Loading...
HomeMy WebLinkAbout1039 W 7th St - BuildingELECTRICAL PERMIT , CITY OF PORT ANGELES 360-417-4735 Application Number . . . . . 11-00001180 Date 10/20/11 INSPECTOR: Application pin number . . . 670320 REPORT SALES TAX Property Address . . . . . . 1039 W 7TH ST on your, excise tax form ASSESSOR PARCEL NUMBER: 06 -30 -00 -0 -1 -5654 -0000 - to the City of Port Angeles Application typedescription ELECTRICAL ONLY �i �'1 1 Subdivision Name . . . . . . (Location Code 0502) Property Use . . . . . . . . Property Zoning . . . . . . . RS7 RESDNTL SINGLE FAMILY Application valuation . . . . 0 Application desc Sub panel and 4 circuits ---------------------------------------------------------------------------- Owner Contractor ------------------------ BRAD M / CONNIE ALWARD ------------------------ BOTERO & SON ELECTRICAL 1039 W 7TH ST 940 TAMARACK WAY PORT ANGELES WA 983635705 PORI' ANGELES WA 98362 (360) 452-4766 ---------------------------------------------------------------------------- Permit . . . . . . ELECTRICAL ALTER RESIDENTIAL Additional desc . . Permit pin number . 194910 Permit Fee . . . . 130.30 Plan Check Fee .00 Issue Date . . . . 10/20/11 Valuation . . . . 0 Expiration Date . . 4/17/12 Qty Unit Charge Per Extension 4.00 2.6000 ECH EL -BRANCH CIRCUIT W/FEEDER 10.40 1.00 119.9000 ECH EL -0-200 SRV FEEDER 119.90 ---------------------------------------------------------------------------- Fee summary ' Charged Paid Credited Due Permit Fee Total 130.30 130.30 .00 .00 Plan Check Total .00 .00 .00 .00 Grand Total 130.30 130.30 .00 .00 INSPECTION TYPE DATE: RESULTS: INSPECTOR: DITCH SERVICE ROUGH -IN FINAL lG�1 u J Z1 �i �'1 1 COMMENTS: PERMIT WILL EXPIRE SIX (6) MONTI-IS FROM LAST INSPECTION Signature of owner or Electrical Contractor X Date: GAEXCHANGE\131JILDING CITY OF PORT ANGELES PERMIT APPLICATION Building Division/Electrical Inspections 321 East Fifth Street — P.O. Box 1150 / Port Angeles Washington, 98362 Ph: (360) 417-4735 Fax: (360) 417-4711 1 & 2 Single Family Dwelling _ Multi -Family or Commercial* OCT 19 2011 ELECTRICAL INSPECTIONS Commercial Addition / Alteration / Remodel / Repair* * Plan Review May Be Required, Please Complete'Elgctrical Plan Review Information Sheet Job Address: 11_7 s(2/ —� Building Square Footage: Description of above — :�,n �, ��.+ •.� . _j o� Owneormatio /) / Contrac or InfgLwation ; Name: Name:. �- r' Mailing Address: ins Mailin dress:__3u6` r%` City: VA- State: _Zip: �� r3�,���� City: T State: 6F,A Zip: r` Phone: Fax: Phone:I.QI i Fax: 14 License # / Exp. License # I ExP__j� Item Unit Charge Qt Total (Qty�M�ultt�llied by Unit Charqe) Service/Feeder 200 Amp. $119.90 $—� t C_ Service/Feeder 201-400 Amp. $ 145.50 $ Service/Feeder 401-600 Amp $ 204.60 $ Service/Feeder 601-1000 Amp. $ 262.20 $ Service/Feeder over 1000 Amp. $ 372.50 $ Branch Circuit W/ Service Feeder $ 2:60 W $ Branch Circuit W/O Service Feeder $ 73.50 $ Each Additional Branch Circuit $ 2.60 $ Temp, Service/ Feeder 200 Amp. $ 92.70 $ Temp. Service/Feeder 201-400 Amp. $110.30 $ Temp. Service/Feeder 401-600 Amp. $148.70 $ Temp. Service/Feeder 601-1000 Amp . $ 167.90 $ Portal to Portal Hourly $ 95.90 $ Sign/Outline Lighting $ :88.20 $ Signal Circuit/ Limited Energy / First 1500 sf — Commercial $ 95.90 $ Note: $5.00 for each additional,1500 sf Signal Circuit/ Limited Energy -1 & 2 Family Dwelling $ 63.90 $ Signal Circuit/ Limited Energy - Multi -Family Dwelling $ 63.90 $ Manufactured Home Connection $ 119.90 $ Renewable Electrical Energy - 5KVA System or Less $ 102.30 $ Thermostat $ 56.00 $ NEW CONSTRUCTION -ONLY: First'1300 Square Ft. $ 110.30 $ Each Additional'500'Square Ft. or Portion of $ 35.20 $ Each Outbuilding or Detached Garage $ 73.50 $ Each Swimming Pool or Hot Tub $ 110.30 $ $ Total Owner as defined by RCW.19.28.261: (1) Owner will occupy the structure for two years after this electrical permit is finalized. (2) Owner is required to;hire an electrical contractor if above said property is for sale, rent or lease. Permit expires after six months ofiast inspection.' After reading the above statement, I hereby certify that I am the owner of the above named property or a licensed electrical contractor. I am making the electrical installation or alteration in compliance_with the electrical laws, N.E.C., RCW. Chapter 19.28, WAC. Chapter 296-4613, The City of Port Angeles Municipal Code, and Utility Specifications and PAMC 14.05.050 regarding Electrical .Permit Applications. Signature of owner, electrical contractor or electrical administrator: ❑ Cash ❑ Check / I Vredit Card X , r 0[ Dated: ri J C Y T7i% 90,12010 1 DAY )b"06) PREPARED 5/13/10 8 28 05 INSPECTION TICKET PAGE 4 CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 5/13/10 ADDRESS 1039 W 7TH ST SUBDIV TENANT NBR BRAD M / CONNIE ALWARD CONTRACTOR CLAWSON CONSTRUCTION LLC PHONE (360) 457 1473 OWNER BRAD M / CONNIE ALWARD PHONE PARCEL 06 30 00 0 1 5654 0000 APPL NUMBER 09 00000854 RES ADDITION REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS PLEASE CALL DAVE CLAWSON AT 461 9295 OR KEVIN RUSSELL AT 457 8247 ABOUT 30 MINUTES BEFORE YOU GET THERE SO ONE OF THEM CAN MEET YOU THERE AND LET YOU IN March 10 2010 4 55 01 PM jlierly finish landings at rear doors and stairs/address numbers required on front of house/finish porch surface in front JLL ok to occupy temp co issued on this date jll BL99 02 5/13/10 L BLDG FINAL TIME 01 00 ` May 12 2010 4 28 05 PM 1pangrle l \ \ DAVE 461 9295 BUILDING FINAL AFTERNOON COMMENTS AND NOTES J L' POR)TIANGELES WASHINGTON, U S A COMMUNITY & ECONOMIC DEVELOPMENT DEPARTMENT DATE March 11, 2010 T O Brad M / Connie Alward 1039 W 7th street FROM Jim Lierly Community & Economic Development Department SUBJECT Temporary Certificate of Occupancy The Department of Community & Economic Development Is granting a temporary certificate of occupancy for 30 days from the date of this letter The areas that are permitted to be occupied are as follows 1 Address signage per code shall be applied to front of structure 2 -Landings per code shall be required on north side of structure 3 -Complete weather proofing for walking surface, under covered porch, south side 4 -Please complete the above mentioned items and recall for inspection Maintain continued construction in a manor that does not endanger the public by restricting area s that are still under construction Maintain exists and fire protection systems from damage or obstruction due to construction that is on goin Atany time this Temporary CO may be revoked for any reason deem d by the Building Official All adopted codes apply If yo4ee any furt er questions please contact the Department of Community pment if yo have any questions 417-4815 Jim LierlyBuilding Ins ` 360-417-4815 PREPARED 3/10/10 9 21 38 INSPECTION TICKET PAGE 4 CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 3/10/10 ADDRESS 1039 W 7TH ST SUBDIV TENANT NBR BRAD M / CONNIE ALWARD CONTRACTOR CLAWSON CONSTRUCTION LLC PHONE (360) 457 1473 OWNER BRAD M / CONNIE ALWARD PHONE PARCEL 06 30 00 0 1 5654 0000 APPL NUMBER 09 00000854 RES ADDITION PERMIT SPR 00 BUILDING PERMIT RESIDENTIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS BL2 01 9/22/09 JLL BLDG FOUNDATION STEM WALL TIME O1 00 9/22/09 AP September 22 2009 8 38 49 AM 1pangrle DAVE 461 9295 STEMWALL AFTERNOON September 22 2009 4 15 24 PM jlierly BL9 01 10/21/09 JLL BLDG SHEARWALL TIME 01 00 10/21/09 AP October 21 2009 8 02 36 AM 1pangrle DAVE 461 9295 PLYWOOD EXTERIOR NAILING AFTERNOON October 21 2009 3 48 03 PM jlierly DSD O1 10/23/09 JLL BLDG DOWN SPOUT DRAINS 10/23/09 AP October 23 2009 8 20 16 AM 1pangrle DAVE 461 9295 DOWNSPOUT DRAINS October 23 2009 4 05 24 PM jlierly water line and drywell inspected and approved on this date/jll BAIR O1 12/04/09 JLL BLDG AIR SEAL TIME O1 00 12/08/09 AP December 4 2009 8 23 50 AM 1pangrle DAVE 461 9295 AIRSEAL AFTERNOON December 8 2009 3 40 56 PM jlierly BL3 01 12/04/09 JLL BLDG FRAMING TIME 01 00 12/08/09 AP December 4 2009 8 23 28 AM 1pangrle DAVE 461 9295 FRAMING AFTERNOON December 8 2009 3 40 56 PM jlierly BLI 01 12/11/09 JLL BLDG INSULATION TIME 01 00 12/11/09 DA December 11 2009 9 00 26 AM 1pangrle DAVE 461 9295 INSULATION AFTERNOON December 11 2009 4 09 24 PM jlierly Upper two levels ok basement needs to have walls or ceiling completed depending on the method used for heating ok to install GWB in ground level and upper story of building complete basement and recall/jll BL99 01 3/10/10 T c BLDG FINAL TIME O1 00 March 9 2010 2 11 20 PM 1pangrle VZ7KEVIN 457 8247 BLDG FINAL HOUSE ADDITION & REMODEL CONTINUED ONTO NEXT PAGE kTeA-f e- Of ly 1; PREPARED 3/10/10 9 21 38 INSPECTION TICKET PAGE 5 CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 3/10/10 ADDRESS 1039 W 7TH ST SUBDIV TENANT NBR BRAD M / CONNIE ALWARD CONTRACTOR CLAWSON CONSTRUCTION LLC PHONE (360) 457 1473 OWNER BRAD M / CONNIE ALWARD PHONE PARCEL 06 30 00 0 1 5654 0000 APPL NUMBER 09 00000854 RES ADDITION REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS PLEASE CALL DAVE CLAWSON AT 461 9295 OR KEVIN RUSSELL AT 457 8247 ABOUT 30 MINUTES BEFORE YOU GET THERE SO ONE OF THEM CAN MEET YOU THERE AND LET YOU IN PERMIT ME 00 MECHANICAL PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ME99 01 3/10/10 J MECHANICAL FINAL TIME O1 00 March 9 2010 2 12 01 PM 1pangrle KEVIN 457 8247 MECHANICAL FINAL HOUSE ADDITION & REMODEL PLEASE CALL DAVE CLAWSON AT 461 9295 OR KEVIN RUSSELL AT 457 8247 ABOUT 30 MINUTES BEFORE YOU GET THERE SO ONE OF THEM CAN MEET YOU THERE AND LET YOU IN PERMIT PL 00 PLUMBING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS PL2 01 10/29/09 JLL PLUMBING ROUGH IN 10/29/09 AP October 28 2009 2 04 48 PM 1pangrle JOEL 461 1863 ROUGH IN PLUMBING October 29 2009 4 22 32 PM jlierly PL99 01 3/10/10 PLUMBING FINAL TIME O1 00 March 9 2010 2 12 24 PM 1pangrle KEVIN 457 8247 PLUMBING FINAL HOUSE ADDITION & REMODEL PLEASE CALL DAVE CLAWSON AT 461 9295 OR KEVIN RUSSELL AT 457 8247 ABOUT 30 MINUTES BEFORE YOU GET THERE SO ONE OF THEM CAN MEET YOU THERE AND LET YOU IN COMMENTS AND NOTES PREPARED 3/10/10 9 21 38 INSPECTION TICKET PAGE 9 CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 3/10/10 ADDRESS 1039 W 7TH ST SUBDIV TENANT NBR BRAD M / CONNIE ALWARD CONTRACTOR CLAWSON CONSTRUCTION LLC PHONE (360) 457 1473 OWNER BRAD M / CONNIE ALWARD PHONE PARCEL 06 30 00 0 1 5654 0000 APPL NUMBER 10 00000164 RES ACCESSORY BUILDING PERMIT BPR 00 BUILDING PERMIT RESIDENTIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS BL99 01 3/10/10 BLDG FINAL TIME O 00 March 9 2010 2 06 144 PM 1pangrle KEVIN 457 8247 BLDG FINAL BOAT CARPORT PLEASE CALL DAVE CLAWSON AT 461 9295 OR KEVIN RUSSELL AT 457 8247 ABOUT 30 MINUTES BEFORE YOU GET THERE SO ONE OF THEM CAN MEET YOU THERE AND LET YOU IN COMMENTS AND NOTES lb� " z)te-tvlv. .` CITY OF PORT ANGELES DEPARTMENT OF COMMUNITY & ECONOMIC DEVELOPMENT BUILDING DIVISION W �— 321 EAST 5TH STREET PORT ANGELES, WA 98362 Application Number Application pin number Property Address ASSESSOR PARCEL NUMBER Tenant nbr name Application type description Subdivision Name Property Use Property Zoning Application valuation Application desc 312 SQ FT BOAT CARPORT 10 00000164 Date 3/09/10 996120 1039 W 7TH ST 06 30 00 0 1 5654 0000 BRAD M / CONNIE ALWARD RES A�H3�3ALd Aazl,sory BuI:Mding RS7 RESDNTL SINGLE FAMILY 3744 Owner Contractor BRAD M / CONNIE ALWARD CLAWSON CONSTRUCTION LLC 1039 W 7TH ST P O BOX 2683 Fee summary PORT ANGELES WA 983635705 PORT ANGELES WA 98362 (360) 457 1473 Due Structure Information 000 000 312 SF BOAT CARPORT 75 Other struct info HARD SURFACE AREA 75 Permit BUILDING PERMIT RESIDENTIAL Plan Check Total Additional desc 312 SF BOAT CARPORT 44 Permit pin number 161109 44 00 Permit Fee 123 75 Plan Check Fee 80 44 Issue Date 3/09/10 Valuation 3744 Expiration Date 9/05/10 00 Grand Total Qty Unit Charge Per 69 Extension BASE FEE 00 95 75 2 00 14 0000 THOU BL -2001 25K (14 PER K) 28 00 Special Notes and Comments The Fire Department has reviewed the project application and has no comments February 23 2010 11 03 20 AM sroberds The proposal will result in a detached garage in the RS 7 zone for total lot coverage of 18W and site coverage of 19W No land use issues anticipated February 23 2010 10 41 59 AM Brian 417 4708 OK Public Works Utility Engineering has no requirements for this plan review Other Fees STATE SURCHARGE 4 50 Fee summary Charged Paid Credited Due Permit Fee Total 123 75 123 75 00 00 Plan Check Total 80 44 80 44 00 00 Other Fee Total 4 50 4 50 00 00 Grand Total 208 69 208 69 00 00 Separate Permits are required for electrical work, SEPA, Shoreline, ESA, utilities, private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned for a period of 180 days after the work has commenced, or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the Performa o onstruction. Date Print Name T:FormsBuilding Division/Building Pennit Signature of Contractor or Authorized Agent Signature of Owner (if owner is builder) BUILDING PERMIT INSPECTION RECORD PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS - Building Inspections 417-4815 Electrical Inspections 417-4735 Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886 IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE. Inspection Type FOUNDATION Footings Stemwall Foundation Drainage / Downspouts Piers Post Holes (Pole Bldgs.) PLUMBING Under Floor/ Slab Rough -In Water Line (Meter to Bldg) Gas Line Back Flow / Water AIR SEAL. Walls Ceiling FRAMING Joists / Girders / Under Floor Shear Wall / Hold Downs Walls / Roof / Ceiling Drywall (Interior Braced Panel Only) T -Bar INSULATION Slab Wall / Floor / Ceiling MECHANICAL. Heat Pump / Furnace / FAU / Ducts Rough -In Gas Line Wood Stove / Pellet / Chimney Commercial Hood / Ducts MANUFACTURED HOMES Footing / Slab Blocking & Hold Downs Skirting PLANNING DEPT Separate Permit #s Parking / Lighting Landscaping Date I Accepted By Comments I I I IFINAL Date Accepted by I I !I I I I I I I IFINAL Date Accepted by SEPA. ESA. SHORELINE. FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/ USE Inspection Type Date Accepted By Electrical 417-4735 Construction R.W PW / Engineering 417-4831 Fire 417-4653 Planning 417-4750 Building 417-4815 10 -SL — T:Forms/Building Division/Building Permit OFPORT qELECTRICAL INSPECTION WIRING REPORT RKS & 417-4735 � DATE PERMIT k ..> 09 -c`e5-g OWNER/CONTRACTOR Vag-�R�- �o ►J ADDRESS / 63 APPROVED ❑ DITCH ❑ ROUGH IN/COVER ❑ SERVICE ❑ FINAL INSPECTOR 'V� NOT APPROVED CORRECTIONS NEEDED: /� '�IrL OTiIC G� I) IQ -;::-I ti-) 115 )6c- 21C) -psccla5 -T-c) r�A rj4 c mi-- Jzvj::Z)L) LKc--> NOTIFY INSPECTOR WHEN CORRECTIONS ARE COMPLETED WITHIN 15 DAYS — DO NOT REMOVE — pCJH1 +k, BUILDING PERMIT APPLICATION Print in ink CITY OF PORT ANGELES Attn Building Permit Technician '321 E Fifth St. Port Angeles WA 98362 (360) 417-4815 fax (360) 417 -4711 Applicant Property Owner gll-)96 loAj,)It5� Property Owner's Address /0-3 9r- c, -7—^ J 7 Contractor e&,o4,-je)A) Z?o evi c -_*11'0,.J Contractor's Address 16� License # q&3 125- 'Expires 12—Ilo For City Use On Date Received -I Permit # I (N,— I. Lf Date Approved 0 Phone Phone 'Phone 3100 '/'S7 P, 2- el 7 E-mail PROJECT ADDRESS 103 9 7 s -7 Parcel Number 0(P-30 00 olf Lot JI t 2 Zoning Project Type & Brief Description. Residential Ej Multi -family o Commercial o4ndustrial Check all that apply o New Construction Addition boot CAlro0t_ 12- x 2-4 enc- losek or. I -1A rvp- 5 1 Ap-s o Remodel • Repair • Demolition • Re -roof zi House o garage n other r- tear off & re -roof o Jay over one layer • Heat.Systern o Heat pump o wood -burning stove o gas fireplace Ei pellet stove o other • Other Floor Areas Basement 15` Floor 2nd Floor 3`d Floor Garage Carport Covered Porch Deck Shed Other Existing (sq. ft.) 2-)-D Z .i MIR liq Proposed (sq. ft.) 0 @$ it M-0 -31Z I Z.. 00 per sq ft. = $ 37,1(1 -- St= + S go J S f TOTAL VALUATION $ Total footprint of structures sq ft. T Lot size sq ft. = Lot coverage % Site, Coverage = the amount of impervious surface on a parcel including: structures paved driveways sidewalks patios, and other impervious surfaces (see PAMC 17 94 135 for exemptions) Site coverage /112- % 0.3Z ­ Max. height of proposed structures 12 Occupancy group # of bedrooms Will a lawn sprinkler system be installed? Occupant load # of full baths Will a fire sprinkler system be installed? Construction type # of half baths / have read and completed this application ind know it to be true and correct. / am authorized to apply for this permit and anderstand that it ; r w responsibility to determine what ptiri-lits are required, and to obtain permits prior to w�vkinq on projects Date %14146. Prnt Name Signature F fu,ms/Buildinq Division/Buildmg permit app' -,P',ion -_-j A02 -f Clallam County Assessor & Treasurer - Property Details - 57126 BRAD MICONNIE AL Page 1 of 4 Clallam County Assessor & Treasurer Property Search Results > 57126 BRAD M/CONNIE ALWARD for Year 2010 - 2011 Property Account Property ID- 57126 Geographic ID- 0630000156540000 Type Real Legal Description LOTS 11&12 BL 156 Agent Code. Tax Area. 0010 PA 121 PORT ST CNTY H2 L Land Use Code Open Space- N DFL Historic Property, N Remodel Property* Multi -Family Redevelopment: N Location Address: 1039 W SEVENTH ST Mapsco PORT ANGELES WA 98362 Neighborhood: Cycle 5 Res Map ID - Neighborhood CD- 10955130 Owner Name BRAD M/CONNIE ALWARD Mailing Address: 1039 W 7TH ST PORT ANGELES WA 98363-5705 1 Taxes and Assessments Due Property Tax Information as of 02/19/2010 Amount Due if Paid on. M Owner ID- % Ownership Exemptions: ! First Half Statement Base Year ID Taxing Jurisdiction Due 2010 40134 ST SCH STATE SCHOOL $202.41 2010 40134 CC -GEN COUNTY $10771 2010 40134 PORT PORT $1514 2010 40134 PORT ANG PORT ANGELES $249 39 2010 40134 SD #121 SCHOOL DISTRICT #121 $262.18 2010 40134 _ NTH OLY LIB NORTH OLYMPIC LIBRARY $31 30 2010 40134 HOSP #2 HOSPITAL #2 $4419 2010 40134 WSMET PK DIST WILLIAM SHORE MET PARK DIST $1406 2010 40134 CITY STORMWATER CITY STORMWATER $3600 2010 40134 WEED—CONTROL WEED CONTROL $082 2010 40134 TOTAL. $963.20 2009 571262008 ST SCH STATE SCHOOL $229.20 2009 571262008 CC -GEN COUNTY $116'00 2009 5712620_08 PORT PORT $1643 2009 571262008 PORT ANG PORT ANGELES $25443 2009 571262008 SD #121 SCHOOL DISTRICT #121 $28344 2009 571262008 NTH OLY LIB NORTH OLYMPIC LIBRARY $3370 2009 571262008 HOSP #2 HOSPITAL #2 _ $4757 2009 571262008 CITY STORMWATER CITY STORMWATER $3600 11 N N r N 10852 100 0000000000% Second Half Base Base Arr Due Penalty Interest Paid Du $20241 $000 $000 $000 $_1 _$10772 $000 $000 $000 $: $1514 $000 $0 00 $000 $24941 $0 00 $000 $000 ~$� $262.17 $000 $000 $000 $', $31_30 $000 $000 $000 $4419 $000 $000 $000 $1406 $000 $000 $000 $3600 $000 $000 $000 $081 $000 $000 $000 $963.21 $0.00 $0.00 $0.00_ $16 $229.20 $000 $0 00 $45840 $11599 $000 $000 $231 99 $1643 $000 $000 $32.86 $25442 $000 $000 $50885 $28345 $000 $000 $56689 $3371 $000 $000 $6741 $47.57 $000 $0 00 $9514 $36 00 $000 $000 $72.00 http.//vpn.ciallam.net:8084/propertyaccess/Property.aspx?cid=0&year=2010&prop_id=57 2/19/2010 FA 4-. us W N9 h! `jtr�� r f -#VV 1%C Pf%nlr Apitt9:LES -- Cansruction Plans The Issuance of this permit based upon thw;e plans, specifi- cations and other data shall not prevent the building official from thereafter requiring the correction if errors in said pla^s specifications and other data, or from preventing building operations being carried on thi -eunder when in violation of all codes and ordinances o this jurisdiction. prove! Date' ° By NMI (OD -Ft 5? rw�1 d Q rLN, Qd - Q9 �t� ��- � �1 4N`i gil N z a �A�E ''r vs�► kil VIS./ F tl I� iIk 11�� llb %Il Cars,Trucks,RY's,Farm Equipment,Carports,Garages;Utility Buildings,Etc, Vv% COVER IT ALL We understand that buying a steel building is a signfcant investmentfor your Family or business We have high quality ,products at eordable`prices andwe take_pride in our customer service. With ourprofessionaf instaClation crews as well as highly skiffedfabrication teams, we are a company that hasproven time again to get the job done with customer sari faction. Coast to Coast CaTorts Inc. is your best choice for quality steel buildings CALL YOUR ' CUSTOM '/COLORS T k � L AVAILAELE 225251-40 127211.27 South 3702 Industrial Park, 340 Centennial Dr, 210 E. Locust,st, Knoxville,AR, 72845 Amarillo,TX,79118 Gallup,NM, 87305 Heyburn,ID,83336 Stanfield;OR, 97875 Financing Financing A vai/able ®� ®' ® Available Idaho, Oregon Wyandng, Montana, Utha REGULARSTYLE ,.,TANA,,D FEATURES 41 Between Each Bow 12 x 21 $795.00 18 x 2 1* - $995.00 12 x 26 $995.00. 18 x 26. $1,245.00 12 x 31 $1,245.00 18 x 31 $1,555.00 .12 x 36 $11'555.00 18 x 36 $1,895.00 12 x 41, $1,695.00 18. x 41 $2*695.00 I ' 12 x 21 $995.00 18 x 21 12 x 26 v $1,195.00 18 x 26 12 x 31 $1,345.00 18 x 31 12 x 36 $1,655.00 18 x 36 12 x 41 $2,095.00 18 x 41 Has Horizontal goof AS, LOW AS 6:Bowg an ' d welded center $19195.00 braces for strength there x 21 20 will:be a brace on every leg s -00 for added support. .795 x 31 $1,895.00 STANDARD 14 GAUGE, S' LEGS 30 x 31 X 6 149a� 20 33==-J' S3MX.3r.=XL Prices are for top with open sides only CAN NOW an wavas POA ONLY, x 36 , 14 Gauge 20 x 21 $19195.00 22- x 21 20 k 26 $1,495-00 22 x 26 20 x 31 $1,895.00 22 x 31 20 x 36 $2,195.00 22 x 36 20. x 41 $2,495.00 22 x 41 NOTE. Vertical Buildings are 1 shorter than horizontal. 12 x 21 12 Gauge $1,195.00 20 x 21 $1,295.00 $1,395.00 20 x 26 $1,695.00 $1,695.00 20 x 31 $2,095.00 $2,095.00 20 x 36 $2,395.00 $2,395.00 20 x 41 $2,695.00 NOTE. Vertical Buildings are 1 shorter than horizontal. 12 x 21 $895.00 18 x 21 $1,095.00 12 x 26 $1,120.00 18 x 26 $1,370.00 12 x 31 $1,395.00 18 x 31 $1,705.00 12 x 36 $1,730.00 18 x 36 $2,070.00 12 x 41 $1,895.00 18 x 41 $2,295.00 $1,295*.001 2.4 x 21' - $1,495.00 $1,595.00 24 x. 26 $1,8.95400. $1,995.00 24 x 31 $2,395.00 $2,41:95M -24 x 36 $2,695.00 9,695.00. $2,695'.00 24 x 41 $3,095.00 22 x 21. $1,495.00 24 x 21 $1,795.00 22 x 26 $1,795.00 24 x 26 $2,195.00 22 x 31 $2,295.00- 24 x 31 $2,695.00 22 x 36 $2,895;00 24 x 36 $2,995.00 22 x 41 $3,095.00 24 x 41 $3,495.00 STANARD FEATURE 4 -FRAME STYLE r6 BowsDand welded cenSter braces for strength there willbe a brace on every leg AS LOW AS for added support. s895 -00 - STANDARD 14 GAUGE, 6' LEGS _/ Prices are for top with open sides only 30 Z 3 1 1614 ga� mma-r =3 ,;y wl"Zo3w CAN NOW CC 3roxL We Offer 3 Styles *A -Frame Longways *A -Frame Vertical Roof Only '*A-Frarne Vertical Entire Bldg. 22 14 Gauge 20 x 21 $1,295.00 20 x 26 $1,620.00 20 x 31 $2,045.00 20 x 36 $2,370.00 26 x 41 $2,695.00 30 Z 3 1 1614 ga� mma-r =3 ,;y wl"Zo3w CAN NOW CC 3roxL We Offer 3 Styles *A -Frame Longways *A -Frame Vertical Roof Only '*A-Frarne Vertical Entire Bldg. 22 x 21 $1,39100' 24 x 21' 22 x 26 $1,720.00 24 x 26 22 x 31 $2;145.00 2,4 x 31 22 x 36 $2,670.00 24 x 36 22 x 41 $2,895.00 24 x 41 $1,595M $2,020.00 $2,545.00 $2,870.00 $3,295.00 $1,595.00 24 x 21 $1,895.00 $1,920.00 24 x 26 $2,320.00 $2,4145.00 24_x 31 $2,8_45__00_ 12 Gauge 24 x 36 $3,170.001. 12 x- 21- $1,095.00 18 x 21 $1,295.00 20 x 21 $1,39500 22 x 21 12 x 26 $1,320.00 - 18 x 26 $1,520.00 20 x 26 $1,820.00 22 x 26 12 x 31 $1495.00 18 x 31 $1,845.00 20 x 31 $2,245.00 2.2 x 3_1_ 13 x 36 $1,830.00 1.8 x 36 $2,270.00 20 x 36 $2,57000 22 x 36 12 x 41 $2,295.00 18 x 41 $2,595 00 20 x 41 $2,8955 00 22 x 41 $1,595M $2,020.00 $2,545.00 $2,870.00 $3,295.00 $1,595.00 24 x 21 $1,895.00 $1,920.00 24 x 26 $2,320.00 $2,4145.00 24_x 31 $2,8_45__00_ $3,070.00 - 24 x 36 $3,170.001. .24 x 41 PREPARED 12/11/09 9 01 46 INSPECTION TICKET PAGE CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE ADDRESS 1039 W 7TH ST SUBDIV TENANT NBR BRAD M / CONNIE ALWARD CONTRACTOR CLAWSON CONSTRUCTION LLC PHONE (360) 457 1473 OWNER BRAD M / CONNIE ALWARD PHONE PARCEL 06 30 00 0 1 5654 0000 APPL NUMBER 09 00000854 RES ADDITION PERMIT BPR 00 BUILDING PERMIT RESIDENTIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS BL2 01 9/22/09 JLL BLDG FOUNDATION STEM WALL TIME O1 00 9/22/09 AP September 22 2009 8 38 49 AM 1pangrle DAVE 461 9295 STEMWALL AFTERNOON September 22 2009 4 15 24 PM jlierly BL9 01 10/21/09 JLL BLDG SHEARWALL TIME O1 00 10/21/09 AP October 21 2009 8 02 36 AM 1pangrle DAVE 461 9295 PLYWOOD EXTERIOR NAILING AFTERNOON October 21 2009 3 48 03 PM jlierly DSD 01 10/23/09 JLL BLDG DOWN SPOUT DRAINS 10/23/09 AP October 23 2009 8 20 16 AM 1pangrle DAVE 461 9295 DOWNSPOUT DRAINS October 23 2009 4 05 24 PM jlierly water line and drywell inspected and approved on this date/jll BAIR O1 12/04/09 JLL BLDG AIR SEAL TIME O1 00 12/08/09 AP December 4 2009 8 23 50 AM 1pangrle DAVE 461 9295 AIRSEAL AFTERNOON December 8 2009 3 40 56 PM jlierly BL3 01 12/04/09 JLL BLDG FRAMING TIME O1 00 12/08/09 AP December 4 2009 8 23 28 AM 1pangrle DAVE 461 9295 FRAMING AFTERNOON � � December 8 2009 3 40 56 PM jlierly BLI O1 12/11/09 T BLDG INSULATION TIME Ol 00 � December 11 2009 9 00 28 AM 1pangrle 4--l' QQJ DAVE 461 9295 INSULATION AFTERNOON C31MTiZATS AND AOTES wp" 1 12/11/09 PREPARED 12/04/09 8 24 48 INSPECTION TICKET PAGE 1 CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 12/04/09 ADDRESS 1039 W 7TH ST SUBDIV TENANT NBR BRAD M / CONNIE ALWARD CONTRACTOR CLAWSON CONSTRUCTION LLC PHONE (360) 457 1473 OWNER BRAD M / CONNIE ALWARD PHONE PARCEL 06 30 00 0 1 5654 0000 APPL NUMBER 09 00000854 RES ADDITION PERMIT BPR 00 BUILDING PERMIT RESIDENTIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS BL2 01 9/22/09 JLL BLDG FOUNDATION STEM WALL TIME O1 00 9/22/09 AP September 22 2009 8 38 49 AM 1pangrle DAVE 461 9295 STEMWALL AFTERNOON September 22 2009 4 15 24 PM jlierly BL9 01 10/21/09 JLL BLDG SHEARWALL TIME O1 00 10/21/09 AP October 21 2009 8 02 36 AM 1pangrle DAVE 461 9295 PLYWOOD EXTERIOR NAILING AFTERNOON October 21 2009 3 48 03 PM jlierly DSD O1 10/23/09 JLL BLDG DOWN SPOUT DRAINS 10/23/09 AP October 23 2009 8 20 16 AM 1pangrle DAVE 461 9295 DOWNSPOUT DRAINS October 23 2009 4 05 24 PM jlierly water line and drywell inspected and approved on this date/jll BAIR O1 12/04/09 JL BLDG AIR SEAL TIME 01 00 December 4 2009 8 23 50 AM 1pangrle DAVE 461 9295 AIRSEAL AFTERNOON BL3 01 12/04/09 JL BLDG FRAMING TIME 01 00 December 4 2009 8 23 28 AM 1pangrle DAVE 461 9295 FRAMING AFTERNOON COMMENTS AND NOTES PREPARED 10/29/09 8 18 40 INSPECTION TICKET PAGE 2 CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 10/29/09 ADDRESS 1039 W 7TH ST SUBDIV TENANT NBR BRAD M / CONNIE ALWARD CONTRACTOR CLAWSON CONSTRUCTION LLC PHONE (360) 457 1473 OWNER BRAD M / CONNIE ALWARD PHONE PARCEL 06 30 00 0 1 5654 0000 APPL NUMBER 09 00000854 RES ADDITION PERMIT PL 00 PLUMBING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS PL2 01 10/29/09 JLL PLUMBING ROUGH IN 1. October 28 2009 2 04 48 PM 1pangrle JOEL 461 1863 ROUGH IN PLUMBING COMMENTS AND NOTES ELECTRICAL PERMIT CITY OF PORT ANGELES 360-417-4735 Application Number 09 00001126 Date 10/29/09 Application pin number 329630 DITCH Property Address 1039 W 7TH ST ASSESSOR PARCEL NUMBER 06 30 00 0 1 5654 0000 Application type description ELECTRICAL ONLY Subdivision Name FINAL Property Use Property Zoning RS7 RESDNTL SINGLE FAMILY Application valuation 0 Application desc New home T stat Owner Contractor ALWARD BRAD M/CONNIE DAVE S HTG & COOLING SRVC INC 1039 W 7TH ST PO BOX 413 PORT ANGELES WA 983635705 PORT ANGELES WA 98362 (360) 452 0939 Permit ELECTRICAL NEW RESIDENTIAL Additional desc Permit pin number 155838 Permit Fee 43 75 Plan Check Fee 00 Issue Date 10/29/09 Valuation 0 Expiration Date 4/27/10 Qty Unit Charge Per Extension 1 00 43 7500 ECH EL LVT THERMOSTAT 43 75 Fee summary Charged Paid Credited Due Permit Fee Total 43 75 43 75 00 00 Plan Check Total 00 00 00 00 Grand Total 43 75 43 75 00 00 INSPECTION TYPE I DATE RESULTS INSPECTOR. DITCH SERVICE ROUGH IN A FINAL COMMENTS Signature of owner or Electrical Contractor X Date Oct 28 09 09 50a Dave s Heating & Cooling 3604520939 p 1 $ 93.75 , RECEIVED $113.75 City of Port Angeles Permit Application Building DivisionlElectrica) Inspections OCT 2 8 2009 %K)Rr2t., 321 East Fifth Street— P.O. Box 115D $ Part Angeles Washington, 98362 ELECTRICAL $205.00 Ph: (360) 417-4735 Fax: QN) 417-4711 l BNSPECTIONSDate: i � (ocl Service/Feeder 601-1000 Amp. $291.25 $ )< 1 & 2 Single Family Dwelling Qi _ Multi -Family or Commercial` Branch Circuit W! Service Feeder Commercial Addition I Alteration /Remodel I Repair' $ Plan Review May Be Required, Please Complete Electrical Plan Review Information Sheet $ 2.00 Job Address: l 0 w4 .+ —71& Each Additional Branch Circuit Building Square Footage: $ Description of above 10 ""'P s s v►, It1'1 St'�t.�.te�"1Oh ✓V.CU Co•.+c ttrflG^{'l h;'� Temp. Service/Feeder 201-400 Amp. A Ownerinfoj(�{ ation l Contractor Information Na— Z - V -CL,& - C� t-.v� a � w, -ci Name: _bckve s f�(ecs +SSS Mailing,Address: 1C:)_3`1 _IfA Mailing,Qddress: 1<'0. City or-{-Nv� State: C,�A Zip 4$3Ca City or* AwjzCa,�state: CuA Zip: 4_7S36_4 Phone. Fax: Phone: �fSS- Fax: 4�` —0939 License #I Exp. License#I Exp. V6_5 j' L'l? (aG Unit Charge QtV Total (ON MUltiolied by Unit Charoe) $ 93.75 $ Service/Feeder 200 Amp. $113.75 $ ServicelFeeder201.400Amp, $160.00 $ Service/Feeder 401-600 Amp. $205.00 $ Service/Feeder 601-1000 Amp. $291.25 $ Service/Feeder over 1000 Amp. $ 2.00 $ Branch Circuit W! Service Feeder $ 57.50 $ Branch Circuit W/O Service Feeder $ 2.00 $ Each Additional Branch Circuit $ 7250 $ Temp. Service/ Feeder 200 Amp. $ 86.25 $ Temp. Service/Feeder 201-400 Amp. $116.25 $ Temp. Service/Feeder401-600 Amp. $13125 $ Temp. ServicelFeeder 601-1000 Amp. $ 75.00 $ Portal to Portal Hourly $ 69.00 $ SignlOutline Lighting $ 75.00 $ Signet CircuiU Limited Energy Commercial S 50.00 $ Signal Circuit! Limited Energy 1 & 2 Family Dwelling $ 50.00 $ Signal Circuit/ Limited Energy Multi -Family Dwelling $ 93.75 $ wnufactured Home Connection $ 80.00 $ Renewable Electrical Energy 51NA System or Less $ 86.25 $ First 1300 Square Ft. $ 27.50 $ Each Additional 500 Square Ft. or Portion of $ 57.50 $ Each Outbuilding or Detached Garage $ 86.25 $ Each Swimming Pool or Hot Tub $ 43.75x(3.75 Thermostat $ �f a-'7-5 Total Owner as defined by RCW.19.28 261• (1) Owner will occupy the stricture for two years after this elec&Wl permit is FnaHzed. (2) Owner is required to hire an electrical contractor if above said property is forsale, rent or lease. After reading the above statement, I hereby certify that 1 am the owner of the above named propedy or a licensed electrical contractor I am making the electrical installation or alteration in compliance with the electrical laws, N.E.C, RCW. Chapter 1928, WAG Chapter 296.468, The City of PortAngeles Municipal Code, and Utrlity Specifications. Signature of owner, electrical contractororelectrical adminfstrator © Cash O Check X VP I Date: l8/�9 � Creditcarctil J of PREPARED 10/23/09 8 21 20 INSPECTION TICKET PAGE 1 CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 10/23/09 ADDRESS 1039 W 7TH ST SUBDIV TENANT NBR BRAD M / CONNIE ALWARD CONTRACTOR CLAWSON CONSTRUCTION LLC PHONE (360) 457 1473 OWNER BRAD M / CONNIE ALWARD PHONE PARCEL 06 30 00 0 1 5654 0000 APPL NUMBER 09 00000854 RES ADDITION PERMIT BPR 00 BUILDING PERMIT RESIDENTIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS BL2 01 9/22/09 JLL BLDG FOUNDATION STEM WALL TIME O1 00 9/22/09 AP September 22 2009 8 38 49 AM 1pangrle DAVE 461 9295 STEMWALL AFTERNOON September 22 2009 4 15 24 PM jlierly BL9 01 10/21/09 JLL BLDG SHEARWALL TIME O1 00 10/21/09 AP October 21 2009 8 02 36 AM 1pangrle DAVE 461 9295 PLYWOOD EXTERIOR NAILING AFTERNOON October 21 2009 3 48 03 PM jlierly DSD O1 10/23/09 L BLDG DOWN SPOUT DRAINS i.1 October 23 2009 8 20 16 AM 1pangrle DAVE 461 9295 DOWNSPOUT DRAINS COMMENTS AND NOTES PREPARED 10/21/09 8 05 42 INSPECTION TICKET PAGE 3 CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 10/21/09 ADDRESS 1039 W 7TH ST SUBDIV TENANT NSR BRAD M / CONNIE ALWARD CONTRACTOR CLAWSON CONSTRUCTION LLC PHONE (360) 457 1473 OWNER BRAD M / CONNIE ALWARD PHONE PARCEL 06 30 00 0 1 5654 0000 APPL NUMBER 09 00000854 RES ADDITION PERMIT BPR 00 BUILDING PERMIT RESIDENTIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS BL2 01 9/22/09 JLL BLDG FOUNDATION STEM WALL TIME O1 00 9/22/09 AP September 22 2009 8 38 49 AM 1pangrle DAVE 461 9295 STEMWALL AFTERNOON September 22 2009 4 15 24 PM jlierly BL9 01 10/21%09 BLDG SHEARWALL TIME O1 00 20 o, October 21 2009 8 02 36 AM 1pangrle DAVE 461 9295 PLYWOOD EXTERIOR NAILING AFTERNOON COMMENTS AND NOTES PREPARED 9/22/09 8 46 00 INSPECTION TICKET CITY OF PORT ANGELES INSPECTOR JAMES LIERLY ADDRESS 1039 W 7TH ST TENANT NBR BRAD M / CONNIE ALWARD CONTRACTOR CLAWSON CONSTRUCTION LLC OWNER BRAD M / CONNIE ALWARD PARCEL 06 30 00 0 1 5654 0000 APPL NUMBER 09 00000854 RES ADDITION PERMIT BPR 00 BUILDING PERMIT RESIDENTIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS SUBDIV PHONE (360) 457 1473 PHONE BL2 01 9/22/09 L BLDG FOUNDATION STEM WALL TIME 01 00 September 22 2009 8 38 49 AM 1pangrle DAVE 461 9295 STEMWALL AFTERNOON COMMENTS AND NOTES PAGE 7 DATE 9/22/09 ' CITY OF PORT ANGELES DEPARTMENT OF COMMUNITY & ECONOMIC DEVELOPMENT BUILDING DIVISION 1 (9 321 EAST 5TH STREET PORT ANGELES, WA 98362 I Application Number Application pin number Property Address ASSESSOR PARCEL NUMBER Tenant nbr name Application type description Subdivision Name Property Use Property Zoning Application valuation 09 00000854 Date 9/03/09 293382 1039 W 7TH ST 06 30 00 0 1 5654 0000 BRAD M / CONNIE ALWARD RES ADDITION RS7 RESDNTL SINGLE FAMILY 180000 Application desc 470 SF DINING ROOM / MUDROOM ADDITION & REMODEL Owner Contractor BRAD M / CONNIE ALWARD CLAWSON CONSTRUCTION LLC 1039 W 7TH ST P O BOX 2683 PORT ANGELES WA 983635705 PORT ANGELES WA 98362 (360) 457 1473 Structure Information 000 000 RRR Other struct info HARD SURFACE AREA Permit BUILDING PERMIT RESIDENTIAL Additional desc 470 SF ADDITION & REMODEL Permit pin number 152132 Permit Fee 1468 25 Plan Check Fee 954 36 Issue Date 9/03/09 Valuation 180000 Expiration Date 3/02/10 Qty Unit Charge Per Extension BASE FEE 1020 25 80 00 5 6000 THOU BL -100 001 500K (5 60 PER K) 448 00 Permit MECHANICAL PERMIT Additional desc Permit pin number 152157 Permit Fee 72 05 Plan Check Fee 00 Issue Date 9/03/09 Valuation 0 ))) Expiration Date 3/02/10 ( Qty Unit Charge Per Extension BASE FEE 50 00 1 00 14 8000 EA ME FURN/HP/FAU < OR = 5 TON 14 80 1 00 7 2500 EA ME VENT FAN (SINGLE DUCT) 7 25 Permit PLUMBING PERMIT Additional desc l/ Permit pin number 152165 Permit Fee 93 00 Plan Check Fee 00 Issue Date 9/03/09 Valuation 0 Expiration Date 3/02/10 Qty Unit Charge Per Extension Separate Permits are required for electrical work, SEPA, Shoreline, ESA, utilities, private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned for a period of 180 days after the work has commenced. or if required inspections have not been requested within 180 days from the last inspection I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the perfo nce of construction. �� ►C Date Print Name Signature of Contractor or Authorized Agent Signature of Owner (if owner is builder) T:FormsBuilding Division/Building Permit BUILDING PERMIT INSPECTION RECORD PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS — Building Inspections 417-4815 Electrical Inspections 417-4735 Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886 IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE. Inspection Type I Date I Accepted By Comments FOUNDATION Footings Stemwali Foundation Drainage / Downspouts Piers Post Holes (Pole Bldgs.) PLUMBING Under Floor / Slab Rough -In Water Line (Meter to Bldg) Gas Line Back Flow / Water I FINAL Date Accepted by AIR SEAL. Walls Ceiling FRAMING Joists / Girders / Under Floor Shear Wall / Hold Downs Walls / Roof / Ceiling Drywall (Interior Braced Panel Only) T -Bar INSULATION - Slab Wall / Floor / Ceiling MECHANICAL. Heat Pump / Furnace / FAU / Ducts Rough -in Gas Line Wood Stove / Pellet / Chimney Commercial Hood / Ducts IFINAL Date Accepted by MANUFACTURED HOMES Footing / Slab Blocking & Hold Downs Skirting Ij PLANNING DEPT Separate Permit #s SEPA. Parking / Lighting I I ESA. Landscaping SHORELINE. FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/ USE Inspection Type Electrical Construction R W PW / Engineering Fire Planning Building T.Forms/Building Division/Building Permit 417-4735 417-4831 417-4653 417-4750 417-4815 Date Accepted By CITY OF PORT ANGELES DEPARTMENT OF COMMUNITY & ECONOMIC DEVELOPMENT BUILDING DIVISION _ 321 EAST 5TH STREET PORT ANGELES, WA 95362 Page 2 Application Number 09 00000854 Date 9/03/09 Application pin number 293382 Qty Unit Charge Per Extension BASE FEE 50 00 3 00 7 0000 EA PL -PLUMBING TRAP 21 00 1 00 7 0000 EA PL -WATER LINE 7 00 1 00 15 0000 EA PL -SEWER LINE 15 00 Special Notes and Comments The Fire Department has reviewed the project application and has no comments September 1 2009 3 02 54 PM sroberds The proposal will result in a residential remodel for total lot coverage of 14$ and site coverage of 15% No land use issues anticipated August 26 2009 11 32 24 AM Brian 417 4708 Overhead electrical service location will be determined if necessary Customer expressed that they will go underground with service Electrical load calculations and electrical permits are required Public Works Utility Engineering has no requirements for this plan review Other Fees STATE SURCHARGE 4 50 Fee summary Charged Paid Credited Due Permit Fee Total 1633 30 1633 30 00 00 Plan Check Total 954 36 954 36 00 00 Other Fee Total 4 50 4 50 00 00 Grand Total 2592 16 2592 16 00 00 Separate Permits are required for electrical work, SEPA, Shoreline, ESA, utilities, private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned for a period of 180 days after the work has commenced, or if required inspections have not been requested within 180 days from the last inspection I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. Date Print Name Signature of Contractor or Authorized Agent Signature of Owner (if owner is builder) T:FormsBuilding DMsion/Building Permit BUILDING PERMIT INSPECTION RECORD Date Accepted By I Comments FOUNDATION — PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS — Building Inspections 417-4815 Electrical Inspections 417-4735 C� Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886 IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED POST PERMIT IN CONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE. Inspection Type I Date Accepted By I Comments FOUNDATION Inspection Type Date Accepted By Footings Stemwall 417-4735 Construction Foundation Drainageq Downspouts 10 —7-3 —v 4 _T LL_ Fire 417-4653 Piers Planning I Post Holes (Pole Bldgs) Building 417-4815 542.,> I0"12m+c PLUMBING O 3 I 1 1 I to 3u. 5 T-Forms/Building Division/Building Under Floor / Slab Rough-In Water Line (Meter to Bldg) Gas Line Back Flow/ Water IFINAL Date3_I0AtoAccepted by vT L— AIR SEAL Walls Ceiling FRAMING M -4-0q JSists / Girders / Under Floor nS§F ear Wall'f Hnld Downs I ZI-09 TU— Walls % Rooi i Ceiling Drywall (Interior Braced Panel Only) T -Bar INSULATION. Slab Wall /Floor/ Ceiling � MECHANICAL. Heat Pump / Furnace / FAU / Ducts Rough -In Gas Line I Wood Stove / Pellet / ChimneyI Commercial Hood / Ducts I '_I()�(� SL FINAL Date J Accepted by MANUFACTURED HOMES �� j Footing / Slab Q Blocking & Hold Downs I I Skirting PLANNING DEPT Separate Permit #s SEPA. <"1 `X Parking / Lighting ESA. Landscaping SHORELINE. i FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/ USE Inspection Type Date Accepted By Electrical 417-4735 Construction R W PW / Engineering 417-4831 Fire 417-4653 Planning 417-4750 Building 417-4815 542.,> I0"12m+c O 3 I 1 1 I to 3u. 5 T-Forms/Building Division/Building Permit -1 City of Port Angeles Building Division 329 F 5th St. Port Angeles, VILA 98362 PLAN REVIEW Items described here are only a guide to- common questions and missed items during plan review and construction All codes must be complied with (Please read and follow each item') SPECIAL NOTE. Check item #59 first to see if engineering will be needed because of lateral design issues. GENERAL. r 1 Final grading of the property must be done prior to final inspection even if owner is doing required retaining walls Occupancy of the home will not be allowed until there are no slopes steeper than 2 units horizontal to 1 unit vertical or retaining walls are in placer or an accepted soils report is submitted to the City If a soils report was required initially all requirements of the soils report must be accomplished prior to final inspection including submittal of all field reports 2. Acrylic stucco products have special requirements Verify such with the manufacturer Requirements may include tongue and groove foam board under finish control joints special backing boards (sometimes OSB is NOT allowed) self furring or furred -out wire or fabric lath and sometimes installation by a certified installer (certified by the manufacturer) Verify any and all requirements of stucco siding or acrylic stucco products. NO INSPECTION OF LATH OR STUCCO IS REQUIRED, BUT WRITTEN CERTIFICATION BY A MANUFACTURER'S CERTIFIED INSTALLER MUST BE LEFT AT THE JOB SITE UNTIL FINAL INSPECTION BY THE CITY 3 Inspection of shear wall nailing roof sheathing to blocking nailing and hold downs must be requested in addition to standard inspections and before such items are covered up Please specify shear nail roof nail or hold-down inspection when you request these they may be done simultaneously if ready 4 This plan is approved for OSB or plywood exterior wall sheathing only unless the approved plans at the time of permit issuance reflect other materials being used Any change to wall sheathing material after permit issuance must be submitted to the city for review prior to installation An additional plan review fee will be assessed 5. 'Tyvek' or equal approved weather resistive barrier (15# felt is OK) required on the exterior side of all walls regardless of the type of siding used This includes garage walls gable portion of end walls and cripple walls (at stepped foundation conditions) Apply over exterior sheathing or over studs in single-wall construction T 1 11 or similar panel siding must have 'Tyvek' or equal over the studs. 6 Exterior windows and doors shall be flashed with approved materials and caulking Caulked trim material over the window or door flange is not an acceptable method 7 Overall dimensions of house plan must match site plan dimensions Verify any special requirements for buildings located close to property lines R302 T Building/HandoutsiResidentiai Plan Review Guidelines (Rei C3-18-09) Page 1 of 8 LIFE -SAFETY & MISC ITEMS 8. Sleeping rooms must have an egress window with 5 7 s f net clear opening 24 min height, 20' min width 44 maximum from floor to window sill Windows must meet all 4 dimensions R310 1 9' Safety or tempered glass shall be -used in. windows that are (R308 4) • Adjacent to a door (24 arc of either edge of the door in a closed position) • That are closer than 18' to floor (AND individual pane is more than 9 s f top edge more than 36" a.f f and walking surface within 36' horizontally of the window in question) • Walls enclosing a tub or shower (AND within 60" of the drain or within 60' of walking surface) R308 4 • Adjacent to stairways landings and ramps within 36" horizontally of a walking surface (AND less than 60" a f f of the walking surface) • Adjacent to stairways within 60" of the bottom tread of the stair in any °direction (AND less than 60" a f f ) 1'0' Under -stair areas that are enclosed and accessible must be sheetrocked 1/2" GWB on walls and underside of the stairway R311 2.2 11 Stairways shall have 10' min tread and 7 3/4 max. rise R311 5 12. Provide `36" high guards (with 4" max. spacing on rails) at porches balconies and raised floor surfaces more than 30" above adjacent ground or floor .R312 1 13 Smoke detectors required at all bedrooms hallway or room adjacent to bedrooms and at any ceilings that are more than 24" above adjacent ceiling All smoke detectors interconnected and hardwired with battery back-up .R3'131 14 Garage/house separation wall is 1/2" GWB door must be 20 min rated or 1 3/8" solid -core If living space above use 5/8' GWB Type "X at the ceiling AND 1/2' GWB at walls that support the floor above Ducts in garage must be 26 -gage sheet steel and have no openings in the garage R309 15 Exterior stairways must have a light located near the top landing of the stairway switched from inside (ori have motion -activation device) R303 6 16 Minimum room areas- must be provided (120 s f min in at least one room 70 s f min all other .habitable rooms 7 foot min dimension in all habitable rooms) R304 1 17 Minimum ceiling heights must be provided (7 foot min with some exceptions) R305 1 FOOTINGS, FOUNDATIONS, AND CRAWL SPACES 18 All footings including exterior isolated pad footings must have a 24" (min ) depth from. the bottom of the footing to finished grade R403 1 4 1 19 All footings shall be supported on undisturbed natural soils or engineered fill Any placement of fill material that will support a structure will require a geotechnical investigation and report submitted to the City prior to placement of footings R401 2 & R403 1 20 Lots shall be graded to drain surface water away from foundations The grade shall fall 6" in the first TEN feet around the perimeter of the structure R401 3 21 Top surface of footings shall be level Bottom surface of footings shall not have a slope that exceeds (1), unit vertical in (10) units horizontal Any necessary stepping of the foundation must be approved during plan review or prior to installation of the foundation R403 1 5 T Building/Handouts/Resideni al Plan Review Guidelines (Rev 03-18-09) Page 2 of 8 22. Wood sill plates of all exterior walls interior bearing walls (slab -on -grade) and interior shear walls (slab -on - grade) must be anchored to foundation or slab with '/2 " X 10' J -bolts with a 2" X 2' X 3/16" plate washer Anchor bolts to be placed a maximum of 12' -and no closer than 3 '/Z from the ends of the sill plate Each piece of sill plate must have a minimum of (2) anchor bolts Anchor bolts shall be spaced no further than 6 feet apart. (Special spacing and sizing conditions may apply at alternate braced wall. panels) R403 1 6 r 23 6' clearance required from finish grade to foundation mudsill plate R319 24 3 1/2" (min ) thickness for all concrete slabs -on -grade R506 1 25 Footing and foundation wall SIZES for two pour system (Foundation. walls NOT over 5feet in height) • Footing supporting single story- 12" wide X 6" thick. • Foundation wall supporting single story- 6' thick • Footing supporting two stories- 15" wide X 7' thick. • Foundation wall supporting two stories- 8' thick Foundations that support more than two stories require an engineered design. 26 Footing and fnd REINFORCEMENT for two pour system ( fnd walls NOT over 5 .feet in height) (Footings "supporting single or two stories) • One continuous #4 horizontal rebar placed at center of footing with 3" (min ) clearance from dirt. (Foundation walls not over 5 feet in height) • One continuous #4 horizontal rebar placed within the top 12' of the wall • #4 vertical rebar placed at 48 inches o c max (wet set ok) with a 6 -inch 90 -degree hook. A minimum of (2) vertical bars to be placed at front garage wall returns 27 Monolithically poured foundation systems • Bottom of footing shall be 12' wide (min ) and extend to 24" below finished grade minimum • Footing shall have either one #5 continuous horizontal rebar placed at center and 8" above bottom of footing or (2) #4 continuous horizontal rebar placed at center and in the middle third of the footing measuring vertically • 3 1/2' minimum slab thickness • When a monolithic system is used to support heated spaces an R40 insulation board must be installed on the outside of the foundation extending from bottom of footing to top of slab Exposed foam insulation above grade must be protected from damage and sun with approved materials The material used must extend a minimum of 12" below grade 28 Basement Walls (up to 9 feet) or Stem Walls (over 5 feet) or STEPPED FOUNDATIONS There are special restrictions for this type of foundation wall under the new code In plan view the length of this type of wall cannot exceed 35 feet. For stepped foundations this wall cannot exceed 7 feet, high otherwise the floor joists must connect DIRECTLY to the wall (for bracing the foundation wall) WET -SETTING IS NOT allowed for the alternating hooksinto the footing There are special blocking requirements if any of these conditions cannot be met (note on the mans!) See R404 1 29 Under -floor pier pads supporting uniform load of wood framed floors shall- be 18"x 18" x 8' (min ) Point loads from other than floor girders will require larger footings sized according to the concentrated load R403 1 1 30 Beams and/or girders in crawl space must meet span requirements for the loads imposed (from floor joists and from any point loads) R501 2 T Buildi a,i-landouts/Residential Plar Review Guidelines (Rev 03-18-09) Page 3 of 8 I 31 Access shall be provided to all under -floor spaces Access openings through the floor shall be a minimum of 18" x 24" Openings through a perimeter wall shall be a minimum of 16' x 24" R408 3 32. Under floor spaces shall be ventilated by openings .providing one (1) square foot of vent area per 150 square feet of crawl space area One such ventilating opening shall be within 3 feet of each corner of the building 8408 2 33 A ground cover of 6 mil black polyethylene or approved equal shall be laid over the ground within crawl spaces The ground cover shall be overlapped 12" and extend to the foundation wall WSEC 502 1 6 7 34 The under -floor grade shall be cleaned of all vegetation and organic material All wood forms and constructiondebris shall be removed prior to final inspection R408 35 Thickened -slab footings must be 12' min total depth '(top of conc slab to bottom of footing = 12" total) (Revised from IRC) 36 Foundation cripple walls shall be framed of studs not less .in .size than the studding above Cripple walls with a height less than 14 inches shall be sheathed on one side with a wood structural sheathing or shall be of solid blocking Cripple walls count as an additional 'story" for lateral purposes R602 9 FLOOR FRAMING 37 18' (min ) clearance beneath all floor joists and 12" (min ) clearance beneath floor girders (beams) in crawl spaces R308 38 Span of all joists (including 2nd level joists) must meet minimum live load of 40 psf (general living areas) or 30 psf (sleeping rooms) together with dead load of materials used R301 5 and Table R301 5 39 Span of beams for 2nd level or other supporting elements must meet minimum live and dead load requirements R3015 40 Wood posts in the crawl space shall have a connection to the concrete pier and a moisture barrier between the post and footing (or use pressure -treated posts) R319 & R407 41 Solid -sawn floor joists shall .be blocked at all bearing points. Engineered floor joists shall be installed per manufacturer's specifications R502 7 42. Cutting drilling and notching of floor joists shall not exceed the limitations in Figure R502 8 43 Cutting drilling and notching of engineered 1 -joists shall be in accordance with the manufacturer's specifications R502.8 2 44 All concentrated point loads originating from roof or floor load shall .be transferred to bearing footings or foundation walls Continuous support shall be provided by members that are equal in cross-sectional area to the area of the load imposed and shall not be reduced in size at any point. 45. Wood members supported in concrete or masonry pockets shall have a 'l2 inch air space provided at tops, sides and ends of the member 46 All foundation plates sills and sleepers bearing on a concrete foundation or slab that is in direct contact with the ground shall be pressure treated All wood -framing members that rest on concrete foundations and are within 8 of exposed ground shall be pressure treated R319 Building/Handouts/Residential Plan Review Guidelines (Rev 03-18-09) Page 4 of 8 47 Sawn lumber floor joists shall have 1'/z (min ) bearing and shall lap 3 min at intermediate girders Engineered I -joists shall have 1 3/4 (min ) bearing (or per manufacturer's specifications) 48. Floor joists that are parallel to bearing partitions shall be doubled Some heavier load cases will require girder beams or pony. walls Bearing partitions perpendicular to floor joists shall, not be offset from the sLpporting girder more than the depth of the joists .unless the floor joists are of sufficient size to carry the load R502 4 49 Floor cantilever spans shall not exceed the depth of the nominal floor joists Floor cantilevers constructed in accordance with Table R502 3 3 (1) shall be permitted when supporting a light framed bearing wall and roof only R502 3 3 50 Block in between floor joists beneath, all interior braced walls (for walls perpendicular to joists)' or align floor joist with interior braced wall (see item #63-T) WALL FRAMING 51 Wall studs taller than 10 feet shall have a stud height analysis by a professional- engineer or architect. Table R602.3 5 52. Non -load bearing stud heights shall be in accordance with Table R602.3 (5) 53 Studs shall be a minimum #3 grade standard grade or stud grade lumber R602 2 54 Where joists trusses or rafters are spaced more. than 16" o c. and the bearing studs below are spaced at 24" o c such members shall bear within 5" of the studs below unless the top plates are double 2x6 or a third plate is added R602 3 3 55. Headers over windows and doors must meet minimum .requirements for spans and imposed loads verify -point loads over openings (from trusses or other conditions) and size headers accordingly Headers must be noted with size type and grade of lumber being used GENERAL NOTE STATING ALL HEADERS SHALL BE is acceptable 56 Interior bearing walls must have headers over openings and must be supported to a foundation 57 Top plate splices shall be offset a minimum of 24 inches R602 3 2 58. Fire -blocking required at dropped ceilings soffits coved -ceiling areas and every ten feet horizontally and vertically at framed walls R602 8 59 Port Angeles is in Seismic Zone D1 Wind zone of 100 MPH Category C (within 1500 ft from shore line is Category D) per the 2006 IRC When a house is considered IRREGULAR by any ONE the definitions below the code will NOT allow prescriptive bracing for Seismic Zone C and the entire house must have a lateral analysis and design by a licensed engineer (R301 2 2 2 2) Per that section of the code NO MIXING OF PRESCRIPTIVE AND ENGINEERED LATERAL SYSTEMS IS ALLOWED UNDER THIS NEW 2006 IRC. The following are items that constitute an IRREGULAR BUILDING per the 2006 IRC A. Exterior braced wall lines must be in one plane vertically from foundation to the uppermost story (basically the upper floor must match the lower floor footprint) The most common area where problems like this occur is in a garage with a second floor over it. To qualify for prescriptive bracing the second floor joists must extend to the exterior walls of the garage If this does NOT occur then your proposed house is IRREGULAR If the joists do extend to the exterior walls of the garage then the setback of the second floor walls cannot be more than four (4) feet setback from the garage walls T Building/Handouts/Pe. ,dential Plan Review Guidelines (Rev 03-18-09) Page 5 of 8 (see p 44 of the 2006 IRC) Rooms created by roof trusses are OK under this provision (such as bonus rooms over garages formed by the trusses/rafters) B The perimeter of all floor diaphragms and all roof diaphragms must be supported on WALLS below If you have beams holding up any part of the perimeter of a floor or a. roof then your proposed' house is IRREGULAR The. most common,place you will find, this problem is at large covered porches and patios where the roof is supported only by post and beams Such covered :porches and patios also make the building IRREGULAR Related to this are areas of discontinuous diaphragms especially changes in plate line .heights which also are considered as separate 'roofs and therefore make the building IRREGULAR C In any elevation of the exterior the braced walls from an upper level wall must NOT occur over a window or door In general this means that the windows of the upper story must. align with the windows .of the lower story There are =some .exceptions. based on up-sizing. the- header in, the window below (see 2006 IRC p 44 for details) .D- When an opening in,a floor or roof (such as a balcony -overlook area or a courtyard area): exceeds the lesser of 12 feet or 50% of the least dimension then your proposed house is -IRREGULAR E. When portions of a floor level are vertically offset (such as a sunken room) then your proposed house Js IRREGULAR This does not apply to a slab-on=grade floor F When braced wall lines do not occur in two perpendicular directions .(such as portions of the house or garage at an angle to the rest of the building) then. your.proposed. house is IRREGULAR G If you have any portion of the above -grade walls that use masonry or concrete construction then your proposed house is IRREGULAR Stepped foundations that create a daylight basement situation are OK under this provision and do.not make an irregular structure 60 THIS APPLIES TO ALL LATERAL BRACING (ITEMS 61 THRU 65) Add up all lengths of braced panels (4 foot braced panels 2 -8' alt braced panels and 24 or 16' portal frames COUNT as 48' of length each portal frame counts as a. total of 48' of bracing length—not 2 times 48") along the wall in question The total length of braced walls must be at least 16% of the entire wall length AND the panels must occur at least every 25 feet along the wall For 1S' story of 2 -story house 30% of the entire wall length must be braced walls Check this for all braced wall lines including INTERIOR WALLS and including the front wall of a garage if it is not part of another braced wall line (i a the garage sticks out in front of the house more than 4 feet) See also #65 T below for areas where MORE than 35 feet between wall lines is needed 61 Garage lateral bracing systems with no 2nd floor above H Portal Frame for Garages (16' side panels @ 8 foot max. high walls 20" side panels @ 1.0. foot -.max. high walls) Alternate Braced Walls—single-story condition (2'-8' min width X 10 foot max. height) sheathed on one side (interior or exterior OK) with min 3/8' OSB or plywood and nailed with 8d common or gals box nails and blocked at all edges Two (2) anchor bolts in sill plate & two (2) hold-down devices @ furthest studs (1800 pound capacity hold-downs) J Alternate Braced Walls—first floor of two-story condition (2'-8" min width X 10 foot max. height) sheathed on BOTH interior and exterior sides of wall with min 3/8" OSB or plywood and nailed with 8d .common or galv box nails and blocked at all edges Two (2) anchor bolts in sill plate & two (2) hold- down devices @ furthest studs (3000 pound capacity hold-downs) There are some provisions for plate lines up to 12 feet high see Table R602 10 6 (basically a wider wall 3 -6' min length for 12 feet high) K. Front Garage Panels—no hold-downs required L. The exterior braced wall lines in a detached or attached garage cannot be more than 35 feet apart in either direction or interior braced walls must be provided 62. 1st. Floor Conditions Four (4) foot solid walls at all corners and at every 25 feet along any braced wall line OR use one of the methods below M Portal Frame for a House (slab -on -grade floors ONLY) 16" min width for one-story structures 24 min width for first floor of 2 story T Building/Handouts/Residential Plan Re­iew Guidelines (Rev 03-18-09) Page 6 of 8 N Alternate Braced Walls—single-story condition (2'-8' min width X 10 foot max. height) sheathed on one side (interior or exterior OK) with min 3/8' OSB or plywood and nailed with 8d common or galv box nails and blocked at all edges Two (2) anchor bolts in sill plate & two (2) hold-down devices @ furthest studs (1800 pound capacity hold-downs) O Alternate Braced Walls—first .floor of two-story -condition (2'-8' min width X 10 foot, max height) sheathed on BOTH interior and exterior sides of wall with min 3/8" OSB or plywood and -nailed with 8d common or galv box nails and blocked- at all edges Two (2) anchor bolts in sill plate &'two (2) hold- down devices @ furthest studs (3000 pound capacity hold-downs) There are some provisions for.plate lines up to 12 feet high see Table R602 10 6 (basically a wider wall .3 -6' min length for 12 feet high) P "Simpson" Brand StrongWalls—this method is still available following all the manufacturer's specifications for connections Q. Entire House Sheathed with OSB or Plywood—this method. allows smaller .side panels- than 4, feet in accordance with Table R602 10 5 CHECK THE OPENING HEIGHTS ADJACENT TO THESE PANELS! 63 Vt Floor Conditions – Braced wall, (any of the methods .listed above) .must start at no more than 12 5 feet away from the corner of the braced wall lines and then at every 25 feet (min ) along the wall line 64 2nd Floor Conditions Braced walls (either of the methods listed below) must be within 12 5 feet of the corner of the wall line in question R. Standard four (4) foot panels on 2nd levels can start at no more than 12.5 feet away from the corner S Entire House Sheathed with OSB: or Plywood—this method allows smaller side panels than 4 feet in accordance With Table R602 10 5 CHECK THE OPENING HEIGHTS ADJACENT 7O THESE PANELS! 65. Exterior braced wall lines (or together with some interior wall lines) cannot be more than 35 feet apart. T Certain areas can be up to 50 feet apart between wall lines IF there is additional bracing along the exterior wall in question (50/35 = 1 43 more bracing than normally required or in other words 23% of the total wall in bracing for 1 -story wall 43% of the total wall in bracing for 1 st story of a 2 -story house) R602 10 1 1 Exception 1 and 2 U Interior Braced Walls can be used when exterior walls are more than 25 feet apart. Interior. Braced Walls are minimum 1/2" GWB both sides of wall for a minimum length of 48' use 5d nails or screws at 7' o c Sole plate of wall must be attached to thickened slab footing (see item #22 above). with 1/2" anchor bolt @ 6'-0" o c. or solid blocking (walls perpendicular to joists) or LINE UP JOIST with braced wall (walls parallel to joists) 66 The roof sheathing MUST nail into SOLID blocking and the block must connect to the double top plate either with clips or toe -nailed (for blocks that are top -beveled) with 8d @ 6' o c. For ventilation use not more than two (2) 2' diameter holes BLOCKING MUST OCCUR AROUND ENTIRE PERIMETER OF ALL ROOFS Table R602 3'(1) This applies to all houses both engineered AND prescriptive bracing ROOF & ATTIC 67 Truss drawings must show reactions of all girder trusses point loads onto headers must have headers sized accordingly point loads over 5000 lbs onto double -top plates must be checked for bearing capacity Use Simpson brand TBE4 or TBE6 as needed to spread the load - 68 Truss bottom chord live load must be minimum of 10PSF (see Table R301 5) Trusses must be sized for the roof coverings specified on the plans (concrete the etc ) and roof structure must be able to hold up the roof (beams headers etc sized for roof loads) R802 10 2 69 Ice Shield is required for roofs up to 6 12 (6 12 and over DO NOT require ice shield) R905 2 7 1 7 Building/l- andouts/Residential Plan Review Guidelines (Rev 03-18-09) Page 7 of 8 70 Attic ventilation must be provided at 1/150th of the attic area or 1/300th of the attic area if 50% of the venting can be 3 feet above the eave venting (roof jack vents are 49 sq in./vent ridge vents at 12 sq in./foot) R806 1 71, Attic mechanical equipment, need light and switch near opening and electric outlet. .Access opening to such mechanical equipment must -be no further than 20 feet from equipment with 22" wide (min ) walkway from access opening to the equipment. 72. Attic access required 22' X 30" min and shall be in hallway or other readilyaccessible location R807 1 MECHANICAL. 73. Appliances located .in a garage or carport shall be protected from damage from vehicles .M1307 3 1 r w 74 Gas appliances located in a garage shall be raised 18" min ,above finish floor G2408 2 (305 3) 75. Ductwork that extends below grade (such as in the garage floor) shall;be encased in 2" min concrete on all sides and bottom in addition to the R-10: insulation foam board 603 8 IMC 76 Dryer exhaust ducts shall not exceed 25 feet in length The maximum lengthof the duct shall be reduced 2 5 feet for each 45 -degree bend and 5 feet for each 90 -degree bend Longer lengths in accordance with the manufacturer's listing will be allowed Screws shall not be used to connect any dryer duct _materials M 1:501 3 77 Flex duct connections to -sheet metal transition ducts shall.'have the inner sleeve taped with approved materials prior to securing the flex duct with a zip tie or similar fastener 304 IMC 78. Flex duct shall be supported every 4 feet and have no sag that exceeds'/ per foot. 79 All exhaust fan ducts shall be connected to the fan housing and termination fittings with a minimum of 3 sheet metal screws and be sealed with approved tape or mastic. 80 Exhaust fans required 50 cfm in bathrooms 100 cfm in kitchen 50 cfm min in laundry room and one fan sized for whole -house ventilation 302 2 2 WSVIAQ 81 Fuel -burning equipment shall not .be installed in a closet, bathroom or a room readily usable as a bedroom 82. Water heaters must be secured to structure with straps around tank at 1/3 points to resist lateral displacement. M1307 2 PLUMBING '83 Cleanouts shall be installed on all sinks and at the upper end of all building drains including any horizontal drain branches greater than 5 feet in length from the main line A cleanout shall also be installed on the exterior of the house within. 24 Inches of the foundation wall level with final grade and shall have a threaded type cap installed 84 30' min width for toilet and 24" clear space in front of toilet (UPC) 85. Water heaters pressure relief and the required drain pan shall have a drain that is % ID copper or cpvc material NO coil material shall be allowed per code and no reduction in the pipe shall reduce the ID of the material less than % Pex type is a coil material and is not allowed for this application T Building/HandoutsiResidentiai Plan Review Guidelines (Rev 03-18-09) Page 8 of 8 ��... �--�.. �C �.�� `` -� ��* :� %� � t t , I' I CITY OF PORT ANGELES FIRE DEPARTMENT PERMIT 321 East 5" Street, Port Angeles, WA 98362 Application Number 09 00000903 Date 9/02/09 Application pin number 701848 Property Address 1039 W 7TH ST ASSESSOR PARCEL NUMBER 06 30 00 0 1 5654 0000 Application type description FIRE ABANDON TANK INSPECTION Subdivision Name Property Use Property Zoning RS7 RESDNTL SINGLE FAMILY Application valuation 0 Application desc Abondon oil tank in place Owner Contractor ALWARD BRAD M/CONNIE PETTIT OIL CO 1039 W 7TH ST 638 MARINE DRIVE PORT ANGELES WA 983635705 PORT ANGELES WA 98362 (360) 457 9404 Permit UNDERGROUND TANK RES Additional desc OIL TANK ABONDONED IN PLACE Permit pin number 152843 Permit Fee 15 00 Plan Check Fee 00 Issue Date 9/02/09 Valuation 0 Expiration Date 3/01/10 Qty Unit Charge Per Extension BASE FEE 15 00 Fee summary Charged Paid Credited Due Permit Fee Total 15 00 15 00 00 00 Plan Check Total 00 00 00 00 Grand Total 15 00 15 00 00 00 09-09-6� This permit becomes null and void if work authorized is not commenced within 180 days, if work is suspended or abandoned for a period of 180 days afer the work has commenced, or if required inspections have not been requested with 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct, All provisions of recognized standards, laws and ordinances governing this type of work will be compled with whether specified herem or not. The granting of this permit does not presume to give authority to violate or cancel the prov .o of any state or local law regu ,!Fg the work specified in the permit. Signature of Contractor or Authorized Agent Date Signature of Owner- (if Owner is builder) Date FIRE PERMIT INSPECTION RECORD Call 360-417-4655 for fire inspections Please provide a minimum 24-hour notice It is unlawful to cover, insulate -� or conceal any work before inspected and accepted. Post permit in a conspicuous location. Q W KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE Inspection Type I Date Passed I Comments FIRE SPRINKLER Underground piping hydrostatically tested Underground piping flushed IInterior piping hydrostatically tested Interior piping inspection Dry system air tested at 40 psi (24 hours) Sprinkler final I FIRE ALARM Rough -in inspection Alann final ` LP -GAS Underground piping inspection/pressure test Above ground piping inspection/pressure test Tank (container) inspection Appliance inspection LP -gas final UNDERGROUND STORAGE TANK (UST) ABANDONMENT Removal of flammable/combustible liquids Tank appropriately abandoned UST abandonment final PERMIT OTHER (specify) permit final GENERAL COMMENTS O Completed by Contractor - Test # 1 Piping pressure test psi Time initiated Test #2 Piping pressure test psi Time initiated 9-9-09 Fr KDD 2/15/00 PORT ANGELES FIRE DEPARTMENT Abandonment of Residential Fuel Storage Tank 1,100 Gallons or Less Application for Permit Please call the Fire Marshal's Office at 417-4653 for assistance with the processing this ,permit. Site Address 10 3 9 -7tv-) S+ Name of Apphcant: 4-4--`w L L. c. rVA- &tM A2,4,v4U), Address. 10; 9 j 7 Site Owner- 61tioleopiwle A-4-.j,"v Date: (— I- - 0 7 Telephone: 340 �S;7 Z614`1 ITelephone: Permits are issued at the City of Port Angeles Pen -nits Counter located at City Hall, 321 E 5', Port Angeles, WA. Permit fee $15 00 paid to the City of Port Angeles Fire Department. Date paid. Date Issued, Date Issued, Issued by - Additional Comments I have read and understand the. recLuirements of this application Applicant's Signature FP 25 A (Revised 12/9/04) Page 1 of 3 Section I - Required Information Applicant is required to furnish the following information on the space provided on the next page A site plan showing the number size, and location of the underground storage tank with reference to the existing home. 2 Specify the type of liquid which was stored in the tank. Section II - Requirements and Limitations Issuance of a permit is subject to compliance with the listed -requirements and approval by a field inspection of the Port Angeles Fire Department. Residential underground storage tanks may be abandon in place or removed. 1 There shall be no welding, cutting, or other sources of ignition in the area while abandoning operations are in progress. Welding or cutting on tanks require a separate permit from the Port Angeles Fire Department. 2 Removal of all flammable and combustible liquids from the tank and all connecting lines shall be pumped out. Please use a hand pump or other means to remove remaining flammable or combustible liquids as far as practical. 3 If the tank is removed and stored on site temporarily, the tank shall be placed in a secure location and blocked to prevent movement. The tank would be required to be merted prior to being transported. The hole created by removing the tank shall be filled with a suitable material (earth, sand, etc ) 4 There are three options for the abandonment of residential fuel storage tanks. All three options require that the tank is first completely pumped out. Option #I — The tank and all associated fill and vent piping can be removed completely This is generally the best method, however it is also the most expensive. Option #2 — The tank fill and vent pipes are removed, then the tank is filled completely with an inert mixture such as a sand slurry If Option #1 (complete removal) is not chosen, then this method is REQUIRED if the tank is within 5 feet of a property line, driveway sidewalk, swimming pool, deck or building foundation. Option #3 — The tank fill and vent pipes are removed below grade and capped. The tank is left in place If using this method, the applicant must read, understand and sign the following statement: "In using this method, I understand that the void created by the tank may cause a collapse of the adjacent ground if the tank rusts out over time." �> A licant Signature �`yv Pp � Date. ! Z 0,9 FP 25 A (Revised 12/9/04) Page 2 of 3 Site Diagram A -A 1 f:!j To be completed by Fire Department Method of abandonment: ( ) Tank removed ( ) Tank filled with Inert mixture ( ) Tank vent and fill lines capped below grade FP 25 A (Revised 12/9/04) Page 3 of 3 ELECTRICAL PERMIT CITY OF PORT ANGELES 360-417-4735 Application Number 09 00000859 Date 8/21/09 Application pin number 008500 Property Address 1039 W 7TH ST ASSESSOR PARCEL NUMBER 06 30 00 0 1 5654 0000 Application type description ELECTRICAL ONLY Subdivision Name Property Use Property Zoning RS7 RESDNTL SINGLE FAMILY Application valuation 0 Application desc 2000 sqft remodel service 30 circuits Owner Contractor ALWARD BRAD M/CONNIE BOTERO & SON ELECTRICAL 1039 W 7TH ST 940 TAMARACK WAY PORT ANGELES WA 983635705 PORT ANGELES WA 98362 Permit ELECTRICAL ALTER RESIDENTIAL Additional desc Permit pin number 152215 Permit Fee 153 75 Plan Check Fee Issue Date 8/21/09 Valuation Expiration Date 2/17/10 Qty Unit Charge Per 30 00 2 0000 ECH EL BRANCH CIRCUIT W/FEEDER 1 00 93 7500 ECH EL 0 200 SRV FEEDER Fee summary Charged Paid Credited Permit Fee Total 153 75 153 75 00 Plan Check Total 00 00 00 Grand Total 153 75 153 75 00 INSPECTION TYPE I DATE DITCH 10/29 1,�-7 SERVICE 16 Ile /Z)? ROUGH IN FINAL 31g !ro COMMENTS 00 0 Extension 60 00 93 75 Due 00 00 00 RESULTS ( INSPECTOR. Signature of owner or Electrical Contractor X Date __j City of Port Angeles Permit Application Building Division/Electrical Inspections 321 East Fifth Street - P.0 Box 1150 Port Angeles Washington, 98362 Ph. (360) 417-4735 Fax: (360) 417-4711 Date 1 & 2 Single Family Dwelling _ Multi -Family or Commercial* _ Commercial Addition / Alteration / Remodel / Repair* Plan Review May Be Required Please Complete Electrical Plan Review Information Sheet Job Address. I r) 5'1 r .) '1 f h Building Square Footage -� ` � T` -G O n Description of above ZOO 0 r.,o --- - - Owner Information � Contractor Information Name __ A- -A r v' Name (�' o e'f0 t so el', Y t Gc Mailing Address: to 3'A 'i -lam Mailing Address: qy() Te- w.arac--Lr- City. e VA State- Zip L J ✓A '10'56 3 City &,,(k j4ha et,e N State. wA Zip- 10156 Z Phone Fax: Phone 5(o0 -'YS2-f 0c0Xx: License # / Exp License # / Exp Unit Charae Qty Total (0tv Multiplied by Unit Charge) $ 93.75 �_ $ Service/Feeder 200 Amp. $113.75 $ Service/Feeder 201-400 Amp. $160.00 $ Service/Feeder 401-600 Amp $205.00 $ Service/Feeder 601 1000 Amp. $291.25 $ Service/Feeder over 1000 Amp. $ 2.00 $ Branch Circuit W/ Service Feeder $ 57.50 $ Branch Circuit W/O Service Feeder $ 2.00 $ Each Additional Branch Circuit $ 72.50 _ _ $ _- Temp. Service/ Feeder 200 Amp. $ 86.25 $ Temp. Service/Feeder 201-400 Amp. $116.25 $ Temp. Service/Feeder 401-600 Amp. $131.25 $ Temp. Service/Feeder 601 1000 Amp. $ 75.00 $ Portal to Portal Hourly $ 69.00 $ Sign/Outline Lighting $ 75.00 $ Signal Circuit/ Limited Energy Commercial $ 50.00 $ Signal Circuit/ Limited Energy 1 & 2 Family Dwelling $ 50.00 $ Signal Circuit/ Limited Energy Multi -Family Dwelling $ 9375 $ Manufactured Home Connection $ 80.00 $ Renewable Electrical Energy 5KVA System or Less $ 86.25 $ First 1300 Square Ft. $ 27.50 $ Each Additional 500 Square Ft. or Portion of $ 57.50 $ Each Outbuilding or Detached Garage $ 86.25 $ Each Swimming Pool or Hot Tub $ 43.75 $ Thermostat $ Total Owner as defined by RCW.19.28.261 (1) Owner will occupy the structure for two years after this electrical permit is finalized. (2) Owner is required to hire an electrical contractor if above said property is for sale, rent or lease. After reading the above statement, I hereby certify that I am the owner of the above named property or a licensed electrical contractor I am making the electrical installation or alteration in compliance with the electrical laws, N.E.C. RCW. Chapter 19.28, WAC Chapter 296.466, The City of Port Angeles Municipal Code, and Utility Specifications. Signature of owner electrical contractor or electrical administrator ❑ Cash ❑ Check X r% " Date: ! L 0 t Credit Card # V _ � 1. � - ELECTRICAL PERMIT CITY OF PORT ANGELES 360-417-4735 Application Number 09 00000858 Date 8/21/09 Application pin number 927000 Property Address 1039 W 7TH ST ASSESSOR PARCEL NUMBER 06 30 00 0 1 5654 0000 Application type description ELECTRICAL ONLY Subdivision Name Property Use Property Zoning RS7 RESDNTL SINGLE FAMILY Application valuation 0 Application desc Temp pole for construction Owner Contractor ALWARD BRAD M/CONNIE BOTERO & SON ELECTRICAL 1039 W 7TH ST 940 TAMARACK WAY PORT ANGELES WA 983635705 PORT ANGELES WA 98362 Permit ELECTRICAL TEMPORARY SERVICE Additional desc Permit pin number 152207 Permit Fee 72 50 Plan Check Fee 00 Issue Date 8/21/09 Valuation 0 Expiration Date 2/17/10 Qty Unit Charge Per Extension 1 00 72 5000 ECH EL TEMP SRV 0 200 SRV FDR 72 50 Fee summary Charged Paid Credited Due Permit Fee Total 72 50 72 50 00 00 Plan Check Total 00 00 00 00 Grand Total 72 50 72 50 00 00 INSPECTION TYPE I DATE DITCH SERVICE /,4 4 ROUGH IN FINAL�Zbt V7 COMMENTS Signature of owner or Electrical Contractor X RESULTS A Date INSPECTOR. 95 NO 14 City of Port Angeles Permit Application Building Division/Electrical Inspections 321 East Fifth Street - P.O. Box 1150 Port Angeles Washington, 98362 Ph: (360)411.4735 Fax: (360) 417-4711 Date. 1 & 2 Single Family Dwelling Multi -Family or Commercial" Commercial Addition / Alteration / Remodel / Repair' Plan Review May Be Required Please Complete Electrical Plan Review Information Sheet Job Address: 11) 5'5 f . ) "7 t h Building Square Footage: Description of above 7_60 av-c. r vj Owner InformationContractor Information Name. (r(-" Ir ( _r) v, 6, 1e i� I w 0,VJ Name- G o e, -r0 t So r Mailing Address: (a 3I vv 1 Mailing Address: R W) Tc.vv.c.r0.c✓ _ City. P VA State. Zip. _W ✓A -1 a 36 3 City' P�,tk t�1Na Ccs S State w►f1 Zip `[ �i' �G Z Phone. Fax: Phone d G "1I SZWNA: License # I Exp License # I Exp. Unit Charoe Qty Total (Qtv Multiplied by Unit Charge) $ 93.75 $ Service/Feeder 200 Amp. $113.75 $ Service/Feeder 201A00 Amp. $160.00 $ Service/Feeder 401-600 Amp. $20500 $ Service/Feeder 601 1000 Amp. $291.25 $ Service/Feeder over 1000 Amp. $ 2.00 $ Branch Circuit W/ Service Feeder $ 57.50 $ Branch Circuit W/O Service Feeder $ 2.00 $ Each Additional Branch Circuit $ 72.50 _ $,2. S Temp. Service/ Feeder 200 Amp. $ 86.25 $ Temp Service/Feeder 201-400 Amp. $116.25 $ Temp Service/Feeder 401-600 Amp. $131.25 $ Temp. Service/Feeder 601 1000 Amp. $ 75.00 $ Portal to Portal Hourly $ 69.00 $ Sign/Outline Lighting $ 75.00 $ Signal Circuit/ Limited Energy Commercial $ 50.00 $ Signal Circuit/ Limited Energy 1 & 2 Family Dwelling $ 50.00 $ Signal Circuit/ Limited Energy Multi -Family Dwelling $ 9375 $ Manufactured Home Connection $ 80.00 $ Renewable Electrical Energy 5KVA System or Less $ 86.25 $ First 1300 Square Ft. $ 27.50 $ Each Additional 500 Square Ft. or Portion of $ 57.50 $ Each Outbuilding or Detached Garage $ 86.25 $ Each Swimming Pool or Hot Tub $ 43.75 $ Thermostat $ 7Z Total O Z v\ Co Owner as defined by RCW.19.28.261 (1) Owner will occupy the structure for two years after this electrical permit is finalized. (2) Owner is required to hire an electrical contractor if above said property is for sale, rent or lease. After reading the above statement, I hereby certify that I am the owner of the above named property or a licensed electrical contractor I am making the electrical installation or alteration in compliance with the electrical laws, N.E.C. RCW. Chapter 19.28, WAC. Chapter 296-46B, The City of Port Angeles Municipal Code, and Utility Specifications. Signature of owner electrical contractor or electrical administrator ❑ Cash ❑ Check X Date: I Z I 1 U C'— Credit Card # d V1. t t 1 Y�3 PORTAE �r BUILDING PERMIT APPLICATION Print in ink CITY OF PORT ANGELES Attn. Building Permit Technician 321 E. Fifth St. Port Angeles WA 98362 (360) 417-4815 fax (360) 417-4711 Applicant L 44,'-,c-1 4-JA,,c-'7/o-J Property Owner 8,e4o Coj-,rr 4­z_w4Az, Property Owner's Address 1035 W '7-1", 57 - Contractor Z L*,,jvj iL'oruJ�izcJC 7ivh1 LL C Contractor's Address r:20 RDx / sv License # c &•o-wsc L� 9°(,3 ,2 s Expires /09 .For City Use Only - Date Received ZO - 01 Permit # O - ?S Date Approved o a I - & . Phone Phone A9 4 9.93(, 3 Phone st,o - VS 7 6 2 V7 E-mail /�r✓/�►�E' �i✓�✓LvGJyy �, PROJECT ADDRESS /0039 I,..d 7'1's7 7,2,4 S 3�v3 Parcel Number Lot Zoning R-5,7 Proiect Tvpe & Brief Descriotion. ;'Residential -❑,Multi family ❑. Commercial ❑ Industrial Check all that apply ❑ New Construction A" WA4AYI)-om L fS+ni't-s 4 eh10-rge- boe�roow XAddition 6&.j7�,v4 if -v )hD-,) �( Remodel ❑ Repair Nv KN. -,,U 7,e 3eb�i rac14t�vc,c.%c;��,� ❑ Demolition ❑ Re -roof ❑ House ❑ garage ❑ other ❑ tear off & re -roof ❑ lay over one layer ❑ Heat System ❑ .Heat pump ❑ wood -burning stove ❑ gas fireplace ❑ pellet stove ❑ other ❑ Other Floor Areas Existing (sa. ft.) Proposed (sq. ft.) Basement 7�0 � nCY'e f+.SQ _ r�►'a $ LM l per sq ft. _ $ 15' Floor -leo _ g 47u (Rht",q room�rn� $SS oe 3 9, q60 2nd Floor _ 23 7F u,pctA.im (3eAvwm $S o0 .26 (MI5 3rd Floor h&F- aAAino, -k Garage 0271 Carport Z4L0 0 0- 7 Covered Porch ,Jc-:JeWDeck _ L2$ g�,�nd�locr 12.00 )� 536 - .Cfi t1� adslinq Other -7g0-r1432-tZ4o+4-70 VALUATION $ i 80 000 Total footprint of structures Z%i aTOTTAL sq ft. T Lot size 3 , 1 9 I sq ft. = Lot coverage 3 -7 Site Coverage = the amount of ?mpervious surface on a parcel including structures paved driveways sidewalks patios and otherimpervious(see PAMC 17 94 135 for exemptions) _Site coverage �s/urfaces 6c/J%/N5 jo�,,,ce7ls l W(,�l�7l Ca �.JJ/)C iv+�7iJ[J� C1 .l/��'..i9LJ/J ' J 4 � Max. height of proposed structures '0� ft. Occupancy group # of bedrooms Will a lawn sprinkler system be installed? Occupant load # of full baths Will a fire sprinkler system be installed? Construction type # of half baths /have read and completed this application and know it to be true and correct. I am authorized to apply for this -permit and understand (hat it is my responsibility to determine what permits are required, and to obtain permits priory tow g on projects Date � /��� Print Name /^.1 /2�fs1 /� Signature _ T Forms/Building Divisicn/Bldg Fe mit.doc f \O J