Loading...
HomeMy WebLinkAbout1515 D St - Building PREPARED 12/01/10 8 30 28 INSPECTION TICKET PAGE 6 CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 12/01/10 ADDRESS 1515 D ST SUBDIV TENANT NBR CARLEEN S STOKES CONTRACTOR PHONE OWNER CARLEEN S STOKES PHONE (360) 477 4094 PARCEL 06 30 99 0 4 3010 0000 APPL NUMBER 09 00000212 DEMOLITION PERMIT DEMO 00 DEMOLITION REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS BL99 01 12/01/10 JLL BLDG FINAL November 30 20103 04 18 PM le FINAL I SCHEDULED THIS INSPECTION TO FINAL THIS PERMIT BUILDING FINAL DEMOLISHED A 460 SQ FT SHED & CARPORT COMMENTS AND NOTES PREPARED 6/19/09 8 59 30 INSPECTION TICKET PAGE 2 CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 6/19/09 ADDRESS 1515 D ST SUBDIV TENANT NBR CARLEEN S STOKES CONTRACTOR ANGELES CONSTRUCTION PHONE (360) 460 6508 OWNER CARLEEN S STOKES PHONE (360) 477 4094 PARCEL 06 30 99 0 4 3010 0000 APPL NUMBER 09 00000223 RES ADDITION PERMIT BPR 00 BUILDING PERMIT RESIDENTIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS BLFO O1 3/31/09 PB BLDG FOUNDATION TIME 09 00 3/31/09 DA March 30 2009 5 48 31 PM 1pangrle CARLEEN 460 6509 FOUNDATION MORNSAS POSSIBLE March 31 2009 3 27 31 PM pbarthol NO PERMIT ON SITE NO FOUNDATION WALL UNDER EXISTING WALL WHERE ADDITION IS ATTACHING SIDE YARD SETBACK NEEDS TO BE 7 FEET PB BLFO 02 4/03/09 PB BLDG FOUNDATION 4/06/09 AP April 3 2009 1 49 27 PM 1pangrle CARLEEN STOKES 460 6508 FOUNDATION April 6 2009 8 27 58 AM pbarthol BLIS O1 4/10/09 JLL BLDG INSULATION/SLAB TIME 09 00 4/10/09 AP April 9 2009 10 31 42 AM 1pangrle RICHARD 460 6508 SLAB INSULATION MORNING April 10 2009 4 29 19 PM permits BL9 01 4/24/09 PB BLDG SHEARWALL 4/27/09 AP April 24 2009 8 54 26 AM 1pangrle CARLENE 775 4933 SHEARWALL NAILING April 27 2009 8 40 25 AM pbarthol BLI 01 5/11/09 JLL BLDG INSULATION TIME O1 00 5/15/09 AP May 8 2009 1 07 29 PM 1pangrle CARLENE 775 4933 INSULATION AFTERNOON May 15 2009 3 39 11 PM jlierly BL99 01 6/19/09 ^.,ZLL BLDG FINAL TIME O1 00 �^ ' \An June 18 2009 8 22 34 AM 1pangrle �V � C IY�Yri��r CARLENE 775 4933 1`-� BLDG FINAL AFTERNOON PERMIT ME 00 MECHANICAL PERMIT REQUESTED INSP DESCRIPTION S �� TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ME99 01 6/19/09 J L MECHANICAL FINAL TIME 01 00 �J�J June 18 2009 8 23 46 AM 1pangrle CARLENE 775 4933 MECHANICAL FINAL ` Y AFTERNOON PERMIT PL 00 PLUMBING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS PREPARED 6/19/09 8 59 30 INSPECTION TICKET PAGE 3 CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 6/19/09 ADDRESS 1515 D ST SUBDIV TENANT NBR CARLEEN S STOKES CONTRACTOR ANGELES CONSTRUCTION PHONE (360) 460 6508 OWNER CARLEEN S STOKES PHONE (360) 477 4094 PARCEL 06 30 99 0 4 3010 0000 APPL NUMBER 09 00000223 RES ADDITION REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS PL2 01 4/10/09 JLL PLUMBING ROUGH IN TIME 09 00 4/10/09 AP April 9 2009 10 30 50 AM 1pangrle RICHARD 460 6508 ROUGH IN PLUMBING MORNING Apri1_10_,-2.0.0.9 4 2 51 19_PM_permits. PL2 02 4/27/09 JLL PLUMBING ROUGH IN TIME 01 00 4/28/09 AP April 27 2009 8 29 24 AM 1pangrle MIKE 477 9773 ROUGH IN PLUMBING AFTERNOON April 28 2009 8 30 04 AM jlierly PL99 01 6/19/09 LILL PLUMBING FINAL TIME 01 00 June 18 2009 8 24 09 AM 1pangrle CARLENE 775 4933 PLUMBING FINAL AFTERNOON COMMENTS AND NOTES PREPARED 5/11/09 8 28 15 INSPECTION TICKET PAGE 4 CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 5/11/09 ADDRESS 1515 D ST SUBDIV TENANT NBR CARLEEN S STOKES CONTRACTOR ANGELES CONSTRUCTION PHONE (360) 460 6508 OWNER CARLEEN S STOKES PHONE 1360) 477-4094 PARCEL 06 30 99 0 4 3010 0000 APPL NUMBER 09 00000223 RES ADDITION PERMIT BPR 00 BUILDING PERMIT RESIDENTIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS BLFO 01 3/31/09 PB BLDG FOUNDATION TIME 09 00 3/31/09 DA March 30 2009 5 48 31 PM 1pangrle CARLEEN 460 6509 FOUNDATION MORNING PLEASE INSPECT AS EARLY AS POSSIBLE March 31 2009 3 27 31 PM pbarthl _ NO PERMIT ON SITE NO FOUNDATION WALL UNDER EXISTING WALL WHERE ADDITION IS ATTACHING SIDE YARD SETBACK NEEDS TO BE 7 FEET PB BLFO 02 4/03/09 PB BLDG FOUNDATION 4/06/09 AP April 3 2009 1 49 27 PM 1pangrle CARLEEN STOKES 460 6508 FOUNDATION April 6 2009 8 27 58 AM pbarthol BLIS 01 4/10/09 JLL BLDG INSULATION/SLAB TIME 09 00 4/10/09 AP April 9 2009 10 31 42 AM 1pangrle RICHARD 460 6508 SLAB INSULATION MORNING April 10 2009 4 29 19 PM permits BL9 01 4/24/09 PB BLDG SHEARWALL 4/27/09 AP April 24 2009 8 54 26 AM 1pangrle CARLENE 775 4933 SHEARWALL NAILING April 27 2009 8 40 25 AM pbarthol BLI 01 5/11/09 JL BLDG INSULATION TIME 01 00 May 8 2009 1 07 29 PM 1pangrle CARLENE 775 4933 ry INSULATION AFTERNOON COMMENTS AND NOTES PREPARED 4/27/09 8 33 43 INSPECTION TICKET PAGE 10 CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 4/27/09 ADDRESS 1515 D ST SUBDIV TENANT NBR CARLEEN S STOKES CONTRACTOR ANGELES CONSTRUCTION PHONE (360) 460 6508 OWNER CARLEEN S STOKES PHONE (360) 477 4094 PARCEL 06 30 99 0 4 3010 0000 APPL NUMBER 09 00000223 RES ADDITION PERMIT PL 00 PLUMBING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS PL2 01 4/10/09 JLL PLUMBING ROUGH IN TIME 09 00 4/10/09 AP April 9 2009 10 30 50 AM 1pangrle RICHARD 460 6508 ROUGH IN PLUMBING MORNING 10-2089-4-29-19–PM -permits PL2 02 4/27/09 J L PLUMBING ROUGH IN TIME O1 00 April 27 2009 8 29 24 AM 1pangrle MIKE 477 9773 ROUGH IN PLUMBING AFTERNOON COMMENTS AND NOTES PREPARED 4/24/09 8 58 37 INSPECTION TICKET PAGE 2 CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 4/24/09 ADDRESS 1515 D ST SUBDIV TENANT NBR CARLEEN S STOKES CONTRACTOR ANGELES CONSTRUCTION PHONE (360) 460 6508 OWNER CARLEEN S STOKES PHONE (360) 477 4094 PARCEL 06 30 99 0 4 3010 0000 APPL NUMBER 09 00000223 RES ADDITION PERMIT BPR 00 BUILDING PERMIT RESIDENTIAI, REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS BLFO 01 3/31/09 PB BLDG FOUNDATION TIME 09 00 3/31/09 DA March 30 2009 5 48 31 PM 1pangrle CARLEEN 460 6509 FOUNDATION MORNING PLEASE INSPECT AS EARLY AS POSSIBLE March-31-, 009-3-.2-7-3 NO PERMIT ON SITE NO FOUNDATION WALL UNDER EXISTING WALL WHERE ADDITION IS ATTACHING SIDE YARD SETBACK NEEDS TO BE 7 FEET PB BLFO 02 4/03/09 PB BLDG FOUNDATION 4/06/09 AP April 3 2009 1 49 27 PM 1pangrle CARLEEN STOKES 460 6508 FOUNDATION April 6 2009 8 27 58 AM pbarthol BLIS 01 4/10/09 JLL BLDG INSULATION/SLAB TIME 09 00 4/10/09 AP April 9 2009 10 31 42 AM 1pangrle RICHARD 460 6508 SLAB INSULATION MORNING April 10 2009 4 29 19 PM permits BL9 01 4+24/09 JLr lI BLDG SHEARWALL April 24 2009 8 54 26 AM 1pangrle CARLENE 775 4933 SHEARWALL NAILING COMMENTS AND NOTES 1' ELECTRICAL PERMIT CITY OF PORT ANGELES �o 360-417-4735 � Application Number 09 00000357 Date 4/22/09 Application pin number 205585 Property Address 1515 D ST ASSESSOR PARCEL NUMBER 06 30 99 0 4 3010 0000 Application type descrip on ELECTRICAL ONLY Subdivision Name Property Use Property Zoning RS7 RESDNTL SINGLE FAMILY Application valuation 0 Application desc remodel 100 sub 8 circu}ts Bedroom baths _ 1 Owner Contractor STOKES CARLEEN S BOTERO & SON ELECTRICAL v 1039 W 16TH ST 940 TAMARACK WAY PORT ANGELES WA 983637431 PORT ANGELES WA 98362 Permit ELECTRICAL ALTER RESIDENTIAL Additional desc Permit pin number 144659 Permit Fee 109 75 Plan Check Fee 00 Issue Date 4/22/09 Valuation 0 Expiration Date 10/19/09 to Qty Unit Chargeer Extension L 8 00 2 0000 JH EL BRANCH CIRCUIT W/FEEDER 16 00 1 00 93 7500 E�H EL 0 200 SRV FEEDER 93 75 Fee summary Char�ed Paid Credited Due Permit Fee Total �09 75 109 75 00 00 Plan Check Total 00 00 00 00 Grand Total 109 75 109 75 00 00 INSPECTION TYPE DATE RESULTS INSPECTOR. DITCH Srcl ko o ROUGH IN h 6 0 FINAL tzz[o ------- COMMENTS Signature of owner or Electri al Contractor X Date RECEIVE ® O.-PaRr,1A,*r } City of Port Angeles Permit Application APR 2 2 2009 Building Division/Electrical Inspections 321 East Fifth Street—P.O.Box 1150 �►�,,'+•"- Port Angeles Washington,98362 Ph:(360)417.4735 Fax:(360)417.4711 LIGHT DEPT --mss Date: W 2 0 c 1 &2 Single Family Dwelling Multi-Family or Commercial* _Commercial Addition/Alteration I Remodel 1 Repair* b *Plan Review May Be Required, Plea a Complete Electrical Plan Review Information Sheet fW Job Address: t 1 5 t A r_ e (e L.01 1,93G3 v R Building Square Footage: Description of above 100 A8 jrWA D �?u b PC,n�� �ti OL c�� I �r G E e& o A.e t I bMk r Z eelt�� Owner Information I Contractor Information Name: 6, (I' th ej Poke. S Name, &iera ; ')a+n le.c.t�fi��• Mailing Address: l 15 1!5L S gtf e e-t Mailing Address: It 4o Tc.ma.r--t le. C.._ City t j State av Zip 10'S 6 Z City Q,,, P r j e,e S State. ""4 Zip, 13 G- Phone. Fax: Phone: 5 60—y Sz-1i0*Z Fax: qS-2- 147 License#I Exp. License#/Exp Go T F Q 5G !13 Z G-k Unit Charge Qty Total(Q!y Multiplied by Unit Charge) $ 93.75 _� $ 413 12 Service/Feeder 200 Amp. $113.75 $ Service/Feeder 201-400 Amp. $160.00 $ Service/Feeder 401-600 Amp. $205.00 $ Service/Feeder 601 1000 Amp. $291.25 $ Service/Feeder over 1000 Amp. $ 2.00 _ $_ Branch Circuit WI Service Feeder $ 57.50 $ Branch Circuit W/O Service Feeder $ 2.00 $ Each Additional Branch Circuit $ 72.50 $ Temp.Service/Feeder 200 Amp. $ 86.25 $ Temp.Service/Feeder 201-400 Amp, $116.25 $ Temp.Service/Feeder 401-600 Amp. $131.25 $ Temp.Service/Feeder 601 1000 Amp. $ 75.00 $ Portal td Portal Hourly $ 69.00 $ Sign/Outline Lighting $ 75.00 $ Signal Circuitl Limited Energy Commercial $ 50.00 $ Signal Circuit/Limited Energy 1 &2 Family Dwelling $ 50.00 $ Signal Circuit/Limited Energy Multi-Family Dwelling $ 93.75 $ Manufactured Home Connection $ 80.00 $ Renewable Electrical Energy 5KVA System or Less $ 86.25 $ First 1300 Square Ft. $ 27.50 $ Each Additional 500 Square Ft.or Portion of $ 57.50 $ Each Outbuilding or Detached Garage $ 86.25 $ Each Swimming Pool or Hot Tub $ 43.75 $ Thermostat $ Total Owner as defined by RCW 19.28.261 (1)Owner will occupy the structure for two years after this electrical permit is finalized.(2)Owner is required to hire an electrical contractor if above said propelq is for sale,rent or lease. After reading the above statement,I herby certify that I am the owner of the above named property or a licensed electrical contractor I am making the electrical installation or alteration in compliance with the electrical laws,N.E.C. RCW Chapter 19.28,WAC.Chapter 296-46B,The City of Port Angeles Municipal Code,and Utility Specifications. Signature of owner electrical contractor or electrical administrator ❑ Cash ❑ Check X Date: -1 X Credit Card# V i PREPARED 4/10/09 8 33 09 INSPECTION TICKET PAGE 3 CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 4/10/09 ADDRESS 1515 D ST SUBDIV TENANT NBR CARLEEN S STOKES CONTRACTOR ANGELES CONSTRUCTION PHONE (360) 460 6508 OWNER CARLEEN S STOKES PHONE (360) 477 4094 PARCEL 06 30 99 0 4 3010 0000 APPL NUMBER 09 00000223 RES ADDITION PERMIT BPR 00 BUILDING PERMIT RESIDENTIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS BLFO 01 3/31/09 PB BLDG FOUNDATION TIME 09 00 3/31/09 DA March 30 2009 5 48 32 PM 1pangrle CARLEEN 460 6509 FOUNDATION MORNING PLEASE INSPECT AS EARLY AS POSSIBLE ---Mal-ch-3-1—2-Ot 5-3--2-7- 3-1—PM—pba-rt-ho3 NO PERMIT ON SITE NO FOUNDATION WALL UNDER EXISTING WALL WHERE ADDITION IS ATTACHING SIDE YARD SETBACK NEEDS TO BE 7 FEET PB BLFO 02 4/03/09 PB BLDG FOUNDATION 4/06/09 AP April 3 2009 1 49 27 PM 1pangrle CARLEEN STOKES 460 6508 FOUNDATION April 6 2009 8 27 58 AM pbarthol BLIS 01 4/10/09 BLDG INSULATION/SLAB TIME 09 00 t[ April 9 2009 10 31 42 AM 1pangrle RICHARD 460 6 08 SLAB INSULATION MORNING PERMIT PL 00 PLUMBING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS PL2 01 4/10/09 L PLUMBING ROUGH IN TIME 09 00 April 9 2009 10 30 50 AM 1pangrle RICHARD 460 6508 ROUGH IN PLUMBING MORNING COMMENTS AND NOTES PREPARED 4/03/09 13 51 06 INSPECTION TICKET PAGE 1 CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 4/03/09 ADDRESS 1515 D ST SUBDIV TENANT NBR CARLEEN S STOKES CONTRACTOR ANGELES CONSTRUCTION PHONE (360) 460 6508 OWNER CARLEEN S STOKES PHONE (360) 477 4094 PARCEL 06 30 99 0 4 3010 0000 APPL NUMBER 09 00000223 RES ADDITION PERMIT BPR 00 BUILDING PERMIT RESIDENTIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS BLFO 01 3/31/09 PB BLDG FOUNDATION TIME 09 00 3/31/09 DA March 30 2009 5 48 31 PM 1pangrle CARLEEN 460 6509 FOUNDATION MORNING PLEASE INSPECT AS EARLY AS POSSIBLE March 3 , 2-0A-q-3- 2_7-3.LPM -pharLhol. NO PERMIT ON SITE NO FOUNDATION WALL UNDER EXISTING WALL WHERE ADDITION IS ATTACHING SIDE YARD SETBACK NEEDS TO BE 7 FEET PB BLFO 02 4/03/09 JLL BLDG FOUNDATION A April 3 2009 1 49 27 PM 1pangrle CARLEEN STOKES 460 6508 FOUNDATION COMMENTS �UVC- PREPARED 3/31/09 8 20 39 INSPECTION TICKET PAGE 7 CITY OF PORT ANGELES INSPECTOR JAMES LIERLY DATE 3/31/09 ADDRESS 1515 D ST SUBDIV TENANT NBR CARLEEN S STOKES CONTRACTOR ANGELES CONSTRUCTION PHONE (360) 460 6508 OWNER CARLEEN S STOKES PHONE (360) 477 4094 PARCEL 06 30 99 0 4 3010 0000 APPL NUMBER 09 00000223 RES ADDITION PERMIT BPR 00 BUILDING PERMIT RESIDENTIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS BLFO 01 3/31/09 JLL BLDG FOUNDATION TIME 09 00 March 30 2009 5 48 31 PM 1pangrle } CARLEEN 460 6509 FOUNDATION MORNING PLEASE INSPECT AS EARLY AS POSSIBLE COMMENTS AND NOTES I)V ��, V -«__ � r.... ,�,.. tip..- .«•t-.s-,-r...�...,. .-,- ..,- . - BUILDING DIVISION CITY OF PORT ANGELES Correction Notice Job :Located at Inspection of"your work revealed that the following is n t in accordance with the codes governing the work in this jurisdiction 1 These corrections must be made and are not to be- cpvered until reinspection is made. When corrections have been made, please call ' for Inspection Date Inspector for Building Division DO NOT REMOVE THIS TAG r CITY OF PORT ANGELES 1 DEPARTME14T OF COMMUNITY & ECONOMIC DEVELOPMENT BUILDING DIVISION � 321 EAST 5TH STREET PORT ANGELES WA 98362 Application Number 09 00000223 Date 3/20/09 Application pin number 424260 Property Address 1515 D ST ASSESSOR PARCEL NUMBER 06 30 99 0 4 3010 0000 Tenant nbr. name CARLEEN S STOKES Application type descrip i.on RES ADDITION Subdi-vision Name Property Use Property Zoning RS7 RESDNTL SINGLE FAMILY Application valuation 43350 Application desc 510 SQ FT ADDITION 2 BEDROOMS & 1 BATH Owner Contractor CARLEEN S STOKES ANGELES CONSTRUCTION 1515 D ST 2535 JAKES RD PORT ANGELES WA 98363 PORT ANGELES WA 98363 (360) 477 4094 (360) 460 6508 Structure 'Information 000 000 510 SF ADDITION 1 BATH & 2 BEDROOMS Permit BUI DING PERMIT RESIDENTIAL Additional desc 510 SF ADD 2 BDRMS/1BATH Permit pin number 142729 Permit Fee 609 65 Plan Check Fee 396 27 Issue Date 3/20/09 Valuation 43350 Expiration Date 9/16/09 Qty Unit Charge Per Extension BASE FEE 417 75 1.9 00 10 1000 THOU BL 25 001 50K (10 10 PER K) 191 90 Permit MEC ANICAL PERMIT Additional desc Permit pin number 142737 A Permit Fee 92 60 Plan Check Fee 00 \ Issue Date 3/20/09 Valuation 0 Expiration Date 9/16/09 �J Qty Unit Charge Per Extension BASE FEE 50 00 A 9V• 4 00 10 6500 E ME STOVE/FIREPLACE/MISC APP 42 60 Permit PL BIND PERMIT Additional desc Permit pin number 142752 Permit Fee 10/ 00 Plan Check Fee 00 Issue Date /20/09 Valuation 0 Expiration Date /16/09 Qty Unit Charge Per Extension BASE FEE 50 00 4 00 7 0000 EA PL-PLUMBING TRAP 28 00 Separate Permits are required for electrical work,SEPA, Shoreline,ESA,utilities, private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned for a period of 180 days after the work has commenced,or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application anI know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified hellrein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. 3" -o Ca e �a �,✓ Date Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is builder) T:FormsBuilding Division/Building Permit a BUILDING PERMIT INSPECTION RECORD y — PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS— Building Inspections 417-4815 Electrical Inspections 417-4735 Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886 IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE. Inspection Type Date Accepted By Comments FOUNDATION Footings Stemwall Foundation Drainage/Downspouts Piers Post Holes(Pole Bldgs) PLUMBING Under Floor/Slab Rough-In Water Line(Meter to Bldg) Gas Line Back Flow/Water FINAL Date Accepted by AIR SEAL. Walls Ceiling FRAMING Joists/Girders/Under Floor Shear Wall/Hold Downs Walls/Roof/Ceiling Drywall(Interior Braced Panel Only) T-Bar INSULATION Slab Wall/Floor/Ceiling MECHANICAL. Heat Pum /Furnace/FAU/Ducts Rough-in Gas Line Wood Stove/Pellet/Chimney Commercial Hood I Ducts FINAL Date Accepted b MANUFACTURED HOMES Footing/Slab Blocking&Hold Downs Skirting PLANNING DEPT Separate Permit#s SEPA. Parking/Lighting ESA. Landscaping SHORELINE. FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE Inspection Type Date Accepted By Electrical 417-4735 Construction R.W PW I Engineering 417-4831 Fire 417-4653 Planning 417-4750 Building 417-4815 T Forms/Building Division/Building Permit CITY OF PORT ANGELES DEPARTME14T OF COMMUNITY & ECONOMIC DEVELOPMENT BUILDING DIVISION r ` 321 EAST 5TH STREET PORT ANGELES WA 98362 Page 2 Application Number 09 0000022.3 Date 3/20/09 Application pin number 424260 Qty Unit Charge Pir Extension 1 00 7 0000 EA PL WATER LINE 7 00 1 00 15 0000 EA PL-SEWER LINE 15 00 1 00 7 0000 EA PL WATER HEATER 7 00 Special Notes and Commen s The Fire Department has reviewed the project application and has no comments March 18 2009 8 09 47 M sroberds Residential addition for total of 26% lot coverage/30% site coverage in the RS 7 �o land use issues Electrical. load calculations and electrical permits are required Although there isa 5 eewr essement along the east property line for the h me located at 10:39 W 16th St versify sewer. location prior to excavation Other Fees STATE SURCHARGE 4 50 Fee summary ChargEd Paid Credited Due Permit Fee Total 8 9 25 809 25 00 00 Plan Check Total. 6 27 396 27 00 00 Other. Fee Total 4 50 4 50 00 00 Grand Total- 1.2 0 02 1210 02 00 00 Separate Permits are required for electrical work, SEPA, Shoreline,ESA,utilities,private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned for a period of 180 days after the work has commenced,or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. Date Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is builder) T-FormsBuilding Division/Building Permit BUILDING PERMIT INSPECTION RECORD -- PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS— Building Inspections 417-4815 Electrical Inspections 417-4735 Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886 (^�` v IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED POST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE. Inspection Type Date Accepted By Comments FOUNDATION MonOP®ut- 4I3I03 -51J- Footings Stemwall Foundation Drainage/Downspouts Piers Post Holes(Pole Bldgs) PLUMBING Under Floor/Slab Rough-In L _ �- q-Z7-dq 'Kougk-�h.pjur4� -jL.L_ Water Line(Meter to Bld Gas Line p Back Flow/Water FINAL Date -0 (Accepted by ALL. AIR SEAL. Walls Ceiling FRAMING r^� Joists/Girders/Under Floor V ° Shear Wal Hold Downs _ Walls/Roof/Ceiling ' Drywall(Interior Braced Panel Only) T-Bar 1C' INSULATION 10-0LL-Slab t-- Slab Wall/Floor/Ceiling V ') MECHANICAL. �l Heat Pum /Furnace/FAU/Ducts Rough-In Gas Line Wood Stove/Pellet/Chimney Commercial Hood/Ducts FINAL Date Accepted b MANUFACTURED HOMES Footing/Slab -Blocking 8 Hold Downs Skirting PLANNING DEPT Separate Permit#s SEPA. Parkin /Lighting ESA. Landscaping SHORELINE. FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE (b Inspection Type Date Accepted By V) Electrical 417-4735 Construction R.W PW I Engineering 417-4831 Fire 417-4653 Planning 417-4750 1 A Building 417-4815 1 - r0q 1 m J..e 1 0 T.Forms/Building Division/Building Permit 0 o<�"r,q BUILDING PERMIT APPLICATION Print in ink ►�� CITY OF PORT ANGELES For City Use On[ 1Alttn: Building Permit Technician Date Received X321 E. Fifth St, Port Angeles,WA 98362 Permit# (360)4174815 fax(360)417-4711 ��I ��'(�� ate Approved 3 Applicant C ',elq Phone el-7-7 v 7,/ Property Owner Phone 4 -7 -/,c y Property Owner's Address 15- p Qv f- ANN E /,-S f 3�3 Contractor 41,y e/es C oivs><<acliv,a 2Ic1.444 1)4Ir 11C►.en! Phone G rpt~ Contractor's Address 1 �2_5 3 > \,,, -s o kis _v + ,a,v<; /mss N 2 0 3&s License# Cc c/ eiZ- * /iv 20 /1 Expires E-mail 1,le "INN ks' PROJECT ADDREI S Parcel Number Lot Zoning Proiect Type&Brief Description. "esidential ❑Multi-family ❑ Commercial ❑Industrial Check all that apply g(New Construction .i Add 4,o.,4 %6' x 33 13 IA SvL,4t� 5I JE cr i•,cWje ❑Addition / 5 'k7 1I3,4�t"eL;;n,— / (ri/e�- /SGlcv&r 3c2�/>Yife I tSnW Lcrl /u fw fSrnw/I 1,4-nr � ❑.Remodel lZOvn� /�)/X// G lA. (D°:k L- U /t5 V/J<r a.c, L� y S,ie c_Kc►�r'. w,�.c�•+:: ❑ Repair h a 11 Xq U KL'P Cxft cdou✓ y—{ c, X3 ❑ Demolition ,,( ❑ Re-roof ❑ House ❑garage ❑other o tear off& re-roof ❑lay over one layer ❑ Heat System ❑ Heat pump ❑wood-burning stove ❑gas fireplace ❑pellet stove ❑other ❑ Other Floor Areas Existing(so.ft.) Proposed(so.ft.) Basement @$ per sq.ft. _$ 1t Floor 2nd Floor 3`d Floor Garage Carport Covered Porch Deck Shed Other TOTAL VALUATION $ Total footprint of structures 1 1� S r- sq.ft. T Lot size 6 '7P sq.ft. = Lot coverage Q % Site Coverage=the amount of impervious surface on a parcel, including structures, paved driveways, sidewalks, patios, and other impervious surfaces. (see PAMC 17 94 135 for exemptions) Site coverage 30, ( % 181xt(0,sla61= 2V&SIM`+ ISIS= ;�)lo( -- 629as = 0a Max. height of proposed structures /a ft. Occupancy group #of bedrooms. `! L Will a lawn sprinkler systeim be installed? N t Occupant load #of full baths 2 Will a fire sprinkler system) be installed? NO Construction type I,joj= -C.�� #of half baths 0 /have read and completed this application and know it to be true and correct. tam authorized to apply for this permit and understand that it is my responsibility to i etermine what permits are required,and to obtain permits prior to working on projects. Date ?//6/07 �PrintlName R id-rc-A ginecx G 'Ii�itN Signature T:Forms/Building Division/Bldg Permit.doc a -t' h --_, c Lia At Z `1'L oCJ_Y -- i; Af At, ir,zj --------------- ------ — —-- ———— --- } � p elf .i ._. --- -- ----�� ---_-��:.__ _'_-_i�' o°�,� _ �cam•� �l,�' �; __ ° r e�^`J� ._ --------- w.� W � (hi Aie,. �II� ! �`vA]9` —W��4m � iY7k� ��Q• /�,'V��I Q 111) ---------- 140 -Z4 4f _4,ma- t v ILI e-—/ICil --jab)P41-P—aled �)—Af rg ueke 6/�CPOThe Cit of Port AngelesNit Y Building inspections Dept. Upon re��i wing the single-family residential plans submitted for permit, the following re some of the items that will need to be taLen in to consideration. 1 Foundatiop Footing The minimum size of a footing in Seismic zone D2 are as follows. (1 Store 12"MI/6" min.thick) (2 story 15"W/7"nun.thick) (3 story 23"W/8" nun. thick) (Load bearing value of soil 1,500 (psf).With 2#4 bars horizontal continuous 3" off the bottom of footing The minimum specified compressive strength of concrete in basement walls,foundLion walls, exterior walls and other vertical concrete work exposed to weather in moderate (weathering table 8402.2 of the IRC is 3000lbs with a min.of 5% air entrained, but not mord that 7% Foundations in seismic categories D2 that exceed 50'4"in either direction ares required to have a continuous footing per section R403.1.2-including support of an interior-braced wall line.Locating and marling the property boundary is required for a footing inspection. Tables in chapter 4 of the IRC.Will be applied for soils that are heavy in moisture(hydraulic) in nature or foundation wall over 5'-0"in height.Verify site conditions and unbalanced back fill at time of application.Foundations Drains are required as per section R 405.1 (see exception for soil classification) 2- Foundation walls.Vertical steel in foundation walls as of July 15' 2004 Vertical bar reqd to be'/"#4 bar with a hook and tied to the footing steel in place at 4'-0" O C.at footing inspection. Ohne#4 bar horizontal within the top 12"of the wall. '/"anchor bolt with a 3"a 3"a 1/"steel washer is required at 6'-0"OC for a 1 story and 4'-0"OC for a 2 story, along and within 1 "of each end the pressure treated sill plate. Crawl space ventilation is required at(11)s.f. of vent per (1501)s.f.of area per sec.R408.2.2003 IRC. 6 mill black poly is required in c awl space as a below grade moisture barrier per section R406.3.2 2003 IRC. Finish grade(shall be a 6"slope away from foundation within 10'-0" of the foundation wall measured horizontally as per sec.R406.3 2003 IRC. 3- Framing All connections from a pier to a post and beam are required to have positive connection p�r code.In addition any connectors/fasteners in contact with treaded wood are req'd to be hot dipped zinc/gals (See manufacture details.) All floor joist are required to be blocked with 2x material at the beam support. 7/16"OSB sheathing is required to be nailed to pressure t eated sill plate and bottom plate or sole plate of wall. (or other approved hold down's).Attic ventilation is required at(1')s1 of vent per(150')s.f. Of area with an allowable 50d/o of ventilation can be located in the upper portion of the ridge if applicable per 2003 IRC.Truss design and calculations are required upon submitting an application, lateral conne tions are required to end walls where truss/rafters are perpendicular to end walls.A truss/rafter tie shall be required to prevent uplift per code. 4- Braced wall Lines.In Seismic category D2 exterior and interior braced wall lines cannot exceed 25'-0" Wall bracing must start within 8'-0" of a transverse wall or a designed collector Stan dard wall bracing methods are required as per section R602.10.3 of the 2003 IRC.If the w�ll bracing methods cannot be met,then refer to "Alternate Braced wall panel" Section 602.1 .6 of the 2003 IRC.If any of the aforementioned methods cannot be met, engineering design will be required for the"SHEAR WALL" design. Section R602.10.9 for interior braced wall line support for 1 and 2 story buildings require a continuous footing supporting a raced wall line,interior and exterior not to exceed 501-0"intervals. 5- Egress. Ro ms used for sleeping are required to have one window with 5.7'S.F of openable space and a ill height of not more the 44" above finished floor for emergency escape per 2003 IRC. 6- Energy and Air Quality Insulation,Heating,Air conditioning,Lighting,Windows and Appliances to meet 2003 'WSEC &I'IAQ New single family structures are required to have a whole lion a exhaust fan with a 241ir timer per table 3-1,3-2,3-3 of the 2003 VIAQ Mechanical��resh air intake(FAI)is required to have a 24 hr timer or windows in all bedrooms and living,dining area may have intake ports for fresh air per 2003 VIAQ if zone heat is applicable. 7- Dry Wall. (Gypsum wall board)5/8"type"K"sheets rock is required in the accessible usable space under stairs and on ceiling of a garage only if a habitable area is located above the garage.The rating of the sheet rock&nail pattern must be visible to the inspector Nail pattern for all sheet rock 1/2" and 5/8" to be 8"on center and 12" OC if drywall.screws are used.Per table 702.3.5 of the 2003 IRC.Interior braced wall panels are to be inspected prior to tape,bed and texture.Moisture resistant wallboard is required around w/c.A cementuous backer board is required for tiled areas at tub and showers.Vapor barrier is required.A perm rated paint may be substituted for a poly vapor barrier on the warm in winter side. 8- Plumbing. Water heaters are required to have two approved seismic straps in the upper and lower 1/�rd of the tank per UPC.T&P valve to be 3/4"I.D and directed to the exterior and turned 90 degree downward not less that 6" 12"above finish grade.Water heater s are required to have a 26 ga.Pan of other approved drain pan with a'/"drain line from pan to exterior Impact protection for w/h and mechanical equip are required to resist 6,000lbs impact if lociited in the garage area.All DWV are req'd.to be tested under water pressure per 2003 UPC or air test(consult manufacture recommendations for air test)Min.test pressure in Residential LPG is 30 lbs. 9- Smoke detectors. shall be located in each sleeping room and in the hall leading to each sleeping area.One smoke detector is required at the top of each stairs,and at least one smoke detector is required on every floor level. Smoke detectors must be within 6"to 12"from the ceiling if mounted on wall.Smoke detector shall not be less than 36"from any air return.Power supply for smoke detectors shall be from the main house supply that is not switched and required to be battery back up.Smoke detectors to be inter-connected so that if one smoke detector alarm will start a chain reaction to all other smoke detectors as per code. 10- Maximum building height allowable is 30'-0"based on an average grade plain per 2003 IRC.Property pins shall be located and marked for a footing inspection to verify zoning set back requirements. 11 Safety glazed tempered glass required within 24"of any doorway edge, along with other requirement as per 2003 IRC. 12- All water,swer, gas,electrical,drywells,downspouts and footing drains are required to be inspected bei lore cover This letter is not intended to cover all items required by the City of Port Angeles,but is to serve as a guide to help�you understand frequently asked questions, "ALL WORK IS SUBJECT TO FIELD APPROVAL"4/05. Carleeen Stokes Home Addition edroom, bathroom and living room 1515 South D Street. Port Angeles, W hington 98363 360 477-4094 or 360 775-4933 carleenstokesC otmail.com Angeles Construction CCO1 ANGELC-0030A Richard D Gesellchen 2535 Jakes Road Port Angeles, WA 8363 Legal Washington tate (360)460-6508 Certified Journeyan Carpenter Washington State ince 1974 General Contracto Port Angeles, Was iington since 1970 '038 A Ire' 11-2 k nry ��",°s. ;�r:� �,� °� �Ste` , .5,r - °� a �' y �;� .i�y,,,u'"{# ,. m -' p�. ,ett,��;ra. � _ A ,N l� R Ff "M 1 N X 0� did .m' ,"3,,"�tl �'.YMu Fa �h V�� r'y' ' � 4 '�"�- - � F�+ r "fi 66""a� k �e'�';`- 1 ,. 1t't" "-t� I I'l"3 4�"' T IN., T V v AM' 4 .............. Table of Contents 1 Building permit application 2 Owner's Information FILE 3 Contractor's Information 4 Site Plan 5 Floor Plan 6 Foundation/Insulation Plan 7 Framing Io existing home & steps 8 Cross-sections 9 Cross-sections 10 Written Structural Design 11 .,Contractor's Plea 12 Lot Information r`="5 Ty Or,pO RrT ANGELES—ConsteM'On!'lPtic Cf The issuance of this permit:,ased upon these plans,sµecis`i- cat;ons and other data shall not prevent the building official from thereafter requiring the correction of errors in said pias, specifirations and other data, or from pre'°nting building operations being carried on thereunder when in violation of ail codes and ordinances e} this j�Z& BY �pprovai Date .J`�— 9 3ol U dra)i_ vat c. �0 r4- y(yw' wo baa -- _ m a0rl�r? H f 7h_ — _ e,C7 4v, iiv M �A+17�1a N.Y 7t7 — — �� r Ta kem Av - h ho*L" 5�rwwY j IVAR �a 'T ire-Pefe lv ' Me�nL gN ry t C ow)AckcF-b IV ' - N l0 lNSuL !, L C ,�.0 i top o� l�lvv�l� u>li1�5 - I�,LkrS, t cs P o 0,VC1Iu�►�Y L'�rU�ivy �oP o add ��-N wa.115 %L k .i v vL e-L 2Y �� f� s { . v (�t,(S � 7�r�`'J�Std "'�%��'•�� r✓r`J it r i cir-� ��,"`- �,�I'.' � t�� �, �� L� '^^-.-�._ ".--^a�.....,-� may```- �'.•'•'•,.� i �`� { U;,v i^�v�`i �2....��•- ...—e-•- � t �� i .�,'`. i ��aµ�' M1 w ." i.d f'� �y51 a1 I � ,,.i k, .�1rJu J^l sfP i th fir' i i CJ Image http://www.lds.org/ldsorg/v/index.j sp?vgnextoid=21bc9fbee98db010 ®2008 Intellectual Reserve,Inc.All rights reserved. f I rw 2 of 2 2/16/2009 6 42 PM V4. _ Pot / „ Y 38 iovs'KL ` !6 look V �� �►fit ��;� w _ {"_ Aft-, ON '51- -- D s -4,(i-c OA9 5, co/v -cl Fj C-7 Ouse w V- e s 47 Sty, v _—_ ._G d _,�'I�� �P�i��,"':� �'d� �' t� �� �a€cam``` � �" +d��3'n,$��Gs��l��.� !fir-1,� fY fir' 411dAl lv"A I { r i l _--- 6 al sal- { CC __--. -- --R`'i.-__/14.1 a� - - — �_— { _ — _ 7—Ar r CITY OF PORT ANGELES DEPARTM NT OF COMMUNITY & ECONOMIC DEVELOPMENT BUILDING DIVISION o� 321 EAST 5TH STREET PORT ANGELES WA 98362 Application Number 09 00000212 Date 3/06/09 Application pin number 206572 Property Address 1515 D ST ASSESSOR PARCEL NUMBER 06 30 99 0 4 3010 0000 Tenant nbr name CARLEEN S STOKES Application type description DEMOLITION Subdivision Name Property Use Property Zoning RS7 RESDNTL SINGLE FAMILY Application valuation 100 Application desc DEMO 460 SQ FT SHED & CARPORT Ij Owner I Contractor CARLEEN S STOKES OWNER 1515 D ST PORT ANGELES WA 98363 (360) 477 4094 Structure Information 0 0 000 DEMO SHED & CARPORT Permit DEMOLITION Additional desc DEAO 460 SF SHED/CARPORT Permit pin number 14 596 Permit Fee 50 00 Plan Check Fee 00 Issue Date 3/06/09 Valuation 0 Expiration Date 9/02/09 Qty Unit Charge er Extension BASE FEE 50 00 Other Fees �i STATE SURCHARGE 4 50 Fee summary Charged Paid Credited Due 11 \ Permit Fee Total 50 00 50 00 00 00 Plan Check Total 00 00 00 00 ` Other Fee Total 4 50 4 50 00 00 Grand Total 54 50 54 50 00 00 �/ \ Separate Permits are required for electrical work, SEPA, Shoreline,ESA,utilities,private and public improvements. This permit becomes null and void if work or construction authorized is not commenced within 180 days,if construction or work is suspended or abandoned for a period of 180 days after the work has commenced,or if required inspections have not been requested within 180 days from the last inspection. I hereby certify that I have read and examined this application ar�d know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified h�rem or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any state or local law regulating construction or the performance of construction. 3-4 -o9 Ca&deen I�S-61(es Date Print Name Signature of Contractor or Authorized Agent Signature of Owner(if owner is builder) T:FonnsBuilding Division/Building Permit BUILDING PERMIT INSPECTION RECORD -� 1 j — PLEASE PROVIDE A MINIMUM 24-HOUR NOTICE FOR INSPECTIONS-- N Building Inspections 417-4815 Electrical Inspections 417-4735 Public Works Utilities 417-4831 Backflow Prevention Inspections 417-4886 i IT IS UNLAWFUL TO COVER, INSULATE OR CONCEAL ANY WORK BEFORE INSPECTED AND ACCEPTED P,OST PERMIT INCONSPICUOUS LOCATION. KEEP PERMIT AND APPROVED PLANS AT JOB SITE. Inspection Type Date Accepted By Comments FOUNDATION Footings Stemwall Foundation Drainage/Downspouts Piers Post Holes;(Pole Bldgs) PLUMBING Under Floor/Slab Rough-In Water Line(Meter to Bldg) _ Gas Line Back Flow,/Water FINAL Date Accepted b AIR SEAL. Walls V ' Ceiling FRAMING Joists/Girders/Under Floor Shear Wall/Hold Downs Walls/Roof/Ceiling Drywall(Interior Braced Panel Only) T-Bar INSULATION. 1 Slab �J J Wall/Floor/Ceiling MECHANICAL. Heat Pum /Furnace/FAU/Ducts Rough-In Gas Line Wood Stove/Pellet/Chimney Commercial Hood/Ducts FINAL Date Accepted by MANUFACTURED HOMES Footing/Slab Blocking&Hold Downs Skirting PLANNING DEPT Separate Permit#s SEPA. Parkin /Lighting ESA. Landscaping SHORELINE. FINAL INSPECTIONS REQUIRED PRIOR TO OCCUPANCY/USE Inspection Type Date Accepted By Electrical 417-4735 Construction R W PW /Engineering 417-4831 Fire 417-4653 Planning 417-4750 Building 417-4815 S� T Forms/Building Division/Building Permit �! Yo<saRr,, BUILDING PERMIT APPLICATION Prirt in ink e.-�- CITY OF PORT ANGELES For City Use Only Atn Building Permit TechnicianDate Received 3- 6-0q 321 E. Fifth St. Port Angeles WA 98362 Permit# C) (360)417-4815 fax(360)417-4711 Date Approved 1. 1�_L/ Applicant or Agent La�,l�.ev� S-t-okeS _ Phone 3¢0 qQ 1 Property Owner Cour leevl 5+v kes Phone 360 q77-q0qq Property Owner's Address 1515- SO LcFk 0 Contractor/Engineer Phone Contractor/Engineer's Address License # Expires E-mail PROJECT ADDRES SIS , vu-{ k D Parcel Number Lot Zoning I Proiect Type&Brief Description. Residential ❑ Commercial ❑ Multi-family ❑Industrial Check all that apply ❑ New Construction She a S ❑Addition a eaci ❑ Remodel e le ,tfl(r0 WILI bje Yio r bl o ❑ Repair ❑ Re-roof (Demolition ❑ Heat System ❑ Heat pump ❑wood-burning stove ❑gas fireplace ❑ pellet stove ❑other ❑ Other I Floor Areas EXisting(sq. ft.) Proposed(sq, ft.) Basement @ $ per sq. ft. _$ 15` Floor 2nd Floor 3'd Floor Garage Carport Covered Porch Deck Shed Other TOTAL VALUATION $ 100 ad Total footprint of structures sq. ft. T Lot size sq ft. = Lot coverage % Max. height of proposed structures ft. Occupancy group #of bedrooms _ Will a lawn sprinkler system be installed? Occupant load _ _ #of full baths Will a fire sprinkler system be ihstalled? Construction type #of half baths _ I have read and completed thil application and know it to be true and correct. l am authorized to apply for this permit and understand that it is my responsibility to determine what permit are required, and-to obtain permits prior to working on projects Date 3-6 0 L Print Name(qYl Sib k es Signature_ 00-,,CJ� 40-41, 1 \� " =�'• ";1038. 'r� `:� \ I WO PkI Cal- Ov 57