Loading...
HomeMy WebLinkAbout114 W 10th St - BuildingCITY OF PORT ANGELES PUBLIC WORKS & UTILITIES 321 EAST 5TH STREET PORT ANGELES, WA 98362 Application Number 09 00001345 Date 12/29/09 Application pin number 700055 Property Address 114 W 10TH ST ASSESSOR PARCEL NUMBER 06 30 00 0 3 2720 0000 Tenant nbr name QWEST Application type description PUBLIC WORKS UTILITES Subdivision Name Property Use Property Zoning RS7 RESDNTL SINGLE FAMILY Application valuation 0 Application desc 30 burried phone cable R/W 09 01 Owner Contractor DOYLE DENNIS MICHAEL EXCEL UTILITIES CONSTRUCTION 1233 E 3RD ST 54 W MISTY IN PORT ANGELES WA 983627818 PORT ANGELES WA 98362 (360) 452 1110 Permit RIGHT OF WAY Additional desc 30 BURRIED PHONE R/W#09 01 Permit pin number 158691 Permit Fee 150 00 Plan Check Fee 00 Issue Date 12/29/09 Valuation 0 Expiration Date 6/27/10 Qty Unit Charge Per Extension 1 00 150 0000 ECH PW RW CONST EXCAVTION OTHER 150 00 Special Notes and Comments Traffic control plan to be submitted to and approved by the City prior to excavation Permit fee does not include surface restoration Fee summary Charged Paid Credited Due Permit Fee Total 150 00 150 00 00 00 Plan Check Total 00 00 00 00 G Grand Total 150 00 150 00 00 00 Separate Permits are required for electrical work, SEPA, Shoreline ESA, utilities private and public improvements This permit becomes null and void if work or construction authorized is not commenced within 180 days if construction or work is suspended or abandoned for a period of 180 days after the work as commenced, or if required inspections have not been requested within 180 days from the last inspection I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The grantingof a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction Signature of Contractor or Authorized Agent T-\Policies\1102 15 (10/08] Date Signature of Owner (if owner is builder) Date PERMIT INSPECTION RECORD CALL 417-4831 FOR UTILITY INSPECTIONS PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. ITIS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT INA CONSPICUOUS LOCATION KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE INSPECTION TYPEI DATE I ACCEPTED COMMENTS YES I NO PW UTILITIES (Engineering Division) WATERLINE / METER SEWER CONNECTION SANITARY STORM SITE DRAINAGE SITE EROSION CONTROL PARKING SIDEWALK CURB & GUTTER DRIVEWAY APPROACH BACK-FLOW DEVICE 1 FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE RESIDENTIAL DATE YES NO COMMERCIAL CONSTRUCTION R. W / PW/ CONSTRUCTION R. W ENGINEERING 417-4831 PW / ENGINEERING FIRE 417-4653 FIRE DEPT PLANNING DEPT 417-4750 PLANNING DEPT BUILDING 417-4815 BUILDING T \Policies\1102.15 [10/081 DATE ACCEPTED YES NO PREPARED 12/11/09 8 16 36 INSPECTION TICKET PAGE 2 CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 12/11/09 ADDRESS 114 W 10TH ST SUBDIV TENANT NBR DENNIS MICHAEL DOYLE CONTRACTOR PHONE OWNER DENNIS MICHAEL DOYLE PHONE (360) 457 1902 PARCEL 06 30 00 0 3 2720 0000 APPL NUMBER 09 00000408 RES NEW SFR REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS AFTERNOON December 7 2009 4 14 58 PM jlierly BLI O1 12/11/09 BLDG INSULATION December ZO 2009 11 37 53 AM 1pangrle LARRY 775 1924 INSULATION COMMENTS AND NOTES PREPARED 12/07/09 9 55 35 INSPECTION TICKET PAGE 1 CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 12/07/09 ADDRESS 114 W 10TH ST SUBDIV TENANT NBR DENNIS MICHAEL DOYLE CONTRACTOR PHONE OWNER DENNIS MICHAEL DOYLE PHONE (360) 457 1902 PARCEL 06 30 00 0 3 2720 0000 APPL NUMBER 09 00000408 RES NEW SFR PERMIT BPR 00 BIIILDING PERMIT RESIDENTIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS BL1 01 6/16/09 JLL BLDG FOUNDATION FOOTING TIME O1 00 6/16/09 AP June 16 2009 9 18 33 AM 1pangrle LARRY 775 1924 FOOTING REBAR AFTERNOON June 16 2009 4 59 43 PM jlierly BL2 01 7/01/09 JLL BLDG FOUNDATION STEM WALL TIME O1 00 7/13/09 AP July 1 2009 8 19 44 AM 1pangrle LARRY 775 1924 STEMWALL AFTERNOON July 13 2009 3 49 58 PM jlierly BLFD O1 7/09/09 JLL BLDG FOUNDATION DRAINAGE 7/09/09 AP July 9 2009 10 02 17 AM permits July 9 2009 4 54 05 PM jl erly BL3 01 7/22/09 JLL BLDG FRAMING TIME 02 30 7/22/09 DA July 21 2009 3 07 26 PM 1pangrle LARRY 775 1924 UNDERFLOOR GIRDER JOIST PLEASE INSPECT AFTER 2 30 PM July 22 2009 4 12 20 PM jlierly not complete recall when ready/jll BL3 02 7/24/09 JLL BLDG FRAMING TIME 03 30 7/24/09 AP July 23 2009 1 22 43 PM 1pangrle LARRY 775 1924 BEAM & JOIST LATE AFTERNOON INSPECTION July 24 2009 4 13 54 PM jlierly BL3 03 11/16/09 JLL BLDG FRAMING TIME O1 00 11/16/09 DA November 16 2009 9 15 35 AM 1pangrle LARRY DOYLE 775 1924 FRAMING AFTERNOON November 16 2009 4 21 43 PM jlierly complete electrical rough before frame /jll BAIR O1 12/07/09 L 7 BLDG AIR SEAL TIME O1 00 �! December 7 2009 9 54 42 AM 1pangrle VV LARRY 775 1924 AIRSEAL AFTERNOON BL3 04 12/07/09 L BLDG FRAMING TIME O1 00 1 17 December 7 2009 9 54 17 AM 1pangrle iIV LARRY 775 1924 i FRAMING AFTERNOON COMMENTS AND NOTES r ELECTRICAL PERMIT 0 CITY OF PORT ANGELES -Q 360-417-4735 Application Number 09 00001269 Date 12/07/09 N Application pin number 327308 Property Address 114 W 10TH ST \� ASSESSOR PARCEL NUMBER 06 30 00 0 3 2720 0000 Application type description ELECTRICAL ONLY Subdivision Name Property Use Property Zoning RS7 RESDNTL SINGLE FAMILY Application valuation 0 Application desc New home 2200 sqft Owner Contractor —�—� T� DOYLE DENNIS MICHAEL ELECTRIC SERVICE r 1233 E 3RD ST 82 DRAPER RD PORT ANGELES WA 983627818 PORT ANGELES WA 98362 (360) 452 6424 Permit ELECTRICAL NEW RESIDENTIAL Additional desc Permit pin number 157727 Permit Fee 141 25 Plan Check Fee 00 Issue Date 12/07/09 Valuation 0 Expiration Date 6/05/10 Qty Unit Charge Per Extension 1 00 86 2500 ECH EL R SQFT FIRST 1300 86 25 2 00 27 5000 ECH EL R SQFT ADDITIONAL 500 55 00 Fee summary Charged Paid Credited Due ( n Permit Fee Total 141 25 141 25 00 00 Plan Check Total 00 00 00 00 Grand Total 141 25 141 25 00 00 INSPECTION TYPE DATE RESULTS INSPECTOR DITCH SERVICE ROUGH IN (-7 CP W FINAL l�(Jz/�� A COMMENTS Siunature of owner or Electrical Contractor X Date City of Port Angeles Permit Application Building pivision/Etectrical Inspections 321 East Fifth Street - P.O: Box 1150 Port Angeles Washington,,98362 Pia. (360) 4 -4735 Fax, (360) 4174711 Date: 1-L + tSq 2 Single Family Dwelling Multi -Family or Commercial* ^ Commercial Addition / Alteration I Remodel ! Repair* * Plan Review MAY Be Required, Please Complete Electrical Pial Job Address: t 1 q , �► '- Building Square Footage: Description of above Owner Information ' Name: mailin ddre z 3'� f. 3 ^J' I City��"^�T . State~ Zip: 4 eP C2- Phone:. '-t 'SI -7 - t Y1 Fax: E License # 1 Exp. I DEC - 2009 ELECTRICAL INSPECTIONS riew Information Sheet Contractor tnformatio[{-�--� Name: l7� °ctl� c C Mailif►q �addr L'`"f ^ U 'icy Cityor State: U -),t Zip: I x'36 a. - Phone: 1-f too- 03 �13 Fax: . c+r L-4vc42--v' License #/Exp. F --i a-crsl t 47 -ow, Unit Charge Q_yt iplied by Unit Charqe) $ 93.75 service/Feeder 200 Amp. $113.75 Service/Feeder 201-400 Amp. $160.00 Service/Feeder 401-600 Amp. $205.00 ServicelFoeder 601-1000 Amp. $291,25 $ Ij ServicelFeeder over 1000 Amp. $ 2.00 $ I Branch Circuit W1 Service Feeder $ 57.50 $ Blanch Circuit W/O Service Feeder $ 2.00 $ Each Addrional Branch Circuit $ 72.50 $ Temp. Service! Feeder 200 Amp. $ 86.25 $ - Temp. Service/Feeder 201.400 Amp. $116.25 $ Temp. Service/Feeder 401.600 Amp. $131.25 $ Temp. Service/Feeder 601.1000 Amp. $ 75.00 $ Portal td Portal Hourly $ 69.00 $ Sign/Outline Lighting $ 75.00 $ Signal Circuit/ limited Energy Commercial $ 50.00 $ I f Signal Circuit/ Limited Energy 1 & 2 Family Dwelling $ 50.00 $ Signal Circuit/ Limited Energy Multi -Family Dwelling $ 93.75 $ Manufactured Home Connection $ 80.00 $ Renewable Electrical Energy 5KUA System or Less $ 86.25 _�, $ 1 ' First 1300 Square Fl. $,27.50 _ }�_ $ �� : Each Additional 500 Square Ft. or Portion of $' 57.50 _ $ _ ___. Each Outbuilding or Detached Garage $ 86.25 $ Each Swimming Pool or Hot Tub $ 43.75 $ ,Thermostat $� S Total Owner as defined by RCW.19.28.261 (1) Owner will occupy the structu two years after this electrical permit is finalized. (2) Owner Is required to hire an electrical contractor if above said property is for sale, rent or lease. After reading the.ahove statement i,herehy certify that i am the owner above named property or a licensed electrical contractor 1 am making the electrical installation or alteration in compliance with the electrical laws, N.E.C. i Chapter 19 28, WAC, Chapter 296.468, The City of Port Angeles Municipal Code, and Utility Specifications. Signature o oer Oectri ontr or or electrical administrator ❑ Cash ❑ I 1. 1C'A �id1F ` _ redit Ca; tt Q,.'_ T/T d TTLbZTb 01 b2b92Sb 30I()d3S 0Ii'1103-13 WMIJ 462 80 9002-22-NUr Si,=nature of owner or Electrical Contractor X Date ELECTRICAL PERMIT v CITY OF PORT ANGELES 360-417-4735 Application Number 09 00001259 Date 12/04/09 Application pin number 846214 Property Address 114 W 10TH ST ASSESSOR PARCEL NUMBER 06 30 00 0 3 2720 0000 Application type description ELECTRICAL ONLY Subdivision Name Property Use Property Zoning RS7 RESDNTL SINGLE FAMILY Application valuation 0 Application desc 10 KW furnace t stat Owner Contractor .lei DOYLE DENNIS MICHAEL PENINSULA HEAT INC 1233 E 3RD ST 782 KITCHEN DICK RD PORT ANGELES WA 983627818 SEQUIM WA 98382 (360) 681 3333 Permit ELECTRICAL NEW RESIDENTIAL Additional dumb Permit pin number 157610 Permit Fee 43 75 Plan Check Fee 00 Issue Date 12/04/09 Valuation 0 Expiration Date 6/02/10 Qty Unit Charge Per Extension 1 00 43 7500 ECH EL LVT THERMOSTAT 43 75 Fee Charged Paid Credited Due summary Permit Fee Total 43 75 43 75 00 00 ( (� Plan Check Total 00 00 00 00 v' Grand Total 43 75 43 75 00 00 INSPECTION TYPE DATE RESULTS INSPECTOR. DITCH SERVICE ROUGH IN FINAL COMMENTS Si,=nature of owner or Electrical Contractor X Date 12/03/09 09 58 FAX 3606812086qu eat 02 oil""E" City of Port Angeles Permit Application Bunding D'mslonlEWetrical Inspeedons 321 East Fifth Street- P.O. Box 1150 Port Angeles Washington, 98362 Ph: (360) 417.4735 Fax. (360) W-4711 Date: 1.712-,& :-I- & 2 Single Family Dwelling _ Mulli-Family or Commercial' Commercial Addition / Alteration I Remodel l Repair' Plan Review May;Be R uired, Pease Complete Electrical Plan Review IntOrmatinn Sheet Job Address:- Bullding Square Footage: Desaxiplion of above %� Pl r� �lJZ2 G717 4`1.7 Owner Info ation `` -- 00 N_ Contractor Irprmation Name: f �li ufi . �/11G Name: ! r n4 Mailin dress i f _ Mailing dress: -- City State: p: City ►l�wt State Zap. Phone- Fa>c Phone:fal;;133, 6 Fax-- 0� g License # 1 Exp - license # I a Unit Cflar�e To it Muttiglied'by Vnit Charnel $ 9375 $ ServicelFeeder 200 Amp. $113.75 $ ServitzFeeder 201.400 Amp. 5160.00 $ Service/Feeder 401.600 Amp. $205.00 $ Ser Am Feeder 601-1000 Amp. $291.25 $ . Service /Feeder over 1000 Amp. 5 2.00 $ 9rw dr CkvA W/ Service Feeder S 57.50 $ Branch Circuit W/O Service Feeder $ 2.00 $ Each Additional Brandt Moult 5.72:50 $ Temp. Servical Feeder 200 Amp. 5 8625 $ Temp. SeivloelFeeder 201400 Amp. $11625 $ Temp. ServicelFeeder401-600 Amp. $13125 $ Temp. SerAcdFeeder601-1000Amp. $,75.00 3 Portal to Portal Hourly S 69.00 $ SigaDAM Lighting S 75.00 $_ Signal CuctW Limited Energy Commercial $ .50.00 $ Signal OWY railed Energy -1 & 2 Family Dwelling S-50-00 $ Signal Cimulll Limited Energy - MuIG-Family Dwelling 5 93.75 $ Manufactured Home Conneclon $ 80.00 $ Renewable Electrical Energy - SKVA System or Less S 86,25 S First 1300 Square FL S 27.50 $ Each Additional 500 Square Ft. or Portion of S 57.50 $ Each Outbuilding or Detadted Garage $ 86Z $ Each Swimming Pail or Hat Tub $ 43.75 $ Ll -7s Thermostat $ Total Owner as dellned by RCW.19.28.261: (1) Owner wf# occupy 6)s structure for two yoars arfter mis dw&kal pop* l4 finafind. (2) Ownpr Is reqube0 0o hba an slieftaf aon&adorif above said propertyis Dorsal& font orkm After reading the above ststament, I hereby c*Mfy that I am the owner of the above named property or a licensed electrical conbadpr: I am making the electrical instaMon or alteration in compllanco with the electrical Laws, N.E.C. RCW. Chapter 1928, WAC. Chapter 29648, The CUy of PortAngelee Munldpal Code, and Utility Specifications. Signahm of owner, electrical tractor or electrical administrator Cl Cash ❑ Check ` f X CG Mata: /2-4ZP2 "It Card # _ /i N Z. e PREPARED 11/16/09 9 27 49 INSPECTION TICKET PAGE 1 CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 11/16/09 ADDRESS 114 W 10TH ST SUBDIV TENANT NBR DENNIS MICHAEL DOYLE CONTRACTOR PHONE OWNER DENNIS MICHAEL DOYLE PHONE (360) 457 1902 PARCEL 06 30 00 0 3 2720 0000 APPL NUMBER 09 00000408 RES NEW SFR PERMIT BPR 00 BUILDING PERMIT RESIDENTIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS BL1 01 6/16/09 JLL BLDG FOUNDATION FOOTING TIME O1 00 6/16/09 AP June 16 2009 9 18 33 AM 1pangrle LARRY 775 1924 FOOTING REBAR AFTERNOON June 16 2009 4 59 43 PM jlierly BL2 01 7/01/09 JLL BLDG FOUNDATION STEM WALL TIME O1 00 7/13/09 AP July 1 2009 8 19 44 AM 1pangrle LARRY 775 1924 STEMWALL AFTERNOON July 13 2009 3 49 58 PM jlierly BLFD O1 7/09/09 JLL BLDG FOUNDATION DRAINAGE 7/09/09 AP July 9 2009 10 02 17 AM permits July 9 2009 4 54 05 PM jlierly BL3 01 7/22/09 JLL BLDG FRAMING TIME 02 30 7/22/09 DA July 21 2009 3 07 26 PM 1pangrle LARRY 775 1924 UNDERFLOOR GIRDER JOIST PLEASE INSPECT AFTER 2 30 PM July 22 2009 4 12 20 PM jlierly not complete recall when ready/jll BL3 02 7/24/09 JLL BLDG FRAMING TIME 03 30 7/24/09 AP July 23 2009 1 22 43 PM 1pangrle LARRY 775 1924 'BEAM & JOIST LATE AFTERNOON INSPECTION July 24 2009 4 13 54 PM jlierly BL3 03 11/16/09 JLL L� BLDG FRAMING TIME O1 00 November 16 2009 9 15 35 AM 1pangrle LARRY DOYLE 775 1924 FRAMING AFTERNOON PERMIT PL 00 PLUMBING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS PL6 01 5/29/09 JLL PLUMBING WATER SUPPLY 6/18/09 AP May 29 2009 2 14 57 PM 1pangrle LARRY 775 1924 WATER SUPPLY LINE METER TO BUILDING June 18 2009 9 34 58 AM jlierly PL2 01 11/16/09 PLUMBING ROUGH IN TIME O1 00 November 16 2009 9 16 19 AM 1pangrle CONTINUED ONTO NEXT PAGE PREPARED 7/24/09 8 12 53 INSPECTION TICKET PAGE 3 CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 7/24/09 ADDRESS 114 W 10TH ST SUBDIV TENANT NBR DENNIS MICHAEL DOYLE CONTRACTOR PHONE OWNER DENNIS MICHAEL DOYLE PHONE (360) 457 1902 PARCEL 06 30 00 0 3 2720 0000 APPL NUMBER 09 00000408 RES NEW SFR PERMIT BPR 00 BUILDING PERMIT RESIDEN'T'IAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS BL1 01 6/16/09 JLL BLDG FOUNDATION FOOTING TIME 01 00 6/16/09 AP June 16 2009 9 18 33 AM 1pangrle LARRY 775 1924 FOOTING REBAR AFTERNOON Jure 16 2009 4 59 43 PM jlierly BL2 01 7/01/09 JLL BLDG FOUNDATION STEM WALL TIME 01 00 7/13/09 AP Tuly 1 2009 8 19 44 AM 1pangrle LARRY 775 1924 STEMWALL AFTERNOON July 13 2009 3 49 58 PM jlierly BLFD 01 7/09/09 JLL BLDG FOUNDATION DRAINAGE 7/09/09 AP July 9 2009 0 02 17 AM permits July 9 2009 4 54 05 PM jlierly BL3 01 7/22/09 JLL BLDG FRAMING TIME 02 30 7/22/09 DA July 21 2009 3 07 26 PM 1pangrle LARRY 775 1924 'UNDERFLOOR GIRDER JOIST' PLEASE INSPECT AFTER 2 30 PM July 22 2009 4 12 20 PM jlierly not complete recall when ready/jll BL3 02 7/24/09 L BLDG FRAMING TIME 03 30 L ! July 23 2009 1 22 43 PM 1pangrle LARRY 775 1924 'BEAM & JOIST LATE AFTERNOON INSPECTION COMMENTS AND NOTES PREPARED 7/22/09 8 18 01 INSPECTION TICKET PAGE 9 CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 7/22/09 ADDRESS 114 W 10TH ST SUBDIV TENANT NBR DENNIS MICHAEL DOYLE CONTRACTOR PHONE OWNER DENNIS MICHAEL DOYLE PHONE (360) 457 1902 PARCEL 06 30 00 0 3 2720 0000 APPL NUMBER 09 00000408 RES NEW SFR PERMIT BPR 00 BUILDING PERMIT RESIDENTIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS BL1 01 6/16/09 JLL BLDG FOUNDATION FOOTING TIME O1 00 6/16/09 AP June 16 2009 9 18 33 AM 1pangrle LARRY 775 1924 FOOTING REBAR AFTERNOON June 16 2009 4 59 43 PM jlierly BL2 01 7/01/09 JLL BLDG FOUNDATION STEM WALL TIME O1 00 7/13/09 AP Tuly 1 2009 8 19 44 AM 1pangrle LARRY 775 1924 STEMWALL AFTERNOON July 13 2009 3 49 58 PM jlierly BLFD O1 7/09/09 JLL BLDG FOUNDATION DRAINAGE 7/09/09 AP July 9 2009 10 02 17 AM permits ^� July 9 2009 4 54 05 PM jlierly BL3 01 7/22/09 BLDG FRAMING TIME 02 30 ,r July 2 2009 3 07 26 PM 1pangrle LARRY 775 1924 UNDERFLOOR GIRDER JOIST PLEASE INSPECT AFTER 2 30 PM COMMENTS AND NOTES PREPARED 7/09/09 10 59 48 INSPECTION TICKET PAGE 4 CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 7/09/09 ADDRESS 114 W 10TH ST SUBDIV TENANT NBR DENNIS MICHAEL DOYLE CONTRACTOR PHONE OWNER DENNIS MICHAEL DOYLE PHONE (360) 457 1902 PARCEL 06 30 00 0 3 2720 0000 APPL NUMBER 09 00000408 RES NEW SFR PERMIT BPR 00 BUILDING PERMIT RESIDENTIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS BL1 01 6/16/09 JLL BLDG FOUNDATION FOOTING TIME O1 00 6/16/09 AP June 16 2009 9 18 33 AM 1pangrle LARRY 775 1924 FOOTING REBAR AFTERNOON June 16 2009 4 59 43 PM jlierly BL2 01 7/01/09 JLL BLDG FOUNDATION STEM WALL TIME O1 00 July 1 2009 8 19 44 AM 1pangrle LARRY 775 1924 STEMWALL AFTERNOON BLFD O1 7/09/09 JLLO BLDG FOUNDATION DRAINAGE July 9 2009 10 02 17 AM permits COMMENTS AND NOTES PREPARED 7/01/09 8 21 32 INSPECTION TICKET PAGE 2 CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 7/01/09 ADDRESS 114 W 10TH ST SUBDIV TENANT NBR DENNIS MICHAEL DOYLE CONTRACTOR PHONE OWNER DENNIS MICHAEL DOYLE PHONE (360) 457 1902 PARCEL 06 30 00 0 3 2720 0000 APPL NUMBER 09 00000408 RES NEW SFR PERMIT BPR 00 BUILDING PERMIT RESIDENTIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS BL1 01 6/16/09 JLL BLDG FOUNDATION FOOTING TIME O1 00 6/16/09 AP June 16 2009 9 18 33 AM 1pangrle LARRY 775 1924 FOOTING REBAR AFTERNOON June 16 2009 4 59 43 PM jlierly BL2 01 7/01/09 J BLDG FOUNDATION STEM WALL TIME O1 00 July 1 2009 8 19 44 AM 1pangrle LARRY 775 1924 STEMWALL AFTERNOON COMMENTS AND NOTES PREPARED 6/16/09 9 25 22 CITY OF PORT ANGELES ADDRESS 114 W 10TH ST TENANT NBR DENNIS MICHAEL DOYLE CONTRACTOR OWNER DENNIS MICHAEL DOYLE PARCEL 06 30 00 0 3 2720 0000 APPL NUMBER 09 00000408 RES NEW SFR INSPECTION TICKET INSPECTOR JAMES LIERLY SUBDIV PHONE PHONE (360) 457 1902 PERMIT BPR 00 BUILDING PERMIT RESIDENTIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS BL1 01 6/16/09 L BLDG FOUNDATION FOOTING TIME O1 00 4 June 16 2009 9 18 33 AM 1pangrle LARRY 775 1924 FOOTING REBAR AFTERNOON COMMENTS AND NOTES PAGE 6 DATE 6/16/09 Application Number Application pin number Property Address ASSESSOR PARCEL NUMBER Tenant nbr name Application type description Subdivision Name Property Use Property Zoning Application valuation CITY OF PORT ANGELES PUBLIC WORKS & UTILITIES 321 EAST 5TH STREET PORT ANGELES, WA 98362 09 00000408 Date 6/04/09 766936 114 W 10TH ST 06 30 00 0 3 2720 0000 DENNIS MICHAEL DOYLE RES NEW SFR RS7 RESDNTL SINGLE FAMILY 146952 Application desc 1 536 SF SFR/528 SF ATT GARAGE/ 46 SF CVRD PORCH Owner Contractor DENNIS MICHAEL DOYLE OWNER 1233 E 3RD ST PORT ANGELES WA 98362 (360) 457 1902 Structure Information 000 000 1 536 SF SFR/528 SF GRG/46 SF CVD PRCH Other struct info TOTAL % LOT COVERAGE 30 10 CONSTRUCTION TYPE VB FIRE SPRINKLERS REQUIRED NO NUMBER OF STORIES 1 00 LOT SIZE 7000 00 PROPOSED LOT COVERAGE 2110 00 TOTAL LOT COVERAGE 2110 00 NUMBER OF UNITS 1 00 Permit RIGHT OF WAY Additional desc WEEP HOLE THROUGH CURB Permit pin number 147579 Permit Fee 50 00 Plan Check Fee 00 Issue Date 6/04/09 Valuation 146952 Expiration Date 12/01/09 Qty Unit Charge Per Extension 1 00 50 0000 ECH RIGHT OF WAY PERMIT 50 00 Special Notes and Comments Address numbers shall be plainly visible from the street Address numbers shall be a minimum of six inches high and be of contrasting color from the background May 13 2009 10 41 00 AM sroberds The proposal will result in construction a new sfr in the RS 7 zone with 30% lot coverage and 46% site coverage Demo permit 09 382 will remove existing nonconforming shed No land use issues are anticipated May 12 2009 3 46 53 PM banders Brian 417 4708 Service location at the southeast corner of garage with a 5 foot mast required for clearance over communication lines Reconnect to existing sewer lateral at property line an inspection of existing sewer lateral will be required A new Separate Permits are required for electrical work, SEPA, Shoreline ESA, utilities private and public improvements This permit becomes null and void if work or construction authorized is not commenced within 180 days if construction or work is suspended or abandoned for a period of 180 days after the work as commenced or if required inspections have not been requested within 180 days from the last inspection I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate cancel the provisions of any state or local law regulating construction or the performance of construction - &/'/'/P Signa re of Contracto or'Aut/�ed Agent Da� Signature of Owner (if owner is builder) Date T \Policies\110215 [10/081 PERMIT INSPECTION RECORD a CALL 417-4831 FOR UTILITY INSPECTIONS PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED POST PERMIT INA CONSPICUOUS LOCATION KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE INSPECTION TYPE DATE I ACCEPTED COMMENTS YES I NO I PW UTILITIES (Engineering Division) WATERLINE / METER SEWER CONNECTION SANITARY STORM SITE DRAINAGE SITE EROSION CONTROL PARKING SIDEWALK CURB & GUTTER DRIVEWAY APPROACH BACK-FLOW DEVICE RESIDENTIAL CONSTRUCTION R W / PW/ ENGINEERING FIRE PLANNING DEPT BUILDING T\Policies\11021 [10/081 FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE DATE YES NO COMMERCIAL DATE ACCEPTED YES NO CONSTRUCTION R.W 417-4831 PW / ENGINEERING 417-4653 FIRE DEPT 417-4750 PLANNING DEPT 417-4815 BUILDING DATE ACCEPTED YES NO CITY OF PORT ANGELES PUBLIC WORKS & UTILITIES 321 EAST 5TH STREET PORT ANGELES WA 98362 Page 2 Application Number 09 00000408 Date 6/04/09 Application pin number 766936 Special Notes and Comments connection at main may be required Sanitary sewer connection inspection is required by Public works prior to back fill of ditch 24 hour advance notice is required Building water line connection to existing water meter requires a Building Division inspection prior to back fill of ditch May 18 2009 10 48 54 AM rbecker If lawn sprinkler system is installed you will need to install a double check backflow assembly If you you have any questions contact Ron Becker at (360)417 4886 or e mail me at rbeckeratcityofpa us Other Fees STATE SURCHARGE Fee summary Charged Paid Credited Permit Fee Total 50 00 50 00 00 Plan Check Total 00 00 00 Other Fee Total 4 50 4 50 00 Grand Total 54 50 54 50 00 Due 4 50 00 00 00 00 Separate Permits are required for electrical work, SEPA, Shoreline ESA, utilities private and public improvements This permit becomes null and void if work or construction authorized is not commenced within 180 days if construction or work is suspended or abandoned for a period of 180 days after the work as commenced or if required inspections have not been requested within 180 days from the last inspection I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction Signature of Contractor or Authorized Agent T \Policies\110215 [10/081 Date Signature of Owner (if owner is builder) Date PERMIT INSPECTION RECORD I CALL 417-4831 FOR UTILITY INSPECTIONS PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. ITIS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT IN A CONSPICUOUS LOCATION KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE INSPECTION TYPE PW UTILITIES (Engineering Division) WATERLINE / METER SEWER CONNECTION SANITARY STORM SITE DRAINAGE SITE EROSION CONTROL PARKING SIDEWALK CURB & GUTTER DRIVEWAY APPROACH BACK-FLOW DEVICE RESIDENTIAL CONSTRUCTION R.W / PW/ ENGINEERING FIRE PLANNING DEPT BUILDING T\Policies\11031 [10/08] DATEI ACCEPTED COMMENTS I` YES I NO FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE DATE YES NO COMMERCIAL DATE ACCEPTED YES NO CONSTRUCTION R. W 417-4831 PW / ENGINEERING 417-4653 FIRE DEPT 417-4750 PLANNING DEPT 417-4815 BUILDING ACCEPTED YES NO PREPARED 5/29/09 14 16 02 INSPECTION TICKET PAGE 1 CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 5/29/09 ADDRESS 114 W 10TH ST SUBDIV TENANT NBR DENNIS MICHAEL DOYLE CONTRACTOR PHONE OWNER DENNIS MICHAEL DOYLE PHONE (360) 457 1902 PARCEL 06 30 00 0 3 2720 0000 APPL NUMBER 09 00000408 RES NEW SFR PERMIT PL 00 PLUMBING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS PL6 01 5/29/09 JLLL /^1 PLUMBING WATER SUPPLY May 29 2009 2 14 57 PM 1pangrle LARRY 775 1924 WATER SUPPLY LINE METER TO BUILDING COMMENTS AND NOTES PREPARED 5/22/09 8 41 05 INSPECTION TICKET PAGE 4 CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 5/22/09 ADDRESS 114 W 10TH ST SUBDIV TENANT NBR DENNIS MICHAEL DOYLE CONTRACTOR PHONE OWNER DENNIS MICHAEL DOYLE PHONE (360) 457 1902 PARCEL 06 30 00 0 3 2720 0000 APPL NUMBER 09 00000382 DEMOLITION PERMIT DEMO 00 DEMOLITION REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS BL99 01 5/22/09 BLDG FINAL May 21 2009 4 47 17 PM 1pangrle LARRY DOYLE 775 1924 BLDG FINAL DEMOLITION OF SHED COMMENTS AND NOTES Application Number Application pin number Property Address ASSESSOR PARCEL NUMBER Tenant nbr name Application type description Subdivision Name Property Use Property Zoning Application valuation CITY OF PORT ANGELES PUBLIC WORKS & UTILITIES 321 EAST 5TH STREET PORT ANGELES, WA 98362 09 00000408 Date 5/21/09 766936 114 W 10TH ST 06 30 00 0 3 2720 0000 DENNIS MICHAEL DOYLE RES NEW SFR RS7 RESDNTL SINGLE FAMILY 146952 Application desc 1 536 SF SFR/528 SF ATT GARAGE/ 46 SF CVRD PORCH Owner Contractor DENNIS MICHAEL DOYLE OWNER 1233 E 3RD ST PORT ANGELES WA 98362 (360) 457 1902 Structure Information 000 000 1 536 SF SFR/528 SF GRG/46 SF CVD PRCH Other struct info TOTAL % LOT COVERAGE 30 10 CONSTRUCTION TYPE VB FIRE SPRINKLERS REQUIRED NO NUMBER OF STORIES 1 00 LOT SIZE 7000 00 PROPOSED LOT COVERAGE 2110 00 TOTAL LOT COVERAGE 2110 00 NUMBER OF UNITS 1 00 Permit SANITARY SEWER HOOK UP Additional desc Permit pin number 145789 Permit Fee 135 00 Plan Check Fee 00 Issue Date 5/21/09 Valuation 146952 Expiration Date 11/17/09 Qty Unit Charge Per Extension 1 00 135 0000 EA SAN SEW RECON 135 00 Special Notes and Comments Address numbers shall be plainly visible from the street Address numbers shall be a minimum of six inches high and be of contrasting color from the background May 13 2009 10 41 00 AM sroberds The proposal will result in construction a new sfr in the RS 7 zone with 30%- lot coverage and 46W site coverage Demo permit 09 382 will remove existing nonconforming shed No land use issues are anticipated May 12 2009 3 46 53 PM handers Brian 417 4708 Service location at the southeast corner of garage with a 5 foot mast required for clearance over communication lines Reconnect to existing sewer lateral at property line an inspection of existing sewer lateral will be required A new Separate Permits are required for electrical work, SEPA, Shoreline ESA, utilities private and public improvements This permit becomes null and void if work or construction authorized is not commenced within 180 days if construction or work is suspended or abandoned for a period of 180 days after the work as commenced or if required inspections have not been requested within 180 days from the last inspection I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give autho�rlty to violate or cancel the provisions of any state or local law regulating construction or the performance of constwGtion / \ /I WonffactA er t Date Si nature of Owner if owner is builder Date Sig uthorized g g ( ) T-\Policies\1102 15 [10/081 PERMIT INSPECTION RECORD y CALL 417-4831 FOR UTILITY INSPECTIONS PLEASE PROVIDE A MINIMUM( 24 HOUR NOTICE. ITIS UNLA141FUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED POST PERMIT INA CONSPICUOUS LOCATION KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE INSPECTION TYPEI DATE ACCEPTED I COMMENTS YES I NO PW UTILITIES (Engineering Division) WATERLINE / METER SEWER CONNECTION SANITARY STORM SITE DRAINAGE SITE EROSION CONTROL PARKING SIDEWALK CURB & GUTTER DRIVEWAY APPROACH BACK-FLOW DEVICE I FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE RESIDENTIAL DATE YES NO COMMERCIAL CONSTRUCTION R W / PW/ CONSTRUCTION R. W ENGINEERING 417-4831 PW / ENGINEERING FIRE 417-4653 FIRE DEPT PLANNING DEPT 417-4750 PLANNING DEPT BUILDING 417-4815 I BUILDING T\Policies\1102 15 [10/081 DATE ACCEPTED YES NO CITY OF PORT ANGELES PUBLIC WORKS & UTILITIES 321 EAST 5TH STREET PORT ANGELES, WA 98362 Page 2 Application Number 09 00000408 Date 5/21/09 Application pin number 766936 Special Notes and Comments connection at main may be required Sanitary sewer connection inspection is required by Public Works prior to back fill of ditch 24 hour advance notice is required Building water line connection to existing water meter requires a Building Division inspection prior to back fill of ditch May 18 2009 10 48 54 AM rbecker If lawn sprinkler system is installed you will need to install a double check backflow assembly If you you have any questions contact Ron Becker at (360)417 4886 or e mail me at rbeckeratcityofpa us Other Fees STATE SURCHARGE Fee summary Charged Paid Credited Permit Fee Total 135 00 135 00 00 Plan Check Total 00 00 00 Other Fee Total 4 50 4 50 00 Grand Total 139 50 139 50 00 Due 4 50 00 00 00 00 Separate Permits are required for electrical work, SEPA, Shoreline ESA, utilities private and public improvements This permit becomes null and void if work or construction authorized is not commenced within 180 days if construction or work is suspended or abandoned for a period of 180 days after the work as commenced, or if required inspections have not been requested within 180 days from the last inspection I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction Signature of Contractor or Authorized Agent T'\Po6cies\1102 15 [10/081 Date Signature of Owner (if owner is builder) Date PERMIT INSPECTION RECORD CALL 417-4831 FOR UTILITY INSPECTIONS PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. ITIS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED POST PERMIT INA CONSPICUOUS LOCATION tl KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE INSPECTION TYPEI DATE I ACCEPTED COMMENTS I` YES I NO PW UTILITIES (Engineering Division) WATERLINE / METER SEWER CONNECTION I` SANITARY STORM SITE DRAINAGE SITE EROSION CONTROL PARKING SIDEWALK CURB & GUTTER I DRIVEWAY APPROACH BACK-FLOW DEVICE I` FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE I RESIDENTIAL DATE YES NO COMMERCIAL DATE ACCEPTED Y ES NO CONSTRUCTION R.W /PW/ CONSTRUCTION R.W ENGINEERING 417-4831 PW / ENGINEERING FIRE 417-4653 FIRE DEPT PLANNING DEPT 417-4750 PLANNING DEPT BUILDING 417-4815 BUILDING T \Policies\110' 15 [10/081 CITY OF PORT ANGELES o ��1 DEPARTMENT OF COMMUNITY & ECONOMIC DEVELOPMENT BUILDING DIVISION 321 EAST 5TH STREET PORT ANGELES WA 98362 Application Number Application pin number Property Address ASSESSOR PARCEL NUMBER Tenant nbr name Application type description Subdivision Name Property Use Property Zoning Application valuation 09 00000408 Date 5/21/09 766936 114 W 10TH ST 06 30 00 0 3 2720 0000 DENNIS MICHAEL DOYLE RES NEW SFR RS7 RESDNTL SINGLE FAMILY 146952 Application desc 1 536 SF SFR/528 SF ATT GARAGE/ 46 SF CVRD PORCH Owner Contractor DENNIS MICHAEL DOYLE OWNER 1233 E 3RD ST PORT ANGELES WA 98362 (360) 457 1902 Structure Information 000 000 1 536 SF SFR/528 SF GRG/46 SF CVD PRCH Other struct info TOTAL % LOT COVERAGE 30 10 CONSTRUCTION TYPE VB FIRE SPRINKLERS REQUIRED NO NUMBER OF STORIES 1 00 LOT SIZE 7000 00 PROPOSED LOT COVERAGE 2110 00 TOTAL LOT COVERAGE 2110 00 NUMBER OF UNITS 1 00 Permit BUILDING PERMIT RESIDENTIAL Additional desc 1 536 SF SFR & 528 SF GARAGE Permit pin number 145458 Permit Fee 1283 45 Plan Check Fee 834 24 Issue Date 5/21/09 Valuation 146952 Expiration Date 11/17/09 Qty Unit Charge Per Extension BASE FEE 1020 25 47 00 5 6000 THOU BL 100 001 500K (5 60 PER K) 263 20 Permit MECHANICAL PERMIT Additional desc Permit pin number 145466 Permit Fee 104 45 Plan Check Fee 00 Issue Date 5/21/09 Valuation 0 Expiration Date 11/17/09 Qty Unit Charge Per Extension BASE FEE 50 00 1 00 14 8000 EA ME FURN/HP/FAU < OR = 5 TON 14 80 4 00 7 2500 EA ME VENT FAN (SINGLE DUCT) 29 00 1 00 10 6500 EA ME STOVE/FIREPLACE/MISC APP 10 65 fr 5 -19 -gyp Separate Permits are required for electrical work, SEPA, Shoreline, ESA, utilities, private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned for a period of 180 days after the work has commenced, or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of an), state or local law regulating construction or the performance of c ruc n. ,S --;.I-09 l©yl-F Date Print Name Sig ya�i roof C <ntrackr o u orized Agent Signature of Owner (if owner is builder) T:FonnsBuilding Division/Building Permit !� N BUILDING PERMIT INSPECTION RECORD — PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS — Building Inspections 417-4815 Electrical Inspections 417-4735 Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886 IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE. Inspection Type I Date FOUNDATION Footings Stemwall Foundation Drainage / Downspouts Piers Post Holes (Pole Bldgs.) PLUMBING Under Floor / Slab Rough -In Water Line (Meter to Bldg) Gas Line Back Flow/ Water AIR SEAL. Walls Ceiling FRAMING Joists / Girders / Under Floor Shear Wall / Hold Downs Walls / Roof / Ceiling Drywall (Interior Braced Panel Only) T -Bar INSULATION Slab Wall / Floor/ Ceiling MECHANICAL. Heat Pump / Furnace / FAU / Ducts Rough -In Gas Line Wood Stove / Pellet / Chimney Commercial Hood / Ducts MANUFACTURED HOMES Footing / Slab Blocking & Hold Downs Skirting PLANNING DEPT Separate Permit #s Parking / Lighting Landscaping Accepted By I I FINAL Date FINAL Date SEPA. ESA. SHORELINE. Comments Accepted by Accepted by FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/ USE Inspection Type Date Accepted By Electrical 417-4735 Construction R.W PW / Engineering 417-4831 Fire 417-4653 Planning 417-4750 Building 417-4815 T Forms/Building Division/Building Permit CITY OF PORT ANGELES DEPARTMENT OF COMMUNITY & ECONOMIC DEVELOPMENT BUILDING DIVISION W/ _-/ 321 EAST 5TH STREET PORT ANGELES WA 98362 Application Number 09 00000408 Application pin number 766936 Permit PLUMBING PERMIT Additional desc Permit pin number 145474 Permit Fee 163 00 Plan Check Fee Issue Date 5/21/09 Valuation Expiration Date 11/17/09 Qty Unit Charge Per Page 2 Date 5/21/09 Special Notes and Comments Address numbers shall be plainly visible from the street Address numbers shall be a minimum of six inches high and be of contrasting color from the background May 13 2009 10 41 00 AM sroberds The proposal will result in construction a new sfr in the RS 7 zone with 30% lot coverage and 46% site coverage Demo permit 09 382 will remove existing nonconforming shed No land use issues are anticipated May 12 2009 3 46 53 PM banders Brian 417 4708 Service location at the southeast corner of garage with a 5 foot mast required for clearance over communication lines Reconnect to existing sewer lateral at property line an inspection of existing sewer lateral will be required A new connection at main may be required Sanitary sewer connection inspection is required by Public Works prior to back fill of ditch 24 hour advance notice is required Building water line connection to existing water meter requires a Building Division inspection prior to back fill of ditch May 18 2009 10 48 54 AM rbecker If lawn sprinkler system is installed you will need to install a double check backflow assembly If you you have any questions contact Ron Becker at (360)417 4886 or e mail me at rbeckeratcityofpa us Other Fees STATE SURCHARGE 00 0 Extension 50 00 84 00 7 00 15 00 7 00 Fee summary Charged Paid Credited Due 4 50 Permit Fee Total 1550 90 1550 90 00 00 Plan Check Total 834 24 834 24 00 00 Other Fee Total 4 50 4 50 00 00 Grand Total 2389 64 2389 64 00 00 Separate Permits are required for electrical work, SEPA, Shoreline, ESA, utilities, private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned for a period of 180 days after the work has commenced. or if required inspections have not been requested within 180 days from the last inspection I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. Date Print Name Signature of Contractor or Authorized Agent Signature of Owner (if owner is builder) T:FormsBuilding Division/Building Permit BASE FEE 12 00 7 0000 EA PL -PLUMBING TRAP 1 00 7 0000 EA PL -WATER LINE 1 00 15 0000 EA PL SEWER LINE 1 00 7 0000 EA PL WATER HEATER Page 2 Date 5/21/09 Special Notes and Comments Address numbers shall be plainly visible from the street Address numbers shall be a minimum of six inches high and be of contrasting color from the background May 13 2009 10 41 00 AM sroberds The proposal will result in construction a new sfr in the RS 7 zone with 30% lot coverage and 46% site coverage Demo permit 09 382 will remove existing nonconforming shed No land use issues are anticipated May 12 2009 3 46 53 PM banders Brian 417 4708 Service location at the southeast corner of garage with a 5 foot mast required for clearance over communication lines Reconnect to existing sewer lateral at property line an inspection of existing sewer lateral will be required A new connection at main may be required Sanitary sewer connection inspection is required by Public Works prior to back fill of ditch 24 hour advance notice is required Building water line connection to existing water meter requires a Building Division inspection prior to back fill of ditch May 18 2009 10 48 54 AM rbecker If lawn sprinkler system is installed you will need to install a double check backflow assembly If you you have any questions contact Ron Becker at (360)417 4886 or e mail me at rbeckeratcityofpa us Other Fees STATE SURCHARGE 00 0 Extension 50 00 84 00 7 00 15 00 7 00 Fee summary Charged Paid Credited Due 4 50 Permit Fee Total 1550 90 1550 90 00 00 Plan Check Total 834 24 834 24 00 00 Other Fee Total 4 50 4 50 00 00 Grand Total 2389 64 2389 64 00 00 Separate Permits are required for electrical work, SEPA, Shoreline, ESA, utilities, private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned for a period of 180 days after the work has commenced. or if required inspections have not been requested within 180 days from the last inspection I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. Date Print Name Signature of Contractor or Authorized Agent Signature of Owner (if owner is builder) T:FormsBuilding Division/Building Permit BUILDING PERMIT INSPECTION RECORD - PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS -- Building Inspections 417-4815 Electrical Inspections 417-4735 Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886 IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE. Inspection Type I Date I Accepted By I Comments FOUNDATION Footings W(a - ( 11 ALL I Stemwall 1*7 — I —0q Foundation Drainage / Downspouts 7-9-04 Piers Post Holes (Pole Bldgs.) PLUMBING Under Floor / Slab Rough -In I I(Q O q Water Line (Meter to Bldg) Gas Line Back Flow/ Water AIR SEAL. 12---7-- Oq Walls Ceiling FRAMING IZ-7- 0 q Joists / Girders / Under Floor Shear Wall / Hold Downs Walls / Roof / Ceiling Drywall (Interior Braced Panel Only) T -Bar I I � lila. I fq I FINAL Date 5- ` `- +0Accepted by .i L'L-^ I INSULATION. t .� I.p� ALU Slab Wall / Floor / Ceiling MECHANICAL. Heat Pump / Furnace / FAU / Ducts d- I_/0 J P,4< Rough -In Gas Line I Wood Stove / Pellet / Chimney I Commercial Hood / Ducts i3eam $ Ta— FINAL a - FINAL Date I _ I Accepted by MANUFACTURED HOMES Footing / Slab Blocking 8 Hold Downs I Skirting (PLANNING DEPT Separate Permit#s SEPA. (Parking / Lighting ESA. (Landscaping I I SHORELINE. FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/ USE Inspection Type I Date Accepted By Electrical 417-4735 Construction R W PW / Engineering 417-4831 Fire 417-4653 Planning 417-4750 Building 417-4815 -vq-10 (ice T.Forms/Building Division/Building Permit V T _elv- Geo& 1. � e, Ho.. .... �. .. � q N116 �v� 3 eN u ry) / C)630 0003 Z -72Z <F i Role Type: Asse,� w- ave.:Yfl Group codes: (SANDY) - r I: • c, aa4}� a 441 ...,n. 'w='6 PraPertY:'In f6rmati .: ...Dwner Nm ae: -x ( + 'PID 01241 :DENNYS=MICHAEL f,?A-n;gs L 327 :BL, N06 00 0 61 dfl' 'Tax Arta :OOID ;Nbadt:10955130" Fres�§mwf�. i- Land: '$56;25D Current•Use:$0 r'd.> ..:,nom...._ �.. -.-n- •. -a ,w�'`:. Mkt; $57;25tr Appraised: :$57;250' ,; • r, ':'b( Living::0 'PricOSQ'FF 40 Fr en .. - - - .. ., a -• - _ .ImpF$0. Year; Land: $0= fr°" Mx Intel: $U {: situs "" . _= 114VEST 10T14 STREET PORT ANGELES, AWA 96362 ��f ':�i «:e_.�?21,��.",•i�''�,,.�,.�a ., �' ` z �:I.�':�= >1'�.J?3,"._-x;W.ra;:s..:sm�Yar-,,.. r:..>za•_n>„yyr � r_�+ra,,;,.n;.:.. ., �;R a ^dad r• m ,i Legal Description Abstract/Subdivision... ... _. - _ 'Area:=&percentages a Qescription: Acreage: - A',t .327@oc-Effective`Sat: ' 0.1600 pry '• `' .rf✓" ''.„ 'TracVLot: '_'��.__._.—._____. —- 'CondD.Re cents a --------- - - i; -- 3 9 0.0000000000% i�,w,l.Additional 'LegeP:.-...... LZ Mete -Mete and Bounds:# 1'4'� 7ifIIP,�II i,u - other - LQT;=3'�'8L"c327'`.-.`."`F .F > r UDI,Child:� ' Auto Build Legal -" , .Legal Description "., �- - .A55ESSORCOUl�.I' ._. ,._,., . '.... I ��a,�POr PNury) o00 0003 2-72q In- k 4�0 A -'Clahammo: i PAC 0-0 OPPraliet X q. -A I 4"L ME— ftbi vft- MACS-9 7�.74ppriilwljEnilronm�nt-�,.D R 6 A... ..... . ... =Awl SUE ow a r Pi.PerN. Infor7oamp 'D4ervotie —S..e r Is M t t.I• 4:8L":827 A 81242 rLf2T i'd - a j- bKd I- ie Trice/�;q. uvim'd ft: iq' 1 . . ii Fr 4; + 41 PORTANGELE.S, WA498362, am: mww Lm b Scripto. 'j4 Abs&,a#/Subdi moria escription: —6 e 0.1600 •Plock::327 :Fffective.size: 0.1600 t. TracVLbP .4 §ondo:Permntida ..Boo&�ge iL , 40A Adolitionallitigal .-L 2 7 m 6lete5 and Bo ndl: Dther :LOT 4 BL 327 bi Child :r 'PLut6,6ui1d Legal lie Legal iptio . . . . . . . . . . NOTES Permit# C,.) e -A- a- ree-or,4A2J,i"--'&PCA---0 F 6"" Oj _���..�° (',��rzQ...�r'.� e -f � c:.e j h�,-E-- -�� ,�..� b eh� v,d. � � �'wc� �-,��.. ----------- 1, D o t4le ao-art- PN U M,5 _gkLI, it............................... . . . . . ............................................................................ , T Fon-ns/Buildtn6 Divisio -,,Notes Ow he e -177 - Y7 Application Number Application pin number Property Address ASSESSOR PARCEL NUMBER Tenant nbr name Application type description Subdivision Name Property Use Property Zoning Application valuation CITY OF PORT ANGELES FIRE DEPARTMENT PERMIT 321 East 5`h Street, Port Angeles, WA 98362 09 00000478 Date 836974 114 W 10TH ST 06 30 00 0 3 2720 0000 DENNIS MICHAEL DOYLE FIRE ABANDON TANK INSPECTION RS7 RESDNTL SINGLE FAMILY 0 Application desc REMOVE 500 GALLON UNDERGROUND OIL TANK Owner Contractor DENNIS MICHAEL DOYLE OWNER 1233 E 3RD ST PORT ANGELES WA 983627818 (360) 457 1902 Permit UNDERGROUND TANK RES Additional desc REMOVE 500 GAL TANK Permit pin number 146563 Permit Fee 15 00 Plan Check Fee Issue Date 5/20/09 Valuation Expiration Date 11/16/09 Qty Unit Charge Per BASE FEE Fee summary Charged Paid Permit Fee Total 15 00 15 00 Plan Check Total 00 00 Grand Total 15 00 15 00 5/20/09 00 0 Extension 15 00 Credited Due 00 00 00 00 00 00 This permit becomes null and void if work authorized is not commenced within 180 days, if work is suspended or abandoned for a period of 180 days afer the work has commenced, or if required inspections have not been requested with 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of recognized standards, laws and ordinances governing this type of work will be compled with whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any s e o lo c w regulating the work specified in the permit. SigTitu e ntracto r A rized Ag t Date Signature of Owner (if Owner is builder) Date FIRE PERMIT INSPECTION RECORD —9 Call 360-417-4655 for fire inspections Please provide a minimum 24-hour notice It is unlawful to cover insulate or conceal any work before inspected and accepted. Post permit in a conspicuous location. pq KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE Inspection Type FIRE SPRINKLER Underground piping hydrostatically tested Underground piping flushed Interior piping hydrostatically tested Interior piping inspection Dry system air tested at 40 psi (24 hours) Sprinkler final FIRE ALARM Rough -in inspection Alann final LP -GAS Underground piping inspection/pressure test Above ground piping inspection/pressure test Tank (container) inspection Date Passed Appliance inspection LP -gas final UNDERGROUND STORAGE TANK (UST) ABANDONMENT Removal of flammable/combustible liquids Tank appropriately abandoned Comments Completed by Contractor - Test #I Piping pressure test Time initiated Test #2 Piping pressure test Time initiated UST abandonment final 5-2.1-09 KC b PERMIT OTHER (specify) permit final GENERAL COMMENTS 2/15/00 psi O psi V) PREPARED 5/19/10 8 43 02 INSPECTION TICKET PAGE 2 CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 5/19/10 ADDRESS 114 W 10TH ST SUBDIV TENANT NBR DENNIS MICHAEL DOYLE CONTRACTOR PHONE OWNER DENNIS MICHAEL DOYLE PHONE (360) 457 1902 PARCEL 06 30 00 0 3 2720 0000 APPL NUMBER 09 00000408 RES NEW SFR REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS AFTERNOON December 7 2009 4 14 58 PM jlierly SLI 01 12/11/09 JLL BLDG INSULATION 12/11/09 AP December 10 2009 11 37 53 AM 1pangrle LARRY 775 1924 INSULATION December 11 2009 4 08 38 PM jlierly PW99 01 5/18/10 RV PUBLIC WORKS FINAL 5/18/10 AP May 18 2010 2 28 31 PM rvess May 18 2010 2 28 49 PM rvess BL99 01 5/19/10 L BLDG FINAL TIME 01 00 May 19 2010 8 28 55 AM 1pangrle LARRY DOYLE 775 1924 BUILDING FINAL AFTERNOON PERMIT ME 00 MECHANICAL PERMIT — REQUESTED INSP DESCRIPTION — — TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ME99 01 5/19/10 MECHANICAL FINAL TIME 01 00 May 19 2010 8 29 31 AM 1pangrle LARRY DOYLE 775 1924 MECHANICAL FINAL AFTERNOON PERMIT PL 00 PLUMBING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS PL6 01 5/29/09 JLL PLUMBING WATER SUPPLY 6/18/09 AP May 29 2009 2 14 57 PM 1pangrle LARRY 775 1924 WATER SUPPLY LINE METER TO BUILDING June 18 2009 9 34 58 AM jlierly PL2 01 11/16/09 JLL PLUMBING ROUGH IN TIME 01 00 11/16/09 AP November 16 2009 9 16 19 AM 1pangrle LARRY DOYLE 775 1924 ROUGH IN PLUMBING AFTERNOON November 16' 2009 4 22 31 PM jlierly PL99 01 5/19/10 L PLUMBING FINAL TIME 01 00 May 19 2010 8 29 55 AM 1pangrle LARRY DOYLE 775 1924 PLUMBING FINAL AFTERNOON COMMENTS AND NOTES ELECTRICAL PERMIT CITY OF PORT ANGELES 360-417-4735 Application Number 09 00000448 Date 5/15/09 Application pin number 436032 Property Address 114 W 10TH ST ASSESSOR PARCEL NUMBER 06 30 00 0 3 2720 0000 Application type description ELECTRICAL ONLY Subdivision Name Property Use Property Zoning RS7 RESDNTL SINGLE FAMILY Application valuation 0 Application desc Temp Service Owner Contractor DOYLE DENNIS MICHAEL ELECTRIC SERVICE 1233 E 3RD ST 82 DRAPER RD PORT ANGELES WA 983627818 PORT ANGELES WA 98362 �— (360) 452 6424 ter" Permit ELECTRICAL TEMPORARY SERVICE Additional desc Permit pin number 146043 Permit Fee 72 50 Plan Check Fee 00 Issue Date 5/15/09 Valuation 0 Expiration Date 11/11/09 Qty Unit Charge Per Extension 1 00 72 5000 ECH EL TEMP SRV 0 200 SRV FDR 72 50 Fee summary Charged Paid Credited Due Permit Fee Total 72 50 72 50 00 00 Plan Check Total 00 00 00 00 Grand Total 72 50 72 50 00 00 /n �1 INSPECTION TYPE DATE. RESULTS INSPECTOR. DITCH SERVICE 51-2o � r ROUGH IN FINAL -56 %5 iv TV COMMENTS Signature of owner or Electrical Contractor X Date JUL-4-2005 07 01A FROM ELECTRIC SERVICE who, ppNantloa Pik For. �r'i —M*Fo*wcwamw. Jab Addmm: ^ r- RARAcIXED MAY 5Q. f UGHT4 P � ofto"Offel OwWkd=Wm NOW M , At City: sma %A MA PharePhareIN 4'w. 4' mom. Rk $113.76 slew 3205.00 4291,7! 82.004SIM 4 m .9 no s as SOW $131M 41SO am 10 $50.0 3.75 's Koo suz szx $ Pip 8 = Emc— WA;' TO 4174711 P t,* 0021 jug f NZ comwo 142"GwWft &MV-SWA&AUmeals �FlarPbiModd ub momw6now"b6As f I Tw* sw Tsw sw s"ch Nwcft '! StrWidu j AMON" Fft am., Em*ft Eftftft Tw TO 4174711 P t,* 0021 jug f NZ comwo 142"GwWft &MV-SWA&AUmeals �FlarPbiModd ub momw6now"b6As f I i it) City of Bort Angeles Building Division 32' E 5t" St. � FILE .. Port Angeles, WA 93362 / PLAN REVIEW Items described here are only a guide to common questions and missed items during plan review and construction All codes must be complied with (Please read and follow each item ) SPECIAL NOTE. Check item #59 first to see if engineerinq will be needed because of lateral design issues. GENERAL. 1 Final grading of the property must be done prior to final inspection even if owner is doing required retaining walls Occupancy of the home will not be allowed until there are no slopes steeper than 2 units horizontal to 1 unit vertical or retaining walls are in place or an accepted soils report is submitted to the City If a soils report was required initially all requirements of the soils report must be accomplished prior to final inspection including submittal of all field reports 2. Acrylic stucco products have special requirements Verify such with the manufacturer Requirements may include tongue and groove foam board under finish control joints special backing boards (sometimes OSB is NOT allowed) self -furring or furred -out wire or fabric lath and sometimes installation by a certified installer (certified by the manufacturer) Verify any and all requirements of stucco siding or acrylic stucco products NO INSPECTION OF LATH OR STUCCO IS REQUIRED, BUT WRITTEN CERTIFICATION BY A MANUFACTURER'S CERTIFIED INSTALLER MUST BE LEFT AT THE JOB SITE UNTIL FINAL INSPECTION BY THE CITY 3 Inspection of shear wall nailing roof sheathing to blocking nailing and hold downs must be requested in addition to standard inspections and before such items are covered up Please specify shear nail roof nail or hold-down inspection when you request these they may be done simultaneously if ready 4 This plan is approved for OSB or plywood exterior wall sheathing only unless the approved plans at the time of permit issuance reflect other materials being used Any change to wall sheathing material after permit issuance must be submitted to the city for review prior to installation An additional plan review fee will be assessed 5 'Tyvek" or equal approved weather resistive barrier (15# felt is OK) required on the exterior side of all walls regardless of the type of siding used This includes garage walls gable portion of end walls and cripple walls (at stepped foundation conditions) Apply over exterior sheathing or over studs in single-wall construction T 1-11 or similar panel siding must have "Tyvek" or equal over the studs 6 Exterior windows and doors shall be flashed with approved materials and caulking Caulked trim material over the window or door flange is not an acceptable method 7 Overall dimensions of house plan must match site plan dimensions Verify any special requirements for buildings located close to property lines R302 T Building/Handouts/Residential Plan Review Guidelines (Rev 03-18-09) Page 1 of 8 V i). LIFE -SAFETY & MISC ITEMS 8. Sleeping rooms must have an egress window with 5 7 s f net clear opening 24 min height, 20" min. width 44" maximum from floor to window sill Windows must meet all 4 dimensions R310 1 9 Safety or tempered glass shall be used in windows that are (R308 4) • Adjacent to a door (24" arc of either edge of the door in a closed position) • That are closer than 18" to floor (AND individual pane is more than 9 s f top edge more than .36" a.f f and walking surface within 36" horizontally of thewindow in question) • Walls enclosing a tub or shower (AND within 60" of'the drain or within 60" of walking surface) R308 4 • Adjacent to stairways landings and ramps within 36" horizontally of a walking. surface (AND less than 60' a.f f of the walking surface) • Adjacent to stairways within 60" of the bottom tread of the stair in any direction (AND less than 60" a f f ) 10 Under -stair areas that are enclosed and accessible must be sheetrocked 1/2" GWB on walls and underside of the stairway R311 2 2 11 Stairways shall have 10" min tread and 7 3/4" max. rise R311 5 12. Provide 36' high guards (with 4 max. spacing on rails) at porches balconies and raised floor surfaces more than 30" above adjacent ground or floor R312 1 13. Smoke detectors required at all bedrooms hallway or room adjacent to bedrooms and at any ceilings that are more than 24" above adjacent ceiling All smoke detectors interconnected and hardwired with battery back-up R3131 14 Garage/house separation wall is 1/2" GWB door must be 20 min rated or 1 3/8" solid -core If living space above use 5/8' GWB Type 'X" at the ceiling AND 1/2" GWB at walls that support the floor above Ducts in garage must be 26 -gage sheet steel and have no openings in the garage R309 15. Exterior stairways must have a light located near the top landing of the stairway switched from inside (or have motion -activation device) R303 6 16. Minimum room areas must be provided (120 s f min in at least one room 70 s f min all other habitable rooms 7 foot min dimension in all habitable rooms) R304 1 17 Minimum ceiling heights must be. provided (7 foot min with some exceptions) R305 1 FOOTINGS, FOUNDATIONS, AND CRAWL SPACES 18. All footings including exterior isolated pad footings footing to finished grade R403 1 4 1 must have a 24" (min ) depth from the bottom of the 19 All footings shall be supported on undisturbed natural soils or -engineered fill Any placement of fill material that will support a structure will require a geotechnical investigation and report submitted to the City prior to placement of footings R401.2 & R403 1 20 Lots shall be graded to drain surface water away from foundations The grade shall fall 6" in the first TEN feet around the perimeter of the structure R401 3 21 Top surface of footings shall be level Bottom surface of footings shall not have a slope that exceeds (1) unit vertical in (10) units horizontal Any necessary stepping of the foundation must be approved during plan review or prior to installation of the foundation R403 1 5 T Building/Handouts/Residential Plan Review Guidelines (Rev 03-18-09) Page 2 of 8 22. Wood sill plates of all exterior walls interior bearing walls (slab -on -grade) and interior shear walls (slab -on - grade) must be anchored to foundation or slab with 1/ X 10" J -bolts with a 2' X 2' X 3/16" plate washer Anchor bolts to be placed a maximum of 12' and no closer than 3 '/2 from the ends of the sill plate Each piece of sill plate must have a minimum of (2) anchor bolts Anchor bolts shall be spaced no further than 6 feet apart (Special spacing and sizing condition's may apply at alternate braced wall panels) R403 1 6 23 6" clearance required from finish grade to foundation mudsill.plate R319 24 3 1/2" (min ) thickness for all concrete slabs -on -grade R506 1 25 Footing and foundation wall SIZES for two pour system. (Foundation walls NOT over 5 feet in height) • Footing supporting single story- 12' wide X 6" thick. • Foundation wall supporting single story- 6' thick • Footing supporting two stories- 15" wide X 7" thick. • Foundation wall supporting two stories- 8" thick. • Foundations that support. more than two stories require an engineered design 26 Footing and fnd REINFORCEMENT for two pour system (fnd. walls NOT over 5 feet in height) (Footings supporting single or two stories) • One continuous #4 horizontal rebar placed at center of footing with 3 (min ) clearance from dirt. (Foundation walls not over 5 feet in height) • One continuous #4 horizontal rebar placed within the top 12' of the wall • #4 vertical rebar placed at 48 inches o c max (wet set ok) with a 6 -inch 90 -degree hook. A minimum of (2) vertical bars to be placed at front garage wall returns 27 Monolithically poured foundation systems • Bottom of footing shall be 12' wide (min ) and extend to 24" below finished grade minimum • Footing shall have either one #5 continuous horizontal rebar placed at center and 8" above bottom of footing or (2) #4 continuous horizontal rebar placed at center and in the middle third of the footing measuring vertically • 3 1/2" minimum slab thickness • When a monolithic system is used to support heated spaces an R 10 insulation board must be installed on the outside of the foundation extending from bottom of footing to top of slab Exposed foam insulation above grade must be protected from damage and sun with approved materials The material used must extend a minimum of 12" below grade 28 Basement Walls (up to 9 feet) or Stem Walls (over 5 feet) or STEPPED FOUNDATIONS There are special restrictions for this type of foundation wall under the new code In plan view the length of this type of wall cannot exceed 35 feet. For stepped foundations this wall cannot exceed 7 feet high otherwise the floor joists must connect DIRECTLY to the wall (for bracing the foundation wall) WET -SETTING .IS NOT allowed for the alternating hooks into the footing There are special blocking requirements if any of these conditions cannot be met (note on the plans!) See R404 1 29 Under -floor pier pads supporting uniform load of wood framed floors shall be 18"x 18" x 8" (min ) Point loads from other than floor girders will require larger footings sized according to the concentrated load R403 1 1 30 Beams and/or girders in crawl space must meet span requirements for the loads imposed (from floor joists and from any point loads) R501 2 T Building/Handouts/Residential Plan Review Guidelines (Rev 03-18-09) Page 3 of 8 31 Access shall be provided to all under -floor spaces Access openings through the floor shall be a minimum of 18" x 24" Openings through a perimeter wall shall be a minimum of 16' x 24 R408 3 32. Under -floor spaces shall be ventilated by openings providing one (1) square foot of vent area per 150 square feet of crawl space. area One such ventilating opening shall be within 3 feet of each corner of the building R408 2 33. A ground cover .of 6 mil black polyethylene or approved equal shall be laid over the ground within crawl spaces The ground cover shall be overlapped 12" and extend to the foundation wall WSEC 502.1 6 7 -: 34 The under -floor grade shall be cleaned of all vegetation and organic material All* wood forms and construction debris shall be removed prior to final inspection R408 35. Thickened -slab footings must be 12" min total depth (top of conc. slab to bottom of footing = 12" total) (Revised from IRC) 36 Foundation cripple walls shall be framed of studs not less in size than the studding above Cripple walls with a height less than 14 inches shall be sheathed on one side with a wood structural sheathing or shall be of solid blocking Cripple walls count as an additional 'story" for lateral purposes ;R602 9 FLOOR FRAMING 37 18" (min ) clearance beneath all floor joists and 12" (min ) clearance beneath floor girders (beams) .in crawl spaces R308 38 Span of all joists (including 2nd level joists) must meet minimum live load of 40 psf (general living areas) or 30 psf (sleeping rooms) together with dead load of materials used R301 5 and Table R301 5 39 Span of beams for 2nd level or other supporting elements must meet minimum live and dead load requirements R3015 40 Wood posts in the crawl space shall have a connection to the concrete pier and a moisture barrier between the post and footing (or use pressure -treated posts) R319 & R407 41 Solid -sawn floor joists shall be blocked at all bearing points Engineered floor joists shall be installed per manufacturer's specifications R502 7 42. Cutting drilling and notching of floor joists shall not exceed the limitations in Figure R502 8 43. Cutting drilling and notching of engineered 1 -joists shall be in accordance with the manufacturer's specifications R502.8 2 44 All concentrated point loads originating from roof or floor load shall be transferred to bearing footings or foundation awalls Continuous support shall be provided by members that are equal in cross-sectional .area to the area of the load imposed and shall not be reduced in size at any point. 45. Wood members supported in concrete or masonry pockets shall have a Y2 inch air space provided at tops sides and ends of the member 46. All foundation plates sills and sleepers bearing on a concrete foundation or slab that is in direct contact with the ground shall be pressure treated All wood -framing members that rest on concrete foundations and are within 8" of exposed. ground shall be pressure treated R319 T Building/Handouts/Residential Plan Review Guidelines (Rev 03-18-09) Page 4 of 8 47 Sawn lumber floor joists shall have 1'/2" (min ) bearing and shall lap 3 min at intermediate girders Engineered I -joists shall have 1 3/4 (min ) bearing (or per manufacturer's specifications) 48 Floor joists that are parallel to bearing partitions shall be doubled Some heavier load cases will require girder beams or pony walls Bearing partitions perpendicular to floor joists shall not be offset from the supporting girder more than the depth of the joists unless the floor joists are of sufficient size to carry the load R502 4 49 Floor cantilever spans shall not exceed the depth of the nominal floor joists Floor cantilevers constructed in accordance with Table R502 3 3 (1) shall be permitted when supporting a light framed bearing wall and roof only R502 3 3 50 Block in between floor joists beneath all interior braced walls (for walls perpendicular to joists) or align floor joist with interior braced wall (see item #63-T) WALL FRAMING 51 Wall studs taller than 10 feet shall have a stud height analysis by a professional engineer or architect. Table R602.3 5 52. Non -load bearing stud heights shall be in accordance with Table R602 3 (5) 53 Studs shall be a minimum #3 grade standard grade or stud grade lumber R602 2 54 Where joists trusses or rafters are spaced more than 16' o c and the bearing studs below are spaced at 24" o c such members shall bear within 5' of the'studs below unless the top plates are double 2x6 or a third plate is added R602 3 3 55. Headers over windows and doors must meet minimum requirements for spans and imposed loads verify point loads over openings (from trusses or other conditions) and size headers accordingly Headers must be noted with size type and grade of lumber being used GENERAL NOTE STATING ALL HEADERS SHALL BE is acceptable 56 Interior bearing walls must have headers over openings and must be supported to a foundation 57 Top plate splices shall be offset a minimum of 24 inches R602 3 2 58. Fire -blocking required at dropped ceilings soffits coved -ceiling areas and every ten feet horizontally and vertically at framed walls R602 8 59 Port Angeles is in Seismic Zone D1 Wind zone of 100 MPH Category C (within 1500 ft from shore line is Category D) per the 2006 IRC When a house is considered 'IRREGULAR by any ONE the definitions below the code will NOT allow prescriptive bracing for Seismic Zone C and the entire house must have a lateral analysis and design by a licensed engineer (R301 2 2 2 2) Per that section of the code NO MIXING OF PRESCRIPTIVE AND ENGINEERED LATERAL SYSTEMS IS ALLOWED UNDER THIS NEW 2006, IRC. The following are items that constitute an IRREGULAR BUILDING per the 2006 IRC A. Exterior braced wall lines must be in one plane vertically from foundation to the uppermost story (basically the upper floor must match the lower floor footprint) The most common area where problems like this occur is in a garage with a second floor over it. To qualify for prescriptive bracing the second floor joists must extend to the exterior walls of the garage If this does NOT occur then your proposed house is IRREGULAR. If the joists do extend to the exterior walls of the garage then the setback of the second floor walls cannot be more than four (4) feet setback from the garage walls T Building/Handouts/Residential Plan Review Guidelines (Rev 03-18-09) Page 5 of 8 (see p 44 of the 2006 IRC) Rooms created by roof trusses are OK under this provision (such as bonus rooms over garages formed by the trusses/rafters) B The perimeter of all floor diaphragms and all roof diaphragms must be supported on WALLS below If you have beams holding up any part of the perimeter of a floor or a roof then your proposed house is IRREGULAR The most common place you will find this problem is at large covered porches and patios where the roof is supported only by post and beams Such covered porches and patios also make the building IRREGULAR Related to this are areas of discontinuous diaphragms, especially changes in plate line heights which also are considered as separate 'roofs and therefore make the building IRREGULAR C In any elevation of the exterior the braced walls from an upper level wall must NOT occur over a window or door In general this means that the windows of the upper story must align with the windows of the lower story There are some exceptions based on up-sizing the header in the window below (see 2006 IRC p 44 for details) D When an opening in a floor or roof. (such as a balcony -overlook area or a courtyard area) exceeds the lesser of 12 feet or 50% of the least dimension then your proposed house is IRREGULAR. E. When portions of a floor level are vertically offset (such as a sunken room) then your proposed house is IRREGULAR. This does not apply to a slab -on -grade floor F When braced wall lines do not occur in two perpendicular directions (such as portions of the house or garage at an angle to the .rest of the building) then your proposed house is IRREGULAR. G. If you have any portion of the above -grade walls that use masonry or concrete construction then your proposed house is IRREGULAR Stepped foundations that create a daylight basement situation are OK under this provision and do not make an irregular structure 60 THIS APPLIES TO ALL LATERAL BRACING (ITEMS 61 THRU 65) Add up all lengths of braced panels (4 foot braced panels 2'-8' alt. braced panels and 24 or 16' portal frames COUNT as 48' of length each portal frame counts as a total of 48' of bracing length—not 2 times 48") along the wall in question The total length of braced walls must be at least 16% of the entire wall length AND the panels must occur at least every 25 feet along the wall For 15' story of 2 -story house 30% of the entire wall length must be braced walls Check this for all braced wall lines including INTERIOR WALLS and including the front wall of a garage if it is not part of another braced wall line (i a the garage sticks out in front of the house more than 4 feet) See also #65 T below for areas where MORE than 35 feet between wall lines is needed 61 Garage lateral bracing systems with no 2nd floor above H Portal Frame for Garages (16" side panels @ 8 foot max. high walls 20' side panels @ 10 foot max. high walls) Alternate Braced Walls—single-story condition (2'-8' min width X 10 foot max. height) sheathed on one side (interior or exterior OK) with min 3/8' OSB or plywood and nailed with 8d common or galv box nails and blocked at all edges Two (2) anchor bolts in sill plate & two (2) hold-down devices @ furthest studs (1800 pound capacity hold-downs) J Alternate Braced Walls—first floor of two-story condition (2'-8' min width X 10 foot max height) sheathed on BOTH interior and exterior sides of wall with min 3/8' OSB or plywood and nailed with 8d common or galv box nails and blocked at all edges Two (2) anchor bolts in sill plate & two (2) hold- down devices @ furthest studs (3000 pound capacity hold-downs) There are some provisions for plate lines up to 12 feet high see Table R602 10 6 (basically a wider wall 3 -6' min length for 12 feet high) K. Front Garage Panels—no hold-downs required L. The exterior braced wall lines in a detached or attached garage cannot be more than 35 feet apart in either direction or interior braced walls must be provided 62. 1s` Floor Conditions Four (4) foot solid walls at all corners and at every 25 feet along any braced wall line OR use one of the methods below M Portal Frame for a House (slab -on -grade floors ONLY) 16 min width for one-story structures 24" min width for first floor of 2 -story T Building/Handouts/Residential Plan Review Guidelines (Rev 03-18-09) Page 6 of 8 N Alternate Braced Walls—single-story condition (2'-8" min width X 10 foot max. height) sheathed on one side (interior or exterior OK) with min 3/8' OSB or plywood and nailed with 8d common or gals box nails and blocked at all edges Two (2) anchor bolts in sill plate & two (2) 'hold-down devices @ furthest studs (1800 pound capacity hold-downs) O Alternate Braced. Walls—first floor of two-story condition (2'-8" min width X 10 foot max height) sheathed on BOTH interior and exterior sides of wall with min 3/8" OSB or plywood and nailed with 8d common or galv box nails and blocked at all edges Two (2) anchor bolts in sill plate & two (2) hold- down devices @ furthest studs (3000 pound capacity hold-downs) There are some provisions for.plate lines up to 12 feet high see Table R602 10 6 (basically a wider wall 3 -6' min length for 12 feet high) P "Simpson" Brand StrongWalls—this method is still available following all the .manufacturer's specifications for connections Q. Entire House Sheathed with OSB or Plywood—this method allows smaller side panels than 4 feet in accordance with Table R602 10 5 CHECK THE OPENING HEIGHTS ADJACENT TO THESE PANELS! 63. 1St Floor Conditions – Braced wall (any of the methods listed above) must start at no more than 12 5 feet away from the corner of the braced wall lines and then at every 25 feet (min ) along the wall line 64 2nd Floor Conditions – Braced walls (either of the methods listed below) must be within 12 5 feet of the corner of the wall line in question R. Standard four (4) foot panels on 2nd levels can start at no more than 12 5 feet away from the corner S Entire House Sheathed with OSB or Plywood—this method allows smaller side panels than 4 feet in accordance with Table R602 10 5 CHECK THE OPENING HEIGHTS ADJACENT TO THESE PANELS! 65 Exterior braced wall lines (or together with some interior wall lines) cannot be more than 35 feet apart. T Certain areas can be up to 50 feet apart between wall lines IF there is additional bracing along the exterior wall in question (50/35 = 1 43 more bracing than normally required or in other words 23% of the total wall in bracing for 1 -story wall 43% of the total wall in bracing for 1st story of a 2 -story house) R602 10 1 1 Exception 1 and 2 U Interior Braced Walls can be used when exterior walls are more than 25 feet apart. Interior Braced Walls are minimum 1/2" GWB both sides of wall for a minimum length of 48" use 5d nails or screws at 7' o c Sole plate of wall must be attached to thickened slab footing (see item #22 above) with 1/2' anchor bolt @ 6-0" o c or solid blocking (walls perpendicular to joists) or LINE UP JOIST with braced wall (walls parallel to joists) 66. The roof sheathing MUST nail into SOLID blocking and the block must connect to the double top plate either with clips or toe -nailed (for blocks that are top -beveled) with 8d @ 6' o c For ventilation use not more than two (2) 2' diameter holes BLOCKING MUST OCCUR AROUND ENTIRE PERIMETER OF ALL ROOFS Table R602 3 (1) This applies to all houses both engineered AND prescriptive bracing ROOF & ATTIC 67 Truss drawings must show reactions of all girder trusses point loads onto headers must have headers sized accordingly point loads over 5000 lbs onto double -top plates must be checked for bearing capacity Use Simpson brand TBE4 or TBE6 as needed to spread the load 68. Truss bottom chord live load must be minimum of 10PSF (see Table R301 5) Trusses must be sized for the roof coverings specified on the plans (concrete tile etc ) and roof structure must be able to hold up the roof (beams headers etc sized for roof loads) R802 10 2 69 Ice Shield is required for roofs up to 6 12 (6 12 and over DO NOT require ice shield) R905 2 7 1 T Building/Handouts/Residential Plan Review Guidelines (Rev 03-18-09) Page 7 of 8 70 Attic ventilation must be provided at 1/150'h of the attic area or 1/300th of the attic area if 50% of the venting can be 3 feet above the eave venting (roof jackvents are 49 sq. in./vent, ridge vents at 12 sq in./foot) R806 1 71 Attic mechanical equipment, -need light and switch nearopening and electric outlet. Access opening to such mechanical equipment must be no further than 20 feet from equipment with 22' wide (min ) walkway from access opening to the equipment. 72. Attic access required 22" X 30" min and shall be in hallway or other readily accessible location R807 1 MECHANICAL. 73 Appliances located in a garage or carport shall be protected from damage from vehicles M1307 3 1 74. Gas appliances located in a garage shall be raised 18" min above finish floor G2408.2.(305 3) 75. Ductwork that extends below grade (such as in the garage floor) shall be encased in 2" min concrete on all sides and bottom in addition to the R-10 insulation foam board 603 8 IMC 76 Dryer exhaust ducts shall not exceed 25 feet. in length The maximum length of the duct shall be reduced 2 5 feet for each 45 -degree bend and 5 feet for each 90 -degree bend Longer lengths in accordance with the manufacturer's listing will be allowed Screws shall not be used to connect any dryer duct materials M1501 3 77 Flex duct connections to sheet metal transition ducts shall have the inner sleeve taped with approved materials prior to securing the flex duct with a zip tie or similar fastener 304 IMC 78 Flex duct shall be supported every 4 feet and have no sag that exceeds '/z per foot. 79 All exhaust fan ducts shall be connected to the fan housing and termination fittings with a minimum of 3 sheet metal screws and be sealed with approved tape or mastic. 80 Exhaust fans required 50 cfm in bathrooms 100 cfm in kitchen 50 cfm min in laundry room and one fan sized for whole -house ventilation 302.2.2 WSVIAQ 81 Fuel -burning equipment shall not be installed in a closet, bathroom or a .room readily usable as a bedroom 82. Water heaters must be secured to structure with straps around tank at 1/3 points to resist lateral displacement. M1307 2 PLUMBING 83 Cleanouts shall be installed on all sinks and at the upper end of all building drains including any horizontal drain branches greater than 5 feet in length from the main line A cleanout shall also be installed on the exterior of the house within 24 inches of the foundation wall level with final grade and .shall have a threaded type cap installed 84 30" min width for toilet and 24 clear space in front of toilet (UPC) 85 Water heaters pressure relief and the required drain pan shall have a drain that is % ID copper or cpvc material NO coil material shall be allowed per code and no reduction in the pipe shall reduce the ID of the material less than % Pex type is a coil material and is not allowed for this application T Building/Handouts/Residential Plan Review Guidelines (Rev 03-18-09) Page 8 of 8 BUILDING PERMIT APPLICATION Print in ink CITY OF PORT ANGELES Attn Building Permit Technician 321 E. Fifth .St. Port Angeles, WA 98362 (360) 41:7-4815 fax (360) 417-4711 Applicant - L A 1/Z ay Property Owner .be ,.,v,s Property Owner's Address 1g,33 Contractors F Contractor's Address License # PROJECT ADDRESS Parcel Number Proiect Tvpe & Brief Description Check all that apply '� New Construction ❑ Addition ❑ Remodel ❑ Repair ❑ Demolition 1 / Ll (IIq W For City Use Only, Date Received 5-4!-09 ' Permit # Date Approved Phi ne, .41-97— 49G Phone qS' _ / Q0 _-2- Phone Phone E-mail p,��i� ,� olr _ � I.J %� \6L\� 6 k 5, S 6 V k� s 0. S' T, �. Lot Zoning ."Residential ❑ .Multi -family 0,0 NS Hls ❑ Commercial ❑ Industrial ❑ Re -roof ❑ House ❑ garage ❑ other ❑ tear off & re -roof ❑ lay over one layer ❑ Heat System ❑ Heat pump ❑ wood -burning stove ❑ gas fireplace ❑ pellet stove ❑other ❑ Other Floor, Areas Existinq (sg. ft.) Proposed (sq. ft.) Basement @ $ per sq ft. _ $ 1" Floor iS3 A�3O 560 2nd Floor 3rd Floor, �� p Garage S�2gj Carport 5,s1;L1 Covered Porch Deck Shed SYwA wiH bt de-mo'd of;� b��e � 601 A fh t'S home- Perown ev- ` p&rne p&4rni+- it oq-3$2 TOTAL VALUATION $ �g52, !, Total footprint of structures d2 i Q _. . _ sq ft. _ :Lot size 7000 sq ft. Lot coverage % Site Coverage = the amount of impervious surface on a parcel including structures paved driveways sidewalks patios and other impervious surfaces (see PAMC 17 94 135 for exemptions) Site coverage 4 5 • $ % end I oa sf-F+ of COnCY-g-60— +;L I& _ '3)i 10' s 1-4 — -7, &&0 Max height of proposed structures ft. Occupancy group # of bedrooms �'73 Will a lawn sprinkler system be installed? `� Occupant load # of full baths ;Z Willa fire sprinkler system be installed? Construction type # of half baths /have read and completed this application and know it to be true and correct. 1 am authorized to apply f mit'and understand that it is my responsibility to determine at permits are required, and to obtain permits prior to work' on rojects. Date-(, 09 Print Name L.,, �/ 4-.4 Signatur T Forms/Building Division/Bldg Permit.d / W C --,s Ir /0 DV 1-a S TT 6 �- 7' 91;), /�4 31 d f'\r -,'� ' t,r .�- spa Q`''om 0 5 `21� 61 �� oyx le 5 `�r� . RECEIVE -D' MAY 212009, CFIV �fNG DIVIS10N ANGELES 1 ��� TJ V's v k Q� PY Po R 1 J9,P) 6,fGtS lock T y > LL 45 CITY GOVERNMENT PRESCRIPTIVE APPROACH -SIMPLE FORM For the Washington State Energy Code (2006 Edition) Climate Zone 1 Site Information. Lot. n Address U- Ceiling, Vertical: : Over:fiead - Factor "; City- PIP fa i 4-W, 6-,L t s State UA! f Zip 9 9'3 6 -z- Contact. Contact. LY4 R;x � y LC Phone 7 — L/ 9 Phone 2 R21 FAX Building Department Use Only - Permit # © q — q V Notes Table 6-1 PRESCRIPTIVE REQUIREMENTS FOR GROUP R OCCUPANCY CLIMATE ZONE 1 (Unlimited Glazing Option Only) Glazing= I. = tor Glazing,UFacor Do I, , Qp ,!ori .: Area"'"/o" of ,Floor" U- Ceiling, Vertical: : Over:fiead - Factor "; Unlimited Ekterior Slab on " Floor Group R 3 Below IV and R-4 035 058 0.20 R 38 Occupancies "Grade Only R21 This Project complies with the following: Wall.... .Wall'' Wall Vaulted Above " Interior : Ekterior Slab on " Floor Ceiling Grade. Below �B6low Concrete , Gr"ade " "Grade R30 R21 R21 R10 R30 R10 The project is a single-family residence or duplex. The project is a wood frame OR all of the insulation is interior or exterior of the framing. All budding components meet the requirements listed above. The project will meet all other provisions of the WSEC and VIAQ The Project will take advantage of the following exceptions to the prescriptive option. ❑ 602.6 Exception 2. One unlabeled or untested exterior swinging door 24 sq ft. or less, may be installed per unit for ornamental, security or architectural purposes. Location of the door taking this exception ❑ 602.6 Exception 2. It a door is mostly glass, it should meet the requirement of the vertical glazing U factor listed above Location of the door(s) taking exception Type of Heat Source ,c- A--- PM N1-� d T Forms/Building Division/Prescrip e Approach -Simple Form Electrical -Ut^K Information F orm Public Works &Utilities Department (360) 417-470 City Electrical Inspector (360) 417-4735 Please complete and return toPublic Works & Utilities Department Permanent service. )Name . w� �� /S Name and add�ooof party — Shnet /;1* 3 3 14:- r+ _�. '7 - 7-nsoponoib|efnrpommanont responsible for permanent /City / State /ZIP P~P-_7- �]*^���_�J��. i41,4 q9 7�67— —~=`'`="''u' service billing? Daytime Phone a/,57 tqt),q, Home Phone, _—_ Contact Information (nother than above) Site contact: INam* �-'9/�/Q�� �/L�^Tb|e � | ' |DayUmePhono /] 7_- 4 96 4 Contractor, /Name Company - ompony-DayUmePhono Daytime Phone Electrician |Name. )?4837' [�x.4^v Company | |DaybmaPhone Excavator- Name Company - ompony-DayhmePhnne. Daytime Phone. Project Type:- 0Exiodng K«ew bmg!e'�m/ly residence El Multi -family residence #ofunbe______ 11 Commercial OGubdiviuion #of/ota______ DOverhead service DGenena|nemice [� ��Undecgroundsem /�ice ��Othnr ,Project Information ripdnnofwork: Str10Z61oetaddress/ lot number o��f- �J�� ��/ , /~/ex -7- Nearest cross. street: | Des�edoonneodondate | � L~�~� Electrical transformer serving property iu opepole n onthe ground Electrical. Load Total square footage ;L«n 4 __�sq ft. Main disconnect size 2-60 amps Voltage t9120/240 1ph Ell 20/208 3ph n277/480 3ph n120/240 3ph [_480 3VV3ph 0(]ther ^StandorUresidential loads (Lighting refrigerator dishwasher washer) Check all that apply S/VC(a hon) XRange/Oven 0Hot Tub C/cdheeDryer EJ Heating El Pumps (____Hp) ElNoLoad Change 19Water Heater 0Elevator (___Hp) El Other Please provide a copy of the following *Detailed plot plan (dwgor dxf format mandatory for subdivisions) *Electrical one -line drawing showing the service entrance panel and location *Connected load data. *Size andlocked mto�otf App)icanfaSignotune Data W1A|LORDELNERC[)K8PLETEOFORK8TO^�21E5THSTREET pORTANGELES WA 98382 FAX TO- 38O-417-4711 |nhorniuhonform xb WS WF CD � � /* 12 9i.2 o ,1114 49 107 1020 �N I (4/29/201.0) Linda-Pangrle --Re Residential Fuel Tank Abandonment Permits #09-824 &_09-478 _ _ Page 1 From, Ken Dubuc To: Linda Pangrle Date: 4/26/2010 12 31 PM Subject: Re Residential Fuel Tank Abandonment Permits #09-824 & 09-478 Linda Sorry for the delay, I've been out sick for the past week or so. 1710 W 4th abandoned on 8.28.09 114 W 10th abandoned on 5.21.09 Thanks, Ken >>> Linda Pangrle 4/20/10 4.38 PM >>> Hi Ken, When did you do your final approval inspection on these two permits? #09-824 at 1710 W 4th St. #09-478 at 114 W 10th St. Please let me know as soon as possible. Thanks, Linda It PORT ANGELES FIRE DEPARTMENT Abandonment of Residential Fuel Storage Tank 1,100 Gallons or Less Application for Permit 0 � - LA -1 1� Please call the Fire Marshal s Office at 417-4653 for assistance with the processing this permit. Site Address 1 i L4 t -v Name of Applica z > Address. C 2 7Y 4/dWp Site Owner - IDate: \,) — 9- Telephone: tAl A ITelephone: 7 r 9,0 Permits are issued at the City of Port Angeles Permits Counter located at City Hall, 321 E 5'h, Port Angeles, WA. Permit fee $15 00 paid to the City of Port Angeles Fire Department. Date paid. Date Issued. 5-2-6-09 Date Issued. Issued by - Additional Comments 4- 1 have read and understanthe re ul ills of 'till.) appl iro Applicant's Signature FP 25 A (Revised 12/9/04) Page 1 of 3 Section I - Required Information Applicant is required to furnish the following information on the space provided on the next page A site plan showing the number size, and location of the underground storage tank with reference to the existing home. 2 Specify the type of liquid which was stored in the tank. Section II - Requirements and Limitations Issuance of a permit is subject to. compliance with the listed requirements and approval by a field inspection of the Port Angeles Fire Department. Residential underground storage tanks may be abandon in place or removed. 1 There shall be no welding, cutting, or other sources of ignition in the area while abandoning operations are in progress. Welding or cutting on tanks require a separate permit from the Port Angeles Fire Department. 2 Removal of all flammable and combustible liquids from the tank and all connecting lines shall be pumped out. Please use a hand pump or other means to remove remaining flammable or combustible liquids as far as practical. 3 If the tank is removed and stored on site temporarily, the tank shall be placed in a secure location and blocked to prevent movement. The tank would be required to be inerted prior to being transported. The hole created by removing the tank shall be filled with a suitable material (earth, sand, etc ) 4 There are three options for the abandonment of residential fuel storage tanks. All three options require that the tank is first completely pumped out. __QptrQn #the tank and all associated fill and vent piping can be removed completely This ��-rs-generally the best method, however it is also the most expensive. Option #2 — The tank fill and vent pipes are removed, then the tank is filled completely with an inert mixture such as a sand slurry If Option #1 (complete removal) is not chosen, then this method is REQUIRED if the tank is within 5 feet of a property line, driveway, sidewalk, swimming pool, deck or building foundation. Option #3 — The tank fill and vent pipes are removed below grade and capped. The tank is left in place. If using this method, the applicant must read, understand and sign the following statement: "In using this method, I understand that the void created by the tank may cause a collapse of the adjacent ground if the tank rusts out over time." Applicant Signature Date FP 25 A (Revised 12/9/04) Page 2 of 3 �o7`lf STAEt-'F Site Diagram J To be completed by Fire Department Method of abandonment: ( ) Tank removed ( ) Tank filled with inert mixture ( ) Tank vent and fill lines capped below grade FP 25 A (Revised 12,19'04) Page 3 of 3 CITY OF PORT ANGELES DEPARTMENT OF COMMUNITY & ECONOMIC DEVELOPMENT BUILDING DIVISION 321 EAST 5TH STREET PORT ANGELES, WA 98362 Application Number Application pin number Property Address ASSESSOR PARCEL NUMBER Tenant nbr name Application type description Subdivision Name Property Use 09 00000382 Date 4/30/09 935428 114 W 10TH ST 06 30 00 0 3 2720 0000 DENNIS MICHAEL DOYLE DEMOLITION Property Zoning RS7 RESDNTL SINGLE FAMILY Application valuation 1y 0 Application desc one g h��P�" -5w DEMO HOUSE AND Tj1--' Ana a (FIRE DEPT DEMO D HOUSE) Owner Contractor DENNIS MICHAEL DOYLE OWNER 1233 E 3RD ST PORT ANGELES WA 98362 (360) 457 1902 Structure Information 000 000 DEMO HOUSE & TWO SHEDS Permit DEMOLITION one Shed Additional desc DEMO HOUSE & Permit pin number 145037 Permit Fee 50 00 Plan Check Fee 00 Issue Date 4/30/09 Valuation 0 Expiration Date 10/27/09 Qty Unit Charge Per Extension BASE FEE 50 00 Other Fees STATE SURCHARGE 4 50 Fee summary Charged Paid Credited Due Permit Fee Total 50 00 50 00 00 00 Plan Check Total 00 00 00 00 Other Fee Total 4 50 4 50 00 00 Grand Total 54 50 54 50 00 00 Separate Permits are required for electrical work, SEPA, Shoreline, ESA, utilities, private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned for a period of 180 days after the work has commenced, or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to.give authority to violate or cancel the provisions of any state or I cal 1 w regulating construction or the performance of construction. 07 0 Q e -U �, / le )a J' Date Print Name ytgnatur of C ntractor or Authorized Age Signature of Owner (if owner is builder) T:FonnsBuilding Division/Building Permit BUILDING PERMIT INSPECTION RECORD - PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS -- Building Inspections 417-4815 Electrical Inspections 417-4735 Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886 IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE. Inspection Type I Date I Accepted By Comments FOUNDATION Footings Stemwall Foundation Drainage / Downspouts Piers Post Holes (Pole Bldgs) PLUMBING (III Under Floor / Slab Rough -In Water Line (Meter to Bldg) Gas Line Back Flow/ Water (FINAL Date Accepted by AIR SEAL. Walls Ceiling FRAMING Joists / Girders / Under Floor Shear Wall / Hold Downs Walls / Roof / Ceiling Drywall (Interior Braced Panel Only) T -Bar INSULATION: Slab I i Wall / Floor/ Ceiling l MECHANICAL. Heat Pump / Furnace / FAU / Ducts Rough -In Gas Line Wood Stove / Pellet / Chimney Commercial Hood / Ducts (FINAL Date Accepted by MANUFACTURED HOMES Footing I Slab Blocking & Hold Downs Skirting IPLANNING DEPT Separate Permit#s SEPA. Parking / Lighting ESA. Landscaping I I SHORELINE. FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/ USE Inspection Type Date I Accepted By Electrical 417-4735 . Construction R W PW I Engineering 417-4831 Fire 417-4653 Planning 417-4750 Building 417-4815 T.Forms/Building Division/Building Permit C� OR7gq. BUILDING PERMIT APPLICATION Print In ink C� �r /'*�•"���- CITY OF PORT ANGELES For City Use Only Attn Building Permit Technician Date Received 321 E Fifth St. Port Angeles WA 98362 (360) 417-4815 fax 360) 417-4711 Permit # c�i-3�z � � �� l 7� Date Approved A G 7 7-YV �11 Applicant �; I�`i� I P Phone Property Ow��ner �� Phone Property Owner's Address 'POT- - PrF,l,s q B362 - Contractor D..),t n 15 _T),?,U_ f_Q_ r Q,_0 9 -*U n -t -o h-e_Rhone J Contractor's Address } I License # Expires E-mail PROJECT ADDRESS W / —s Parcel Number 0/ 000 :::2, 7 r-� Lot Jzy-Aja' Zoning /�S -% Proiect Tvpe & Brief Description. Residential ❑ Multi -family ❑ Commercial ❑ Industrial Check all that apply ❑ New Construction I ❑ Addition >v . t S S U 2 I Q eld id d t .lit 6-f, Ct 5 D -as fo S •-f­o M y lin 0-4-V%meq -e. ❑ Remodel i i S �0 n 1'1 Q. ❑ Repair �cY`ylr?�% Dov` aTV zti 'i Li(e/^ctse `demolition s � x -A c -A p %❑ a -roof ❑ House ❑ garage ❑ others ` ❑ tear off & Ie -roof ❑ lay o er ne layer ❑ Heat System ❑ Heat pump ❑ wood -burning stove ❑ gas fireplace ❑ pellet stove ❑ other ❑ Other Floor Areas Existinq (sg. ft.) Proposed (sq. ft. Basement 6 S heA w i (l( 6e, (am o @s J per sq ft. = $ 1St Floor-�j,,, may- Shed will bP r, S.eA -For S+D��u.aa�� 2"d Floor \M iwa h.Ornps ovt' J �2 (1S) �d �`-` 3Floor �Bro'dT —a Garage pann.o PP,rmid w=I1 be tsse +4A e- dem T Carport o'Fe .5-gncenall, sin Covered Porch �� Sue P.. Deck Shed Other TOTAL VALUATION $ Total footprint of structures sq ft. _ Lot size sq ft. = Lot coverage % Site Coverage = the amount of impervious surface on a parcel including structures paved driveways sidewalks patios and other impervious surfaces (see PAMC 17 94 135 for exemptions) Site coverage % Max height of proposed structures ft. Occupancy group # of bedrooms Will a lawn sprinkler system be installed? Occupant load # of full baths Will a fire sprinkler system be installed? Construction type # of half baths I haveread and completed this application and know it to be true and correct. l am authorizedN apply for this pe It and erstand that ittiis/ my responsibility to determine what permits �are rrequired, and to obtain permits prior to rking on projects Date '/Y�Z,?91/j 9 Print Name�,r�r`� s < t},� 1Ic�_ Signaturi �-r-- MA T ForQB il�f din Division/Bld Permit.doc 9 9