Loading...
HomeMy WebLinkAbout700 S Lincoln St - BuildingApplication Number Application pin number Property Address ASSESSOR PARCEL NUMBER Application type description Subdivision Name Property Use Property Zoning Application valuation Application desc 6 monitoring wells RUP #08 03 Owner CITY OF PORT ANGELES PO BOX 1150 PORT ANGELES Permit Additional desc Permit pin number Permit Fee Issue Date Expiration Date T•\Policies \1102.15R [1 /05] Qty Uhit Charge Per Fee summary Permit Fee Total Plan Check Total Grand Total WA 983620217 RIGHT OF WAY 6 MONITORING WELLS RUP #08 03 121210 70 00 Plan Check Fee 00 2/21/08 Valuation 0 8/19/08 Charged 70 00 00 70 00 08 00000201 148516 700 S LINCOLN ST R6 30 00 0 0 0000 0000 PUBLIC WORKS UTILITES UNKNOWN 0 BASE FEE CITY OF PORT ANGELES PUBLIC WORKS UTILITIES DIVISION 321 EAST 5TH STREET PORT ANGELES, WA. 98362 .Contractor OWNER Paid Credited'. 70 00 do 00 00 70 00 00 ZPiloP Date 2/21/08 Due .Extension 70 00 00 00 00 Separate Permits are required for electrical work, SEPA, Shoreline, ESA, utilities, private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned for a period of 180 days after the work as commenced, or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. Sig natur4 ofractor or Autl rized Agent [date Signature of Owner (if owner is builder) Date PW UTILITIES (Engineering Division) WATERLINE METER SEWER CONNECTION SANITARY STORM SITE DRAINAGE SITE EROSION CONTROL PARKING SIDEWALK CURB GUTTER DRIVEWAY APPROACH BACK -FLOW DEVICE T•\Policies \1102.15R 1/05] RESIDENTIAL CONSTRUCTION RW PW/ ENGINEERING 417 -4807 FIRE 417 -4653 I PLANNING DEPT 417 -4750 I BUILDING 417 -4815 PERMIT INSPECTION RECORD CALL 417 -4807 FOR UTILITY INSPECTIONS PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT IN A CONSPICUOUS LOCATION KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE INSPECTION TYPE DATE ACCEPTED COMMENTS YES I NO FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE DATE YES NO COMMERCIAL DATE I ACCEPTED YES NO I I I I I I I CONSTRUCTION RW PW ENGINEERING FIRE DEPT I PLANNING DEPT BUILDING Application Number Application pin number Property Address ASSESSOR PARCEL NUMBER Application type description Subdivision Name Property Use Property Zoning Application valuation Owner CITY OF PORT ANGELES PO BOX 1150 PORT ANGELES Fee summary Permit Fee Total Plan Check Total Grand Total Qty Unit Charge Per WA 983620217 Signat ru a o ontractorputhorized Agent T•\Policies \1102.15R [1/05] CITY OF PORT ANGELES PUBLIC WORKS UTILITIES DIVISION 321 EAST 5TH STREET PORT ANGELES, WA 98362 08 00000058 965728 700 S LINCOLN ST R6 30 00 0 0 0000 0000 PUBLIC WORKS UTILITES UNKNOWN 0 BASE FEE Contractor OWNER Permit RIGHT OF WAY Additional desc RUP# 07 57 8 MONITORING WELLS Permit pin number 119107 Permit Fee 70 00 Issue Date 1/16/08 Valuation Expiration Date 7/14/08 Plan Check Fee Special Notes and Comments Traffic control per approved plan advanced warning signs cones to be set flaggers on site Hours of operation subject to review Insurance Certificate to be on file Work to be done as described in 1/5/08 E mail and Airport loading access .ports Charged Paid Credited 70 00 70 00 00 00 00 00 70 00 70 00 00 ee Date Date 1/16/08 Due 00 00 00 0 0 0 Extension 70 00 Separate Permits are required for electrical work, SEPA, Shoreline ESA, utilities, private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days, if construction or work is suspended or abandoned for a period of 180 days after the work as commenced, or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of constructio Signature of Owner (if owner Is builder) Date PW UTILITIES (Engineering Division) WATERLINE METER SEWER CONNECTION SANITARY STORM SITE DRAINAGE SITE EROSION CONTROL PARKING SIDEWALK CURB GUTTER DRIVEWAY APPROACH BACK -FLOW DEVICE RESIDENTIAL CONSTRUCTION R W PW/ ENGINEERING 417 -4807 FIRE 417 -4653 PLANNING DEPT 417 -4750 I BUILDING 417 -4815 T\Policies 102.15R [1 /05] PERMIT INSPECTION RECORD CALL 417 -4807 FOR UTILITY INSPECTIONS. PLEASE PROVIDE A MINIMUM 24 HOUR NOTICE. IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED. POST PERMIT IN A CONSPICUOUS LOCATION KEEP PERMIT CARD AND APPROVED PLANS AT JOB SITE INSPECTION TYPE DATE ACCEPTED COMMENTS YES NO FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE DATE YES NO COMMERCIAL DATE ACCEPTED YES I NO CONSTRUCTION RW PW ENGINEERING I FIRE DEPT I PLANNING DEPT BUILDING Seal NOTARY PUBLIC for Washington, residing at My commission expires '(This :permit, if approved, may be terminated bythe City of Pon Angeles without cause and -at any time) (OFFICE USE ONL.YJ Date application received GD 07 Fee paid Date Certificate of Insurance per PAMC 11 12.140(B) received Agreement to Remove Encroachment signed and on and recorded on Application re is to deny or O RIGHT OF WAY USE PERMIT and recommendation by City Engiheer Date and with the following conditions R4.f J p n-rP0r fl+rLP, r y ')>n X1.1 t M P TIf) Application approved or denied by the Director of Pdbfic Works Approved copies to Applicant 0 Flre 0 Police 0 Street 0 Other 0 Addrass file 0 N :IFWKSIENGINEER1Urban Standards. Revised12006 VerstonlCh1iRDW Use PeriniLdoc f 0- _Receipt N/A /A Date ot-s8 1 f Z v1 c� r NAME OF APPLICANT cone, Ct1 V I c mttl \A DATE MAILING ADDRESS'S 5 e_ L j l✓i� -Q PHONE NUMBER Z G C A PI Cry J STREET ADDRESS OF.PROPOSED STREET:USE DESCRIPTION OF REQUEST .(include drawings required-forciarity): [If:street closure is requested please-state the name of the street and. limits of .closure, together with the. duration of closure,] rye P IS THE USE TEMPORARY OR. PERMANENT? rQru HOW LONG WILL THE OBSTRUCTION. BE IN PLACE? Z dti_t4 of WHAT ARE THE HOURS OF OPERATION? .R Ste. 3 HOW IT WILL BE LIGHTED? EXPLAIN THE. NECESSITY TO USE THE PUBLIC STREET SIDEWALK OR PLANTING STRIP ARE THERE ALTERNATE AREAS THAT. COULD BE USED? 1 Q./V. Er v C-ain A.:1,-k- do Pe;:, e_ HOLD. HARMLESS and INDEMNIFICATION AGREEMENT In compliance with:the Port Angeles Municipal Code, and in consideration ofthe issuance by the City of Port Angeles of a Right Of Way Use Permit•to:the undersigned allowing thepiacement.of the-above described street use or obstruction, the undersigned for himself and for tiie successors in-Interest, hereby agrees to Indemnify hold harmless, and defend.the City of Port Angeles against any claims lawsuits for-personal injury-or property damage arising out of or in any way connected with, the placement.ofthe use or on the' City street,. sidewalk, planting strip, or rigght f way DATED this '2, day of _T' .20 O 'f Applicant L t' \cc RUP# 07— 5 7 J _51 9 d KMW -4 Proposed Monitoring Well Location G it? ce" -Tjav' Supplemental Off- Site. Phase 11 ESA KA14 Proposed Rite Aid VKAONHENTAR tNC 7 10 722 S. Lincoln, Wash 121 o Eighth St. E" Port Angeles Off -Site Monitoring Well Locations rm u 12/20/2007 Trenia Funston RE. r/w use eit application w Pa e 1 gym From 'Cyrus Gorman <cgorman @kane- environmental corn> To 'Trenia Funston' Tfunston @cityofpa us> Date 12/20/2007 9:28 AM Subject: RE r/w use permit application Attachments City of Port Angeles.pdf Trenia Kane Environmental is requesting a Right of Way Use Permit to install eight monitoring wells The proposed monitoring well locations are shown on the attached figure The exact location of the monitoring wells will determined by field observations and the location of buried utilities There are four wells (KMW 5 through 8) that are proposed for installation on South Lincoln Street. There is one monitoring well (KMW -4) proposed for installation on 8th Street. Two monitoring wells (KMW 9 and 10) are proposed for installation on 7th Street. Lastly one monitoring will be advanced in the alley between 7th and 8th (KMW 11) as shown on the figure Kane Environmental has retained WorkZone Corporation of Puyallup Washington to complete a traffic control plan to provide flaggers for traffic management and to erect all necessary signs and placards Once they have completed the traffic control plan it will be forwarded to you Please let me the fee associated with the Permit and I'll have our accountant send a check in the mail Thank you Cyrus Gorman Staff Geologist Cell 206 550 6990 Fax: 206 675 0650 Original Message From Trenia Funston [mailto Tfunston @cityofpa.us] Sent: Wednesday December 19 2007 3 55 PM To cgorman @kane environmental corn Subject: r/w use permit application Here you go Trenia 1/5/2008 Trenia Funston RE. right of way useermit From 'Cyrus Gorman' <cgorman @kane environmental.com> To 'Trenia Funston Tfunston @cityofpa.us> Date 1/2/2008 7 09 AM Subject: RE. right of way use permit Attachments Port Angeles TCP.pdf Sample Monitoring Well Schematic.pdf Hi Trenia, I hope you had a nice holiday back to work so soon I have included with this email a copy of the TCP for the project. The answers to the questions from the engineer are below 1) The wells will be installed to determine the off -site impacts to groundwater if any from the historic gas station located at 722 S Lincoln St. 2 Unknown at this time This will depend on the client entering the Ecology VCP program If they do we will adhere to Ecology guidelines 3 Unknown at this time The wells will most likely be abandoned once monitoring activities if any are completed following Ecology guidelines 4) We will be installing 3/4 inch pre -pack monitoring wells with a direct push drilling rig 5) I have included a monitoring well schematic with this email Based on past drilling in the area the monitoring wells will be advanced to 15 -20 feet below ground surface dependent on the water table 6 The monitoring well locations will be based on the location of buried underground utilities and obstructions I will call the utility notification service and have them mark all utilities I will then inspect the markings prior to any work and make a determination of the well locations They are tentatively set to be advanced in the pavement. Please let me know if you have any further questions Thank you Cyrus Gorman Staff Geologist Cell 206 550 6990 Fax 206 675 0650 Original Message From Trenia Funston [mailto Tfunston @cityofpa us] Sent: Thursday December 27 2007 10 42 AM To cgorman @kane environmental corn Cc' Steve Sperr Subject. right of way use permit Cyrus RE The City Engineer has a few questions that need to be addressed before he will sign off on the application 1 What is the need for the wells? 2 Length of time proposed for monitoring? 3 Method of transferring wells to City if necessary or wanted? 4 Details of kind (type) of wells? 5 Detail of Monitoring port. 6 Exact locations in grass or pavement? Thanks Trenia Page 2 12/25./2007 22 33 2538419491 R ,9hr CR1Aae_ el0L t5 w g s; Pa 4d Work' R/tertd tou �N SPACE e X (f' Ems() Run 4$/$0 MPH 500'4- Ilrgan prtartot. 70445 eom �o•..- UrDm7 Streets Reektenfol& 25170 In 200' Business D1,4rt01e• Auag9Ra are 4a'7 4eWbWi* on orange 1.1141e0e o+heralee teatrtrtatad D AtevzAM 021ttet spew not Se Prr p q„— NV4 I 'wean I TM t1I1 50/50 I 40 1 T 51'4 p 99/45 1 35 1 90 W 2.0 23/30 1 20 I 40 F /A7cter (5ymbo0 w 0- 7A -0- o d O -AI O THE WORK ZONE CORP W 7 TW $r" PAGE 03/07 IZ O X S■ E o x L v st v c t -4 Z s 3 r v a ,0. st N ON V p 4 4 4 Y O L1/ p ru 0 tt ric Tfi 1 3 tt n 12/25/2007 22 33 2538419491 _§„t sFACIN X (F gT RNreliteode 49/00 MPH bcW Urban drearlole 75/40 fIn1 Wool Streets Streets Roelderrtfal6 25/30 HPN 260'6- Susumu mairlota 40e10t a are 4r X 4W bk on oronpe urecea ottrorvfae deetonatea I CNANWIIIRa: DV= SPACING war IV�N 1 1AWR, 1 t.I I7 30/60 1 4■ 1 e0 39/45 1 30 1 60 29130 f 20 I 40 ISI�'1 w S ‘2,,ir 1.41we closed .Tr ;411 cod w ;o -SR Pierre Le.# r(sy.rrbo) rinfre,6y,„ho 'tea woto -711 5c 5 4rraw 8onrc( +a C THE WORK ZONE CORP I I 1 Po,4 C.AAsrk 1411tA4 was f PAGE 04/07 �19 h7" Lm.ie closc.,re 5 5 L /NGa j,v 5 r' W S S 12/25/2007 22 33 2538419491 d i K m -10 Km, 1 F// ??c,- (y.nb40 LA.) 6 1 C-76 merle Lc.Fr 4.4 -,ZL R t yhi' (,Am. c.lasc.4 ,ij, caJ W2 5r Rc. csilt: i4l+eit w;t -I ur lRDOt 45/u0 om, 400%. txoan WIWI= 3B/40 MPH 350'+ Urban Streets RoeW.nttu1 6 26/30 Mill 2(57.- 9untrtens Utatrtats• hAfW}Ttm ars 4W X 4W tpa0it en mango waeae fathom/lad doatanated 1pt&tafE Z!M3 i MICE 5PA80 (1 7111 lttM U 'TAPEI t UMW 1 50/80 412 I BO 35/45 I 30 t 80 I 1-29-/AL-1--20 I dd I THE WORK ZONE CORP k) 7 r' SY PAGE 06/07 4,4 A) de, sr r n 5T i3 aw sd t 7 70 5 w s r'.1 10 15 20 25 5 MW -2.5.5 EE !n Z MW -2.3.5 30 Logged by Cyrus Gorman Driller ESN Northwest Drilling Method PowerProbe Sampling Method• Acetate Liner Casing Type: Not Applicable (NA) Annular Pack: NA Slot Size: NA Soils cic ifiec vis ally no al KANE RE 3831 Stone Way N, Seattle, WA 206-691-0476 wwv ane- environmental.com N u Qt 14 100 V 100 01 01 the Unified Soils alo in ati System cn O N Hammer Size. NA Date Drilled 09/22/07 Hole Diameter 2 inch Hole Depth 12 feet Well Diameter 3/4 inch Well Depth. 13 feet Screened Interval. 3 -13 ft Soil Description 0 -3 Asphalt Supplemental Phase II ESA Columbia Street Parking Lot Olympia Washington 3 –7.5 Brown fine– coarse sand with gravel and cobbles (loose moist) 7.5 –8 Grovel and coarse sand (loose saturated) (strong petroleum odor where satruated between 6 -8 feet) Depth to Water (First Encountered) 6 feet Depth to Water (Static) 5 4 feet Key: Concrete. Bentonite Silica sand Screen Boring MW -2 Page 1 of 1 Monitoring Well Schematic (1/14/2008) Trenia Funston Re ROW Use Permit for monitoring wells From Steve Sperr To: Gorman, Cyrus Date. 1/11/2008 12 37 PM Subject: Re ROW Use Permit for monitoring wells CC. Funston, Trenia Cyrus, I am OK with that. We will expedite processing the Permit, but cannot guarantee that the permit will be issued by Tuesday of next week. Trenia, Please proceed with processing the ROW Use Permit. Note that the Director is out of office next week. 'Cyrus Gorman' caormanakane- environmental.com> 1/11/2008 9:31 AM Hello, We have decided to go with heavy duty monitoring well cases. These are the same ones used at airports. They weight 40 pounds each, so I'm confident they'll meet or exceed your requirements. The subcontractor will be contacting Trenia to submit our documentation regarding bonding the City of Port Angeles for the project. Thank you Cyrus Gorman Staff Geologist Office. 206.691.0476 Ext 2 1 888.766 6802 Ext 2 Cell 206 550 6990 Fax: 206.675 0650 Page 1