Loading...
HomeMy WebLinkAbout729 W 5th St - BuildingpoRr. CITY OF PORT ANGELES DEPARTMENT OF COMMUNITY DEVELOPMENT BUILDING DIVISION 321 EAST 5TH STREET PORT ANGELES, WA 98362 Application Number 07 00000986 Application pin number 603724 Property Address 729 W 5TH ST ASSESSOR PARCEL NUMBER 06 30 00 0 0 9950 0000 Tenant nbr name ALICE SEWARD Application type description RE ROOF Subdivision Name Property Use Property Zoning RS7 RESDNTL SINGLE FAMILY Application valuation 4434 Owner Contractor GREG /WENDY SEWARD TOPNOTCH ROOFING GUTTER 322 9TH AVE S E #14 1235 W 9TH PUYALLUP WA 98372 PORT ANGELES WA 98362 (360) 457 5410 (360) 457 0066 Permit BUILDING PERMIT NO PR FEE Additional desc TEAR OFF AND RE ROOF Permit pin number 109637 Permit Fee 137 75 Plan Check Fee 00 Issue Date 8/27/07 Valuation 4434 Expiration Date 2/23/08 Qty Unit Charge Per Extension BASE FEE 95 75 3 00 14 0000 THOU BL -2001 25K (14 PER K) 42 00 Other Fees STATE SURCHARGE 4 50 Fee summary Charged Paid Credited Due Permit Fee Total 137 75 137 75 00 00 Plan Check Total 00 00 00 00 Other Fee Total 4 50 4 50 00 00 Grand Total 142 25 142 25 00 00 Separate Permits are required forelectrical work, SEPA, Shoreline, ESA, utilities, private and public improvements This permit becomes null and void if work or construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned fora period of 180 days after the work as commenced or if required inspections have not been requested within 180 days from the last inspection I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. n Signature of Contractor or Authorized Agent Date T \Policies \1102_15 building permit inspection record05 wpd [1 /4/2005] Date 8/27/07 Signature of Owner (if owner is builder) Date FOUNDATION: FOOTINGS SHEAR WALLS WALLS FOUNDATION DRAINAGE DOWN SPOUTS PIERS POST HOLES (POLE BLDGS.) PLUMBING UNDER FLOOR SLAB ROUGH -IN WATER LINE (METER TO BLDG) GAS LINE BACK FLOW WATER AIR SEAL WALLS CEILING FRAMING JOISTS GIRDERS SHEAR WALL/HOLD DOWNS WALLS ROOF CEILING DRYWALL (INTERIOR BRACED PANEL ONLY) T -BAR INSULATION SLAB WALL FLOOR CEILING MECHANICAL ROUGH -IN HEAT PUMP FURNACE DUCTS GAS LINE WOOD STOVE PELLET CHIMNEY MANUFACTURED HOMES FOOTING./ SLAB BLOCKING HOLD DOWNS SKIRTING PLANNING DEPT SEPARATE PERMIT #'s PARKING /LIGHTING LANDSCAPING RESIDENTIAL T\Policies\1 102 15 building permit inspection recordOS.wpd [1/4/2605] BUILDING PERMIT INSPECTION RECORD CALL 417 -4815 FOR BUILDING INSPECTIONS CALL 417 -4735 FOR ELECTRICAL INSPECTIONS CALL 417 -4807 FOR PUBLIC WORKS UTILITIES PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLAN FUL TO COVER, INSULATE OR CONCEAL AN] WORE" BEFORE INSPECTED 4ND ACCEPTED POST PERMIT IN A CONSPICUOUS LOCATION KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE. INSPECTION TYPE DATE ACCEPTED COMMENTS YES NO FINAL FINAL SEPA. ESA. SHORELINE: FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY /USE DATE YES NO COMMERCIAL ELECTRICAL LIGHT DEPT 417 -4735 ELECTRICAL LIGHT DEPT CONSTRUCTION R.W /PW/ CONSTRUCTION R.W ENGINEERING 417 -4807 I PW /ENGINEERING I FIRE 417 -4653 I 1 1 I FIRE DEPT PLANNING DEPT 417 -4750 I y 1 j I PLANNING DEPT 1 BUILDING 417 -4815 1 C XL t f +A YI'i /091 1 BUILDING DATE ACCEPTED BY, DATE ACCEPTED BY, DATE ACCEPTED Residential projects: submit two sets of plans Commercial projects: submit three sets of plans Applicant or Agent '�`'t/ n 47- A I Q 2.' C Phone Phone y, Owner's Address 7 4 e 7 l e 5 r -ro yu t va14o. Contractor/Engineer State License ti-n A/04 c gel if 04 Expires Contractor/Engineer's Address 5 (.x.) r 1 92. PROJECT ADDRESS Z (A) O r i p LEGAL DESCRIPTION Lot: Block: Subdivision. CLALLAM COUNTY PARCEL NUMBER. Owner /9 c e .e W v- Residential Multi family Commercial Repair Existing Structure(s) basement 1 floor 3`d floor Accessory Structures Existing Structure(s) TOTAL Fill out COMPLETELY and in INK. Your application, prescriptive energy form, plans, specs, and a 8' /Z" x 11" site plan MUST BE COMPLETE to be accepted for review (360) 417 -4815 FAX (360) 417 -4711 TYPE OF WORK New Constr Re -roof Addition Remodel Sign tad floor BUILDING PERMIT APPLICATION Move Demolition Other Stove Garage Deck B1AEF DESCRIPTION OF THE PROJECT P iS COMMERCIAL/RESIDENTIAL. Occupandy Group: Occupant Load. Construction Type: Sq. Ft. Proposed Structure(s) basement Sq. Ft. 151 floor Sq. Ft. 2" floor Sq. Ft. 3`d floor Sq. Ft. Accessory Structures Sq. Ft. Proposed Structure(s) TOTAL TOTAL of existing proposed structures Maximum Height of Proposed Structure(s) FOR OFFICIAL USE ONLY IA Date Rec. I� C 0 Permit o7- 1 Date Approved: Date Issued: Lir" Z., C A9 111 4 5 7 5z/ro Sq. Ft. Sq. Ft. Sq. Ft. Sq. Ft. Sq. Ft. Sq. Ft. Sq. Ft. Ft. Phone/ s J- o o h ZONING SIZE/VALUATIO SF /SF SF /SF SF /SF TOTAL VALUATION LOT COVERAGE Lot size Sq Ft. /C, ors Existing Structure(s) Sq. Ft. Footprint Proposed Structure(s) Sq. Ft. Footprint TOTAL Structure(s) Sq. Ft. Footprint Total Lot Coverage /c (Divide Total Structure(s) Sq. Ft. Footprint by Lot Size Sq. Ft.) VALUATION OF CONSTRUCTION In all cases. a valuation amount must be entered by the applicant. This figure will be reviewed and may be revised by the Building Division to comply with current fee schedules. Contact the Permit Coordinator at 417 -4815 for assistance. PLAN CHECK FEE. The plan check fee must be paid at the time the building permit application is submitted. All other permit fees are due at the time of permit issuance. EXPIRATION OF PLAN REVIEW An application for a permit for any proposed work shall be deemed to have been abandoned 180 days after the date of filing unless such application has been pursued in good faith or a permit has been issued; except that the building official is authorized to grant one or more extensions of time for additional periods not exceeding 180 days (90 days for commercial projects) each. The extension shall be requested in writing and justifiable cause demonstrated. (IRC/IBC 2006 105.3.2) I hereby certify that I have read and examined this application and know the same to be true and correct. I am authorized to apply for this permit and understand that it is my responsibility to determine what permits are required, and that I must obtain such permits prior to work. Date S.s 9 7 Applicant �`c��,U LA,/ T\FORMS \BUILDING DIVISION \BldgPermitAppl: 2006 CODE backup.wpd U Are you planning to install a lawn sprinkler system? 8/5/07 EXPIRATION DATE: 5/18/08 Company signati. )_04:F)PNORG994DA Date z3 5 c 7 k Bid prices are subject to reasonable increases due to any necessary alterations, additions, increases in material and /or labor to complete work. Homeowner will be notified of any necessary changes, which may affect cost. Property owners are responsible for obtaining any permits required for work and materials described herein. TOPNOTCH is happy to provide permit, but will add the cost to the final bill. Bid prices are applicable for 30 days* from date below, unless otherwise stated or:agreed to Please feel welcome to call if you have questions concerning this estimate /bid If bid is accepted, please sign one copy and return it to TOPNOTCH ROOFING GUTTER, at the address above. Work is scheduled upon receipt of sinned bid. Verbal aoreementa_ will not ouarantee scheduled work. References are available! TO Alice Seward 729 W 7 Port Angeles WA 98363 457 5410 FOR Re -roof same address 2 layers of composition roofing to be torn off Tear off existing roofing Clean up and disposal included. Roof with 30 -year laminated architectural composition over 30# felt Install starter course composition 9 -AF50 vents 76 of ridge cap Step flash 1 -4" neo 1- 1.5" neo Estimated cost of tear off and re -roof using the materials specified Herein labor to complete work as described and sales tax $4434 00 372.46 $4 806 46 Four thousand eight hundred six and 46/100 Plus City of PA building permit topnotchroofing a,gwest.net ESTIMATE AND BID PROPOSAL CONTRACT r' l 7h Authorized party to accept bid Y �l Date cW 7 O MATERIAL WARRANTY BY MANUFACTURER, WORK ANSHIP GUARANTEED BY LICENSED, BONDED, INSURED�ONTRACTOR PAYMENT TERMS: ONE HALF TO START WORK. BALANCE DUE IN FULL WHEN WORK IS COMPLETED ALTERNATIVE PAYMENT ARRANGEMENTS MUST BE DISCUSSED AND AGREED TO PRIOR TO THE START OF THE 30B 1 - - - - -.d ELECTRICAL PERMIT CITY OF PORT ANGELES 360-417-4735 Application Number . . . . . 18-00000388 Date 3/21/18 Application pin number . . . 593152 Property Address . . . . . . 729 W 5TH ST REPORT STATE SALES TALC ASSESSOR PARCEL NUMBER: 06-30-00-0-0-99$0-0000- type description ELECTRICAL ONLY O!1 OUl @XC/se tax form y Subdivision Name . . . . . . to the City of Port Angeles Property Use Property Zoning . . . . . . . RS7 RESDNTL SINGLE FAMILY 1 l �LoMdon � 05(12) Application valuation . . . . 0 Application desc - PV system ----------------------------------7 ----------------------------------------- Owner Contractor ------------------------ WENDY M GASTON ------------------------ SMART ENERGY TODAY, INC 729 W 5TH ST 2120 STATE AVE NE STE 103 PORT ANGELES WA 98363 OLYMPIA WA 98506 (360) 461-5573 (888) 405-8689 ---------------------------------------------------------------------------- Permit . . . . . . ELECTRICAL ALTER RESIDENTIAL Additional desc =' Permit Fee . . . . 102.00 Pian Chdck Fee .00 Issue Date . . . . 3/21/18 Valuation . . . . 0 Expiration Date . 9/17/18 Qty Unit Charge Per Extension 1.00 102.0000 ECH EL -RENEWABLE 5-KVA OR LESS 102.00 ----------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 102.00 102.00 .00 .00 Plan Check Total .00 .00 .00 .00 Grand Total 102.00 102.00 .00 .00 INSPECTION TYPE DITCH SERVICE ROUGH -IN FINAL COMMENTS: DATE: RESULTS: PERMIT WILL EXPIRE SIX (6) MONTHS FROM LAST INSPECTION Signature of owner or Electrical Contractor X INSPECTOR: Date: CITY OF PORT ANGELES PERMIT APPLICATION Building Division/Electrical Inspections 321 East Fifth Street— P.O. Box 1150 / Port Angeles Washington, 98362 Ph: (360) 417-4735 Fax: (360) 417-4711 Date: 31_15L18 V 1 & 2 Single Family Dwelling * Plan Review May Be Required, Please Complete Electrical Plan Review Information Sheet JobAddress:..Z29 W 5th ST Port Angeles. WA 983F'; Building Square Footage: ,,ru, ,'�,r� R Description of above-SingiP family reciriPnre I RECE, E(ECI lAd;GoFCTtjj Owner Information Contractor Information Name, We A GatitoD.--_,-,...,,_„_ Name: Smart Enerav Todav Mailing Address: Z29 W 5th St Mailing Address: 1001 Cooper Point Rd SW Ste. 140-290 =a__—_ State: W_ Zip 9R363_ City: -P-=I- --- City: Q�ia __ _ ___ State: WA - Zip: -38542 — Phone. -(36 ) 41 57-3 Fax: _ . _ Phone: -.360-63Z-4343 Fax License # / Exr _ — License # /.Exp. ,gyp I�ABTE_U69RJ Item Unit Charae, Qtt Total (Ctv Multiplied by Unit Chanel, Service/Feeder 200 Amp. $120.00 $ Service/Feeder 201.400 Amp. $ 146.00 $ Service/Feeder 401-600 Amp $ 205.00 $ Service/Feeder 601-1000 Amp. $ 262.00 — $ Service/Feeder over 1000 Amp. $ 373.00 $ Branch Circuit W/ Service Feeder $ 5.00 $ Branch Circuit W/O Service Feeder $ 63.00 $__ - Each Additional Branch Circuit $ 5.00 $ Branch Circuits 1.4 $ 75.00 $-- _Temp. Temp. Service/ Feeder 200 Amp. $ 93.00 $ Temp. Service/Feeder 201-400 Amp. $ 110.00 _. _.__ _ $ Temp. Service/Feeder 401-600 Amp. $ 149.00 $_ Temp. Service/Feeder 601-1000 Amp . $168.00 ___ $ Portal to Portal Hourly $ 96.00 $ Signal Circuit! Limited Energy - 1 & 2 Family Dwelling $ 64.00 $____ Manufactured Home Connection $120.00 $. _ Renewable Electrical Energy - 5KVA System or Less $ 102.00.- $._102.00' Thermostat $ 56.00 $ _ Note: $5.00 for each additional T-Stat NEW CONSTRUCTION ONLY:, First 1300 Square Ft. $120.00 $ Each Additional 500 Square Ft. or Portion of $ 40.00 —____ $_ Each Outbuilding or Detached Garage $ 74.00 $ Each Swimming Pool or Hot Tub $ 110.00 $ $ 10200 Total Owner as defined by RCW.19.28.261: (1) Owner will occupy the structure for two years after this electrical permit is finalized. (2) Owner is required to hire an electrical contractor if above said property is for sale, rent or lease. Permit expires after six months of last inspection. After reading the above statement, I hereby certify that I am the owner of the above named property or a licensed electrical contractor. I am making the electrical installation or alteration in compliance with the electrical laws, N.E.C., RCW. Chapter 19.28, WAC. Chapter 296-46B, The City of Port Angeles Municipal Code, and Utility Specifications and PAMC 14.05.050 regarding Electrical Permit Applications. Signature of owner, electrical contractor or electrical administrator: ❑ Cash ltd' Check ❑ Credit Card # x: IZ�lici c�C/Gd� Date: 3115120-18 ovovzolz Application and Checklist for Roof Mounted Residential Solar Panels Project Information: Property Owner Name: Project Address: Contractor Name Contractor Phone: PV system description Wendy Gaston 729 W 5th St Port Angeles, WA 98363 Smart Energy Today 360-637-4343 Installation of residential rooftop pv solar system 6kW Phone: 360-461-5573 Registration # Mfg /model # of major equip: iTek Energy/iT300-SE - AP Systems/APS-YC500A Per WAC 51-51-2300, if the answer to the following questions is "yes" a building permit will be issued for simple (10-15kw output) PV systems without further engineering. Section M2302.2.1— Where solar panels are installed on roofs, the roof structure shall be deemed adequate to support the load of the rooftop if all of the following are met: Yes No 1. PV system is designed and proposed for a single family or detached accessory structure EO ❑ 2. Will the photovoltaic panels and modules and supporting structure shall be constructed of ® ❑ noncombustible materials or fire -retardant treated wood equivalent to that required for the roof construction. The installation shall meet the requirements of the International Fire Code as amended by WA State. PV modules are listed and labeled with a fire classification in accordance with UL 1703 3. The PV system is designed for the wind speed of the local area and will be installed per the manufacturer's specifications. 9 ❑ 4. The ground snow load does not exceed 70 pounds per square foot. The PV system is designed [� ❑ for the wind speed of the local area, and will be installed per the manufacturer's specifications. 5. Total dead load of modules, supports, mountings, raceways and all other appurtenances weigh R ❑ no more than four pounds per square foot. Enter total dead load of system (lbs/ftl): 6. Supports for solar modules are installed to spread the dead load across as many roof -framing W ❑ members as needed to ensure that no point load exceeds fifty (50) pounds. Modules are mounted no higher than 18" above the surface of the roofing to which they are affixed and do not exceed the highest point of the roof unless approved by the local jurisdiction. NOTE: If site inspection indicates a concern that the roof structure is not adequate to support the PV module(s), engineering may be required prior to final of the permit. As the property owner or authorized representative of the above listed property, I attest that all information in this checklist is accurate to the best of my knowledge. Applicant Signature: 71 � �C�Ge� I Date: 3/15/2018 Applicant Name (Please Print): Relationship to Property Owner: SCOPE OF WORK GENERAL NOTES: PHOTOVOLTAIC SYSTEM SUMMARY 1 AN INVERTER OR AN AC MODULE IN AN INTERACTIVE PHOTOVOLTAIC SYSTEM SHALL AUTOMATIC ALL DE -ENERGIZE ITS OUTPUT TO THE CONNECTED ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK UPON LOSS OF VOLTAGE IN THAT SYSTEM AND SHALL REMAIN IN SYSTEM SIZE DC STC -6 00 KW THAT STATE UNTIL THE ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK VOLTAGE HAS BEEN RESTORED (NEC 690361) 2 ALL EXTERIOR ELECTRICAL METALLIC TUBING(EMT) CONDUIT FITTING SHALL BE RAIN TIGHT THREAD -LESS COMPRESSION TYPE MODULES 20 ITEK ENERGY 17300 -SE MODULE ( ) 3 MODULES AND SUPPORT STRUCTURES SHALL BE GROUNDED MODULE MX POWER (P/MAX) 30OW 4 NAMEPLATES SHALL BE PROVIDED FOR ALL CIRCUITS IN THE SERVICE DISTRIBUTION AND POWER DISTRIBUTION SWITCH BOARDS, INVERTER (10) APS-YC500A PANEL BOARDS, DISCONNECTING SWITCHES, TERMINAL CABINETS, ETC ALL NAMEPLATES SHALL BE PERMANENTLY ATTACHED AND BE MICROINVERTER OF SUFFICIENT CAPACITY TO WITHSTAND THE WEATHER ARRAY TILT 20' 5 JUNCTION BOX/COMBINER BOX HAVE TO USE COMPRESSION TYPE STRAIN RELIEF POSITIONED FOR APPROPRIATE WATER RUN OFF AZIMUTH 122°/212' 6 CONDUIT RUNS SHALL BE PROVIDED WITH SUFFICIENT WEATHERPROOF PULL BOXES OF JUNCTION BOX/COMBINER BOXES PER ELECTRICAL INFORMATION APPROPRIATE NEC REQUIREMENTS COUNTY CLALLAM 7 SEE PROVIDED CUT SHEETS FOR ADDITIONAL EQUIPMENT SPECIFICATIONS 8 WIRING MATERIALS SHALL BE SUITABLE FOR THE SUN EXPOSURE AND WET LOCATIONS FIELD APPLIED PROTECTIVE COATINGS ARE UTILITY COMPANY CITY OF PORT ANGELES MAIN SERVICE AMPERAGE 200A NOTACCEPTABLE 9 JUNCTION, PULL AND OUTLET BOXES LOCATED BEHIND MODULES SHALL BE SO INSTALLED THAT THE WIRING CONTAINED IN THEM CAN BE RENDERED ACCESSIBLE DIRECTLY OR BY DISPLACEMENT OF MODULE(S) SECURED BY REMOVABLE FASTENERS AND CONNECTED BUILDING INFORMATION TWO STORY HOUSE ROOF COMPOSITE SHINGLE BY A FLEXIBLE WIRING SYSTEM (NEC 690 34). NUMBER OF LAYERS 01 10 IN AN UNDERGROUND PHOTOVOLTAIC SYSTEM, THE POWER SOURCE SHALL BE LABELED WITH THE FOLLOWING WARNING AT EACH ANNUAL WIND MPH JUNCTION BOX, COMBINER BOX, DISCONNECT AND DEVICE WHERE THE UNGROUNDED CIRCUITS MAYBE EXPOSED DURING SERVICE " AVERAGE SPEED 110 WARNING -ELECTRIC SHOCK HAZARD THE CURRENT CIRCUIT CONDUCTORS OF THIS PHOTOVOLTAIC POWER SYSTEM ARE GROUND SNOW LOAD N/A UNGROUNDED BUT MAY BE ENERGIZED WITH THE RESPECT TO GROUND DUE TO LEAKAGE PATHS AND/OR GROUND FAULTS "(NEC 690 35(F)) CODE SUMMARY 11 ALL PHOTOVOLTAIC MODULES AND ASSOCIATED EQUIPMENT AND WIRING MATERIAL SHALL BE PROTECTED FROM ANY PHYSICAL AGE 2015WASHINGTON STATE BUILDING CODE (2015 IBC) 12 ALL ELECTRICAL DEVICES AND UTILIZATION EQUIPMENT SHALL BE LISTED BY AN APPROVED TESTING AGENCY 2015 WASHINGTON STATE ENERGY CODE (2015 IECC) 13 OUTDOOR EQUIPMENT SHALL BE AT LEAST NEMA 3R RATED 2015 WASHINGTON STATE RESIDENTIAL CODE 14 ALL SPECIFIED WIRING IS BASED ON THE USE OF COPPER (2015 INTERNATIONAL RESIDENTIAL CODE WASHINGTON 15 CONTRACTOR SHALL OBTAIN ELECTRICAL PERMITS AND SHALL COORDINATE ALL INSPECTION, COMMISSIONING AND ACCEPTANCE AMENDMENTS 2014 WAC51-51-2300 SECTION M2302) WITH THE CLIENT, UTILITY CO AND CITY INSPECTORS AS NEEDED 2017 WAC 296-46B (2017 NEC) 16 DRAWINGS ARE DIAGRAMMATIC ONLY, ROUTING OF RACEWAYS SHALL BE AT THE OPTION OF THE CONTRACTOR UNLESS OTHERWISE 2015 WASHINGTON STATE MECHANICAL CODE(2015 UMC) NOTED AND SHALL BE COORDINATED WITH OTHER TRADE 2015 WASHINGTON STATE PLUMBING CODE (2015 UPC) 17 IF DISTANCES OF CABLE RUNS ARE DIFFERENT THAN SHOWN, THE CONTRACTOR SHALL NOTIFY ELECTRICAL ENGINEER TO VALIDATE 2015 WASHINGTON STATE FIRE CODE (2015 IFC)THE WIRE SIZE FINAL DRAWINGS WILL BE RED -LINED AND UPDATED AS APPROPRIATE, 18 WHENEVER A DISCREPANCY IN QUANTITY OF EQUIPMENT, ARISES ON THE DRAWINGS OR SPECIFICATIONS, THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AND INSTALLING ALL MATERIAL AND SERVICES REQUIRED BY THE STRICTEST CONDITIONS NOTED ON THE DRAWINGS OR IN THE SPECIFICATIONS TO ENDURE COMPLETE COMPLIANCE AND LONGEVITY OF THE OPERABLE SYSTEM SHEET INDEX REQUIRED BY THE ARCHITECT/ENGINEER 19 ALL BROCHURES, OPERATION MANUALS, CATALOGS, SHOP DRAWINGS, ETC SHALL BE HANDED OVER TO THE OWNER'S PV -0 COVER SHEET REPRESENTATIVE AT THE COMPLETION OR WORK PV -1 PLOT PLAN WITH ROOF PLANS 20 ALL WIRING CONCEALED IN WALL AND CEILING SPACES SHALL BE IN METAL CONDUIT PV -2 ROOF PLAN WITH MODULES 21 THE SEISMIC BRACING AND ANCHORAGE OF ELECTRICAL CONDUITS SHALL BE IN ACCORDANCE WITH THE "SMACNA"-GUIDLINES FOR PV- 3 ATTACHMENT DETAIL SEISMIC RESTRAINS OF MECHANICAL SYSTEMS AND PLUMING PIPING SYSTEMS PV4 ELECTRICAL LINE DIAGRAM 22 ALL OF THE LISTED SYSTEMS REQUIRED THAT THE SEISMIC LATERAL FORCE F INCLUDING CONSIDERATION OF a"P AND OP BE PV -5 PLACARDS DETERMINED AT EACH LEVEL OF THE BUILDING SO THAT BRACE SPACING CAN BE CALCULATED THE DISTRICT STRUCTURAL ENGINEER PV -6+ MANUFACTURER SPEC SHEET CAN APPROVE THE SEISMIC LATERAL FORCE DETERMINATION 23 A COPY OF THE CHOSEN BRACING SYSTEM(S) INSTALLATION GUIDE/MANUAL SHALL BE ON THE JOB SITE PRIOR TO STARTING THE INSTALLING OF HANGERS AND/OR BRACES 24 WHEN INSTALLING DRILLED -IN ANCHORS AND/OR POWDER DRIVEN PINS IN EXISTING NON -PRESTRESSED REINFORCED CONCRETE, USE CARE AND CAUTION TO AVOID CUTTING OR DAMAGING THE REINFORCED BARS WHEN INSTALLING THEM INTO EXISTING PRE -STRESSED CONCRETE TENDONS BY USING A NON-DESTRUCTIVE METHOD PRIOR TO INSTALLATION EXERCISE EXTREME CARE AND CAUTION TO AVOID CUTTING OR DAMAGING THE TENDONS DURING INSTALLATION MAINTAIN A MINIMUM CLEARANCE OF ONE INCH BETWEEN THE REINFORCEMENT AND THE DRILLED -IN ANCHOR 25 THE WORKING CLEARANCES AROUND THE EXISTING ELECTRICAL EQUIPMENT AS WELL AS THE NEW ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN ACCORDANCE WITH NEC 110 26 26 CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT (NEC 300 601, 310 8 D 27 GROUNDING BUSHINGS ARE REQUIRED AROUND PRE -PUNCHED CONCENTRIC KNOCKOUTS ON THE DC SIDE OF THE SYSTEM (NEC 250 97) 28 THE GROUNDING ELECTRODE CONDUCTOR MUST BE PROTECTED FROM PHYSICAL DAMAGE IF SMALLER THAN M6 COPPER WIRE (NEC 250 64 B) 29 GROUNDING ELECTRODE CONDUCTOR WILL BE CONTINUOUS, EXCEPT FOR SPLICES OR JOINTS AT BUSBARS WITHIN LISTED EQUIPMENT (NEC 25064 C) 30 RACEWAY FOR GROUNDING ELECTRODE CONDUCTOR SHALL BE BONDED AT EACH END (NEC 25064 (E) 31 WHERE ALL TERMINALS OF THE DISCONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, A SIGN WILL BE PROVIDED WARNING OF THE HAZARD PER NEC 69017 34 EACH UNGROUNDED CONDUCTOR OF THE MULT-WIRE BRANCH CIRCUIT WILL BE IDENTIFIED PER PHASE AND SYSTEM PER NEC210 5 32 CIRCUITS OVER 250V TO GROUND SHALL COMPLY WITH NEC250 97 8 250 92 (B) 8 LAMC 93 250 97 33 DC CONDUCTORS EITHER DO NOT ENTER THE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR ENCLOSURES TO THE FIRST ACCESSIBLE DC DISCONNECTING MEANS PER NEC 690 31 (E), LAMC 93690 31 (E) 34 ALL METALLIC FRAME RAILS AND OTHER CURRENT CARRYING METALLIC COMPONENTS (CONDUIT, JUNCTION & PULL BOXES, RACEWAY, ETC) SHALL BE SOLIDLY GROUNDED PER THE MANUFACTURER'S INSTALLATION INSTRUCTIONS LAMC 93 690 110 3 8 93 110 3(8) 35 SCREWS, NUTS, BOLTS 8 WASHERS THAT ATTACH EQUIPMENT GROUNDING LUGS SHALL BE STAINLESS STEEL LAMC 93 110 3(B) 36 NO PIPING, DUCTS OR EQUIPMENT FOREIGN TO ELECTRICAL EQUIPMENT SHALL BE PERMITTED TO BE LOCATED WITHIN THE DEDICATED SPACE ABOVE THE ELECTRICAL EQUIPMENT 37 ALL FIELD INSTALLED JUNCTION, PULL AND OUTLET BOXED LOCATED BEHIND MODULES OR PANELS SHALL BE ACCESSIBLE DIRECTLY OR BY DISPLACEMENT OF A MODULE (S) OR PANEL (S) SECURED BY REMOVABLE FASTENERS 38 REMOVAL OF A DWP-INTERACTIVE INVERTER OR OTHER EQUIPMENT SHALL NOT DISCONNECT THE BONDING CONNECTION BETWEEN THE GROUNDING ELECTRODE CONDUCTOR AND THE PHOTOVOLTAIC SOURCE AND/OR OUTPUT CIRCUIT GROUNDED CONDUCTOR 39 THE ROOF MOUNTED PHOTOVOLTAIC MODULES, PANELS, OR SOLAR VOLTAIC ROLL ROOFING MATERIAL SHALL HAVE THE SAME OR BETTER LISTED FIRE -RESISTANCE RATING THAN THE BUILDING ROOF -COVERING MATERIAL 40 ALL ROOF MOUNTED CONDUIT WILL BE A MINIMUM 6" OFF THE ROOF SURFACE Smart Energy Today Inc."--' SOLAR 1001 Cooper Point Rd SW, Suite 140-290 Olympia, WA 98502 Phone 888-405-8689 Fax 855-350-9430 support@smartenergytoday net REVISIONS DESCRIPTION DATE REV INITIAL 0315-2019 00 Signature with Seal PROJECT NAME 8 ADDRESS 2 VICINITY MAP PV -0 SCALE.NTS SHEET NAME COVER SHEET SHEET SIZE ANSI B 1111 X 17" SHEET NUMBER PV -0 0 ROOF ACCESS POINT SHALL BE LOCATED IN AREAS THAT DO NOT REQUIRE THE PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS WINDOWS OR DOORS, AND LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION IN LOCATIONS WHERE THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES OR SIGNS. (E) MAIN SERVICE PANEL (INSIDE) ROOF #2 (8) iTEK ENERGY iT300-SE MODULE (4) APS-YC500A INVERTER 'EVERY 2 MODULES WITH 1 MICRO INVERTER 1 PLOT PLAN WITH ROOF PLAN PV -1 SCALE 3/64" = 1'0" 0T ROOF ACCESS POINT ROOF#1 (6) iTEK ENERGY iT300-SE MODULE (3) APS-YC500A INVERTER 'EVERY 2 MODULES WITH 1 MICRO INVERTER ROOF #3 (6) iTEK ENERGY IT300-SE MODULE (3) APS-YC500A INVERTER "EVERY 2 MODULES WITH 1 MICRO INVERTER PROJECT NAME 8 ADDRESS Z 0 U) Q Z LU W J z LO rC2 co 0ri a. CID, I.-: Go �0) Q LLI Z In 3 0 a rn N P - SHEET NAME PLOT PLAN & ROOF PLAN SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV -a Smart Energy Today lnI N SOLAR -* ■ 1001 Cooper Point Rd SW, Suite 140-290 ■ Olympia, WA 98502 Phone 888-405,8689 Fax 855-350-9430 support@ smartenergytoday net REVISIONS DESCRIPTION DATE INITIAL 03.15-2018 IREV W Signature with Seal ROOF ACCESS POINT ROOF#1 (6) iTEK ENERGY iT300-SE MODULE (3) APS-YC500A INVERTER 'EVERY 2 MODULES WITH 1 MICRO INVERTER ROOF #3 (6) iTEK ENERGY IT300-SE MODULE (3) APS-YC500A INVERTER "EVERY 2 MODULES WITH 1 MICRO INVERTER PROJECT NAME 8 ADDRESS Z 0 U) Q Z LU W J z LO rC2 co 0ri a. CID, I.-: Go �0) Q LLI Z In 3 0 a rn N P - SHEET NAME PLOT PLAN & ROOF PLAN SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV -a MODULE TYPE, DIMENSIONS & WEIGHT - AC COMBINER PANEL NUMBER OF MODULES = 20 MODULES MOUNTING SYSTEM AND MANUFACTURER MODULE TYPE = iTEK ENERGY IT300-SE MODULE 31 „ MODULE WEIGHT = 43 LBS / 19.5 KG. TOTAL WEIGHT OF MODULES MODULE DIMENSIONS = 65.94"x 39.41" = 18 05 SF LBS UNIT WEIGHT OF ARRAY = 2.38 PSF MODULE WEIGHT X NUMBER OF MODULES 143 X 20 MODULES 86000 ROOF DESCRIPTION 1CLAMPS 2 5 LBS X 50 POINTS 125 DO (ROOF TYPE COMPOSITE SHINGLE C 1ROOF LAYER 1LAYER ROOF#2 CRAFTER FRAMING CONVENTIONAL WEIGHT PER ATTACHMENT POINT (BIC) -NOT EXCEED 45 LBS 1970 (8) iTEK ENERGY iT300-SE MODULE ROOF ROOF TILT AZIMUTH MAXIMUM SPACING BETWEEN POINTS ON A RAFTER SPACING IS 24' ON RAIL CENTER 4-0 (4) APS-YC500A INVERTER 1 F ITOTAL SURFACE AREA OF PV MODULES 1805 SOFT X 20 MODULES 1 36100 •EVERY 2 MODULES WITH 1 MICRO INVERTER #120° 122, (BU'ED #2 20° 122° (N) SOLAR AC COMBINER PANEL #3 20° 212° EQUIPMENT QTY I DESCRIPTION i (N) NON-FUSED AC DISCONNECT ARRAY AREA (N) PV PRODUCTION METER # OF ARRAY ROOF ROOF (E) UTILITY METER (INSIDE) ROOF MODULES AREA AREA AREA COVERED (Sq Ft.) (Sq. Ft.) BY ARRAY (%) (E) MAIN SERVICE PANEL (INSIDE) #1 6 1083 179.28 6041 1 #2 8 1444 305.00 4734 1 #3 6 108.3 210.42 51.47 1 MOUNTING CALCULATIONS - AC COMBINER PANEL A MOUNTING SYSTEM AND MANUFACTURER SPIDER RAX BLACK WIDOW COMPOSITE 31 „ B TOTAL WEIGHT OF MODULES 98500 LBS MODULE WEIGHT X NUMBER OF MODULES 143 X 20 MODULES 86000 LBS 1CLAMPS 2 5 LBS X 50 POINTS 125 DO iT300-SE C TOTAL NUMBER OF ATTACHMENTS POINTS 50 --- - CONDUIT D WEIGHT PER ATTACHMENT POINT (BIC) -NOT EXCEED 45 LBS 1970 LBS E MAXIMUM SPACING BETWEEN POINTS ON A RAFTER SPACING IS 24' ON RAIL CENTER 4-0 1 F ITOTAL SURFACE AREA OF PV MODULES 1805 SOFT X 20 MODULES 1 36100 SOFT WEIGHT OF PV MODULE ON 985 DO LBS 1381 00 SO FT I 213 G IROOF PSF (BU'ED BILL OF MATERIALS EQUIPMENT QTY I DESCRIPTION i SOLAR PV MODULE 20 liTEK ENERGY 17`300 -SE IAC COMBINER PANEL 1 100A SOLAR AC COMBINER PANEL, 240V INVERTER 10 APS-YC500A IAC DISCONNECT 1 30A NON-FUSED, 240V NEMA 3R, UL LISTED ATTACHMENT 50 SPIDER RAX BLACK WIDOW COMPOSITE COUPLING I 28 COUPLING AT EACH POINT IGROUNDING LUG Ii 4 GROUNDING LUG LEGEND JB -JUNCTION BOX ACP - AC COMBINER PANEL ACD -AC DISCONNECT 31 „ PVM - PRODUCTION METER uM - UTILITY METER MSP -MAIN SERVICE PANEL Obi iTEK ENERGY iT300-SE o - VENT (ROOF OBSTRUCTION) c�0 MODULES --- - CONDUIT 0 iTEK ENERGY iT300-SE MODULE APS-YC500AINVERTER IERY 2 MODULES WITH 1 MICRO INVERTER ROOF PLAN & MODULES SCALE: 1/8" = 1'-0" Smart Energy Today Inca' SOLAR 1001 CooperPoint Rd SW, Suda 140-290 Olympia, WA 98502 Phone 888-405-8689 Fa, 855-350-9430 support@smartenergytoday net REVISIONS DESCRIPTION DATE REV INITIAL 03.152018 00 Signature with Seal PROJECT NAME & ADDRESS U) Z 19 c) ''0 0 r- vJ (1) dM } ~ co =Qz Z P: R: Lu 0 a 01l r SHEET NAME ROOF PLAN & MODULES SHEET SIZE ANSI B - 11" X 17" SHEET NUMBER PV -2 il 1 ATTACHMENT DETAIL PV -3 SCALE1" = V-0" 3/8" X 3" HEX BOLT WITH 3/8" SERRATED FLANGE NUT WITH 3/8" STAR WASHERS (STAINLESS STEEL) TOP CLAMP BOTTOM CLAMP 3/8" X 1" HEX BOLT 3/8" SERRATED FLANGE NUT WITH 3/8" STAR WASHERS (STAINLESS STEEL) ALUMINUM L -FEET 3/8" X 3/4" HEX BOLT 3/8" SERRATED FLANGE NUT WITH 3/8" STAR WASHERS (STAINLESS STEEL) BASE PLATE 2 ATTACHMENT DETAIL (enlarged view) PV -3 SCALE' NTS PV MODULES SPIDER RAX BLACK WIDOW COMPOSITE (ONE RAIL) FLASHINGS 1/2" PLYWOOD ' •' USE A CORDLESS IMPACT WRENCH FITTED WITH A 1/4" SOCKET TO SECURE THE MOUNT TO THE ROOF DECK USING ` (STAINLESS STEEL 6 X 1-1/4") SCREWS INCLUDED WITH THE BLACK WIDOW MOUNT. TORQUE ALL SCREWS TO 14 FT -LBS. " ` NOTE WASHINGTON: 6 SCREWS CALIFORNIA: 5 SCREWS FLORIDA: 8 SCREWS HAWAII: 8 SCREWS TEXAS: 6 SCREWS Smart Energy Today Inc." SOLAR 1001 Cooper Point Rd SW, Suite 140-290 Olympia, WA 98502 Phone: 888-405-8689 Fax 855-350-9430 supportiCemartenerg,400ay net REVISIONS DESCRIPTION I OATE REV INITIAL 03-15-2011 00 Signature wth Seal PROJECT NAME 6 ADDRESS ZLU -JM O 0 r- Q U` a�a } M H 00 = Q W ZX30 a rn N r SHEET NAME ATTACHMENT DETAIL SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV -3 (20) ITEK ENERGY 17300 -SE MODULE WIRE WIRE WIRE TEMP WIRE � TEMP CONDUIT WIRE TERMINAL INVERTER. STRING GRND GRND WIRE (2) STRINGS OF 6 MODULES TAG # CONDUIT QTY GAUGE: WIRE TYPE RATING: AMP DE -RATE: FILL: OCP: 75°C RATING: QTY: NOC: NEC: AMPS SIZE TYPE (1) STRING OF 8 MODULES CONNECTED IN SERIES PER STRING _ O OPEN AIR 6 #12 TRUNK CABLE 90"C 30 X 1.04 X 080 = 24.96A 25 4 x 2.08 x 1.25 = 10.4A #8 THHN SYSTEM SIZE -20x ITEK 30OW=600kW I O 3/4"PVC 6 #10 THHN 90°C 40 X 0.82 X 0.80 = 26.24A 35 4 x 2.08 x 1.25 = 10.4A #8 THHN O3 3/4" PVC 3 #10 THHN 90°C 40 X 1.04 X 1 = 41.60A 35 10 x 2.08 x 1.25 = 26.OA #8 THHN SOLAR MODULE SPECIFICATIONS MICRO -INVERTER SPECIFICATIONS AMBIENT TEMPERATURE SPECS MANUFACTURER / MODEL# ITEK ENERGY IT300-SEI MANUFACTURER /MODEL* APS YC -500A MICRO -INVERTER I RECORD LOW TEMP -- VMP 32 9V I NOMINAL OUTPUT CURRENT 2.08 AMP AMBIENT TEMP (HIGH TEMP 2%) 25' IMP 9.0A J RATED OUTPUT POWER 240 VAC I CONDUIT HEIGHT 0.5" VOC 39 BV ROOFTOPTEMP 4T ISC 9 7ANUMBER OF CURRENT MODULE DIMENSION 65 94"L x 39 41"W x 1.9T'D (In Inch) PERCENT OF CARRYING CONDUCTORS IN VALUES RACEWAY, CALBLE OR EARTH MODULE TEMPERATUREI -0 29%/°C .80 4-6 COEFFICIENT OF Voc I 70 7-9 I .50 10-20 PHOTOVOLTAIC SYSTEM CONTAINS MICRO -INVERTERS EQUIPPED WITH AUTOMATIC, RAPID SHUTDOWN IAW NEC 690 56 (C) 1 4 MICROINVERTERS WITH 8 MODULES IN BRANCH CIRCUIT 1 I MICROINVERTERS WITH 6 MODULES BRANCH CIRCUIT 2 """""" 1111 111111E X111 1111111 1-�-M—IC�-OFN-V-E-kTER�7-W-1-TH-6-M-OD—ULtS IN i::::INI:.I ��u��� � IINIINik INN 1 1 ELECTRICAL LINE DIAGRAM APS -YC -500A PV -4 I SCALE:NTS MICRO -INVERTER TO UTILITY GRID L1 L2 N BI-DIRECTIONAL UTILITY METER 1 -PHASE, 3-W 120V1240V METER NO 77504331M UTILITY METER BRAND WESTINGHOUSE METER FREQUENCY FM2S 60HZ/240V IN VICE (Et VICE MAIN SERPANEL 200A E AC DISCONNECT VISIBLE LOCKABLE AC NON-FUSED DISCONNECT WITH PV SOLAR COMBINER EXTERIOR HANDLE, PV PRODUCTION METER JUNCTION BOX 240V, 30AMP NON-FUSED 20V AC IWHZ, 1 -PHASE, PANEL 100A, 240V NEMA 3R, 600V NEMA 3R, UL LISTED 3 -WIRE, 125A MAXIMUM, t00A CONTINUOUS 5A OL2 3M LINE LOAC IN III N ^� 11 L2 "INSTALL NEW 2P, 30A 0 0—. 3 3 GEc — SOLAR BREAKER AT THE E 3 GROUNDING MAND IN BUSS BAR IN L SERVICE PANE" ELECTRODE SYSTEM 15A L1 L2fN SERVICE INFO UTILITY PROVIDER: CITY OF PORT ANGELES MAIN SERVICE VOLTAGE: 240V MAIN PANEL BRAND: BRYANT MAIN SERVICE PANEL: 200A MAIN SERVICE LOCATION: NORTH WEST SERVICE FEED SOURCE: OVERHEAD Smart Energy Today Inc.' SOLAR 1001 Cooper Paint Rd SW, Suite 140-290 Olympia, WA 98502 Phone 888-405-8689 Fax 855-350-9430 Support@ smartenergyto day net REVISIONS DESCRIPTION DATE EV R INITIAL 03-15-2018 00 � I I I Signature with Seal PROJECT NAME 8 ADDRESS N Z LU F) O 10 H < (� a�0 ~ CO mLU LJJ U' _ � a SHEET NAME ELECTRICAL LINE DIAGRAM SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV -4 TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY LABEL LOCATION DISCONNECT, POINT OF INTERCONNECTION (PER CODE NEC 890 51 IFC 60511 31(1) LABEL LOCATION AC DISCONNECT, POINT OF INTERCONNECTION (PER CODE NEC 690 54) I WARNING ELECTRIC SHOCK HAZARD TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION LABEL LOCATION AC DISCONNECT, POINT OF INTERCONNECTION PER CODE NEC 690 13(8) I WARNING LABEL LOCATION POINT OF INTERCONNECTION, SOLAR BREAKER PER CODE NEC 705 12S)(2)(c) LABEL LOCATION POINT OF INTERCONNECTION, SOLAR BREAKER PER CODE NEC 70512(B)(2)(c) _ ISOURCE .I - Smart SOLAR POWE CAUTION LABEL LOCATION' JUNCTION 80% (PER CODE NEC 690 31(G)(3)(4) POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE 1001 Cooper Point RU SW. FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN Swte 140-290 Olymia, WA 98502 AT: ®MAIN SERVICE PANEL & UTILITY METER Phonep888-405-8689 PRODUCTION METER Fax 855-350-9430 O VA NON-FUSED AC DISCONNECT support® smartenerg*oday net - SOLAR AC COMBINER REVISIONS DESCRIPTION DAiE REV 1 r�l•�,� C���•� � I,' i•71� I I I I I I I I i IN PT o3-saom I o0 LABEL LOCATION Signature with Seal POINT OF INTERCONNECTION, SOLAR BREAKER(S), ' PV COMBINER (PER CODE NEC 690 13 (B)) • WARNING I I I I I U J . 1 TURN OFF PHOTOVOLTAIC 1 AC DISCONNECT PRIOR TO PROJECT NAME 8 ADDRESS WORKING INSIDE PANEL LABEL LOCATION POINT OF INTERCONNECTION, SERVICE PANEL, PV COMBINER - (PER CODE NEC 110.27 (C)) (E) MAIN SERVICE PANEL W (INSIDE) LLI - (E) UTILITY METER O -. (N) PV PRODUCTION METER Z LO (N) NON-FUSED AC DISCONNECT'� Q 1Q L?LABEL LOCATION (N) PV SOLAR COMBINER vi F j co POINT OF INTERCONNECTION Q O (PER CODE NEC 705 12(0)(3) NEC 690 59) d NET METER, PRODUCTION METER -- --CID (PER AHJ, UTILITY OPERATIONS) ELECTRICAL NOTES 1.-: 02 c 1 ) ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND Z H 3 Z AU PRUUTUT110IN 4 LABELED FOR ITS APPLICATION. Q 2.) ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V LV d LABEL LOCATION AND 90 DEGREE C WET ENVIRONMENT PRODUCTION METER 3.) WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS r SHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY. ,LI'a'�AWAM 4.) WORKING CLEARANCES AROUND ALL NEWAND EXISTING LABEL LOCATION ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26. (NET METER) 5.) DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF PER CODE NEC 705 12(0)(3) NEC 690 59 SYSTEMS. CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS, SUPPORTS, FITTINGS AND ACCESSORIES TO FULFILL ADHESIVE FASTENED SIGNS APPLICABLE CODES AND STANDARDS SHEET NAME • THE LABEL SHALL BE SUITABLE FOR THE ENVIRONMENT 6.) WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS PLACARDS WHERE IT IS INSTALLED ARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEM WHERE REQUIRED ELSEWHERE IN THIS CODE, ALL ACCORDINGLY. FIELD 7.) ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY SHEET SIZE APPLIED LABELS, WARNINGS, AND MARKING SHOULD LABELED AND READILY VISIBLE. COMPLY WITH ANSI Z535 4 [NEC 110 21(B) FIELD ANSI B MARKING) 8) MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN • ADHESIVE FASTENED SIGNS MAY BE ACCEPTABLE IF MODULE FRAME AND MODULE SUPPORT RAIL, PER THE 11 a X 17" PROPERLY ADHERED VINYL SIGNS SHALL BE WEATHER GROUNDING CLIP MANUFACTURER'S INSTRUCTION. RESISTANT [IFC 605 11 1 3] SHEET NUMBER 9.) MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS I COPPER G E.C. VIA WEEB LUG OR ILSCO GBL-4DBT LAY -IN LUG. PV_C� 10.) THE POLARITY OF THE GROUNDED CONDUCTORS IS NEGATIVE quality that exceed performance expectations at an affordable price. Connectwith us: www.itekenergy.com l infoDitekenergy.com MADEIN�AMFRICA �� cO 17 ARRA RAA. and IAA LL-irp Sdw P,*,,f Complioid I— itek ENERGY Building Solar I Powenng The Future High -efficiency monocrystalline silicon PERC cells r^a J Certified PID -free above and beyond the industry standard WII quality check of every module 1J along the production line Itek SE 'your { odk JIB. Impact -resistant, anti -glare solar glass CRiI 25 -year power output warranty Oc7 10 -year workmanship warranty Connectwith us: www.itekenergy.com l infoDitekenergy.com MADEIN�AMFRICA �� cO 17 ARRA RAA. and IAA LL-irp Sdw P,*,,f Complioid I— itek ENERGY Building Solar I Powenng The Future Sinned Energy TodV Inca SOLAR Itek SE 'your { odk JIB. 1001 Cooper Point Rd SW, Suite 140-290 Olympia, WA 98502 Phone 888-405-8689 Fax 855-350-9430 ' support@smartenergytoday net CRRT9pe •60ljgl-eaiciancY morwcryztd— p�t,ye Geis REVISIONS • 6 10 cell matrix Selr(�Ir, • UBro clear one+e8eciwa Ireotment DESCRIPTION DATE REV • tempered, w"h low Iron content INIt IAL 03-15-2018 00 • Anhgiwe Pnsmallc wb—tace bxtwe "� +yGx+'sR, l4r•,e'}¢;R'W:y=,' bC1>•IRet • MVlti hyped • Engineered adnesan for r.�mimum weather pofMpn Cie 1001 mm x 1675mm x SOmm inn. • HxprntTon4,M conosiptxesnlonl onodeed oh,mtnom 3WQN 43 - - lbs Signature with Seal • CarpahDie .11, sfandwd rgcl ng, accommodalmg both top downAv ciamps"ndbottpnflanpemovntkg Coble • 47' 90°C 12AWGPV Juriollori Ria •3byP %diodes 1000 VDC MCd connectors OproRad TwtipRroMe -AO +90°C G --bp • CW eo lo, Wiey 9ectroncs WEEB^ gr dfid g ckps a IOVD vDC • tight.—NJ got i"' locgiions per modWe fw Delon ood put 170M Up to 113Ibitn' redocodg ,dwre length MosOixea load IIILnml - 551 eg/msl5mo Po) _ - ' ,, v ^.:; s; `s�P, „ •,, r<" h• -i i °"1°'.,.n :. .:,,, Ala*_~Load_ 1131Ds/8' I5A PROJECT NAME 8 ADDRESS Muting UL17o3 _11iii—c~ _ ISA fle Rally TWr2 PDPwe 500• hoes ___ -__ - •• �. .• ';'i .: „�k; :'a' ARRA. RIIA. ,,dTMCwrybit _____ flanRglDpRIORIR Cel Trilpeiblae pl0(,•p [• I• a ", ry e: Wil or P. TOelpalplue CoelRClnrlr V)Moailiaigw.�-P-••IMW -.. r.. ,0;. .. �. or 280 285 290 29s 300 Tetipnnlin C.0, a 1, •. Z xaea —valRlle-V.•M 323 32,1 326 328 329 TesspwaARe CaMhi�d of V+• - ti^ - �Jn O LO Maan�e Poero.iwe-Iw•W 86 87 88- 89 - 9D - -397 Z Q Q LO i CVes�V^IIapR-Vo;M-- 39.2 393 395 398 8lxtltfhxYClww!-I.yc1 93 94 9.5 96 97 M9dle VMe Y 16.70% 1699% 1729%. 1759% 1789% 11 O c6 t�J d alo 5mm fD H z �oiry 13 11 m ®u = Q Z Z U')3 0 ® neem; N �Tl mm f` mm �5 nl ® 2 rd. rcticn 0o. - �'zfvi t mm li 9=m1 SHEET NAME • -••m EQUIPMENT sin nq.ncem�n ----Iznlm I6; 9 mr. SPECIFICATION h69..,, SHEET SIZE ANSI B , 11" X 17" SHEET NUMBER PV -6 0,`4 APsystems ALTE NERGY POWER Leading the Industry 1n Solar Microinverter Technology DIMENSIONS Our flagship product, the APsystems YCSODA Is a grid -tied _ - G� N microinverter with intelligent networking and monitoring systems to ensure maximum efficiency. Highly dependable =3 b and cost effective, the YC500A handles up to 31OW ss ns�m> modules with negligible clipping, delivering 250W AC per NEI .atasheet module with dual MPPT. Half the inverters and half the installation means real cost savings for residential and commercial customers. Srtad Energy Today Inc x' SOLAR 1001 CooperPoint Rd SW, Suite 140-290 - • , a Microinverter APsystems .atasheet Olympia, WA 98502 Phone 888-4058689 Fax 855-350-9430 support® smartenerggloday net INPUT DATA (DC) i REVISIONS Recommended PV Module Power Range (STC) 180-31OW OE REV MPPT Voltage Range 22-45V wiri IN IT AL ts-zale w Maximum Input Voltage 55V �,'DATE Maximum Input Current 12A X 2 OUTPUT DATA (AC) Signature mth Seal Rated Output Power SCOW Maximum Output Current 208A a 240V 24A 6`208V Nominal Output Voltage/Range - 240V 240V/211V-264V- Nominal Output Voltage/Range - 208V 208V/183V-229V' Nominal Output Frequency/Range 601-1z/ 59 3-60 SHz' Power Factor 1099 Total Harmonic Distortion <3% PROJECT NAME 8 ADDRESS Maximum Units Per Branch 7 per 20A o 240V 6 Per 20A .6 208V EFFICIENCY Peak Efficiency 955% CEC Weighted Efficiency'- 95% Nominal MPP Tracking Efficiency 995% - U) MECHANICAL DATA Z LIJ Storage Temperature Range -401F to +1851F (-40"C to +85'C) M 0 d r Operating Temperature Range -40'F to +149°F (-40°C to +65"C Q Q r Dimensions (WXHXD) inches 875" x 65" x i 1" U F fn Dimensions (WxHxD) mm 221mm x 167mm x 29mm Q� 0 =)V Weight 5.5 lbs (2.5kg) V d Co O Co Enclosure Rating NEMA 6 cn H00 Cooling Natural Convection - No Fans Q U) 0 Q Uj FEATURES & COMPLIANCE Z � � ZO Communication Power line (PLC) LU X Warranty 10 years standard, extendable to 25 years ' d Emissions & Immunity (EMC) Compliance FCC PART 15, ANSI C63.4 2003, ICES -003 N Safety Class Compliance VL 1741 CSA C22 2. No 1071-01. NEC2074 690.72 r Grid Connection Compliance IEEE 1547 - zub,ea to Jrange wrreou, nnt:ce-n'en;e ens,:e rw. a.e u,ne ane Pro9ra enable per r ustomer antl utll:ty reNnirernents m,s, ect ntnuptlate hcuntl.l www nV�yzte+nz.,,T All settings UL app—,d "CEC .egis[erea �s Altenergy Power Syve Inc- _ SHEET NAME 12115. 11 RI, rs EQUIPMENT SPECIFICATION SHEET SIZE 0.,4APsystems ANSI B ALTENERGY POWER y 11" X 17" SHEET NUMBER PV -71 TOP CLAMP ZZ -111111 BOTTOM CLAMP INTEGRATED ILSCO GROUND LUG - COMPATIBLE WITH #4, #6, #8 & #10 BARE AND STRANDED COPPER WIRE S HOOK BASE PLATE SPIDER -RAX BLACK WIDOW COMPOSITE RACKING SYSTEM DETAIL (NTS) Surat Energy Today lnc." SOLAR 1001 Cooper Point Rd SW, Suite 140-290 Olympia, WA 98502 Phone 888-405-8689 Fax 855-350-9430 support®smartenergytoday net REVISIONS DESCRIPTION DATE REV INITIAL 03.153018 00 I I I I I Signature wdh Seal PROJECT NAME & ADDRESS G LU LU J z� O ri o ��CID �0) =az 1. O E rn N r" SHEET NAME EQUIPMENT SPECIFICATION SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV -8 SnI Energy Today Ino SOLAR 10CMCSA1001 Grou DO Gil'OIIF7 Cooper Point Rtl SW, Suite 140-296 Olympia, WA 98502 Phone 688-4059689 jjj Faz 855-350-9430 • • Certificate of Compliance Certificate: 2763733 Master Contract 262043 support®smartenergiroday net I REVISIONS Project: 2763733 Date Issued: June 4, 2015 ! I DESCRIPTION I CATE REV' Certificate: 2763733 Maser Contract: 262043 ' INITIAL 03-15-20teI W Project: 2763733 Date Issued: June 4, 2015 Devices, Clamping%Retention Devices, and Ground Lugs Issued to: Spider RAX Inc Signature with Seal for use with Flat -Plate Photovoltaic Modules and Panels. 38713 Tierra Subida,200-622 Palmdale, CA 93551 USA Attention: Todd Ayers The products listed below are eligible to bear theCSA Mark shown with adjacent indicators "C"and rUJ r for PROJECT NAME &ADDRESS Canada and US or with adjacent indicator "US"for US only or without either indicator for Canada only. ® rarwrt� Gato>,ja Z LU srgs wy�� j O c� LO C US Issued by: Tatjana Galonja-Stojsavljevic Q Q to U) F W I PRODUCTS CLASS 531302 -POWER SUPPLIF.'S- PHOTOVOLTAI('S-- PV Racking `Qrt v a t�) cep CLASS 5313 82 -POWER SUPPLIES- PHOTOVOLTAICS - PV Racking and clamping H 00 systems -Certified to US Standards = Q LU 'tarantula Z PV Racking Systems, models Red Widow, Black Widow. and Wolf Spider, suitable for use with flat LLIL0 approved -plate photovoltaic modules with maximum size of 1.96 meters by 0.98 meters and a minimum = frame height of 35 mm and a maximum frame height ol'40mm and a series fuse rating of 20 A. d CM Notes. The products are approved as a component only and subject to final approval by authorities having jurisdiction. APPLICABLE REOUIREMENTS OR .AL -001-2012 - Photovoltaic Module and Panel Racking Systems. j SHEET NAME UL Subject 2703 (Issue Number 2) - Outline of Investigation fur Mounting Systems. Mounting EQUIPMENT SPECIFICATION SHEET SIZE ANSI B ov 507 ice. 2a2 05 _2 DQD 507 Rn :01:0522 Payc 2 n X 17n _........ ... ...... _.__....._u ___......__. SHEET NUMBER PV -91