HomeMy WebLinkAbout2004 W 8th St - Building PREPARED 1/24/11 8 27 02 INSPECTION TICKET PAGE 3 CITY OF PORT ANGELES INSPECTOR JAMES LI£RLY DATE 1/24/11 ADDRESS 2004 W 8TH ST SUBDIV TENANT NBR ACE MICHAELS INC CONTRACTOR ACE MICHAELS INC PHONE (360) 460 6172 OWNER ACE MICHAELS INC PHONE (360) 417 9579 PARCEL 06 30 00 9 3 1080 0000 APPL NUMBER 10 00000666 RES NEW SFR REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ME99 01 1/24/11JL MECHANICAL FINAL TIME 01 00 _ January 24 2011 8 19 14 AM 1pangrle MIKE 460 6172 MECHANICAL FINAL AFTERNOON PERMIT PL 00 PLUMBING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS PL2 01 8/24/10 JLL PLUMBING ROUGH IN 8/24/10 AP August 24 2010 8 07 41 AM 1pangrle MARK 808 0174 ROUGH IN PLUMBING August 24 2010 4 25 27 PM jlierly PL6 01 10/08/10 JLL PLUMBING WATER SUPPLY TIME 01 00 10/08/10 AP October 8 2010 8 56 15 AM 1pangrle MIKE 460 6172 WATER LINE AFTERNOON October 8 2010 4 24 27 PM jlierly PL99 01 1/24/11 PLUMBING FINAL TIME 01 00 January 24 2011 8 19 36 AM 1pangrle MIKE 460 6172 PLUMBING FINAL AFTERNOON - COMMENTS AND NOTES PREPARED 1/24/11 8 27 02 INSPECTION TICKET PAGE 2 CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 1/24/11 ADDRESS 2004 W 8TH ST SUBDIV TENANT NBR ACE MICHAELS INC CONTRACTOR ACE MICHAELS INC PHONE (360) 460 6172 OWNER ACE MICHAELS INC PHONE (360) 417 9579 PARCEL 06 30 00 9 3 1080 0000 APPL NUMBER 10 00000666 RES NEW SFR PERMIT BPR 00 BUILDING PERMIT RESIDENTIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS BL1 01 7/19/10 JLL BLDG FOUNDATION FOOTING TIME O1 00 7/19/10 AP July 19 2010 8 24 07 AM 1pangrle MIKE 460 6172 FOUNDATION FOOTING AFTERNOON July 19 2010 4 22 52 PM jlierly BL2 01 7/27/10 JLL BLDG FOUNDATION STEM WALL TIME 09 00 7/27/10 AP July 26 2010 9 12 22 AM 1pangrle MIKE 460 6172 FOUNDATION WALL MORNING THEY PLAN TO POUR AT 11 00 AM TODAY July 27 2010 4 21 07 PM jlierly BLHD O1 9/03/10 JLL BLDG FRAMING HOLD DOWNS 9/03/10 AP September 2 2010 1 23 26 PM 1pangrle MIKE 460 6172 HOLD DOWNS September 3 2010 4 55 30 PM jlierly BL3 01 9/03/10 JLL BLDG FRAMING 9/03/10 AP September 3 2010 8 08 51 AM 1pangrle MIKE 460 6172 FRAMING September 3 2010 4 55 30 PM jlierly BL9 01 9/03/10 JLL BLDG SHEARWALL 9/03/10 AP September 2 2010 1 22 47 PM 1pangrle MIKE 460 6172 EXTERIOR SHEARWALL September 3 2010 4 55 30 PM jlierly BLI O1 9/08/10 JLL BLDG INSULATION 9/08/10 AP September 8 2010 8 22 30 AM 1pangrle MIKE 460 6172 INSULATION (WALLS & CEILING) September 8 2010 4 35 00 PM jlierly 7 BLDR O1 9/16/10 JLL BLDG DRYWALL IBWP 9/16/10 AP September 15 2010 3 34 45 PM 1pangrle MIKE 460 6172 INTERIOR SHEETROCK/SHEAR September 16 2010 4 26 00 PM jlierly BL99 01 1/24/11 L BLDG FINAL TIME O1 00 January 24 2011 8 18 34 AM 1pangrle MIKE 460 6172 .r BUILDING FINAL AFTERNOON PERMIT ME 00 MECHANICAL PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS CONTINUED ONTO NEXT PAGE °F°°"r °� ELECTRICAL INSPECTION WIRING REPORT FRIKS 417-4735 �RKS b DAT PERMIT# INSPECTOR l ,(�o/I OWNER/CONTRACTOR ADDRESS APPROVED NOT APPROVED ❑ DITCH ❑ ❑ ROUGH IN/COVER ❑ ❑. SERVICE ❑ ❑ FINAL �9� CORRECTIONS NEEDED: 6�C 1 Tr?-0'TW-C_-S ALA, 6ylf(ET5 r"V /lN Av4.r wtis NOTIFY INSPECTOR WHEN CORRECTIONS ARE COMPLETED WITHIN 15 DAYS — DO NOT REMOVE — PREPARED 10/08/10 9 04 11 INSPECTION TICKET PAGE 3 CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 10/08/10 ADDRESS 2004 W STH ST SUBDIV TENANT NBR ACE MICHAELS INC CONTRACTOR ACE MICHAELS INC PHONE (360) 460 6172 OWNER ACE MICHAELS INC PHONE (360) 417 9579 PARCEL 06 30 00 9 3 1080 0000 APPL NUMBER 10 00000666 RES NEW SFR PERMIT PL 00 PLUMBING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS PL2 01 8/24/10 JLL PLUMBING ROUGH IN 8/24/10 AP August 24 2010 8 07 41 AM 1pangrle MARK 808 0174 ROUGH IN PLUMBING August 24 2010 4 25 27 PM jlierly PL6 01 10/08/10 JLL PLUMBING WATER SUPPLY TIME O1 00 October 8 2010 8 56 15 AM 1pangrle MIKE 460 6172 t� WATER LINE AFTERNOON COMMENTS AND NOTES PREPARED 9/16/10 8 09 31 INSPECTION TICKET PAGE 6 CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 9/16/10 ADDRESS 2004 W STH ST SUBDIV TENANT NBR ACE MICHAELS INC CONTRACTOR ACE MICHAELS INC PHONE (360) 460 6172 OWNER ACE MICHAELS INC PHONE (360) 417 9579 PARCEL 06 30 00 9 3 1080 0000 APPL NUMBER 10 00000666 RES NEW SFR PERMIT BPR 00 BUILDING PERMIT RESIDENTTAT• REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS BL1 01 7/19/10 JLL BLDG FOUNDATION FOOTING TIME O1 00 7/19/10 AP July 19 2010 8 24 07 AM 1pangrle MIKE 460 6172 FOUNDATION FOOTING AFTERNOON July 19 2010 4 22 52 PM jlierly BL2 01 7/27/10 JLL BLDG FOUNDATION STEM WALL TIME 09 00 7/27/10 AP July 26 2010 9 12 22 AM 1pangrle MIKE 460 6172 FOUNDATION WALL MORNING THEY PLAN TO POUR AT 11 00 AM TODAY July 27 2010 4 21 07 PM jlierly BLHD O1 9/03/10 JLL BLDG FRAMING HOLD DOWNS 9/03/10 AP September 2 2010 1 23 26 PM 1pangrle MIKE 460 6172 'HOLD DOWNS September 3 2010 4 55 30 PM jlierly BL3 01 9/03/10 JLL BLDG FRAMING 9/03/10 AP September 3 2010 8 08 51 AM 1pangrle MIKE 460 6172 FRAMING September 3 2010 4 55 30 PM jlierly BL9 01 9/03/10 JLL BLDG SHEARWALL 9/03/10 AP September 2 2010 1 22 47 PM 1pangrle MIKE 460 6172 EXTERIOR SHEARWALL September 3 2010 4 55 30 PM jlierly BLI O1 9/08/10 JLL BLDG INSULATION 9/08/10 AP September 8 2010 8 22 30 AM 1pangrle MIKE 460 6172 INSULATION (WALLS & CEILING) September 8 2010 4 35 00 PM jlierly BLDR O1 9/1610J BLDG DRYWALL IBWP 0 September 15 2010 3 34 45 PM 1pangrle -� MIKE 460 6172 INTERIOR SHEETROCK/SHEAR COMMENTS AND NOTES PREPARED 9/08/10 8 23 40 INSPECTION TICKET PAGE 7 CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 9/08/10 ADDRESS 2004 W STH ST SUBDIV TENANT NBR ACE MICHAELS INC CONTRACTOR ACE MICHAELS INC PHONE (360) 460 6172 OWNER ACE MICHAELS INC PHONE (360) 417 9579 PARCEL 06 30 00 9 3 1080 0000 APPL NUMBER 10 00000666 RES NEW SFR PERMIT BPR 00 BUILDING PERMIT RESIDENTIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS BL1 01 7/19/10 JLL BLDG FOUNDATION FOOTING TIME 01 00 7/19/10 AP July 19 2010 8 24 07 AM 1pangrle MIKE 460 6172 FOUNDATION FOOTING AFTERNOON July 19 2010 4 22 52 PM jlierly BL2 01 7/27/10 JLL BLDG FOUNDATION STEM WALL TIME 09 00 7/27/10 AP July 26 2010 9 12 22 AM 1pangrle MIKE 460 6172 FOUNDATION WALL MORNING THEY PLAN TO POUR AT 11 00 AM TODAY July 27 2010 4 21 07 PM jlierly BLHD 01 9/03/10 JLL BLDG FRAMING HOLD DOWNS 9/03/10 AP September 2 2010 1 23 26 PM 1pangrle MIKE 460 6172 'HOLD DOWNS September 3 2010 4 55 30 PM jlierly BL3 01 9/03/10 JLL BLDG FRAMING 9/03/10 AP September 3 2010 8 08 51 AM 1pangrle MIKE 460 6172 FRAMING September 3 2010 4 55 30 PM jlierly BL9 01 9/03/10 JLL BLDG SHEARWALL 9/03/10 AP September 2 2010 1 22 47 PM 1pangrle MIKE 460 6172 EXTERIOR SHEARWALL September 3 2010 4 55 30 PM jlierly BLI 01 9/08/10 BLDG INSULATION All September 8 2010 8 22 30 AM 1pangrle MIKE 460 6172 INSULATION (WALLS & CEILING) COMMENTS AND NOTES PREPARED 9/03/10 8 10 12 INSPECTION TICKET PAGE 4 CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 9/03/10 ADDRESS 2004 W 8TH ST SUBDIV TENANT NBR ACE MICHAELS INC CONTRACTOR ACE MICHAELS INC PHONE (360) 460 6172 OWNER ACE MICHAELS INC PHONE (360) 417 9579 PARCEL 06 30 00 9 3 1080 0000 APPL NUMBER 10 00000666 RES NEW SFR PERMIT BPR 00 BUILDING PERMIT RESIDENTIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS BL1 01 7/19/10 JLL BLDG FOUNDATION FOOTING TIME O1 00 7/19/10 AP July 19 2010 8 24 07 AM 1pangrle MIKE 460 6172 FOUNDATION FOOTING AFTERNOON July 19 2010 4 22 52 PM jlierly BL2 01 7/27/10 JLL BLDG FOUNDATION STEM WALL TIME 09 00 7/27/10 AP July 26 2010 9 12 22 AM 1pangrle MIKE 460 6172 FOUNDATION WALL MORNING THEY PLAN TO POUR AT 11 00 AM TODAY July 27 2010 4 21 07 PM jlierly BLHD 01 9/03,/10 BLDG FRAMING HOLD DOWNS % September 2 2010 1 23 26 PM 1pangrle MIKE 460 6172 HOLD DOWNS BL3 01 9/03/10 L BLDG FRAMING ' l September 3 2010 8 08 51 AM 1pangrle MIKE 460 6172 FRAMING BL9 01 9/03/10 JLL BLDG SHEARWALL September 2 2010 1 22 47 PM 1pangrle MIKE 460 6172 EXTERIOR SHEARWALL COMMENTS AND NOTES P't1 5 o�, (ML ENGINEERING S LAND SURVEYING `]' 301 East 6th Street,Suite 1 t�& SSOCIATES Port Angeles,Washmgton 98362 I N C O R P O R A T E D (360)417-0501 Fax(360)417-0514 E-mail:zenovic@olympus.net September 2, 2010 Mr Jim Lierly Building Inspector City of Port Angeles Department of Community Development 41t 321 East Fifth Street Port Angeles, WA 98362 SUBJECT SINGLE FAMILY RESIDENCE, 2004 w 8T" St. Port Angels, WA BPT 10-00000666 Dear Mr Lierly- Upon the request of Ace Michaels Inc, this office has provided an analysis of the gable end wall adjacent to the kitchen and dining room of the residence noted above This wall was built with a flat wall at the 9' plate line and a rake wall up to the ridge The trusses for this are scissor trusses with a bottom chord slope of 2 in 12. This has created a hinge point between the top of the flat 9' wall and the rake wall. There is a scissor truss directly adjacent to the exterior wall providing bracing at the ceiling level To make the wall structurally sound there should be a total of(2)double 2x6 DF#2 studs installed full height in the wall These studs should be located at 8' and 16' from the back of the home The studs should extend from the sole plate to either the bottom chord of the scissor truss or to the bottom of the top plates in the rake wall The existing top plates, in the 9' wall, should be cut to accommodate the installation of the new studs The cut top plates should be attached to the new studs top and bottom and each side with A35 clips. The studs shall be attached at the top and bottom with A35 clips on each side. In addition the studs should be nailed together with 1 OD nails @ 12' o c. staggered Refer to the attached sketch and calculations. If you have any questions, please feel free to contact me. Sincerely Scott eadrick, P E. 2 /G Cc: Ace Mich Inc. wAs w Fc: JN 10227 RF�4365 �SIONAL� OEM,■/11�■1/1►,�■■ ■rn■C!l/L!!/I ■.It■r ■■ a!uL■VL�■■■;i�tz. ijllai air■,■r►iEWAJ�■G■��■■ �■■■ ■■ ■■■■■%■■■ ■� i■■�1■ ■�.ii■i�il��■CIS � . ,� � ��■Gc�iG■r ■■■ No ■■■�i■r■■E�'■■■■ ■ NONE■?■■■■■■■■■■■■■r■r■■■ ■■■■ ■■■■■■■ ■Ivy :I>[lC�iTvT■MEN■nN■■r■■�■�■■■■■■OEM ■....■■■■■-ii ■■■�■i■■r►�ii �-si■m■m■■■■■ ■ ME i■ ■■■■ ■ .yiJillii'�- 7■■■■■■■■ ■ r■ ■din■■■■■■■■■ ■■ ■■�■ i■■m■■■■■■ ■■■■■■n■■■■■ ■■■■ ..�■r■:�■���- � ter■ ■■■■ ■'�i■■r ■■ir ■r■■■■■■■i■ i■■■■■ NEE iii`=� �iiin■ ■■■■■iV1 ■ ON ■ ■■III■■I■11■�ii�r.''i■■ �� ■■■■■ ' ■■ mmI 11■■ ■ �■ ■ I n■Ir■■■■ ■■I■■I■ ■■■■■■■ ■1/1■■■■■■■■■■■ ■■li■I■r■Il�i�� ■■� G:■ ■■ni�i■■■■■r ■11■■�`I■■■■■■■■0 . ■ •No ■■• ■■iG■M0:000i�.. ■ ■ ■ /a■■MM ■■ EM C�..GG■ ■ ■in�■■■■■ ■■�■ ■■ ■■■ ■■■■■ I T � 2 Aa; S' Un -4x�T,4 ( 1)Lop/L T7d th 4o It I i i �Z �f x - I 1 I I I I I 1 I I - I I I I I I _ I _ MECAWind Version 2 0 2 2 per ASCE 7-05 Developed by MECA Enterprises Inc Copyright 2010 www.mecaenterprises com Date 9/2/2010 Project No 10227 Company Name ZENOVIC & ASSOCIATES INC Designed By SRH Address 301 EAST 6TH STREET SUITE 1 Description STR DESING ON GABLE END OF SF City PORT ANGELES Customer Name ACE MICHAELS INC State WA Proj Location 2004 W 8TH STREET PORT ANGEL File Location C \Program Files\MECAWind\Default wnd User Input Data Basic Wind Speed(V) = 100 00 mph Structure Type = Building Structural Category = II Exposure Category = C Natural Frequency = N/A Flexible Structure = No Importance Factor = 1 00 Kd Directional Factor = 0 85 Alpha = 9 50 Zg = 900 00 ft At = 0 11 Bt = 1 00 Am = 0 15 Bm = 0 65 Cc = 0 20 1 = 500 00 ft Epsilon = 0 20 Zmin = 15 00 ft Slope of Roof = 4 12 Slope of Roof(Theta) = 18 42 Deg Ht Mean Roof Ht = 11 42 ft Type of Roof = Gabled RHt Ridge Ht = 13 83 ft Eht Eave Height = 9 00 ft OH Roof Overhang at Eave= 00 ft Roof Area = 764 00 ft^ 2 Bldg Length Along Ridge = 50 00 ft Bldg Width Across Ridge= 29 00 ft Main Wind Force Resisting System(MMS) Figure 6-5 Internal Pressure Coefficients for Buildings, GCpi Enclosed Bldg +GCpi = 0 18 Enclosed Bldg -GCpi = -0 18 Figure 6-6 External Pressure Coefficients Cp - Loads on Main Wind-Force Resisting Systems(Method 2) MWFRS-Wall Pressures Perpendicular to Ridge Wall Cp +GCpi(psf) -GCpi(psf) --------------- ------ ---------- ---------- Leeward Walls -0 50 -11 18 -4 53 Side Walls -0 70 -14 32 -7 67 Elev Kz Kzt qz ----Windward Wall---- Total Shear Moment ft psf +GCpi -GCpi +/-GCpi Kip K-ft ------------------------------------------------------------------------------ 13 83 0 85 1 00 18 47 9 24 15 89 20 41 3 91 7 49 10 00 0 85 1 00 18 47 9 24 15 89 20 41 9 01 27 73 5 00 0 85 1 00 18 47 9 24 15 89 20 41 14 11 63 01 Note 1) Total = Leeward GCPi + Windward GCPi 2) Shear and Moment are sum of forces (Leeward+Windard) acting on bldg Roof Location Cp +GCpi(psf) -GCpi(psf) ----------------------- ------- ---------- ---------- Windward - Min Cp -0 44 -10 23 -3 58 Windward - Max Cp 0 03 -2 85 3 80 Leeward Perp to Ridge -0 57 -12 27 -5 62 Overhang Top (Windward) -0 44 -6 91 -6 91 Overhang Top (Leeward) -0 57 -8 95 -8 95 Overhang (Windward only) 0 80 12 56 12 56 MWFRS-Wall Pressures Parallel to Ridge Wall CP +GCpi(psf) -GCpi(psf) --------------- ------ ---------- ---------- Leeward Walls -0 36 -8 90 -2 25 Side Walls -0 70 -14 32 -7 67 Elev Kz Kzt qz ----Windward Wall---- Total Shear Moment ft psf +GCpi -GCpi +/-GCpi Kip K-ft ------------------------------------------------------------------------------ 13 83 0 85 1 00 18 47 9 24 15 89 18 14 2 01 3 86 10 00 0 85 1 00 18 47 9 24 15 89 18 14 4 64 14 29 5 00 0 85 1 00 18 47 9 24 15 89 18 14 7 27 32 48 Note 1) Total = Leeward GCPi + Windward GCPi 2) Shear and Moment are sum of forces (Leeward+Windard) acting on bldg Roof - Dist from Windward Edge CP +GCpi(psf) -GCpi(psf) --------------------------------- ------ ---------- ---------- 0 0 ft to 5 7 ft -0 90 -17 46 -10 81 5 7 ft to 11 4 ft -0 90 -17 46 -10 81 11 4 ft to 22 8 ft -0 50 -11 18 -4 53 22 8 ft to 50 0 ft -0 30 -8 04 -1 39 Low Rise Bldg Provisions per Fig 6-10 MWFRS Transverse Direction Building GCpf +GCpi -GCpi qh Min P Max P Surface psf psf psf -------- --------- --------- --------- --------- --------- --------- 1 0 52 0 18 -0 18 18 47 6 28 12 93 2 -0 69 0 18 -0 18 18 47 -16 07 -9 42 3 -0 47 0 18 -0 18 18 47 -12 01 -5 36 4 -0 42 0 18 -0 18 18 47 -11 08 -4 43 5 -0 45 0 18 -0 18 18 47 -11 64 -4 99 6 -0 45 0 18 -0 18 18 47 -11 64 -4 99 IE 0 78 0 18 -0 18 18 47 11 08 17 73 2E -1 07 0 18 -0 18 18 47 -23 09 -16 44 3E -0 67 0 18 -0 18 18 47 -15 70 -9 05 4E -0 62 0 18 -0 18 18 47 -14 78 -8 13 1T * * * * 1 57 3 23 2T * * * * -4 02 -2 35 3T * * * * -3 00 -1 34 4T * * * * -2 77 -1 11 Low Rise Bldg Provisions per Fig 6-10 MWFRS Longitudinal Direction Building GCpf +GCpi -GCpi qh Min P Max P Surface psf psf psf -------- --------- --------- --------- --------- --------- --------- 1 0 4 0 18 -0 18 18 47 4 06 10 71 2 -0 69 0 18 -0 18 18 47 -16 07 -9 42 3 -0 37 0 18 -0 18 18 47 -10 16 -3 51 4 -0 29 0 18 -0 18 18 47 -8 68 -2 03 5 -0 45 0 18 -0 18 18 47 -11 64 -4 99 6 -0 45 0 18 -0 18 18 47 -11 64 -4 99 lE 0 61 0 18 -0 18 18 47 7 94 14 59 2E -1 07 0 18 -0 18 18 47 -23 09 -16 44 3E -0 53 0 18 -0 18 18 47 -13 11 -6 46 4E -0 43 0 18 -0 18 18 47 -11 27 -4 62 1T * * * * 1 02 2 68 2T * * * * -4 02 -2 35 3T * * * * -2 54 -0 88 4T * * * * -2 17 -0 51 O ELECTRICAL PERMIT ` a CITY OF PORT ANGELES 360-417-4735 Application Number 10 00000923 Date 8/27/10 Application pin number 206527 Property Address 2004 W 8TH ST REPORT STATE SALES TAX ASSESSOR PARCEL NUMBER 06 30 00 9 3 1080 0000 on your excise tax form Application type description ELECTRICAL ONL Subdivision Name to the City of Port Angeles Property Use (Location Code 0502) Property Zoning RS7 RESDNTL SINGLE FAMILY Application valuation 0 Application desc New home 1400 sqft Owner Contractor ACE MICHAELS INC JEDI ELECTRIC 1329 W 10TH ST 331 FORS RD PORT ANGELES WA 98363 PORT ANGELES WA 98362 (360) 417 9579 (360) 460 0556 Permit ELECTRICAL NEW RESIDENTIAL Additional desc 200 A SVC Permit pin number 172205 Sub Contractor JEDI ELECTRIC Permit Fee 180 70 Plan Check Fee 00 Issue Date 8/27/10 Valuation 0 Expiration Date 2/23/11 Qty Unit Charge Per Extension 1 00 110 3000 ECH EL R SQFT FIRST 1300 110 30 2 00 35 2000 ECH EL R SQFT ADDITIONAL 500 70 40 Fee summary Charged Paid Credited Due / Permit Fee Total 180 70 180 70 00 00 Plan Check Total 00 00 00 00 Grand Total 180 70 180 70 00 00 INSPECTION TYPE DATE. RESULTS INSPECTOR. DITCH 1 SERVICE / L ROUGH IN FINAL 1 271 Lc COMMENTS PERMIT WILL EXPIRE SIX(6)MONTHS FROM LAST INSPECTION Signature of owner or Electrical Contractor X Date: e -- -- --- �f 7z - - Z-E-C).Z EF*9S7cZ 11 4r �70L� W U {?� i�C3RT,i,�,Gl�� ` CITY OF PORT ANGELES PERMIT APPLICATION �� 2Qo� ��� Building Division/Electrical Inspections . 321 East Fifth Street—P O Boa 1150/Port Angeles Washington,95362 ELECTRICAL �l Ph (360)417-4735 Fax: (360)417-4711 INSPECTIONS Date:63;S/ld X 1 &2 Single Family Dwelling _Multi-Family or Commercial` _Commercial Addition/Alteration J Remodel/Repair* *Plan Revie May Be Requires Please Cgmpl%e Electrical Plan Review Information Sheet Job Address: dd .1ee Building Square Footage: Mon Description of above 0 P v i'cta O n PJv ov -e Owner Inf9rmationContractor I formaW� Name: C C v d I Name: &��'C Maiiin A dry s: oy W 811A Sp e e Maili A�dress: O. City o q State:� — City: of O State: w#94 Zip: Phone:640 Fax: Phone: Fax: License tr/Exp. License f'/Exp. C Catgr Bei/ ybo y�7/ Item Unit Charge Total(Qtv Multi lied bv Unit Charge) Service/Feeder 200 Amp. $119-90 $' Service/Feeder 201400 Amp. $145.50 $ Service/Feeder 401-600 Amp $204.60 $ Service/Feeder 601 1000 Amp. $262.20 $ Service/Feeder over 1000 Amp. S 372.50 $ Branch Circuit W/Service Feeder $ 2.60 $ Branch Circuit W/O Service Feeder $ 73.50 $ Each Additional Branch Circuit S 2.60 $ Temp.Service/Feeder 200 Amp. $ 92.70 $ Temp.Service/Feeder 201400 Amp. $110.30 $ Temp.Service/Feeder 401-600 Amp. $148.70 Temp.Service/Feeder 601-1000 Amp $167.90 $ Portal to Portal Hourly $ 95.90 $ Sign/Outline Lighting $ 88.20 $ Signal Circuit/Limited Energy/First 1500 sf-Commercial $ 95.90 $ Note: $5.00 for each additional 1500 sf Signal Circuit/Limited Energy 1 &2 Family Dwelling $ 63.90 $ Signal Circuit/:Limited.Energy Multi-Family Dwelling $ 63.90 $ -Manufactured Home Connection $119.90 $ Renewable Electrical Energy 5KVA System or Less $102.30 $ Thermostat $ 56.00 $ NEW CONSTRUCTION ONLY. First 1300 Square Ft. $110.30 $ 1/0, 30 Each Additional 500 Square Ft.or Portion of $ 35.20 $ Each Outbuilding or Detached Garage $ 73.50 $ Each Swimming Pool or Hot Tub :$110.30 $ / 70 $Total y�� Owner as defined by ROW 19.28.261 (1)Owner will occupy the structure for two years after this electrical permit is finalized. (2)Owner is required to hire an electrical contractor if above said property is fopsale,rent or lease.Permit expires after six months of last inspection. After reading the above.statement, I hereby certify that I am the owner of the above named property or a licensed electrical contractor I am making the electrical installation or alteration incompliance with the electrical laws,N.E.0 ROW Chapter 19.28,WAC Chapter 296-46B,The City of Port Angeles Municipal Code,and Utility Specifications and PAMC 14 05.050 regarding Electrical Permit Applications. Signature of owner electrical contractor or electrical administrator, ❑ cash $ Cheek l ��7T� El Card# k Dated: S/ ��//u 01/0112010 PREPARED 8/24/10 8 10 21 INSPECTION TICKET PAGE 5 CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 8/24/10 ADDRESS 2004 W 8TH ST SUBDIV TENANT NBR ACE MICHAELS INC CONTRACTOR ACE MICHAELS INC PHONE (360) 460 6172 OWNER ACE MICHAELS INC PHONE (360) 417 9579 PARCEL 06 30 00 9 3 1080 0000 APPL NUMBER 10 00000666 RES NEW SFR PERMIT PL 00 PLUMBING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS PL2 01 8/24/'LO J PLUMBING ROUGH IN August 24 2010 8 07 41 AM 1pangrle MARK 808 0174 ROUGH IN PLUMBING COMMENTS AND NOTES PREPARED 7/27/10 8 14 07 INSPECTION TICKET PAGE 6 CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 7/27/10 ADDRESS 2004 W 8TH ST SUBDIV TENANT NBR ACE MICHAELS INC CONTRACTOR ACE MICHAELS INC PHONE (360) 460 6172 OWNER ACE MICHAELS INC PHONE (360) 417 9579 PARCEL 06 30 00 9 3 1080 0000 APPL NUMBER 10 00000666 RES NEW SFR PERMIT BPR 00 BUILDING PERMIT RESIDENTIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS BL1 01 7/19/10 JLL BLDG FOUNDATION FOOTING TIME 01 00 7/19/10 AP July 19 2010 8 24 07 AM 1pangrle MIKE 460 6172 FOUNDATION FOOTING AFTERNOON July 19 2010 4 22 52 PM jlierly BL2 01 7/27/10 L BLDG FOUNDATION STEM WALL TIME 09 00 July 26 2010 9 12 22 AM 1pangrle MIKE 460 6172 FOUNDATION WALL MORNING THEY PLAN TO POUR AT 11 00 AM TODAY COMMENTS AND NOTES \ ^ OO 1 / N CITY OF PORT ANGELES PUBLIC WORKS & UTILITIES 321 EAST 5TH STREET PORT ANGELES, WA 98362 Application Number 10 00000666 Date 7/22/10 Application pin number 312584 Property Address 2004 W 8TH ST REPORT SALES TAX ASSESSOR PARCEL NUMBER 06 30 00 9 3 1080 0000 Tenant nbr name ACE MICHAELS INC on your state excise tax form Application type description RES NEW SFR to the City of Port Angeles Subdivision Name Property Use (Location Code 0502) Property Zoning RS7 RESDNTL SINGLE FAMILY Application valuation 131165 Application desc 1 373 SF SFR 458 SF ATT GARAGE 60 SF CVRD PORCH Owner Contractor ACE MICHAELS INC ACE MICHAELS INC 1329 W 10TH ST 1329 W 10TH ST PORT ANGELES WA 98363 PORT ANGELES WA 98363 (360) 417 9579 (360) 460 6172 Structure Information 000 000 1 373 SF SFR, 458 ATT GAR 60 SF CV PRCH Other struct info TOTAL W LOT COVERAGE 17 56 CONSTRUCTION TYPE VB FIRE SPRINKLERS REQUIRED NO NUMBER OF STORIES 1 00 LOT SIZE 10767 00 PROPOSED LOT COVERAGE 1891 00 TOTAL LOT COVERAGE 1891 00 NUMBER OF UNITS 1 00 Permit SANITARY SEWER HOOK UP Additional desc Permit pin number 169938 Permit Fee 150 00 Plan Check Fee 00 Issue Date 7/22/10 Valuation 131165 Expiration Date 1/18/11 Qty Unit Charge Per Extension 1 00 150 0000 EA SAN SEWER HOOKUP 150 00 Special Notes and Comments 09 July 1 2010 10 36 25 AM rbecker The place on the application about sprinkler systems never got filled out Are you installing a lawn sprinkler system If you are you will need to install a double check valve assembly Are you installing a fire system If it is a closed system you will need to install a double check valve assembly If it is an open system you will not need to install a backflow assembly If you have any questions call Ron Becker at 417 4886 or E mail me at rbecker@cityofpa us or Fax 360 452 4972 Address numbers shall be plainly visible from the street Address numbers shall be a minimum of six inches high and be Separate Permits are required for electrical work,SEPA,Shoreline ESA,utilities private and public improvements This permit becomes null and void if work or construction authorized is not commenced within 180 days if construction or work is suspended or abandoned for a period of 180 days after the work as�commenced,or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. Signa re of Contractor or Authorized Agent Date Signature of Owner(if owner is builder) Date T\Policies\1102.15[10/08] PERMIT INSPECTION RECORD T. CALL 417-4831 FOR UTILITY INSPECTIONS PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT INA CONSPICUOUS LOCATION r KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE INSPECTION TYPE DATE ACCEPTED COMMENTS YES NO PW UTILITIES (Engineering Division) WATERLINE/METER SEWER CONNECTION SANITARY STORM SITE DRAINAGE SITE EROSION CONTROL PARKING SIDEWALK CURB&GUTTER DRIVEWAY APPROACH BACK-FLOW DEVICE FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE RESIDENTIAL DATE YES NO COMMERCIAL DATE ACCEPTED YES NO CONSTRUCTION R.W /PW/ CONSTRUCTION R.W ENGINEERING 417-4831 PW/ENGINEERING FIRE 417-4653 FIRE DEPT PLANNING DEPT 417-4750 PLANNING DEPT BUILDING 417-4815 BUILDING T\Policies\1102 15[10/081 CITY OF PORT ANGELES PUBLIC WORKS & UTILITIES 321 EAST 5TH STREET PORT ANGELES,WA 98362 Page 2 Application Number 10 00000666 Date 7/22/10 Application pin number 312584 REPORT SALES TAX Special Notes and Comments on your state excise tax form of contrasting color from the background to the City of Port Angeles A residential fire sprinkler system installed per NFPA (Location Code 0502) 13D will be required 2nd option is to install an outside alarm bell that is inter connected to the residence s smoke detectors The alarm bell will be painted red in color and identified as Fire alarm July 13 2010 3 57 14 PM sroberds The proposal will result in a new sfr in the RS 9 with resulting lot coverage of 18t and 23t site coverage No land use issues anticipated July 1 2010 9 00 58 AM Brian 417 4708 Underground service ok $770 connection fee Electrical load calculations and electrical permits are required Sanitary sewer connection inspection is required by Public Works prior to back fill of ditch 24 hour advance notice is required Asphalt restoration to be completed by owner at the owners expense Construct driveway to City Standards Concrete with exposed aggregate or other non standard finishes(including colors or dyes)are not allowed in the City road right of way Broom finish only An inspection by Public Works Engineering is required prior to pouring concrete Other Fees RES UNDERGRND SERVICE FEE 770 00 SEWER SYSTEM DELV CHARGE 1980 00 STATE SURCHARGE 4 50 PW WATER SYSTEM USE FEE 1980 00 Fee summary Charged Paid Credited Due Permit Fee Total 150 00 150 00 00 00 Plan Check Total 00 00 00 00 Other Fee Total 4734 50 4734 50 00 00 Grand Total 4884 50 4884 50 00 00 Separate Permits are required for electrical work,SEPA,Shoreline ESA,utilities private and public improvements This permit becomes null and void if work or construction authorized is not commenced within 180 days if construction or work is suspended or abandoned for a period of 180 days after the work as.commenced,or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. Signature of Contractor or Authorized Agent Date Signature of Owner(if owner is builder) Date T\Policies\1102.15[10/08) PERMIT INSPECTION RECORD CALL 417-4831 FOR UTILITY INSPECTIONS PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. ITIS UNLAWFUL TO COVER, ' INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT INA CONSPICUOUS LOCATION , KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE INSPECTION TYPE DATE ACCEPTED COMMENTS YES NO PW UTILITIES (Engineering Division) WATERLINE/METER SEWER CONNECTION SANITARY STORM SITE DRAINAGE SITE EROSION CONTROL PARKING SIDEWALK CURB&GUTTER DRIVEWAY APPROACH BACK-FLOW DEVICE FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE RESIDENTIAL DATE YES NO COMMERCIAL DATE ACCEPTED YES NO CONSTRUCTION R.W /PW/ CONSTRUCTION R.W ENGINEERING 417-4831 PW/ENGINEERING FIRE 417-4653 FIRE DEPT PLANNING DEPT 417-4750 PLANNING DEPT BUILDING 417-4815 BUILDING T\Policies\1102 15[10/08] wF� CITY OF PORT ANGELES PUBLIC WORKS & UTILITIES 321 EAST 5TH STREET PORT ANGELES, WA 98362 Application Number 10 00000753 Date 7/21/10 Application pin number 535689 Property Address 2004 W 8TH ST REPORT SALES TAX ASSESSOR PARCEL NUMBER 06 30 00 9 3 1080 0000 on your state excise tax form Application type description PUBLIC WORKS UTILITES Y Subdivision Name to the City of Port Angeles Property Use (Location Code 0502) Property Zoning RS7 RESDNTL SINGLE FAMILY Application valuation 0 Application desc RCP# 10 23 Owner Contractor ACE MICHAELS INC OWNER 1329 W 10TH ST PORT ANGELES WA 98363 (360) 417 9579 Permit RIGHT OF WAY Additional desc FEES PAID PER PERMIT #10 666 Permit pin number 169946 Permit Fee 00 Plan Check Fee 00 Issue Date 7/21/10 Valuation 0 Expiration Date 1/17/11 Special Notes and Comments Tranches over 4 feet in depth to be shored in accordance with State and Federal laws Backfill in paved area s to CDF Fee summary Charged Paid Credited Due Permit Fee Total 00 00 00 00 Plan Check Total 00 00 00 00 Grand Total 00 00 00 00 _ 1N Separate Permits are required for electrical work,SEPA,Shoreline ESA,utilities private and public improvements This permit becomes null and void if work or construction authorized is not commenced within 180 days if construction or work is suspended or abandoned for a period of 180 days after the work as-commenced,or if required inspections have not been requested within 180 days from the last inspection I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. AA I KJ-q-Q Sign ure of Contractor or Authorized Agent Date Signature of Owner(if owner is builder) Date T\Policies\1102.15[10/08] PERMIT INSPECTION RECORD CALL 417-4831 FOR UTILITY INSPECTIONS PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. ITIS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT INA CONSPICUOUS LOCATION KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE INSPECTION TYPE DATE ACCEPTED COMMENTS YES NO PW UTILITIES (Engineering Division) WATERLINE/METER SEWER CONNECTION SANITARY STORM SITE DRAINAGE SITE EROSION CONTROL PARKING SIDEWALK CURB&GUTTER DRIVEWAY APPROACH BACK-FLOW DEVICE FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE RESIDENTIAL DATE YES NO COMMERCIAL DATE ACCEPTED YES NO CONSTRUCTION R.W /PW/ CONSTRUCTION R.W ENGINEERING 417-4831 PW/ENGINEERING FIRE 417-4653 FIRE DEPT PLANNING DEPT 417-4750 PLANNING DEPT BUILDING 417-4815 BUILDING T\Policies\1 102 15[10/08] PREPARED 7/19/10 8 25 06 INSPECTION TICKET PAGE 6 CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 7/19/10 ADDRESS 2004 W STH ST SUBDIV TENANT NBR ACE MICHAELS INC CONTRACTOR ACE MICHAELS INC PHONE (360) 460 6172 OWNER ACE MICHAELS INC PHONE (360) 417 9579 PARCEL 06 30 00 9 3 1080 0000 APPL NUMBER 10 00000666 RES NEW SFR PERMIT BPR 00 BUILDING PERMIT RESIDENTIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS BL1 01 7/19/10 JLL BLDG FOUNDATION FOOTING TIME O1 00 July 19 2010 8 24 07 AM 1pangrle MIKE 460 6172 FOUNDATION FOOTING AFTERNOON COMMENTS AND NOTES 1' CITY OF PORT ANGELES DEPARTMENT OF COMMUNITY & ECONOMIC DEVELOPMENT BUILDING DIVISION 321 EAST 5TH STREET PORT ANGELES WA 98362 w Application Number 10 00000666 Date 7/13/10 Application pin number 312584 Property Address 2004 W 8TH ST REPORT SALES TAX ASSESSOR PARCEL NUMBER 06 30 00 9 3 1080 0000 on your state excise tax form Tenant nbr name ACE MICHAELS INC Application type description RES NEW SFR to the City of Port Angeles Subdivision Name (Location Code 0502) Property Use Property Zoning RS7 RESDNTL SINGLE FAMILY Application valuation 131165 Application desc 1 373 SF SFR 458 SF ATT GARAGE 60 SF CVRD PORCH Owner Contractor ACE MICHAELS INC ACE MICHAELS INC 1329 W 10TH ST 1329 W 10TH ST PORT ANGELES WA 98363 PORT ANGELES WA 98363 (360) 417 9579 (360) 460 6172 Structure Information 000 000 1 373 SF SFR 458 ATT GAR 60 SF CV PRCH Other struct info TOTAL % LOT COVERAGE 17 56 CONSTRUCTION TYPE VB FIRE SPRINKLERS REQUIRED NO NUMBER OF STORIES 1 00 LOT SIZE 10767 00 PROPOSED LOT COVERAGE 1891 00 TOTAL LOT COVERAGE 1891 00 NUMBER OF UNITS 1 00 Permit BUILDING PERMIT RESIDENTIAL Additional desc 1 373 SF SFR 458 SF GARAGE Permit pin number 168336 Permit Fee 1199 45 Plan Check Fee 779 64 Issue Date 7/13/10 Valuation 131165 Expiration Date 1/09/11 n Qty Unit Charge Per Extension n, BASE FEE 1020 25 32 00 5 6000 THOU BL-100 001 500K (5 60 PER K) 179 20 Permit MECHANICAL PERMIT 0\A; Additional Additional desc vv Permit pin number 168468 Permit Fee 208 05 Plan Check Fee 00 Issue Date 7/13/10 Valuation 0 Expiration Date 1/09/11 Qty Unit Charge Per Extension BASE FEE 50 00 4 00 7 2500 EA ME VENT FAN (SINGLE DUCT) 29 00 1 00 10 6500 EA ME STOVE/FIREPLACE/.MISC APP 10 65 8 00 14 8000 EA ME HEATER(SUSP/WALL/FLOOR MTD) 118 40 Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned fora period of 180 days after the work has commenced,or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulatingsconstruction or the performance of constr ction. -AILS Date Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is uilder) T:Forms/Building Division/Building Permit BUILDING PERMIT INSPECTION RECORD -- PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS-- Building Inspections 417-4815 Electrical Inspections 417-4735 Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886 IT IS UNLAWFUL TO COVER,INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED POST PERMIT IN CONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE. Inspection Type Date Accepted By Comments FOUNDATION- Footings OUNDATION•Footin s Stemwall Foundation Drainage/Downspouts Piers Post Holes(Pole Bldgs) PLUMBING Under Floor/Slab Rough-In Water Line(Meter to Bldg) Gas Line Back Flow/Water FINAL Date Accepted b AIR SEAL. Walls Ceiling FRAMING Joists/Girders/Under Floor Shear Wall/Hold Downs Walls/Roof/Ceiling Drywall Interior Braced Panel Only) T-Bar INSULATION Slab Wall/Floor/Ceiling MECHANICAL. Heat Pum /Furnace/FAU/Ducts Rough-in Gas Line Wood Stove/Pellet/Chimney Commercial Hood/Ducts FINAL Date Accepted b MANUFACTURED HOMES Footing/Slab Blocking&Hold Downs Skirting PLANNING DEPT Separate Permit#s SEPA. Parkin /Lighting ESA. Landscaping SHORELINE. FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE Inspection Type Date Accepted By Electrical 417-4735 Construction R.W PW I Engineering 417-4831 Fire 417-4653 Planning 417-4750 Building 417-4815 T.Forms/Building Division/Building Permit CITY OF PORT ANGELES DEPARTMENT OF COMMUNITY &ECONOMIC DEVELOPMENT-BUILDING DIVISION 321 EAST 5TH STREET PORT ANGELES,WA 98362 R Page 2 Application Number 10 00000666 Date 7/13/10 Application pin number 312584 REPORT SALES TAX Permit PLUMBING PERMIT Additional desc on your state excise tax form Permit pin number 168476 to the City of Port Angeles Permit Fee 156 00 Plan Check Fee 00 (Location Code 0502) Issue Date 7/13/10 Valuation 0 Expiration Date 1/09/11 Qty Unit Charge Per Extension BASE FEE 50 00 11 00 7 0000 EA PL-PLUMBING TRAP 77 00 1 00 7 0000 EA PL-WATER LINE 7 00 1 00 15 0000 EA PL-SEWER LINE 15 00 1 00 7 0000 EA PL-WATER HEATER 7 00 Special Notes and Comments July 1 2010 10 36 25 AM rbecker The place on the application about sprinkler systems never got filled out Are you installing a lawn sprinkler system If you are you will need to install a double check valve assembly Are you installing a fire system If it is a closed system you will need to install a double check valve assembly If it is an open system you will not need to install a backflow assembly If you have any questions call Ron Becker at 417 4886 or E mail me at rbecker@cityofpa us or Fax 360 452 4972 Address numbers shall be plainly visible from the street Address numbers shall be a minimum of six inches high and be of contrasting color from the background A residential fire sprinkler system installed per NFPA 13D will be required 2nd option is to install an outside alarm bell that is inter connected to the residence s smoke detectors The alarm bell will be painted red in color and identified as Fire alarm July 13 2010 3 57 14 PM sroberds The proposal will result in a new sfr in the RS 'I with resulting lot coverage of 18t and 23t site coverage No land use issues anticipated July 1 2010 9 00 58 AM Brian 417 4708 Underground service ok $770 connection fee Electrical load calculations and electrical permits are required Sanitary sewer connection inspection is required by Public Works prior to back fill of ditch 24 hour advance notice is required Asphalt restoration to be completed by owner at the owners expense Construct driveway to City Standards Concrete with exposed aggregate or other non standard finishes(including colors or dyes)are not allowed in the City road right of way Broom finish only An inspection by Public works Engineering is required prior to pouring concrete Separate Permits are required for electrical work, SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned for a period of 180 days after the work has commenced,or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. Date Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is builder) T:FonnsBuilding Division/Building Pennit a BUILDING PERMIT INSPECTION RECORD -- PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS-- Building Inspections 417-4815 Electrical Inspections 417-4735 Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886 IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE. Inspection Type Date Accepted By Comments FOUNDATION Footings Stemwall Foundation Drainage/Downspouts Piers Post Holes(Pole Bldgs.) PLUMBING Under Floor/Slab Rough-In Water Line(Meter to Bldg) Gas Line Back Flow/Water FINAL Date Accepted b AIR SEAL. Walls Ceiling FRAMING Joists/Girders/Under Floor Shear Wall/Hold Downs Walls/Roof/Ceiling Drywall Interior Braced Panel Only) T-Bar INSULATION. Slab Wall/Floor/Ceiling MECHANICAL. Heat Pum /Furnace/FAU/Ducts Rough-In Gas Line Wood Stove/Pellet/Chimney Commercial Hood/Ducts FINAL Date Accepted b MANUFACTURED HOMES Footing/Slab Blocking&Hold Downs Skirting PLANNING DEPT Separate Permit#s SEPA. Parkin /Lighting ESA. Landscaping SHORELINE. FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE Inspection Type Date Accepted By Electrical 417-4735 Construction R.W PW I Engineering 417-4831 Fire 417-4653 Planning 417-4750 Building 417-4815 T Forms/Building Division/Building Permit CITY OF PORT ANGELES "moi. DEPARTMENT OF COMMUNITY & ECONOMIC DEVELOPMENT BUILDING DIVISION Co 321 EAST 5TH STREET PORT ANGELES, WA 98362 w Page 3 Application Number 10 00000666 Date 7/13/10 Application pin number 312584 REPORT SALES TAX Other Fees RES UNDERGRND SERVICE FEE 770 00 on your state excise tax form SEWER SYSTEM DELV CHARGE 1980 00 to the City of Port Angeles STATE SURCHARGE 4 50 (Location Code 0502) PW WATER SYSTEM USE FEE 1980 00 Fee summary Charged Paid Credited Due Permit Fee Total 1563 50 1563 50 00 00 Plan Check Total 779 64 779 64 00 00 Other Fee Total 4734 50 4734 50 00 00 Grand Total 7077 64 7077 64 00 00 Separate Permits are required for electrical work,SEPA,Shoreline,ESA,utilities,private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned for a period of 180 days after the work has commenced,or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. Date Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is builder) T:Fonns/Building Division/Building Pennit a BUILDING PERMIT INSPECTION RECORD O -- PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS– Building Inspections 417-4815 Electrical Inspections 417-4735 Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886 61 IT IS UNLAWFUL TO COVER,INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED POST PERMIT INCONSPICUOUS LOCATION KEEP PERMIT AND APPROVED PLANS AT JOB SITE. �V. Inspection Type Date Accepted By Comments FOUNDATION- Footings OUNDATION•Footin s – 10 L Stemwall I Foundation Drainage/Downspouts Piers Post Holes(Pole Bldgs.) PLUMBING Under Floor/Slab Rou h-Inv — 0 L Water Line Meter to Bldg) � V Gas Line ���� Back Flow/Water FINAL Date©,'2 Accepted b AIR SEAL. —?j 710 �C_ Walls Ceiling FRAMING Joists/Girders/Under Floor Shear Wall Hold Downs — — 10 Walls/Roof/Ceiling— Drywall eilinD all(Interior Braced Panel Onl co T-Bar INSULATION. Slab Wall/Floor/Ceiling MECHANICAL. V ` Heat Pum /Furnace/FAU/Ducts Rough-in Gas Line Wood Stove/Pellet/Chimney Commercial Hood/Ducts FINAL Date Accepted by 1�- MANUFACTURED HOMES Footing/Slab Blocking&Hold Downs Skirting PLANNING DEPT Separate Permit#s SEPA. Parkin /Lighting ESA. Landscaping SHORELINE. FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE Inspection Type Date Accepted By Electrical 417-4735 Construction R.W PW /Engineering 417-4831 Fire 417-4653 Planning 417-4750 1 t u (n Building 417-4815 T:Forms/Building Division/Building Permit of ^FN CITY OF PORT ANGELES PUBLIC WORKS & UTILITIES s—v 321 EAST 5TH STREET PORT ANGELES, WA 98362 Application Number 10 00000666 Date 7/13/10 Application pin number 312584 Property Address 2004 W 8TH ST REPORT SALES TAX ASSESSOR PARCEL NUMBER 06 30 00 9 3 1080 0000 Tenant nbr name ACE MICHAELS INC on your state excise tax form Application type description RES NEW SFR to the City of Port Angeles Subdivision Name (Location Code 0502) Property Use Property Zoning RS7 RESDNTL SINGLE FAMILY Application valuation 131165 Application desc 1 373 SF SFR 458 SF ATT GARAGE 60 SF CVRD PORCH Owner Contractor ACE MICHAELS INC ACE MICHAELS INC 1329 W 10TH ST 1329 W 10TH ST PORT ANGELES WA 98363 PORT ANGELES WA 98363 (360) 417 9579 (360) 460 6172 Structure Information 000 000 1 373 SF SFR 458 ATT GAR 60 SF CV PRCH Other struct info TOTAL %, LOT COVERAGE 17 56 CONSTRUCTION TYPE VB FIRE SPRINKLERS REQUIRED NO NUMBER OF STORIES 1 00 LOT SIZE 10767 00 PROPOSED LOT COVERAGE 1891 00 TOTAL LOT COVERAGE 1891 00 NUMBER OF UNITS 1 00 Permit DRIVEWAY INSTALLATION �,( Additional desc C�i Permit pin number 169367 14- Permit Fee 180 00 Plan Check Fee 00 Issue Date 7/13/10 Valuation 0 Expiration Date 1/09/11 Qty Unit Charge Per Extension BASE FEE 180 00 Permit PUBLIC WORKS RES WATER SERV OQ Additional desc Permit pin number 169375 Permit Fee 1160 00 Plan Check Fee 00 Issue Date 7/13/10 Valuation 131165 Expiration Date 1/09/11 Qty Unit Charge Per Extension 1 00 1160 0000 EA PW W/M 1 SERV 5/8 METER 1160 00 Permit RIGHT OF WAY Additional desc Permit pin number 169383 Permit Fee 150 00 Plan Check Fee 00 Separate Permits are required for electrical work,SEPA,Shoreline ESA,utilities private and public improvements This permit becomes null and void if work or construction authorized is not commenced within 180 days if construction or work is suspended or abandoned for a period of 180 days after the work as commenced,or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction -, �. Signature of rontractor or Authorized Agent Date Signature of Owner(if owner is builder) Date T'\Policies\1102 15[10/08] PERMIT INSPECTION RECORD CALL 417-4831 FOR UTILITY INSPECTIONS PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE ITIS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED POST PERMIT INA CONSPICUOUS LOCATION KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE INSPECTION TYPE DATE ACCEPTED COMMENTS YES NO PW UTILITIES (Engineering Division) WATERLINE/METER SEWER CONNECTION SANITARY STORM SITE DRAINAGE- SITE EROSION CONTROL PARKING SIDEWALK CURB&GUTTER DRIVEWAY APPROACH BACK-FLOW DEVICE FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE RESIDENTIAL DATE YES NO COMMERCIAL DATE ACCEPTED YES NO CONSTRUCTION R.W IPWI CONSTRUCTION R.W ENGINEERING 417-4831 PW/ENGINEERING FIRE 417-4653 FIRE DEPT PLANNING DEPT 417-4750 PLANNING DEPT BUILDING 417-4815 BUILDING T ,Policies\l102 1 [10/08] CITY OF PORT ANGELES PUBLIC WORKS & UTILITIES 321 EAST 5TH STREET PORT ANGELES WA 98362 Page 2 Application Number 10 00000666 Date 7/13/10 Application pin number 312584 REPORT SALES TAX Issue Date 7/13/10 Valuation 131165 Expiration Date 1/09/11 on your state excise tax form to the City of Port Angeles Qty Unit Charge Per Extension (Location Code 0502) 1 00 150 0000 ECH PW RW CONST EXCAVTION OTHER 150 00 Special Notes and Comments July 1 2010 10 36 25 AM rbecker The place on the application about sprinkler systems never got filled out Are you installing a lawn sprinkler system If you are you will need to install a double check valve assembly Are you installing a fire system If it is a closed system you will need to install a double check valve assembly If it is an open system you will not need to install a backflow assembly If you have any questions call Ron Becker at 417 4886 or E mail me at rbecker@cityofpa us or Fax 360 452 4972 Address numbers shall be plainly visible from the street Address numbers shall be a minimum of six inches high and be of contrasting color from the background A residential fire sprinkler system installed per NFPA 13D will be required 2nd option is to install an outside alarm bell that is inter connected to the residence s smoke detectors The alarm bell will be painted red in color and identified as Fire alarm July 13 2010 3 57 14 PM sroberds The proposal will result in a new sfr in the RS 9 with resulting lot coverage of 18% and 23%1 site coverage No land use issues anticipated July 1 2010 9 00 58 AM Brian 417 4708 Underground service ok $770 connection fee Electrical load calculations and electrical permits are required Sanitary sewer connection inspection is required by Public Works prior to back fill of ditch 24 hour advance notice is required Asphalt restoration to be completed by owner at the owners expense Construct driveway to City Standards Concrete with exposed aggregate or other non standard finishes(including colors or dyes)are not allowed in the City road right of way Broom finish only An inspection by Public Works Engineering is required prior to pouring concrete Other Fees RES UNDERGRND SERVICE FEE 770 00 SEWER SYSTEM DELV CHARGE 1980 00 STATE SURCHARGE 4 50 PW WATER SYSTEM USE FEE 1980 00 Fee summary Charged Paid Credited Due Separate Permits are required for electrical work,SEPA,Shoreline ESA,utilities private and public improvements This permit becomes null and void if work or construction authorized is not commenced within 180 days if construction or work is suspended or abandoned for a period of 180 days after the work as commenced,or if required inspections have not been requested within 180 days from the last inspection I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction Signature of Contractor or Authorized Agent Date Signature of Owner(if owner is builder) Date T'\Policies\1102 15[10/08] PERMIT INSPECTION RECORD CALL 417-4831 FOR UTILITY INSPECTIONS PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL 4NY WORK BEFORE INSPECTED AND ACCEPTED POST PERMIT INA CONSPICUOUS LOCATION KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE INSPECTION TYPE DATE ACCEPTED COMMENTS YES NO PW UTILITIES (Engineering Division) WATERLINE/METER SEWER CONNECTION SANITARY STORM SITE DRAINAGE SITE EROSION CONTROL PARKING SIDEWALK CURB&GUTTER DRIVEWAY APPROACH BACK-FLOW DEVICE u FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE RESIDENTIAL DATE YES NO COMMERCIAL DATE ACCEPTED NES NO CONSTRUCTION R.W /PW/ CONSTRUCTION R.W ENGINEERING 417-4831 PW/ENGINEERING FIRE 417-4653 FIRE DEPT PLANNING DEPT 417-4750 PLANNING DEPT BUILDING 417-4815 BUILDING T\Policies\110' 1 [10/081 OF 90R',,',C CITY OF PORT ANGELES PUBLIC WORKS & UTILITIES 321 EAST 5TH STREET PORT ANGELES, WA 98362 Page 3 Application Number 10 00000666 Date 7/13/10 Application pin number 312584 REPORT SALES TAX Permit Fee Total 1490 00 1490 00 00 00 on our state excise tax form Plan Check Total 00 00 00 00 Y Other Fee Total 4734 50 4734 50 00 00 to the City of Port Angeles Grand Total 6224 50 6224 50 00 00 (Location Code 0502) Separate Permits are required for electrical work,SEPA,Shoreline ESA,utilities private and public improvements This permit becomes null and void if work or construction authorized is not commenced within 180 days if construction or work is suspended or abandoned for a period of 180 days after the work as commenced,or if required inspections have not been requested within 180 days from the last inspection I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction Signature of Contractor or Authorized Agent Date Signature of Owner(if owner is builder) Date T\Policies\1102 13[10/08] PERMIT INSPECTION RECORD CALL 417-4831 FOR UTILITY INSPECTIONS PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE ITIS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT INA CONSPICUOUS LOCATION KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE INSPECTION TYPE DATE ACCEPTED COMMENTS YES NO PW UTILITIES (Engineering Division) WATERLINE/METER SEWER CONNECTION SANITARY STORM SITE DRAINAGE SITE EROSION CONTROL PARKING SIDEWALK CURB&GUTTER DRIVEWAY APPROACH BACK-FLOW DEVICE FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCV/USE RESIDENTIAL DATE YES NO COMMERCIAL DATE ACCEPTED YES NO CONSTRUCTION R.W /PW/ CONSTRUCTION R.W ENGINEERING 417-4831 PW i ENGINEERING FIRE 417-4653 FIRE DEPT PLANNING DEPT 417-4750 PLANNING DEPT BUILDING 417-4815 BUILDING T\Policies\1102 15[10/08] RESIDENTIAL PLAN REVIEW GUIDELINES Oc FORT ANclf City of Port Angeles s Building Division 321 E 5th St. FILE -- - Port Angeles, WA 98362 PLAN REVIEW Items described here are only a guide to common questions and missed items during plan review and construction All codes must be complied with (Please read and follow each item ) SPECIAL NOTE. Check item #59 first to see if engineerinq will be needed because of lateral design issues. GENERAL. 1 Final grading of the property must be done prior to final inspection even if owner is doing required retaining walls Occupancy of the home will not be allowed until there are no slopes steeper than 2 units horizontal to 1 unit vertical or retaining walls are in place or an accepted soils report is submitted to the City If a soils report was required initially all requirements of the soils report must be accomplished prior to final inspection including submittal of all field reports. 2. Acrylic stucco products have special requirements Verify such with the manufacturer Requirements may include tongue and groove foam board under finish control joints special backing boards (sometimes OSB is NOT allowed) self-furring or furred-out wire or fabric lath and sometimes installation by a certified installer (certified by the manufacturer) Verify any and all requirements of stucco siding or acrylic stucco products NO INSPECTION OF LATH OR STUCCO IS REQUIRED, BUT WRITTEN CERTIFICATION BY A MANUFACTURER'S CERTIFIED INSTALLER MUST BE LEFT AT THE JOB SITE UNTIL FINAL INSPECTION BY THE CITY 3 Inspection of shear wall nailing roof sheathing to blocking nailing and hold downs must be requested in addition to standard inspections and before such items are covered up Please specify shear nail roof nail or hold-down inspection when you request these they may be done simultaneously if ready 4 This plan is approved for OSB or plywood exterior wall sheathing only unless the approved plans at the time of permit issuance reflect other materials being used Any change to wall sheathing material after permit issuance must be submitted to the city for review prior to installation An additional plan review fee will be assessed 5. 'Tyvek' or equal approved weather resistive barrier (15# felt is OK) required on the exterior side of all walls regardless of the type of siding used This includes garage walls gable portion of end walls and cripple walls (at stepped foundation conditions) Apply over exterior sheathing or over studs in-single-wall construction T-1-11 or similar panel siding must have 'Tyvek' or equal over the studs. 6 Exterior windows and doors shall be flashed with approved materials and caulking Caulked trim material over the window or door flange is not an acceptable method. 7 Overall dimensions of house plan must match site plan dimensions Verify any special requirements for buildings located close to property lines R302 T Building/Handouts/Residential Plan Review Guidelines (Rev 03-18-09) Page 1 of 8 LIFE-SAFETY & MISC ITEMS 8. Sleeping rooms must have an egress window with 5 7 s f net clear opening 24" min height, 20" min. width 44" maximum from floor to window sill Windows must meet all 4 dimensions R310 1 9 Safety or tempered glass shall be used in windows that are (R308 4) Adjacent to a door (24 arc of either edge of the door in a closed position) • That are closer than 18" to floor (AND individual.pane is more than 9 s f top edge more than 36' a.f f and walking surface within 36" horizontally of the window in question) • Walls enclosing a tub or shower (AND within 60' of the drain or within 60" of walking surface) R308 4 • Adjacent to stairways landings and ramps within 36" horizontally of a walking surface (AND less than 60' a f f of the walking surface) • Adjacent to stairways within 60" of the bottom tread of the stair in any direction (AND less than 60" a f f) 10 Under-stair areas that are enclosed and accessible must be sheetrocked 1/2" GWB on walls and underside of the stairway R311 2.2 11 Stairways shall have 10' min tread and 7 3/4" max. rise R311 5 12. Provide 36' high guards (with 4 max. spacing on rails) at porches balconies and raised floor surfaces more than 30' above adjacent ground or floor R312 1 13 Smoke detectors required at all bedrooms hallway or room adjacent to bedrooms and at any ceilings that are more than 24 above adjacent ceiling All smoke detectors interconnected and hardwired with battery back-up R3131 14 Garage/house separation wall is 1/2' GWB door must be 20 min rated or 1 3/8' soiid-core If living space above use 5/8 GWB Type "X" at the ceiling AND 1/2' GWB at walls that support the floor above Ducts in garage must be 26-gage sheet steel and have no openings in the garage R309 15 Exterior stairways must have a light located near the top landing of the stairway switched from inside (or have motion-activation device) R303 6 16. Minimum room areas must be provided (120 s f min in at least one room 70 s f min all other habitable rooms 7 foot min dimension in all habitable rooms) R304 1 17 Minimum ceiling heights must be provided (7 foot min with some exceptions) R305 1 FOOTINGS, FOUNDATIONS, AND CRAWL SPACES 18 All footings including exterior isolated pad footings must have a 24 (min ) depth from the bottom of the footing to finished grade R403 1 4 1 19 All footings shall be supported on undisturbed natural soils or engineered fill Any placement of fill material that will support a structure will require a geotechnical investigation and report submitted to the City prior to placement of footings R401 2 & R403 1 20 Lots shall be graded to drain surface water away from foundations The grade shall fall 6" in the first TEN feet around the perimeter of the structure R401 3 21 Top surface of footings shall be level Bottom surface of footings shall not have a slope that exceeds (1) unit vertical in (10) units horizontal Any necessary stepping of the foundation must be approved during plan review or prior to installation of the foundation R403 1 5 T Building/Handouts/Residential Plan Review Guidelines (Rev 03-18-09) Page 2 of 8 1 22 Wood sill plates of all exterior walls interior bearing walls (slab-on-grade) and interior shear walls (slab-on- grade) must be anchored to foundation or slab with '/ X 10" J-bolts with a 2' X 2' X 3/16' plate washer Anchor bolts to be placed a maximum of 12" and no closer than 3 1/ from the ends of the sill plate Each piece of sill plate must have a minimum of (2) anchor bolts Anchor bolts shall be spaced no further than 6 feet apart. (Special spacing and sizing conditions may apply at alternate braced wall panels) R403 1 6 23 6' clearance required from finish grade to foundation mudsill plate R319 24 3 1/2' (min ) thickness for all concrete slabs-on-grade R506 1 25 Footing and foundation wall SIZES for two pour system (Foundation walls NOT over 5 feet in height) • Footing supporting single story- 12" wide X 6' thick. • Foundation wall supporting single story- 6' thick • Footing supporting two stories- 15' wide X 7" thick. • Foundation wall supporting two stories- 8" thick. • Foundations that support more than two stories require an engineered design 26. Footing and fnd REINFORCEMENT for two pour system ( fnd walls NOT over 5 feet in height) (Footings supporting single or two stories) • One continuous #4 horizontal rebar placed at center of footing with 3" (min ) clearance from dirt. (Foundation walls not over 5 feet in height) • One continuous #4 horizontal rebar placed within the top 12" of the wall • #4 vertical rebar placed at 48 inches o c max (wet set ok) with a 6-inch 90-degree hook. A minimum of (2) vertical bars to be placed at front garage wall returns 27 Monolithically poured foundation systems • Bottom of footing shall be 12' wide (min ) and extend to 24 below finished grade minimum • Footing shall have either one #5 continuous horizontal rebar placed at center and 8" above bottom of footing or (2) #4 continuous horizontal rebar placed at center and in the middle third of the footing measuring vertically • 3 1/2" minimum slab thickness • When a monolithic system is used to support heated spaces an R 10 insulation board must be installed on the outside of the foundation extending from bottom of footing to top of slab Exposed foam insulation above grade must be protected from damage and sun with approved materials The material used must extend a minimum of 12' below grade 28. Basement Walls (up to 9 feet) or Stem Walls (over 5 feet) or STEPPED FOUNDATIONS There are special restrictions for this type of foundation wall under the new code In plan view the length of this type of wall cannot exceed 35 feet. For stepped foundations this wall cannot exceed 7 feet high otherwise the floor joists must connect DIRECTLY to the wall (for bracing the foundation wall) WET-SETTING IS NOT allowed for the alternating hooks into the footing There are special blocking requirements if any of these conditions cannot be met (note on the plans!) See R404 1 29 Under-floor pier pads supporting uniform load of wood framed floors shall be 18"x 18" x 8' (min ) Point loads from other than floor girders will require larger footings sized according to the concentrated load R403 1 1 30 Beams and/or girders in crawl space must meet span requirements for the loads imposed (from floor joists and from any point loads) R501 2 r T Building/Handouts/Residential Plan Review Guidelines(Rev 03-18-09) Page 3 of 8 1 31 Access shall be provided to all under-floor spaces Access openings through the floor shall be a minimum of 18' x 24 Openings through a perimeter wall shall be a minimum of 16" x 24 R408 3 32. Under-floor spaces shall be ventilated by openings providing-one (1) square foot of vent area per 150 square feet of crawl space area One such ventilating opening shall be within 3 feet of each corner of the building R408 2 33 A ground cover of 6 mil black polyethylene or approved equal shall be laid over the ground within crawl spaces The ground cover shall be overlapped 12" and extend to the foundation wall WSEC 502.1 6 7 34 The under-floor grade shall be cleaned of all vegetation and organic material All wood forms and construction debris shall be removed prior to final inspection R408 35 Thickened-slab footings must be 12' min total depth (top of conc. slab to bottom of footing = 12' total) (Revised from IRC) 36 Foundation cripple walls shall be framed of studs not less in size than the studding above Cripple walls with a height less than 14 inches shall be sheathed on one side with a wood structural sheathing or shall be of solid blocking Cripple walls count as an additional "story"for lateral purposes R602 9 FLOOR FRAMING 37 18" (min ) clearance beneath all floor joists and 12".(min ) clearance beneath floor girders (beams) in crawl spaces R308 38. Span of all joists (including 2nd level joists) must meet minimum live load of 40 psf (general living areas) or 30 psf (sleeping rooms) together with dead load of materials used R301 5 and Table R301 5 39 Span of beams for 2 d level or other supporting elements must meet minimum live and dead load requirements R3015 40 Wood posts in the crawl space shall have a connection to the concrete pier and a moisture barrier between the post and footing (or use pressure-treated posts) R319 & R407 41 Solid-sawn floor joists shall be blocked at all bearing points Engineered floor joists shall be installed per manufacturer's specifications R502.7 42. Cutting drilling and notching of floor joists shall not exceed the limitations in Figure R502 8 43 Cutting drilling and notching of engineered [-joists shall be in accordance with the manufacturer's specifications R502.8 2 44 All concentrated point loads originating from roof or floor load shall be transferred to bearing footings or foundation walls Continuous support shall be provided by members that are equal in cross-sectional area to the area of the load imposed and shall not be reduced in size at any point. 45. Wood members supported in concrete or masonry pockets shall have a Y2 inch air space provided at tops sides and ends of the member 46 All foundation plates sills and sleepers bearing on a concrete foundation or slab that is in direct contact with the ground shall be pressure treated All wood-framing members that rest on concrete foundations and are within 8' of exposed ground shall be pressure treated R319 T Building/Handouts/Residential Plan Review Guidelines (Rev 03-18-09) Page 4 of 8 47 Sawn lumber floor joists shall have 1'/ (min ) bearing and shall lap 3" min at intermediate girders Engineered I-joists shall have 1 3/4 (min ) bearing (or per manufacturer's specifications) 48 Floor joists that are parallel to bearing partitions shall be doubled Some heavier load cases will require girder beams or pony walls Bearing partitions perpendicular to floor joists shall not be offset from the supporting girder more than the depth of the joists unless the floor joists are of sufficient size to carry the load R502 4 49 Floor cantilever spans shall not exceed the depth of the nominal floor joists Floor cantilevers constructed in accordance with Table R502 3 3 (1) shall be permitted when supporting a light framed bearing wall and roof only R502.3 3 50 .Block in between floor joists beneath all interior braced walls (for walls perpendicular to joists) or align floor joist with interior braced wall (see item #63-T) WALL FRAMING 51 Wall studs taller than 10 feet shall have a stud height analysis by a professional engineer or architect. Table R602 3 5 52. Non-load bearing stud heights shall be in accordance with Table R602.3 (5) 53 Studs shall be a minimum #3 grade standard grade or stud grade lumber R602.2 54 Where joists trusses or rafters are spaced more than 16' o c and the bearing studs below are spaced at 24 o c. such members shall bear within 5 of the studs below unless the top plates are double 2x6 or a third plate is added R602 3 3 55 Headers over windows and doors must meet minimum requirements for spans and imposed loads verify point loads over openings (from trusses or other conditions) and size headers accordingly Headers must be noted with size type and grade of lumber being used GENERAL NOTE STATING ALL HEADERS SHALL BE is acceptable 56 Interior bearing walls must have headers over openings and must be supported to a foundation 57 Top plate splices shall be offset a minimum of 24 inches R602 3 2 58. Fire-blocking required at dropped ceilings soffits coved-ceiling areas and every ten feet horizontally and vertically at framed walls R602 8 59 Port Angeles is in Seismic Zone D1 Wind zone of 100 MPH Category C (within 1500 ft from shore line is Category D) per the 2006 IRC When a house is considered IRREGULAR by any ONE the definitions below the code will NOT allow prescriptive bracing for Seismic Zone C and the entire house must have a lateral analysis and design by a licensed engineer (R301 2.2.2.2) Per that section of the code NO MIXING OF PRESCRIPTIVE AND ENGINEERED LATERAL SYSTEMS IS ALLOWED UNDER THIS NEW 2006 IRC. The following are items that constitute an IRREGULAR BUILDING per the-2006 IRC A. Exterior braced wall lines must be in one plane vertically from foundation to the uppermost story (basically the upper floor must match the lower floor footprint) The most common area where problems like this occur is in a garage with a second floor over it. To qualify for prescriptive bracing the second floor joists must extend to the exterior walls of the garage If this does NOT occur then your proposed house is IRREGULAR. If the joists do extend to the exterior walls of the garage then the setback of the second floor walls cannot be more than four (4) feet setback from the garage walls T Building/Handouts/Residential Plan Review Guidelines (Rev 03-18-09) Page 5 of 8 (see p 44 of the 2006 IRC) Rooms created by roof trusses are OK under this provision (such as bonus rooms over garages formed by the trusses/rafters) B The perimeter of all floor diaphragms and all roof diaphragms must be supported on WALLS below If you have beams holding up any part of the perimeter of a floor or a roof then your proposed house is IRREGULAR The most common place you will find this problem is at large covered porches and patios where the roof is supported only by post and beams Such covered porches and patios also make the building IRREGULAR Related to this are areas of discontinuous diaphragms especially changes in plate line heights which also are considered as separate roofs and therefore make the building IRREGULAR. C In any elevation of the exterior the braced walls from an upper level wall must NOT occur over a window or door In general this means that the windows of the upper story must align with the windows of the lower story There are some exceptions based on up-sizing the header in the window below (see 2006 IRC p 44 for details) D When an opening in a floor or roof (such as a balcony-overlook area or a courtyard area) exceeds the lesser of 12 feet or 50% of the least dimension then your proposed house is IRREGULAR E. When portions of a floor level are vertically offset (such as a sunken room) then your proposed house is IRREGULAR This does not apply to a slab-on-grade floor F When braced wall lines do not occur in two perpendicular directions (such as portions of the house or garage at an angle to the rest of the building) then your proposed house is IRREGULAR. G If you have any portion of the above-grade walls that use masonry or concrete construction then your proposed house is IRREGULAR Stepped foundations that create a daylight basement situation are OK under this provision and do not make an irregular structure 60 THIS APPLIES TO ALL LATERAL BRACING (ITEMS 61 THRU 65) Add up all lengths of braced panels (4 foot braced panels 2-8' alt. braced panels and 24 or 16' portal frames COUNT as 48' of length each portal frame counts as a total of 48' of bracing length—not 2 times 48") along the wall in question The total length of braced walls must be at least 16% of the entire wall length AND the panels must occur at least every 25 feet along the wall For 1St story of 2-story house 30% of the entire wall length must be braced walls Check this for all braced wall lines including INTERIOR WALLS and including the front wall of a garage if it is not part of another braced wall line (i a the garage sticks out in front of the house more than 4 feet) See also#65 T below for areas where MORE than 35 feet between wall lines is needed 61 Garage lateral bracing systems with no 2nd floor above H Portal Frame for Garages (16" side panels @ 8 foot max. high walls 20" side panels @ 10 foot max. high walls) Alternate Braced Walls—single-story condition (2'-8' min width X 10 foot max. height) sheathed on one side (interior or exterior OK) with min 3/8" OSB or plywood and nailed with 8d common or galv box nails and blocked at all edges Two (2) anchor bolts in sill plate & two (2) hold-down devices @ furthest studs (1800 pound capacity hold-downs) J Alternate Braced Walls—first floor of two-story condition (2'-8' min width X 10 foot max. height) sheathed on BOTH interior and exterior sides of wall with min 3/8' OSB or plywood and nailed with 8d common or gals box nails and blocked at all edges Two (2) anchor bolts in sill plate & two (2) hold- down devices @ furthest studs (3000 pound capacity hold-downs) There are some provisions for plate lines up to 12 feet high see Table R602 10 6 (basically a wider wall 3-6' min length for 12 feet high) K. Front Garage Panels—no hold-downs required L. The exterior braced wall lines in a detached or attached garage cannot be more than 35 feet apart in either direction or interior braced walls must be provided 62. 1St Floor Conditions - Four (4) foot solid walls at.all corners and at every 25 feet along any braced wall line OR use one of the methods below M Portal Frame for a House (slab-on-grade floors ONLY) 16" min width for one-story structures 24" min width for first floor of 2 story T-Building/Handouts/Residential Plan Review Guidelines (Rev 03-18-09) Page 6 of 8 N Alternate Braced Walls—single-story condition (2'-8' min width X 10 foot max. height) sheathed on one side (interior or exterior OK) with min 3/8" OSB or plywood and nailed with 8d common or gals box nails and blocked at all edges Two (2) anchor bolts in sill plate & two (2) hold-down devices @ furthest studs (1800 pound capacity hold-downs) O Alternate Braced Walls—first floor of two-story condition (2'-8" min width X 10 foot max. height) sheathed on BOTH interior and exterior sides of wall with min 3/8' OSB or plywood and nailed with 8d common or gals box nails and blocked at all edges Two (2) anchor bolts in sill plate & two (2) hold- down devices @ furthest studs (3000 pound capacity hold-downs) There are some provisions for plate lines up to 12 feet high see Table R602 10 6 (basically a wider wall 3-6' min length for 12 feet high) P "Simpson Brand StrongWalls—this method is still available following all the manufacturer's specifications for connections Q Entire House Sheathed with OSB or Plywood—this method allows smaller side panels than 4 feet in accordance with Table R602 10 5 CHECK THE OPENING HEIGHTS ADJACENT TO THESE PANELS! 63 1st Floor Conditions – Braced wall (any of the methods listed above) must start at no more than 12 5 feet away from the corner of the braced wall lines and then at every 25 feet (min ) along the wall line 64 2nd Floor Conditions – Braced walls (either of the methods listed below) must be within 12.5 feet of the corner of the wall line in question R. Standard four (4) foot panels on 2nd levels can start at no more than 12 5 feet away from the corner S Entire House Sheathed with OSB or Plywood—this method allows smaller side panels than 4 feet in accordance with Table R602 10 5 CHECK THE OPENING HEIGHTS ADJACENT TO THESE PANELS! 65 Exterior braced wall lines (or together with some interior wall lines) cannot be more than 35 feet apart. T Certain areas can be up to 50 feet apart between wall lines IF there is additional bracing along the exterior wall in question (50/35 = 1 43 more bracing than normally required or in other words 23% of the total wall in bracing for 1-story wall 43% of the total wall in bracing for 1st story of a 2-story house) R602 10 1 1 Exception 1 and 2 U Interior Braced Walls can be used when exterior walls are more than 25 feet apart. Interior Braced Walls are minimum 1/2' GWB both sides of wall for a minimum length of 48' use 5d nails or screws at 7' o c Sole plate of wall must be attached to thickened slab footing (see item #22 above) with 1/2" anchor bolt @ 6'-0' o c or solid blocking (walls perpendicular to joists) or LINE UP JOIST with braced wall (walls parallel to joists) 66 The roof sheathing MUST nail into SOLID blocking and the block must connect to the double top plate either with clips or toe-nailed (for blocks that are top-beveled) with 8d @ 6' o c For ventilation use not more than two (2) 2' diameter holes BLOCKING MUST OCCUR AROUND ENTIRE PERIMETER OF ALL ROOFS Table R602 3 (1) This applies to all houses both engineered AND prescriptive bracing ROOF & ATTIC 67 Truss drawings must show reactions of all girder trusses point loads onto headers must have headers sized accordingly point loads over 5000 lbs onto double-top plates must be checked for bearing capacity Use 'Simpson brand TBE4 or TBE6 as needed to spread the load 68 Truss bottom chord live load must be minimum of 10PSF (see Table R301 5) Trusses must be sized for the roof coverings specified on the plans (concrete tile etc ) and roof structure must be able to hold up the roof(beams headers etc sized for-roof loads) R802 10 2 69 Ice Shield is required for roofs up to 6 12 (6 12 and over DO NOT require ice shield) R905 2.7 1 T Building/Handouts/Residential Plan Review Guidelines (Rev 03-18-09) Page 7 of 8 4 70 Attic ventilation must be provided at 1/150th of the attic area or 1/300th of the attic area if 50% of the venting can be 3 feet above the eave venting (roof jack vents are 49 sq in./vent, ridge vents at 12 sq in./foot) R806 1 71 Attic mechanical equipment need light and switch near opening and electric outlet. Access opening to such mechanical equipment must be no further than 20 feet from equipment with 22" wide (min ) walkway from access opening to the equipment. 72.Attic access required 22' X 30" min and shall be in hallway or other readily accessible location R807 1 MECHANICAL. 73 Appliances located in a garage or carport shall be protected from damage from vehicles M1307 3 1 74 Gas appliances located in a garage shall be raised 18' min above finish floor G2408 2 (305 3) 75 Ductwork that extends below grade (such as in the garage floor) shall be encased in 2' min concrete on all sides and bottom in addition to the R-10 insulation foam board 603 8 IMC 76 Dryer exhaust ducts shall not exceed 25 feet in length The maximum length of the duct shall be reduced 2 5 feet for each 45-degree bend and 5 feet for each 90-degree bend. Longer lengths in accordance with the manufacturer's listing will be allowed Screws shall not be used to connect any dryer duct materials M1501 3 77 Flex duct connections to sheet metal transition ducts shall have the inner sleeve taped with approved materials prior to securing the flex duct with a zip tie or similar fastener 304 IMC 78 Flex duct shall be supported every 4 feet and have no sag that exceeds 1/2 per foot. 79 All exhaust fan ducts shall be connected to the fan housing and termination fittings with a minimum of 3 sheet metal screws and be sealed with approved tape or mastic. 80 Exhaust fans required 50 cfm in bathrooms 100 cfm in kitchen 50 cfm min in laundry room and one fan sized for whole-house ventilation 302 2 2 WSVIAQ 81 Fuel-burning equipment shall not be installed in a closet, bathroom or a room readily usable as a bedroom 82. Water heaters must be secured to structure with straps around tank at 1/3 points to resist lateral displacement. M1307 2 PLUMBING 83. Cleanouts shall be installed on all sinks and at the upper end of all building drains including any horizontal drain branches greater than 5 feet in length from the main line A cleanout shall also be installed on the exterior of the house within 24 Inches of the foundation wall level with final grade and shall have a threaded type cap installed 84 30' min width for toilet and 24 clear space in front of toilet (UPC) 85 Water heaters pressure relief and the required drain pan shall have a drain that is 3/ ID copper or cpvc material NO coil material shall be allowed per code and no reduction in the pipe shall reduce the ID of the material less than 3/ Pex type is a coil material and is not allowed for this application T Building/Handouts/Residential Plan Review Guidelines (Rev 03-18-09) Page 8 of 8 p°HT.,,,,�`, BUILDING PERMIT APPLICATION Print in Ink �`''�►'�►-- CITY OF PORT ANGELES For City Use Only: w_ Attn Building Permit Technician Date Recei ed - _lo 321 E. Fifth St. Port Angeles WA 98362 Permit# — (360) 417-4815 fax (360)417-4711 Date Approved Applicant iytCPhon 3Go AibO 1761 Property Owner ;c -yc, S C , Phon 3 Q 95? Property Owner's Address I -� -� Contractor &Ce- cW --r-;AC, Phone 3C0 '117 57 Contractor's Address + r License # Expires E-mail eft 5�aC,cCYta PROJECT ADDRESS - cPOOLI- Sfk S gWCS0 Parcel Number 0(e 300 09 3 /0 8 O Lot Zoning �S Project Type & Brief Description. Residential ❑ Multi-family ❑ Commercial ❑ Industrial Check all that apply 'New Construction ❑ Addition ❑ Remodel ❑ Repair ❑ Demolition ❑ Re-roof ❑ House ❑ garage ❑ other ❑ tear off& re-roof ❑ lay over one layer X'Heat System ❑ Heat pump ❑ wood-burning stove ❑ gas fireplace ❑ pellet stove ❑ other ❑ Other 9 E�C. 0. W Floor Areas Existing(sq. ft.) Proposed(sq. ft.) Basement @ $ per sq ft. _ $ 1 s' Floor 2nd Floor 3rd Floor Garage S 30 I D Carport Covered Porch Deck Shed Other TOTAL VALUATION $ 1 3) l G Total footprint of structures sq ft. T Lot size (,-7 sq ft. = Lot coverage7� , % Site Coverage = the amount of impervious surface on a parcel including structures paved driveways sidewalks, patios and other impervious surfaces (see PAMC 17 94 135 for exemptions) Site coverage 95% Max. height of proposed structures 1 (o ft. Occupancy group - # of bedrooms 3 Will a lawn sprinkler system be installed? Occupant load #of full baths —2- Will Will a fire sprinkler system be installed? Construction type #of half baths /have read and completed this application and know it to be true and correct. /am authorized to apply for this permit and understand that it is my responsibility to determine what permits are required, and to obtain permits prior to work' on projects Date L- "16 Print Name I ek V Cf%J b 1 L I— Signature T Forms/Building Division/Building permit application 2002 "2015 j 714 1938- 2007 O -2005 2024 7 2003: 00 727 063 S(7 L 2002 / 1929 ✓ J 1942 w� 7� 1943 / Westview Dr ®NNMINIM®®®®NMImmommo®Nm®NNE IM NEM ®®NIMNIMNM®®®IM®® mm MENNINNIMIMNUMMI somommom ®®®®IM®ESENON SMENIM®MINMIN MEMOS MIM®NIM®®MI®®®IME®N®®®IME OEM MEMINEMISME ®®MI®ION®ONES M IME 0 ®®®®11 ®NIMNNi���IMNIMNN IM®®®®MEE ENNIS NN®®®;IMN®®®®®®MO®NIMN®®®IM®IM ®®®MIII ®®IM®®®®®®®®®®®®®®®®IM®® ®®NI®! m ems® 11®®IM�N�m®®®®m®mm®®l® m- Elloomms MEN SHE ®IM®11 NNVNl�NN®�®�®®N®®®N waimmilmons®®v ®®®soon®��®® 1INNWEE ®®IMS®®®IM®® �11ml 'NN® N®®®IMS®N®®® MMI®11®MINIM®anNNNIM ®®ONNIMN®® MI®® PRESCRIPTIVE APPROACH-SIMPLE FORM For the Washington State Energy Code (2006 Edition) Climate Zone 1 CITY GOVERNMENT Site Information. Building Department Use Only Lot: ? (�)p C)� ` CS�-yuA.J Permit# Address Notes City- P k State Zip Contact. �,V,4 Phone 3 Q,O y G 0 G (-7 Phone 2 FAX 3C.0 Table 6-1 PRESCRIPTIVE REQUIREMENTS FOR GROUP R OCCUPANCY CLIMATE ZONE 1 (Unlimited Glazing Option Only) Glazing Glazing,,,U`=Factor. :Door ' `1Nall ":Walt f VaUlt6d Interior 'Exterior 'Slati on, Qption_ `Area,%:of, = 3... . ., ....; U- "Ceiling ;: '=... . Above ;F.loor' Floor °f`"Uerticali '.`<Overhead`'` Factor •Ceiling Glade, Below=_. :Below Concrete . .Grades ;Grade,. Unlimited Group R 3 IV and R-4 0.35 058 0.20 R 38 R 30 R 21 R 21 R 10 R 30 R 10 Occupancies Only This Project complies with the following- The project is a single-family residence or duplex. The project is a wood frame OR all of the insulation is interior or exterior of the framing. All building components meet the requirements listed above The project will meet all other provisions of the WSEC and VIAQ The Project will take advantage of the following exceptions to the prescriptive option. ❑ 602.6 Exception 2. One unlabeled or untested exterior swinging door 24 sq ft. or less, may be installed per unit for ornamental, security, or architectural purposes Location of the door taking this exception ❑ 602.6 Exception 2. If a door is mostly glass, it should meet the requ>rement,of the vertical glazing U factor listed above Location of the door(s)taking exception. Type of Heat Source. C ' 0, q T Forms/Building-Division/Prescriptive Approach-Simple Form M �.� CD Electrical Information Form 1. Public Works&Utilities Department(360)417-4700 m c City Electrical Inspector(360)417-4735 3 Please complete and return to Public Works& Utilities Department Permanent service. Name Ac-e- ,C Sj�, �L� C .7 ►\ Name and address of party Street: Wes 4 /v S T P* responsible for permanent City 1 State / ZIP' fs 3�3 a service billing? Daytime Phone Q (-o G I? Home Phone • • (if other than above) Site contact: Name Title ' Daytime Phone Contractor Name Company- C c �C Daytime Phone C2,CD Electrician. Name Company- Daytime ompanyDaytime Phone Excavator Name Com an Daytime Phone • - • ❑Existing >lNew IEXSingle-family residence El Multi-family residence #of units ❑Commercial []Subdivision #of lots ❑Overhead service EJ General service underground service ❑Other • - • • Description of work: N2Uj Street address/lot number p $ Je i t-D Nearest cross street: Desired connection date Electrical transformer serving property is ❑on a pole ❑ on the ground Total square footage7 sq ft. Main disconnect size amps Voltage ZJ20/240 1ph ❑120/208 3ph ❑277/480 3ph 0120/240 3ph ❑480 3W 3ph ❑ Other 0 Standard residential loads (Lighting refrigerator dishwasher washer) Check all that apply ❑A/C (_ton) ❑Range/Oven ❑Hot Tub ❑Clothes Dryer ❑Heating ❑Pumps (_Hp). ❑No Load Change ❑Water Heater ❑Elevator(_Hp) ❑Other • • • • • Please.provide a copy of the following "Detailed plot plan ( dwg or dxf format mandatory for subdivisions) "Electrical one-line drawing showing the service entrance panel and location `Connected load data 'Size and locked rotor ames of aA motors o r 50h Applicant's Signature Date MAIL OR DELIVER COMPLETED FORM TO 321 E 5TH STREET PORT ANGELES WA 98362 FAX TO 360-417-4711 WS WF Informa on form.xls N :P`*S\LIGHT NCPI-10rigir difformationfunn Rew 1 5-0"- ' O 9s 714 8,L� ,938" ti ,Cl 4W# /� A 200 '2024- -�.Q ?O V O . / L N� 91(9 � 3. � Pll�o Sly (9 .727Zo 1929 2002 Al 7Y / 1 4942 westVPG-wDr 1�` Clallam County Assessor& Treasurer - Property Details - 62725 ACE MICHAELS INC Page 1 of 3 Clallam County Assessor & Treasurer Property Search Results > 62725 ACE MICHAELS INC for Year 2010 - 2011 Account Property ID_ 62725 Legal Description WEST VIEW LOT 8 BL 1 Geographic ID- 0630009310800000 Agent Code Type. Real Tax Area. 0010 PA 121 PORT ST CNTY H2 L Land Use Code 91 Open Space. N DFL N Historic Property- N Remodel Property- N Multi-Family Redevelopment: N Township- Section. Range Location Address. �� W EIGHTH ST � Mapsco PORT ANGELES WA Neighborhood: Cycle 5 Res Map ID- Neighborhood CD- 10955130 Owner Name ACE MICHAELS INC Owner ID- 10145 Mailing Address: 1329 W 10TH ST %Ownership 100 0000000000% PORT ANGELES WA 98363 Exemptions. Taxes and Assessment Due j Property Tax Information as of 06/28/2010 Amount Due if Paid on. . First Half ,Second Half j Year I Statement ID Taxing Jurisdiction Base Due Base Due Penalty Interest i Base {2010 45291_ ST S_CH STATE SCHOOL $72.16 $72.16 $000 $000 $7 2010 45291_ CC-GEN COUNTY _ $3840 $3840 $000 $000 $_: 2010 45291 PORT PORT $540 $539 $000 $000 1 2010 45291 _ PORT ANG PORT ANGELES $8891 _ $8891 $000 _ $_0.00 $E 2010 45_2_91 SD#121_SCHOOL DISTRICT#121 $9346 $9347 $000 $000 $f 2010 45291 NTH OLY LIB NORTH OLYMPIC LIBRARY $11 16 $11 16 _ $000 $0 00 $1 12010 45291 HOSP_#2 HOSPITAL#2 $1576 $1575 $000 $0_00_ $1 i2'010'45291 WSMET PK DIST WILLIAM SHORE MET PARK DIST _ $501 _ $501 $000 $000 9 2010 45291 WEED—CONTROL WEED CONTROL $0 82 $081 $000 $0 00 9 2010 45291 TOTAL. $331.08 $331.06 $0.00 $0.00 $32 2009 627252008 ST SCH STATE SCHOOL $7954 $7953 $000 $000 $1E '2009 627252008 CC-GEN COUNTY $40.26 $40.24 $0_00 _$000 $f 2009 627252008 PORT PORT _ $570 $570 $000 $000 $1 2009 627252008 PORT ANG PORT ANGELES $8830 $88.27 $000 $000 $17 20_09 627252008 _SD#121 SCHOOL DISTRICT#121 $9836 _ _ $9836 $000 $000 $15 2009 627252008 _NTH OLY LIB NORTH OLYMPIC LIBRARY $11 70 $11.69_ $000 � $000 $2 2009 627252008 HOSP#2 HOSPITAL#2 $1651 $1651 $000 $000 $1, 2009 627252008 WEED CONTROL WEED CONTROL $082 $081 $000 $000 _ 9 2009 627252008 TOTAL. _ $341 19 _$341 11 $0.00 $0.00 $6E http.//vpn.clallam.net 8084/propertyaccess/Property aspx?cid=0&year=2010&prop_id=62 6/28/2010 O ELECTRICAL PERMIT O CITY OF PORT ANGELES O 360-417-4735 m Application Number 10 00000705 Date 7/08/10 Application pin number 331445 Property Address 2004 W STH ST REPORT STATE SALES TAX ASSESSOR PARCEL NUMBER 06 30 00 9 3 1080 0000 on your excise tax form Application type description ELECTRICAL ONLY Subdivision Name to the City of Port Angeles Property Use (Location Code 0502) Property Zoning RS7 RESDNTL SINGLE FAMILY Application valuation 0 Application desc Temp Pole Owner Contractor ACE MICHAELS INC JEDI ELECTRIC 1329 W 10TH ST 331 FORS RD PORT ANGELES WA 98363 PORT ANGELES WA 98362 (� (360) 417 9579 (360) 460 0556 \) Permit ELECTRICAL TEMPORARY SERVICE Additional desc Permit pin number 168922 Permit Fee 92 70 Plan Check Fee 00 Issue Date 7/08/10 valuation 0 Expiration Date 1/04/11 Qty Unit Charge Per Extension 1 00 92 7000 ECH EL TEMP SRV 0 200 SRV FDR 92 70 Fee summary Charged Paid Credited Due Permit Fee Total 92 70 92 70 00 00 Plan Check Total 00 00 00 00 Grand Total 92 70 92 70 00 00 V INSPECTION TYPE DATE. RESULTS INSPECTOR. DITCH SERVICE l o ROUGH IN FINAL g COMMENTS PERMIT WILL EXPIRE SIX(6)MONTHS FROM LAST INSPECTION Signature of owner or Electrical Contractor X Date. pURT CITY OF PORT ANGELES PERMIT APPLICATION JUL u Building Division/Electrical Inspections 321 East Fifth Street—P O Box 10/Port Angeles Washington,98362 ELECTRICAL -- ' Ph (360) 417-4735 Fax. (360) 417-4711 INSPECTIONS Date. / ",3-I d 41 &2 Single Family Dwelling _Multi-Family or Commercial* _Commercial Addition/Alteration/Remodel/Repair* *Plan Review May Be Required, Please Complete Electrical Plan Review Information Sheet Job Address: X00 1-j lnl e5 7- F r� Building Square Footage: Description of above /_J c,-2 7"e vh? f!o tie e- Owner Information Contractor Information Name:0 '14 e- Cot-d. /J Name: SEDZ Elcc7r, C- Mailing Address: Mailing Address: P.o, C3c x 3S8' City State: . Zip: City P A State: I.J-. Zip: '3,P36;L Phone: Fax: Phone: r-lG o- o S S(b Fax: Kr> -I yo7 License#I Exp. License#/Exp. T L4b_*P G E -)C- riS 7 C-2- Item Item Unit Charge QtV Total(Qty Multiplied by Unit Charge) Service/Feeder 200 Amp. $119.90 $ Service/Feeder 201-400 Amp. $145.50 $ Service/Feeder 401-600 Amp $204.60 $ Service/Feeder 601 1000 Amp. $262.20 $ Service/Feeder over 1000 Amp. $372.50 $ Branch Circuit W/Service Feeder $ 2.60 $ Branch Circuit W/0 Service Feeder $ 73.50 $ Each Additional Branch Circuit $ 2.60 $ Temp.Service/Feeder 200 Amp. $ 92.70 $ 112, 70 Temp.Service/Feeder 201-400 Amp. $110.30 $ Temp.Service/Feeder 401-600 Amp. $14870 $ Temp.Service/Feeder 601 1000 Amp $167.90 $ Portal to Portal Hourly $ 95.90 $ Sign/Outline Lighting $ 88.20 $ Signal Circuit/Limited Energy/First 1500 sf-Commercial $ 95.90 $ Note: $5.00 for each additional 1500 sf Signal Circuit/Limited Energy 1 &2 Family Dwelling $ 63.90 $ Signal Circuit/Limited Energy Multi-Family Dwelling $ 63.90 $ Manufactured Home Connection $119.90 $ Renewable Electrical Energy 5KVA System or Less $102.30 $ Thermostat $ 56.00 $ NEW CONSTRUCTION ONLY. First 1300 Square Ft. $110.30 $ Each Additional 500 Square Ft.or Portion of $ 35.20 $ Each Outbuilding or Detached Garage $ 73.50 $ Each Swimming Pool or Hot Tub $110.30 $ %L 70 Total Owner as defined by RCW 19.28.261 (1)Owner will occupy the structure for two years after this electrical permit is finalized. (2) Owner is required to hire an electrical contractor if above said property is for sale, rent or lease. Permit expires after six months of last inspection. After reading the above.statement, I hereby certify that I am the owner of the above named property or a licensed electrical contractor I am making the electrical installation or alteration in compliance with the electrical laws, N.E.0 RCW Chapter 19.28, WAC Chapter 296-46B, The City of Port Angeles Municipal Code, and Utility Specifications and PAMC 14 05.050 regarding Electrical Permit Applications. Signature of owner electrical contractor or electrical administrator ❑ cash ;`1 Check ❑ Credit Card# x Dated: _ 1 O 0110112010