Loading...
HomeMy WebLinkAbout1714 W 7th St - BuildingPREPARED 3/02/09 10 07 59 INSPECTION TICKET PAGE 2 CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 3/02/09 ADDRESS 1714 W 7TH ST SUBDIV TENANT NBR GREG MULLIKIN CONTRACTOR PHONE OWNER MULLIKIN RENEE /GREGORY PHONE (360) 693 5640 PARCEL 06 30 00 0 2 4815 0000 APPL NUMBER 06 00000327 RES NEW SFR REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS 2/13/07 AP 02/13/2007 08 51 AM PERMITS Greg 670 6984 02/13/2007 03 15 PM JLIERLY BLI 01 2/16/07 JLL BLDG INSULATION 2/16/07 AP 02/16/2007 08 43 AM PERMITS Gregg Mulliken 683 5684 Cell 670 6984 Key on nail in Garage behind permit roll up doors open 02/16/2007 03 35 PM JLIERLY BL99 01 8/27/07 JLL BLDG FINAL 8/28/07 DA 08/27/2007 08 35 AM LPANGRLE GREG 670 6984 BLDG FINAL 08/28/2007 10 53 AM JLIERLY address s t &p line and dryer vent to exterior /hand rails /exterior deck and landings at all exterior doors /pub works final reqd /jll PW99 01 5/14/08 RV PUBLIC WORKS FINAL 5/14/08 AP BL99 02 3/02/09 PERMIT ME 00 MECHANICAL PERMIT REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS ME99 01 8/27/07 JLL 8/28/07 DA ME99 02 3/02/09 PERMIT PL 00 PLUMBING PERMIT REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS BLDG FINAL TIME 01 00 February 27 2009 1 45 14 PM 1pangrle GREG 670 6984 BLDG FINAL AFTERNOON MECHANICAL FINAL 08/27/2007 08 36 AM LPANGRLE GREG 670 6984 MECHANICAL FINAL 08/28/2007 10 55 AM JLIERLY MECHANICAL FINAL TIME 01 00 February 27 2009 1 46 02 PM 1pangrle GREG 670 6984 MECHANICAL FINAL AFTERNOON PL1 01 6/20/06 JLL PLUMBING UNDER SLAB TIME 13 00 6/20/06 DA GREG 670 6984 06/19/2006 09 23 AM DYASUMUR 06/20/2006 04 39 PM JLIERLY dwv is leaking unable to locate the source/j11 PL1 02 6/26/06 JLL PLUMBING UNDER SLAB TIME 13 00 CONTINUED ONTO NEXT PAGE PREPARED 3/02/09 10 07 59 INSPECTION TICKET PAGE 3 CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 3/02/09 ADDRESS 1714 W 7TH ST SUBDIV TENANT NBR GREG MULLIKIN CONTRACTOR PHONE OWNER MULLIKIN RENEE /GREGORY PHONE (360) 693 5640 PARCEL 06 30 00 0 2 4815 0000 APPL NUMBER 06 00000327 RES NEW SFR REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS 6/26/06 AP GREG 670 6984 06/26/2006 09 47 AM DYASUMUR 06/26/2006 10 46 AM JLIERLY 06/26/2006 04 40 PM JLIERLY PL6 01 7/11/06 JLL PLUMBING WATER SUPPLY TIME 13 00 7/11/06 AP GREG 670 6984 07/10/2006 08 35 AM DYASUMUR 07/11/2006 04 16 PM JLIERLY PL2 01 1/22/07 JLL PLUMBING ROUGH IN 1/22/07 AP 01/22/2007 08 42 AM PBARTHOL 01/22/2007 03 59 PM JLIERLY PLUMBING FINAL 08/27/2007 08 37 AM LPANGRLE GREG 670 6984 PLUMBING FINAL 08/28/2007 10 55 AM JLIERLY PL99 02 3/02/09 J9 PLUMBING FINAL TIME 01 00 February 27 2009 1 46 26 PM 1pangrle PL99 01 8/27/07 JLL 8/28/07 DA GREG 670 6984 PLUMBING FINAL AFTERNOON COMMENTS AND NOTES Application Number Application pin number Property Address ASSESSOR PARCEL NUMBER Tenant nbr name Application type description Subdivision Name Property Use Property Zoning Application valuation Owner Contractor MULLIKIt RENEE /GREGORY 73 IDEA PL SEQUI,M (3 :60) '693 5640 Other struct info Permit Additional desc Permit pin number ,Sub Contractor; Permit 'Fee Issue Date Expiration Date WA 98382 ;Fee summary Charged COMMENTS/ACTION NEEDED CITY OF PORT ANGELES PUBLIC WORKS ELECTRICAL DIVISION 321 EAST.5THSTREET ..PORT ANGELES.WA'9fi3G2• 06 00000327 173551 1714 W 7TH ST 06 30 00 0 2 4815 0000 GREG MULLIKIN RES NEW SFR RS7 RESDNTL SINGLE FAMILY 96892 OWNER TOTAL LOT COVERAGE NUMBER OF STORI'SS> LOT SIZE TOTAL LOT COVERAGE NUMBER OF UNITS ELECTRICAL, NEW RESIDEN,ThAL, .KEYTES/ 1585. SQ FT' SFR- 79541 'KEYTES :EliECTRIC' 96 40 7/07/06 2/24/08 Plan Check Fee Valuation Qty Unit Charge Per 1 00 73 0000 ECH EL R SQFT FIRST 1300 1 00 23 4000 5C EL R SQFT ADDITIONAL 500 Special Notes and Comments Address numbers shall be plainly visible from the street Address numbers shall be a minimum of six inches high and be of contrasting color from the background 04/18/2006 04 44 PM SROBERDS The proposal is for a new sfr in the RS 7 for total lot coverage of 9% No land use issues noted Electrical load calculations and elctrical permits are required connection 'fee required $410 00 04/17/2006 12 15 PM GMCLAIN Sanitary sewer connection inspection is required by Public Works prior to back fill of ditch 24 hour advance notice is required Construct driveway curb apron and Sidewalks to City Standards No concrete with exposed aggregate allowed in the City road right of way An inspection by Public Works Engineering is required prior to prouring concrete 24 hr notice required prior to pouring concrete Other Fees .RES OVERHEAD:SERVICE.FEE STATE SURCHARGE Paid Credited Date 9/21/07 .11 30 7.000 00 792 00 i 00 410 00 Due Extension 73 00 23 40 4 50 00 0 GENERAL COMMENTS: ELECTRICAL PERMIT INSPECTION RECORD ,CALL 417 -4735 FOR ELECTRICAL INSPECTIONS. PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLAWFUL TO COYER, INSULATE OR CONCEAL ANY WORK BEFORE IT IS INSPECTED AND ACCEPTED. KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE INSPECTION TYPE DATE ACCEPTED COMMENTS YES NO DITCH M N ROUGH IN COVER N N SERVICE FINAL M Pw- 1102.1514/96) Application Number Application pin number Permit Fee Total Plan Check Total Other Fee Total Grand Total 14 96 40 00 414 50 510 90 COMMENTS/ACTION NEEDED CITY OF PORT ANGELES PUBLIC WORKS ELECTRICAL DIVISION 321 EAST 5TH STREET PORT ANGELES. WA.98162 06 00000327 173551 96 40 00 414 50 510 90 00 00 00 00 Page 2 Date 9/21/07 00 00 00 00 CALL 417 -4735 FOR ELECTRICAL INSPECTIONS. PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE IT IS INSPECTED AND ACCEPTED. KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE INSPECTION TYPE DATE ACCEPTED COMMENTS YES 1 NO DITCH ROUGH -IN COVERS -off I SERVICE I7 ..7-o -i3O1. i FINAL GENERAL COMMENTS: ELECTRICAL PERMIT INSPECTION RECORD IR o7 1,,4'7,(.1 I 1 D I rw-416.15 (4961 PREPARED 8/27/07 10 52 14 INSPECTION TICKET PAGE 2 CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 8/27/07 ADDRESS 1714 W 7TH ST SUBDIV TENANT NBR GREG MULLIKIN CONTRACTOR PHONE OWNER MULLIKIN RENEE /GREGORY PHONE (360) 693 5640 PARCEL 06 30 00 0 2 4815 0000 APPL NUMBER 06 00000327 RES NEW SFR REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS 2/13/07 AP 02/13/2007 08 51 AM PERMITS Greg 670 6984 02/13/2007 03 15 PM JLIERLY BLI 01 2/16/07 JLL BLDG INSULATION 2/16/07 AP 02/16/2007 08 43 AM PERMITS Gregg Mulliken 683 5684 Cell 670 6984 Key on nail in Garage behind permit roll up doors open 02/16/2007 03 35 PM JLIERLY BL99 01 8/27/07 JLL BLDG FINAL 08/27/2007 08 35 AM LPANGRLE GREG 670 6984 BLDG FINAL PERMIT ME 00 MECHANICAL PERMIT REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS ME99 01 8/27/07 JLL M8/2A/I0A7 FINAL 08/27/2007 08 36 AM LPANGRLE GREG 670 6984 MECHANICAL FINAL PERMIT PL 00 PLUMBING PERMIT REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS PL1 01 6/20/06 JLL PLUMBING UNDER SLAB TIME 13 00 6/20/06 DA GREG 670 6984 06/19/2006 09 23 AM DYASUMUR 06/20/2006 04 39 PM JLIERLY dwv is leaking unable to locate the source /j11 PL1 02 6/26/06 JLL PLUMBING UNDER SLAB TIME 13 00 6/26/06 AP GREG 670 6984 06/26/2006 09 47 AM DYASUMUR 06/26/2006 10 46 AM JLIERLY 06/26/2006 04 40 PM JLIERLY PL6 01 7/11/06 JLL PLUMBING WATER SUPPLY TIME 13 00 7/11/06 AP GREG 670 6984 07/10/2006 08 35 AM DYASUMUR 07/11/2006 04 16 PM JLIERLY PL2 01 1/22/07 JLL PLUMBING ROUGH IN 1/22/07 AP 01/22/2007 08 42 AM PBARTHOL 01/22/2007 03 59 PM JLIERLY PL99 01 8/27/07 JL PLUMBING FINAL 08/27/2007 08 37 AM LPANGRLE GREG 670 6984 PLUMBING FINAL COMMENTS AND NOTES Date 0 BUILDING DIVISION CITY OF PORT ANGELES Correction Notice Job Located at 141 1 7/ 11 r r Inspection of your work revealed that the following is not in accordance with the codes governing the work in this jurisdiction j w Li_ �4 g i i d,-, 40 R 1 o 1 C i ti_ i/`L r ...--7 .-J 1 r /t t o f v /4A v nspecto &,for Building Division DO NOT REMOVE THIS TAG These corrections must be made and are not to be covered until reinspection is made When corrections have been made, please call /j c /k for inspection PREPARED 2/16/07 9 32 27 INSPECTION TICKET PAGE 2 CITY OF PORT ANGELES INSPECTOR JAMES L LIERLY DATE 2/16/07 ADDRESS 1714 W 7TH ST SUBDIV TENANT NBR GREG MULLIKIN CONTRACTOR PHONE OWNER MULLIKIN RENEE /GREGORY PHONE (360) 693 5640 PARCEL 06 30 00 0 2 4815 0000 APPL NUMBER 06 00000327 RES NEW SFR REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS 2/13/07 AP BLI 01 2/16/07 02/13/2007 08 51 AM PERMITS Greg 670 6984 02/13/2007 03 15 PM JLIERLY BUILDING INSULATION 02/16/2007 08 43 AM PERMITS Gregg Mulliken 683 5684 Cell 670 6984 Key on nail in Garage behind permit roll up doors open COMMENTS AND NOTES PREPARED 2/13/07 9 14 36 INSPECTION TICKET CITY OF PORT ANGELES INSPECTOR JAMES L LIERLY DATE 2/13/07 ADDRESS 1714 W 7TH ST SUBDIV TENANT NBR GREG MULLIKIN CONTRACTOR PHONE OWNER MULLIKIN RENEE /GREGORY PHONE (360) 693 5640 PARCEL 06 30 00 0 2 4815 0000 APPL NUMBER 06 00000327 RES NEW SFR REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESUL RESULTS /COMMENTS v -t( 02/13/2007 08 51 AM PERMITS Greg 670 6984 COMMENTS AND NOTES PAGE 8 PREPARED 2/08/07 13 08 03 INSPECTION TICKET PAGE 9 CITY OF PORT ANGELES INSPECTOR JAMES L LIERLY DATE 2/08/07 ADDRESS 1714 W 7TH ST SUBDIV TENANT NBR GREG MULLIKIN CONTRACTOR PHONE OWNER MULLIKIN RENEE /GREGORY PHONE (360) 693 5640 PARCEL 06 30 00 0 2 4815 0000 APPL NUMBER 06 00000327 RES NEW SFR PERMIT BPR 00 BUILDING PERMIT RESIDENTIAL REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS BL1 01 5/30/06 JLL BUILDING FOUNDATION FOOTING TIME 13 00 5/31/06 DA GREG 670 6984 05/26/2006 03 26 PM DYASUMUR BL1 02 05/31/2006 08 28 AM PBARTHOL INSTALL 20 GROUND 6/02/06 JLL BUILDING FOUNDATION FOOTING TIME 13 00 6/02/06 AP GREG 670 6984 06/01/2006 08 10 AM DYASUMUR 06/02/2006 03 19 PM JLIERLY 20 ground BL2 01 6/12/06 JLL BUILDING FOUNDATION WALL TIME 13 00 6/13/06 DA OVERRIDE TAKEN BY DYASUMUR DATE 06/12/06 TIME 07 52 32 GREG 670 6984 STEMWALL 06/12/2006 07 52 AM DYASUMUR 06/13/2006 08 41 AM JLIERLY abs cannot be directly embedded in concrete owner wanted to wet set anchor bolts/ explained that they would need to be 4 0 o c and within 12 of each end of p t sill/j11 BLED 01 6/30/06 JLL BUILDING FOUNDATION DRAINAGE 6/30/06 AP 06/30/2006 03 49 PM JLIERLY DRW 01 6/30/06 JLL BUILDING DRYWELL 6/30/06 AP 06/30/2006 03 49 PM JLIERLY DSD 01 6/30/06 JLL BUILDING DOWN SPOUT DRAINS 6/30/06 AP 06/29/2006 04 29 PM PBARTHOL GREG 670 6984 06/30/2006 03 49 PM JLIERLY BLM 01 7/17/06 JLL BUILDING FOUNDATION MONO SLAB TIME 13 00 7/17/06 AP GREG 670 6984 07/17/2006 07 51 AM DYASUMUR 07/17/2006 04 24 PM JLIERLY BLDR 01 8/15/06 JLL BUILDING DRYWALL IBWP TIME 13 00 8/15/06 AP GREG 670 6984 08/15/2006 08 03 AM DYASUMUR 08/15/2006 05 28 PM JLIERLY exterior shear wall nail pattern/j11 BL3 01 1/22/07 JLL BUILDING FRAMING 1/22/07 DA 01/22/2007 08 41 AM PBARTHOL GREG MILLIKIN 670 6984 01/22/2007 03 57 PM JLIERLY STEPS AT LOWER LANDING /FIRE BLOCK STAIRS /MECH EXHAUST FAN DUCT AND TERMINATIONS /VERIFY ELEC INSPEC TRUSS DETAILS/ REMOVE FOAM AT HEADERS FOR INSP AIR SEAL REQUIRED /JLL BL3 02 2/1:/07 JLL BUILDING FRAMING n 02/08/2007 08 15 AM PERMITS GREG 360 683 5640 KEY ON FIRE BLOCK NEXT TO ELECTRICAL PANEL TRUSS INFO CLIPPED TO PERMIT COMMENTS AND NOTES Date BUILDING DIVISION CITY OF PORT Correction Notice Job Located at 1,Lt Inspection of your work revealed that the following is not in accordance with the codes governing the wortin. this jurisdiction t 1 4 DO NOT NOT REMOVE THIS TAG These corrections. must be made and are not to be covered until teinspection is made Mien corrections have been made, please call eN 4/b/r for inspection 3-4 Inspector fo Division 1 BUILDING DIVISION CITY OF PORT ANGELES Correction Notice Job Located at I C I vv Inspection of your work revealed that the following is not in accordance with the codes governing the work in this jurisdiction These corrections must be made and are not to be covered until reinspection is m de. When correc have been made, please call for inspection Date il DO NOT REMOVE THIS TAG sector for Building Division PREPARED 1/22/07 10 19 03 CITY OF PORT ANGELES ADDRESS 1714 W 7TH ST TENANT NBR GREG MULLIKIN CONTRACTOR OWNER MULLIKIN RENEE /GREGORY PARCEL 06 30 00 0 2 4815 0000 APPL NUMBER 06 00000327 RES NEW SFR PERMIT BPR 00 BUILDING PERMIT RESIDENTIAL REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS BL1 01 5/30/06 JLL 5/31/06 DA BL1 02 6/02/06 JLL 6/02/06 AP BL2 01 6/12/06 JLL 6/13/06 DA BLFD 01 6/30/06 JLL 6/30/06 AP DRW 01 6/30/06 JLL 6/30/06 AP DSD 01 6/30/06 JLL 6/30/06 AP BLM 01 7/17/06 JLL 7/17/06 AP BLDR 01 8/15/06 JLL 8/15/06 AP BL3 01 1/22/07 PERMIT PL 00 PLUMBING PERMIT REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS PL1 01 6/20/06 JLL 6/20/06 DA PL1 02 6/26/06 JLL 6/26/06 AP INSPECTION TICKET INSPECTOR JAMES L LIERLY SUBDIV PHONE PHONE (360) 693 5640 BUILDING FOUNDATION FOOTING TIME 13 00 GREG 670 6984 05/26/2006 03 26 PM DYASUMUR 05/31/2006 08 28 AM PBARTHOL INSTALL 20 GROUND BUILDING FOUNDATION FOOTING TIME 13 00 GREG 670 6984 06/01/2006 08 10 AM DYASUMUR 06/02/2006 03 19 PM JLIERLY 20 ground BUILDING FOUNDATION WALL TIME 13 00 OVERRIDE TAKEN BY DYASUMUR DATE 06/12/06 TIME 07 52 32 GREG 670 6984 STEMWALL 06/12/2006 07 52 AM DYASUMUR 06/13/2006 08 41 AM JLIERLY abs cannot be directly embedded in concrete owner wanted to wet set anchor bolts/ explained that they would need to be 4 0 o c and within 12 of each end of p t sill/j11 BUILDING FOUNDATION DRAINAGE 06/30/2006 03 49 PM JLIERLY BUILDING DRYWELL 06/30/2006 03 49 PM JLIERLY BUILDING DOWN SPOUT DRAINS 06/29/2006 04 29 PM PBARTHOL GREG 670 6984 06/30/2006 03 49 PM JLIERLY BUILDING FOUNDATION MONO SLAB TIME 13 00 GREG 670 6984 07/17/2006 07 51 AM DYASUMUR 07/17/2006 04 24 PM JLIERLY BUILDING DRYWALL IBWP TIME 13 00 GREG 670 6984 08/15/2006 08 03 AM DYASUMUR 08/15/2006 05 28 PM JLIERLY exterior shear wall nail pattern/j11 BUILDING FRAMING 01/22/2007 08 41 AM PBARTHOL GREG MILLIKIN 670 6984 PLUMBING UNDER GREG 670 6984 06/19/2006 09 06/20/2006 04 dwv is leaking PLUMBING UNDER GREG 670 6984 SLAB TIME 13 00 23 AM DYASUMUR 39 PM JLIERLY unable to locate the source/j11 SLAB TIME 13 00 CONTINUED ONTO NEXT PAGE PAGE 6 DATE 1/22/07 PREPARED 1/22/07 10 19 03 INSPECTION TICKET PAGE 7 CITY OF PORT ANGELES INSPECTOR JAMES L LIERLY DATE 1/22/07 ADDRESS 1714 W 7TH ST SUBDIV TENANT NBR GREG MULLIKIN CONTRACTOR PHONE OWNER MULLIKIN RENEE /GREGORY PHONE (360) 693 5640 PARCEL 06 30 00 0 2 4815 0000 APPL NUMBER 06 00000327 RES NEW SFR REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS 06/26/2006 09 47 AM DYASUMUR 06/26/2006 10 46 AM JLIERLY 06/26/2006 04 40 PM JLIERLY PL6 01 7/11/06 JLL PLUMBING WATER SUPPLY TIME 13 00 7/11/06 AP GREG 670 6984 07/10/2006 08 35 AM DYASUMUR 07/11/2006 04 16 PM JLIERLY PL2 01 1/22/07 PLUMBING ROUGH IN 01/22/2007 08 42 AM PBARTHOL COMMENTS AND NOTES PREPARED 8/15/06 11 13 42 INSPECTION TICKET PAGE 2 CITY OF PORT ANGELES INSPECTOR JAMES L LIERLY DATE 8/15/06 ADDRESS 1714 W 7TH ST SUBDIV TENANT NBR GREG MULLIKIN CONTRACTOR PHONE OWNER MULLIKIN RENEE /GREGORY PHONE (360) 693 5640 PARCEL 06 30 00 0 2 4815 0000 APPL NUMBER 06 00000327 RES NEW SFR PERMIT BPR 00 BUILDING PERMIT RESIDENTIAL REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS BL1 01 5/30/06 JLL 5/31/06 DA BL1 02 6/02/06 JLL 6/02/06 AP BUILDING FOUNDATION FOOTING TIME 13 00 GREG 670 6984 05/26/2006 03 26 PM DYASUMUR 05/31/2006 08 28 AM PBARTHOL INSTALL 20 GROUND BUILDING FOUNDATION FOOTING TIME 13 00 GREG 670 6984 06/01/2006 08 10 AM DYASUMUR 06/02/2006 03 19 PM JLIERLY 20 ground BL2 01 6/12/06 JLL BUILDING FOUNDATION WALL TIME 13 00 6/13/06 DA OVERRIDE TAKEN BY DYASUMUR DATE 06/12/06 TIME 07 52 32 GREG 670 6984 STEMWALL 06/12/2006 07 52 AM DYASUMUR 06/13/2006 08 41 AM JLIERLY abs cannot be directly embedded in concrete owner wanted to wet set anchor bolts/ explained that they would need to be 4 0 o c and within 12 of each end of p t sill/j11 BLFD 01 6/30/06 JLL BUILDING FOUNDATION DRAINAGE 6/30/06 AP 06/30/2006 03 49 PM JLIERLY DRW 01 6/30/06 JLL BUILDING DRYWELL 6/30/06 RP 06/30/2006 03 49 PM JLIERLY DSD 01 6/30/06 JLL BUILDING DOWN SPOUT DRAINS 6/30/06 AP 06/29/2006 04 29 PM PBARTHOL GREG 670 6984 06/30/2006 03 49 PM JLIERLY BLM 01 7/17/06 JLL BUILDING FOUNDATION MONO SLAB TIME 13 00 7/17/06 AP GREG 670 6984 0 7/ 17 /2006 07 51 AM DYASUMUR 07/17/2006 04 24 PM JLIERLY BLDR 01 8/15/06 ,5LI BUI DRYWALL IBWP TIME 13 00 ___4 J GREG 670 6984 08/15/2006 08 03 AM DYASUMUR COMMENTS AND NOTES PREPARED 7/17/06 12 26 46 INSPECTION TICKET PAGE 9 CITY OF PORT ANGELES INSPECTOR JAMES L LIERLY DATE 7/17/06 ADDRESS 1714 W 7TH ST SUBDIV TENANT NBR GREG MULLIKIN CONTRACTOR PHONE OWNER MULLIKIN RENEE /GREGORY PHONE (360) 693 5640 PARCEL 06 30 00 0 2 4815 0000 APPL NUMBER 06 00000327 RES NEW SFR PERMIT BPR 00 BUILDING PERMIT RESIDENTIAL REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS BL1 01 5/30/06 JLL BUILDING FOUNDATION FOOTING TIME 13 00 5/31/06 DA GREG 670 6984 05/26/2006 03 26 PM DYASUMUR 05/31/2006 08 28 AM PBARTHOL INSTALL 20 GROUND BL1 02 6/02/06 JLL BUILDING FOUNDATION FOOTING TIME 13 00 6/02/06 AP GREG 670 6984 06/01/2006 08 10 AM DYASUMUR 06/02/2006 03 19 PM JLIERLY 20 ground BL2 01 6/12/06 JLL BUILDING FOUNDATION WALL TIME 13 00 6/13/06 DA OVERRIDE TAKEN BY DYASUMUR DATE 06/12/06 TIME 07 52 32 GREG 670 6984 STEMWALL 06/12/2006 07 52 AM DYASUMUR 06/13/2006 08 41 AM JLIERLY abs cannot be directly embedded in concrete owner wanted to wet set anchor bolts/ explained that they would need to be 4 0 o c and within 12 of each end of p t sill/j11 BLFD 01 6/30/06 JLL BUILDING FOUNDATION DRAINAGE 6/30/06 AP 06/30/2006 03 49 PM JLIERLY DRW 01 6/30/06 JLL BUILDING DRYWELL 6/30/06 AP 06/30/2006 03 49 PM JLIERLY DSD 01 6/30/06 JLL BUILDING DOWN SPOUT DRAINS 6/30/06 AP 06/29/2006 04 29 PM PBARTHOL GREG 670 6984 06/30/2006 03 49 PM JLIERLY BLM O1 7/ p6 JLL GRIGDI7G 6OUNDATION MONO SLAB TIME 13 00 GREG 670 6984 07/17/2006 07 51 AM DYASUMUR COMMENTS AND NOTES PREPARED 7/11/06 12 30 51 CITY OF PORT ANGELES ADDRESS TENANT NBR CONTRACTOR OWNER PARCEL APPL NUMBER PERMIT TYP /SQ PL1 01 PL1 02 PL6 01 1714 W 7TH ST GREG MULLIKIN MULLIKIN RENEE /GREGORY 06 30 00 0 2 4815 0000 06 00000327 RES NEW SFR PL 00 PLUMBING PERMIT REQUESTED INSP DESCRIPTION COMPLETED RESULT RESULTS /COMMENTS 6/20/06 JLL 6/20/06 DA 6/26/06 JLL 6/26/06 AP 7/11/06 J INSPECTION TICKET INSPECTOR JAMES L LIERLY PLUMBING UNDER SLAB GREG 670 6984 06/19/2006 09 06/20/2006 04 dwv is leaking PLUMBING UNDER GREG 670 6984 06/26/2006 09 06/26/2006 10 06/26/2006 04 PLUMBING WATER GREG 670 6984 07/10/2006 08 SUBDIV COMMENTS AND NOTES PHONE PHONE (360) 693 5640 TIME 13 00 23 AM DYASUMUR 39 PM JLIERLY unable to locate the source/j11 SLAB TIME 13 00 47 AM DYASUMUR 46 AM JLIERLY 40 PM JLIERLY SUPPLY TIME 13 00 35 AM DYASUMUR PAGE 6 DATE 7/11/06 PREPARED 6/30/06 8 55 20 INSPECTION TICKET PAGE 18 CITY OF PORT ANGELES INSPECTOR JAMES L LIERLY DATE 6/30/06 ADDRESS 1714 W 7TH ST SUBDIV TENANT NBR GREG MULLIKIN CONTRACTOR PHONE OWNER MULLIKIN RENEE /GREGORY PHONE (360) 693 5640 PARCEL 06 30 00 0 2 4815 0000 APPL NUMBER 06 00000327 RES NEW SFR PERMIT BPR 00 BUILDING PERMIT RESIDENTIAL REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS BL1 01 5/30/06 JLL BUILDING FOUNDATION FOOTING TIME 13 00 5/31/06 DA GREG 670 6984 05/26/2006 03 26 PM DYASUMUR 05/31/2006 08 28 AM PBARTHOL INSTALL 20 GROUND BL1 02 6/02/06 JLL BUILDING FOUNDATION FOOTING TIME 13 00 6/02/06 AP GREG 670 6984 06/01/2006 08 10 AM DYASUMUR 06/02/2006 03 19 PM JLIERLY 20 ground BL2 01 6/12/06 JLL BUILDING FOUNDATION WALL TIME 13 00 6/13/06 DA OVERRIDE TAKEN BY DYASUMUR DATE 06/12/06 TIME 07 52 32 GREG 670 6984 STEMWALL 06/12/2006 07 52 AM DYASUMUR 06/13/2006 08 41 AM JLIERLY abs cannot be directly embedded in concrete owner wanted to wet set anchor bolts/ explained that they would need to be 4 0 o C and BLFD 01 6i x /06 LL I BUILDING FOUNDATION n each end of p t sill/j11 DRAINAGE DRW 01 6/30/06 J L BUILDING DRYWELL }/L DSD 01 6/30/06 L BUILDING DOWN SPOUT DRAINS 06/29/2006 04 29 PM PBARTHOL GREG 670 6984 COMMENTS AND NOTES PREPARED 6/26/06 10 52 54 INSPECTION TICKET PAGE 1 CITY OF PORT ANGELES INSPECTOR JAMES L LIERLY DATE 6/26/06 ADDRESS 1714 W 7TH ST SUBDIV TENANT NBR GREG MULLIKIN CONTRACTOR PHONE OWNER MULLIKIN RENEE /GREGORY PHONE (360) 693 5640 PARCEL 06 30 00 0 2 4815 0000 APPL NUMBER 06 00000327 RES NEW SFR PERMIT PL 00 PLUMBING PERMIT REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS PL1 01 6/20/06 JLL PLUMBING UNDER SLAB TIME 13 00 6/20/06 DA GREG 670 6984 06/19/2006 09 23 AM DYASUMUR 06/20/2006 04 39 PM JLIERLY dwv is leaking unable to locate the source/j11 PL1 02 6 26/06 JLL PLUMBING UNDER SLAB TIME 13 00 GREG 670 6984 06/26/2006 09 47 AM DYASUMUR 06/26/2006 10 46 AM JLIERLY COMMENTS AND NOTES MULLIKIN RENEE /GREGORY OWNER 73 IDEA PL SEQUIM WA 98382 (360) 693 5640 Other struct info TOTAL LOT COVERAGE NUMBER OF STORIES LOT SIZE TOTAL LOT COVERAGE NUMBER OF UNITS Application Number 06 00000327 Date 6/22/06 Application pin number 173551 Property Address 1714 W 7TH ST ASSESSOR PARCEL NUMBER 06 30 00 0 2 -4815 0000 Tenant nbr name GREG MULLIKIN Application type description RES NEW SFR Subdivision Name Property Use Property Zoning RS7 RESDNTL SINGLE FAMILY Application valuation 96892 Owner Contractor CITY OF PORT ANGELES PUBLIC WORKS UTILITIES DIVISION 321 EAST'3TH STREET PORT ANGELES, WA 98362 11 30 2 00 7000 00 792 00 1 00 Permit STREET ALLEY RESTORATION Additional desc POWER CROSSING Permit pin number 80408 Permit Fee 270 00 Plan Check Fee 00 Issue Date 6/19/06 Valuation 96892 Expiration Date 12/17/06 Qty Unit Charge Per 1 00. 270 0000 ECH STREET ALLEY RESTORATION Special Notes and Comments Address numbers shall be plainly visible from the street Address numbers shall be a minimum of six inches high and be of contrasting color from the background 04/18/2006 04 44 PM SROBERDS The proposal is for a new sfr in the RS 7 for total lot coverage of 9% No land use issues noted Electrical load calculations and elctrical permits are required connection fee required $410 00 04/17/2006 12 15 PM GMCLAIN Sanitary sewer connection inspection is required by Public Works prior to back fill of ditch 24 hour advance notice is required Construct driveway curb apron and Sidewalks to City Standards No concrete with exposed aggregate allowed in the City road right of way An inspection by Public Works Engineering is required prior to prouring concrete 24 hr notice required prior to pouring concrete Other Fees RES OVERHEAD S FEE 410 00 STATE SURCHARGE 4 50 Fee summary Charged Paid Credited Due Permit Fee Total T•\Policies \1102.13k [1 /05] 270 00 270 00 00 00 Extension 270 00 Separate Permits are required for electrical work, SEPA, Shoreline, ESA, utilities, private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned fora period of 180 days after the work as commenced, or if required inspections have not been requested within 180 days from the last inspection. 1 hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances goveming this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. r Signature of Contractor or Authorized Agent Date Signattof r owner is builder) Date CALL 417 -4807 FOR UTILITY INSPECTIONS. PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT IN A CONSPICUOUS LOCATION. PW UTILITIES (Engineering Division) WATERLINE METER SEWER CONNECTION SANITARY STORM SITE DRAINAGE SITE EROSION CONTROL PARKING SIDEWALK CURB GUTTER DRIVEWAY APPROACH BACK -FLOW DEVICE CONSTRUCTION RW PW/ 417 -4807 ENGINEERING FIRE 417 -4653 PLANNING DEPT 417-4750 BUILDING 417 -4815 T-\Policies \1102.15R 1 /05) RESIDENTIAL PERMIT INSPECTION RECORD KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE INSPECTION TYPE DATE ACCEPTED YES 1 NO 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 .1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE DATE YES NO COMMERCIAL DATE ACCEPTED YES 1 NO 1 1 1 1 1 1 1 1 CONSTRUCTION RW PW ENGINEERING 1 FIRE DEPT 1 PLANNING DEPT BUILDING COMMENTS 1 1 1 1 1 1 1 1 1 ittesyso CITY OF PORT ANGELES PUBLIC WORKS UTILITIES DIVISION 321 EAST STH STREET PORT ANGELES, WA 98362 Page 2 Application Number 06 00000327 Date 6/22/06 Application pin number 173551 Plan Check Total 00 00 00 00 Other Fee Total 414 50 414 50 00 00 Grand Total 684 50 684 50 00 00 Separate Permits are required for electrical work, SEPA, Shoreline, ESA, utilities, private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned for a period of 180 days after the work as commenced, or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances goveming this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. Signature of Contractor or Authorized Agent Date Signature of Owner (if owner is builder) Date T•\Policies \1102.158 [1 /05) CALL 417 -4807 FOR UTILITY INSPECTIONS. PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT IN A CONSPICUOUS LOCATION. KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE TA Policies 11/051 PW UTILITIES (Engineering Division) WATERLINE METER SEWER CONNECTION SANITARY STORM SITE DRAINAGE SITE EROSION CONTROL PARKING SIDEWALK CURB GUTTER DRIVEWAY APPROACH BACK -FLOW DEVICE INSPECTION TYPE DATE ACCEPTED YES 1 NO RESIDENTIAL CONSTRUCTION R.W PW/ 417 -4807 ENGINEERING FIRE 417 -4653 I PLANNING DEPT 417 -4750 I BUILDING 417 -4815 PERMIT INSPECTION RECORD 1 1 1 1 1 I I 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1. 1 1 1 1 1 1 COMMENTS FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE DATE YES NO COMMERCIAL DATE ACCEPTED 1 I 1 1 I 1 1 1 CONSTRUCTION R.W PW ENGINEERING I FIRE DEPT I PLANNING DEPT BUILDING Application Number Application pin number Property Address ASSESSOR PARCEL NUMBER Tenant nbr name Application type description Subdivision Name Property Use Property Zoning Application valuation Owner MULLIKIN RENEE /GREGORY 73 IDEA PL SEQUIM (360) 693 5640 Other struct info Permit Additional desc Permit pin number 80481 Permit Fee 89 65 Issue Date 6/19/06 Expiration Date 12/17/06 Qty Unit Charge 4 00 1 00 Permit Additional desc Permit pin number Permit Fee Issue Date Expiration Date WA 98382 7 2500 ECH 10 6500 ECH Qty Unit Charge Per MECHANICAL PERMIT Per PLUMBING PERMIT 80499 120 00 6/19/06 12/17/06 BASE FEE 10 00 7 0000 ECH PL EA FIXTURE ON ONE TRAP Special Notes and Comments Address numbers shall be plainly visible from the street Address numbers shall be a minimum of six inches high and be of contrasting color from the background 04/18/2006 04 44 PM SROBERDS The proposal is for a new sfr in the RS 7 for total lot coverage of 9% No land use issues noted Electrical load calculations and elctrical permits are required connection fee required $410 00 04/17/2006 12 15 PM GMCLAIN Sanitary sewer connection inspection is required by Public Works prior to back fill of ditch 24 hour advance Separate Permits are required for electrical work, SEPA, Shoreline, ESA, utilities, private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned for a period of 180 days after the work as commenced, or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating c structi n or the performance of construction. Signature of Contractor or Authorized Agent Date T•\Policies \1102_15 building permit inspection record05.wpd [1/4/2005] CITY OF PORT ANGELES DEPARTMENT OF COMMUNITY DEVELOPMENT BUILDING DIVISION 321 EAST 5Th STREET PORT ANGELES, WA 98362 06 00000327 173551 1714 W 7TH ST 06 30 00 0 2 4815 0000 GREG MULLIKIN RES NEW SFR RS7 RESDNTL SINGLE FAMILY 96892 Contractor OWNER TOTAL LOT COVERAGE NUMBER OF STORIES LOT SIZE TOTAL LOT COVERAGE NUMBER OF UNITS Plan Check Fee Valuation BASE FEE ME VENT FAN ME VENT SYSTEM OTHER Plan Check Fee Valuation Date 6/22/06 11 30 2 00 7000 00 792 00 1 00 00 0 Extension 50 00 29 00 10 65 00 0 Extension 50 00 70 00 �i s atyreJ Owner (if owner is builder) Date BUILDING PERMIT INSPECTION RECORD CALL 417 -4815 FOR BUILDING INSPECTIONS. CALL 417 -4735 FOR ELECTRICAL INSPECTIONS. CALL 417 -4807 FOR PUBLIC WORKS UTILITIES PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT IN A CONSPICUOUS LOCATION. KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE. INSPECTION TYPE DATE ACCEPTED COMMENTS FOUNDATION: FOOTINGS WALLS FOUNDATION DRAINAGE DOWN SPOUTS PIERS POST HOLES (POLE BLDGS.) PLUMBING UNDER FLOOR SLAB ROUGH -IN WATER LINE (METER TO BLDG) GAS LINE BACK FLOW/ WATER AIR SEAL WALLS CEILING FRAMING JOISTS GIRDERS SHEAR WALL/HOLD DOWNS WALLS ROOF CEILING DRYWALL (INTERIOR BRACED PANEL ONLY) T -BAR INSULATION SLAB WALL FLOOR CEILING MECHANICAL HEAT PUMP FURNACE 1 DUCTS GAS LINE WOOD STOVE PELLET CHIMNEY COMMERCIAL HOOD DUCTS MANUFACTURED HOMES FOOTING SLAB BLOCKING HOLD DOWNS SKIRTING PLANNING DEPT SEPARATE PERMIT #'s PARKING/LIGHTING LANDSCAPING RESIDENTIAL ELECTRICAL LIGHT DEPT CONSTRUCTION R.W PWI ENGINEERING 4174807 FIRE 417 -4653 1 PLANNING DEPT 417 -4750 1 BUILDING 417 -4815 1 -A no 1c t,. ttai.,o nwrmit incoection record05.wpd (1 /4/2005) 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 FINAL FINAL SEPA. ESA. SHORELINE: 4174735 ELECTRICAL LIGHT DEPT CONSTRUCTION R.W PW ENGINEERING 1 FIRE DEPT 1 1 PLANNING DEPT 1 1 BUILDING 1 DATE ACCEPTED BY. DATE ACCEPTED BY. FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE DATE YES NO COMMERCIAL DATE ACCEPTED YES 1 NO Application Number Application pin number Special Notes and Comments notice is required Construct driveway curb apron and Sidewalks to City Standards No concrete with exposed aggregate allowed in the City road right of way An inspection by Public Works Engineering is required prior to prouring concrete 24 hr notice required prior to pouring concrete Other Fees Fee summary Permit Fee Total 209 65 209 65 00 00 Plan Check Total 00 00 00 00 Other Fee Total 414 50 414 50 00 00 Grand Total 624 15 624 15 00 00 06 00000327 173551 Separate Permits are required for electrical work, SEPA, Shoreline, ESA, utilities, private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned for a period of 180 days after the work as commenced, or if required inspections have not been requgsted within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. Signature of Contractor or Authorized Agent Date Signature of Owner (if owner is builder) Date T•\Policies \1102_15 building permit inspection record05.wpd [1/4/2005] CITY OF PORT ANGELES DEPARTMENT OF COMMUNITY DEVELOPMENT BUILDING DIVISION 321 EAST 5TH STREET PORT ANGELES, WA 98362 Charged Paid Credited Due Page 2 Date 6/22/06 RES OVERHEAD SERVICE FEE 410 00 STATE SURCHARGE 4 50 BUILDING PERMIT INSPECTION RECORD CALL 417 -4815 FOR BUILDING INSPECTIONS. CALL 417 -4735 FOR ELECTRICAL INSPECTIONS. CALL 417 -4807 FOR PUBLIC WORKS UTILITIES PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT IN A CONSPICUOUS LOCATION. KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE. INSPECTION TYPE DATE ACCEPTED COMMENTS YES I NO FOUNDATION: FOOTINGS WALLS FOUNDATION DRAINAGE DOWN SPOUTS PIERS POST HOLES (POLE BLDdS.) PLUMBING UNDER FLOOR SLAB ROUGH -IN WATER LINE (METER TO BLDG) GAS LINE BACK FLOW WATER AIR SEAL WALLS CEILING FRAMING JOISTS GIRDERS SHEAR WALL/HOLD DOWNS WALLS ROOF CEILING DRYWALL (INTERIOR BRACED PANEL ONLY) T -BAR INSULATION SLAB WALL FLOOR CEILING MECHANICAL HEAT PUMP FURNACE DUCTS GAS LINE WOOD STOVE PELLET CHIMNEY COMMERCIAL HOOD DUCTS MANUFACTURED HOMES FOOTING SLAB BLOCKING HOLD DOWNS SKIRTING PLANNING DEPT SEPARATE PERMIT #'s PARKING/LIGHTING LANDSCAPING RESIDENTIAL ELECTRICAL LIGHT DEPT CONSTRUCTION ILW PW/ ENGINEERING 417-4807 FIRE 417 -4653 PLANNING DEPT 417 -4750 1 BUILDING 417 -4815 I r ❑a: a.,mr mcnection record05.wpd [1/4/2005] 1 1 1 1 1 1 1 I 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 FINAL FINAL SEPA. ESA. SHORELINE: 417 -4735 ELECTRICAL LIGHT DEPT CONSTRUCTION R.W PW ENGINEERING 1 FIRE DEPT 1 PLANNING DEPT I BUILDING DATE ACCEPTED BY. DATE ACCEPTED BY: FINAL. INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE DATE YES NO COMMERCIAL DATE ACCEPTED YES I NO 1 1 1 1 1 1 1 1 PREPARED 6/20/06 12 27 09 CITY OF PORT ANGELES ADDRESS 1714 W 7TH ST TENANT NBR GREG MULLIKIN CONTRACTOR OWNER MULLIKIN RENEE /GREGORY PARCEL 06 30 00 0 2 4815 0000 APPL NUMBER 06 00000327 RES ADDITION PERMIT PL 00 PLUMBING PERMIT REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS INSPECTION TICKET INSPECTOR JAMES L LIERLY SUBDIV PHONE PHONE (360) 693 5640 PL1 01 6/20 06 �,L PLUMBING UNDER SLAB TIME 13 00 �1PC". GREG 670 6984 06/19/2006 09 23 AM DYASUMUR COMMENTS AND NOTES PAGE 11 DATE 6/20/06 Lz_ Correction Notice Job Located at (1 ICI r I� Ci Inspection of your work revealed that the following is not in accordance with the codes governing the work in this jurisdiction Qip;, Pas- 7144 tr.Pczre /L' £T 4.5c 1• rz (2, J9/s These corrections must be made and are not to be covered until reinspection is made When corrtions have been made, please call for inspection 12) .vh Date IP BUILDING,. DIVISION CITY OF PORT ANGELES Inspector for Building Division DO NOT REMOVE THIS TAG PREPARED 6/12/06 12 12 44 CITY OF PORT ANGELES INSPECTOR JAMES L LIERLY DATE 6/12/06 ADDRESS 1714 W 7TH ST SUBDIV TENANT NBR GREG MULLIKIN CONTRACTOR PHONE OWNER MULLIKIN RENEE /GREGORY PHONE (360) 693 5640 PARCEL 06 30 00 0 2 4815 0000 APPL NUMBER 06 00000327 RES NEW SFR PERMIT BPR 00 BUILDING PERMIT RESIDENTIAL REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS BL1 01 5/30/06 JLL 5/31/06 DA 05/31/2006 08 28 AM PBARTHOL INSTALL 20 GROUND BL1 02 6/02/06 JLL BUILDING FOUNDATION FOOTING TIME 13 00 6/02/06 AP GREG 670 6984 06/01/2006 08 10 AM DYASUMUR BL2 01 6/12/06 LL INSPECTION TICKET PAGE 10 BUILDING FOUNDATION FOOTING TIME 13 00 GREG 670 6984 05/26/2006 03 26 PM DYASUMUR 06/02/2006 03 19 PM JLIERLY 20 ground BUILDING FOUNDATION WALL TIME 13 00 OVERRIDE TAKEN BY DYASUMUR DATE 06/12/06 TIME 07 52 32 GREG 670 6984 STEMWALL 06/12/2006 07 52 AM DYASUMUR COMMENTS AND NOTES o6. -3 1, 0 `Y- 9 1' Job wired by Electrical Contractor Owner Electrical contractor name License number Purcliaser's i' ailing address I S o_■ r la.(-0-- CA A-4.-- 1 c i 8 P..e A n4-e..- t t■ t r f-e- YN )Oo r City State ZIP fir" I c 14 (1 r^o 5s, IL! cl (l eo.., Telephone number FAX number J 5450 07 b'- b t e 1 s_a_rvlc -e. (�Ot2. i Premises owner's name C cnr I41.t~1 Address of ifdpecttion (7 1 4F w c ity o rd- ty2AA-S Phone number to schedule inspection Owner as defined by RCW 19.28.261 (1) Owner will occupy the structure for two years after this electrical permit is finalized. (2) Owner is required to hire an electrical contractor if above said property is for sale, rent or lease. After reading the above statement, I hereby certify that I am the owner of the above named property or a licensed electrical contractor I am making the electrical instal- lation or alteration in compliance with the electrical laws, N.E.C. RCW Chapter 19.28, WAC. Chapter 296 -46B, The Cit of Port Angeles Municipal Code, and Utility Speci ns. 4 tSigna of ow e 4ectr on X Electrit4l lloa NO LOA CF)ANGES Baseboar KW Furnace KW Heat Pump Ton LAR Fan -Wall KW SAME DAY INSPECTION. CALL BEFORE 7 00 AM 360- 417 -4735 Inspection Date actor or electrical administra or Expiration Date Date: az) 3 administra (0 of card itkons and or subtractions ROUGH -IN Date Appr e By C./ Date AL 3@e-- Co.7O tS 84 Approved By Area, Building or Equipment Inspected 1 V �l ll 1 T r te Date Expires Overhead Service Temp Service 'Underground Service ELECTRIC Approved By WORK PERM" stallation dejcription Commercial Residential "New Altered/Addition 2COA Sic -o r 6DCe //52- L/ 5Q Fr sd� Cash Check ,4 Credit Card Visa Mastercard Discover Card Action Taken Inspes.kion fee Service Information Voltage 2Z� Phasegl 3 Service Size: SAO 4 f Feeder Size: THERMOSTAT L SERVICE Date Approved By e Approved By DITCH FEEDER Date Approved By Electrical Inspector PREPARED 6/02/06 9 54 28 INSPECTION TICKET PAGE 10 CITY OF PORT ANGELES INSPECTOR JAMES L LIERLY DATE 6/02/06 ADDRESS 1714 W 7TH ST SUBDIV TENANT NBR GREG MULLIKIN CONTRACTOR PHONE OWNER MULLIKIN RENEE /GREGORY PHONE (360) 693 5640 PARCEL 06 30 00 0 2 -4815 0000 APPL NUMBER 06 00000327 RES NEW SFR PERMIT BPR 00 BUILDING PERMIT RESIDENTIAL REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS BL1 01 5/30/06 JLL 5/31/06 DA BUILDING FOUNDATION FOOTING TIME 13 00 GREG 670 6984 05/26/2006 03 26 PM DYASUMUR 05/31/2006 08 28 AM PBARTHOL INSTALL 20 GROUND BL1 02 6/02/06 JLL BUILDING FOUNDATION FOOTING TIME 13 00 GREG 670 6984 06/01/2006 08 10 AM DYASUMUR COMMENTS AND NOTES PREPARED 5/30/06 11 29 18 INSPECTION TICKET PAGE 14 CITY OF PORT ANGELES INSPECTOR JAMES L LIERLY DATE 5/30/06 ADDRESS 1714 W 7TH ST SUBDIV TENANT NBR GREG MULLIKIN CONTRACTOR PHONE OWNER MULLIKIN RENEE /GREGORY PHONE (360) 693 5640 PARCEL 06 30 00 0 2 4815 0000 APPL NUMBER 06 00000327 RES NEW SFR PERMIT BPR 00 BUILDING PERMIT RESIDENTIAL REQUESTED INSP DESCRIPTION TYP /SQ COMPLETED RESULT RESULTS /COMMENTS BL1 01 5/30/06 JLL BUILDING FOUNDATION FOOTING TIME 13 00 GREG 670 6984 05/26/2006 03 26 PM DYASUMUR /JO COMMENTS AND NOTES Application Number Application pin number Property Address ASSESSOR PARCEL NUMBER Tenant nbr name Application type description Subdivision Name Property Use Property Zoning Application valuation Owner MULLIKIN RENEE /GREGORY 73 IDEA PL SEQUIM (360) 693 5640 Other struct info Permit Additional desc Permit pin number Permit Fee Issue Date Expiration Date Other Fees Fee summary Permit Fee Total Plan Check Total T•\Polic3 \1102.15R {1/05J Aril WA 98382 Qty Unit Charge Per DRIVEWAY INSTALLATION 74740 170 00 Charged 11/22/06 BASE FEE CITY OF FORT ANGELES PUBLIC WORKS UTILITIES DIVISION 321 EAST 5TH STREET PORT ANGELES, WA 98362 06 00000327 173551 1714 W 7TH ST 06 30 00 0 2-4815 0000 GREG MULLIKIN RES NEW SFR RS7 RESDNTL SINGLE FAMILY 96892 Contractor OWNER TOTAL LOT COVERAGE NUMBER OF STORIES LOT SIZE TOTAL LOT COVERAGE NUMBER OF UNITS Plan Check Fee Valuation Special Notes and Comments Address numbers shall be plainly visible from the street Address numbers shall be a minimum of six inches high and be of contrasting color from the background 04/18/2006 04 44 PM SROBERDS The proposal is for a new sfr in the RS 7 for total lot coverage of 9% No land use issues noted Electrical load calculations and elctrical permits are required connection fee required $410 00 04/17/2006 12 15 PM GMCLAIN Sanitary sewer connection inspection is required by Public Works prior to back fill of ditch 24 hour advance notice is required Construct driveway curb apron and Sidewalks to City Standards No concrete with exposed aggregate allowed in the City road right of way An inspection by Public Works Engineering is required prior to prouring concrete 24 hr notice required prior to pouring concrete Date 5/26/06 11 30 2 00 7000 00 792 00 1 00 00 0 Extension 170 00 STATE SURCHARGE 4 50 Paid Credited Due 170 00 170 00 00 00 00 00 00- 00 Separate Permits are required for electrical work, SEPA, Shoreline, ESA, utilities, private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned for a period of 180 days after the work as commenced, or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. AU provisions of laws and ordinances goveming this type of work will be complied with whether specified herein or not. The granting of a permit does not presum to give autho to v late or cancel the provisions of any state or local law regulating construction or the performance of co ontractor or Authorized Agent Date Signature of Owner (if owner is builder) Date CALL 417 -4807 FOR UTILITY INSPECTIONS. PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT IN A CONSPICUOUS LOCATION. PW UTILITIES (Engineering Division) WATERLINE METER SEWER CONNECTION SANITARY STORM SITE DRAINAGE SITE EROSION CONTROL PARKING SIDEWALK CURB GUTTER DRIVEWAY APPROACH BACK -FLOW DEVICE CONSTRUCTION RW PW/ 417 4807 ENGINEERING FIRE 417 -4653 PLANNING DEPT 417 -4750 BUILDING 417 -4815 T\Policies \1102.1 SR Pm] RESIDENTIAL PERMIT INSPECTION RECORD KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE INSPECTION TYPE DATE ACCEPTED YES NO 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 M 1 1 1 1 1 1 1 1 1 .1 1 1 CONSTRUCTION RW PW ENGINEERING 1 FIRE DEPT 1 1 PLANNING DEPT 1 BUILDING COMMENTS FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE DATE YES NO COMMERCIAL DATE ACCEPTED YES 1 NO 1 1 1 1 1 1 1 1 Application Number Application pin number Other Fee Total Grand Total T•\Policies \1102.15R [1/05) 4 50 174 50 CITY OF PORT ANGELES PUBLIC WORKS UTILITIES DNISION 321 EAST 5TH STREET PORT ANGELES, WA 98362 06 00000327 173551 4 50 174 50 00 0 0 Page 2 Date 5/26/06 00 00 Separate Permits are required for electrical work, SEPA, Shoreline, ESA, utilities, private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned for a period of 180 days after the work as commenced, or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances goveming this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. Signature of Contractor or Authorized Agent Date Signature of Owner (if owner is builder) Date PW UTILITIES (Engineering Division) WATERLINE METER SEWER CONNECTION SANITARY STORM SITE DRAINAGE SITE EROSION CONTROL PARKING SIDEWALK CURB GUTTER DRIVEWAY APPROACH BACK -FLOW DEVICE RESIDENTIAL CONSTRUCTION RW PW/ 417 -4807 ENGINEERING FIRE 417 -4653 PLANNING DEPT 417 -4750 BUILDING 417 -4815 TAPolicies \1102.15R 1 /05) PERMIT INSPECTION RECORD CALL 417 -4807 FOR UTILITY INSPECTIONS. PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT IN A CONSPICUOUS LOCATION. KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE INSPECTION TYPE DATE ACCEPTED YES 1 NO 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 M 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE DATE YES NO COMMERCIAL DATE ACCEPTED YES 1 NO CONSTRUCTION RW PW ENGINEERING 1 FIRE DEPT 1 1 PLANNING DEPT 1 BUILDING COMMENTS Application Number Application pin number Property Address ASSESSOR PARCEL NUMBER Tenant nbr name Application type description Subdivision Name Property Use Property Zoning Application valuation Owner MULLIKIN RENgE /GREGORY 73 IDEA PL SEQUIM (360) 693 5640 Other struct info Permit Additional desc Permit pin number Permit Fee Issue Date Expiration Date CITY OF PORT ANGELES DEPARTMENT OF COMMUNITY DEVELOPMENT BUILDING DIVISION 321 EAST 5TH STREET PORT ANGELES, WA 98362 WA 98382 BUILDING PERMIT RESIDENTIAL 78337 999 25 Qty Unit Charge Per Extension BASE FEE 670 25 47 00 7 0000 THOU BL 50 001 100K (7 00 PER K) 329 00 Special Notes and Comments Address numbers shall be plainly visible from the street Address numbers shall be a minimum of six inches high and be of contrasting color from the background 04/18/2006 04 44 PM SROBERDS The proposal is for a new sfr in the RS 7 for total lot coverage of 9% No land use issues noted Electrical load calculations and elctrical permits are required connection fee required $410 00 04/17/2006 12 15 PM GMCLAIN Sanitary sewer connection inspection is required by Public Works prior to back fill of ditch 24 hour advance notice is required Construct driveway curb apron and Sidewalks to City Standards No concrete with exposed aggregate allowed in the City road right of way An inspection by Public Works Engineering is required prior to prouring concrete 24 hr notice required prior to pouring concrete Other Fees Fee summary Permit Fee Total Charged 11/22/06 06 00000327 173551 1714 W 7TH ST 06 30 00 0 2 4815 0000 GREG MULLIKIN RES NEW SFR RS7 RESDNTL SINGLE FAMILY 96892 Contractor OWNER TOTAL LOT COVERAGE NUMBER OF STORIES LOT SIZE TOTAL LOT COVERAGE NUMBER OF UNITS STATE SURCHARGE 999 25 999 25 Plan Check Fee Valuation Paid Credited Due Date 5/26/06 11 30 2 00 7000 00 792 00 1 00 4 50 00 00 399 70 96892 Separate Permits are required for electrical work, SEPA, Shoreline, ESA, utilities, private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned fora period of 180 days after the work as commenced, or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume e ive authority to violate or cancel the provisions of any state or local law regulating construction or the performance of constru 4 natYr= IV? t Victor or Authorized Agent Date Signature of Owner (if owner is builder) Date T•\Policies \1102_15 building permit inspection record05.wpd [1/4/2005] CALL 417 -4815 FOR BUILDING INSPECTIONS. CALL 417 -4735 FOR ELECTRICAL INSPECTIONS. CALL 417 -4807 FOR PUBLIC WORKS UTILITIES PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT IN A CONSPICUOUS LOCATION. KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE. INSPECTION TYPE DATE ACCEPTED COMMENTS YES 1 NO FOUNDATION: FOOTINGS WALLS FOUNDATION DRAINAGE DOWN SPOUTS PIERS POST HOLES (POLE BLDGS.) PLUMBING UNDER FLOOR SLAB 1 1 1 ROUGH -IN 1 1 WATER LINE (METER TO BLDG) 1 1 1 GAS LINE 1 1 1 FINAL DATE ACCEPTED BY. BACK FLOW WATER 1 1 1 AIR SEAL WALLS /r 4 1 1 1 CEILING' 1 1 1 FRAMING JOISTS GIRDERS 1 1 SHEAR WALL/HOLD DOWNS 1 WALLS ROOF CEILING 1 1 1 DRYWALL (INTERIOR BRACED PANEL ONLY) I 1 1 T-BAR 1 1 1 INSULATION SLAB 1 1 WALL/FLOOR CEILING 1 1 1 MECHANICAL HEAT PUMP FURNACE DUCTS 1 1 GAS LINE 1 1 WOOD STOVE PELLET CHIMNEY 1 1 1 FINAL DATE ACCEPTED BY. COMMERCIAL HOOD DUCTS 1 1 1 MANUFACTURED HOMES FOOTING SLAB 1 1 1 BLOCKING HOLD DOWNS 1 1 1 SKIRTING 1 1 1 1 1 1 PLANNING DEPT SEPARATE PERMIT #'s SEPA. PARKING/LIGHTING 1 1 1 ESA. LANDSCAPING 1 1 1 SHORELINE: FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE RESIDENTIAL DATE YES NO COMMERCIAL DATE ACCEPTED YES 1 NO ELECTRICAL LIGHT DEPT CONSTRUCTION RW PW/ ENGINEERING BUILDING nfl 417 -4735 ELECTRICAL LIGHT DEPT 417 -4807 FIRE 417 -4653 1 PLANNING DEPT 417 -4750 1 417 -4815 1 rnsnection record05.wvd f 1/4/2005] BUILDING PERMIT INSPECTION RECORD 1 1 1 1 1 1 1 1 1 1 1 1 CONSTRUCTION RW PW ENGINEERING 1 FIRE DEPT 1 PLANNING DEPT 1 BUILDING 1 1 1 1 1 1 1 1 1 T•\Policies \1102_15 building permit inspection record05.wpd [1/4/2005] CITY OF PORT ANGELES DEPARTMENT OF COMMUNITY DEVELOPMENT BUILDING DIVISION 321 EAST 5TH STREET PORT ANGELES, WA 98362 Page 2 Application Number 06 00000327 Date 5/26/06 Application pin number /73551 Plan Check Total 399 70 399 70 00 00 Other Fee Total 4 50 4 50 00 00 Grand Total 1403 45 1403 45 00 00 Separate Permits are required for electrical work, SEPA, Shoreline, ESA, utilities, private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned for a period of 180 days after the work as commenced, or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. Signature of Contractor or Authorized Agent Date Signature of Owner (if owner is builder) Date CALL 417 -4815 FOR BUILDING INSPECTIONS. CALL 417 -4735 FOR ELECTRICAL INSPECTIONS. CALL 417 -4807 FOR PUBLIC WORKS UTILITIES PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT IN A CONSPICUOUS LOCATION KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE. INSPECTION TYPE DATE ACCEPTED COMMENTS YES 1 NO FOUNDATION: FOOTINGS4:6644fith WALLS FOUNDATION DRAINAGE DOWN SPOUTS PIERS POST HOLES (POLE BLDGS.) PLUMBING UNDERFLOOR /SLAB ROUGH -IN WATER LINE (METER TO BLDG) GAS LINE BACK FLOW WATER AIR SEAL WALLS CEILING FRAMING JOISTS GIRDERS SHEAR WALL/HOLD DOWNS WALLS ROOF CEILING DRYWALL (INTERIOR BRACED PANEL ONLY) T -BAR INSULATION SLAB WALL FLOOR CEILING MECHANICAL HEAT PUMP FURNACE DUCTS GAS LINE WOOD STOVE PELLET CHIMNEY COMMERCIAL HOOD DUCTS MANUFACTURED HOMES FOOTING SLAB BLOCKING HOLD DOWNS SKIRTING PLANNING DEPT SEPARATE PERMIT #'s PARKING/LIGHTING LANDSCAPING RESIDENTIAL ELECTRICAL LIGHT DEPT BUILDING PERMIT INSPECTION RECORD 1 6/2/6 Lytle. I I e/,-o f�4 1 747 (A.- 1 1 1 1' 1 1 1 1 l%./- I v 1 FOR___IJ 1 FINAL(_2 eCR DATE`S ACCEPTED BY. 1,2"/'3%o7 v 1 1 1 1 1 1 1 //3/o7 l A-- 1 1 is 2 L2- 1 1 1 1 1 In ✓r/ /ti'7 L/ 6-L- 1 1 1 1 1 1 1 3 62_ 1 1 1 FINAL 0 J DATE "3"- ACCEPTED BY. 1 1 1 1 1 1 1 1 1 1 1 I I SEPA. 1 1 ESA. 1 1 SHORELINE: FINAL. INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE DATE YES NO COMMERCIAL DATE ACCEPTED YES 1 NO 417 -4735 ELECTRICAL LIGHT DEPT CONSTRUCTION R.W PW/ CONSTRUCTION R.W ENGINEERING 417 -4807 PW ENGINEERING FIRE 417 -4653 I 1 I I FIRE DEPT PLANNING DEPT 417 -4750 1 1 1 1 PLANNING DEPT BUILDING 417-4815 IO ?)'O2' 13 1 I BUILDING anc —a nn/ c1 1 1 1 1 1 1 1 1 1 Applicant or Agent: Owner c re. Mt,>s. Y1 Address: 7 3 Z d ea. I,a. Architect /En PLANNING USE ONLY 'I':t 131dgPennitform.wpd Applicant: irg BUILDING PERMIT APPLICATION Fill out COMPLETELY and in INK. Your application and site plan MUST B COMPLETE to be accepted for review if you have any questions, call PERMITS (360) 417 -4815 FAX(360)417 -4711 Contractor 0wsve r State License Address: PROJECT ADDRESS ESA/Wetland(s) Yes No SEPA Checkhst required? Yes No Other Phone aat (o�, 4 City u.tw. Zip 9,41 Phone: Phone: Exp TYPE OF WORK. SIZE/VALUATION Residential g New Constr Re -roof tS o e� 52. SF $_76../i9 /SF Multi- family Addition Move Garage6c. 1 SF $_'.2./3i5 /SF Commercial Remodel Q Demohtion Deck SF /SF Repair Sign Other TOTAL VALUATION BRIEF DESCRIPTION OF THE PROJECT ESG p 1 Pt' L U E_ A 1 SX4 Li Two to 124 oon sa4rwt E. 4I1054 M144 S'f a 2y c9yrg� t� COMMERCIAL/RESIDENTIAL. Occupancy Group No of Stories. 2 Lot Size: 1006 Er Existing Sq Ft. Total lot coverage 8 FOR OFFICIAL USE ONLY Date Rec. 4 -7- DEC Pennit J Date Approved: I Date Issued: Zip Phone: City 111 ■i ti'+ For A-v%0,41.tes ZONING R S LEGAL DESCRIPTION Lot: Block: 2.44 8 Subdivision. Tawnsiwi a Pat+ Ain CLALLAM COUNTY PARCEL NUMBER. 0 (0 2 Z0015 02-4 et IS 0000 Occupant Load. Construction Type. Proposed Sq Ft. 1 TOTAL Sq Ft. APPROVALS PLAN BLDG DPWU FIRE OTHER. VALUATION OF CONSTRUCTION In all cases, a valuation amount must be entered by the applicant. This figure will be reviewed and may be revised by the Buildmg Division to comply with current fee schedules. Contact the Permit Coordinator at 417 -4815 for assistance. PLAN CHECK FEE. IF a plan check fee is due it must be submitted at the time the buildmg permit application and construction plans are submitted. All other permit fees are due at the time f permit issuance. EXPIRATION OF PLAN REVIEW If no permit is issued within 180 days of the date of application, the application will expire. The Building Official can extend the time for action by the applicant up to 180 days upon written request by the applicant (see Section R105.3.2 of the International Buildmg/Residential Code, 2003) No application can be extended more than once. I hereby certify that I have read and examined this application and know the same to be true and correct. I am authorized to apply for this permit and understand that it is my responsibility to determine what permits are required not the City`s, and that l must obtain such permits prior to work. Date: 6 4-05 -0CD 7 o.1 -,6.a PA/ Cie *ins Me% EP Application Number Pin number Property Address ASSESSOR PARCEL NUMBER Application description Subdivision Name Property Use Property Zoning Application valuation Owner FRANTZ ROBERT JENNIFER 1318 WEST 5TH DT PORT ANGELES WA 98363 (360) 452 4305 TAPLANNING\FORMS \1102.15 [11/14/2003) CITY OF PORT ANGELES DEPARTMENT OF COMMUNITY DEVELOPMENT BUILDING DIVISION 321 EAST 5TH STREET PORT ANGELES, WA 98362 04 00000911 845972 1714 W 7TH ST 06 30 00 0 2 4815 0000 ELECTRICAL ONLY RS7 RESDNTL SINGLE FAMILY 0 Contractor Date 10/06/04 SHAMP ELECTRICAL CONTRACTING PO BOX 383 PORT ANGELES WA 98362 (360) 452 1689 Permit ELECTRICAL TEMPORARY SERVICE Additional desc TEMP SVC Permit Fee 42 20 Plan Check Fee 00 Issue Date 10/06/04 Valuation 0 Expiration Date 4/05/05 Qty Unit Charge Per 1 00 42 2000 ECH EL -TEMP SRV 0 60 SRV FDR Fee summary Charged Paid Credited Due Permit Fee Total 42 20 42 20 00 00 Plan Check Total 00 00 00 00 Grand Total 42 20 42 20 00 00 Extension 42 20 Separate Permits are required for electrical work, SEPA, Shoreline ESA, utilities, private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned for a period of 180 days after the work as commenced or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. Signature of Contractor or Authorized Agent Date Signature of Owner (if owner is builder) Date CALL 417 -4815 FOR BUILDING INSPECTIONS. CALL 417 -4735 FOR ELECTRICAL INSPECTIONS. PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT IN A CONSPICUOUS LOCATION KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE. INSPECTION TYPE DATE ACCEPTED COMMENTS FOUNDATION: FOOTINGS 1 WALLS 1 FOUNDATION DRAINAGE/DOWN SPOUTS 1 1 ELECTRICAL (LIGHT DEPT) SEPARATE PERMIT ROUGH -IN I 1 PLUMBING UNDER FLOOR SLAB 1 1 ROUGH -IN 1 1 WATER LINE (METER TO BLDG) 1 1 GAS LINE 1 1 BACK FLOW WATER 1 AIR SEAL WALLS 1 CEILING 1 FRAMING JOISTS GIRDERS 1 SHEAR WALL/HOLD DOWNS 1 1 WALLS ROOF CEILING 1 DRYWALL (INTERIOR BRACED PANEL ONLY) 1 1 T -BAR 1 INSULATION SLAB 1 1 WALL FLOOR CEILING 1 1 MECHANICAL HEAT PUMP 1 1 GAS LINE 1 1 WOOD STOVE PELLET CHIMNEY 1 1� HOOD DUCTS 1 PW UTILITIES SITE WORK (Engineering Division) SEPARATE PERMIT #'s: WATERLINE METER 1 SEWER CONNECTION 1 SANITARY STORM 1 1 PLANNING DEPT SEPARATE PERMIT #'s PARKING/LIGHTING LANDSCAPING RESIDENTIAL ELECTRICAL LIGHT DEPT CONSTRUCTION R.W PW/ ENGINEERING 417 -4807 FIRE 417 -4653 PLANNING DEPT 417 -4750 BUILDING 417 -4815 T•\PLANNING\FORMS \1102.15 11/14/2003] BUILDING PERMIT INSPECTION RECORD YES 1 NO SEPA. ESA. SHORELINE. FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE DATE YES NO COMMERCIAL DATE ACCEPTED YES 1 NO 417 -4735 ELECTRICAL LIGHT DEPT CONSTRUCTION R.W PW ENGINEERING 1 FIRE DEPT PLANNING DEPT 1 BUILDING 1 1 1 1 1 I I I I PORT. �11 Application Number Pin number Property Address ASSESSOR PARCEL NUMBER Application description Subdivision Name Property Use Property Zoning Application valuation FRANTZ ROBERT JENNIFER 1318 WEST 5TH DT PORT ANGELES WA 98363 (360) 452 4305 Fee summary T•\PLANNING\FORMS \1102.15 [11/14/2003] CITY OF PORT ANGELES DEPARTMENT OF COMMUNITY DEVELOPMENT BUILDING DIVISION 321 EAST 5T1-1 STREET PORT ANGELES, WA 98362 04 00000911 845972 1714 W 7TH ST 06 30 00 0 2 4815 0000 ELECTRICAL ONLY RS7 RESDNTL SINGLE FAMILY 0 Owner Contractor SHAMP ELECTRICAL CONTRACTING PO BOX 383 PORT ANGELES WA 98362 (360) 452 1689 Permit ELECTRICAL TEMPORARY SERVICE Additional desc TEMP SVC Permit Fee 42 20 Plan Check Fee 00 Issue Date 10/06/04 Valuation 0 Expiration Date 4/05/05 Qty Unit Charge Per Extension 1 00 42 2000 ECH EL -TEMP SRV 0 60 SRV FDR 42 20 Charged Paid Credited Due Date 10/06/04 Permit Fee Total 42 20 42 20 00 00 Plan Check Total 00 00 00 00 Grand Total 42 20 42 20 00 00 Separate Permits are required for electrical work, SEPA, Shoreline, ESA, utilities, private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned for a period of 180 days after the work as commenced, or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume td give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. Signature of Contractor or Authorized Agent Date Signature of Owner (if owner is builder) Date BUILDING PERMIT INSPECTION RECORD CALL 417 -4815 FOR BUILDING INSPECTIONS. CALL 417 -4735 FOR ELECTRICAL INSPECTIONS. PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT IN A CONSPICUOUS LOCATION KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE. INSPECTION TYPE DATE ACCEPTED COMMENTS YES 1 NO FOUNDATION: FOOTINGS 1 1 WALLS 1 11 FOUNDATION DRAINAGE/DOWN SPOUTS 1 1 I ELECTRICAL (LIGHT DEPT) SEPARATE PERMIT ROUGH -IN 1 1 PLUMBING UNDERFLOOR /SLAB 1 ROUGH -IN 1 I WATER LINE (METER TO BLDG) 1 1 1 GAS LINE 1 I BACK FLOW WATER I AIR SEAL WALLS M N II CEILING M I I FRAMING JOISTS GIRDERS 1 1 I SHEAR WALL/HOLD DOWNS 1 1 WALLS ROOF CEILING I 1 DRYWALL (INTERIOR BRACED PANEL ONLY) M 1 T -BAR f 1 INSULATION SLAB I II WALL FLOOR CEILING 1 1 1 MECHANICAL HEAT PUMP 1 1 I I I GAS LINE I 1 1 WOOD STOVE PELLET CHIMNEY 1 1 HOOD DUCTS 1 PW UTILITIES SITE WORK (Engineering Division) SEPARATE PERMIT #'s: WATERLINE METER 1 1 1 SEWER CONNECTION I 1 I SANITARY I I STORM I 1 1 PLANNING DEPT SEPARATE PERMIT #'s PARKING/LIGHTING 1 I LANDSCAPING 1 1 I RESIDENTIAL ELECTRICAL LIGHT DEPT 417 -4735 SEPA. ESA. SHORELINE. FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE DATE YES NO COMMERCIAL ilf/‘/IeV AekleC CONSTRUCTION R.W PW/ CONSTRUCTION R.W ENGINEERING 417 -4807 PW ENGINEERING FIRE 417 -4653 1 I I I FIRE DEPT PLANNING DEPT 417 -4750 1 1 1 1 PLANNING DEPT BUILDING 417 -4815 M I I 1 BUILDING T• \PLANNING\FORMS\ 1102.15 111/14/2003] ELECTRICAL LIGHT DEPT DATE 1 1 1 I 1 1 1 1 1 ACCEPTED YES 1 NO 10/05/2004 14 16 FAX Owner or Elec. Contrac cr Agent. ,t_1[.tJ' Property Owner 'TIZAN7-. Address. \fl GO Electrical Contractor: .51' 1110 k_14 7 Address: I INSTALLATION WIRED 13Y i l OWNER ELECTRICAL CONTRACTOR Credit Card Holder Nam' Li.9 K )4 V•.J 3 1-11911 Billing Address....al( il i jtY'� y r �?t,� f City' C �i- I.� j iv Credit Card Number ' _ Exp. Date: PROJECT ADDRESS. TYPE OF WORK. Check all that apply Residential (I Multi amity El Commercial 0 Mobile Home Sq Ft t'1 Remote Meter u D tached garage fl Hot Tub 0 Swim Pool 0 Septic Pump Number of Circuits added r altered. DESCRIPTION OF THE EL CTRICAL PROJECT AA ac A,a)e taft-of /A »a,).) b e-17 I-( MA--i y Electrical Heat L ad Addition and or Subtractions Baseboard r 1 Fumace 0 Heat Pump 1 :3 Fan -wall KW TON LRA KW C /ELECTRICALPERMITAPPLICATION ELECTRICAL PERMIT APPLICATION The Electrical Permit Application must be filled out completely. Please type or reprint in ink. If you have any questions, please call (360) 4174735 Fax number (360) 417 -4711 `jpP F IP -iy 'LL on; }CT L Phone: 1 62- lfC rl�l s E Cit A ter- t t'!(FLt IEiC' Lice W 1 I_'u; City 4 /4-K, b ril LL u 19Iq Lk) M 0 New Credit Card Holder's Signature Owner or Elec. Cont. Signature' 127Alteratlon /Addition e2#=- °i5t1 O Overhead Service rl Temp Service 0 Underground Service y r Phone* f ti 0 LOW Voltage 0 Telecom 0 Sign POP 4»1(.!AL USE ONLY Umette' Penn 0 Date Aprroved Datt 1r.ued Zip, VISA. X MC. (-4AJ6 1 Service Information Voltage: Phase: ri 1 u 3 Service Size Feeder Size. I hereby certify that have read and examined this application and know that same to be true and correct, and 1 am authorized to apply for this permit. I understand it is not the City's legal responsibility to determine what permits are required, it remains the applicants responsibility to determine what permits are required and to obtain such Date' to c j bL 0 \5 DA Date f� 001 /00e Zip: Phone. L L Zip: PERMIT FEE -^0 Residence Structural Design for Greg Mullikin 73 Idea Place Sequim, WA 98382 1714W 7th Ave Port Angeles, WA 98363 S aoZ -vim QRES 0- 4 SEASONS ENGINEERING, INC 619 SOUTH CHASE STREET PORT ANGELES, WA 98362 City of Port Angeles Building Department 321 East Fifth St. Port Angeles, WA 98362 Subject: Scope of Engineering for Structural Design Greg Mullikin 73 Idea Place Sequim, WA 98382 Enclosed is the structural design of the Residence for Greg Mullikin May 22, 2006 At this time, portions of this structure that have been reviewed by the engineer include 1 Lateral Forces 2. Beams and Headers 3. Foundation Please give me a call if you need any additional information. Sincerely Donna J Petersen P.E. Structural Design Greg Mullikin 73 Idea Place Sequim, WA 98382 DESIGN CRITERIA ELEVATION LESS THAN 625 FT SNOW LOAD GROUND= 25 PSF SNOW ROOF 25 PSF LIVE LOAD 40 PSF (FLOOR) DEAD LOAD 10 PSF (FLOOR) DEAD LOAD =10 PSF (ROOF) DEAD LOAD 7 PSF (CEILING) 3 SEC GUST, Vas 100 MPH EXPOSURE C SEISMIC SPECTRAL. ACCELERATION Ss =1.50, S1 =.60 SEISMIC SITE CLASS D SEISMIC USE GROUP I SOIL BEARING 1500 PSF REFERENCES (1) (3) (4) (5) (6) (7) DESIGN STRESSES DOUGLAS FIR/LARCH #2- 2 4 x Fb= 900 PSI Fv 95 PSI E= 1.6 (10) PSI DOUGLAS FIR/LARCH #1- 2 4 x Fb 1200 PSI F 95 PSI E= 1.8 (10) PSI HEM FIR #2- 2 4 x F 850 PSI F 75 PSI E= 1 3 (10) PSI GLU -LAM BEAMS 24F -V4 Fb= 2400 PSI (T) BOTTOM Fb= 1850 PSI (T) TOP F 165 PSI E= 1.8 (10) PSI INTERNATIONAL BUILDING CODE 2003 INTERNATIONAL RESIDENTIAL CODE 2003 TIMBER CONSTRUCTION MANUAL 3RD ED by AITC CONNECTORS FOR WOOD CONSTRUCTION by SIMPSON STRONG -TIE WESTERN WOODS USE BOOK by WESTERN WOOD PRODUCTS ASSOCIATION MAY 1996 NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION 1997 ROSBORO -APA WOODCAD, VERSION 1 1 by ROSBORO GLULAM RESOURCES 2000 RISA -2D RAPID INTERACTIVE STRUCTURAL ANALYSIS 2- DIMENSIONAL VERSION 5.5 2001 General Notes 1 Ground snow Toad 25 PSF roof snow load 25 PSF 2. Maximum soil bearing capacity =1500 PSF 3. Seismic Zone D2. 4. Wind, VFM 80 MPH, 3 second gust, V38 100 MPH, Exposure 'C' 5. Notations on drawing relating to framing clips, joist hangers and other connecting devices refer to catalog numbers of connectors manufactured by the Simpson Strong -Tie Company, San Leandro, CA. Equivalent devices by other manufacturers may be substituted, provided they have ICBO approval for equal load capacities. 6. Roof Trusses: Trusses shall be designed by the manufacturer and design calculations shall be submitted for approval prior to fabrication. Each wood truss shall carry a grading stamp. Top chord members shall be sized to accommodate roof snow load and appropriate snow drifts as noted in the IBC. No field modification of trusses will be allowed without the engineer's approval. Live load truss deflection shall be limited to L/360. Total load deflection will be limited to L/240. 7 Girder trusses shall be attached to wall framing with Simpson LGT2, minimum 2000 pounds uplift, or equal. 8. Contractor shall provide temporary bracing and shoring for the structure and structural components until all final connections have been completed In accordance with the plans. 9. Contractor shall be responsible for all the required safety precautions and methods, techniques, sequences or procedures required to perform his work. 10. Contractor initiated changes shall be submitted in writing to the structural engineer for approval prior to fabrication or construction. 11 Drawings indicate general and typical details of construction, where conditions are not specifically indicated but are of similar character to details shown, similar details of construction shall be used. 1 All materials and workmanship shall conform to the requirements of the drawings, specifications, and the 2003 International Residential Code. 2. Concrete shall attain a 28 day strength of F'c= 2500 psi, 5 1/2 sacks of cement per cubic yard of concrete. 3. Reinforcing steel shall conform to ASTM A615 -76A, Grade 40, fy= 40,000 psi. 4. Reinforcing steel shall be detailed (Including hooks and bends) in accordance with 30 bar diameters or 2' -0' minimum. Provide corner bars in all wall intersections. Lap corner bars 30 bar diameters or 2' -0' minimum. 5. Lap adjacent mats of welded wire mesh one full mesh at sides and ends. 6. No bars partially embedded In hardened concrete shall be field bent unless specifically so detailed or approved by the structural engineer 7 Concrete protection (cover) for reinforcing steel shall be as follows: Footings and other unformed surfaces: earth face 3' General Concrete Notes (The Following apply unless shown on the plans) Formed surfaces exposed to earth, walls below ground, or weather' #6 bars or larger 2' #5 bars or smaller 1 -1/2' Walls interior face 3/4' 8. Footings shall bear on solid unyielding natural earth free of organic material Single story structures Two story structures Three story structures 12' below original grade 18' below original grade 24' below original grade 9. Slabs shall be placed upon compacted granular fill, 2' minimum thickness. Wood Framing Notes (The Following apply unless shown on the plans) 1 All wood framing details not shown otherwise shall be constructed equal to or better than the minimum standards of the 2003 I.R.C. 2. Minimum nailing requirements: Unless otherwise noted, minimum nailing shall be in accordance with Table R602.3(1) of the 2003 I.R.C. 3. All structural framing lumber such as 2x_ Joists, and rafters to be Douglas Fir No. 2, Spruce /Pine /Fir No. 2, or Hem /Fir No. 2 kiln dried. 4. All 2x_ studs and blocking to be Douglas Fir construction, Spruce /Pine /Fir construction, or Hem /Fir construction grade. 5. All structural posts to be Douglas Fir No. 2. 6. All structural headers to be 4x, Douglas Fir No. 2. 7 All Glu -lam beams to consist of Douglas Fir kiln dried 24F -V4 standard grade unless noted otherwise on plans. 8. All 2x framing lumber exposed to weather and/or moisture shall be Hem -Fir No.2, pressure treated in accordance with the American Wood Preservers Association standard for above ground use. 9. All 4x and 6x structural lumber exposed to weather and/or in ground contact shall be Hem -Fir No.2, pressure treated In accordance with the American Wood Preservers Association standard for ground contact use. 10. Framing connectors, nails, bolts, and other fasteners in contact with pressure treated wood shall have the following finishes: Wood Treatment I 1 CCA-C and DOT Sodium Borate (SBX) I ACQ-C, ACQ -D, CBA -A, CA -B, Other Borate (Non -DOT) Steel Ammoniacal Copper Zinc Arsenate (ACZE) I and other pressure treated woods. Finish Galvanized, 0.60 oz/ft` Post Hot -Dip Galvanized, ZMAX galvanized, 1.85 oz/ft or SST300- Stainless Steel SST300- Stainless Steel 11 When using Stainless Steel or hot -dip galvanized connectors, the connectors and fasteners should be made of the same material. Stainless Steel fasteners shall not be use in applications where contact with Galvanized and Post Hot -Dip Galvanized metals will occur 12. Individual members of built -up posts and beams shall each be attached with 16d spikes at 12' o.c. staggered. 13. All columns in framed walls to be well nailed into adjacent framing in order to resist lateral movement. 14. Provide solid blocking for wood columns and multiple studs through floors to supports below. 15. Provide 4x10 headers, or double 2x10 headers over and double studs each side of all openings in stud bearing walls not detailed otherwise. 16. Provide 4x8 headers, or double 2x8 headers over and double studs each side of all openings in non structural stud walls not detailed otherwise. 17 At joist areas: Provide solid blocking at bearing points and at intermediate bearing locations. Provide double joists under all load bearing partitions. Provide double joists each side of openings unless detailed otherwise. 18. Provide double joist headers and double joists each side of all openings in floors and roofs unless detailed otherwise 19. Toenail joists to supports with 2 -16d nails, 2 -10d box nails for TJI joists. 20. Attach joists to flush headers and beams with Simpson 'lP series metal joist hangers to suit the joist size. 21 All wood stud walls shall have lower wood plate attached to wood framing below with 16d nails at 12' o.c. staggered, unless otherwise noted in the shearwall schedule. 22. Plywood roof and floor sheathing unless otherwise noted on plan shall be laid up with face grain perpendicular to supports and nailed with 8d nails 6' o.c. to framed panel edges and over stud walls shown on the plans 12' o.c. to intermediate supports. Provide approved plywood clips 16' o.c. at unblocked roof sheathing edges. Provide solid blocking at lines of support at floors. Toenail blocking to supports with 16d 12' o.c. unless otherwise noted in the shearwall schedule. 23. Provide continuous solid blocking at mid- height of all stud walls over 10' in height unless wall is blocked per shear wall note. 24. Plywood wall sheathing for noted shear walls shall have solid blocking at all sheathing panel edges. See shear wall schedule for further notes. 2 9 s A 4'-fr 4' ti 12' 1221 SH 1226 SH BP -r \I -4 -i 2- P 1 z 4' A 1226 SH 1226 311 1226 SH 1226 SH A BP BP 4' 4' 221 SH 4' 10' -8 L 4' L L r_. I 1226 SH 1226 SH 1226 SH 1220 SH 1226 SH 12' 2 0 122P SH 4' t7 p 8 3 1226314 1226 311./BP\ A 4' 3 4 r X 2003 IBC WIND ANALYSIS BUILDING DESCRIPTION FIRST FLOOR SECOND FLOOR ROOF HEIGHT AVERAGE HEIGHT OF BUILDING A 1 1.8 1 3 WIND EXPOSURE IC WIND SPEED 1100 MPH ROOF PITCH 1 61 P ijwPs3o P ?.IwPs3o AREA A, p s30 AREA B, ps30 AREA C, ps30 AREA D, ps30 AREA E, ps30 AREA F ps30 AREA G, ps30 AREA H, ps30 E oh G oh COMPONENTS ZONE 1 50sgft ZONE 2, 50 sqft ZONE 3, 50sgft EAVES Z2 AREA WIDTH LENGTH LEAST DIM 1 8 1 44I 181 10: 2 20 3 121 26.571 MULLIKIN LATERAL.xls 2A 6.0 I 1I-C1 P LC1,P LC2,Ps30 1.29 1 19.9 25.69 19.9 1.29 1 3.2 4 13 3.2 1.29 1 144 18.59 144 1.29 1 3.3 4.26 3.3 1.29 1 -8.8 11.36 3.4 1.29 1 12 15.49 -6.6 1.29 1 -6.4 -8.26 -0.9 1.29 1 -9.7 12.52 -4.2 1.29 1 16.5 -21.30 1.29 1 14 18.07 44 1.29 1 A 5,4' 19.88 1.29 1 -23, 3 -30.07 1.29 1 -36 -46.47 1.29 1 =33;5 -43.24 1 2003 IBC SEISMIC ANALYSIS S1 Ss SITE CLASS Fv Fa Sm1 Sms Sd1 Sds SEISMIC USE GROUP SEISMIC DESIGN CATEGORY LC2,P RESPONSE MODIFICATION FACTOR 1 25.69 SEISMIC BASE SHEAR COEFFICIENT 4.13 CONNECTION OF SMALL ELEMENTS 18.59 SHEAR COEFFICIENT= 4.26 HORIZONTAL DIAPHRAGMS -4.39 SHEAR COEFFICIENT= -8.52 BEARING AND SHEAR WALL 1 16 OUT OF PLANE WALL FORCES -5.42 SHEAR COEFFICIENT= -9 881 59.271 LONGEST TRUSS 2 FT OC -20 071 -240 9IEAvEs 36.471 'ROOF DEAD LOAD 33.241 1331TRUSS UPLIFT HURRICANE CLIP SIMPLIFIED BASE SHEAR 0.50 1.25 D 1.50 1.00 0.75 1.25 0.50 0.83 1 D 6 1/2 0.154 0.111 0.1667 0.3333 16.51 -21.30 MASONRY AND CONCRETE OUT OF PLANE 141 18.07 SHEAR COEFFICIENT= 1 0.6667 18 2 10 433 H10 PRESCRIPTIVE PATH BRACED WALL LINES CONTR+QJL9)I(IMUMERA1(RIOR WALLS LATERAL IAW IRC 602 1 (ROOF& CEILING DL= I 15IPSF I MINIMUM ITOTAL WALL (LEVEL (METHOD I HEIGHT (LENGTH INTERIORICONT (MAX %WALL TABLE TABLE 'TABLE BRACE LENGTH' BRACING LINE I 13 OR 5 1 FT 1 FT WALL ?(WIDTH (OPENING REQ'D R602.10.5 R602.1QR301.2.2.4 PANEL REQUIRIIPROVIDED 1 1 1 1 1 (HEIGHT WIDTH 11 :1I: :312 81 18 NI _24: 0.25 0.8 1 1 10 4 8 21 11 ......lit 18 xI _241` 8 0.4 1 0.96 1 4.0 7 I 8 3I 11 131 18 :Y1 16.1 8 0.4 1 0.64 1 4.0 5 8 41 11 31 81 18 NI. 161` 5 0.25 0.8 1 1 2.0 4 8 5 1: :11 81 44 NI 181- 2 :5 0.25 0.8 1 1 2.0 9 12 61 11: 31 44 :NI; 18! 2;5 0.25 0.8 1 1 2.0 9 12 11. .21 91 18 NI.. 241;,.. 8 0.55 1 1 1 3.3 10 8 2I. :2I `51. 9I 18 i :YI ,:241:.......,. .9 0.75 1 0.96 1 4.0 13 16 31. :21r 's1' 91" .18 Y 16I, 19I 0.75 1 0.64 11 4.0 9 16 4 ._'2I _.3I' 91'. t8 16i 0,55 0.8 1 11 2.3 8 8 N 51 ..2I 31 -91 44: NI 181. 2:51 0.55 0.8 1 11 2.3 19 20 61 .21 31 9I 44 ,:N1,:..181_, 2.51 0.55 0.8 1 11 2,3 19 20 WALL TRIB AREA A B C D WIND Main 1 WALL SHEAR FLOOR 1 PANEL PLF 1 213.2 A 479.7 I B 1 479.7 SEISMIC SHEAR PLF 52.3 117 7 117.7 9 1 MAIN LATERAL FORCE RESISTING SYSTEM WIND LOADS (AREARPRESSURE)ILENGTH SHEAR WIDTH 1 HEIGHT PS FORCE LENGTH 1 SHEAR TRIB FT I FT PSF LBS FT IPLF AREA 6..0. ;1' 13.5 25.69 1 (ROOF 4.13 1 IFLOOR 6.0 I 18.59 1 (WALL 6.0 5.0,_ 4.26 3837.8 18 'I 213.2 IETC. PERFORATED SHEAR WALL DESIGN 1 1 1 I I 1 OVERALL HEIGHT 1 WIDTH FT 1 FT 9 1 18 .4 WIDTH 1 DL FT I PSF .'12.0 ;17 17.0 I 1 SEISMIC LOADS I 1 SHEAR COEFF 0.154 SHEAR LBS 941.5 MINIMUM PIER 1 1 I RESISTANC DESIGN HEIGHT I WIDTH 11AX OPENINI OF WALL I OF FUIIDJUSTMENI SHEAR FT 1 FT !HEIGHT (FT. )J HEIGHT PHT SH1 FACTOR PLF I, 1 1 1 1 •1- 4I I 0 1.4:00 :1 1.00 0 1 1.001 342.7 1.00 1 342.7 1 SHEAR PLF 52.3 (WALL DL I. ..10 1 SHEAR I TRIB WALL 1 ROOF TYPE FT 2 1 3 2 1 3 ROOF DL 17 TRIB FLOOR FT FLOOR DL UPLIFT HOLD LBS. DOWN 4148.3 PHD5 1 4148.31 PHDS 1 Mark Sheeting Fastener spacing 0 all edges (Blodced) 8dO6'0C OR 15 GA 04"OC 7/16' OS8 7/16 X 8d 0 4" OC OR 15 GA 03" OC 8d 0 3" 00 OR 15 GA 0 2 -1/2" oC 1/2" CDX 10d O 3" OC plywood 1/ X 10d 0 2" OC 1/2" 0116 5d COOLER 0 4" OC both sides GR 5d GW9 0 4 GC 5/8 OMB 6d COOLER or OC both sides 6d 04804 "OC Notes: z 4. 5. 6. 7 SHEAR WALL SCHEDULE 1 7 bottom plate nailing Qe Intermediate framing nail spacing 8d or 00 for stud framing 024" 8d O r2 for stud framing 016" 10d 0 roc for stud flaming 0 24" 10d 0 12 OC for stud framing 016" 10d06 "OC for stud flaming 0 24" 10d 0 12 OC for stud framing 0 16" 5d coder 0 4" OC 5dGVB04 "OC 6d coder 0 4" OC 6d GIB 0 4" OC 1. ALL NAILS SHALL BE GALVANIZED BOX NAILS OR 8d common 0.131 dia X 2-1/2"mln. 10d common 0.148dia X 3 "mki. 8d box -0.113 dla X 2 -1/2 "min. 10 box 0.128 "dia X 3 min. 15 GA. staple 0.072'dia X 1 -1/2" min ALL SHEAR PANELS SHALL BE BLOCKED. Framing b size g for O stud framing 024" 8d 0 12" OC for stud framin 0 16" ��ud fr 024" 8d 012 "OC for stud taming 0 16" .3x or DBL2x 3x or DBL.2x 3x or DBL2x 2x 2x NAILS TO BE DRIVEN FLUSH WITH SHEATHING. DO NOT OVER DRIVE NAILS doubled st l Anchor Bolts Sheeted Sheeted (Sheeted ISheeted one side both sides one side both sides 240 PLF 2 -16d 0 2 -16d 0 5/8 5/8" X10" 480 PLF 12"0C 8 "OC 048 ac. 030" 0.0 350 PLF 2. 3, 5, 6 2 -16d 2 -16d 0 5/8"X10" 5/8" X10" 700 PLF 010 "0C 5'OC 040" 0.C. 020' 0.C. 49O 2 6 2 -16d 2 -16d 0 5/8"X10" 5/8 07"OC 3- 1/2'0C 0 0 L4'o.C. 600 PLF 2 -16d 2 -16d 0 5/8" X10" 5/8" X10" 1200 PLF 0 6 3 "0C 0 24" O.C. 012" 0.C. 770 PLF 3 -16d 3 -16d 0 5/8" X10" 5/8' X10" 1 PLF 0 6 3 "0C our 0.0 O 9" 0.C. 2 -16d 0 5/8 "X10' 12"0C 048" 0.c 2 -16d 0 5/8" X10" 10OC 0 36"0.C. COMMON NAILS, FA,SiER ASH dia MEET X 1 d ".LQ NG CR11ER1A: 5 5d d GGMB 0. X.1 -5 8 8" min. 6d coder —0.092 dia X 1-718 min. 6d 011B 0.092dia X I-7/8" min. 16.1 common 0.162 "dia X 3-1/2" min. e0•11111 Mel xlumum Wree allocable shear 300 PLF 375 PLF 3, 6 PROVIDE APA RATED SHEATHING PLYWOOD OR 058 APA RATED SIDING 303 OF INNER SEAL OSB RATED PANEL SIDING ON ALL EXTERIOR WALLS AND NAIL PER NOTE 1. SPECIFIED SHEATHING AND SIDING PANEL EDGES SHALL BE BACKED WITH 2" OR 3" FRAMING PER THE TABLE) INCLUDING FOUNDATION SILL PLATES, VERTICAL FRAMING, AND BLOCKING. PANELS MAY BE INSTALLED EITHER HORIZONTALLY OR VERTICALLY (SEE NOTE 4 FOR EXCEPTION). NAILS SHALL BE STAGGERED FOR 3" FRAMING. 7/16' 058 MAY BE SUBSTITUTED FOR 1/2" COX PLYtI00D IF FRAMING IS SPACED AT 16' ON CENTER, OR PANELS ARE APPLIED 111TH LONG DIMENSION ACROSS STUDS FOR FRAMING SPACED AT 24" (BLOCKED). WHERE PANELS ARE APPLIED ON 90714 FACES OF A WALL AND NAIL SPACING IS LESS THAN 6 INCHES ON CENTER ON EITHER SiDE, PANEL JOINTS SHALL BE OFFSET TO FALL ON DIFFERENT FRAMING MEMBERS OR FRAMING SHALL BE 3—INCH NOMINAL AND NAILS ON EACH SIDE SHALL BE STAGGERED. MULLIKIN RESIDENC MAY 2006 S EASONS SCALE: 1714 W 7TH AVE DRAWN BY JEP PORT ANGELES, WA ENGINEERING, INC (360) 452 -3023 CHECKED: 619 S. Chase St. Port An ekes, WA 98362 SHEET: 2,3,6 2,3, 2,3,5 6 3, 6 1 11 1 1 1 1 -/---ito7 5 (i NA-7 Is` 16 4-i MUL_L__ItzPv le !SEASONS ENGINEERING, INC 36o) 452 3023 619 5 Chase St Port Angeles, WA 98362 6 P2.2( r) 1- 1 ?59 a- DATE: SCALE: DRAWN BY• CHECKED: SHEET OF 13.Pz-41 BOISE BC CALC 9.2 Design Report US Build 141 Job Name. Address: City State, Zip: Customer Code reports. ESR -1336 4� oe Ai AH1Yi..,ag ,l BO 2 1/2' LL 480 Ibs DL 204 Ibs Load Summary Description 1 Standard Load Controls Summary Pos. Moment End Reaction Total Load Defl. Live Load Defl. Max Defl. Span Depth Bearing Supports BO Wall /Plate B1 Wall /Plate Page 1 of 1 Value 2986 ft -Ibs 668 Ibs L/571 (0.372 L/814 (0.261') 0.372' 179 Load Type Unf Area Single 11 -7/8" BCI® 60 -2.0 DF 1 span No cantilevers 0/12 slope 16' OCS I Repetitive 1 Glued nailed construction File Name: BC CALC Project Description: J01 Specifier' Designer' Company Misc: Allowable 47 9% 56.9% 42.0% 59 0% 37.2% n/a Dim. (L x W) Value 2 1/2' x 2 5/16' 684 Ibs 2 -1/2' x 2 -5/16' 684 Ibs Total Horizontal Product Length 18 -00 -00 Live 100% 40 psf Ref. Start End Left 00 00 00 18 00 00 Duration 100% 100% Allow Support n/a n/a 18 -00 -00 Load Case 1 1 1 1 1 Notes Design meets Code minimum (L/240) Total load deflection criteria. Design meets User specified (L/480) Live load deflection criteria. Design meets arbitrary (1') Maximum load deflection criteria. Composite El value based on 23/32' thick sheathing glued and nailed to joist. Allow Member Material n/a Unspecified n/a Unspecified Dead 90% 17 psf Span Location 1 Internal 1 Right 1 1 1 1 JoistJ01 Monday May 22, 2006 15:20 nn f' t B1 2 1/2' LL 480 Ibs DL 204 Ibs Snow Wind Roof Live 115% 133% 125% OCS 16' Disclosure Completeness and accuracy of input must be verified by anyone who would rely on output as evidence of suitability for particular application. Output here based on building code- accepted design properties and analysis methods. Installation of BOISE engineered wood products must be in accordance with current Installation Guide and applicable building codes. To obtain Installation Guide or ask questions, please call (800)232 -0788 before installation. BC CALC® BC FRAMER® AJST"', ALLJOIST® BC RIM BOARDT"', BCI® BOISE GLULAMT"' SIMPLE FRAMING SYSTEM® VERSA -LAM®, VERSA -RIM PLUS® VERSA -RIM VERSA- STRANDT"" VERSA -STUD® are trademarks of Boise Wood Products, L.L.C. 7 1 1 i 1/ .1 vertical Damn 7,NsAro:91 Area Map V7 I 1 This mapIdrawing is produced by the Ciy of it ngelleerfol d es e us and pus This map is no to t intended be uspaerdras a Pr. r ose ra 0 Kx191-m- 6 WA-L 0 Propoo40 R.eS�de ce. M ULLI KIN REStp t-iC E, J LI W S TN LoT F G vcd� 24 g, Po 21 Pr IA S Ph 2c.C-1_. 0 0 00 0 z +gtS 5r.4 11 10 SIT>= LN 0 1.t1 Li) J J Prescriptive Approach Simple Form For the Washington State Energy Code 2003 Edition Climate Zone 1 Site Information Building Department Use Only Lot: Address: r 1 i Lj cit o r YkrcA ke s State \,,k) Pr p U,--V 3 Contact: G c\ u- y�t� Phone 3/06 L 1 b, (0 g Phone 2 3 LCD Co3 3 S Ca U FAX. EXHIBIT A Permit Notes. Table 6 -1 PRESCRIPTIVE REQUIREMENTS FOR GROUP R OCCUPANCY CLIMATE ZONE 1 Unlimited Glazing Option Only Option Glazing Glazing U- Factor Door Wall Wall Wall Slab Area U- Vaulted Above Interior Extenor on of Floor Vertical Overhead Factor Ceiling Ceiling Grade Below Below Floor Grade Grade Grade Unlimited III Group R 3 0 40 0.58 0.20 R 38 R 30 R21 R 21 R 10 R 30 R 10 Occupancy Only This Project complies with the following: The Project is a single family residence or duplex. The Project is wood frame OR all of the insulation is intenor or extenor of the framing ,All building components meet the requirements hsted m Table 6 -1 Option III. The Project will meet all other provisions of the WSEC and VIAQ The Project will take advantage of the following exceptions to the prescriptive option El 602.6 Exception 1 One door, that is 24ft. Or less, that does not meet the standards allowed. Location of the door taking this exception 0 602.6 Exception 2. Doors with a U- Factor of 0 40 allowed without calculations, Option III only Location of the Door (s) taking exception Type of Heat Source: W C- 0 1 1 K ?r e. r cret CtA/01 CI r—x-144 WAIL, ItIA446C Pr o poc›.ecA ke..-0 eAetc,e, le")(4-14 rs) MULLJKIM RE511) 1 1. 10 11 1' 1 714 PoIZI Lo 2_4 E., kcc-L. 0 co 00 oL.Ht 0 0 1 3 sap PLAN o 6 9-