 sq.ft. 573 0 573 387 Door 20 sq.ft 842 0 842 275 Leakage Summer 70 cfm 0 143 143 0 Leakage Winter 125 cfm 0 0 0 5 913 E Wall 612 sq.ft. 0 0 0 921 Ceiling 1 943.5 sq.ft. 919 0 919 2,507 PeopleNent 14 people 3 500 2,800 6 300 0 Ventilation 280 cfm 0 571 571 13,244 Infiltration Summer 58 32 cfm 0 119 119 0 Infiltration_ _Winter 87 48 cfm 0 0 0 4 138 Lights 960 watts 3,936 0 3 936 0 Whole Building All Components 10,328 3,633 13,961 29,909 (1 tons) HVAC -Calc Commercial 4 0 by HVAC Computer Systems Ltd. Load calculations are estimates only actual loads may vary due to weather and construction ddferences 888 736 -1101 IJ 05 02/08/07 12 37 FAX 3606812086 Page 1 Peninsula Heat Q 06 Commercial Heat Loss and Heat Gain Calculation 2/8/2007 Report Prepared By Peninsula Heat, Inc. For Cooper Bldg Space #3 (Copy 1] Port Angeles, WA Design Conditions' Port Angeles; Latitude: 48' Time 1'00 PM Indoor Outdoor Summer temperature: 75 Summer temperature: 69 Winter temperature: 70 Winter temperature: 27 Relative humidity' 50 Summer grains of moisture: 67 Daily temperature range: 18 Building Component Sensible Latent Total Total Gain Gain Heat Gain Heat Loss (BTUH) (BTUH) (BTUH) (BTUH) Floors 0 0 0_ 1 589 Walls 0 0 0 752 Windows 844 0 844 697 Doors 84 2 0 842 585 Door Leakage 0 196 196 8,183 Partitions 0 0 0 0 Ceilings _693 0 693 1 890 Skylights 0 0 0 0 Duct 0 0 0 0 People 2,500 2,000 4,500 0 Ventilation 0 408 408 9 460 Infiltration 0 0 0 0 Lights 3 936 0 3,936 0 Miscellaneous 0 0 0 0 Whole Building All Components 8,815 2,604 11,419 23,156 (1 tons) HVAC -Calc Commercial 4 0 by HVAC Computer Systems Ltd. Load calaladons are estimates only, actual loads may very due to 'mover and o nstr elon ddlerenws. 888 736 -1101 02/08/07 12 37 FAX 3606812086 Peninsula Heat a 07 Page 1 Commercial Heat Loss and Meat Gain Calculation 2/8/2007 Report Prepared By Peninsula Heat, Inc. For Cooper Bldg Space #3 [Copy 1] Port Angeles, WA Design Conditions: Port Angeles; Latitude: 48 Time 1 00 PM Indoor' Outdoor Summer temperature: 75 Summer temperature: 69 Winter temperature: 70 Winter temperature: 27 Relative humidity 50 Summer grains of moisture: 67 Daily temperature range: 18 Building Component Sensible Latent Total Total Gain Gain Heat Gain Heat Loss (BTUH) (BTUH) (BTUH) (BTUH) Floor 1 465.3 sq.ft_ 0 0 0 1 589 SW Wall 58 sq.ft. 0 0 0 87 Window 30 sq.ft. 573 0 573 387 Door 20 sq.ft. 842 0 842 275 Leakage Summer 70 cfm 0 143 143 0 Leakage Winter 125 cfm 0 0 0 5 913 N Wall 442 sq.ft. 0 0 0 665 Window 24 sq.ft- 271 0 2_71 310 Door 20 sq.ft. 0 0 0 310 Leakage Summer 26 cfm 0 53 53 0 Leakage Winter 48 cfm 0 0 0 2,270 Ceiling 1 465.3 sq -ft. 693 0 693 1 890 PeopleNent 10 people 2,500 2,000 4 500 0 Ventilation 200 cfm 0 408 408 9 460 Infiltration Summer 0 cfm 0 0 0 0 Infiltration Winter 0 cfm 0 0 0 0 Lights 960 watts 3,936 0 3,_ 936 0 Whole Building All Components 8,815 2,604 11,419 23,156 (1 tons HVAC -Calc Commercial 4.0 by HVAC Computer Systems Ltd. Load calculations as ctinsates only, actual loads may vary duo to vmxhw and 688 736 -1101 02/08/07 12 37 FAX 3606812086 Peninsula Heat U] 08 Page 1 Commercial Heat Loss and Heat Gain Calculation 2/8/2007 Building Component Report Prepared By' Peninsula Heat, Inc. For Cooper Bldg Space #4 Port Angeles, WA Design Conditions: Port Angeles; Latitude. 48 Time 1 PM indoor Outdoor Summer temperature: 75 Summer temperature: 69 Winter temperature. 70 Winter temperature: 27 Relative humidity 50 Summer grains of moisture: 67 Daily temperature range: 18 Sensible Latent Total Total Gain Gain Heat Gain Heat Loss (BTUH) (BTUH) (BTUH) (BTUH) Floors 0 0 0 1,409 Walls 0 0 0 1209 Windows 1,487 0 1,487 736 Doors 1 490 0 1 490 275 Door Leakage 0 29 29 1,277 Partitions 0 0 0 0 Ceilings 720 0 720 1,9 Skylights 0 0 0 0 Duct 0 0 0 0 People 2,750 2,200 4,950 0 Ventilation 0 449 449 10 406 Infiltration 0 93 93 3,237 Lights 2,952 0 2,952 0 Miscellaneus 0 0 0 0 Whole All Components 9,399 2,771 12,170 20,511 (1 tons) HVAC -Calc Commercial 4 0 by HVAC Computer Systems Ltd. Load calculations ale eeomales only actual loans may very cue Ic weather and coneducUon differences. 688 736 -1101 02/08/07 12 37 FAX 3606812086 Peninsula Heat lj09 Page 1 Commercial Heat Loss and Heat Gain Calculation 2/8/2007 Report Prepared By Peninsula Heat, Inc. For Cooper Bldg Space #4 Port Angeles, WA Design Conditions: Port Angeles; Latitude: 48; Time 1 PM Indoor Outdoor- Summer temperature: 75 Summer temperature: 69 Winter temperature: 70 Winter temperature: 27 Relative humidity 50 Summer grains of moisture: 67 Daily temperature range: 18 Building Component Sensible Latent Total Total Gain Gain Heat Gain Heat Loss (BTUH) (BTUH) (BTUH) (BTUH) Floor 1,521 sq_ft 0 0 0 1 409 N Wall 339 sq.ft 0 0 0 656 Window 12 sq.ft 136 0 136 155 S Wall 286 sq.ft. 0 0 0 553 Window 45 sq.ft. 1 351 0 1,351 561 Door 20 sq.ft. 1,490 0 1 490 275 Leakage Summer 14 cfm 0 29 29 0 Leakage Winter 27 cfm 0 0 0 1,277 Ceiling 1,521 sq.ft. 720 0 720 1 _9 PeopleNent 11 people 2,750 2,200 4 950 0 Ventilation 220 cfm 0 449 449 10 406 Infiltration Summer 45 63 cfm 0 93 93 0 Infiltration Winter 68A45 cfm 0 0 0 3,237 Lights 720 watts 2,952 0 2,952 0 Whole Building All Components 9,399 2,771 12,170 20,511 (1 tons HVAC -Calc Commercial 4.0 by HVAC Computer Systems Ltd. Load wlalaoorts are estimates only, actual loads may very cue to weather ene conslruceon 888 736 -1101 02/08/07 12 37 FAX 3606812086 Peninsula Heat 1110 Report Prepared By Peninsula Heat, Inc. For Cooper Bldg Space #5 Port Angeles, WA 4- I Page 1 Commercial Heat Loss and Heat Gain Calculation 2/8/2007 Design Conditions: Port Angeles; Latitude: 48, Time 1'00 PM Indoor' Outdoor Summer temperature: 75 Summer temperature: 69 Winter temperature: 70 Winter temperature: 27 Relative humidity 50 Summer grains of moisture: 67 Daily temperature range: 18 Building Component Sensible Latent Total Total Gain Galn Heat Gain Heat Loss (BTUH) (BTUH) (BTUH) (BTUH) Floors 0 0 0 1 607 Walls 0 0 0 2,115 Windows 2,234 0 2,234 1 523 Doors 1 863 0 1,863 550 Door Leakage 0 58 58 2,554 Partitions 0 0 0 0 Ceilings 923 0 923 2,515 Skylights 0 0 0 0 Duct 0 _0_ 0 0 People 3,500 2,800 6 300 0 Ventilation 0 571 571 13,244 Infiltration 0 119 119 4,151 Lights 3,936 0 3,936 0 Miscellaneous 0 0 0 0 Whole Building All Components 12,456 3,548 16,004 28,259 (1.5 tons HVAC -Calc Commercial 4 0 by HVAC Computer Systems Ltd. Load celouletlona are estimates only, actual bade may vary due to weather and onnstrudion dif 888 736 -1101 02/08/07 12 37 FAX 3606812086 Peninsula Heat Page 1 Commercial Heat Loss and Heat Gain Calculation Report Prepared By Peninsula Heat, Inc. For Cooper Bldg I Space #5 Port Angeles, WA Design Conditions: Port Angeles; Latitude. 48 Time 1 PM Indoor Outdoor Summer temperature: 75 Summer temperature. 69 Winter temperature: 70 Winter temperature: 27 Relative humidity 50 Summer grains of moisture. 67 Daily temperature range: 18 Building Component 2/8/2007 Sensible Latent Total Total Gain Gain Heat Gain Heat Loss (BTUH) (BTUH) (BTUH) (BTUH) Floor 1 950 sq.ft. 0 0 0 1 607 N Wall 410 sq.ft. 0 0 0 793 Window 20 sq.ft. 226 0 226 258 Door 20 sq.ft. 373 0 373 275 Leakage Summer 14 cfm 0 29 29 0 Leakage Winter 27 cfm 0 0 0 1,277 W Wall 298 sq.ft. 0 0 0 577 Window 53 sq.ft. 657 0 657 684 S Wall 385 sq.ft. 0 0 0 745 Window 45 sq.ft. 1 351 0 1 351 581 Door 20 sq.ft. 1 490 0 1 490 275 Leakage Summer 14 cfm 0 29 29 0 Leakage Winter 27 cfm 0 0 0 1,277 Ceiling 1 950 sq.ft 923 0 923 2,515 PeopleNent 14 people 3,500 2,800 6,300 0 Ventilation 280 cfm 0 571 571 13,244 Infiltration Summer 58 5 cfm 0 119 119 0 Infiltration Winter 87 75 cfm 0 0 0 4 151 Lights 960 watts 3 936 0 3,936 0 Whole Building All Components 12,456 3,548 16,004 28,259 (1.5 tons HVAC -Calc Commercial 4 0 by HVAC Computer Systems Ltd. Lae calculations am estima es only actual loads may vary due to vneelner and conslructlon dirterences. 888 736 -1101 T L C A T E CI I Cc) Page oL\ ;7,k-k p t ar C)kail\ E N S i C °�F' Vroaknody got ecoy-14- OiC) V \w) j):0,,.'),n,) V16. l.) DRAINAGE, SEDIMENT AND EROSION CONTROL PLAN For the Construction of a Commercial Building Upon Parcel Number 063000- 513840 Lots 10 -12 of Block 38, Township of Port Angeles Prepared for James M Cooper and Lindberg /Smith Architects Prepared by Robert A. Leach, P E info @nti4u corn August, 2006 NTI Engineering and Land Surveying 717 South Peabody Port Angeles, WA 98362 (360) 452 -8491 voice (360) 452 -8498 fax AUG 2 3 2006 II 1 H I. INTRODUCTION NTI Engineering and Land Surveying (Northwestern Territories Inc was retained by James M Cooper and Lindberg /Smith Architects to develop a grading drainage erosion and sediment control plan for the construction of a new Commercial Building upon property (parcel number 063000 513840) located on the northeast corner of the intersection of Front and Francis Streets in Port Angeles in Clallam County This report is a summary of the analysis and describes the type of storm water collection detention and infiltration system proposed to collect, treat and detain the storm water runoff from the commercial building and the developed site II. DESCRIPTION OF SITE The project is located on a parcel of land containing an existing building and parking facilities which will be completely removed for site re- development. The project site is made from three (3) city lots (21 000 sf total area) and is mostly open and grassy with the exception of the existing building a parking area on the west side of the building and a gravel driveway off of the alley The site matches the elevations of Front Street on the south and the alley on the north but the northwest portion of the site remains level while the alley and Francis Street drop in elevation creating a 2 slope up to the site grade Aerial photographs from approximately 1972 from the Soil Conservation Survey of Clallam County (SCS) and 2005 from the Clallam County Website are included in this document's appendix for reference along with a site topographic map showing existing contours and site improvement plans The proposed collection system will intercept the drainage from the buildings and parking lot, transport it to an underground detention facility where it will be detained and control released to the City of Port Angeles storm drain in Front Street. Oil /water separation will be accomplished by the use of catch basin inserts in CB #1 CB#4 (model Ultradrain Guard P /N- 11090U) The system is designed for the 25 year 24 hour storm per DOE's 1992 Storm Drainage Manual The soils on the site per the Soil Conservation Survey of Clallam County is #14 Clallam (hydrologic group `C III. DESCRIPTION OF PROPOSED DRAINAGE FACILITIES This 'L shaped building project has two parking areas 1) along the alley north of the new building and 2) along the inside of the "L in the southwest of the site In order to collect drainage from both parking lots a pipeline is proposed to run through a pedestrian causeway connecting the two parking areas The site will use graded and paved slopes and topographic characteristics to collect, detain and control release the collected storm runoff Roof drains are envisioned as being collected and piped into the collection /detention system or can be allowed to discharge to the paved surface for surface flow where not in conflict with pedestrian traffic Given the limited infiltration capability of the Clallam soils, no infiltration is anticipated Page 1 IV. CALCULATIONS 1. Desian Method All drainage facilities have been designed using the Santa Barbara Urban Hydrograph (SBUH) method and utilize a SCS Type 1A storm of 24 hour duration as required by the Washington State Department of Ecology's storm drainage manual as adopted by Clallam County for projects with more than 5000 SF of impervious surfaces An analysis has been performed using the 2 10 and 25 year storm event for both the pre and post construction conditions for infiltration Other values for the 6 month and 100 year storms have been calculated but are not used in this analysis The Water Works computer software from Engenious Systems has been used to model the site A simulation report is included in this document's appendix for reference 2. Desian Criteria a The following numbers for Port Angeles rainfall were used for the primary variable's input values that were used in this analysis 6 mo 24 hr rainfall for 1 90" 60% of the 2 yr value 2 yr 24 hr rainfall for 3.20" per NOAA precip atlas 10 yr 24 hr rainfall for 4 40" per NOAA precip atlas 25 yr 24 hr rainfall for 5 30" per NOAA precip atlas 100 yr 24 hr rainfall for 6 30" per NOAA precip atlas b Impervious Areas Post development pavement curve number 98 Weighted average pre development (bldg driveway) 95 42 c Pervious Area Pre development (grass yard 75 curve number 86 Post development (grass yard 75 curve number 86 d Storm Type SCS Type 1A, duration 24 hours e Time of Concentration calculated by software based upon input recognizing existence of drainage collection facilities f Infiltration rates for the Clallam Soil (type `C 0 6 2 0 in /hr) 30min /in max if considered due to decorative pond design infiltration is assumed to be zero Page 2 The elevations chosen in the simulation are on an assumed local datum relative to the bottom of the Control Release Unit (CRU) at 100 00 and have a detention over flow elevation of 101 98' The actual elevation of the outlet of the CRU is 84 29' V. EROSION CONTROL Due to the site s flat topography and small size erosion is not a serious issue but to minimize risk of silt and other contaminants from leaving the project site a series of I Erosion Control elements have been identified utilizing Best Management Practices (BMPs) These BMPs including construction period catch basin filters on all on -site catch basins and a gravel construction entrance as shown in this document's appendix. If conditions warrant, a silt fence is also detailed for installation to solve localized problems VI. SUMMARY AND CONCLUSION The following summary of both drainage and erosion control features are also illustrated on the included schematic diagrams and facility drawings 1. Drainage An on -site drainage collection and control release discharge system is proposed for this project. This system will collect the storm runoff from roof and paved areas 25 year recurrence storm of 24hr storm duration Normal and over flow runoff from the detention system will discharge into the City's exiting storm drain system located in Front Street. In the event of a storm in excess of the system s capacity (100 yr storm) the site will overflow into the street. Summary Base outlet elevation 100 00' (84 51') Maximum water detention elevation 101 98' (86 49') Overflow elevation 101 98' use 102 00 (86 51') Center of Lowest orifice elevation 99 9' (84 41 dia 1 90" (1 -7/8 Mid -level orifice elevation 101 39' (85 90 dia 2.24" (2 -1/4 High -level orifice elevation 101 86' (86 37 dia 1 36" (2 -3/8 Maximum stored volume 510 CF for the 25 yr storm event Calculated detention volume 620+ CF overflow Notes 1 Sufficient slope exists for the 8" pipe from the CRU assembly to the 18" storm drain in Francis Street to drop the entire drainage system 0 5' to Page 3 Summary V. LIMITATIONS increase the amount of cover over the 24" HDPE pipe at CB#4 for additional pipe protection 2 The sanitary sewer main is located in the alley and is over 10' deep The elevation of the side sewer connection to this sewer is unknown and may need to be adjusted to fit under the storm water collection detention system 2. Erosion Control Erosion and sediment control will be provided by the use of BMPs identified in the DOE 1992 Storm Drainage Manual and will include a selection of silt fencing and straw filters Silt fence if needed at trouble spots Construction period catch basin filters on all new and existing catch basins Gravel construction entrance to the project to be at the contractor's preferred location (the facility is shown off of Francis Street on the plans for permitting purposes only) This report has been prepared for the exclusive use of James M Cooper and Lindberg /Smith Architects for the construction of a new Commercial Building at the intersection of Front and Francis Streets in Port Angeles Clallam County Washington State The recommendations in the report apply only to the property that was examined and they are not applicable to other areas The investigation and recommendations contained in this report are based upon site conditions as they existed at the time of our site inspections During construction if subsurface or other conditions are discovered that are significantly different from those described in the report, NTI should be advised at once so that we can review the conditions and reconsider our recommendations where necessary Unanticipated soil conditions are commonly encountered on construction sites especially when the topography has been altered years ago Such unexpected conditions frequently require that additional expenditures be made to attain a properly constructed project. We recommend that a contingency be established in the project budget and schedule to cover unexpected conditions Page 4 Within the limitations of scope schedule and budget, our services have been executed in accordance with generally accepted professional engineering principles and practice This warranty is in lieu of all others either expressed or implied NTI Engineering and Land Surveying Robert A. Leach, P E Principal Engineer H \Lindberg First and Francis \Site Drainage Plan b wpd Page 5 EXPIRES 12/30/2006 DETAIL VARi BLE. 90.70_ A( H w w 1" 24 o v Ex at8:.. CONCRETE v7 X+ STORM DRAIN U- tL REMOVE AND REPLACE CONCRETE SIDEWALK 1 _•f EX. SOW RIM -90.10 FL -84.40 35' NEST OF EAST MARGIN OF FRANCIS CRAFT ON 8" TEE CALC. FL. ELEV. OF 18 ■80.45 NOTIFY ENGINEER IF ELEVATION OF PLOKINE IS GREATER THAN 81.00' PATCH ROADWAY I REMOVE EXISTING EX 5OMH DRIVEWAY NEB RI44-89.50 REMOVE AND FL =80.5 REPLACE 48'± WEST OF CURB AND EAST MARGIN GUTTER OF FRANCIS AND 12' SOUTH OF NORTH MARGIN OF FRONT STREET MA TCH NE CONSTRUCTION MATCH I EXITING IICONCRETE l WALL VARIABLL IL r `I 9e,6or •ao.7o Al 1 TCH� 15 w; �89.1J. i.4.7�6x. NA.TCH .EXISTING. r89 r3. CRU RIMa89.2 -J 12' 12' a 06°1 OC '-7'1 0� 90 To p/ 9 9° 9' t p 9'0'' e FULL o L 5 II HEIGHT VARIABLE CURB 4 9070 II 90.60TCJ 90.10' ASPHALT PAVING 1k' DETENTION PIPE' SEE' -DET TO THE RIGHT l "59x.1' 89:< 8 9;IF RwaB &92. l 1==C V' sl -9o. 0orc-- 9o. oOTC 89.50 A 89.50 RMA/1(t L ISJNV4 .N WAIK•S 70' 'S .90:23 9023 AN 0 EXISTING ASPHALT PAVING 29' r HEIGHT CURB NfIEELCHAI RAMP IT S. II '90?0O: 24' vARI Q P. �I1R8 90.70 VARI SIC CU 9 Da0 90. 0TC 90.70 00,01 9-50 8 9 0 REMOVE AND REPLACE I CURD AND GUTTER r F ,0 CS RONT STREET a P AIVD LOCA ZII V a EXISTING 8 STORM DRAIN Ai�PROXIMA7ELY 66' DEEP �IFY 0_P IN 25.5' ATCH EXISTING 9 90.10 I 9°' 0 FULL HEIGHT CURB i i -RFNO4c. e4L ,0116- Melt.VALi a 1Ew SIOENALK c ci to ce 0 ce '1 p0 0 ID m FL -80.87 CALC 7' B" HOPE 0 0.5 5 12 8" HOPE O 2.0% 58 D? E 6 JX a FC =84.51 EX. SDMH I ;n EXISTING ,4 CONCRETE SIDEWALK SCALE IN FEET 20 CRu (4' C8 TYPE 2) RIM=89.2J a- 84.51- FL -84.51 SOLID U0 DRAIN" Celt 15- RIM -88.00 T1 -86.00 -a64i 8" HOP O.SA 6J' 24" HOPE 0 0.5% 24'4B' ECCENTRIC REDUCER [70AI BOTTOM ECCENTRIC REDUCER ON BOTTOM PIPING DETAIL NO SCALE Underground Utilities Location Services Call TOLL TREE CB/2 RIM -89.78 FL`5.68CO 1J' 8" HOPE O 0.5% FL -95.25 24 ECCENTRIC REDUCER ON BOTTOM -CO ON 24" (VENT IN PLANTER) f -100' 24" HOPE 0 0.5% (102' INCLUDING 8 AFL -85.08 FL =aa 77�_ 5' 1 STORAGE C APACITY =6201 CF MINIMUM NEEDED =510 CF 1- 800 424 -5555 NOT LESS THAN TWO BUSINESS OATS BEFORE 01001N0 6'± 1 NOTES, I. INSTALL ULTRAORAIN GUARD P/N- 110900 CATCH BASIN INSERT FOR POLLUTION CONTROL 2. ADJUST'SLOPE OF 8' HOPE TO MATCH ACTUAL ELEVATION OF 18 3. SANITARY SEWER CONNECTS IN ALLEY. COORDINATE RE -USE OF EXISTING CONNECTION ELEVATION AND LOCA ZION N1 TH STORM DRAIN COLLECTION LINE J6' B0 HOPE 11 0 J.5X CB /4 mm-8E92 =85.06 1.9' 1.9' COVER (J" WALL) O f P ST R =84.75 8 CROSS 74 8 HOPE O 0.5% FL -85.62 CB/J RIM -89.38 FL -86.88 4 C U z REMOVE AND REPLACE CONCRETE SIDEWALK REMOVE EXISTING DRIVEWAY WEB REMOVE AND —4-- REPLACE CURB ANO GUTTER MATCH NE CONSTRUCI7ON W L 3 1 =y O ti0 N N U N I Un W W MA 7 I C9I 72• I 12' T II EXISTING I I CONCRETE WALL, VARIABLE `I M I TCH I I 4." 3 2 N j_ MATCH e EXISTING Z 2. N N VARIABLE CURB L VARIABLE I fURB •T T II ZERO 6• it 6' HEIGHT CURB TYP WHEELCHAI RAMP I I _I II/ j 0 II FULL `P HEIGHT CURB II II II g 0 80 II I II VARIABLE rLMVt tAlSNt. ry U S /Fc W A /K CURB r �I FRONT STREET EXISRNG ASPHALT PAVING 29' TAPER CURB TIP. 3' 24' 25.5' MA rCH EX/SRNC I FULL HOCHT I L CURB REMOVE AND REPLACE CURB AND CUTTER "I 0 I F R£MOl2 tA/S I /N �t, ,ylut�C�� tNEW T 1 SIDEWALK �LJ CONCR£t E'F I SIDEVIAL 0 ID tezi SCALE IN FEET 21 2 ROOD POSTS OR EOFNALENT 20 III IIIII .s, fib.• III \�:i� Sr 'I�L�� /e III zs Mw. 1/41 ��y�. 2" MIN •'IW TO a 0111R SPILLS OR APPROVED EO ML "PRONOE FVCL iRODI OF NC INGRE55 /EGRESS A4E4 ENTRANCE SHALL BE MuNrA/NEO CONDIDON WHICH WILL PREVENT TRACKING OR FLOW OF 1410 ONTO PUBLC RIGHTS -OFF- Y THIS MAY REQUIRE PER100/C TOP DRESSING WITH 2 -INCH STONE OR OTHER APPROVED MATERIAL AS CONDITIONS DEMAND. NM) REPAIR AND /OR CLEANO/T OF ANY STRUCTURES USED TRAP SEDIMENT. ALL MATERIALS SPILLED. DROPPED. WASHED, OR TRACKED FROM VEHICLES ONTO ROADWAYS OR NTO STOMA DRAINS MUST BE REMOVED /I/MEDIATELY SECnoN SITE ACCESS DETAIL WHERE CATCH 84SIN LIES R ROUTE OF ACCEs5 USE SIT SACK MANUFACTURED BY ACE INC. OR EQUAL. CILIA AFTER EACH RUN -OFF Mar O C2 FILTER FABRIC FENCE INLET FILTER DETAIL 1407 TD SOU NOT SCALE 212• M000 STARE FTER FABRK RUNOFF SE ATER WITH SCOYENl� LOW BURIED TRIER FABRIC PROME C/C/N. 11IR0 SURFACE ro EUM/NATE TRACKING OF SOIL ONTO STREET. SURFACE MATERIALS MAY MCLVOE 0/1/88 SPILLS. CRUSHED ROCK OR OTHER NON-SOIL OR NON-SOUND MATERIALS 6' UV W000 POSTS OR EQUIVALENT FILTER FABRIC FENCE AS NEEDED Nor TO SCALE Underground Utilities Location Services Call: TOLL FREE -800- 424 -5555 NOT LESS THAN TWO BVSONESS DAYS BEFORE mama DOVICS L O c w o 8` 13 b a ct Cg W 2 u Li! W b I- W o a Z a SIDEWALK WITH PLANTING STRIP DUMAN JOINT 8 SIDEWALK AT CURB 3' Mo. I 5' I. 28 SLOPE COMPACTED SUBCRADE L .3 t/2 MNImUm 6" AT DAVERAIS CRAWL _5ECTION A-A TI TOP OF CURB AT APPROACH 1"R 5 I/2" LV' R .7a 0.5 NORM j.7 3/4j OR 12 7/t6' 2.78 SOWN .3 NORM /71 CONCRETE BARRIER CURB NOT TO SCALE SEE NOTE /I EXPANSION JOINT SIDEWALK INSTALLATION NOT TO SCALE J t/2" WNIMUW V AT DRIVEWAYS 6' \,1 2% SLOPE I •I N.• /‹.,‘,C IECTION NOTES. SIDEWALK LOCATION ID BE APPROVED BY CITY CHOKER. 2. EXPANSION JOINTS SHALL BE ASPHALT IMPREGNATED JOINT INITERIAL J. EXPANSION JOINTS SHALL SE 1/4 Hock. FULL DEPTH AND AT 2V-0" INTERVALS. DUMMY JOINTS SHALL BE 1/8' SACK. OEEP AND AT 5 INTERVALS. 5. ALL UTILITY POLES. METER SOARS. ETC. IN SIDEWALK AREA SHALL HAW EXPANSION JOINT MATERIAL (FULL DEPTH) PLACED AROUND TIlLS BEFORE PLACING CONCRETE 6. ALL JOINTS SHALL BE CLEAN AND EDGED. 7 EXPOSED AGGRECATE OR SPECIAL SURFACE TREATMENT WORK NOT ALLOWED IN RIGHT-OF-wA InnioLIT APPROVAL. 8. ORNEWA AND SIDEWALK SHALL BE SEPARATED FROM OTHER CONCRETE WORK uSING EXPANSION AUITERTAL. 9. CONCRETE SHALL BE CLASS 3000. 10, HERBICIDE TO BE PLACED UNDER AvING. CURB AND SIDEWALK PRIOR TO PLACING OF MATERIALS. SIDEWALK SHALL BE 2% SLOPE FROM TOP OF OMB. 12. SIDEWALK WIDTHS mom ARE FOR RESIDENTIAL AREA COMMERCIAL ARO DOWNTOWN AREAS YAWNS SHALL BE ID' AND I RESPECTIVELY. PAVEMENT SECT/ON NOT TO SCALE R.O.W. v T. COMPACTED SulIGRAISO t TOP Or CURB AT DRIVEWAY CEMENT CONCRETE BARRIER CURB AND GUTTER PER WSOOT STANDARD PLAN F-I. A 12" MN At JO' MA% or. NCR 1 CEMENT CONCRETE CURB AND GUTTER Not TO ScALE NOTES FORMS SHALL BE STEEL. 11000 MAY BE APPROVED FOR AREAS REOTARINC SPEC/AL FORMING. 2. FORMS SHALL BE TRUE To LANE GRADE ANO SECURELY STAKED. J. EXTRUDED CURBS REQUIRE PRIOR APPROVAL BY CITY ENO/SEER. ME EDGER OR BUILT ON BUILTTNIO CTRL/ CUR-B RATUS BEONFOLRMWOWER BY rAcE OF CURB SHALL BE FORMED BY THE FACE raw CONCRETE SHALL BE CEMENT CONCRETE CLASS 3000 WHEN HATCHING DR/STING AVEmENT GRADE AvEmeIT SHALL BE SAWCUT 2'.-6" FROM BACK OF cuRa 7. HERBICIDE II) BE PLACED UNDER PALING. CURB AND ADJACENT SIDEWALK PRIOR TO PLAONG OF MATERIALS. 8. JOINTS SHALL BE PLACED AT ALL ALLEY ANO ORIVEWA RETURNS STRUCHIRES CURB RAMPS AND AS Atom ON PLANS. 9. ALL .AONTS SHALL BE CLEAN ANO EDGED. EXPANSION JOINTS SHALL BE VA NCI. MACK No 20 FT. INTERVALS OR AS DIRECTED. EXPANSION JOINTS SIMI. BE ASPHALT IMPREGNATED JO/LOT MAIERml. 12. oRDUAI...,Mr DIRECTED. HAU. S BE 1/8 'NCH 71107 AND 20 FT INTERVALS r_t Demur JOINTS SHALL BE CONSTRUCTED TO AINTAALM DEPTH OF NOT TO EXCEED ExpANSION JOINT 1/2 RISE 6' cOvPACIED SuBGRACE ALL NOW ANO MATERIALS ID BE A wIN GuRRENT STAFOAR0 "PONCA notrS nvw ROAR BRIDGE AND mumaPAL GaysMUCTIoN: TrA9ANGION STATE OCRARImair GrAmmarTAIKH AMERICAN AVOW •003 ASSOCunat REPLACE ACTEwALKS 111111 CoNCREIE IN ORtvEwA AREA ■T" N' r SECTION A-A DRIICHAY BYPASS REWIRED W0E7V SIDEWALK IS AT CURB NO7ES. 1. DMVEWA LOCATION TO BE APPROVED BY CITY plegNEER. 2. WHEN SIDEWALK IS NOT PRESENT: DRIVEWAY APPROACH WU. BE CONSMUCTED TO MEET FUTURE SIDEWALK GRADE J. SIDERMIX CROSS SLOPE AtALL NOT EXCEED 2% 54 DRIVEWAY AND BYPASS AREAS. °MENA APRON AND SIDEWALK SHALL BE CONCRETE AND SEPARATED PROM OTHER CONCRETE WORK USING EXPANSION JOINTS. 5. HERBICIDE TO BE PLACED WIDER PAWN° CURB AND SIDEWALK PRIOR TO PLACTNG OF MATERIALS. 6. SIDEWALKS. CURB AND GLITTER PER CITY STANDARD PLANS. EXPOSED AGGREGATE WORK OR SPECK SURFACE TREATMENT NOT ALLOWED IN RIGHT-OF- INTHOUT APPROVAL IV LENGITUOINAL DWAIN JOINTS yr MICR AND 1 DEEP. SHALL BE AT INTERVALS NOT 10 EXCEED 15 FEET AND DRIVEWAY APRONS. SHALL BE CLASS 3000 10. ORNEWAY PAVING MAMMALS. OTHER MAN CONCRETE AMY BE USED SEWN rue SIOEwNX ANO R/W RIM OTT ENGINEER APPROVAL. I EXPANSION JOINTS STOLL BE I/4 MICR. FULL DEPTH. ASPHALT RIME:MATED JONA MATERIAL.. IS. SIDEWALK wrDiNS SmOvw ARE FOR RESIDENTIAL AREAS COMMERCIAL AND AREA PROMS SMALL BE TO' A//WI SIDEWALK INSTALLATION NOT TO SCALE MEET SIDEWALK OR Fl//I/RE SIDEWALK CRADC r mAxmlum SLOPE AV SIDEWALK AREA ':«A•ec.c 5 MIN WI' NoTE BE EQUALLY SPACED IN CALL NW FOILS AvsPECIToN VT CITY 1 Pear TO POURING CONCRETE NOTFS, ACP PATCH SHALL BE ROLLED NOT VIBRATED. 2. re 12" hiat OVERLAP alitIr7/ ttlit it= i 0 14: NIT TO saw C.O. RACKFILL SPFCIFICAT1ONS 2600 LBS. OF 0.375 M. AGGREGATE 800 LBS. OF STANDARD CONCRETE SAND PA LBS. OF PORTLAND CEMENT APPROX. GAL. OF WATER ME NOWT OF ATER IS CRITICAL FACTOR TO SET uP MME AND SHOuLD BE ADDED T THE SITE. IV BE USED FOR ALL EXISTING AM) 51 715 AND ALLEYS. BOOTLE LOCATION TO -0' SOS/SD CURB OR EDGE OF AMC LwLESS OTHERWISE APPROVED IN ADVANCE BY CITY ENGINEER 5. WHERE PAVEMENT JO/NT IS LESS 1/SIN -0" FROM SAWCur PIE AvEMENT SHALL BE REMOVED TO IT/AT Jormr. TEMPORARY PATCHTTO 107114 ASPHALT OR PLACEMENT OF STEEL PLATES IS REOuIRED WEN TRAFFIC RILL CROSS CD?' FOR ATOM' THAN 24 HORS P5111/OUT PERMANENT RESTORATION. STEEL PLATES SHALL HALE COLD ATCH WEDGES ON TRAFFIC EDGES CALL FOR INSPECTOR MoR TO PLACING cor BACOILL. REDOING 8.0. .0 MA 07.3 ro er .0.11.7 FM CURREN, 57.0.0 SUM OF 17.1/670* MO% .071r... 1•00717 AMC. 00,4 CONTROL LED DENSITY BACKFII,L (ODE) NOT TO SCALE Underground Utilities Location Services Coll: TOLL. TREE 1-800-424-5555 NOT LESS THAN TWO BUSINESS DAYS BEFORE 0100180 ASPHALT AILMENT OR CLASS 8 FCC PAVEMENT 1- (mai EARLY) HATCH EXISTING AILMENT TIRE AND OEPM, SEE NOTE r Curs SHALL BE SANCVT. SEE NOTE EXPIRES 1/30/3811 SI RE RE ID a a OLMPC FOUNDRY IRAN[ SM 52-A NTH J/16 NON -SAO DRMOND PATTERN ON RIW SURFACE FRAME /NO GRATE OR RING 1110 L. RAT SLAB COYER IIO TAR FILLETS 1F 48. 044_6. 'FOR SEPARATE CAST IN PLACE DETAIL CAST IRON RING AND COYER PER WSLOT STAAD4RO RAN 8 -186. COYER MARKED SEWER. 0.02 24 DNA f {-4+ STEPS ANO LAOOER 48 SEPARATE UST IN PUCE OR SEPARATE PRECAST BASE RENFDRCNC STEEL (FOR SEPARME BASE ONI.Y) 0.23 50 N/FT IN EACH DIRECTION FOR 48' REMOVABLE SCREW -ON CAP I/2' HOLE FLOP VENT p♦1 j�.�y: 1N4SED GRADE CONCRETE EACASEWENT 6" AC RISER 41 BD105 6' PAC DRAIN PPE 1E MN DRAIN CLEANOUT NOT TO SCALE ADJUST 11000 1O MATCH CURB HECHT (J' ANN. OPENING) RISER OR ADNSTMEN SECION NWONOID5 RENFORCNG STEEL (FOR PRECAST BASE WIN INTEGRAL 01561) 0.11 50 W/FT N EACH DRECTKTN FOR AO' ON RECAST BASE WITH INTEGRAL RISER 'I GRAVEL BOCKFUL FOR PIPE BEWNC. 6' MIN COMPACTED DEPTH FOR -O. 1PREGAST BASS ONLY /J BAH EACH CORNER- /3 BAR EACH SIDE NOTES CATCH BASINS 10 BE CONSTRUCTED N ACCQPCAACE WITH ASIA C -478 (AASRO M -199) M/0 AVM 0 -890 UNLESS O11IERWMSE SHOWN ON PLANS OR N]/ED N HIE STAN014RD SPEL1FIGAT10415. 2. HANDHOLDS N RISER OR ADJUSTMENT SECTION SHALL HONE 3 CLE/R4ACE STEPS N CATCN BASIN SHALL HAW 6" NH. CLEARANCE NO STEPS ARE REOUARED WHEN b' IS OR LESS FOR OETALS SEE Sr.4M0KO PLAN SIKCELIANEOUS CATCH BASIN OETAJS J. ALL RENFLLRCED UST N PLACE CONCRETE SILL BE CLASS 4000. ALL PRECAST SMALL OBTAIN 400 PSI AT 28 CANS. PRECAST BASES SHALL HAVE CUTOUTS OR KNOCKOUTS WIN A WALL THICKNESS CF 2 KNOCKOUTS OR CUTOUT HOLE SIZE /5 EMIR TO PIPE OUTER MMETER PLUS CATCH BASH WALL 1060 KNESS. MA0WUM HOLE SIZE IS Jr FOR 48" 041011 BASIN. MINIMUM 0/STANCE BETWEEN /ONES IS S. ALL BASE REINFORCING STEEL SILL BE PLACED N THE TOP HALE OF THE BASE MIN CLEARANCE. MD STRENGTH SHALL BE 60.000 PSI MN. 6. THE BOTTOM OF TINE PRECAST CANON 8451N MAY BE ROUNDED 8 DESIGN 504 (EARWIG VALUE EOUALS .1300 MN. CATCH BASIN TYPE 2 NOT 70 SCALE 1 -/J BR ACROSS 8077044 FAO/ WAr FRAME A10 GRATE MO' BE INSTALLED NTH FLANGE DOWN OR CAST INFO RISER. PER DETAILS SEE STANOARO PLAN PETAL FRAME AND GRATE FOR CA IRN BASIN AND INLET. S EA PPE MATERIAL 6 PRECAST BASE SECTION I MEASIRFMOIE THE TO') [Y THE A7 BASE s 4 11 01 NOT TO SCALE 1IA5N/D GRADE ,-111.111=111=111.,11.111=111 III III Ili LKECUARO RP( OR C0LN•4.017 TRACER TAPE MNRKLT VA TER' N501.4E0 CONTINUOUS 10 GA/CE TWIG WE FOR SPLICES. USE KING EDI/NOLOGI: NC. 1100a KWIC rWnr MERPROOR WE CONNECTORS OR EOUNALENT (FOR 0104 TO THREE GOUGE WTRES). eRNG 7ONNG WORE UP INTO KKR BONES. BLOWOUTS. 410/14MM RELEASE EYES. ANN SOACE LATERALS (TO 0101146 INCHES OF LID) !,Ores REINFORCED OR RAN COI RETE ALL METAL PIPE IIQ III CPSSP• (5/D. SPEC. 9 -05.20) 5OU0 WALL PK' (STD. SPEC. 9-05.12( PAC PROFILE (S 912(2)) CORRUGATED POLIETNRLENE STORM SEWER PPE —2' CROW 4 N NON- DRAING AREAS II_U Ia' YAY0 PVC PIPE TRENCH DETAIL NOT TO SCALE AS AN ACCEPTABLE ALTERNATE TO ROAR. WIRE ME511 HAVING NINIMU AREA OF 0.11 SOUBRE INCHES PER FOOT WIRE MESH SHAD. NOT BE PLACED N KNOCKOUTS. 1. WE KNOCKOUT 0AMETER SHALL NOT BE GREATER MAN 20 KNOCKOUTS SHALL HAW WALL THICKNESS OF 2' MIPOMUM II) 2.5 MlK /MUM. PROACE A .5" MIN MUM GAP BETWEEN THE KNOCKOUT WALL AND THE OUTSIDE OF THE PIPE AFTER THE PIPE IS INSTALLED. FILL THE GAP WITH JOINT MORTAR CCOROONCE WITH 5ra. SPEC. O .J. NE I8RIMWI DEPTH FROM THE NOSHED GRADE 10 THE PIPE INERT SHALL BE 5' FRAME AND CRATE MAY BE INSTALLED WAR/ FLANGE DOWN OR CAST NID ADNSTMENT SECTION. 5. MC PRECAST BASE SECTION MAY /1040 ROUNDED FLOOR AND THE WALLS MAY BE SLOPED RATE OF :24 OR 51EEPER. 6. OPENING SHALL BE MEASURED AT THE TOP OF NNE PRECAST BASE SECTION PIPE ALLOWANCES DIAMETER II W 11- N =1I1= II= III =1I1 =III III =III=III= it n MATER MARV 9 HA1AE BKx1u. COMPACT FO 900 OF MODYICD h PROCTOR DENSITY 11 II 11 PPE BENDING PER WSODT /.PIRA w l6 CONSTRUCT TRENCH AND INSTALL PPE PER *5001/ APWA 7 INS F /NOME 8401FlLL IS LESS DM 2 PELT Maw M L RONONAYS MEN ENCASE PIPE N 1- CLASS "C" CONC. TO WE SOME 1'� OMDNSKIVS SHORN FOR PPE REDOING e• n ELEVATION VIEW 8500 24 0. I T= S.6 2.24 lade" OACR17OW CLEW. 6451' NSTAU. N RIME OR a CATCH BASIN —OUTLET ELEVATION- 44.31' I.90" CONTROL RELEASE UNIT (CRU) DETAIL NOT TO SCALE Underground Utilities Location Services Call: TOLL FREE 1- 800 424 -5555 NOT LE33 TN TWO BUSINESS OATS BEFORE 01001N0 CONTROL RELEASE UNIT (CRU) ASSEMBLY DETAIL NOT TO SCALE 84.51 PLAN NEW 044145 11/00/7460 c 4 n u 0 C ec IN O 1 44 Q N I ll tyi Q h ct 0 c 1 V W APPENDICES SITE CHARACTERISTICS AND INFORMATION Parcel Lookup Page 1 of 1 Parcel Number 0630005138400000 Site Address. 9999 E FRONT ST PA Quit Back Taxpayer 801 E FRONT LLC Title Owner 801 E FRONT LLC Description SMITH NORMAN R LOTS 10 -12 BL 38 2/3 -1/3 INT C/O JAMES M COOPER 217 MARITIME DR PORT ANGELES WA 98362 C/O JAMES M COOPER 217 MARITIME DR PORT ANGELES WA 98362 Value Summary Note Listed values do not reflect adjustments made for exemption programs such as Senior /Disabled or Current Use programs (except Commercial Forestland properties) Land Value 192 500 Improvements Value 80 925 Total Assessed Value 273 425 Property Characteristics 4» Note Use Code is for Assessor's purposes only Contact the appropriate planning or building departments for Zoning and allowable usage of propeity Use Code 6511 PHYSICIANS' Land Size (acreage) 00 Note Acreage is not listed for all properties in the Assessor's records More information about land size Tax Status Taxable Tax Code Area. 0010 Zoning Code P_CA Note Zoning and zoning codes change constantly Verify all zoning with the appropriate planning or building department. Building Characteristics. (Click on Bldg for more details Bldg. Type Bldg. Style Total S.F BD BA 01 One Story 1488 Tax History Sales History Quit Back 11901 94811 http.// apps.clallam.net/website /sitts.p pgm ?PARCEL 0630005138400000 6/1n /'1(1(16 O O 1 Map" rayided by Clallarn Cauniy DC D DRAINAGE CALCULATIONS Clallam County Area Washington 205 TABLE 15 WATER lEATURES Flooding' and water table' and terms such as rare brief apparent and perched are explained in the text The symbol means lees than means more than Absence of an entry indicates that the feature is not a concern] Flooding lllh water table** Soil name and Hydrologic map symbol group Frequency Duration Months Depth Kind Months Ft 1 C None 2 0 -4 0 Perched Jan -Mar Agnew 2 B None >6 0 Andeptic Udorthents 3* Beaches 4 D None 0 -1 0 Perched Nov -Jun Bellingham 5 B None >6 0 Calawah 6 A Rare >6 0 Carlsborg 7* Carlsborg A Rare >6 0 Dungeness B Rare >6 0 D None 2 0 -4 0 Perched Dec -Apr isey 9 C None 3 0 -4 0 Perched Jan -Mar Cassolary 10 D None 0 5 -1 5 Perched Jan -May Catla 11* Catla D None 0 5 -1 5 Perched Jan -May Hoypus A None >6 0 12 13 C None 1 5 -3 0 Perched Jan -Apr Clallam 14* Clallam C None 1 5 -3 0 Perched Jan -Apr Hoypus A None >6 0 15 C None 2 5 -3 5 Perched Jan -Mar Clallam Variant 16 A None >6 0 Dick 17 B Rare >6 0 Dungeness 18 19 B None >6 0 Dystric Xerorthents 20, 21 C None 1 5 -3 0 Perched Jan -Apr Elwha See footnotes at end of table F 9 00 Soil Survey Soil name and Ikipth Clay Permeability map symbol 1 Agnew 4 7 3" Beaches 2 Andeptic Udorthents Bellingham 5 Calawah Carlsborg Carlsbor 8 Ca,ey Cassolary symbol mr•rnz le than melt. rnor than I -.n to I. a under I'.ro•rlon t'ac tors -'1' apply to the entlrr, prnt'I.I.r• 1.ntri kind r Or•g•inlc matter apply only to the •not•a c Layer Abacncc of an entry lndicatea Chat d iLa wr r not ava1,lab1 or were not oat.i.niated] L In Pct: In hr 0 -8 15 -25 8 -46 20 -35 46 -60 15 -30 0 -7 7 -60 See t'ootnotr at erid of table TABU 14 -PH? IA Al AND r ;Itl M ICAl I'ItOI'Ii.11'1'I h OP 3011 o 2 -0 6 O 2 -0 6 0 06 -0 2 O 6 -2 0 2 0 -6 0 Available Soil Shrink- weLl wat r capacity reaction potential In/ in O 15 -0 18 O 06 -0 09 O 18 -0 21 5 6 -6 5 Low O 17 -0 20 5 6 -6 5 Moderate O 17 -0 20 5 6 -7 3 Low 4 5 -5 5 Low 4 5 -6 0 Low 0 -9 27 -40 0 06 -0 2 0 20 -0 24 5 6 -6 5 High 9 -60 35 -60 0 06-0 2 0 20 -0 24 6 1 -7 3 High 0 2 2 0 6 0 0 08 10 6 1 6 5 Low 9 -20 2 -4 6 0-20 0 02 -0 04 6 1 5 Low 20 -60 0 -3 6 0 -20 0 01 -0 03 6 1 -7 3 Low 0 -8 5 -10 0 6 -2 0 0 12 -0 15 5 1 -6 5 Low 8 -22 5 -10 0 6 -2 0 0 13 -0 17 5 6-6 5 Low 22 -60 10 -20 0 2 -0 6 0 14 -0 18 5 6 -7 3 Low 10 0 -3 5 -10 0 6 -2 0 0 08 -0 10 5 1 -6 0 Low Catla 3 -14 5 -15 0 6 -2 0 0 08 10 5 1 -6 o Low 14 11* Catla 0 -3 5 -10 0.6 -2 0 0 08 -0 10 5 1 -6 0 Low 3 -14 5 -15 0 6 -2 0 0 08 -0 10 5 1 -6 0 Low 14 lloypu.> 0 2 -5 6 0 -20 0 03 -0 05 5 1 -6 0 Low 4 -15 5 6 0 0 05 -0 08 5 6 -6 5 Low 15 -60 0 -3 6 0 -20 0 01 -0 03 5 6 -6 5 Low 1 13 0 -10 3 -8 0 6 -2 0 0 08 -0 11 5 1 -6 5 Low Clallam 10 -28 3 -12 0 6 -2 0 0 06 10 5 1 5 Low 28 14* Clallam 0 10 3 0 6 -2 0 0 08 -0 11 5 1 -6 5 Low 10 -28 3 -12 0 6 -2 0 0 06 -0 10 5 1-6 5 Low 28 Era alon factors 2' Organic matter Pct O 37 5 3 -5 O 32 O 32 O 20 3 5 -10 O 15 O 32 5 10 -15 O 24 0 -10 0 6 -2 0 0 18-0 21 4 5 5 Low 0 28 5 10 -15 10 -46 0 6 -2 0 0 18 -0 21 4 S -5 5 L.ow 0 28 46 -60 0 6 -2 0 0 11 -0 15 1 5 -5 5 Low 0 24 O 15 2 1 -4 O 10 O 05 0 -9 2 -5 2 0 -6 0 0 08 -0 10 6 1 5 Low 0 15 2 1 -4 9 -20 2 -4 6 0 -20 0 02 -0 04 6 1 -6 5°1 0 10 20 -60 0 -3 6 0 -20 0 01 -0 03 6 1 -7 3 Low 0 05 ,ene 0 -8 5 -15 0 6 -2 0 0 18 -0 20 6 1 -7 3 Low 0 43 5 2 -5 8 -42 5 -15 0 6 -2 0 0 15 -0 17 6 1 -7 3 Low 0 37 42 -60 0 -10 0 6 -2 0 0 06 -0 10 6 6 -7 3 Low 0 24 0 -8 30 -40 0 2 6 0 14 -0 17 5 1 -6 5 Moderate 0 32 3 5 8 -36 35 -55 <0 06 0 13 -0 17 5 6 -7 3 Moderate 0 28 36 -60 35 -55 <0 06 0 13 -0 17 6 1 -7 3 Moderate 0 28 O 24 5 1 -3 O 37 O 20 O 20 1 2 -5 O 20 O 20 1 2 -5 O 20 O 15 3 1 -3 O 05 O 05 O 10 2 3 -5 O 15 O 10 2 3 -5 O 15 6 mo 2 yr 10 yr 25 yr Preconstruction Post Construction 100 yr Basin ID 100y Basin ID 100y+ Ap 0 CN= B'(= Ap 0 i 2,3 Ai= Ot 1,36 CN= 75,E1Z. Ai= O.`tS, Rain '140 Rain 4-,60 Tnp 3C f Tnp 3, 4 S Tni S /4 i Tni rf,. n Other: Basin ID 6m Ap 34& Ai= 0,13k, Rain I 3 Tnp 35,05 Tni S ov�1y Basin ID 2y Ap= Ci 346 Ai G, 136 Rain 240 Tnp =3S 7S Tni Basin ID 10y Ap =0 34b Ai= 0113' Rain 3,2S Tnp =35,6 Tni S Basin ID 25y Ap =O 34 Ai 0(13 Rain 3 7S Tnp 35 b75 Tni s Type 1A Storm SBUH method G' \GEN \t30t31Storm tabie.wpd Basin ID 6m+ CN= B Ap 0 023 CN= CN= 9S.412_ Ai (AS, CN Rain I(31 Tnp 3S 6 75 Tni SJ► vt Basin ID 2y+ Ap O 62,3 CN= S� CN= %,4IZ Ai 0/152 CN =ca Rain Z Tnp 3S, 6,75 Tni 5 y eft, Basin ID =10y+ CN= Ap =C,623 CN= CN= 9S.,4 I Z Ai 0 45 CN= Rain 3 ZS" Tnp 35 6 75 Tn i7.rr <,r Basin ID 25y+ CN Ap CN= 75,4J: Ai Q,` S Rain 7S Tnp 3 5 675 Tni S ;i1 CN= CN= CN= CN= g,& 0 i o' r ss C Pe" ShwllO1 G &id p Sizes of 24 -hour design storms for selected locations in the Puget Sound Basin Rainfall in inches LOCATION 6 Month 2 Year 10 Year 25 Year 100 Year Event Event Event Event Event Port Angeles 1 34 2 10 3 25 3 75 4 60 Sequim 0 99 1 55 2 45 2 95 3 25 Forks 3 19 5 00 7 00 10 00 11 00 Port Townsend 0 70 1 10 1 75 2 00 2 40 Port Hadlock I 0 89 I 1 40 I 2 20 2 60 I 3 00 Source NOAA Precipitation Atlas (Received NTI on 4/13/93) G\GEN\BOBIMISC124 hour rainfall in inches wpd STORMWATER MANAGEMENT MANUAL FOR THE PUGET SOUND BASIN Table III -1 3 SCS Western Washington Runoff Curve Numbers (Published by SCS in 1982) Runoff curve numbers for selected agricultural suburban and urban land use for Type lA rainfall distribution, 24 -hour storm duration Cultivated land(1) Mountain open areas Meadow or pasture Wood or forest land Wood or forest land Orchard LAND USE DESCRIPTION winter condition low growing brush grasslands undisturbed young second growth or brush with cover crop Open spaces, lawns, parks, golf courses, cemeteries, landscaping Good condition Fair condition grass cover on t75% of the area grass cover on 50 -75% of the area Gravel roads parking lots Dirt roads parking lots Impervious surfaces, pavement, roofs etc Open water bodies Single family residential(2) Dwelling Unit /Gross Acre 1 0 DU /GA 1 5 DU /GA 2 0 DU /GA 2 5 DU /GA 3 0 DU /GA 3 5 DU /GA 4 0 DU /GA 4 5 DU /GA 5 0 DU /GA 5 5 DU /GA 6 0 DU /GA 6 5 DU /GA 7 0 DU /GA PUD s, condos, apartments, commercial businesses industrial areas lakes, wetlands, ponds etc %Impervious(3) 15 20 25 30 34 38 42 46 48 50 52 54 56 %impervious must be computed CURVE NUMBERS BY HYDROLOGIC SOIL GROUP A B C D 86 91 94 95 74 82 89 92 65 78 85 89 42 64 76 81 55 72 81 86 81 88 92 94 68 80 86 90 77 85 90 92 76 85 89 91 72 82 87 89 98 98 98 98 100 100 100 100 Separate curve number shall be selected for pervious impervious portions of the site or basin (1) For a more detailed description of agricultural land use curve numbers refer to National Engineering Handbook, Sec 4, Hydrology, Chapter 9, August 1972 (2) Assumes roof and driveway runoff is directed into street /storm system (3) The remaining pervious areas (lawn) are considered to be in good condition for these curve numbers III -1 -12 FEBRUARY, 1992 e "<aA .716, :4e P 6/23/0 10 39 56 am Shareware Release Commercial Bldg at First Front Sts for Lindberg /Smith Architects BASIN ID 100y SBUH METHODOLOGY TOTAL AREA RAINFALL TYPE PRECIPITATION TIME INTERVAL BASIN ID 100y+ SBUH METHODOLOGY TOTAL AREA RAINFALL TYPE PRECIPITATION TIME INTERVAL BASIN ID lOy SBUH METHODOLOGY TOTAL AREA RAINFALL TYPE PRECIPITATION TIME INTERVAL BASIN ID 10y+ SBUH METHODOLOGY TOTAL AREA RAINFALL TYPE PRECIPITATION TIME INTERVAL NAME 100 yr pre 0 62 Acres TYPE1A 4 60 inches 10 00 min ABSTRACTION COEFF 0 20 TcReach Sheet L 100 00 ns 0 4100 p2yr 2 10 s 0 0100 PEAK RATE 0 36 cfs VOL 0 17 Ac -ft TIME 480 min NAME 100 yr post 0 48 Acres TYPE1A 4 60 inches 10 00 min BASIN SUMMARY NAME 10 yr pre NAME 10 yr post page 1 BASEFLOWS 0 00 cfs PERV IMP AREA 0 48 Acres 0 14 Acres CN 86 00 95 42 TC 35 68 min 5 00 min BASEFLOWS 0 00 cfs PERV IMP AREA 0 02 Acres 0 46 Acres CN 86 00 98 00 TC 35 68 min 5 00 min ABSTRACTION COEFF 0 20 TcReach Sheet L 100 00 ns 0 4100 p2yr 2 10 s 0 0100 PEAK RATE 0 45 cfs VOL 0 17 Ac -ft TIME 480 min 0 62 Acres BASEFLOWS 0 00 cfs TYPE1A PERV IMP 3 25 inches AREA 0 48 Acres 0 14 Acres 10 00 min CN 86 00 95 42 TC 35 68 min 5 00 min ABSTRACTION COEFF 0 20 TcReach Sheet L 100 00 ns 0 4100 p2yr 2 10 s 0 0100 PEAK RATE 0 22 cfs VOL 0 11 Ac -ft TIME 480 min 0 48 Acres BASEFLOWS 0 00 cfs TYPE1A PERV IMP 3 25 inches AREA 0 02 Acres 0 46 Acres 10 00 min CN 86 00 98 00 TC 35 68 min 5 00 min ABSTRACTION COEFF 0 20 TcReach Sheet L 100 00 ns 0 4100 p2yr 2 10 s 0 0100 PEAK RATE 0 32 cfs VOL 0 12 Ac -ft TIME 480 min 6/23/06 10 39 56 am Shareware Release Commercial Bldg at First Front Sts for Lindberg /Smith Architects BASIN ID 25y SBUH METHODOLOGY TOTAL AREA RAINFALL TYPE PRECIPITATION TIME INTERVAL BASIN ID 25y+ SBUH METHODOLOGY TOTAL AREA RAINFALL TYPE PRECIPITATION TIME INTERVAL BASIN ID 2y SBUH METHODOLOGY TOTAL AREA RAINFALL TYPE PRECIPITATION TIME INTERVAL ABSTRACTION COEFF TcReach Sheet PEAK RATE 0 11 BASIN ID 2y+ SBUH METHODOLOGY TOTAL AREA RAINFALL TYPE PRECIPITATION TIME INTERVAL ABSTRACTION COEFF TcReach Sheet PEAK RATE 0 20 NAME 25 yr pre 0 62 Acres BASEFLOWS 0 00 cfs TYPE1A PERV 3 75 inches AREA 0 48 Acres 10 00 min CN 86 00 TC 35 68 min ABSTRACTION COEFF 0 20 TcReach Sheet L 100 00 ns 0 4100 p2yr 2 10 s 0 0100 PEAK RATE 0 27 cfs VOL 0 13 Ac -ft TIME 480 min NAME 25 yr post 0 48 Acres BASEFLOWS 0 00 cfs TYPE1A PERV 3 75 inches AREA 0 02 Acres 10 00 min CN 86 00 TC 35 68 min ABSTRACTION COEFF 0 20 TcReach Sheet L 100 00 ns 0 4100 p2yr 2 10 s 0 0100 PEAK RATE 0 37 cfs VOL 0 14 Ac -ft TIME 480 min NAME 2 yr pre 0 62 Acres TYPE1A 2 10 inches 10 00 min 0 20 L 100 00 ns 0 cfs VOL 0 0 TYPE1A 2 10 inches 10 00 min BASIN SUMMARY BASEFLOWS 0 00 cfs PERV AREA 0 48 Acres CN 86 00 TC 35 68 min 4100 p2yr 2 10 s 0 0100 6 Ac -ft TIME 480 min NAME 2 yr post 0 48 Acres BASEFLOWS 0 00 cfs AREA CN TC PERV 0 02 Acres 86 00 35 68 min 0 20 L 100 00 ns 0 4100 p2yr 2 10 s 0 0100 cfs VOL 0 07 Ac -ft TIME 480 min page 2 IMP 0 14 Acres 95 42 5 00 min IMP 0 46 Acres 98 00 5 00 min IMP 0 14 Acres 95 42 5 00 min IMP 0 46 Acres 98 00 5 00 min 6/23/06 10 39 56 am Shareware Release Commercial Bldg at First Front Sts for Lindberg /Smith Architects BASIN ID 6m SBUH METHODOLOGY TOTAL AREA RAINFALL TYPE PRECIPITATION TIME INTERVAL BASIN ID 6m+ SBUH METHODOLOGY TOTAL AREA RAINFALL TYPE PRECIPITATION TIME INTERVAL ABSTRACTION COEFF TcReach Sheet PEAK RATE 0 12 BASIN SUMMARY NAME 6 mo pre 0 62 Acres BASEFLOWS 0 00 cfs TYPE1A PERV IMP 1 34 inches AREA 0 48 Acres 0 14 Acres 10 00 min CN 86 00 95 42 TC 35 68 min 5 00 min ABSTRACTION COEFF 0 20 TcReach Sheet L 100 00 ns 0 4100 p2yr 2 10 s 0 0100 PEAK RATE 0 04 cfs VOL 0 03 Ac -ft TIME 480 min NAME 6 mo post 0 48 Acres BASEFLOWS 0 00 cfs TYPE1A PERV IMP 1 34 inches AREA 0 02 Acres 0 46 Acres 10 00 min CN 86 00 98 00 TC 35 68 min 5 00 min 0 20 L 100 00 ns 0 4100 p2yr 2 10 s 0 0100 cfs VOL 0 04 Ac -ft TIME 480 min page 3 6/23/06 10 39 56 am Shareware Release Commercial Bldg at First Front Sts for Lindberg /Smith Architects HYDROGRAPH SUMMARY PEAK TIME VOLUME HYD RUNOFF OF OF Contrib NUM RATE PEAK HYDRO Area cfs min cf \AcFt Acres 1 0 044 480 1125 cf 0 62 2 0 108 480 2417 cf 0 62 3 0 219 480 4638 cf 0 62 4 0 270 480 5655 cf 0 62 5 0 359 480 7425 cf 0 62 6 0 120 480 1903 cf 0 48 7 0 198 480 3199 cf 0 48 8 0 316 480 5184 cf 0 48 9 0 367 480 6052 cf 0 48 10 0 454 480 7529 cf 0 48 11 0 108 510 3199 cf 0 48 12 0 219 500 5184 cf 0 48 13 0 270 500 6051 cf 0 48 page 4 6/23/06 10 40 1 am Shareware Release Commercial Bldg at First Front Sts for Lindberg /Smith Architects ROUTING REPORT UNDERGROUND PIPE ID No sl Description Storage Pipe Diameter 2 00 ft Length 240 00 ft Slope 0 0050 ft /ft upstr dnstr MULTIPLE ORIFICE ID No dl Description Discharge Orifice Outlet Elev 100 00 Elev 99 90 ft Orifice Diameter 1 8984 in Elev 101 30 ft Orifice 2 Diameter 2 2383 in Elev 101 80 ft Orifice 3 Diameter 1 3594 in page 5 ROUTING CURVE STAGE STORAGE OUTFLOW 0 +2S STAGE STORAGE OUTFLOW 0 +25 STAGE STORAGE OUTFLOW 0 +2S (ft) (cf) (cfs) cfs min (ft) (cf) (cfs) cfs min (ft) (cf) (cfs) cfs min 100 00 0 0000 0 0000 0 0000 101 10 194 75 0 1026 0 7517 102 20 596 91 0 3058 2 2955 100 10 0 5873 0 0309 0 0329 101 20 236 17 0 1071 0 8944 102 30 630 59 0 3197 2 4217 100 20 3 2700 0 0437 0 0546 101 30 266 45 0 1115 0 9997 102 40 660 12 0 3329 2 5333 100 30 8 8650 0 0536 0 0831 101 40 301 49 0 1587 1 1637 102 50 685 40 0 3455 2 6302 100 40 17 892 0 0619 0 1215 101 50 338 75 0 1806 1 3097 102 60 706 43 0 3576 2 7123 100 50 30 709 0 0692 0 1715 101 60 376 99 0 1982 1 4548 102 70 723 29 0 3691 2 7801 100 60 47 561 0 0758 0 2343 101 70 415 23 0 2135 1 5976 102 80 736 10 0 3803 2 8340 100 70 68 595 0 0818 0 3105 101 80 452 49 0 2274 1 7357 102 90 745 13 0 3911 2 8749 100 80 93 879 0 0875 0 4004 101 90 487 53 0 2560 1 8811 103 00 750 72 0 4016 2 9040 100 90 123 40 0 0928 0 5041 102 00 517 82 0 2745 2 0006 103 10 7S3 40 0 4118 2 9231 101 00 157 08 0 0978 0 6214 102 10 559 25 0 2908 2 1549 6/23/06 10 40 1 am Shareware Release Commercial Bldg at First Front Sts for Lindberg /Smith Architects 2yr MATCH Q (cfs) 0 11 PEAK STAGE (ft) 101 21 PEAK TIME 510 00 min INFLOW HYD No 7 LEVEL POOL ROUTING TABLE I1 I2 2S1 0 0000 0 0000 0 0 0000 0 0009 0 0 0009 0 0030 0 0 0030 0 0054 0 O 0054 0 0075 0 0 0075 0 0093 0 0 0093 0 0109 0 0 0109 0 0133 0 0 0133 0 0160 0 O 0160 0 0175 0 0 0175 0 0187 0 0 0187 0 0200 0 0 0200 0 0210 0 O 0210 0 0217 0 0 0217 0 0228 0 0 0228 0 0235 0 0 0235 0 0240 0 O 0240 0 0248 0 0 0248 0 0254 0 O 0254 0 0277 0 0 0277 0 0300 0 O 0300 0 0306 0 0 0306 0 0313 0 0 0313 0 0315 0 O 0315 0 0319 0 O 0319 0 0407 0 0 0407 0 0494 0 0 0494 0 0501 0 0 0501 0 0507 0 O 0507 0 0513 0 0 0513 0 0519 0 O 0519 0 0503 0 0 0503 0 0486 0 0 0486 0 0487 0 0 0487 0 0490 0 O 0490 0 0496 0 0 0496 0 0496 0 0 0496 0 0792 0 0 0792 0 1096 0 0 1096 0 1106 0 0 1106 0 1533 0 0000 0000 0001 0002 0003 0005 0006 0007 0008 0010 0011 0012 0013 0013 0014 0014 0015 0015 0016 0016 0017 0019 0019 0021 0023 0025 0063 0139 0197 0224 0240 0253 0249 0227 0209 0207 0212 0217 0436 1055 1786 LEVEL POOL ROUTING TABLE INFLOW Q (cfs) PEAK OUTFLOW OUTFLOW HYD No 11 SUM 01 cfs min 0 0000 0 0000 0 0009 0 0000 0 0039 0 0008 0 0086 0 0029 0 0132 0 0053 0 0172 0 0074 0 0207 0 0092 0 0249 0 0108 0 0302 0 0132 0 0345 0 0160 0 0373 0 0175 0 0398 0 0186 0 0423 0 0199 0 0441 0 0210 0 0459 0 0217 0 0477 0 0227 0 0490 0 0235 0 0503 0 0240 0 0517 0 0248 O 0546 0 0254 0 0594 0 0275 O 0625 0 0300 0 0638 0 0305 0 0649 0 0311 O 0657 0 0314 0 0751 0 0318 0 0963 0 0371 0 1133 0 0453 0 1205 0 0484 0 1244 0 0498 0 1272 0 0506 0 1274 0 0513 0 1238 0 0511 0 1199 0 0500 0 1186 0 0490 0 1192 0 0489 0 1203 0 0492 0 1505 0 0494 0 2324 0 0575 0 3256 0 0695 0 4425 0 0775 0 20 0 11 02 +2S2 STAGE (ft) page 6 TIME (min) 0 0000 100 00 60 00 O 0009 100 00 70 00 0 0031 100 10 80 00 0 0057 100 10 90 00 O 0079 100 10 100 00 0 0098 100 10 110 00 0 0115 100 10 120 00 0 0141 100 10 130 00 0 0170 100 10 140 00 0 0186 100 10 150 00 O 0198 100 10 160 00 0 0212 100 10 170 00 0 0223 100 10 180 00 0 0231 100 10 190 00 0 0242 100 10 200 00 0 0250 100 10 210 00 O 0255 100 10 220 00 O 0263 100 10 230 00 0 0270 100 10 240 00 0 0293 100 10 250 00 O 0319 100 10 260 00 O 0325 100 10 270 00 0 0332 100 10 280 00 0 0338 100 10 290 00 0 0343 100 10 300 00 0 0434 100 11 310 00 0 0592 100 15 320 00 0 0680 100 22 330 00 0 0721 100 25 340 00 0 0746 100 26 350 00 0 0766 100 27 360 00 0 0761 100 28 370 00 0 0726 100 28 380 00 0 0700 100 26 390 00 0 0696 100 25 400 00 0 0703 100 25 410 00 O 0712 100 26 420 00 0 1011 100 26 430 00 0 1750 100 35 440 00 0 2561 100 51 450 00 0 3650 100 63 460 00 6/23/06 10 40 1 am Shareware Release Commercial Bldg at First Front Sts for Lindberg /Smith Architects LEVEL POOL ROUTING TABLE page 7 LEVEL POOL ROUTING TABLE Il I2 2S1 SUM 01 02 +2S2 STAGE TIME cfs min (ft) (min) 0 1533 0 1966 0 2797 0 6296 0 0853 0 5443 100 76 470 00 O 1966 0 1985 0 4498 0 8449 0 0945 0 7504 100 93 480 00 0 1985 0 1433 0 6478 0 9896 0 1025 0 8871 101 10 490 00 0 1433 0 0872 0 7802 1 0107 0 1069 0 9038 101 19 500 00 0 0872 0 0873 0 7962 0 9707 0 1075 0 8632 101 21 510 00 0 0873 0 0825 0 7570 0 9268 0 1061 0 8206 101 18 520 00 0 0825 0 0780 0 7158 0 8763 0 1048 0 7715 101 15 530 00 0 0780 0 0780 0 6683 0 8243 0 1032 0 7211 101 11 540 00 0 0780 0 0660 0 6196 0 7636 0 1015 0 6622 101 08 550 00 0 0660 0 0540 0 5629 0 6829 0 0993 0 5836 101 03 560 00 0 0540 0 0539 0 4874 0 5953 0 0962 0 4991 100 97 570 00 O 0539 0 0541 0 4066 0 5147 0 0925 0 4221 100 90 580 00 0 0541 0 0538 0 3336 0 4415 0 0886 0 3529 100 82 590 00 0 0538 0 0538 0 2685 0 3761 0 0845 0 2916 100 75 600 00 0 0538 0 0515 0 2113 0 3167 0 0803 0 2363 100 68 610 00 0 0515 0 0492 0 1604 0 2612 0 0759 0 1853 100 60 620 00 0 0492 0 0492 0 1147 0 2131 0 0706 0 1425 100 52 630 00 0 0492 0 0489 0 0776 0 1758 0 0649 0 1109 100 44 640 00 0 0489 0 0492 0 0513 0 1495 0 0596 0 0899 100 37 650 00 0 0492 0 0493 0 0349 0 1334 0 0550 0 0784 100 32 660 00 0 0493 0 0444 0 0264 0 1201 0 0519 0 0681 100 28 670 00 0 0444 0 0395 0 0197 0 1036 0 0484 0 0552 100 25 680 00 0 0395 0 0394 0 0113 0 0902 0 0439 0 0462 100 20 690 00 0 0394 0 0397 0 0074 0 0866 0 0388 0 0478 100 16 700 00 0 0397 0 0394 0 0081 0 0872 0 0397 0 0475 100 17 710 00 0 0394 0 0394 0 0080 0 0868 0 0395 0 0472 100 17 720 00 0 0394 0 0397 0 0079 0 0869 0 0394 0 0476 100 17 730 00 0 0397 0 0394 0 0080 0 0871 0 0396 0 0475 100 17 740 00 O 0394 0 0394 0 0080 0 0868 0 0395 0 0472 100 17 750 00 0 0394 0 0397 0 0079 0 0870 0 0394 0 0476 100 17 760 00 0 0397 0 0394 0 0080 0 0872 0 0396 0 0476 100 17 770 00 O 0394 0 0394 0 0080 0 0869 0 0396 0 0473 100 17 780 00 0 0394 0 0348 0 0079 0 0822 0 0394 0 0427 100 17 790 00 0 0348 0 0299 0 0060 0 0707 0 0367 0 0340 100 15 800 00 O 0299 0 0298 0 0024 0 0621 0 0316 0 0306 100 11 810 00 0 0298 0 0298 0 0018 0 0615 0 0287 0 0327 100 09 820 00 0 0298 0 0298 0 0019 0 0616 0 0308 0 0308 100 10 830 00 0 0298 0 0298 0 0018 0 0614 0 0289 0 0325 100 10 840 00 0 0298 0 0321 0 0019 0 0638 0 0305 0 0333 100 10 850 00 0 0321 0 0347 0 0021 0 0689 0 0312 0 0378 100 10 860 00 0 0347 0 0347 0 0040 0 0734 0 0338 0 0396 100 12 870 00 0 0347 0 0345 0 0047 0 0739 0 0349 0 0391 100 13 880 00 O 0345 0 0348 0 0045 0 0738 0 0346 0 0392 100 13 890 00 0 0348 0 0348 0 0046 0 0741 0 0346 0 0395 100 13 900 00 O 0348 0 0345 0 0047 0 0740 0 0348 0 0392 100 13 910 00 0 0345 0 0348 0 0045 0 0739 0 0346 0 0393 100 13 920 00 0 0348 0 0348 0 0046 0 0743 0 0347 0 0396 100 13 930 00 6/23/06 10 40 1 am Shareware Release Commercial Bldg at First Front Sts for Lindberg /Smith Architects LEVEL POOL ROUTING TABLE _page_ LEVEL POOL ROUTING TABLE I1 I2 2S1 SUM 01 02 +2S2 STAGE TIME cfs min (ft) (min) 0 0348 0 0346 0 0047 0 0741 0 0349 0 0393 100 13 940 00 O 0346 0 0349 0 0046 0 0740 0 0347 0 0393 100 13 950 00 0 0349 0 0349 0 0046 0 0744 0 0347 0 0396 100 13 960 00 0 0349 0 0273 0 0047 0 0670 0 0349 0 0321 100 13 970 00 O 0273 0 0203 0 0019 0 0496 0 0301 0 0194 100 10 980 00 0 0203 0 0202 0 0012 0 0417 0 0183 0 0235 100 10 990 00 0 0202 0 0199 0 0014 0 0415 0 0221 0 0195 100 10 1000 00 0 0199 0 0201 0 0012 0 0412 0 0183 0 0229 100 10 1010 00 0 0201 0 0201 0 0014 0 0416 0 0215 0 0201 100 10 1020 00 0 0201 0 0247 0 0012 0 0460 0 0189 0 0271 100 10 1030 00 0 0247 0 0297 0 0016 0 0561 0 0255 0 0305 100 10 1040 00 0 0297 0 0297 0 0018 0 0613 0 0287 0 0326 100 10 1050 00 0 0297 0 0298 0 0019 0 0615 0 0306 0 0309 100 10 1060 00 0 0298 0 0298 0 0018 0 0614 0 0290 0 0324 100 10 1070 00 0 0298 0 0298 0 0019 0 0616 0 0305 0 0311 100 10 1080 00 0 0298 0 0275 0 0019 0 0592 0 0292 0 0300 100 10 1090 00 0 0275 0 0249 0 0018 0 0542 0 0282 0 0260 100 10 1100 00 0 0249 0 0249 0 0015 0 0513 0 0245 0 0269 100 10 1110 00 0 0249 0 0339 0 0016 0 0604 0 0253 0 0351 100 10 1120 00 0 0339 0 0249 0 0029 0 0617 0 0322 0 0295 100 11 1130 00 O 0249 0 0162 0 0018 0 0429 0 0277 0 0151 100 09 1140 00 0 0162 0 0251 0 0009 0 0422 0 0142 0 0280 100 10 1150 00 0 0251 0 0248 0 0017 0 0516 0 0263 0 0253 100 10 1160 00 0 0248 0 0248 0 0015 0 0512 0 0238 0 0274 100 10 1170 00 0 0248 0 0251 0 0016 0 0516 0 0257 0 0259 100 10 1180 00 0 0251 0 0249 0 0015 0 0515 0 0243 0 0272 100 10 1190 00 O 0249 0 0249 0 0016 0 0513 0 0256 0 0258 100 10 1200 00 O 0249 0 0252 0 0015 0 0515 0 0242 0 0273 100 10 1210 00 O 0252 0 0249 0 0016 0 0517 0 0257 0 0260 100 10 1220 00 0 0249 0 0249 0 0015 0 0513 0 0244 0 0269 100 10 1230 00 0 0249 0 0252 0 0016 0 0516 0 0253 0 0264 100 10 1240 00 O 0252 0 0249 0 0016 0 0516 0 0248 0 0268 100 10 1250 00 0 0249 0 0249 0 0016 0 0514 0 0252 0 0261 100 10 1260 00 0 0249 0 0252 0 0016 0 0516 0 0246 0 0270 100 10 1270 00 0 0252 0 0249 0 0016 0 0517 0 0254 0 0262 100 10 1280 00 0 0249 0 0249 0 0016 0 0513 0 0247 0 0267 100 10 1290 00 0 0249 0 0252 0 0016 0 0517 0 0251 0 0266 100 10 1300 00 0 0252 0 0249 0 0016 0 0517 0 0250 0 0267 100 10 1310 00 0 0249 0 0249 0 0016 0 0514 0 0251 0 0263 100 10 1320 00 0 0249 0 0226 0 0016 0 0490 0 0248 0 0243 100 10 1330 00 0 0226 0 0202 0 0014 0 0442 0 0228 0 0214 100 10 1340 00 0 0202 0 0202 0 0013 0 0417 0 0201 0 0216 100 10 1350 00 0 0202 0 0199 0 0013 0 0414 0 0203 0 0211 100 10 1360 00 0 0199 0 0202 0 0013 0 0413 0 0198 0 0215 100 10 1370 00 0 0202 0 0202 0 0013 0 0416 0 0202 0 0214 100 10 1380 00 0 0202 0 0199 0 0013 0 0413 0 0201 0 0212 100 10 1390 00 0 0199 0 0201 0 0013 0 0413 0 0199 0 0214 100 10 1400 00 6/23/06 10 40 1 am _Shareware Release Commercial Bldg at First Front Sts for Lindberg /Smith Architects LEVEL POOL ROUTING TABLE page _9_ LEVEL POOL ROUTING TABLE I1 I2 2S1 SUM 01 02 +252 STAGE TIME cfs min (ft) (min) 0 0201 0 0201 0 0013 0 0415 0 0201 0 0215 100 10 1410 00 O 0201 0 0198 0 0013 0 0413 0 0202 0 0211 100 10 1420 00 0 0198 0 0201 0 0013 0 0412 0 0198 0 0214 100 10 1430 00 0 0201 0 0201 0 0013 0 0415 0 0201 0 0214 100 10 1440 00 0 0201 0 0102 0 0013 0 0316 0 0201 0 0115 100 10 1450 00 0 0102 0 0005 0 0007 0 0114 0 0108 0 0006 100 10 1460 00 O 0005 0 0004 0 0000 0 0009 0 0006 0 0004 100 10 1470 00 0 0004 0 0003 0 0000 0 0007 0 0003 0 0003 100 10 1480 00 0 0003 0 0002 0 0000 0 0005 0 0003 0 0002 100 10 1490 00 0 0002 0 0002 0 0000 0 0004 0 0002 0 0002 100 10 1500 00 0 0002 0 0001 0 0000 0 0003 0 0002 0 0001 100 10 1510 00 0 0001 0 0001 0 0000 0 0002 0 0001 0 0001 100 10 1520 00 0 0001 0 0001 0 0000 0 0002 0 0001 0 0001 100 10 1530 00 0 0001 0 0001 0 0000 0 0001 0 0001 0 0001 100 10 1540 00 0 0001 0 0000 0 0000 0 0001 0 0001 0 0000 100 10 1550 00 0 0000 0 0000 0 0000 0 0001 0 0000 0 0000 100 10 1560 00 O 0000 0 0000 0 0000 0 0001 0 0000 0 0000 100 10 1570 00 0 0000 0 0000 0 0000 0 0000 0 0000 0 0000 100 10 1580 00 0 0000 0 0000 0 0000 0 0000 0 0000 0 0000 100 10 1590 00 0 0000 0 0000 0 0000 0 0000 0 0000 0 0000 100 10 1600 00 0 0000 0 0000 0 0000 0 0000 0 0000 0 0000 100 10 1610 00 0 0000 0 0000 0 0000 0 0000 0 0000 0 0000 100 10 1620 00 0 0000 0 0000 0 0000 0 0000 0 0000 -0 0000 100 10 1630 00 6/23/06 10 40 2 am Shareware Release Commercial Bldg at First Front Sts for Lindberg /Smith Architects ROUTING REPORT UNDERGROUND PIPE ID No sl Description Storage Pipe Diameter 2 00 ft Length 240 00 ft Slope 0 0050 ft /ft upstr dnstr MULTIPLE ORIFICE ID No dl Description Discharge Orifice Outlet Elev 100 00 Elev 99 90 ft Orifice Diameter 1 8984 in Elev 101 30 ft Orifice 2 Diameter 2 2383 in Elev 101 80 ft Orifice 3 Diameter 1 3594 in page 10 ROUTING CURVE STAGE STORAGE OUTFLOW 0 +2S STAGE STORAGE OUTFLOW 0 +2S STAGE STORAGE OUTFLOW 0 +2S (ft) (cf) (cfs) cfs min (ft) (cf) (cfs) cfs min (ft) (cf) (cfs) cfs min 100 00 0 0000 0 0000 0 0000 101 10 194 75 0 1026 0 7517 102 20 596 91 0 3058 2 2955 100 10 0 5873 0 0309 0 0329 101 20 236 17 0 1071 0 8944 102 30 630 59 0 3197 2 4217 100 20 3 2700 0 0437 0 0546 101 30 266 45 0 1115 0 9997 102 40 660 12 0 3329 2 5333 100 30 8 8650 0 0536 0 0831 101 40 301 49 0 1587 1 1637 102 50 685 40 0 3455 2 6302 100 40 17 892 0 0619 0 1215 101 50 338 75 0 1806 1 3097 102 60 706 43 0 3576 2 7123 100 50 30 709 0 0692 0 1715 101 60 376 99 0 1982 1 4548 102 70 723 29 0 3691 2 7801 100 60 47 561 0 0758 0 2343 101 70 415 23 0 2135 1 5976 102 80 736 10 0 3803 2 8340 100 70 68 595 0 0818 0 3105 101 80 452 49 0 2274 1 7357 102 90 745 13 0 3911 2 8749 100 80 93 879 0 0875 0 4004 101 90 487 53 0 2560 1 8811 103 00 750 72 0 4016 2 9040 100 90 123 40 0 0928 0 5041 102 00 517 82 0 2745 2 0006 103 10 753 40 0 4118 2 9231 101 00 157 08 0 0978 0 6214 102 10 559 25 0 2908 2 1549 6/23/06 10 40 2 am Shareware Release Commercial Bldg at First Front Sts for Lindberg /Smith Architects l0yr MATCH Q (.cfs) 0 22 PEAK STAGE (ft) 101 74 PEAK TIME 500 00 min INFLOW HYD No 8 LEVEL POOL ROUTING TABLE Il I2 2S1 0 0000 0 0000 0 0 0000 0 0012 0 0 0012 0 0035 0 0 0035 0 0081 0 0 0081 0 0136 0 0 0136 0 0174 0 0 0174 0 0205 0 0 0205 0 0232 0 0 0232 0 0255 0 0 0255 0 0297 0 0 0297 0 0342 0 0 0342 0 0361 0 0 0361 0 0374 0 0 0374 0 0391 0 0 0391 0 0403 0 0 0403 0 0410 0 O 0410 0 0423 0 0 0423 0 0431 0 0 0431 0 0435 0 0 0435 0 0445 0 0 0445 0 0451 0 O 0451 0 0489 0 O 0489 0 0526 0 0 0526 0 0532 0 0 0532 0 0541 0 0 0541 0 0542 0 0 0542 0 0547 0 0 0547 0 0692 0 O 0692 0 0835 0 0 0835 0 0843 0 0 0843 0 0849 0 O 0849 0 0856 0 0 0856 0 0861 0 0 0861 0 0832 0 0 0832 0 0801 0 0 0801 0 0800 0 0 0800 0 0803 0 0 0803 0 0811 0 0 0811 0 0809 0 0 0809 0 1285 0 0 1285 0 1770 0 LEVEL POOL ROUTING TABLE INFLOW Q (cfs) PEAK OUTFLOW OUTFLOW HYD No 12 SUM cfs min O 32 O 22 page 11 01 02 +2S2 STAGE TIME (ft) (min) 0000 0 0000 0 0000 0 0000 100 00 40 0000 0 0012 0 0000 0 0012 100 00 50 0001 0 0047 0 0011 0 0037 100 10 60 0002 0 0119 0 0034 0 0084 100 10 70 0005 0 0222 0 0079 0 0143 100 10 80 0008 0 0318 0 0134 0 0184 100 10 90 0011 0 0390 0 0173 0 0217 100 10 100 0013 0 0450 0 0204 0 0246 100 10 110 0015 0 0501 0 0231 0 0270 100 10 120 0016 0 0568 0 0254 0 0314 100 10 130 0019 0 0658 0 0295 0 0363 100 10 140 0034 0 0737 0 0329 0 0408 100 12 150 0052 0 0787 0 0356 0 0432 100 14 160 0062 0 0827 0 0370 0 0458 100 15 170 0072 0 0867 0 0385 0 0482 100 16 180 0083 0 0896 0 0400 0 0497 100 17 190 0089 0 0922 0 0408 0 0514 100 18 200 0096 0 0950 0 0418 0 0532 100 19 210 0103 0 0969 0 0429 0 0540 100 19 220 0107 0 0987 0 0434 0 0553 100 20 230 0113 0 1010 0 0440 0 0570 100 20 240 0125 0 1065 0 0446 0 0619 100 21 250 0157 0 1171 0 0462 0 0709 100 23 260 0215 0 1273 0 0493 0 0780 100 26 270 0262 0 1335 0 0518 0 0817 100 28 280 0286 0 1370 0 0531 0 0839 100 29 290 0301 0 1390 0 0537 0 0853 100 30 300 0313 0 1551 0 0540 0 1011 100 31 310 0436 0 1964 0 0575 0 1389 100 35 320 0745 0 2423 0 0644 0 1779 100 43 330 1081 0 2773 0 0698 0 2074 100 51 340 1345 0 3050 0 0729 0 2321 100 56 350 1566 0 3282 0 0755 0 2527 100 60 360 1755 0 3447 0 0772 0 2675 100 62 370 1891 0 3524 0 0784 0 2740 100 64 380 1951 0 3552 0 0789 0 2763 100 65 390 1972 0 3576 0 0791 0 2785 100 66 400 1992 0 3606 0 0793 0 2813 100 66 410 2018 0 3638 0 0795 0 2843 100 66 420 2045 0 4139 0 0797 0 3342 100 67 430 2509 0 5564 0 0833 0 4731 100 73 440 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 6/23/06 10 40 2 am Shareware Release Commercial Bldg at First Front Sts for Lindberg /Smith Architects page 12 LEVEL POOL ROUTING TABLE LEVEL POOL ROUTING TABLE I1 I2 2S1 SUM 01 O2 +2S2 STAGE TIME cfs min (ft) (min) 0 1770 0 1782 0 3819 0 7372 0 0912 0 6460 100 87 450 00 O 1782 0 2458 0 5473 0 9712 0 0987 0 8725 101 02 460 00 0 2458 0 3140 0 7661 1 3259 0 1064 1 2194 101 18 470 00 0 3140 0 3162 1 0524 1 6825 0 1671 1 5155 101 44 480 00 0 3162 0 2283 1 3108 1 8552 0 2047 1 6506 101 64 490 00 O 2283 0 1393 1 4317 1 7994 0 2188 1 5805 101 74 500 00 O 1393 0 1391 1 3689 1 6472 0 2117 1 4356 101 69 510 00 O 1391 0 1313 1 2397 1 5101 0 1958 1 3142 101 59 520 00 0 1313 0 1240 1 1331 1 3883 0 1811 1 2072 101 50 530 00 0 1240 0 1238 1 0420 1 2898 0 1652 1 1245 101 43 540 00 0 1238 0 1049 0 9771 1 2058 0 1474 1 0583 101 38 550 00 0 1049 0 0858 0 9299 1 1205 0 1284 0 9922 101 34 560 00 O 0858 0 0855 0 8810 1 0522 0 1112 0 9410 101 29 570 00 0 0855 0 0858 0 8320 1 0033 0 1091 0 8942 101 24 580 00 0 0858 0 0852 0 7870 0 9580 0 1071 0 8509 101 20 590 00 0 0852 0 0851 0 7452 0 9155 0 1057 0 8097 101 17 600 00 0 0851 0 0815 0 7053 0 8719 0 1044 0 7674 101 14 610 00 0 0815 0 0778 0 6644 0 8236 0 1031 0 7205 101 11 620 00 0 0778 0 0777 0 6191 0 7746 0 1014 0 6732 101 08 630 00 O 0777 0 0772 0 5735 0 7284 0 0997 0 6287 101 04 640 00 0 0772 0 0777 0 5306 0 6855 0 0981 0 5875 101 01 650 00 0 0777 0 0776 0 4911 0 6464 0 0964 0 5501 100 97 660 00 0 0776 0 0700 0 4553 0 6029 0 0948 0 5082 100 94 670 00 O 0700 0 0622 0 4152 0 5474 0 0930 0 4545 100 90 680 00 0 0622 0 0621 0 3642 0 4886 0 0902 0 3984 100 85 690 00 0 0621 0 0625 0 3110 0 4357 0 0874 0 3484 100 80 700 00 0 0625 0 0620 0 2642 0 3887 0 0842 0 3045 100 74 710 00 0 0620 0 0620 0 2232 0 3472 0 0814 0 2659 100 69 720 00 O 0620 0 0624 0 1876 0 3121 0 0783 0 2338 100 64 730 00 O 0624 0 0620 0 1581 0 2825 0 0757 0 2068 100 60 740 00 0 0620 0 0620 0 1339 0 2579 0 0729 0 1850 100 56 750 00 O 0620 0 0624 0 1145 0 2389 0 0706 0 1683 100 52 760 00 O 0624 0 0620 0 0996 0 2240 0 0687 0 1553 100 49 770 00 0 0620 0 0620 0 0885 0 2125 0 0668 0 1457 100 47 780 00 0 0620 0 0548 0 0803 0 1971 0 0654 0 1317 100 45 790 00 0 0548 0 0470 0 0684 0 1701 0 0633 0 1068 100 42 800 00 0 0470 0 0469 0 0481 0 1421 0 0587 0 0834 100 36 810 00 0 0469 0 0469 0 0297 0 1235 0 0536 0 0699 100 30 820 00 0 0469 0 0468 0 0209 0 1146 0 0490 0 0656 100 25 830 00 0 0468 0 0468 0 0181 0 1116 0 0475 0 0641 100 24 840 00 0 0468 0 0504 0 0171 0 1143 0 0470 0 0673 100 23 850 00 0 0504 0 0545 0 0192 0 1240 0 0481 0 0759 100 24 860 00 0 0545 0 0545 0 0248 0 1338 0 0511 0 0827 100 27 870 00 0 0545 0 0541 0 0293 0 1379 0 0534 0 0844 100 30 880 00 O 0541 0 0546 0 0306 0 1392 0 0539 0 0854 100 30 890 00 0 0546 0 0546 0 0313 0 1405 0 0541 0 0864 100 31 900 00 0 0546 0 0542 0 0321 0 1409 0 0543 0 0866 100 31 910 00 6/23/06 10 40 2 am Shareware Release Commercial Bldg at First Front Sts for Lindberg /Smith Architects LEVEL POOL ROUTING TABLE page 13 LEVEL POOL ROUTING TABLE I1 I2 2S1 SUM 01 02 +2S2 STAGE TIME cfs min (ft) (min) 0 0542 0 0546 0 0323 0 1411 0 0543 0 0867 100 31 920 00 0 0546 0 0546 0 0324 0 1416 0 0543 0 0873 100 31 930 00 0 0546 0 0542 0 0328 0 1417 0 0545 0 0872 100 31 940 00 0 0542 0 0547 0 0327 0 1416 0 0544 0 0872 100 31 950 00 0 0547 0 0547 0 0327 0 1420 0 0544 0 0876 100 31 960 00 0 0547 0 0429 0 0331 0 1306 0 0545 0 0761 100 31 970 00 0 0429 0 0319 0 0250 0 0998 0 0511 0 0486 100 28 980 00 0 0319 0 0318 0 0084 0 0721 0 0402 0 0319 100 17 990 00 0 0318 0 0312 0 0019 0 0649 0 0300 0 0349 100 10 1000 00 0 0312 0 0316 0 0028 0 0656 0 0321 0 0335 100 11 1010 00 0 0316 0 0315 0 0022 0 0653 0 0313 0 0340 100 10 1020 00 0 0315 0 0387 0 0024 0 0727 0 0316 0 0411 100 11 1030 00 0 0387 0 0465 0 0053 0 0906 0 0358 0 0548 100 14 1040 00 0 0465 0 0466 0 0110 0 1040 0 0438 0 0602 100 20 1050 00 0 0466 0 0466 0 0146 0 1077 0 0457 0 0621 100 22 1060 00 0 0466 0 0467 0 0158 0 1091 0 0463 0 0627 100 23 1070 00 0 0467 0 0467 0 0162 0 1096 0 0465 0 0630 100 23 1080 00 0 0467 0 0431 0 0164 0 1062 0 0466 0 0596 100 23 1090 00 0 0431 0 0390 0 0141 0 0962 0 0454 0 0508 100 22 1100 00 0 0390 0 0390 0 0093 0 0873 0 0415 0 0458 100 18 1110 00 0 0390 0 0530 0 0073 0 0993 0 0386 0 0607 100 16 1120 00 0 0530 0 0390 0 0149 0 1070 0 0458 0 0611 100 22 1130 00 0 0390 0 0254 0 0151 0 0796 0 0460 0 0336 100 22 1140 00 0 0254 0 0393 0 0022 0 0670 0 0313 0 0356 100 10 1150 00 0 0393 0 0389 0 0031 0 0813 0 0325 0 0487 100 11 1160 00 0 0389 0 0389 0 0085 0 0862 0 0403 0 0460 100 17 1170 00 0 0389 0 0393 0 0073 0 0855 0 0386 0 0469 100 16 1180 00 0 0393 0 0389 0 0077 0 0859 0 0392 0 0468 100 16 1190 00 0 0389 0 0389 0 0077 0 0854 0 0391 0 0463 100 16 1200 00 0 0389 0 0393 0 0075 0 0857 0 0389 0 0469 100 16 1210 00 0 0393 0 0389 0 0077 0 0860 0 0392 0 0468 100 16 1220 00 0 0389 0 0389 0 0077 0 0855 0 0391 0 0464 100 16 1230 00 0 0389 0 0394 0 0075 0 0858 0 0389 0 0469 100 16 1240 00 0 0394 0 0389 0 0077 0 0860 0 0392 0 0468 100 16 1250 00 0 0389 0 0389 0 0077 0 0855 0 0391 0 0464 100 16 1260 00 0 0389 0 0394 0 0075 0 0858 0 0389 0 0469 100 16 1270 00 0 0394 0 0389 0 0077 0 0860 0 0392 0 0468 100 16 1280 00 0 0389 0 0389 0 0077 0 0855 0 0391 0 0464 100 16 1290 00 0 0389 0 0394 0 0075 0 0858 0 0389 0 0469 100 16 1300 00 0 0394 0 0389 0 0077 0 0860 0 0392 0 0468 100 16 1310 00 0 0389 0 0389 0 0077 0 0855 0 0391 0 0464 100 16 1320 00 0 0389 0 0353 0 0075 0 0817 0 0389 0 0428 100 16 1330 00 0 0353 0 0316 0 0061 0 0730 0 0368 0 0362 100 15 1340 00 0 0316 0 0316 0 0033 0 0665 0 0329 0 0337 100 12 1350 00 0 0316 0 0311 0 0023 0 0650 0 0314 0 0336 100 10 1360 00 0 0311 0 0315 0 0022 0 0648 0 0313 0 0335 100 10 1370 00 0 0315 0 0315 0 0022 0 0652 0 0313 0 0339 100 10 1380 00 6/23/06 10 40 2 am Shareware Release Commercial Bldg at First Front Sts for Lindberg /Smith Architects LEVEL POOL ROUTING TABLE page 14 LEVEL POOL ROUTING TABLE Il I2 2S1 SUM 01 02 +2S2 STAGE TIME cfs min (ft) (min) 0 0315 0 0310 0 0024 0 0649 0 0315 0 0334 100 10 1390 00 0 0310 0 0315 0 0022 0 0647 0 0312 0 0334 100 10 1400 00 0 0315 0 0315 0 0022 0 0651 0 0313 0 0339 100 10 1410 00 0 0315 0 0310 0 0024 0 0648 0 0315 0 0333 100 10 1420 00 0 0310 0 0315 0 0021 0 0646 0 0312 0 0334 100 10 1430 00 0 0315 0 0315 0 0022 0 0651 0 0312 0 0338 100 10 1440 00 0 0315 0 0160 0 0023 0 0498 0 0315 0 0183 100 10 1450 00 0 0160 0 0009 0 0011 0 0180 0 0172 0 0007 100 06 1460 00 0 0009 0 0007 0 0000 0 0016 0 0007 0 0009 100 10 1470 00 0 0007 0 0005 0 0001 0 0012 0 0008 0 0004 100 10 1480 00 0 0005 0 0004 0 0000 0 0009 0 0004 0 0005 100 10 1490 00 0 0004 0 0003 0 0000 0 0007 0 0005 0 0002 100 10 1500 00 0 0003 0 0002 0 0000 0 0005 0 0002 0 0003 100 10 1510 00 0 0002 0 0002 0 0000 0 0004 0 0003 0 0001 100 10 1520 00 0 0002 0 0001 0 0000 0 0003 0 0001 0 0002 100 10 1530 00 0 0001 0 0001 0 0000 0 0002 0 0002 0 0000 100 10 1540 00 0 0001 0 0001 0 0000 0 0002 0 0000 0 0001 100 10 1550 00 0 0001 0 0001 0 0000 0 0001 0 0001 0 0000 100 10 1560 00 0 0001 0 0000 0 0000 0 0001 0 0000 0 0001 100 10 1570 00 0 0000 0 0000 0 0000 0 0001 0 0001 -0 0000 100 10 1580 00 6/23/06 10 40 3 am Shareware Release Commercial Bldg at First Front Sts for Lindberg /Smith Architects ROUTING REPORT UNDERGROUND PIPE ID No sl Description Storage Pipe Diameter 2 00 ft Length 240 00 ft Slope 0 0050 ft /ft upstr dnstr MULTIPLE ORIFICE ID No dl Description Discharge Orifice Outlet Elev 100 00 Elev 99 90 ft Orifice Diameter 1 8984 in Elev 101 30 ft Orifice 2 Diameter 2 2383 in Elev 101 80 ft Orifice 3 Diameter 1 3594 in page 15 ROUTING CURVE STAGE STORAGE OUTFLOW 0 +25 STAGE STORAGE OUTFLOW 0 +2S STAGE STORAGE OUTFLOW 0 +2S (ft) (cf) (cfs) cfs min (ft) (cf) (cfs) cfs min (ft) (cf) (cfs) cfs min 100 00 0 0000 0 0000 0 0000 101 10 194 75 0 1026 0 7517 102 20 596 91 0 3058 2 2955 100 10 0 5873 0 0309 0 0329 101 20 236 17 0 1071 0 8944 102 30 630 59 0 3197 2 4217 100 20 3 2700 0 0437 0 0546 101 30 266 45 0 1115 0 9997 102 40 660 12 0 3329 2 5333 100 30 8 8650 0 0536 0 0831 101 40 301 49 0 1587 1 1637 102 50 685 40 0 3455 2 6302 100 40 17 892 0 0619 0 1215 101 50 338 75 0 1806 1 3097 102 60 706 43 0 3576 2 7123 100 50 30 709 0 0692 0 1715 101 60 376 99 0 1982 1 4548 102 70 723 29 0 3691 2 7801 100 60 47 561 0 0758 0 2343 101 70 415 23 0 2135 1 5976 102 80 736 10 0 3803 2 8340 100 70 68 595 0 0818 0 3105 101 80 452 49 0 2274 1 7357 102 90 745 13 0 3911 2 8749 100 80 93 879 0 0875 0 4004 101 90 487 53 0 2560 1 8811 103 00 750 72 0 4016 2 9040 100 90 123 40 0 0928 0 5041 102 00 517 82 0 2745 2 0006 103 10 753 40 0 4118 2 9231 101 00 157 08 0 0978 0 6214 102 10 559 25 0 2908 2 1549 6/23/06 10 40 3 am Shareware Release Commercial Bldg at First Front Sts for Lindberg /Smith Architects 25yr MATCH Q (cfs) 0 27 PEAK STAGE (ft) 101 98 PEAK TIME 500 00 min INFLOW HYD No 9 LEVEL POOL ROUTING TABLE I1 I2 2S1 O 0000 0 0005 0 0000 0 0005 0 0029 0 0000 0 0029 0 0063 0 0002 0 0063 0 0122 0 0004 0 0122 0 0191 0 0008 0 0191 0 0234 0 0012 0 0234 0 0270 0 0015 0 0270 0 0299 0 0017 0 0299 0 0323 0 0019 0 0323 0 0373 0 0025 0 0373 0 0426 0 0051 0 0426 0 0446 0 0088 0 0446 0 0459 0 0113 0 0459 0 0477 0 0129 0 0477 0 0489 0 0155 0 0489 0 0496 0 0183 0 0496 0 0509 0 0204 O 0509 0 0518 0 0223 0 0518 0 0521 0 0244 0 0521 0 0532 0 0258 0 0532 0 0538 0 0272 O 0538 0 0582 0 0288 O 0582 0 0625 0 0331 0 0625 0 0631 0 0421 0 0631 0 0641 0 0512 0 0641 0 0641 0 0576 0 0641 0 0646 0 0622 0 0646 0 0816 0 0657 0 0816 0 0983 0 0831 0 0983 0 0991 0 1253 0 0991 0 0998 0 1738 0 0998 0 1004 0 2149 0 1004 0 1009 0 2511 0 1009 0 0974 0 2836 O 0974 0 0938 0 3092 0 0938 0 0936 0 3250 0 0936 0 0939 0 3356 0 0939 0 0947 0 3452 0 0947 0 0945 0 3549 0 0945 0 1498 0 3641 0 1498 0 2062 0 4248 LEVEL POOL ROUTING TABLE INFLOW Q (cfs) PEAK OUTFLOW OUTFLOW HYD No 13 SUM cfs min 0 0005 O 0035 0 0094 0 0189 0 0320 0 0437 0 0519 0 0586 O 0641 0 0722 0 0849 O 0960 0 1017 0 1065 O 1121 0 1167 0 1209 O 1250 0 1283 0 1311 0 1342 0 1408 0 1537 O 1677 0 1784 0 1858 0 1909 0 2119 0 2631 0 3227 0 3727 0 4151 0 4524 0 4819 O 5004 0 5124 0 5232 0 5339 0 5441 0 6084 0 7808 0 37 0 27 01 02 +2S2 STAGE (ft) 0 0000 0 0005 0 0028 0 0062 0 0119 0 0189 0 0233 0 0268 0 0298 0 0318 0 0354 0 0408 0 0439 0 0448 0 0462 0 0476 0 0487 0 0498 0 0509 0 0516 0 0523 0 0532 0 0545 O 0570 0 0595 O 0613 0 0623 0 0629 0 0659 O 0719 O 0771 0 0806 0 0833 0 0855 0 0872 0 0881 0 0887 O 0892 0 0897 0 0902 0 0934 0 0005 100 00 0 0030 100 00 O 0066 100 10 0 0127 100 10 0 0201 100 10 O 0248 100 10 0 0285 100 10 0 0317 100 10 0 0343 100 10 O 0404 100 11 O 0496 100 13 0 0552 100 18 0 0578 100 20 0 0617 100 21 0 0659 100 22 0 0691 100 24 O 0721 100 25 0 0753 100 26 0 0774 100 27 0 0795 100 28 0 0819 100 29 O 0876 100 30 O 0992 100 31 0 1107 100 34 0 1188 100 37 O 1245 100 39 0 1286 100 41 0 1490 100 41 0 1972 100 46 O 2509 100 54 O 2956 100 62 O 3344 100 68 0 3691 100 73 O 3964 100 77 0 4132 100 80 0 4243 100 81 0 4345 100 82 0 4446 100 83 0 4544 100 84 0 5182 100 85 0 6874 100 91 page 16 TIME (min) 40 00 50 00 60 00 70 00 80 00 90 00 100 00 110 00 120 00 130 00 140 00 150 00 160 00 170 00 180 00 190 00 200 00 210 00 220 00 230 00 240 00 250 00 260 00 270 00 280 00 290 00 300 00 310 00 320 00 330 00 340 00 350 00 360 00 370 00 380 00 390 00 400 00 410 00 420 00 430 00 440 00 6/23/06 10 40 3 am Shareware Release Commercial Bldg at First Front Sts for Lindberg /Smith Architects LEVEL POOL ROUTING TABLE page 17 LEVEL POOL ROUTING TABLE I1 I2 2S1 SUM 01 O2 +2S2 STAGE TIME cfs min (ft) (min) O 2062 0 2074 0 5872 1 0009 0 1002 0 9006 101 05 450 00 0 2074 0 2858 0 7932 1 2865 0 1074 1 1791 101 21 460 00 0 2858 0 3648 1 0181 1 6687 0 1610 1 5076 101 41 470 00 0 3648 0 3671 1 3038 2 0358 0 2038 1 8319 101 64 480 00 0 3671 0 2652 1 5856 2 2179 0 2463 1 9716 101 87 490 00 0 2652 0 1619 1 7016 2 1287 0 2700 1 8587 101 98 500 00 0 1619 0 1616 1 6071 1 9307 0 2516 1 6791 101 88 510 00 O 1616 0 1525 1 4574 1 7714 0 2217 1 5498 101 76 520 00 0 1525 0 1439 1 3414 1 6378 0 2084 1 4294 101 67 530 00 0 1439 0 1437 1 2343 1 5220 0 1951 1 3269 101 58 540 00 0 1437 0 1217 1 1442 1 4096 0 1827 1 2270 101 51 550 00 0 1217 0 0996 1 0588 1 2800 0 1682 1 1119 101 44 560 00 0 0996 0 0992 0 9681 1 1669 0 1438 1 0231 101 37 570 00 0 0992 0 0995 0 9048 1 1036 0 1182 0 9853 101 31 580 00 0 0995 0 0988 0 8744 1 0727 0 1109 0 9618 101 29 590 00 0 0988 0 0987 0 8519 1 0494 0 1099 0 9394 101 26 600 00 0 0987 0 0944 0 8304 1 0235 0 1090 0 9145 101 24 610 00 0 0944 0 0902 0 8066 0 9912 0 1080 0 8832 101 22 620 00 0 0902 0 0901 0 7764 0 9567 0 1068 0 8499 101 19 630 00 O 0901 0 0895 0 7442 0 9238 0 1057 0 8180 101 17 640 00 0 0895 0 0900 0 7133 0 8928 0 1047 0 7881 101 15 650 00 0 0900 0 0900 0 6844 0 8643 0 1037 0 7606 101 13 660 00 0 0900 0 0811 0 6577 0 8288 0 1029 0 7259 101 11 670 00 0 0811 0 0721 0 6243 0 7775 0 1016 0 6758 101 08 680 00 0 0721 0 0720 0 5760 0 7202 0 0998 0 6204 101 04 690 00 0 0720 0 0724 0 5226 0 6670 0 0978 0 5693 101 00 700 00 0 0724 0 0719 0 4737 0 6180 0 0956 0 5224 100 96 710 00 0 0719 0 0718 0 4289 0 5726 0 0936 0 4790 100 92 720 00 O 0718 0 0723 0 3875 0 5316 0 0915 0 4401 100 88 730 00 O 0723 0 0718 0 3506 0 4947 0 0895 0 4052 100 84 740 00 0 0718 0 0718 0 3175 0 4610 0 0877 0 3733 100 80 750 00 0 0718 0 0723 0 2875 0 4316 0 0858 0 3458 100 77 760 00 0 0723 0 0718 0 2618 0 4058 0 0840 0 3218 100 74 770 00 0 0718 0 0718 0 2392 0 3828 0 0825 0 3002 100 71 780 00 0 0718 0 0634 0 2192 0 3544 0 0810 0 2734 100 69 790 00 0 0634 0 0544 0 1945 0 3124 0 0789 0 2335 100 65 800 00 0 0544 0 0543 0 1578 0 2666 0 0757 0 1909 100 60 810 00 0 0543 0 0543 0 1197 0 2283 0 0712 0 1571 100 53 820 00 0 0543 0 0542 0 0901 0 1985 0 0671 0 1315 100 47 830 00 0 0542 0 0541 0 0681 0 1765 0 0633 0 1132 100 42 840 00 0 0541 0 0583 0 0531 0 1656 0 0601 0 1055 100 38 850 00 0 0583 0 0630 0 0471 0 1684 0 0584 0 1100 100 36 860 00 O 0630 0 0631 0 0507 0 1768 0 0594 0 1174 100 37 870 00 0 0631 0 0626 0 0564 0 1821 0 0610 0 1211 100 39 880 00 O 0626 0 0631 0 0593 0 1851 0 0618 0 1233 100 40 890 00 0 0631 0 0632 0 0612 0 1875 0 0621 0 1254 100 40 900 00 0 0632 0 0627 0 0629 0 1888 0 0624 0 1264 100 41 910 00 6/23/06 10 40 3 am Shareware Release Commercial Bldg at First Front Sts for Lindberg /Smith Architects LEVEL POOL ROUTING TABLE page 18 LEVEL POOL ROUTING TABLE I1 I2 2S1 SUM 01 02 +2S2 STAGE TIME cfs min (ft) (min) 0 0627 0 0632 0 0638 0 1897 0 0626 0 1271 100 41 920 00 0 0632 0 0632 0 0644 0 1909 0 0627 0 1282 100 41 930 00 0 0632 0 0627 0 0653 0 1913 0 0628 0 1284 100 41 940 00 0 0627 0 0632 0 0656 0 1915 0 0629 0 1287 100 41 950 00 0 0632 0 0633 0 0658 0 1923 0 0629 0 1294 100 41 960 00 0 0633 0 0496 0 0664 0 1793 0 0630 0 1163 100 42 970 00 O 0496 0 0370 0 0555 0 1421 0 0607 0 0814 100 39 980 00 0 0370 0 0368 0 0284 0 1022 0 0530 0 0492 100 29 990 00 O 0368 0 0361 0 0087 0 0816 0 0405 0 0411 100 18 1000 00 0 0361 0 0366 0 0053 0 0780 0 0357 0 0423 100 14 1010 00 0 0366 0 0365 0 0058 0 0789 0 0365 0 0424 100 14 1020 00 0 0365 0 0448 0 0059 0 0872 0 0365 0 0506 100 14 1030 00 0 0448 0 0538 0 0093 0 1078 0 0414 0 0664 100 18 1040 00 0 0538 0 0539 0 0186 0 1262 0 0478 0 0784 100 24 1050 00 0 0539 0 0539 0 0265 0 1342 0 0519 0 0823 100 28 1060 00 0 0539 0 0540 0 0290 0 1369 0 0533 0 0836 100 30 1070 00 0 0540 0 0540 0 0299 0 1379 0 0537 0 0843 100 30 1080 00 0 0540 0 0499 0 0305 0 1343 0 0538 0 0805 100 30 1090 00 0 0499 0 0451 0 0278 0 1228 0 0527 0 0702 100 29 1100 00 0 0451 0 0451 0 0211 0 1113 0 0491 0 0622 100 25 1110 00 0 0451 0 0613 0 0158 0 1222 0 0463 0 0759 100 23 1120 00 O 0613 0 0452 0 0248 0 1313 0 0511 0 0802 100 27 1130 00 0 0452 0 0294 0 0277 0 1022 0 0526 0 0496 100 29 1140 00 O 0294 0 0455 0 0088 0 0837 0 0408 0 0429 100 18 1150 00 0 0455 0 0450 0 0061 0 0965 0 0368 0 0597 100 15 1160 00 0 0450 0 0450 0 0142 0 1041 0 0455 0 0587 100 22 1170 00 0 0450 0 0455 0 0135 0 1040 0 0451 0 0589 100 21 1180 00 0 0455 0 0450 0 0137 0 1041 0 0452 0 0589 100 21 1190 00 O 0450 0 0450 0 0137 0 1037 0 0452 0 0584 100 22 1200 00 0 0450 0 0455 0 0134 0 1039 0 0451 0 0588 100 21 1210 00 0 0455 0 0450 0 0136 0 1041 0 0452 0 0589 100 21 1220 00 0 0450 0 0450 0 0137 0 1037 0 0452 0 0585 100 22 1230 00 O 0450 0 0455 0 0134 0 1039 0 0451 0 0588 100 21 1240 00 0 0455 0 0450 0 0137 0 1042 0 0452 0 0590 100 21 1250 00 O 0450 0 0450 0 0137 0 1037 0 0452 0 0585 100 22 1260 00 O 0450 0 0455 0 0134 0 1039 0 0451 0 0589 100 21 1270 00 0 0455 0 0450 0 0137 0 1042 0 0452 0 0590 100 21 1280 00 0 0450 0 0450 0 0138 0 1038 0 0452 0 0585 100 22 1290 00 0 0450 0 0455 0 0134 0 1040 0 0451 0 0589 100 21 1300 00 0 0455 0 0450 0 0137 0 1042 0 0452 0 0590 100 21 1310 00 0 0450 0 0450 0 0138 0 1038 0 0453 0 0585 100 22 1320 00 0 0450 0 0408 0 0135 0 0993 0 0451 0 0542 100 21 1330 00 O 0408 0 0366 0 0107 0 0881 0 0435 0 0446 100 20 1340 00 0 0366 0 0365 0 0068 0 0799 0 0379 0 0420 100 15 1350 00 0 0365 0 0360 0 0057 0 0782 0 0363 0 0419 100 14 1360 00 0 0360 0 0364 0 0057 0 0781 0 0362 0 0418 100 14 1370 00 0 0364 0 0364 0 0056 0 0785 0 0362 0 0423 100 14 1380 00 6/23/06 10 40.3 am Shareware Release Commercial Bldg at First Front Sts for Lindberg /Smith Architects LEVEL POOL ROUTING TABLE page 19 LEVEL POOL ROUTING TABLE I1 I2 2S1 SUM 01 02 +2S2 STAGE TIME cfs min (ft) (min) 0 0364 0 0359 0 0058 0 0781 0 0365 0 0417 100 14 1390 00 0 0359 0 0364 0 0056 0 0778 0 0361 0 0417 100 14 1400 00 0 0364 0 0364 0 0056 0 0784 0 0361 0 0422 100 14 1410 00 0 0364 0 0358 0 0058 0 0780 0 0364 0 0416 100 14 1420 00 0 0358 0 0364 0 0055 0 0777 0 0361 0 0417 100 14 1430 00 0 0364 0 0364 0 0056 0 0783 0 0361 0 0422 100 14 1440 00 0 0364 0 0185 0 0058 0 0607 0 0364 0 0242 100 14 1450 00 0 0185 0 0010 0 0014 0 0210 0 0228 -0 0018 100 07 1460 00 0 0010 0 0008 -0 0018 0 0000 0 0000 0 0000 100 10 1470 00 0 0008 0 0006 0 0000 0 0014 0 0000 0 0014 100 10 1480 00 0 0006 0 0004 0 0001 0 0011 0 0013 -0 0002 100 10 1490 00 WOHK S 240.000'_ 2.000 2 0.50 .131 klense *t; ktagitittioTZ6 edt; P'ir:sfrVe.:44 EROSION CONTROL Appendix II -A Recommended Standard Notes for Erosion Control Plans The following standard notes are suggested for use in erosion control plans. Local jurisdictions may have other mandatory notes for construction plans that are applicable. Plans should also identify with phone numbers the person or firm responsible for the preparation of and maintenance of the erosion control plan. Standard No Approval of this erosion/sedimentation control (ESC) plan does not constitute an approval of permanent road or drainage design (e.g. size and location of roads, pipes, restrictors, channels, retention facilities, utilities, etc.). The implementation of these ESC plans and the construction, maintenance, replacement, and upgrading of these ESC facilities is the responsibility of the applicant/contractor until all construction is completed and approved and vegetation/landscaping is established. The boundaries of the clearing limits shown on this plan shall be clearly flagged in the field prior to construction. During the construction period, no disturbance beyond the flagged clearing limits shall be permitted The flagging shall be maintained by the applicant/contractor for the duration of construction. The ESC facilities shown on this plan must be constructed in conjunction with all clearing and grading activities, and in such a manner as to insure that sediment and sediment laden water do not enter the drainage system, roadways, or violate applicable water standards. The ESC facilities shown on this plan are the minimum requirements for anticipated site conditions. During the construction period, these ESC facilities shall be upgraded as needed for unexpected storm events and to ensure that sediment and sediment -laden water do not leave the site. The ESC facilities shall be inspected daily by the applicant/contractor and maintained as necessary to ensure their continued functioning. The ESC facilities on inactive sites shall be inspected and maintained a minimum of once a month or within the 48 hours following a major storm event. At no time shall more than one foot of sediment be allowed to accumulate within a trapped catch basin. All catch basins and conveyance lines shall be cleaned prior to paving. The cleaning operation shall not flush sediment laden water into the downstream system. Stabilized construction entrances shall be installed at the beginning of construction and maintained for the duration of the project. Additional measures may be required to insure that all paved areas are kept clean for the duration of the project. August 2001 Volume II Construction Stormwater Pollution Prevention A -1 STORMWATER MANAGEMENT MANUAL FOR THE PUCET SOUND BASIN II-5 6 STRUCTURAL EROSION CONTROL BMPs II -5.6.1 BMP E2.10. Stabilized Construction Entrance and Tire Wash, Definition A temporary stone stabilized pad located at points of vehicular ingres and egress on a construction site Purpose Code To reduce the amount of mud dirt rocks etc transported onto public roads by motor vehicles or runoff by constructing a stabilized pad of rock spalls at entrances to construction sites and washing of tires during egress Conditions Where Practice Applies Planning Considerations Design Criteria Symbol Whenever traffic will be leaving a construction site and moving directly ontc public road or other paved areas Advantages Mud on vehicle tires is significantly reduced which avoids hazards caused by depositing mud on the public roadway Sediment which is otherwise contained on the construction site does not ent stormwater runoff elsewhere Construction entrances provide an area where mud can be removed from vehicle tire before they enter a public road If the action of the vehicle traveling over the gravel pad is not sufficient to remove the majority of the mud then the tires mu be washed before the vehicle enters a public road If washing is used provision must be made to intercept the wash water and trap the sediment before it is carriE off -site Construction entrances should be used in conjunction with the stabilization of construction roads to reduce the amount of mud picked up by vehicles It is important to note that this BMP will only be effective if sediment control used throughout the rest of the construction site Material should be quarry spalls (where feasible), 4 inches to 8 inches size The rock pad shall be at least 12 inches thick and 100 feet in length for sit more than 1 acre and may be reduced to 50 feet in length for sites less thar 1 acre A filter fabric fence (see BMP E3 10) should be installed down gradient from the construction entrance in order to contain any sediment -laden runoff from the entrance Width shall be the full width of the vehicle ingress and egress area (minimun 20 feet) Additional rock should be added periodically to maintain proper function of t pad See Figure II -5 4 for details 1I -5 -30 FEBRUARY 1992 STORMWATER MANAGEMENT MANUAL FOR THE PUGET SOUND BASIN Tire washing should be done before the vehicle enters a paved street Washing should be done on an area covered with crushed rock and the wash water should be drained to a sediment retention facility such as a sediment trap or basin The volume of wash water produced by tire washing should be included when calculating the sediment trap or basin size taintenance The entrance shall be maintained in a condition which will prevent tracking or flow of mud onto public rights -of -way This may require periodic top dressing with 2 -inch stone as conditions demand, and repair and /or cleanout of any structures used to trap sediment All materials spilled dropped washed or tracked from vehicles onto roadways or into storm drains must be removed immediately All temporary erosion and sediment control measures shall be removed within 30 days after final site stabilization is achieved or after the temporary BMPs are no longer needed Trapped sediment shall be removed or stabilized on site Disturbed soil areas resulting from removal shall be permanently stabilized Figure II -5 4 Stabilized Construction Entrance R 25 min 12 min 4 to 8 quarry spalls II -5 -31 provide full width of ingress /egress area FEBRUARY 1992 STORMWATER MANAGEMENT MANUAL FOR THE PUGET SOUND BASIN DRAFT II -5 8 SEDIMENT RETENTION II -5.8.1 BMP E3.10. Filter Fence Code Definition A temporary sediment barrier consisting of a filter fabric stretched across and attached to supporting posts and entrenched The filter fence is constructed of stakes and synthetic filter fabric with a rigid wire fence backing where necessary for support Purpose 1 To intercept and detain small amounts of sediment under sheet flow conditions from disturbed areas during construction operations in order to prevent sediment from leaving the site 2 To decrease the velocity of sheet flows Conditions Where Practice Applies Advantages Symbol Filter fences must be provided just upstream of the point(s) of discharge of runoff from a site before the flow becomes concentrated They may also be required 1 Below disturbed areas where runoff may occur in the form of sheet and ri erosion wherever runoff has the potential to impact downstream resource 2 Perpendicular to minor swales or ditch lines for contributing drainage areas up to one acre in size Downstream riparian areas will not be damaged by sediment deposits originatin from the development Sediment will not cause damage to fish habitat Disadvantages /Problems Filter fences are not practical where large flows of water are involved, henc the need to restrict their use to drainage areas of one acre of less, and flo rates of less than 0 5 cfs This flow should not be concentrated; it should spread out over many linear feet of filter fabric fence Problems may arise from incorrect selection of pore size and /or improper installation Filter fences should not be constructed in streams or used in V- shaped ditche They are not an adequate method of runoff control for anything deeper than sheet or overland flow Planning Considerations Laboratory work at the Virginia Highway and Transportation Research Council has shown that silt fences can trap a much higher percentage of suspended sediments th can straw bales Silt fences are preferable to straw barriers in many cases However, while the failure rate of silt fences is lower than that of straw barrier there are many instances locally in which silt fences have been improperly II -5 -74 FEBRUARY, 1992 STORMWATER MANAGEMENT MANUAL FOR THE PUGET SOUND BASIN DRAFT installed The installation methods outlined here can improve performance Fabric Types There are four types of material used for filter fabric fences; woven slit -film fabric, woven monofilament fabrics, woven composites (of differing materials) and non -woven heat- treated or needle punched fabrics Slit -film fabrics are made from woven sheets of nonporous polymers The sheets are very thin but are cut or slit in wider bands to form the threads which are then woven into the fabric Since slit film weaves use strands that are quite thin, the resulting woven fabric has little rigidity, and pore spaces are not uniform Wire fencing must be used as a backing for this type of filter fabric fence While this type of fabric is generally cheapest and the most widely used, the additional costs of the wire fence installation must be figured in Woven monofilament fabrics are made from uniform spun or extruded filaments which are then woven to form the fabric They are usually thicker and thus more rigid than slit -film fabrics The pores in monofilament fabrics are regularly spaced and the increased rigidity offers more resistance to pore distortion The material has a very low flow- through rate Woven composites are similar in structure but use more than one fiber type Non -woven fabrics are made by using either continuous filaments or short staple fibers These fibers are then bonded together by various processes that can include a needling process that intertwines the fibers physically or a thermal or chemical bonding operation that fuses adjacent fibers together The resulting fabric has a random fiber orientation and may have a thickness that ranges from thick felt to a relatively thin fabric King County Conservation District recently completed tests on 18 different types of filter fabrics Their results have been incorporated into the design criteria Design Criteria Drainage area of 1 acre or less or in combination with sediment basin in a larger site Maximum slope steepness (normal (perpendicular) to fence line) 1 1 Maximum sheet or overland flow path length to the fence 100 feet No concentrated flows greater than 0 5 cfs Selection of a filter fabric is based on soil conditions at the construction site (which affect the apparent opening size (AOS) fabric specification) and characteristics of the support fence (which affect the choice of tensile strength) The designer shall specify a filter fabric that retains the soil found on the construction site yet will have openings large enough to permit drainage and prevent clogging The larger the AOS number, the smaller the AOS size of the opening in the fabric The material used in a filter fabric fence must have sufficient strength to withstand various stress conditions and it also must have the ability to allow passage of water while retaining soil particles The ability to pass flow through must be balanced with the material s ability to trap sediments The following criteria are recommended for selection of the AOS 1 Because of the properties of soils in the Puget Sound basin, field work must be done to determine the optimum AOS for filter fence installations Because of glaciation, many soils in this area contain both cobbles and II -5 -75 FEBRUARY, 1992 STORMWATER MANAGEMENT MANUAL FOR THE PUGET SOUND BASIN DRAFT fines If an SCS standard soil description is used, (e g Alderwood gravelly sandy loam) the AOS specified will not be sufficient to trap th finer particles of soil Including gravels and larger sizes skews the results towards an AOS which is too small to capture suspended settleabl solids and reduce TSS Monofilament and non -woven geotextiles must have minimum AOS of 70 when used in glacial soils Composites and slit film fabrics must be extra strength to perform similarly; in their case the A range may be from 40 -60 In areas where Mazama ash is plentiful in the soil profile, a larger AOS will be necessary, or fabric with an AOS of should be used for outwash soils 2 For all other soil types, the AOS should be determined by first passing soil through a #10 sieve (2 0 mm) Based on the amount of the remaining soil, by weight, which passes through a U S standard sieve No 200, select the AOS to retain 85 percent of the soil Where direct discharge to a stream, lake, or wetland will occur, then the AOS shall be no large than Standard Sieve No 100 Non -woven and regular strength slit film fabrics shall be supported with wire mesh Filter fabric material shall contain ultraviolet ray inhibitors and stabilizers to provide a minimum of six months of expected usable constructic life at a temperature range of 0 °F to 120 °F Standard Notes In addition to the Technical Information Report (see Chapter 1 -3) required by the local government when preparing an erosion and sediment control plan, add the following notes to the Filter Fabric Fence Detail (Figure II -5 18) a The filter fabric shall be purchased in a continuous roll cut to the length c the barrier to avoid use of joints When joints are necessary, filter cloth shall be spliced together only at a support post with a minimum 6 inch overlap and both ends securely fastened to the post b Posts shall be spaced a maximum of 6 feet apart and driven securely into the ground a minimum of 30 inches (where physically possible) c A trench shall be excavated approximately 8 inches wide and 12 inches deep along the line of posts and upslope from the barrier The trench shall be constructed to follow the contour d When slit film filter fabric is used, a wire mesh support fence shall be fastened securely to the upslope side of the posts using heavy -duty wire staples at least 1 inch long, tie wires or hog rings The wire shall extend into the trench a minimum of 4 inches and shall not extend more than 36 inche above the original ground surface e Slit film filter fabric shall be wired to the fence, and 20 inches of the fabric shall extend into the trench The fabric shall not extend more than 36 inches above the original ground surface Filter fabric shall not be stapled to existing trees Other types of fabric may be stapled to the fence f When extra strength or monofilament fabric and closer post spacing are used, the wire mesh support fence may be eliminated In such a case, the filter fabric is stapled or wired directly to the posts with all other provisions of Standard Note e applying Extra care should be used when joining or overlapping these stiffer fabrics g Local governments may specify the use of properly compacted native material In many instances, this may be the preferred alternative because the soil fox a more continuous contact with the trench below and use of native materials II -5 -76 FEBRUARY, 1992 STORMWATER MANAGEMENT MANUAL FOR THE PUGET SOUND BASIN DRAFT cuts down on the number of trips that must be made on and off -site If gravel is used instead, the trench shall be backfilled with k-inch minimum diameter washed gravel Care must be taken when using gravel to ensure good contact between the fabric and the trench bottom to prevent undercutting h Filter fabric fences shall be removed when they have served their useful purpose but not before the upslope area has been permanently stabilized Retained sediment must be removed and properly disposed of or mulched and seeded Maintenance Inspect immediately after each rainfall and at least daily during prolonged rainfall Repair as necessary Sediment must be removed when it reaches approximately one third the height of the fence especially if heavy rains are expected Any sediment deposits remaining in place after the filter fence is no longer required shall be dressed to conform with the existing grade prepared and seeded All temporary erosion and sediment control measures shall be removed within 30 days after final site stabilization is achieved or after the temporary BMPs are no longer needed Trapped sediment shall be removed or stabilized on site Disturbed soil areas resulting from removal shall be permanently stabilized References (1) Kulzer Louise Considerations for Usina Geotextiles in Silt Fence Applications, Metro Technology Transfer Publication Nov 1988 (2) Varney Dick An Evaluation of Geotextiles as Filter Fabric Fence Usina Local Soils for Planning and Enaineerino King County Conservation District Sept 1991 (3) Varney Dick personal communication March 4 1992 II -5 -77 FEBRUARY, 1992 STORMWATER MANAGEMENT MANUAL FOR THE PUGET SOUND BASIN DRAFT L'7 O (V Filter fabric materiel Figure II -5 18 Filter Fabric Fence Detail n L1 Wire mesh support fence for alit film fabrics \WI Provide washed gravel backfill or compacted native soil as directed by local government 2 by 2 wood posts standard or better or equivalent to wire f t p. 1. /Iiiii \q l lriiill�tl !h r/ Bury bottom of filter material in 8 by 12 trench Bury bottom of filter material in 8 by 12 trench Filter fabric material in continuous rolls Use staples or wire rings to attach fabric 6 Max 2 by 2 wood posts standard or better or equivalent (.0 t 8' h9 n O N CV Wire mesh support fence for slit film fabrics O LC) H LI L II -5 -78 FEBRUARY, 1992 STORMWATER MANAGEMENT MANUAL FOR THE PUGET SOUND BASIN I1 -5.8.5 BMP E3.30. Storm Drain Inlet Protection, Purpose Advantages Code Conditions Where Practice Applies II -5 -87 Symbol Definition A sediment filter or an excavated impounding area around a storm drain drop inlet or curb inlet To prevent sediment from entering storm drainage systems prior to permanent stabilization of the disturbed area Where storm drain inlets are to be made operational before permanent stabilization of the disturbed drainage area Different types of structures are applicable to different conditions a Filter Fabric Fence applicable where the inlet drains a relatively small (less than 1 acre) flat area (less than 5 percent slope) (see Figure II- 5 23) Do not place fabric under grate as the collected sediment may fall into the drain when the fabric is retrieved This practice cannot easily be used where the area is paved because of the need for driving stakes to hold the material b Block and Gravel Filter applicable where heavy flows (greater than 0 5 cfs) are expected (Figure II -5 24) c Gravel and Wire Mesh Filter applicable where flows greater than 0 5 cfs are expected and construction traffic may occur over the inlet (Figure II- 5 25) Inlet protection prevents sediment from entering the storm drain system and clogging it Disadvantages /Problems Sediment removal may be difficult especially under high flow conditions Planning Considerations Storm sewers which are made operational before their drainage area is stabilized can convey large amounts of sediment to natural drainageways In cases of extreme sediment loading, the storm sewer itself may clog and lose a major portion of its capacity To avoid these problems, it is necessary to prevent sediment from, entering the system at the inlets There are several types of inlet filters and traps which have different applications dependent upon site conditions and type of inlet Other innovative techniques for accomplishing the same purpose are encouraged but only after specific plans and details are submitted to and approved by the Plan Approving Authority of the local government (see Design Criteria for the description of a new method currently under development by Emcon Northwest) Note that these various inlet protection devices are for drainage areas of less than one acre Runoff from larger disturbed areas should be routed through a Temporary Sediment Trap or Pond (see BMPs E3 35 E3 40) FEBRUARY, 1992 STORMWATER MANAGEMENT MANUAL FOR THE PUGET SOUND BASIN DRAFT The best way to prevent sediment from entering the storm sewer system is to stabilize the site as quickly as possible preventing erosion and stopping sediment at its source Desian Criteria Grates and spaces of all inlets should be secured to prevent seepage of sediment -laden water All inlet protection measures should include sediment sumps of 1 to 2 feet in depth, with 2 1 side slopes (Figure II -5 23) Installation procedure for filter fabric fence a Place 2 inch by 2 inch wooden stakes around the perimeter of the inlet a maximum of 3 feet apart and drive them at least 8 inches into the ground The stakes must be at least 3 feet long b Excavate a trench approximately 8 inches wide and 12 inches deep around the outside perimeter of the stakes c Staple the filter fabric (for materials and specifications see BHP E3 1( Filter Fence) to wooden stakes so that 32 inches of the fabric extends of and can be formed into the trench Use heavy -duty wire staples at least 1 inch in length d Backfill the trench with 3/4 inch or less washed gravel all the way around Installation procedure for block and gravel filter a Place wire mesh over the drop inlet so that the wire extends a minimum o 1 foot beyond each side of the inlet structure Use hardware cloth or comparable wire mesh with one -half inch openings If more than one strL) is necessary overlap the strips Place filter fabric over the wire mes b Place concrete blocks lengthwise on their sides in a single row around ti perimeter of the inlet, so that the open ends face outward, not upward The ends of adjacent blocks should abut The height of the barrier can 1 varied, depending on design needs, by stacking combinations of blocks th are 4 inches, 8 inches, and 12 inches wide The row of blocks should be at least 12 inches but no greater than 24 inches high (Figure II -5 24) c Place wire mesh over the outside vertical face (open end) of the concret( blocks to prevent stone from being washed through the blocks Use hardware cloth or comparable wire mesh with one half inch openings d Pile washed stone against the wire mesh to the top of the blocks Use 3 to 3 inch gravel Installation procedure for gravel and wire mesh filter a Place wire mesh over the drop inlet so that the wire extends a minimum o 1 foot beyond each side of the inlet structure Use hardware cloth or comparable wire mesh with 1/2 inch openings If more than one strip of mesh is necessary, overlap the strips Place filter fabric over wire mesh b Extend the filter fence /wire mesh beyond the inlet opening at least 18 inches on all sides Place 3/4 to 3 -inch gravel over the filter fabric /wire mesh The depth of the gravel should be at least 12 inches II -5 -88 FEBRUARY, 1992 STORMWATER MANAGEMENT MANUAL FOR THE PUGET SOUND BASIN DRAFT Maintenance over the entire inlet opening (see Figure II -5 25) Experimental Inlet Protection BMP. EMCON Northwest, Inc has recently developed a catchbasin filter (patent pending) that prevents sediments and other contaminants from entering storm drainage systems The catchbasin filter is inserted in the catchbasin just below 'the grating The catchbasin filter is equipped with a sediment trap and up to three layers of a fiberglass filter material (see Figure II -5 26) This type of system may not be applicable in all catchbasins but would work well at construction sites, industrial facilities service stations, marinas /boatyards etc During research and development of the catchbasin filter, EMCON Northwest, Inc has found that particulates as small as 15 microns are retained by the filter Additionally high levels of particulate heavy metals, oil and grease and TSS have been removed at both industrial facilities and construction sites The catchbasin filter is equipped with an overflow mechanism which allows it to pass peak flows up to 240 gallons per minute Effective filtration can be accomplished at flows as high as 40 gallons per minute For further information contact John MacPherson at EMCON Northwest Inc (206) 485 -5000 Please note that this information is only While this technology appears controlling some types of pollutants confirm or deny its efficacy at this For systems using stone filters If the sediment the stones must be pulled away replaced Since cleaning of gravel at a alternative approach would be to use the stone around the inlet presented for informational purposes to be an effective method of Ecology is not in a position to time For systems using filter fabric inspections should be made on a regular basis especially after large storm events If the fabric becomes clogged it should be replaced Sediment should be removed when it reaches approximately one -half the height of the fence If a sump is used sediment should be removed when it fills approximately one half the depth of the hole stone filter becomes clogged with from the inlet and cleaned or construction site may be difficult an clogged stone as fill and put fresh All temporary and permanent erosion and sediment control practices shall be maintained and repaired as needed to assure continued performance of their intended function All maintenance and repair shall be conducted in accordance with an approved manual All temporary erosion and sediment control measures shall be removed within 30 days after final site stabilization is achieved or after the temporary BMPs are no longer needed Trapped sediment shall be removed or stabilized on site Disturbed soil areas resulting from removal shall be permanently stabilized II -5 -89 FEBRUARY 1992 STORMWATER MANAGEMENT MANUAL FOR THE PUGET SOUND BASIN Figure II -5 23 Filter Fabric Fence Inlet Filter Drop Inlet with Grate Stakes Filter Fabnc Filter Fabnc Runoff Water with Sediment Buned Filter Fabric f Stakes l -4 i I _Washed Gravel Filtered Water II -5 -90 FEBRUARY, 1992 Runoff Water with Sediment ,I 11 1 =1. Wire Screen Concrete Block STORMWATER MANAGEMENT MANUAL FOR THE PUGET SOUND BASIN =11111- =1UHE: 1111 =III! lI uMITZ1ll `:1111 p 0 1 Sediment Figure II -5 24 Block and Gravel Filter Figure II -5 25 Runoff Water with Sediment Y A f L Sediment Gravel Fitter Overflow TII 6 sri��le d 1� a. L-18 Min Gravel (12 Min depth) Gravel and Wire Mesh Filter II -5 -91 9 1 0 o lo p= Filtered Water ire Screen Filtered Water Drop Inlet with Grate Wire Mesh with Filter Fabric on top FEBRUARY, 1992