HomeMy WebLinkAbout1916 Village Cir - BuildingPREPARED 5/21/10 8 05 21 INSPECTION TICKET PAGE 5
CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 5/21/10
ADDRESS 1916 VILLAGE CIR
TENANT NBR HABITAT FOR HUMANITY
CONTRACTOR HABITAT FOR HUMANITY OF CL CO
OWNER HABITAT FOR HUMANITY CL COUNTY
PARCEL 06 30 13 5 7 0200 0000
APPL NUMBER 09 00000885 RES NEW SFR
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
February 11 2010 10 36 44 AM jlierly
BLI 02 2/17/10 JLL BLDG INSULATION TIME 01 00
3/10/10 AP February 17 2010 8 19 04 AM 1pangrle
HARRY 681 6780 OR 808 0049
'EXTERIOR WALL INSULATION'
AFTERNOON
March 10 2010 9 22 09 AM jlierly
BLDR 01 2/25/10 JLL BLDG DRYWALL IBWP
2/26/10 AP February 25 2010 8 33 26 AM 1pangrle
HARRY 808 0049
SHEARNAILING ON DRYWALL
February 26 2010 10 36 36 AM jlierly
PW99 01 5/11/10 RV PUBLIC WORKS FINAL
5/11/10 AP May 20 2010 10 40 21 AM rvess
May 20 2010 10 40 41 AM rvess
BL99 01 5/21/10 JLL/ BLDG FINAL
May 20 2010 10 28 57 AM 1pangrle
HARRY 808 0049
BUILDING FINAL
PERMIT ME 00 MECHANICAL PERMIT
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
ME1 01 10/26/09 JLL MECHANICAL ROUGH IN
10/26/09 DA October 23 2009 4 11 19 PM 1pangrle
HARRY 360 808 0049
'RADIANT HEAT TUBING FOAM UNDERSLAB
clean street and provide construction entrance recall
inspection jll
ME99 01 5/21/10 J L, MECHANICAL FINAL
May 20 2010 10 29 33 AM 1pangrle
MECHANICAL FINAL
HARRY 808 0049
PL 00 PLUMBING PERMIT
REQUESTED INSP DESCRIPTION
COMPLETED RESULT RESULTS /COMMENTS
SUBDIV
PHONE (360) 681 6780
PHONE (360) 681 6780
PERMIT
TYP /SQ
PL1 01 10/14/09 JLL PLUMBING UNDER SLAB
10/14/09 AP October 14 2009 8 49 51 AM 1pangrle
VINCENT 461 9635
UNDERSLAB PLUMBING
October 14 2009 4 16 14 PM jlierly
PL1 02 10/27/09 JLL PLUMBING UNDER SLAB
10/27/09 AP October 27 2009 8 18 09 AM 1pangrle
CONTINUED ONTO NEXT PAGE
PREPARED 5/21/10 8 05 21 INSPECTION TICKET PAGE 6
CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 5/21/10
ADDRESS 1916 VILLAGE CIR
TENANT NBR HABITAT FOR HUMANITY
CONTRACTOR HABITAT FOR HUMANITY OF CL CO
OWNER HABITAT FOR HUMANITY CL COUNTY
PARCEL 06 30 13 5 7 0200 0000
APPL NUMBER 09 00000885 RES NEW SFR
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
SUBDIV
PHONE (360) 681 6780
PHONE (360) 681 6780
HARRY 808 0049
UNDERSLAB FOAM RADIANT TUBING
October 27 2009 3 50 26 PM jlierly
PL6 01 1/28/10 JLL PLUMBING WATER SUPPLY
1/28/10 AP January 28 2010 9 07 47 AM pbarthol
HARRY 808 0049
January 28 2010 4 34 30 PM jlierly
PL2 01 2/08/10 JLL PLUMBING ROUGH IN
2/11/10 AP February 4 2010 12 01 07 PM 1pangrle
HARRY 808 0049
PLUMBING (ROUGH IN
February 11 2010 10 36 44 AM jlierly
PL99 01 5/21/10 J L PLUMBING FINAL
May 20 2010 10 29 59 AM 1pangrle
I HARRY 808 0049
PLUMBING FINAL
COMMENTS AND NOTES
PREPARED 2/25/10 8 35 41 INSPECTION TICKET PAGE 2
CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 2/25/10
ADDRESS 1916 VILLAGE CIR SUBDIV
TENANT NBR HABITAT FOR HUMANITY
CONTRACTOR HABITAT FOR HUMANITY OF CL CO PHONE (360) 681 6780
OWNER HABITAT FOR HUMANITY CL COUNTY PHONE (360) 681 6780
PARCEL 06 30 13 5 7 0200 0000
APPL NUMBER 09 00000885 RES NEW SFR
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
BLI 02 2/17/,10
BLDR 01 2/25/10
February 11 2010 10 36 44 AM jlierly
BLDG INSULATION TIME 01 00
February 17 2010 8 19 04 AM 1pangrle
HARRY 681 6780 OR 808 0049
'EXTERIOR WALL INSULATION'
AFTERNOON
BLDG DRYWALL IBWP
February 25 2010 8 33 26 AM 1pangrle
HARRY 808 0049
SHEARNAILING ON DRYWALL
COMMENTS AND NOTES
PREPARED 2/17/10 8 20 26 INSPECTION TICKET PAGE 3
CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 2/17/10
ADDRESS 1916 VILLAGE CIR
TENANT NBR HABITAT FOR HUMANITY
CONTRACTOR HABITAT FOR HUMANITY OF CL CO
OWNER HABITAT FOR HUMANITY CL COUNTY
PARCEL 06 30 13 5 7 0200 0000
APPL NUMBER 09 00000885 RES NEW SFR
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
BLI 02 2/17/10
SUBDIV
February 11 2010 10 36 44 AM jlierly
BLDG INSULATION TIME 01 00
February 17 2010 8 19 04 AM 1pangrle
HARRY 681 6780 OR 808 0049
EXTERIOR WALL INSULATION
AFTERNOON
COMMENTS AND NOTES
PHONE (360) 681 6780
PHONE (360) 681 6780
PREPARED 2/08/10 8 17 19 INSPECTION T CKET PAGE 2
CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 2/08/10
ADDRESS 1916 VILLAGE CIR SUBDIV
TENANT NBR HABITAT FOR HUMANITY
CONTRACTOR HABITAT FOR HUMANITY OF CL CO PHONE (360) 681 6780
OWNER HABITAT FOR HUMANITY CL COUNTY PHONE (360) 681 6780
PARCEL 06 30 13 5 7 0200 0000
APPL NUMBER 09 00000885 RES NEW SFR
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
PL1 01 10/14/09 JLL PLUMBING UNDER SLAB
10/14/09 AP October 14 2009 8 49 51 AM 1pangrle
VINCENT 461 9635
UNDERSLAB PLUMBING
October 14 2009 4 16 14 PM jlierly
PL1 02 10/27/09 JLL PLUMBING UNDER SLAB
10/27/09 AP October 27 2009 8 18 09 AM 1pangrle
HARRY 808 0049
UNDERSLAB FOAM RADIANT TUBING
October 27 2009 3 50 26 PM jlierly
PL6 01 1/28/10 JLL PLUMBING WATER SUPPLY
1/28/ 0 AP January 28 2010 9 07 47 AM pbarthol
HARRY 808 0049
January 28 2010 4 34 30 PM jlierly
PL2 01 2/08/ 0 February ROUGH IN
/J February 4 2010 12 01 07 PM 1pangrle
HARRY 808 0049
PLUMBING (ROUGH IN
COMMENTS AND NOTES
PREPARED 2/08/10 8 17 19 INSPECTION TICKET
CITY OF PORT ANGELES INSPECTOR JAMES LIERLY
ADDRESS 1916 VILLAGE CIR SUBDIV
TENANT NBA HABITAT FOR HUMANITY
CONTRACTOR HABITAT FOR HUMANITY OF CL CO PHONE (360) 68 6780
OWNER HABITAT FOR HUMANITY CL COUNTY PHONE (360) 681 6780
PARCEL 06 30 13 5 7 0200 0000
APPL NUMBER 09 00000885 RES NEW SFR
PERMIT BPR 00 BUILDING PERMIT RESIDENTIAL
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
BL1 01 9/22/09 JLL BLDG FOUNDATION FOOTING TIME 09 00
9/22/09 AP September 22 2009 8 35 34 AM 1pangrle
TOMMY 477 0778
FOOTING
MORNING
September 22 2009 4 15 24 PM jlierly
BL2 01 9/24/09 PB BLDG FOUNDATION STEM WALL TIME 09 00
9/25/09 AP September 24 2009 8 19 07 AM 1pangrle
DANNY 477 7315
STEMWALL
MORNING
September 25 2009 9 19 51 AM pbarthol
BLFD 01 10/01/09 JLL BLDG FOUNDATION DRAINAGE
10/01/09 AP September 30 2009 3 07 49 PM pbarthol
HARRY 808 0049
October 1 2009 4 23 13 PM jlierly
BLIS 01 10/01/09 JLL BLDG INSULATION /SLAB
10/01/09 AP September 30 2009 3 08 28 PM pbarthol
HARRY 808 0049
October 1 2009 4 23 13 PM jlierly
DSD 01 10/01/09 JLL BLDG DOWN SPOUT DRAINS
10 /0 /09 AP September 30 2009 3 07 12 PM pbarthol
HARRY 808 0049
October 1 2009 4 23 13 PM jlierly
BLI 01 12/01/09 JLL BLDG INSULATION TIME 01 00
12/01/09 AP November 30 2009 10 21 38 AM 1pangrle
HARRY 681 6780
INSULATION BEHIND THE TUB /SHOWER
AFTERNOON
December 1 2009 4 05 22 PM jlierly
BL9 01 12/01/09 JLL BLDG SHEARWALL TIME 01 00
12/01/09 AP November 30 2009 10 20 41 AM 1pangrle
HARRY 681 6780
EXTERIOR WALL OSB NAILING
AFTERNOON
December 1 2009 4 05 22 PM jlierly
BAIR 01 2/08/10 BLDG AIR SEAL
February 4 2010 12 00 07 PM 1pangrle
HARRY 808 0049
AIRSEAL
BL3 01 2/08/10 L BLDG FRAMING
February 4 2010 12 00 48 PM 1pangrle
HARRY 808 0049
FRAMING
PERMIT PL 00 PLUMBING PERMIT
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
CONTINUED ONTO NEXT PAGE
PAGE 1
DATE 2/08/10
PREPARED 1/28/10 11 09 41 INSPECTION TICKET PAGE 3
CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 1/28/10
ADDRESS 1916 VILLAGE CIR
TENANT NBR HABITAT FOR HUMANITY
CONTRACTOR HABITAT FOR HUMANITY OF CL CO
OWNER HABITAT FOR HUMANITY CL COUNTY
PARCEL 06 30 13 5 7 0200 0000
APPL NUMBER 09 00000885 RES NEW SFR
PERMIT PL 00 PLUMBING PERMIT
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
SUBDIV
PHONE (360) 681 6780
PHONE (360) 681 6780
PL1 01 10/14/09 JLL PLUMBING UNDER SLAB
10/14/09 AP October 14 2009 8 49 51 AM 1pangrle
VINCENT 461 9635
UNDERSLAB PLUMBING
October 14 2009 4 16 14 PM jlierly
PL1 02 10/27/09 JLL PLUMBING UNDER SLAB
10/27/09 AP October 27 2009 8 18 09 AM 1pangrle
HARRY 808 0049
UNDERSLAB FOAM RADIANT TUBING
October 27 2009 3 50 26 PM jlierly
PL6 01 1/28/10 J L PLUMBING WATER SUPPLY
January 28 2010 9 07 47 AM pbarthol
HARRY 808 0049
t COMMENTS AND NOTES
Application Number
Application pin number
Property Address
ASSESSOR PARCEL NUMBER
Application type description
Subdivision Name
Property Use
Property Zoning
Application valuation
Application desc
New home
Owner
HABITAT FOR HUMANITY CL COUNTY
PO BOX 1479
PORT ANGELES WA 98362
(360) 681 6780
Permit
Additional desc
Permit pin number 159186
Permit Fee 110 30
Issue Date 1/06/10
Expiration Date 7/11/10
Qty Unit Charge
1 00 110 3000
Fee summary
Permit Fee Total
Plan Check Total
Grand Total
INSPECTION TYPE
DITCH
SERVICE
ROUGH IN
FINAL
COMMENTS
10 00000015
412250
1916 VILLAGE CIR
06 30 13 5 7 0200 0000
ELECTRICAL ONLY
PLANNED RESDNTL DEVLPMENT
0
Contractor
ELECTRICAL NEW RESIDENTIAL
Per
ECH
Charged
ELECTRICAL PERMIT
CITY OF PORT ANGELES
360 417 -4735
KIRSCH ELECTRIC INC
P 0 BOX 3396
SEQUIM
(360) 683 6819
Plan Check Fee
Valuation
Date 1/13/10
WA 98382
Extension
110 30
Paid Credited Due
EL R SQFT FIRST 1300
110 30 110 30 00 00
00 00 00 00
110 30 110 30 00 00
DATE RESULTS
00
0
Signature of owner or Electrical Contractor X Date
INSPECTOR.
JAN -5 -2010 03 55P FROM KIRSCH ELECTRIC 3606830869 TO 4174711 P 1
J
City of Part Angeles Permit Application
Building Division/Electrical Inspections
321 East Filth Street P.O. Box 1150
Port Angeles Washington, 98362
Ph: (160) 417 -4715 Fax: (160) 417.4711
Date:
8 2 Single Fatuity Dwelling
Multi- Family or Commercial'
Commercial Addition Alteration Remodel Repair'
Plan Review May Be Requi d Please Cgigiplete tri�'Qla ev Info lion h
Job Address: l U� lam+ r,►'�
Building Square Footage:
Description of above
Unit Charge
93.75
$113.75
$160.00
$205.00
$291.25
2.00
57.50
2.00
S 72.50
86.25
$116.25
$131.25
75.00
69.00
75.00
50.00
50.00
93.75
80.00
86.25
27.50
57.50
86.25
43.75
Owner Information
Name: i4p, i-r
Mailing Address: geg 1tl `T 1
City 12.6 State: LOA Zip: 9f 3L?_
Phone:
License Exp.
RECEIVE
JAN 6 2009
ELECTRICAL
INSPECTIONS
Contractor Informs 'on
Name: fa i a
Mailing A. Kiii1111 f i
City .ii tat Zip: *WW2
Phone: iU r
License 01 Exp. Ward V.
1..
Total (fir Mulliglied brLU
SertlicelFeeder 200 Amp.
Service/Feeder 201-400 Amp.
Service/Feeder 401 -600 Amp.
Service/Feeder 601 -1000 Amp.
ServicelFeeder over 1000 Amp.
Branch Circuit W/ Service Feeder
Branch Circuit W/O Service Feeder
Each Additional Branch Circuit
Tarry. Service! Feeder 200 Amp.
Temp. Servlcelfeeder 201 -400 Amp.
Temp. Service/Feeder 401-600 Amp.
Temp. ServicelFeeder 601 -1000 Amp.
Portal to Portal Hourly
SignlOutline Lighting
Signal CircuiU Limited Energy Commercial
Signal Circuit/ United Energy 1 2 Family Dwelling
Signal Circuit/ limited Energy Multi-Family Dwelling
Manufactured Home Connection
i Renewable Electrical Energy 5KVA System or Less
$_Fast 1300 Square Ft
Each Additional 500 Square Ft or Portion of
Each Outbuilding or Detached Garage
Each Swimming Pool or Hot Tub
Thermostat
Total
1,
O w n e r as definer/by R C N 1 9 1 2 6 1 Wilmer will occupy the struc ureforruo years alter this electrical permit is finalized (1 )Owner isrequired to hire an
electrical contm r.f or if aba ye said property Is /or sale, rent or lease
After reading the above statement. I hereby certify that I am the owner of the above named property or a licensed electrical contractori am making the electrical
installation or alteration in compliance with the electrical laws, N.E.C., RCW. Chapter 1929, WAC. Chapter 296-168. The City of Port Angeles Municipal Code, and
Utility Specifications.
Signature of owner, electrical contractor or electrical administrator
Date: I, \itt--)
Application Number
Application pin number
Property Address
ASSESSOR PARCEL NUMBER
Tenant nbr name
Application type description
Subdivision Name
Property Use
Property Zoning
Application valuation
Application desc
INSTALL A FIRE SPRINKLER SYSTEM
Owner
HABITAT FOR HUMANITY CL COUNTY
PO BOX 1479
PORT ANGELES WA 98362
(360) 681 6780
Structure Information 000 000
Permit
Additional desc
Permit pin number
Permit Fee
Issue Date
Expiration Date
Fee summary
Permit Fee Total
Plan Check Total
Grand Total
CITY OF PORT ANGELES
FIRE DEPARTMENT PERMIT
321 East 5th Street, Port Angeles, WA 98362
09 00001373 Date 1/04/10
975025
1916 VILLAGE CIR
06 30 13 5 7 0200 0000
HABITAT FOR HUMANITY CL C
FIRE SPRINKLER SYSTEM
PLANNED RESDNTL DEVLPMENT
1800
Contractor
INNOVATED FIRE SPRINKLERS
81 NEW HAVEN LANE
PORT ANGELES
(360) 452 7583
INSTALL A FIRE SPRINKLER SYSTEM
FIRE SPRINKLER RESIDENTIAL
FIRE SPRINKLER SYSTEM
159004
00 Plan Check Fee
1/04/10 Valuation
7/03/10
Special Notes and Comments
A full acceptance test will be required for the fire
sprinkler system
Charged Paid Credited
00 00 00
00 00 00
00 00 00
WA 98362
Due
00
00
00
00
1800
This permit becomes null and void if work authorized is not commenced within 180 days, if work is suspended or
abandoned for a period of 180 days afer the work has commenced, or if required inspections have not been requested with
180 days from the last inspection. I hereby certify that I have read and examines this application and know the same to be
true and correct. All provisions of recognized standards, laws and ordinances governing this type of work will be compled
with whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel
the provisions of any state or local law regulating the work specified in the permit.
LAS 1 /s /ia
Signature of Contractor or AuPhorized Age z Date Signature of Owner (if Owner is builder) Date
FIRE PERMIT INSPECTION RECORD
Call 360 417 -4655 for fire inspections Please provide a minimum 24 -hour notice It is unlawful to cover, insulate
or conceal any work before inspected and accepted. Post permit in a conspicuous location.
KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE
Inspection Type I Date Passed I Comments
FIRE SPRINKLER
Underground piping hydrostatically tested
Underground piping flushed
Interior piping hydrostatically tested I
Interior piping inspection
Dry system air tested at 40 psi (24 hours)
Sprinkler final 5-1i-lo le-kb
I FIRE ALARM
Rough -in inspection
Alarm final
LP -GAS Completed by Contractor-
Underground piping inspection /pressure test Test #1
Above ground piping inspection/pressure test Piping pressure test psi
Time initiated
Tank (container) inspection Test #2
Appliance inspection Piping pressure test psi
Time initiated
LP -gas final
UNDERGROUND STORAGE TANK (UST) ABANDONMENT
Removal of flammable /combustible liquids
Tank appropriately abandoned
UST abandonment final
PERMIT OTHER (specify)
permit final
GENERAL COMMENTS
2/15/00
6
F
N
V)
LC
PV)
Heat System
o Other
BUILDING PERMIT
CITY OF PORT ANGELES
Attn Building Permit Technician
321 E. Fifth St. Port Angeles, WA 98362
(360) 417 -4815 fax (360) 417 -4711
Applicant or Agent v �C z 4 Z-pc. f'�
Owner F�� I Fc, H
Owner's Address 2-E) F N v ci L., I
Contractor /Engineer A /A /vVJ i l- J2
Contractor /Engineer's Address 6/ /VeL U
License )A/A/0 UF_(' U LP
PROJECT ADDRESS 1 Ick C `v c I
Parcel Number l q b Lot
Protect TWO Brief Description. Residential o Commercial
Check all that apply
New Construction
o Addition
Remodel
Repair
Re -roof
o Demolition
Sign
.i_ h.. Tts_ It
wall- mounted projecting freestanding a awning other
Total sign area so ft. Maximum allowed sign area so. ft.
o Heat pump wood burning stove a gas fireplace pellet stove a other
Floor Areas Existing (sq. ft.) Proposed g. ft.)
Basement per sq. ft.
161 Floor
2 Floor
3 Floor
Garage
Carport
Covered Porch
Deck
Shed
Other
Total footprint of structures 1 mac— (3 0 sq ft. Lot size
Max. height of proposed structures ft. Occupancy group
Will a lawn sprinkler system be installed? Occupant load
Will a fire sprinkler system be installed? Construction type
APPLICATION Print in ink
Expires
For City Use Only
Date Received 12- 2 0-65
Permit (3'1
Date Approved
Phone Li S 7Scam.3
Phone
Pr R,ox PA ,u3A- 13362-
Phone L S2- S 6
8// z fio
Zoning
Multi family a Industrial
TOTAL VALUATION btiQ, D
sq ft. Lot coverage
of bedrooms
of full baths
of half baths
I have read and completed this application and know it to be true and correct. I am authorized to apply for this permit and
understand that it is my responsibility to determine what permits are required, and to obtain permits prior to working on
Print Name v�
Dat e projects.
1 k g s A I3 f
Date ��1 30\ 0`� C e Q v^ Signature !t.
T:Forms /Building Division /Bldg Permit Appl. -2006 Code doc
PREPARED 12/01/09 8 04 05 INSPECTION TICKET PAGE 3
CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 12/01/09
ADDRESS 1916. VILLAGE CIR SUBDIV
TENANT NBR HABITAT FOR HUMANITY
CONTRACTOR HABITAT FOR HUMANITY OF CL CO PHONE (360) 681 6780
OWNER HABITAT OF HUMANITY OF PHONE (360) 681 6780
PARCEL 06 30 13 5 7 0200 0000
APPL NUMBER 09 00000885 RES NEW SFR
PERMIT BPR 00 BUILDING PERMIT RESIDENTIAL
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
BL1 01 9/22/09 JLL BLDG FOUNDATION FOOTING TIME 09 00
9/22/09 AP September 22 2009 8 35 34 AM 1pangrle
TOMMY 477 0778
FOOTING
MORNING
September 22 2009 4 15 24 PM jlierly
BL2 01 9/24/09 PB BLDG FOUNDATION STEM WALL TIME 09 00
9/25/09 AP September 24 2009 8 19 07 AM 1pangrle
DANNY 477 7315
STEMWALL
MORNING
September 25 2009 9 19 51 AM pbarthol
BLED 01 10/01/09 JLL BLDG FOUNDATION DRAINAGE
10 /01/09 AP September 30 2009 3 07 49 PM pbarthol
HARRY 808 0049
October 1 2009 4 23 13 PM jlierly
BLIS 01 10/01/09 JLL BLDG INSULATION /SLAB
10/01/09 AP September 30 2009 3 08 28 PM pbarthol
HARRY 808 0049
October 1 2009 4 23 13 PM jlierly
DSD 01 10/01/09 JLL BLDG DOWN SPOUT DRAINS
10/01/09 AP September 30 2009 3 07 12 PM pbarthol
HARRY 808 0049
October 1 2009 4 23 13 PM jlierly
BLDG INSULATION TIME 01 00
November 30 2009 10 21 38 AM 1pangrle
HARRY 681 6780
INSULATION BEHIND THE TUB /SHOWER
AFTERNOON
BL9 01 12/01/09 BLDG SHEARWALL TIME 01 00
BLI 01 12/01/09
L t
November 30 2009 10 20 41 AM 1pangrle
HARRY 681 6780
EXTERIOR WALL OSB NAILING
AFTERNOON
COMMENTS AND NOTES
PREPARED 10/27/09 8 23 29 INSPECTION TICKET PAGE 3
CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 10/27/09
ADDRESS 1916 VILLAGE CIR SUBDIV
TENANT NBR HABITAT FOR HUMANITY
CONTRACTOR HABITAT FOR HUMANITY OF CL CO PHONE (360) 681 6780
OWNER HABITAT OF HUMANITY OF PHONE (360) 681 6780
PARCEL 06 30 13 5 7 0200 0000
APPL NUMBER 09 00000885 RES NEW SFR
PERMIT PL 00 PLUMBING PERMIT
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
PL1 01 10/14/09 JLL PLUMBING UNDER SLAB
10/14/09 AP October 14 2009 8 49 51 AM 1pangrle
VINCENT 461 9635
UNDERSLAB PLUMBING
October 14 2009 4 16 14 PM jlierly
PL1 02 10/27/09 JLL PLUMBING UNDER SLAB
October 27 2009 8 18 09 AM 1pangrle
HARRY 808 0049
'UNDERSLAB FOAM RADIANT TUBING
COMMENTS AND NOTES
PREPARED 10/26/09 9 32 48 INSPECTION TICKET PAGE 8
CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 10/26/09
ADDRESS 1916 VILLAGE CIR
TENANT NBR HABITAT FOR HUMANITY
CONTRACTOR HABITAT FOR HUMANITY OF CL CO
OWNER HABITAT OF HUMANITY OF
PARCEL 06 30 13 5 7 0200 0000
APPL NUMBER 09 00000885 RES NEW SFR
PERMIT ME 00 MECHANICAL PERMIT
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
ME1 01 10/26/09 3.:!kir-
SUBDIV
COMMENTS AND NOTES
PHONE (360) 681 6780
PHONE (360) 681 6780
MECHANICAL ROUGH IN
October 23 2009 4 11 19 PM 1pangrle
HARRY 360 808 0049
RADIANT HEAT TUBING FOAM UNDERSLAB
ON CA tut-Q)6A
th.)
PREPARED 10/14/09 8 51 38 INSPECTION TICKET PAGE 2
CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 10/14/09
ADDRESS 1916 VILLAGE CIR
TENANT NBR HABITAT FOR HUMANITY
CONTRACTOR HABITAT FOR HUMANITY OF CL CO
OWNER HABITAT OF HUMANITY OF
PARCEL 06 30 13 5 7 0200 0000
APPL NUMBER 09 00000885 RES NEW SFR
PERMIT PL 00 PLUMBING PERMIT
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
PL1 01 10/14/09
j, PLUMBING UNDER SLAB
October 14 2009 8 49 51 AM 1pangrle
VINCENT 461 9635
UNDERSLAB PLUMBING
SUBDIV
COMMENTS AND NOTES
PHONE (360) 681 6780
PHONE (360) 681 6780
PREPARED 10/01/09 8 10 09 INSPECTION TICKET
CITY OF PORT ANGELES INSPECTOR JAMES LIERLY
ADDRESS 1916 VILLAGE CIR
TENANT NBR HABITAT FOR HUMANITY
CONTRACTOR HABITAT FOR HUMANITY OF CL CO
OWNER HABITAT OF HUMANITY OF
PARCEL 06 30 13 5 7 0200 0000
APPL NUMBER 09 00000885 RES NEW SFR
PERMIT BPR 00 BUILDING PERMIT RESIDENTIAL
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
BL1 01 9/22/09 JLL
9/22/09 AP
BL2 01 9/24/09 PB
9/25/09 AP
BLFD 01
BLIS 01
DSD 01
10/01/09
10/01/09
10/01/09
SUBDIV
PHONE
PHONE
BLDG FOUNDATION FOOTING
September 22 2009 8 35 34
TOMMY 477 0778
FOOTING
MORNING
September 22 2009 4 15 24
BLDG FOUNDATION STEM WALL
September 24 2009 8 19 07
DANNY 477 7315
STEMWALL
MORNING
September 25 2009 9 19 51
BLDG FOUNDATION DRAINAGE
September 30 2009 3 07 49
HARRY 808 0049
BLDG INSULATION /SLAB
September 30 2009 3 08 28
HARRY 808 0049
BLDG DOWN SPOUT DRAINS
September 30 2009 3 07 12
HARRY 808 0049
COMMENTS AND NOTES
(360) 681 6780
(360) 681 6780
TIME 09 00
AM 1pangrle
PM jlierly
TIME 09 00
AM 1pangrle
AM pbarthol
PM pbarthol
PM pbarthol
PM pbarthol
PAGE 5
DATE 10/01/09
PREPARED 9/24/09 8 20 20 INSPECTION TICKET PAGE 3
CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 9/24/09
ADDRESS 1916 VILLAGE CIR
TENANT NBR HABITAT FOR HUMANITY
CONTRACTOR HABITAT FOR HUMANITY OF CL CO
OWNER HABITAT OF HUMANITY OF
PARCEL 06 30 13 5 7 0200 0000
APPL NUMBER 09 00000885 RES NEW SFR
PERMIT BPR 00 BUILDING PERMIT RESIDENTIAL
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
SUBDIV
PHONE (360) 681 6780
PHONE (360) 681 6780
BL1 01 9/22/09 JLL BLDG FOUNDATION FOOTING TIME 09 00
9/22/09 AP September 22 2009 8 35 34 AM 1pangrle
TOMMY 477 0778
FOOTING
MORNING
September 22 2009 4 15 24 PM jlierly
BL2 01 9/ 4/09 JL BLDG FOUNDATION STEM WALL TIME 09 00
l
September 24 2009 8 19 07 AM 1pangrle
ci DANNY 477 7315
STEMWALL
MORNING
COMMENTS AND NOTES
rr
I
r
PREPARED 9/22/09 8 46 00 INSPECTION TICKET PAGE 8
CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 9/22/09
ADDRESS 1916 VILLAGE CIR
TENANT NBR HABITAT FOR HUMANITY
CONTRACTOR HABITAT FOR HUMANITY OF CL CO
OWNER HABITAT OF HUMANITY OF
PARCEL 06 30 13 5 7 0200 0000
APPL NUMBER 09 00000885 RES NEW SFR
PERMIT BPR 00 BUILDING PERMIT RESIDENTIAL
REQUESTED INSP DESCRIPTION
TYP /SQ COMPLETED RESULT RESULTS /COMMENTS
BL1 01 9/22/09
SUBDIV
COMMENTS AND NOTES
PHONE (360) 681 6780
PHONE (360) 681 6780
BLDG FOUNDATION FOOTING TIME 09 00
September 22 2009 8 35 34 AM 1pangrle
TOMMY 477 0778
FOOTING
MORNING
2` 0-r?- :-L-1.6k.
1�
Application Number
Application pin number
Property Address
ASSESSOR PARCEL NUMBER
Tenant nbr name
Application type description
Subdivision Name
Property Use
Property Zoning
Application valuation
Application desc
1 306 SF SFR 42 SF COVERED PORCH
Owner
HABITAT OF HUMANITY OF
CLALLAM COUNTY
PO BOX 1479
PORT ANGELES
(360) 681 6780
Structure Information
Other struct info
Permit PUBLIC WORKS RES WATER SERV
Additional desc 3/4 DROP IN METER
Permit pin number 153536
Permit Fee 355 00 Plan Check Fee 00
Issue Date 9/16/09 Valuation 111514
Expiration Date 3/15/10
Qty Unit Charge Per
1 00
Permit
Additional desc
Permit pin number
Permit Fee
Issue Date
Expiration Date
1 00
Permit
Additional desc
Permit pin number 153486
Separate Permits are required for electrical work, SEPA, Shoreline ESA, utilities private and public improvements This permit becomes
null and void if work or construction authorized is not commenced within 180 days if construction or work is suspended or abandoned
for a period of 180 days after the work as commenced or if required inspections have not been requested within 180 days from the last
inspection I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of
laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not
presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
construction.
T \Policies \1102,15 [10/08]
Qty Unit Charge
135 0000
355 0000 EA PW WATER METER DROP IN
WA 98362
Signature o'oKractor or Authorized Agent
CITY OF PORT ANGELES
PUBLIC WORKS UTILITIES
321 EAST 5TH STREET PORT ANGELES, WA 98362
09 00000885
842090
1916 VILLAGE CIR
06 30 13 5 7 0200 0000
HABITAT FOR HUMANITY
RES NEW SFR
PLANNED RESDNTL DEVLPMENT
111514
Contractor
HABITAT FOR HUMANITY
728 E FRONT ST
PORT ANGELES
(360) 681 6780
000 000 1 306 SF SFR 42 SF COVERED
TOTAL LOT COVERAGE
CONSTRUCTION TYPE
FIRE SPRINKLERS REQUIRED
NUMBER OF STORIES
LOT SIZE
PROPOSED LOT COVERAGE
TOTAL LOT COVERAGE
NUMBER OF UNITS
PUBLIC WORKS STORMWATER
153494
135 00 Plan Check Fee
9/16/09 Valuation
3/15/10
Per
EA SAN SEW STM CON OTHER
SANITARY SEWER HOOK UP
0
Date'
Date
VB
YES
9/16/09
OF CL CO
WA 98362
PORCH
20 10
1 00
6682 00
1348 00
1348 00
1 00
Extension
355 00
00
111514
Extension
135 00
Signature of Owner (if owner is builder) Date
CALL 417 -4831 FOR UTILITY INSPECTIONS PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLAWFUL TO COVER,
INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT IN A CONSPICUOUS LOCATION
KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE
INSPECTION TYPE DATE ACCEPTED COMMENTS
PW UTILITIES (Engineering Division)
WATERLINE METER
SEWER CONNECTION
SANITAR Y
STORM
SITE DRAINAGE
SITE EROSION CONTROL
PARKING
SIDEWALK
CURB GUTTER
DRIVEWAY APPROACH
BACK -FLOW DEVICE
RESIDENTIAL
CONSTRUCTION R.W PW/
ENGINEERING 417 -4831
FIRE
PLANNING DEPT
BUILDING
T \Policies \1102.15 [10/08]
417 -4653
417 -4750
417 -4815
PERMIT INSPECTION RECORD
YES
NO
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE
DATE YES NO COMMERCIAL DATE ACCEPTED
YES NO
CONSTRUCTION R.W
PW ENGINEERING
FIRE DEPT
PLANNING DEPT
BUILDING
Application Number
Application pin number
Permit Fee
Issue Date
Expiration Date
Qty Unit Charge Per
1 00 135 0000 EA SAN SEWER HOOKUP
Special Notes and Comments
Address numbers shall be plainly visible from the street
Address numbers shall be a minimum of six inches high and be
of contrasting color from the background
All homes in new subdivisions that are outside of the Fire
Department four minute response area shall be equipped with
residential fire sprinkler systems that comply with the
International Fire Code (IFC) and National Fire Protection
Association (NFPA)
September 1 2009 3 18 41 PM sroberds
The proposal will result in a single sfr in the RHD /PRD for
lot coverage of 20% and site coverage of 25% No land use
issues anticipated
September 3 2009 4 50 18 PM Bob Larson 360 417 4706
City Electrical Department will need to do additional
underground work at no cost to the customer to make
underground power available at this lot
Electrical load calculations and electrical permits are
required
All connections to storm drain facilities require an
inspection by Public Works and Utilities Engineering prior
cover Notice will be given 48 hours in advance of
commencing work
Sanitary sewer connection inspection is required by
Public Works prior to back fill of ditch 24 hour advance
notice is required
September 1 2009 8 29 01 AM rbecker
If the fire sprinkler system is a closed system you will
need to install a double check backflow assembly If it is
an open system you will not need to install a backflow
assembly
Other Fees
Fee summary
T \Policies \1102 15 [10/08]
CITY OF PORT ANGELES
PUBLIC WORKS UTILITIES
321 EAST 5TH STREET PORT ANGELES, WA 98362
09 00000885
842090
135 00 Plan Check Fee
9/16/09 Valuation
3/15/10
Page 2
Date 9/16/09
RES UNDERGRND SERVICE FEE 713 00
SEWER SYSTEM DELV CHARGE 1510 00
STATE SURCHARGE 4 50
PW WATER SYSTEM USE FEE 1510 00
Charged Paid Credited Due
Permit Fee Total 625 00 625 00 00 00
Plan Check Total 00 00 00 00
Other Fee Total 3737 50 3737 50 00 00
Grand Total 4362 50 4362 50 00 00
0 0
111514
Extension
135 00
Separate Permits are required for electrical work, SEPA, Shoreline ESA, utilities private and public improvements This permit becomes
null and void if work or construction authorized is not commenced within 180 days if construction or work is suspended or abandoned
for a period of 180 days after the work as commenced or if required inspections have not been requested within 180 days from the last
inspection I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of
laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not
presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of
construction.
Signature of Contractor or Authorized Agent Date Signature of Owner (if owner is builder) Date
CALL 417 -4831 FOR UTILITY INSPECTIONS. PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLAWFUL TO COVER,
INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT IN A CONSPICUOUS LOCATION
INSPECTION TYPE DATE ACCEPTED
PW UTILITIES (Engineering Division)
WATERLINE METER
SEWER CONNECTION
SANITARY
STORM
SITE DRAINAGE
SITE EROSION CONTROL
PARKING
SIDEWALK
CURB GUTTER
DRIVEWAY APPROACH
BACK -FLOW DEVICE
T ,Policies \1102 1 [10/08]
RESIDENTIAL
CONSTRUCTION R.W PW/
ENGINEERING 417 -4831
FIRE 417 -4653 I
PLANNING DEPT 417 -4750 I
BUILDING 417 -4815 I
PERMIT INSPECTION RECORD
KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE
YES I NO
COMMENTS
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE
DATE YES NO COMMERCIAL DATE ACCEPTED
YES I NO
CONSTRUCTION R.W
PW ENGINEERING
I FIRE DEPT
I PLANNING DEPT
I BUILDING
rt
Application Number
Application pin number
Property Address
ASSESSOR PARCEL NUMBER
Tenant nbr name
Application type description
Subdivision Name
Property Use
Property Zoning
Application valuation
Application desc
1 306 SF SFR 42 SF COVERED PORCH
Owner
Permit
Additional desc
Permit pin number
Permit Fee
Issue Date
Expiration Date
CITY OF PORT ANGELES
DEPARTMENT OF COMMUNITY ECONOMIC DEVELOPMENT BUILDING DIVISION
321 EAST 5TH STREET PORT ANGELES WA 98362
1oR
HABITAT X HUMANITY PY
CLALLAM COUNTY r
PO BOX 1479
PORT ANGELES
(360) 681 6780
Structure Information
Other struct info
Qty Unit Charge Per
12 00 5 6000
7 2500 EA
10 6500 EA
14 8000 EA
5 00
1 00
1 00
T:Forms/Building Division/Building Permit
WA 98362
THOU
Qty Unit Charge Per
09 00000885
842090
1916 VILLAGE CIR
06 30 13 5 7 0200 0000
HABITAT FOR HUMANITY
RES NEW SFR
PLANNED RESDNTL DEVLPMENT
111514
000 000 1 306 SF SFR 42 SF COVERED PORCH
TOTAL LOT COVERAGE
CONSTRUCTION TYPE VB
FIRE SPRINKLERS REQUIRED YES
NUMBER OF STORIES
LOT SIZE
PROPOSED LOT COVERAGE
TOTAL LOT COVERAGE
NUMBER OF UNITS
BUILDING PERMIT RESIDENTIAL
1 306 SF SFR 42 SF COV PRCH
152603
1087 45
9/16/09 Valuation
3/15/10
BASE FEE
BL -100 001 500K (5 60 PER K)
Permit MECHANICAL PERMIT
Additional desc
Permit pin number 152728
Permit Fee 111 70 Plan Check Fee 00
Issue Date 9/16/09 Valuation 0
Expiration Date 3/15/10
BASE FEE
ME VENT FAN (SINGLE DUCT)
ME STOVE /FIREPLACE /MISC APP
ME HEATER(SUSP /WALL /FLOOR MTD)
Separate Permits are required for electrical work, SEPA, Shoreline, ESA, utilities, private and public improvements. This permit becomes null and
void if work or construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned for a period of 180 days
after the work has commenced, or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have
read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will
be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any
state or local law regulating construction or the performance of construction.
Contractor
Plan Check Fee
Date
9/16/09
HABITAT FOR HUMANITY OF CL CO
728 E FRONT ST
PORT ANGELES WA 98362
(360) 681 6780
20 10
1 00
6682 00
1348 00
1348 00
1 00
9 IL-o4' 1-Ira an_ 1 G2✓l v►:irct -rX 'U re"
Date Print Name Signature of Contractor or Authorized Agent
706 84
111514
Extension
1020 25
67 20
Extension
50 00
36 25
10 65
14 80
Signature of Owner (if owner is builder)
Inspection Type
FOUNDATION
Footings
Stemwall
Foundation Drainage Downspouts
Piers
Post Holes' (Pole Bldgs.)
PLUMBING
Under Floor Slab
Rough -In
Water Line (Meter to Bldg)
Gas Line
Back Flow,/ Water
AIR SEAL.
Walls
Ceiling
FRAMING
Joists Girders Under Floor
Shear Wall Hold Downs
Walls Roof Ceiling
Drywall (Interior Braced Panel Only)
T -Bar
INSULATION.
Slab
Wall Floor Ceiling
MECHANICAL.
Heat Pump Furnace FAU Ducts
Rough -In
Gas Line
Wood Stove Pellet Chimney
Commercial Hood Ducts
MANUFACTURED HOMES
Footing Slab
Blocking Hold Downs
Skirting
BUILDING PERMIT INSPECTION RECORD
PLEASE PROVIDE A MINIMUM 24 -HOUR NOTICE FOR INSPECTIONS
Building Inspections 417 4815 Electrical Inspections 417 4735
Public Works Utilities 417 4831 Backflow Prevention Inspections 417 4886
IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED
POST PERMIT IN CONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE.
Date
PLANNING DEPT Separate Permit #s SEPA.
Parking Lighting I I ESA.
Landscaping I I SHORELINE.
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/ USE
Inspection Type
Electrical 417 -4735
Construction R.W PW Engineering 417 -4831
Fire 417 -4653
Planning 417 -4750
Building 417 -4815
T.Forms /Building Division /Building Permit
Accepted By Comments
FINAL Date
FINAL Date
Accepted by
Accepted by
Date Accepted By
CITY OF PORT ANGELES
DEPARTMENT OF COMMUNITY ECONOMIC DEVELOPMENT BUILDING DIVISION
321 EAST 5TH STREET PORT ANGELES WA 98362
Application Number
Application pin number
Other Fees
T:Forms/Building Division/Building Permit
09 00000885
842090
Page 2
Date 9/16/09
Permit PLUMBING PERMIT
Additional desc
Permit pin number 152736
Permit Fee 156 00 Plan Check Fee 00
Issue Date 9/16/09 Valuation 0
Expiration Date 3/15/10
Qty Unit Charge Per Extension
BASE FEE 50 00
10 00 7 0000 EA PL PLUMBING TRAP 70 00
1 00 7 0000 EA PL WATER LINE 7 00
1 00 15 0000 EA PL -SEWER LINE 15 00
2 00 7 0000 EA PL -WATER HEATER 14 00
Special Notes and Comments
Address numbers shall be plainly visible from the street
Address numbers shall be a minimum of six inches high and be
of contrasting color from the background
All homes in new subdivisions that are outside of the Fire
Department four minute response area shall be equipped with
residential fire sprinkler systems that comply with the
International Fire Code (IFC) and National Fire Protection
Association (NFPA)
September 1 2009 3 18 41 PM sroberds
The proposal will result in a single sfr in the RHD /PRD for
lot coverage of 20% and site coverage of 25% No land use
issues anticipated
September 3 2009 4 50 18 PM Bob Larson 360 417 4706
City Electrical Department will need to do additional
underground work at no cost to the customer to make
underground power available at this lot
Electrical load calculations and electrical permits are
required
All connections to storm drain facilities require an
inspection by Public Works and Utilities Engineering prior
cover Notice will be given 48 hours in advance of
commencing work
Sanitary sewer connection inspection is required by
Public Works prior to back fill of ditch 24 hour advance
notice is required
September 1 2009 8 29 01 AM rbecker
If the fire sprinkler system is a closed system you will
need to install a double check backflow assembly If it is
an open system you will not need to install a backflow
assembly
RES UNDERGRND SERVICE FEE
SEWER SYSTEM DELV CHARGE
STATE SURCHARGE
PW WATER SYSTEM USE FEE
Fee summary Charged Paid Credited Due
713 00
1510 00
4 50
1510 00
Separate Permits are required for electrical work, SEPA, Shoreline, ESA, utilities, private and public improvements. This permit becomes null and
void if work or construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned for a period of 180 days
after the work has commenced, or if required inspections have not been requested within 180 days from the last inspection I hereby certify that I have
read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will
be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any
state or local law regulating construction or the performance of construction.
Date Print Name Signature of Contractor or Authorized Agent Signature of Owner (if owner is builder)
IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED
POST PERMIT IN CONSPICUOUS LOCATION KEEP PERMIT AND APPROVED PLANS AT JOB SITE.
BUILDING PERMIT INSPECTION RECORD
Inspection Type Date Accepted By Comments
FOUNDATION
Footings
Stemwall
Foundation Drainage Downspouts
Piers
Post Holes (Pole Bldgs.)
PLUMBING
Under Floor Slab
Rough -In
Water Line (Meter to Bldg)
Gas Line
Back Flow Water
AIR SEAL.
Walls
Ceiling
FRAMING
Joists Girders Under Floor
Shear Wall Hold Downs
Walls Roof Ceiling
Drywall (Interior Braced Panel Only)
T -Bar
INSULATION
Slab
Wall Floor Ceiling
MECHANICAL.
Heat Pump Furnace FAU Ducts
Rough -In
Gas Line
Wood Stove Pellet Chimney
Commercial Hood Ducts
MANUFACTURED HOMES
Footing Slab
Blocking Hold Downs
Skirting
PLEASE PROVIDE A MINIMUM 24 -HOUR NOTICE FOR INSPECTIONS
Building Inspections 417 4815 Electrical Inspections 417 4735
Public Works Utilities 417 4831 Backflow Prevention Inspections 417 4886
PLANNING DEPT Separate Permit #s SEPA.
Parking Lighting I ESA.
Landscaping I SHORELINE.
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/ USE
Inspection Type
Electrical 417 -4735
Construction R.W PW Engineering 417 -4831
Fire 417 -4653
Planning 417 -4750
Building 417 -4815
T:Forms /Building Division /Building Permit
FINAL Date Accepted by
FINAL Date Accepted by
Date Accepted By
Application Number
Application pin number
Permit Fee Total
Plan Check Total
Other Fee Total
Grand Total
CITY OF PORT ANGELES
DEPARTMENT OF COMMUNITY ECONOMIC DEVELOPMENT BUILDING DIVISION
321 EAST 5TH STREET PORT ANGELES WA 98362
Page 3
09 00000885 Date 9/16/09
842090
1355 15 1355 15 00 00
706 84 706 84 00 00
3737 50 3737 50 00 00
5799 49 5799 49 00 00
Separate Permits are required for electrical work, SEPA, Shoreline, ESA, utilities, private and public improvements. This permit becomes null and
void if work or construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned for a period of 180 days
after the work has commenced, or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have
read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will
be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any
state or local law regulating construction or the performance of construction.
Date Print Name Signature of Contractor or Authorized Agent Signature of Owner (if owner is builder)
T:FormsBuilding DivisionBuilding Permit
FOUNDATION
Footings
Stemwall
MANUFACTURED HOMES
Footing Slab
Blocking Hold Downs
Skirting
T Forms /Building Division /Building Permit
BUILDING PERMIT INSPECTION RECORD c3
—0
PLEASE PROVIDE A MINIMUM 24 -HOUR NOTICE FOR INSPECTIONS
Building Inspections 417 4815 Electrical Inspections 417 4735 CD
Public Works Utilities 417 4831 Backflow Prevention Inspections 417 4886 OD
IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED
POST PERMIT IN CONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE.
Inspection Type Date Accepted By Comments
0 Fe- N.Wiatlee9
1 —act
(99 I Tt.L
Foundation Drainage Downspouts)
Piers I
Post Holes (Pole Bldgs.)
PLUMBING
Under Floor Slab in -I 4 -129_ l
Rough -In z- a 10 I 7LL—
Water Line (Meter to Bldg)
Gas Line I
Back Flow Water I FINAL Date 5 -2 Accepted by
AIR SEAL.
Walls
Ceiling
FRAMING
Joists Girders Under Floor
(Shear Wally Hold Downs
Walls Roof Ceiling
D (Interior Braced Panel Only?
T -Bar
INSULATION
Slab
Wall Floor Ceiling
MECHANICAL.
Heat Pump Furnace FAU Ducts
Rough -In
Gas Line
Wood Stove Pellet Chimney d
Commercial Hood Ducts FINAL Date 5 --I Accepted by SLt_—
Electrical 417 -4735
Construction R.W PW Engineering 417 -4831
Fire 417 -4653
Planning 417 -4750
Building 417 -4815
(O=2-7-o4 uhdl.a -s1 aJ F
0 Eeeaktnq
2-s- to -scLA_-
a -g -10
I I
I Z (9 f T �I I=_X.Ee4o°r, tw ass ►ail: ni
I I
2q
1Z- I UQ. JLI i hS u (a'I7Sri belokut Tub /S t, o uses`
I -r) I E2 :nsu %o2flonAlill1oTLa
PLANNING DEPT Separate Permit #s SEPA.
Parking Lighting I ESA.
Landscaping I SHORELINE.
FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/ USE
Inspection Type
Date Accepted By
RESIDENTIAL PLAN REVIEW GUIDELINES
City of Port Angeles
Building Division
321 E 5 St
Port Angeles, WA 98362
PLAN REVIEW
Items described here are only a guide to common questibrns and missed items during plan review and
construction All codes must be complied with (Please read and follow each item) SPECIAL NOTE. Check
item #59 first to see if engineering will be needed because of lateral design issues.
GENERAL.
1 Final grading of the property must be done prior to final inspection even if owner is doing required retaining
walls Occupancy of the home will not be allowed until there are no slopes steeper than 2 units horizontal
to 1 unit vertical or retaining walls are in place or an accepted soils report is submitted to the City If a
soils report was required initially all requirements of the soils report rriust be accomplished prior to final
inspection including submittal of all field reports
2. Acrylic stucco products have special requirements Verify such with the manufacturer Requirements may
include tongue and groove foam board under finish control joints special backing boards (sometimes OSB
is NOT allowed) self- furring or furred -out wire or fabric lath and sometimes installation by a certified
installer (certified by the manufacturer) Verify any and all requirements of stucco siding or acrylic stucco
products. NO INSPECTION OF LATH OR STUCCO IS REQUIRED, BUT WRITTEN CERTIFICATION
fir. BY A MANUFACTURER'S CERTIFIED INSTALLER MUST BE LEFT AT THE JOB SITE UNTIL FINAL
INSPECTION BY THE CITY
3. Inspection of shear wall nailing roof sheathing to blocking nailing and hold downs must be requested in
addition to standard inspections and before such items are covered up Please specify shear nail roof nail
or hold -down inspection when you request these they may be done simultaneously if ready
4 This plan is approved for OSB or plywood exterior wall sheathing only unless the approved plans at .the
time of permit issuance reflect other materials being used Any change to wall sheathing material after
permit issuance must be submitted to the city for review prior to installation An additional plan review fee
will be assessed
5 "Tyvek' or equal approved weather resistive barrier (15# felt is. OK) required on the exterior side of all
walls regardless of the type of siding used This includes garage walls gable portion of end walls and
cripple walls (at stepped foundation conditions) Apply over exterior sheathing or over studs in single -wall
construction T 1 11 or similar panel siding must have "Tyvek' or equal over the studs.
6 Exterior windows and doors shall be flashed with approved materials and caulking Caulked trim material
over the window or door flange is not an acceptable method
7 Overall dimensions of house plan must match site plan dimensions Verify any special requirements for
buildings located close to property lines R302
T Buildi'1g /Handouts /Residential Plan Revie\� Guidelin I
18 09)
Page 1 of 8
LIFE SAFETY MISC ITEMS
8. Sleeping rooms must have an egress window with 5 7 s f net clear opening 24" min height, 20' min
width 44 maximum from floor to window sill Windows must meet all 4 dimensions R310 '1
9 Safety or tempered glass shall be used in windows that are (R308 4)
Adjace h t to a door (24 arc of either edge of the door in a closed position)
That are closer than 18' to floor (AND individual pane is more than 9 s f top edge more than 36" a.f f
and walking surface within 36' horizontally of the window in question)
Walls enclosing a tub or shower (AND within 60" of the drain or within 60' of walking surface) R308 4
Adjace t to stairways landings and ramps within 36' horizontally of a walking surface (AND less than
60" a f f. of the walking surface)
Adjacent to stairways within 60" of the bottom tread of the stair in any direction (AND less than 60'
aff)
10 Under -stair areas that are enclosed and accessible must be sheetrocked 1/2' GWB on walls and
underside of the stairway R311 2 2
11 Stairways shall have 10' min tread and 7 3/4 max rise R311 5
12. Provide 361' high guards (with 4" max. spacing on rails) at porches; balconies and raised floor surfaces
more than 30" above adjacent ground or floor R312 1
13 Smoke detectors required at all bedrooms hallway or room adjacent to bedrooms and at any ceilings that
are more than 24 above adjacent ceiling All smoke detectors interconnected and hardwired with battery
back -up' R313 1
14 Garage /house separation wall is 1/2" GWB door must be 20 min rated or 1 3/8" solid -core If living space
above use 5/8" GWB Type "X" at the ceiling AND 1/2" GWB at walls that support the floor above Ducts in
garage must be 26 -gage sheet steel and have no openings in the garage R309
15 Exterior stairways must have a light located near the top landing of the stairway switched from inside (or
have motion activation device) R303 6
16 Minimum room areas must be provided (120 s f min in at least one room 70 s f min all other habitable
rooms 7 foot min dimension in all habitable rooms) R304 1
17 Minimum ceiling heights must be provided (7 foot min with some exceptions) R305 1
FOOTINGS, FOUNDATIONS, AND CRAWL SPACES
18 All footings including exterior isolated pad footings must have a 24" (min) depth from the bottom of the
footing to fi fished grade R403 1 4 1
19 All footings shall be supported on undisturbed natural soils or engineered fill Any placement of fill material
that will support a structure will require a geotechnical investigation and report submitted to the City prior to
placement of footings R401 2 R403 1
20 Lots shall be graded to drain surface water away from foundations The grade shall fall 6" in the first TEN
feet around the perimeter of the structure R401 3
21 Top surface of footings shall be level Bottom surface of footings shall not have a slope that exceeds (1)
unit vertica in (10) units horizontal Any necessary stepping of the foundation must be approved during
plan review or prior to installation of the foundation R403 1 5
T Building /Handouts /Residential Plan Review Guidelines (Rev 03- 18 -09)
Page 2 of 8
0
22. Wood sill plates of all exterior walls interior bearing walls (slab -on- grade) and interior shear walls (slab -on-
grade) must be anchored to foundation or slab with 1 /2 X 10' J -bolts with a 2' X 2' X 3/16" plate washer
Anchor bolts to be placed a maximum of 12' and no closer than 3'/2" from the ends of the sill plate Each
piece of sill plate must have a minimum of (2) anchor bolts Anchor bolts shall be spaced no further than 6
feet apart. (Special spacing and sizing conditions may apply at alternate braced wall panels) R403 1 6
23 6" clearance required from finish grade to foundation mudsill plate R319
24 3 1/2' (min thickness for all concrete slabs -on -grade .R506 1
25 Footing and foundation wall SIZES for two pour system
(Foundation walls NOT over 5- feet:in height)
Footing supporting single story- 12' wide X 6" thick.
Foundation wall supporting, single story- 6' thick
Footing supporting two stories- 15" wide X 7" thick.
Foundation wall supporting two. stories- 8" thick.
Foundations that support more than two stories require an engineered design
26 Footing andfnd. REINFORCEMENT for two pour system (fnd walls NOT over 5 feet in. height)
(Footings supporting single or two stories)
One continuous #4 horizontal rebar placed at center of footing with 3' -(min) clearance from dirt.
(Foundation walls not over 5 feet in height)
One continuous #4 horizontal rebar placed within the top 12" of the wall
#4 vertical rebar placed at 48 inches o c max (wet set ok) with a 6 -inch "90- degree" "hook. A
minimum of (2) vertical bars to be placed at front garage wall returns
27 Monolithically poured foundation systems
Bottom of footing shall be 12' wide (min and extend to 24" below finished grade minimum
Footing shall have either one #5 continuous horizontal rebar placed at center and 8" above bottom of
footing or (2) #4 continuous horizontal rebar placed at center and in the middle third of the footing
measuring vertically
3 1/2' minimum slab thickness
When a monolithic system is used to support heated. spaces an R 10 insulation board must be
installed on the outside of the foundation extending from bottom of footing to top of slab Exposed foam
insulation above grade must be protected, from damage and sun with approved materials The material
used must extend a minimum of 12" below grade
28 Basement Walls (up to 9 feet) or Stem Walls (over 5 feet) or STEPPED FOUNDATIONS There are
special restrictions for this type of foundation wall under the new code In plan view the length of this type
of wall cannot exceed 35 feet. For stepped foundations this wall cannot exceed 7 feet high otherwise the
floor joists must connect DIRECTLY to the wall (for bracing the foundation wall) WET- SETTING IS NOT
allowed for the alternating hooks into the footing There are special blocking requirements if any of these
conditions cannot be met (note on the plans!) See R404 1
29 Under -floor pier pads supporting uniform load of wood framed floors shall be 18 "x 18" x 8" (min) Point
loads from other than floor girders will require larger footings sized according to the concentrated load
R403 1 1
30 Beams and /or girders in crawl space must meet span requirements for the loads imposed (from floor joists
and from any point loads) R501 2
T Building /Handouts /Residential P Ian Review Guidelines (Rev 03- 18 -09)
Page 3 of 8
47 Sawn lumber floor joists shall have 11/2 (min) bearing and shall lap 3 min at intermediate girders
Engineered I-joists shall have 1 3/4 (min) bearing (or per manufacturer's specifications)
48. Floor joists that are parallel to bearing partitions shall be doubled Some heavier load cases will require
girder beams or pony walls Bearing partitions perpendicular to floor joists shall not be offset from the
supporting girder more than the depth of the joists unless the floor joists are of sufficient size to carry the
load R502 4
49 Floor cantilever spans shall not exceed the depth of the nominal floor joists Floor cantilevers constructed
in accordance with Table R502 3 3 (1) shall be permitted when supporting a light framed bearing wall and
roof only R502 3 3
50 Block in between floor joists beneath all interior braced walls. (for walls perpendicular to joists) or align floor
joist with interior braced wall (see item #63 -T)
WALL FRAMING
51 Wall studs taller than 10 feet shall have a stud height analysis by a professional engineer or architect.
Table R602.3 5
•52: Non -load bearing stud heights shall be in accordance with Table R602.3 (5)
53. Studs shall be a minimum #3 grade standard grade or stud grade lumber R602 2
54 Where joists trusses or rafters are spaced more than 16" o c and the bearing studs below are spaced at
24 o c such members shall bear within 5" of the studs below unless the top plates are double 2x6 or a
third plate is added R602 3 3
55. Headers over windows and doors must meet minimum requirements for spans and imposed loads verify
point loads over openings (from trusses or other conditions) and size headers accordingly Headers must
be noted with size type and grade of lumber being used
GENERAL NOTE STATING ALL HEADERS SHALL BE is acceptable
56 Interior bearing walls must have headers over openings and must be supported to a foundation
57 Top plate splices shall be offset a minimum of 24 inches R602 3 2
58. Fire blocking required at dropped ceilings soffits coved- ceiling areas and every ten feet horizontally and
vertically at framed walls R602 8
59 Port Angeles is in Seismic Zone D1 Wind zone of 100 MPH Category C (within 1500 ft from shore line is
Category D) per the 2006 IRC When a house is considered IRREGULAR by any ONE the definitions
below the code will NOT allow prescriptive bracing for Seismic Zone C and the entire house must have a
lateral analysis and design by a licensed engineer (R301 2 2 2 2) Per that section of the code. NO MIXING
OF PRESCRIPTIVE AND ENGINEERED LATERAL SYSTEMS IS ALLOWED UNDER THIS NEW 2006
IRC.
The following are items that constitute an IRREGULAR BUILDING per the 2006 IRC
A. Exterior braced wall lines must be in one plane vertically from foundation to the uppermost story
(basically the upper floor must match the lower floor footprint) The most common area where
problems like this occur is in a garage with a second floor over it. To qualify for prescriptive bracing
the second floor joists must extend to the exterior walls of the garage If this does NOT occur then
your proposed house is IRREGULAR If the joists do extend to the exterior walls of the garage then
the setback of the second floor walls cannot be more than four (4) feet setback from the garage walls
T Building /Handouts /Resi,lential Plan Review Guidelines (Rev 03- 18 -09)
Page 5of8
(see p. 44 of the 2006 IRC) Rooms created by roof trusses are OK under this provision (such as
bonus rooms over garages formed by the trusses /rafters)
B The pe imeter of all floor diaphragms and all roof diaphragms must be supported on WALLS below If
you ha %e beams holding up any part of the perimeter of a floor or a roof then your proposed house is
IRREGULAR The most common place you will find this problem is at large covered porches and
patios where the roof is supported only by post and beams Such covered porches and patios also
make the building IRREGULAR Related to this are areas of discontinuous diaphragms especially
changes in plate line heights which also are considered as separate 'roofs and therefore make the
building IRREGULAR.
C In any elevation of the exterior the braced walls from an upper level wall must NOT occur over .a
window or door In general this means that 'the windows of the upper story .must align with the
windows of the lower story There are some exceptions based on up-sizing the header in the window
below (ee 2006 IRC p 44 for details)
D When an opening in a floor or roof (such as a balcony- overlook area or a courtyard area). exceeds the
lesser of 12 feet or 50% of the least dimension then your proposed house is IRREGULAR
E. When portions of a floor level are vertically offset (such as a sunken room) then your proposed house
is IRREGULAR This 'does not apply to a slab- on- gradefloor
F When braced wall lines do not occur in 'two perpendicular directions (such as 'portions of the house or
garage at an angle to the rest of the building) then your proposed house is IRREGULAR.
G If you have any portion of the above -grade walls that use masonry or concrete construction then your
proposed house is IRREGULAR Stepped foundations that create a daylight basement situation are
OK under this provision and do not make an irregular structure
60 THIS APPLIES TO ALL LATERAL BRACING (ITEMS 61 THRU 65). Add up all lengths of braced panels
(4 foot brac panels 2 -8' alt. braced panels and 24 or 16' portal frames COUNT as 48' of length each
portal frame counts as a total of 48' of bracing length —not 2 times 48 along .the wall in question The
total length of braced walls must be at least 16% of the entire wall length AND the panels must occur at
least every 25 feet along the wall For 1 story of 2 -story house 30% of the entire wall length must be
braced walls Check this for all braced wall lines including INTERIOR WALLS and including the front wall
of a garage if it is not part of another braced wall line .(i e the garage sticks out in front of the house more
than 4 feet)- See also #65 T below for areas where MORE than 35 feet between wall lines is needed
61 Garage lateral bracing systems with no 2 floor above
H Portal Frame for Garages (16" side panels 8 foot max. high walls 20" side panels 10'foot max.
high walls)
I Alternate Braced Walls— single -story condition (2' -8' min width X 10 foot max. height) sheathed on
one side (interior or exterior OK) with Min 3/8" OSB or plywood and nailed with 8d common or galv
box nails and blocked at all edges Two (2) anchor bolts in sill plate two (2) hold -down devices
furthest S tuds (1800 pound capacity hold- downs)
J Alternate Braced Walls —first floor of two -story condition (2' -8" min width X 10 foot max. height)
sheathed on BOTH interior and exterior sides of wall' with min 3/8" OSB or plywood and nailed with 8d
common or ,galv box' nails and blocked at all edges Two (2) anchor bolts in sill plate. two (2) hold
down devices furthest studs (3000 pound capacity .hold-downs) There are some provisions for plate
lines up to 12 feet high see Table R602 10 6 (basically a wider wall 3 -6' .min length for 12 feet high)
K. Front Garage Panels —no hold -downs required
L. The exterior braced wall lines in a detached or attached garage cannot be more than 35 feet apart in
either direction or interior braced walls must be provided
62. 1 Floor Conditions Four (4) foot solid walls at all corners and at every 25 feet along any braced wall
line OR use one of the methods below
M Portal Fame for a House (slab -on -grade floors ONLY) 16" min width for one -story structures 24 min
width foi first floor of 2 -story
T Building /Handouts /Residential Pian Review Guidelines (Rev 0J 18 -09)
Page 6 of 8
1
N Alternate Braced Walls— single -story condition (2' -8" min width X 10 foot max. height) sheathed on
one side (interior or exterior OK) with min 3/8' OSB or plywood and nailed with 8d common or galv
box nails and blocked at all edges Two (2) anchor bolts in sill plate two (2) hold -down devices
furthest studs (1800 pound capacity hold- downs)
O Alternate Braced Walls —first floor of two -story condition (2' -8" min width X 10 foot max. height)
sheathed on BOTH interior and exterior sides of wall with min 3/8" OSB or plywood and nailed with 8d.
common or galv box nails and blocked at all edges Two (2) anchor bolts in sill plate two (2) hold
down devices furthest studs (3000 pound capacity hold- downs) There are some provisions for plate
lines up to 12 feet high, see Table R602 10 6 (basically a wider wall 3 -6' min length for 12 feet high)
P Simpson" Brand StrongWalls —this method is still available following all the manufacturer's.
specifications for connections
Q. Entire House Sheathed with OSB or Plywood —this method allows smaller side panels than 4 feet in
accordance with Table R602 10 5 CHECK THE OPENING HEIGHTS ADJACENT TO THESE
PANELS!
63 1 Floor Conditions Braced wall (any of the methods listed above) must start at no more than 1:2'5 feet
away from the corner of the braced wall lines and then at every 25 feet (min) along the wall line
64 2 Floor Conditions Braced walls (either of the methods listed below) must be within 12 5 feet of the
corner of the wall line in question
R. Standard four (4) foot panels on 2 levels can start at no more than 12 5 feet away from the corner
S Entire House Sheathed with OSB or Plywood —this method allows smaller side panels than 4 feet in
accordance with Table R602 10 5 CHECK THE OPENING HEIGHTS ADJACENT TO THESE
PANELS!
65. Exterior braced wall lines (or together with some interior wall lines) cannot be more than 35 feet apart.
T Certain areas can be up to 50 feet apart between wall lines IF there is additional bracing along the
exterior wall in question (50/35 1 43 more bracing than normally required or in other words 23% of
the total wall in bracing for 1 -story wall 43% of the total wall in bracing for 1 story of a 2 -story house)
R602 10 1 1 Exception 1 and 2
U Interior Braced Walls can be used when exterior) walls are more than 25 feet apart. Interior Braced
Walls are minimum 1/2" GWB both sides of wall for a minimum length of 48 use 5d nails or screws at
7" o c Sole plate of wall must be attached to thickened slab footing (see item #22 above) with 1/2"
anchor bolt 6' -0" o c or solid blocking (walls perpendicular to joists) or LINE UP JOIST with braced
wall (walls parallel to joists)
66 The roof sheathing MUST nail into SOLID blocking and the block must connect to the double top plate
either with clips or toe nailed (for blocks that are top beveled) with 8d 6' o c For ventilation use not
more than two (2) 2' diameter holes BLOCKING MUST OCCUR AROUND ENTIRE PERIMETER OF
ALL ROOFS Table R602 3 (1) This applies to all houses both engineered AND prescriptive bracing
ROOF ATTIC
67 Truss drawings must show reactions of all girder trusses point loads onto headers must have headers
sized accordingly point loads over 5000 lbs onto double -top plates must be checked for bearing capacity
Use Simpson brand TBE4 or TBE6 as needed to spread the load
68 Truss bottom chord live load must be minimum of 10PSF (see Table R301 5) Trusses must .be sized for
the roof coverings specified on the plans (concrete tile etc) and roof structure must be able to hold up the
roof (beams headers etc sized for roof loads) R802 10 2
69 Ice Shield is required for roofs up to 6 12 (6 12 and over DO NOT require ice shield) R905 2 7 1
T Building /Handouts /Residential Plan Re yew Guide' ,es (Rev 03- 18 -09)
Page 7 of 8
70 Attic ventilation must be provided at 1 /150 of the attic area or 1 /300 of the attic area if 50% of the venting
can be 3 feet above the eave venting (roof jack vents are 49 sq in. /vent ridge vents at 12 sq in. /foot)
R806 1
71 Attic mechanical equipment need light and switch near opening and electric outlet. Access opening to
such mechanical equipment must be no further than 20 feet from equipment with 22" wide (min) walkway
from access opening to the equipment.
72. Attic access required X 30" min and shall be in hallway or other readily accessible location. R807 1
MECHANICAL.
73. Appliances located in a garage or carport shall be protected from damage' from vehicles M1307 3 1
74 Gas appliances located in a garage shall be raised 18' min above finish. floor G2408 2 (305 3)
75 Ductwork that extends below grade (such as in the garage floor) shall be encased in 2" min concrete on all
sides and bottom in addition .to the R -10 insulation foam board 603 8 IMC
76. Dryer exhaust ducts shall not exceed 25 feet in length The maximum length of the duct shall be reduced
2 5 feet for each 45- degree bend and 5 feet for each 90- degree bend Longer lengths in accordance with
the manufacturer's listing will be allowed Screws shall not be, used to connect any dryer duct materials
M1501 3
77 Flex duct connections to sheet metal transition ducts shall have the inner sleeve taped with approved
materials p to securing the flex duct with a zip tie or similar fastener 304 IMC
78 Flex duct shall be supported every 4 feet and have no sag that exceeds 'h per foot.
79 All exhaust fan ducts shall be connected to the fan housing and termination fittings with a minimum of 3
sheet metal screws and be sealed with approved tape or mastic.
80 Exhaust fans required 50 cfm in bathrooms 100 cfm in kitchen 50 cfm min in laundry room and one fan
sized for whole -house ventilation 302 2 2 WSVIAQ
81 Fuel- burning equipment shall not be installed in a closet, bathroom or a room readily usable as a bedroom
82. Water heaters must be secured to structure with straps around tank at 1/3 points to resist lateral
displacement. M1307 2
PLUMBING
83 Cleanouts shall be installed on all sinks and at the upper end of all building drains including any horizontal
drain branches greater than 5 feet in length from the main line A cleanout shall also be installed on the
exterior of the house within 24 inches of the foundation Wall level with final grade and shall have a
threaded type cap installed
84 30' min width for toilet and 24" clear space in front of toilet (UPC)
85. Water heaters pressure relief and the required drain pan shall have a drain that is 1/4 ID copper or cpvc
material NO coil material shall be allowed per code and no reduction in the pipe shall reduce the ID of the
material less than 3 Pex type is a coil material and is not allowed for this application
7 Build ng /Handouts /Residential Plan Review Guidelines (Rev 03- 18 -09)
Page 8of8
Applicant
Property
Property
Contractor
Contractor's
License
PROJECT ADDRESS
Parcel Number
Project Type Brief Description.
Check all that apply
mew Construction
Addition
Remodel
Repair
Demolition
Re -roof
Heat System
Other
Floor Areas
Basement
1 Floor
2 Floor
3 Floor
Garage
Carport
Covered Porch
Deck
Shed
Other
BUILDING PERMIT APPLICATION Print in ink
CITY OF PORT ANGELES
Attn Building Permit Technician
321 E. Fifth St. Port Angeles WA 98362
(360) 417 -4815 fax (360) 417 -4711
Owner
Owner's Address ,r-/7v L
>s
7.711 icrt .44 4-.4.,/ o--1
Address -5
NABr7,t1-192f.ca
0630 135/ 0200
ra*Iouse garage other tear off re -roof lay over one layer
Heat pump wood burning stove gas fireplace pellet stove mother Q4_J,
Existing (sq. ft.) Posed (sq. ft.)
C //4t� 4J
Expires G /2�,,
V
L.-Residential Multi family Commercial
5
G.. P2.0 5��.�, I 4 2C s
G ra ?Ac, t-
V
C.nit p n,w
C' (2 c c
Phone
Phone
Phone
a E -mail
jZ_
Lot 2d
For City Use Only
Date Received Oq
ermit# 35
1, ate Approved
36.6 -6 .4/ -4 c,
s r 4 3[, 2
ci
.I,4 i,,- -/d ...s ore?
RNA/
Zoning ?(Z
Industrial
(Jo r c
per sq ft. .CsIC�
TOTAL VALUATION A I t 5 19
Total footprint of structures /a qg sq ft. T Lot size _6GB 2 sq ft. Lot coverage Z Cs ..1%
Site Coverage the amount of impervious surface on a parcel including structures paved driveways sidewalks patios
and other impervious surfaces (see PAMC 17 94 135 for exemptions) Site coverage -2 `I, 8
\3x20 ParA∎n Pct. 7 1 vOSfside,wAlK 3105c 13 1 G53 662;7--
Max. height of proposed structures Es ft. Occupancy group of bedrooms S
Will a lawn sprinkler system be installed? ,IJ Occupant load of full baths 2
Will a fire sprinkler system be installed? y Construction type of half baths
I have read and completed this application and know it to be true and correct. I am authorized to apply for this permit and understand
that it is my responsibility to determine what permits are required, and to obtain permits prior to working onprojects.
D atecs-2. 4, Print Name ��-harzn Z".
4,. ,h, r Signature ;<1s
T Forms /Building Division /Bldg Permit.doc �j(L— c 4,)i2�'z7 -s1
1
j
A
so09
1912,
L i n dberg Rd
VIII
SIDE SETBACK
14 1"
Lot Area 6632
Structure Footprint 1305
5F
Living Area 1203 5F
Lot Coverage 20%
Roof Footbrint 150b 5F
M1
—A
60.91'
NT 350
5IDE SETBACK
6
1
SPECIAL BUILDING REQUIREMENTS
HOUSE TO BE ENERGY STAR CERTIFIED
1^1HOLE HOUSE SPRINKLERS
DRYINELL CAPACITY 196 CF
BUILDING CONTINUOUSLY SHEATHED
5HEAR PANELS FOR NORTH AND SOUTH WALLS
PRESCRIPTIVE PER 2006 IRG TABLE b 10.5
EAST INALL ENGINEERED TO ACCOMODATE PORCH FRONT DOOR
AND FUTURE REMOVAL OF EAST UTILITY WALL TO ATTACH GARAGE
SEE SCHEDULE 51 AND ATTACHED ENGINEERING CALCULATIONS
TEMPERED GLASS REQUIRED IN BATHROOM WINDOW
ATTIC VENTILLATION THROUGH CONTINUOUS RIDGE VENT AND VENTED SOFFIT
ALL EXHAUSTS VENTED TO EXTERIOR OF BUILDING
HEAT RECOVERY VENTILLATION REQUIRED 110 CFM INTAKE MIN 10' SEPARATION
FROM ALL EXHAUSTS
BATHROOM FANS 50 CFM VENTED THROUGH ROOF
RANGE HOOD VENT FAN 15 1 10CFM
r
0
CITY GOVERNMENT
Site Information. Building Department Use Only
Lot: ...?C) su4 U, f/S-4
.Address sib U, f/4 4 p n ,1,
City' '7 ti AG S
J
State L.() A Zip 9 S 6 z
Contact. /4,
Phone 3 G f, a e —C3o de 9
Phone2 a 6 c) -6 f
FAX ;3 Go es( 2&0
Table 6 -1
PRESCRIPTIVE REQUIREMENTS FOR GROUP R OCCUPANCY
CLIMATE ZONE 1
(Unlimited Glazing Option Only)
y
>C laiinnrla FaOttir nn,ir.�v 'W II
Vtorior':: Exterior
:Option,; r
t Ar:ewP /Olo fin �oo
r :p 3t Ceiling, Below: rBelow° r n
oor� Vertical r Ov&het Q.Factor
,w .i's'. Grade:,
Unlimited
Group R 3
IV and R -4 0 35 0 58 0.20 R 38 R -30 R 21 R 21 R 10 R 30 R 10
Occupancies
Only
This Project complies with the following:
11 The project is a single family residence or duplex.
11 The project is a wood frame OR all of the insulation is interior or exterior of the framing.
1I All building components meet the requirements listed above
The project will meet all other provisions of the WSEC and VIAQ
The Project will take advantage of the following exceptions to the prescriptive option.
602.6 Exception 2. One unlabeled or untested exterior swinging door, 24 sq.ft. or less, may be
installed per unit for ornamental, security, or architectural purposes
Location of the door taking this exception
602.6 Exception 2. If a door is mostly glass, it should meet the requirement of the vertical
glazing U- factor listed above
Location of the door(s) taking exception
Type of Heat Source n/
T:FormsiBuilding Division /Prescriptive Approach Simple Form
PRESCRIPTIVE APPROACH- SIMPLE FORM
For the Washington State Energy Code (2006 Edition)
Climate Zone 1
Permit
Notes
`Slab ora:
w
Please complete and return to Public Works Utilities Department
Applicant Information
Permanent service.
Name and address of party
responsible for permanent
service billing?
Contact Information
Site contact:
Contractor
Electrician
Excavator
Project Type
Ingle- family residence
Commercial
Overhead service
underground service
Project Information
Street address lot number
I Nearest cross street:
Desired connection date
Electrical Load
Voltage
Check all that apply
No Load Change
Name: //4
Street: 2 F a F es A 77
City State ZIP J,uCJ s
Da time Phone
(if other than above)
Name cla2n C'`i'4,L,/icnr Title Lrxc c4 t
Daytime Phone L a f_ c' 9Ao
I Name /./ann, �n��t/7 Company' ///Td
I Daytime Phone 1 7G� �a� cc�Y
Name .77:7 ,r Company
Daytime Phone
Name
Daytime Phone
Existing
Description of work:
/44 Re-4 eC G
D
.0 /A, T,A n
I 1JEC c3
Electrical transformer serving property is on a pole on the ground
A/C ton)
ajtlothes Dryer
El Heater
Supporting Documentation
G42
Electrical Information Form
Public Works Utilities Department (360) 417 -4700
City Electrical Inspector (360) 417 -4735
Home Phone :e,c).— 6 6/ _e p C
12
ci. ,4(.`..4 Z4 Company ,4" 'I
Multi-family residence of units
❑Subdivision of lots
❑General service
Other
Total square footage /3o G sq ft. Main disconnect size 2 oo amps
P120/240 1ph 0120/208 3ph 0277/480 3ph
0120/240 3ph 0480 3W 3ph Other
Standard residential loads (Lighting refrigerator dishwasher washer)
EI i ange /Oven Hot Tub
P=leating g:I Pumps eAlp)
Elevator Hp) Other
Please provide a copy of the following
*Detailed plot plan (dwg, or dxf format mandatory for subdivisions)
*Electrical one -line drawing showing the service entrance panel and location
*Connected load data.
*Size and locked rotor amps of all motors over 5 hp
Applicant's Signature Date
MAIL OR DELIVER COMPLETED FORM TO 321 E 5TH STREET PORT ANGELES WA 98362
FAX TO 360- 417 -4711
Information fo, n xls
WS
WF
N ,PWVS\i..IG. ;ENGI= -•1tt ri als,infor on for 1 15
924
El
6
19P I C-271
0
100A c/o
F 4UK
0 2P
ft0
7 •2 ::-J 3F SECT CAB
I 6 W/3-LBC4
J-35
2\
6, 23
1009
1013
1912
z re'T' l \e
i 19
4"PVC (Future
350 TPX
PS
1-4 3"e_v_c
i 16
U
g
rl
1/0 ALCN
17
J-2
Clallam County Assessor Treasurer Property Details 66752 HABITAT FOR HUMA Page 1 of 3
Clallam County Assessor Treasurer
Property Search Results 66752 HABITAT FOR HUMANITY CL COUNTY for Year 2009 2010
Property
Account
Property ID
Geographic ID
Type
Tax Area.
Open Space:
Historic Property'
Multi- Family Redevelopment: N
Location
Address
Neighborhood:
Neighborhood CD•
Owner
Name
Mailing Address.
Taxes and Assessments Due
66752
1916 VILLAGE CIR
PORT ANGELES WA 98362
Cycle 5 Res
10955130
Property Tax Information as of 12/10/2009
Amount Due if Paid on.
Year
2009
2009
2009
2009
2009
2009
2009
2009
2009
2009
Statement
ID
667522008
667522008
667522008
667522008
667522008
667522008
667522008
667522008
667522008
667522008
0630135702000000
Real
0010 PA 121 PORT ST CNTY H2 L
N
N
2009 667522008 TOTAL. $259.39
2008 667522007 ST SCH STATE SCHOOL $70 39
2008 667522007 CC -GEN COUNTY $34 06
2008 667522007 PORT PORT $4 98
2008 667522007 PORT ANG PORT ANGELES $73.35
2008 667522007 SD #121 SCHOOL DISTRICT #121 $82 10
2008 667522007 NTH OLY LIB NORTH OLYMPIC LIBRARY $9 90
2008 667522007 HOSP #2 HOSPITAL #2 $3 38
2008 667522007 FIRE_PATROL FIRE PATROL $8 95
Legal Description
Agent Code
Land Use Code
DFL
Remodel Property'
Mapsco.
Map ID
HABITAT FOR HUMANITY CL COUNTY Owner ID'
P 0 BOX 1479 Ownership
PORT ANGELES WA 98362
Exemptions:
First Second
Half Half
Base Base
Taxing Jurisdiction Due Due
ST SCH STATE SCHOOL $58 33 $58 32
CC -GEN COUNTY $29 53 $29 50
PORT PORT $4 18 $4 18
PORT ANG PORT ANGELES $64 76 $64 73
SD #121 SCHOOL DISTRICT #121 $72.13 $72.13
NTH OLY LIB NORTH OLYMPIC LIBRARY $8 58 $8 57
HOSP #2 HOSPITAL #2 $12.11 $12.10
FIRE_PATROL FIRE PATROL $8 70 $8 70
WEED CONTROL WEED CONTROL $0 82 $0 81
Admin Administrative Fee $0.25 $0.25
$259.29
$70 38
$34 05
$4 97
$73 33
$82.09
$9 89
$i 38
$8 95
Penalty
$0 00
$0 00
$0 00
$0 00
$0 00
$0 00
$0 00
$0 00
$0 00
$0 00
$0.00
$0 00
$0 00
$0 00
$0 00
$0 00
$0 00
$0 00
$0 00
PENINSULA VILLAGE
V15 P6 LOT 20 15A
28285
100 0000000000%
Interest
$0 00
$0 00
$0 00
$0 00
$0 00
$0 00
$0 00
$0 00
$0 00
$0 00
Base
Paid
$116 65
$59 03
$8 36
$129 49
$144.26
$17 15
$24.2.1
$17 40
$1 63
$0 50
$0.00 $518.68
$0 00 $140 77
$0 00 $68.11
$0 00 $9 95
$0 00 $146 68
$0 00 $164 19
$0'00 $1.9 79
$000 $676
$0 00 $17 90
Amount
Due
$0 00
$0 00
$0 00
$0 00
$0 00
$0 00
$0 00
$0 00
$0 00
$0 00
$0.00
$0 00
$0 00
$0 00
$0 00
$0 00
$0 00
$0 00
$0 00
ht p. /vp• ail un net 8084 /prop�rtyaccess, P )perty aspx =0&0, ear 2009& ~oh td =6 12/1 U'2009
if 6.110, Arthitect 8.Q -Full Version [Penninsula Vilbge2.PLi Plan],
1.(
,ons
5T A-3
T�ls Wui
goo6/").Egil...g. 0
L L- 1
it-kg 7 S1
:M.e 1.a.
CAMP fl L 1 i'
i CA13 ,Det
Aaii V
L E_J ,r,:. i
3068)
T rL-g:-,„3"3
HOU Li tF 0 nc-1 k 4,A13,
ss-r&I.L.f.tb
DJ L
11Y-0
A I nvjo 4
1-1 Pairis
Jj
vv.5 6
co
Co
"'Mg ViLuli
4
IX
uz_cpc eLAN))
fA-(-)°10g sr-Mow-0
rft-uss
FL..)Tuvr-S &gift A 6g
dikicti fyLoS ro
Tc-{, 040-A. A40\kg
toalt A55 ci-lec a'1°'c--'
AVM
D l
iii MN VA
ROI
agairgie
at 111111
OM": 01111
VORA' 41111
_.,ri. iir1t�11 a x($'1
sigiumm
rp
INWANN
r,��rrr
MUM
111•111111111111. 1rl�ri�i1
V
m ain
r
IN
rrrr 1 MI I 1 I VW ,f
MOM H 11 OM 44..
f i/i 1 11111 ■rr as rrr
rrrr _i►e ES
I N. iIII 1 r�w 91113rr 7 f I Li el I 111111
rrrrr UMW 11
NaNNI r_, NOM i!iia "ram I CI 1 I i
NM= 1 II�II
I V /Lii y V eT
I Li I I -I
1
itrei i! lr�i
rrYM�
ri!%!ai L�1
ass mar
1 111111 1 f
a 1
rr��,��r�..�
rrrrr rr rr_
"all" II r err I I
r r �r
rrrir>•
,111511 CM ill
rrrr.!�. J
r!1/riti� MR
rrrr• r 1 r
rr ®err Y
rr►arrrrrrr
1�!►i� I Irlr r�r 1 I rrr _I J i
I I I{ I I I I I I 11 I i l I I (I P If r7 1! i l I
II11111I4iillll
■NFAI NNINEN /1G7/rlrrrrrrri'
rrlli�i/J I I
-III1
I I I
1 1p
1
111 1
11 1
1 1
1111
11 1
i
11
W4A
11111
1 I lit
1' 1
I I
11
111
III
1 11
II
1
III
I I 1
II Ill 11
III II 1
111 II II
II
111
111
1 1
1
11
11
11
Il
1111
1
II
11
1
1 I
11
11
I 1
1 1
11
it
II
1 1
I I
I
Date
Company Name
Address
City
State
File Location
Basic Wind Speed(V)
Structural Category
Natural Frequency
Importance Factor
Alpha
At
Am
Cc
Epsilon
Slope of Roof
Ht Mean Roof Ht
RHt Ridge Ht
OH Roof Overhang at Eave=
2
Bldg Length Along Ridge
Leeward Walls -0 48
Side Walls -0 70
Elev Kz
ft
16 33
15 00
10 00
5 00
Note
MECAWind Version 2 0 2 2 per ASCE 7 -05
Developed by MECA Enterprises Inc Copyright 2009 www.mecaenterprises com
Wall
8/10/2009 Project No 09178
ZENOVIC ASSOCIATES Designed By SRH
301 EAST 6TH STREET SUITE1 Description SFR
PORT ANGELES Customer Name HABITAT FOR HUMANITY
WA Proj Location LOT 20 PENINSULA VILLAGE, PORT
\Zen server \data \Active Projects \09178 HABITAT \ENGR \Structual \WIND LOADING wnd
0 86
0 85
0 85
0 85
Roof Location
Kzt qz
psf
Windward Min Cp
Windward Max Cp
Leeward Perp to Ridge
Overhang Top (Windward)
Overhang Top (Leeward)
Overhang (Windward only)
1 00 18 81
1 00 18 47
1 00 18 47
1 00 18 47
User Input
100 00 mph
II
N/A
1 00
9 50
0 11
0 15
0 20
0 20
5 12
12 17 ft
16 33 ft
00 ft
9 46
9 24
9 24
9 24
Cp +GCpi(pef)
0 27
0 22
0 60
0 27
0 60
0 80
MWFRS -Wall Pressures Parallel to Ridge
10 83 -4 18
14 32 -7 67
Data
Structure Type
Exposure Category
Flexible Structure
Kd Directional Factor
Zg
Bt
Bm
1
Zmin
Slope of Roof(Theta)
Type of Roof
Eht Eave Height
Roof Area
Cp +GCpi(paf) GCpi(psf)
Figure 6 -6 External Pressure Coefficients
Cp Loads on Main Wind -Force Resisting Systems(Method 2)
MWFRS Wall Pressures Perpendicular to Ridge
36 00 ft Bldg Width Across Ridge= 40 00 ft
Main Wind Force Resisting System(MEOW)
Figure 6 -5 Internal Pressure for Buildings, GCpi
Enclosed Bldg +GCpi 0 18 Enclosed Bldg -GCpi -0 18
Windward Wall Total Shear Moment
+GCpi -GCpi -GCpi Kip K -ft
16 11
15 89
15 89
15 89
7 56
0 13
-12 75
24
9 42
12 56
20 29
20 06
20 06
20 06
1) Total Leeward GCPi Windward GCPi
2) Shear and Moment are sum of forces (Leeward +Windard)
GCpi(psf)
0 91
6 78
6 10
4 24
9 42
12 56
0 97 0 65
4 58 10 32
8 19 30 80
11 81 60 32
acting on bldg
Building
C
No
0 85
900 00 ft
1 00
0 65
500 00 ft
15 00 ft
22 61 Deg
Gabled
8 00 ft
780 00 ft^
Wall Cp +GCpi(psf) GCpi(psf)
Leeward Walls -0 50
Side Walls -0 70
16 33 0 86 1 00 18 81 9 46
15 00 0 85 1 00 18 47 9 24
10 00 0 85 1 00 18 47 9 24
5 00 0 85 1 00 18 47 9 24
Roof Dist from Windward Edge
0 0 ft to 6 1 ft
6 1 ft to 12 2 ft
12 2 ft to 24 3 ft
24 3 ft to 36 0 ft
-11 18 -4 53
-14 32 -7 67
Elev Kz Kzt qz Windward Wall Total Shear Moment
ft pef +GCpi -GCpi -GCpi Kip K -ft
16 11
15 89
15 89
15 89
0 90 -17 46
0 90 -17 46
-0 50 -11 18
0 30 -8 04
20 64
20 41
20 41
20 41
10 81
10 81
4 53
1 39
1 10
5 18
9 26
13 34
0 73
11 67
34 82
68 18
Note 1) Total Leeward GCPi Windward GCPi
2) Shear and Moment are sum of forces (Leeward +Windard) acting on bldg
Cp +GCpi(paf) GCpi(psf)
A U.S.DEPARTMENT OF HOUSING AND URBAN DEVELOPMENT I B TYPE OF LOAN
4• 1 FHA 2 ]FMHA 3 ]CONV UNINS
4 ]VA 5 ]CONV INS [X]Cash (6)
6 FILE NUMBER 7 LOAN NUMBER
Final 01093256
18 MTG INS CASE NO
C NOTE This form is furnished to give you a statement of actual settlement costs. Amounts paid to and by the settlement agent are shown. Items marked
"p.o.c.') were paid outside the closing: they are shown here for information purposes and are not included in the totals.
D NAME OF BORROWER HABITAT FOR HUMANITY
ADDRESS 728 E FRONT ST PORT ANGELES, WA 98362
E NAME OF SELLER OLYMPIC VIEW PARTNERS LLC
ADDRESS 2815 TOWNSGATE RD STE 330, WESTLAKE VILLAGE, CA 9 SELLER TIN
F NAME OF LENDER
ADDRESS
G PROPERTY LOCATION 06- 30 -13- 570200 LT 20 PENINSULA VILLAGE
LOT 20, PENINSULA VILLAGE
H SETTLEMENT AGENT OLYMPIC PENINSULA TITLE CO
ADDRESS
CLOSER KAREN WAHLSTEN PHONE NUMBER
SETTLEMENT AGENT TIN 91 1167753
PLACE OF SETTLEMENT OLYMPIC PENINSULA TITLE CO PHONE NUMBER I SETTLEMENT DATE
ADDRESS 319 -A S PEABODY Closing date 06/22/09
PORT ANGELES, WA 98362 Proration date 06/22/09
J SUMMARY OF BORROWER S TRANSACTION K SUMMARY OF SELLER S TRANSACTION
100 GROSS AMOUNT DUE FROM BORROWER. 1 400 GROSS AMOUNT DUE TO SELLER.
101 Contract sales price I 44,000 00 1 401 Contract sales price 44,000 00
102. Personal property 402. Personal property
103 Settlement charges to borrower(line 1400) I 214 09 1 403
104 I 1 404
105 11 405
Adjustments for items paid by seller in advance: Adjustments for items paid for seller in advance:
106 City /town taxes to
107 County taxes 06/22/09 to 07/01/09
108. Assessments to
109
110
111
112.
303 CASH f FROM/ f TOI BORROWER.
Seller
I 406 City /town taxes to
12 79 1 407 County taxes 06/22/09 to 07/01/09
I 408. Assessments to
I 409
410
411
I 412.
120. GROSS AMOUNT DUE FROM BORROWER. 420. GROSS AMOUNT DUE TO SELLER
44,226 88
200 AMOUNTS PAID BY OR IN BEHALF OF BORROWER. 500. REDUCTIONS IN AMOUNT DUE TO SELLER.
201 Deposit or earnest money 1,000 00 501 Excess deposit(see instructions)
202. Principal amount of new loan(s) I 502. Settlement charges to seller(line 1400)
203 Existing loan(s) taken subject to 1 503 Existing loan(s) taken subject to
204 ADD'L DEPOSIT TO ESCROW FUNDS TO CLOSE 43,226 88 1504 Payoff of first mortgage loan WESTSOUND BANK
205 1 505 Payoff of second mortgage loan
206 506.
207 507 PROPERTY TAXES 1ST 1/2 2009 PEN /INT
208. 508.
209 509
Adjustments for items unpaid by seller Adjustments for items unpaid by seller:
210. City/town taxes to 510. City/town taxes to
211 County taxes to 511 County taxes to
212. Assessments to 512. Assessments to
213 513
214 514
215 515
216 516.
217 517
218. 518.
219 519
220. TOTAL PAID BY /FOR BORROWER. 520. TOTAL REDUCTION IN AMOUNT
44,226 88
300. CASH AT SETTLEMENT FROM /TO BORROWER. 1 600 CASH AT SETTLEMENT TO /FROM SELLER.
301 Gross amount due from borrower(line 120) 44,226 88 1 601 Gross amount due to seller(line 420)
302. Less amounts paid by /for borrower(line 220) I 44,226 88 1 602. Less total reductions in amount due seller(line 520)
603 CASH f TO] f FROMI SELLER.
0 00
12 79
44,012 79
4,347 99
39,379 53
285 27
44,012 79
44,012 79
44,012 79
0 00
SUBSTITUTE FORM 1099 SELLER STATEMENT The information contained in Blocks E,G,H and I and on line 401 (or, if line 401 is asterisked, lines 403 and 404)
is important tax information and is being furnished to the Internal Revenue Service. If you are required to file a return, a negligence penalty or other sanction will
be imposed on you if this item is required to be reported and the IRS determines that it has not been reported.
SELLER INSTRUCTION -If this real estate was your principal residence, file Form 2119 Sale or Exchange of Principal Residence, for any gain, with your income tax
return; for other transactions, complete the applicable parts of Form 4797 Form 6252 and /or Schedule D (Form 1040).
You are required by law to provide Olympic Peninsula Title Company with your correct taxpayer identification number
If you do not provide Olympic Peninsula Title Company with your correct taxpayer identification number, you will be subject to civil or criminal penalties.
Under penalties of perjury I certify that the number shown on this statement is my correct taxpayer identification number.
4/S LDI
File .01091256 L. SETTLEMENT CHARGES
Final
700. TOTAL SALES /BROKER'S COMMISSION Based on 44, 000 00
Division of Commission (line 700) as follows:
701 $3,080 00
702. to
703 Commission paid at settlement
704
800. ITEMS PAYABLE IN CONNECTION WITH LOAN
801 Loan Origination fee
802. Loan Discount
803 Appraisal fee
804 Credit Report
805 Lender's inspection fee
806 Mortgage Insurance application fee
807 Assumption Fee
808.
809
810
811
812. to
900. ITEMS REQUIRED BY LENDER TO BE PAID IN ADVANCE.
901 Interest from to O$
902. Mortgage insurance premium for
903 Hazard insurance premium for
904
905
1000 RESERVES DEPOSITED WITH LENDER
1001 Hazard Insurance
1002. Mortgage insurance
1003 City property taxes
1004 County property taxes
1005 Annual assessments (Maint.)
1006
1007
1008.
1009 Aggregate Reserve for Hazard Flood Ins, City County Prop Taxes, Mortgage Ins. Annual Assessments
1100 TITLE CHARGES
1101 Settlement or closing fee to OLYMPIC PENINSULA TITLE CO
1102. Abstract or title search to
1103 Title examination to
1104 Title insurance binder to
1105 Document preparation to
1106 Notary fee to
1107 Attorney's fee to to
(includes above items No.
1108. Title insurance to OLYMPIC PENINSULA TITLE CO
(includes above items No.
1109 Lender's coverage
1110. Owner's coverage 44,000 00 175 00
1111 ESCROW FEE SLS TAX to OLYMPIC PENINSULA TITLE CO
1112. to
1113 OWNER'S PLCY SLS TAX to OLYMPIC PENINSULA TITLE CO
to
1114
1200. GOVERNMENT RECORDING AND TRANSFER CHARGES
1201 Recording fees: Deed 44 00 Mrtg Rel.
1202. City/county tax /stamps: Deed Mrtg
1203 State tax /stamps: Deed Mrtg
1204 EXCISE TAX CLALLAM COUNTY TREASURER
1205
1206 RECONVEYANCE /PROCESSING FEE
1300. ADDITIONAL SETTLEMENT CHARGES
1301 Survey
1302. Pest inspection
1303 FEDERAL EXPRESS HANDLING FEE
1304
1305
to
to
to
to
to
to
to
to
to
mo. to
yrs. to
yrs. to
to COLDWELL BANKER UPTOWN REALTY
mo.
mo.@$
mo.@$
mo.@$
mo.@$
mo.@$
mo.@$
mo.@$
to
to
to
WESTSOUND BANK
7 00
/day
per mo.
per mo
per mo.
per mo.
per mo.
per mo.
per mo.
per mo.
to
to
to OLYMPIC PENINSULA TITLE CO
to
to
1400 TOTAL SETTLEMENT CHARGES (entered on lines 103, Section J and 502, Section K)
CERTIFICATION I have carefully reviewed the HUD -1 Settlement Statement and to the best of my knowledge and belief, it is a true and accurate statement of all
receipts and disbursements made on my account or by me in this transaction. I further certify that I have received a copy of HUD -1 Settlement Statement.
Borrowers Sellers
The H D -1 Settlement Statement which I have prepared is a true and accurate account of this transaction.
accor nce with this stater 1/'/
I 1
Settlement Agent I 1 Date
PAGE
PAID FROM
BORROWER'S
FUNDS
3,080 00I AT SETTLEMENT
197 50
16 59
214 09
2 OF OMB No 2502 0265
PAID FROM
SELLER'S
FUNDS
AT SETTLEMENT
I have caused or will cause the funds to be disbursed in
WARNING• It is a rime to knowingly make false statements to the United States on this or any other similar form. Penalties upon conviction can include a fine and
imprisonment. For details see: Title 18: U.S Code Section 1001 and Section 1010.
3,080 00
197 50
175 00
16 59
14 70
44 00
788 20
7 00
25 00
4,347 99
Application Number
Application pin number
Property Address
ASSESSOR PARCEL NUMBER
Application type description
Subdivision Name
Property Use
Property Zoning
Application valuation
Application desc
Temp pole
Owner
Habitat for humanity clallam
P 0 Box 1479
PORT ANGELES
(360) 681 6780
Permit
Additional desc
Permit pin number
Permit Fee
Issue Date
Expiration Date
Fee summary
INSPECTION TYPE
DITCH
SERVICE
ROUGH IN
FINAL
COMMENTS
WA 98362
150680
72 50
7/29/09
1/25/10
ELECTRICAL PERMIT
CITY OF PORT ANGELES
360 417 -4735
09 00000738 Date 7/29/09
213410
1 11 3 U_.A4rc-- —4'
06 30 13 5 7 0310 0000
ELECTRICAL ONLY
RESIDENTIAL HIGH DENSITY
0
Contractor
OWNER
ELECTRICAL TEMPORARY SERVICE
DATE
Plan Check Fee
Valuation
Qty Unit Charge Per
1 00 72 5000 ECH EL -TEMP SRV 0 200 SRV FDR
Charged Paid Credited
Permit Fee Total 72 50 72 50 00
Plan Check Total 00 00 00
Grand Total 72 50 72 50 00
Due
00
00
00
RESULTS
8/7)/09 AV
S (oc7
00
0
Extension
72 50
Signature of owner or Electrical Contractor X Date
INSPECTOR.
JUL /21 /2009 /TUE 07 42 AM DEPT OF COMM DEV
Owner Information
Name' iIAIDTAT FoP..NUww tv (4.1A u.
Mailing Address: _Po 13ox M
City �'A State. wx Zip. 9R7 bZ-
Phone: GK I 6,71+1) Fax: 60 47 O
License Exp Lc)
Unit Charge
93.75
$113.75
$160.00
$205.00
$291.25
2.00
57.50
2.00
72.50
86.25
$116.25
$131.25
75.00
69.00
75.00
50.00
60.00
93.75
80.00
86.25
27.50
57.50
86.25
43.75
Signature of owner electrical contractor of electrical administrator
Date: P 3
L>CLC 'IVrrze..-
RECEIVED
JUL 28 2009
City of Port Angeles Permit Application
Building Division /Electrical Inspections
321 East FiRh Street- P.O. Box 1150
Port Angeles Washington, 98382
Ph: (360) 417-4735 Fax: (360) 4174711
Date: 7 Z Z- 09
S.1 2 Single Family Dwelling
Multi- Family or Commercial`'
Commercial Addition f Alteration I Remodel !Repair*
Plan Review May Required, Please Complete Electrical Plan Review Information Sheet
Job Address: FU LtLL-A4. l2
Building Square Footage: al 50
Description of above S itJC FAwn r.SY Dw t= LL.
ELECTRICAL
INSPECTIONS
Contractor Information
Name
Mailing Address:
City
Phone:
License Exp.
Cash
Check
Credit Card
State. Zip:
Fax:
Total (Qtv Multiplied by Unit Charge)
Service /Feeder 200 Amp.
Service /Feeder 201.400 Amp.
Service /Feeder 401 -600 Amp.
Service /Feeder 601 1000 Amp.
Service /Feeder over 1000 Amp.
Branch Circuit WI Service Feeder
Branch Circuit W/O Service Feeder
Each Additional Branch Circuit
S 'SU Temp. Service/ Feeder 200.Amp,
Temp. Service/Feeder 201400 Amp.
Temp. ServicelFeeder 401-600 Amp
5 Temp. Service/Feeder 601 1000 Amp.
Portal tor Portal Hourly
Sign /Outline Lighting
Signal Circuit/ Limited Energy Commercial
Signal Circuit/ Limited Energy 1 2 Family Dwelling
Signal Circuii/ Limited Energy Multi-Family Dwelling
Manufactured Home Connection
Renewable Electrical Energy 5KVA System or Less
First 1300 Square Ft.
Each Additional 500 Square Ft. or Portion of
Each Outbuilding or Detached Garage
Each Swimming Pool or Hot Tub'
Thermostat
72_5 Total
P 001 /004
Owner as defined by RCW 19.28,251 (1) Owner will occupy the structure for two years after this electrical permit Is finalized. (2) Owner is required to hire an
electrical contractor if above said property is for sale, rent or !ease.
After reading the above statement, 1 hereby certify that 1 am the owner of the above named property or a licensed electrical contractor I am making the electrical
Installation or alteration In compliance with the electrical laws, N.E.C. RCW. Chapter 19.28, WAC. Chapter 296.4613, The City-of Port Angeles Municipal Code, and
Utility Specifications.
c
c0
Application Number
Application pin number
Property Address
ASSESSOR PARCEL NUMBER
Application type description
Subdivision Name
Property Use
Property Zoning
Application valuation
Application desc
Temp pole
Owner
Hbitat for Humanity Clallam Co
P 0 Box 1479
PORT ANGELES WA 98362
Permit
Additional desc
Permit pin number
Permit Fee
Issue Date
Expiration Date
Fee summary
Permit Fee Total
Plan Check Total
Grand Total
INSPECTION TYPE
DITCH
SERVICE
ROUGH IN
FINAL
COMMENTS
09 00000669
542232
1916 VILLAGE CIR
06 30 13 5 7 0200 0000
ELECTRICAL ONLY
RESIDENTIAL HIGH DENSITY
0
Contractor
KIRSCH ELECTRIC INC
P 0 BOX 3396
SEQUIM
(360) 683 6819
ELECTRICAL TEMPORARY SERVICE
149674
72 50
7/07/09
1/03/10
Qty Unit Charge Per
1 00 72 5000 ECH EL TEMP SRV 0 200 SRV FDR
Charged
72 50
00
72 50
ELECTRICAL PERMIT
CITY OF PORT ANGELES
360- 417 -4735
Paid Credited
72 50
00
72 50
Plan Check Fee
Valuation
00
00
00
Date 7/07/09
WA 98382
DATE RESULTS
0 0
0
Extension
72 50
Due
00
00
00
GRA /-111-l_K_p 1 4 4P
Signature of owner or Electrical Contractor X Date
1
Div NIT 1
INSPECTOR.
City of Port Angeles Permit Application
Building Division /Electrical Inspections
321 East Fifth Street –P.O. Box 115D
Port Angeles Washington, 98362
Ph: (360) 417 -4735 Fax: (3 417 -4711
Dale: 7 i. 0'1
1 2 Single Family Dwelling
Multi Family or Commercial*
Commercial Addition Alteration Remodel Repair*
Plan Review May Be Required, Please Complete Electrical Plan Review Information Sheet
Job Address: Lo -r 4 2 P. Ertwt,.;u Viu rat- •V tt..raG` Alva thi-L-p
Building Square Footage: It'll) ea
Description of above Ow s SlA►L r- ra...��y a /INA V ILL/al- \N✓% -I
Owner Information
Mailing Address: Po cSoyc 14
City, PA, State: `era Zip: a l trf (.2..
Phone: b rs l C. k a Fax: 4--- fa......z
License Exp. 9 z Lc
Name: NA ststa r Fon_
Unit. Charoe
93.75
$113.75
$160.00
$205.00
$291.25
2.00
$5'.50
2.00
7Z50
86.25
$116.25
$131.25
75.00
69.00
75.00
50.00
50.00
93.75
80.00
86.25
27.50
57.50
86.25
43.75
Owner as defined by RCW 19.28.261: (1) Owner will occupy the structure for two years after this electrical permit is finalized. (2) Owner is required to hire an
electrical contractor if above said property is for sale, rent or lease.
After reading the above statement, hereby certify that 1 am the owner of the above named property or a licensed electrical contractor I am making the electrical
Installation or alteration in compliance wit: the electrical laws N.E.C. RCW Chapter 19.28, WAC. Chapter 296.468, The City of Port Angeles Municipal Code, and
Utility Specifications.
Signature of owner electrical contractor or electrical ct ninistrator
X Date. P 7
d
1.29919909£1.
RECE VED
JUL 6 2009
ELECTRICAL
INSPECTIONS
Total (Qty Multiplied by Unit Charge)
Contractor Information
Name. KrtR t ELk:c.1 t/AC,.
Mailing Address: 'S S. "Satz. ffs
City 5..4T1/4).m•. State: Zip: '\X Ilk
Phone: tea 4 Fax: a G`l
License Exp Ktasc.v. 1 o3z a v.l
Service/Feeder 200 Amp.
Service/Feeder 201 -400 Amp.
Service/Feeder 401 -600 Amp.
Service/Feeder 601 -1000 Amp.
Service/Feeder over 1000 Amp.
Branch Circuit W/ Service Feeder
Branch Circuit W/0 Service Feeder
Each Additional Branch Circuit
7
2.--50 Temp. Service/ Feeoer 200 Amp.
Temp. Service/Feeder 201 -400 Amp,
Temp. Service/Feeder 401 -600 Amp.
Temp. Service/Feeder 601 1000 Amp.
Portal td Portal Hourly
Sign /Outline lighting
Signal Circuit/ Limited Energy Commercial
Signal Circuit/ limited Energy 1 2 Family Dwelling
Signal Circuit/ Limited Energy. Multi- Family Dwelling
Manufactured Home Connection
Renewable Electrical Energy 5KVA System or Less
First 1300 Square Ft.
Each Additional 500 Square Fl. or Portion of
Each Outbuilding or Detached Garage
Each Swimming Pool or Hol Tub
Thermostat
Total
Cash
Check
O Credit Card G
i1ueu.go8 eoAoN
0
d60:1.0 60 90 Inf