Loading...
HomeMy WebLinkAbout911 W 14th St Technical - BuildingTECHNICAL Permit 0G -214 Address II W (4'A 5 Project description 6;ara_ae /�}Gr�ss�ru -es1 ��1 Date the the permit was finaled -Z,�— Number of technical pages 9 L i S e2 roe D.& st c CoLl cvtzL tons d 7-15 -06 4 -F1, re_viseti CaIcuto,44bios Med„ -12-47 Garage /ADU Structural Design for Emanuel Arslan Port Angeles, WA 98363 EXPIRES CA 0 4 SEASONS ENGINEERING, INC 619 SOUTH CHASE STREET PORT ANGELES, WA 98362 66 pa Ce 1 RECEI OCT 12 2007 CITY BUILDING DIV SION�S 4SEASONS ENGINEERING, INC Jim Lierly City of Port Angeles Building Official PO Box 1150 Port Angeles, WA 98362 Subject: Scope of Engineering for Enclosed is a complete revision for the structural design of the Garage /ADU for Emanuel Arslan At this time, portions of this structure that have been reviewed by the engineer include 1 Lateral Forces 2. Beams and Headers 3 Foundation Structural Design Emanuel Arslan 1118 W 7th Street Port Angeles, WA 98363 Please give me a call if you need any additional information Sincerely c Donna J Petersen P E. (360) 452 -3023 Fax (360) 452 -3047 619 S. Chase Street Port Angeles, WA 98362 October 11, 2007 Structural Design Emanuel Arslan 1118 W 7th Street Port Angeles, WA 98363 DESIGN CRITERIA ELEVATION LESS THAN 625 FT SNOW LOAD GROUND= 25 PSF SNOW ROOF 25 PSF LIVE LOAD 40 PSF (FLOOR) DEAD LOAD 10 PSF (FLOOR) DEAD LOAD =10 PSF (ROOF) DEAD LOAD 7 PSF (CEILING) WIND SPEED, VFM 80 MPH 3 SEC GUST, Vas 100 MPH EXPOSURE C SEISMIC ZONE D2 SOIL BEARING 1500 PSF REFERENCES (1) (3) (4) (5) (6) (7) DESIGN STRESSES DOUGLAS FIR/LARCH #2- 2 4 x Fb 900 PSI Fv= 95 PSI E= 1 6 (10) PSI DOUGLAS FIR/LARCH #1- 2 4 x Fb 1200 PSI F 95 PSI E= 1.8 (10) PSI HEM FIR #2 -2 &4 Fb 850 PSI F 75 PSI E= 1.3 (10) PSI GLU -LAM BEAMS 24F -V4 Fb= 2400 PSI (T) BOTTOM Fb= 1850 PSI (T) TOP F 165 PSI E= 1.8 (10) PSI INTERNATIONAL BUILDING CODE 2003 INTERNATIONAL RESIDENTIAL CODE 2003 TIMBER CONSTRUCTION MANUAL 3RD ED by AITC CONNECTORS FOR WOOD CONSTRUCTION by SIMPSON STRONG -TIE WESTERN WOODS USE BOOK by WESTERN WOOD PRODUCTS ASSOCIATION MAY 1996 NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION 1997 ROSBORO -APA WOODCAD, VERSION 1 1 by ROSBORO GLULAM RESOURCES 2000 RISA -2D RAPID INTERACTIVE STRUCTURAL ANALYSIS 2- DIMENSIONAL VERSION 5.5 2001 General Notes 1 Ground snow load 25 PSF roof snow load 25 PSF 2. Maximum soil bearing capacity 1500 PSF 3. Seismic Zone D2. 4. Wind, VFa 80 MPH, 3 second gust, Vas =100 MPH, Exposure 'C' 5. Notations on drawing relating to framing clips, joist hangers and other connecting devices refer to catalog numbers of connectors manufactured by the Simpson Strong -Tie Company San Leandro, CA. Equivalent devices by other manufacturers may be substituted, provided they have ICBO approval for equal load capacities. 6. Roof Trusses: Trusses shall be designed by the manufacturer and design calculations shall be submitted for approval prior to fabrication. Each wood truss shall carry a grading stamp. Top chord members shall be sized to accommodate roof snow load and appropriate snow drifts as noted in the IBC. No field modification of trusses will be allowed without the engineer's approval. Live load truss deflection shall be limited to L/360. Total load deflection will be limited to L/240. 7 Girder trusses shall be attached to wall framing with Simpson LGT2, minimum 2000 pounds uplift, or equal. 8. Contractor shall provide temporary bracing and shoring for the structure and structural components until all final connections have been completed in accordance with the plans. 9. Contractor shall be responsible for all the required safety precautions and methods, techniques, sequences or procedures required to perform his work. 10. Contractor initiated changes shall be submitted in writing to the structural engineer for approval prior to fabrication or construction. 11 Drawings indicate general and typical details of construction, where conditions are not specifically indicated but are of similar character to details shown, similar details of construction shall be used. General Concrete Notes (The Following apply unless shown on the plans) 1 All materials and workmanship shall conform to the requirements of the drawings, specifications, and the 2003 International Residential Code. 2. Concrete shall attain a 28 day strength of F'c= 2500 psi, 51/2 sacks of cement per cubic yard of concrete. 3. Reinforcing steel shall conform to ASTM A615 -76A, Grade 40, fy= 40,000 psi. 4. Reinforcing steel shall be detailed (including hooks and bends) in accordance with 30 bar diameters or 2' -0' minimum. Provide corner bars in all wall intersections. Lap corner bars 30 bar diameters or 2' -0' minimum. 5. Lap adjacent mats of welded wire mesh one full mesh at sides and ends. 6. No bars partially embedded in hardened concrete shall be field bent unless specifically so detailed or approved by the structural engineer 7 Concrete protection (cover) for reinforcing steel shall be as follows: Footings and other unformed surfaces: earth face 3' Formed surfaces exposed to earth, walls below ground, or weather #6 bars or larger 2' #5 bars or smaller 1 1/2' Walls Interior face 3/4' 8. Footings shall bear on solid unyielding natural earth free of organic material 4- Single story structures Two story structures Three story structures 12' below original grade 18' below original grade 24' below original grade 9. Slabs shall be placed upon compacted granular fill, 2' minimum thickness. Wood Framing Notes (The Following apply unless shown on the plans) 1 All wood framing details not shown otherwise shall be constructed equal to or better than the minimum standards of the 20031.R.C. 2. Minimum nailing requirements: Unless otherwise noted, minimum nailing shall be in accordance with Table R602.3(1) of the 2003 I.R.C. 3. All structural framing lumber such as 2x_ joists, and rafters to be Douglas Fir No. 2, SprucelPine /Fir No. 2, or Hem /Fir No. 2 kiln dried. 4. All 2x_ studs and blocking to be Douglas Fir construction, Spruce /Pine /Fir construction, or Hem /Fir construction grade. 5. All structural posts to be Douglas Fir No. 2. 6. All structural headers to be 4x Douglas Fir No. 2. 7 All Glu -lam beams to consist of Douglas Fir kiln dried 24F -V4 standard grade unless noted otherwise on plans. 8. All 2x framing lumber exposed to weather and /or moisture shall be Hem -Fir No.2, pressure treated in accordance with the American Wood Preservers Association standard for above ground use. 9. All 4x and 6x structural lumber exposed to weather and/or in ground contact shall be Hem -Fir No.2, pressure treated in accordance with the American Wood Preservers Association standard for ground contact use. 10. Framing connectors, nails, bolts, and other fasteners in contact with pressure treated wood shall have the following finishes: Wood Treatment I Finish I I CCA -C and DOT Sodium Borate (SBX) I Galvanized, 0.60 oz/fe ACQ -C, ACQ -D, CBA -A, CA -B, Other Borate I Post Hot -Dip Galvanized, ZMAX galvanized, (Non -DOT) I 1.85 oz/ft or SST300- Stainless Steel Steel Ammoniacal Copper Zinc Arsenate (ACZE) I SST300- Stainless Steel and other pressure treated woods. 11 When using Stainless Steel or hot -dip galvanized connectors, the connectors and fasteners should be made of the same material. Stainless Steel fasteners shall not be use in applications where contact with Galvanized and Post Hot -Dip Galvanized metals will occur 12. Individual members of built -up posts and beams shall each be attached with 16d spikes at 12' o.c. staggered. 13. All columns in framed walls to be well nailed into adjacent framing in order to resist lateral movement. 14. Provide solid blocking for wood columns and multiple studs through floors to supports below 15. Provide 4x10 headers, or double 2x10 headers over and double studs each side of all openings in stud bearing walls not detailed otherwise. 16. Provide 4x8 headers, or double 2x8 headers over and double studs each side of all openings in non structural stud walls not detailed otherwise. 17 At joist areas: Provide solid blocking at bearing points and at intermediate bearing locations. Provide double joists under all load bearing partitions. Provide double joists each side of openings unless detailed otherwise. 18. Provide double joist headers and double joists each side of all openings in floors and roofs unless detailed otherwise 19. Toenail joists to supports with 2 -16d nails, 2 -10d box nails for TJI joists. 20. Attach Joists to flush headers and beams with Simpson 'U' series metal joist hangers to suit the joist size. 21 All wood stud walls shall have lower wood plate attached to wood framing below with 16d nails at 12' o.c. staggered, unless otherwise noted in the shearwall schedule. 22. Plywood roof and floor sheathing unless otherwise noted on plan shall be laid up with face grain perpendicular to supports and nailed with 8d nails 6' o.c. to framed panel edges and over stud walls shown on the plans 12' o.c. to Intermediate supports. Provide approved plywood clips 16' o.c. at unblocked roof sheathing edges. Provide solid blocking at lines of support at floors. Toenail blocking to supports with 16d 12' o.c. unless otherwise noted in the shearwall schedule. 23. Provide continuous solid blocking at mid height of all stud walls over 10' in height unless wall is blocked per shear wall note. 24. Plywood wall sheathing for noted shear walls shall have solid blocking at all sheathing panel edges. See shear wall schedule for further notes. 6 Mork Sheeting Fastener spacing O all edges (Blocked) 7/16" OSB 8d 0 6" OC OR 15 GA 04" OC 7/16" OSB 8d O 4" OC OR 15 GAO 3" 00 plywood X 10d 0 3" OC 1/2" CDX 10d O 2" OC plywood 1/2" CDX plywood 1/2" GWB both sides 5/8" GWB both sides Notes: 2. 5. 6. 7 ARSLAN SHEARWALL NOTES 8d 0r OC OR 15 GA 0 2 -1/2" OC 5d COOLER 0 4' OC OR 5d GWB O4 OC 6d COOLER 0 4" OC OR 6d GWB O4 "OC SHEAR WALL SCHEDULE 1„ 7 Fromin B I ottom plate nailing I Anchor Bolts 9 doubled stud solicina Sheeted I (Sheeted one side both sides one side Intermediate framing nail spacing 8d 06'OC for stud framing 0 24" 8d 012' 00 for stud framin 016' 8d 0 6' OC for stud framing 024" 8d 012' OC for stud taming 0 16" 8d 0 6' OC for stud framing 0 24" 8d 012" OC for stud framing 0 16' 10d 0 6" OC for stud flaming 0 24" 10d 012 OC for stud framing 0 16" 10d 0 6" OC for stud flaming 024' 10d 012 OC for stud framing 0 16" 5d cooler 0 4' OC 5d GWB 04 "OC 6d cooler 0 4" 00 6d GWB 0 4 "0C ALL SHEAR PANELS SHALL BE BLOCKED. 1. ALL NAILS SHALL BE GALVANIZED BOX NAILS OR COMMON NAILS, 8d common 0.131'dla X 2- 1 /2'min. 10d common !0.148 "dia X 3 min. 8d box 0.113 "dia X 2 -1/2 "min. 10 box =0.128 dta X 3'rntn. 15 GA. staple =0.072 "dia X 1 -1/2' min. NAILS TO BE DRIVEN FLUSH WITH SHEATHING. DO NOT OVER DRIVE NAILS backing size 2x 240 PLF 2, 3, 6 2 -16d 0 2 -16d 0 1/2" X10' 5/8" X10" 480 PLF 12'OC 8'0C 0 48"0.C. O 30"0.C. 2x 350 PLF 2,3,5,6 2 -16d 2 -16d 0 5/8" X10' 5/8" X10' 700 PLF O 10 "OC 5 "OC 0 40" 0.0. 0 20" O.C. 3x or DBL.2x 3x or DBL.2x 3x or DBL.2x 2x 2x 4SEASONS Sheeted both sides 490 PLF 2, 3, 4, 5, 6 2 -16d 2 -16d 0 5/8 "X10" 5/8" X10" 980 PLF 0 7 "OC 3- 1/2 "OC 028" O.C. 014" 0.0. 2 -16d 2 -16d 0 5/8" X10" 5/8" X10" 200 PLF 2, 3, 4, 5, 6 0 6'OC 3 "0C 0 24" O.C. 0 12" O.C. 3 -16d 3 -16d 0 5/8" X10" 5/8" X10" 15 Z, 3, 5, 6 0 6'OC 3 "OC 018" O.C. 0 9" O.C. 2 -16d 0 5/8' X10" 12 "OC 0 48' 0.C. 2 -16d 0 5/8" X10" 10'OC 036" O.C. F ad cooler S 0.086 "dia X 5/5 nNG CRITERIA: 5d GWB 0.086 "dia X 1 -5/8 min. 6d cooler 0.092"dia X 1 -7/8' min. 6d GWB 0.092 "dla X 1 -7/8" min. 16d common 0.162 "dia X 3 -1/2' min. Maxiumum Notes allowble shear 300 PLF 375 PLF PROVIDE APA RATED SHEATHING PLYWOOD OR 058 APA RATED SIDING 303 OF INNER SEAL OSB RATED PANEL SIDING ON ALL EXTERIOR WALLS AND NAIL PER NOTE 1. 3, 6 3, 6 3 SPECIFIED SHEATHING AND SIDING PANEL EDGES SHALL BE BACKED WITH 2' OR 3' FRAMING (PER THE TABLE) INCLUDING FOUNDATION SILL PLATES, VERTICAL FRAMING, AND BLOCKING. PANELS MAY BE INSTALLED EITHER HORIZONTALLY OR VERTICALLY (SEE NOTE 4 FOR EXCEPTION). NAILS SHALL BE STAGGERED FOR .3' FRAMING. 4 7/16" OSB MAYBE SUBSTITUTED FOR 1/2' CDX PLYWOOD IF FRAMING IS SPACED AT 16' ON CENTER, OR PANELS ARE APPLIED WITH LONG DIMENSION ACROSS STUDS FOR FRAMING SPACED AT 24" (BLOCKED). WHERE PANELS ARE APPUED ON BOTH FACES OF A WALL AND NAIL SPACING IS LESS THAN 6 INCHES ON CENTER ON EITHER SIDE, PANEL JOINTS SHALL BE OFFSET TO FALL ON DIFFERENT FRAMING MEMBERS OR FRAMING SHALL BE 3 —INCH NOMINAL AND NAILS ON EACH SIDE SHALL BE STAGGERED. DATE. FEBRUARY 2006 SCALE. NONE 'DRAWN BY' DJP ENGINEERING, INC (360) 452 -3023 I CHECKED 619 S. Chase St. Port Angeles, WA 98362 I SHEET. 1 Garage /ADU, Emanuel *Arslan 111 :W :7th `St'reet Port-Angeles, WA198363 2003 IBC WIND ANALYSIS WIDTH LENGTH LEAST DIM )03 IBC SEISMIC ANALYSIS SIMPLIFIED BASE SHE/ BUILDING DESCRIPTION 26 C 301 261 S1 0.50 FIRST FLOOR Ss 1.25 SECOND FLOOR 9" SITE CLASS D THIRD FLOOR V2 ROOF HEIGHT 2 AVERAGE HEIGHT OF BUILDING 27 A 1 2.6 1 3 3 2A =11 6.0 II WIND EXPOSURE 1C; f s WIND SPEED 1100 MPH ROOF PITCH I P 7, `'31 121 14.041 P. XIwP830 P. AA .P..30 AREA A, p, AREA B, ps30 AREA C, ps30 AREA D ps30 AREA E, ps30 AREA F, ps30 AREA G, ps30 AREA H, ps30 E oh G oh COMPONENTS ZONE 1, 100sgft ZONE 2, 100 sqft ZONE 3, 100sgft EAVES Z3 AREA Iw= 1.37 1.37 1.37 1.37 1.37 1.37 1.37 1.37 1.37 1.37 1.37 1.37 1.37 1.37 1 1 1 1 1 1 1 1 1 60 1 1 1 1 LCI Ps30 LC1,P, LC 19.9 27.21 -6.6 -9.02 13.3 18.19 3.8 -5.20 19.1 -26.12 12.4 16.95 13.3 18.19 -9.5 12.99 -26.7 -36.51 -20.9 -28.58 :145 19.83 =21 -28.71 34 -45.39 -38;1 -52.09 19.9 -6.6 13.3 -3.8 19.1 12.4 13.3 9.5 -26.7 -20.9 -9.83 18.71 -35.39 -42.09 Fv Fa Sm1 Sms Sd1 Sds SEISMIC USE GROUP SEISMIC DESIGN CATEGORY LC2,P, RESPONSE MODIFICATION FACTOR 27.21 SEISMIC BASE SHEAR COEFFICIENT= -9.02 CONNECTION OF SMALL ELEMENTS 18.19 SHEAR COEFFICIENT= -5.20 HORIZONTAL DIAPHRAGMS -26.12 SHEAR COEFFICIENT= 16.95 BEARING AND SHEAR WALL 18.19 OUT OF PLANE WALL FORCES 12.99 SHEAR COEFFICIENT= 1.50 1.00 0.75 1.25 0.50 0.83 1 D 6 1/2 0.154 0.111 0.1667 0.3333 -36.51 MASONRY AND CONCRETE OUT OF PLANE -28.58 SHEAR COEFFICIENT= 1 0.6667 137.563ILONGEST TRUSS 2 FT OC 224.561 lEAVES ROOF DEAD LOAD 168.3771TRUSS UPLIFT HURRICANE CLIP H1 20 2 1;0 531 Garage/ADU Emanuel Ars Ian 1118W 7th Street Port Angeles, WA 98363 WALL TRIB THIRD AREA WALLA A B C D WALL B A B C D WALL C A B C D WALL D A B WALL SECOND WALL A WALL B WALL C WALL D LATERAL FORCE RESISTING SYSTEM WIND LOADS (AREA)(PRESSURE)ILENGTH SHEAR WIDTH I HEIGHT PS I FORCE I LENGTH FT I FT PSF I LBS I FT 8.0 I 43 27.21 I -9.02 I 18.19 I -5.20 27.21 -9.02 18.19 5.20 27.21 -9.02 18.19 -5.20 1086.0 27.21 -9.02 18.19 -5.20 1086.0 TRIB AREA A B C D A B C D A B C D A B C D 4“.K„ 1 1 80 I *3:4 3.3, 70 I 35 L. 80 I 33 90 P I 0. 1 I 1327.0 30 1327.0 ,0 26 5 LATERAL FORCE RESISTING SYSTEM WIND LOADS (AREA)(PRESSURE)/LENGTH SHEAR WIDTH I HEIGHT PS I FORCE LENGTH FT I FT PSF LBS FT 7,6:0:1 136 27.21 I r.7 I 9.02 I O1136 18.19 I -5.20 I 4197.0 30 80 :A: .138 :T 27.21 I -9.02 50 136 15.10 -5.20 4197.0 1,77;.$ 2 I 120 80 33 -9.02 70 I 120 18.19 90 33 -5.20 3747 1 ;26 27.21 8.'0 9.02 it) 18.19 5 .20 3747 1 1 :Z SEISMIC LOADS SHEAR TRIB I WIDTH I DL SHEAR PLF AREA I FT I PSF COEFF ROOF I :1'7.011 it FLOOR I WALL 1 I 17 FLOOR 1 WALL ROOF ftti r 0 154 44.2 ETC. 44.2 ETC. t 0.154 ROOF 196 I 17 FLOOR WALL 70 I 41.8 ETC. 0.154 ROOF FLOOR WALL 7.0' 1: 41.8 ETC. 1„ 4 0.154 SEISMIC LOADS SHEAR TRIB PLF AREA ROOF FLOOR WALL 139.9 ETC. ROOF FLOOR WALL 139.9 ETC. ROOF FLOOR WALL 144 1 ETC. ROOF FLOOR WALL 144 1 ETC. WIDTH I DL I SHEAR FT I PSF COEFF eAtd1. 140 I 17 I 0.154 170 17' 120 17 0.154 14:657,1 „17,1 150J 17 0.154 196 I 17 0,1 :611 70 8 0.154 SHEAR I SHEAR LBS IPLF 1592.3 1556.8 1556.8 SHEAR LBS 2986.2 2829.2 1592.3 I 53.1 53.1 59.9 59.9 SHEAR PLF 99.5 94.3 2832.8 I 109.0 2832.8 I 109 0 Cl WALL FIRST WALL A WALL B WALL C WALL D TRIB AREA A B C D A B C D A B C D A B C D LATERAL FORCE RESISTING SYSTEM WIND LOADS (AREA)(PRESSURE)/LENGTH SHEAR I WIDTH I HEIGHT PS FORCE LENGTH I FT I FT PSF LBS FT '22:6 27.21 -9.02 1. 2 50 I 226 18.19 -5.20 69744 27.21 -9.02 50 226 18.19 5.20 6974 4 8.8E.1.4 21O 27.21 8G' '33 4• -9.02 18.19 90 33 -5.20 6851.8 27.21 -9.02 I :270 LV3 18.19 3 3 5.20 6851.8 SHEAR TRIB PLF AREA ROOF FLOOR WALL 232.5 ETC. ROOF FLOOR WALL 232.5 ETC. ROOF FLOOR WALL 285.5 ROOF FLOOR WALL 285.5 IIETC. WIDTH I DL FT I PSF 150 I 17 8.!,"„: 1170 I17 15P; I: 196 17 350 17 1 A*0. 8, SEISMIC LOADS SHEAR COEFF 0.154 0.154 SHEAR LBS 4380.0 4693.8 0.154 4106.6 0.154 4106.6 SHEAR PLF 146.0 156.5 171 1 171 1 Garage/ADU Emanuel Ars lan 1118 W. 7th Street Port Angeles, WA 98363 PERFORATED SHEAR WALL DESIGN I I IWALL DL IROOF DLI FLOOR DL I 1 I I I I I 1 I 1 I I I 1:...., `171; -w... ..15' Level I I I I I I 1 I I I I I I I THIRD I I WIND I SEISMIC I OVERALL I MINIMUM PIER I I I I RESISTANCE 1 DESIGN I SHEAR I TRIB I TRIB 1 I WALL I SHEAR I SHEAR I HEIGHT' WIDTH I HEIGHT' WIDTH I MAX OPENING! OF WALL I OF FULL I ADJUSTMENT I SHEAR I WALL I ROOF I FLOOR I UPLIFT WALL A 'PANEL' 44 .2 I 53.1 30 I I HEIGHT (FT.) I HEIGHT I HEIGHT SHTHG. FACTOR PLF TYPE I FT I FT LBS. I A I 41.7 I 50.1 7 I.. „26! ''.7, I'.<'"- I I 43 I„:_. .'I 0.93 I 78.3 I 1 I 15' I 1 0.0 B 60.5 I 72.6 7 I _a. ..f .s,...' I 0 .3:00 1.00 I 72.6 1 15 f :11. 160.0 WALL B I I 44.2 I 53.1 I 301 I I I I I I I I I I WALL C I A 1 41.8 I 59.9 7 1 .......A.1 Ii la.. 43 h cI 0.91 97 4 1 I_ 15_ _I 0.0 I I I I I I I I A 413 1 59.9 7 I .rI .r:..... I.s„.F:. I c:. ,I I ,y_.._. 0.93 916 1 I 3 I.. J 0.0 WALL D I I 41.8 1 59.9 I 261 1 I I I I I I I I I 0.83 I 79.4 I 1 L at:' L_ 0.0 1.00 I 66.2 1 I" t. 308.9 I I I SECOND I WIND I SEISMIC OVERALL I MINIMUM PIER I I RESISTANCE I DESIGN I SHEAR 1 TRIB I TRIB I I WALL! SHEAR I SHEAR I HEIGHT' VVIDTH I HEIGHT! WIDTH I MAX OPENING! OF WALL OF FULL ADJUSTMENT 1 SHEAR I WALL I ROOF I FLOOR 1 UPLIFT WALL A 'PANEL! 139.9 99.5 PLF PLF FT. FT. 30 I FT. I FT. 1 HEIGHT (FT.) I HEIGHT HEIGHT SHTHG.I FACTOR PLF TYPE I FT. I FT I LBS. 0.80 I 221.3 1 1 U. 16C.:1 .`5'. I 0.0 130 I 1763 1 I 15 cId_ x 5 a 1531.0 WALL 13 I 139.9 94.3 301 I I I I l73' 0.71 193.9 1 I 1 5 i ,I. 2 A5 I 0.0 I I I 1.61x 0.90 215.0 1 884.9 s, h WALL D I 1 144.1 I 109.0 I 261 I I I I I I A I 187 4 141.6 8 .;2 0 I_ I':. 0 I 0 I 1 I 1.00 I 141.6 1 Level I I I I I FIRST I WIND I SEISMIC OVERALL I MINIMUM PIER I I I RESISTANCE WALLI SHEAR 1 SHEAR HEIGHT' WIDTH I HEIGHTI WIDTH MAX OPENING! WALL 1 FULL I ADJUSTMENT PANEL! PLF I PLF FT. FT. I FT I FT HEIGHT (FT.) HEIGHT HEIGHT SHTHG.I FACTOR WALL A I 232.5 146.0 301 I I A I 861.0 5401 8 2 :71, ."aasii:1 0'.,.; :I 0 I,',.: .1.00..... :I 1.00 615.0 B I 861.0 540.7 8 i;:71° 771 0 ':I 0 I 1.00' I 1.00 615.0 C I 8613 540.7 8 :2.71: 'IL 0 1.- ...:..1 .00_ I 1.00 6153 WALL B 1 232.5 156.5 30 I I A I 2323 1563 8 I 17 84 WALL C I I 285.5 171.1 I 241 I I A I 285.5 171 1 8 I ..s 24 1 ...__...:I: WALL D I I 285.5 171 1 I 241 I I A I 342.6 205.3 8 I:.._,.. PSI I DESIGN I SHEAR SHEAR! WALL PLF I TYPE 1(2 SIDES) 3 1(2 SIDES) 3 I (2 SIDES) 3 TRIB ROOF FT Ilk 15 TRIB FLOOR FT 12; .'I 862.8 UPLIFT LBS. 6503.5 6503.5 6503.5 0.80 0.76 272.4 I 2 15 I 12.5 1 0.0 3.5 44 0.79. 0.94 2719 2 3 i ......2 0 0 I 1.00 I 130 244.7 2 3 1897.7 2014.7 ""R" x i t� t- t-- "F\ �z cE =.i f ARSLAN 3RD FLOOR BEAM 1 2004.2 Allowable Stress Design NOTE. 1. THIS COMPONENT IS DESIGNED TO SUPPORT ONLY THE VERTICAL LOADS SHOWN VERIFICATION OF LOADING, DEFLECTION LIMITATIONS, FRAMING METHODS, WIND AND SEISMIC BRACING, AND OTHER LATERAL BRACING THAT IS ALWAYS REQUIRED IS THE RESPONSIBILITY OF THE PROJECT ENGINEER OR ARCHITECT. 2. PROVIDE RESTRAINT AT SUPPORTS TO ENSURE LATERAL STABILITY 3. DO NOT CUT NOTCH OR DRILL GANG -LAM. 4. SHIM ALL BEARINGS FOR FULL CONTACT 5. VERIFY DIMENSIONS BEFORE CUTTING GANG -LAM TO SIZE. 8. THIS GANG -LAM IS TO BE USED AS A FLOOR BEAM ONLY 7 PROVIDE COMPRESSION EDGE BRACING AT EACH END OF COMPONENT SUPPORT REACTIONS (LBS) CASE B E A R I N G N U M B E R 1 2 1 7153 7153 2 2157 2157 I MIN BEARING SIZES (IN -SX) 3 0 3- 0 MAXIMUM DEFLECTIONS CALCULATED ALLOWABLE LIVE LOAD 0 21 0 28 °DEAD LOAD 0 14 TOTAL LOAD 0 31 0 56 Handling 8 Erection Temporary and permanent bracing for hosing component plumb and for resisting lateral forces shall be designed and installed by others. No bads are to be applied to the component until after all the framing and fastening are completed. At no lime shall loads greater than design toads be applied to the component. Design Criteria The design and material speed are substantial conformity with the latest revisions of NDS and AITC. Dead toad deflect' ndudes adjustment factor for creep. Total load deflecti is nstamaneou file: C:1Documenls and Settings\Donna Petersen\My NOTE. LOADS SHOWN ARE FOR INPUT LOAD CASE (1). OTHER LOAD CASES FOR PATTERN LIVE LOADING ARE CHECKED AS REQUIRED. (DIMENSIONS MEASURED FROM LEFT END OF SPAN OR CANTILEVER.) DISTRIBUTION SOURCE TYPE TOP /SIDE LOAD FROM FT IN -SX UNIFORM FLOOR LIVE TOP 869 PLF 00 -00 -00 UNIFORM FLOOR DEAD TOP 369 PLF 00 -00 -00 UNIFORM BEAM WEIGHT 6 PLF 00-00 -00 WARNING NOTES: THIS COMPONENT DESIGN IS SPECIFICALLY FOR L -P ENGINEERED WOOD PRODUCTS. USE OF THIS DESIGN FOR ANYTHING OTHER THAN GANG -LAM LVL OR LPI JOISTS IS STRICTLY PROHIBITED. ANY MODIFICATION OF THIS DOCUMENT REQUIRES REVIEW BY A DESIGN PROFESSIONAL MINIMUM BEARING SIZES ARE SUFFICIENT TO PREVENT CRUSHING OF THE GANG -LAM LVL BEAM AS DESIGNED. IT IS THE RESPONSIBILITY OF THE PROJECT ENGINEER, ARCHITECT OR DESIGNER TO VERIFY THAT THE SUPPORT STRUCTURE FOR THIS BEAM IS CAPABLE OF SUPPORTING THE REACTIONS. ANCHOR GANG -LAM LVL FLOOR BEAM SECURELY TO BEARINGS OR HANGERS. 11 875 CROSS SECTION I ,5 250 !Miscellaneous Information The use of this component shall be specified by the design of the complete structure. Odle all the necessary code compliance approval nil instructions from the designers of the complete structure before using this component. If the design aden listed abov does not meet local building code requirements, do not use this design. When this drawing is signed and sealed, the structural design is approved as shown this drawing based on data provided by the custome Gang -Lam LVL and CTR, LPI joists are made without camber and will deflect under load. Wood direct contact with concrete must be protected as required by code. Conti ous lateral upport is assumed (wall, floor beam, etc.). LP does not provide on -site inspection This drawing must hay Architect's or Engineers seal affixed to be considered Englneenng document. LOAD TABLE ry TO FT IN -SX 11 -06 -00 11 -06 -00 11 -06 -00 1 BEAM 5.25 X 11.875 GL2950Fb 2.0E LOAD LDF 1 00 0 90 0 90 11 6- 0 THIS DRAWING IS NOT TO SCALE Gang -Lam LVL and CTR, LPI Joist Specifications Supports and connections for Gang -Lam LVL and CTR, LPI Joists to be specific applications. Common nails driven parallel to glue lines shall be spaced mr mum of 4' for 10d and 3' for ad. Do not cut, otdr, drill r after Gang -Lam LVL and CTR, LPI Joists except as shown published matenal from LP any use of Gang -Lam LVL and CTR, LPI Joists contrary to the limits set forth hereon negates ny express warranty of the product and LP disclaims alt implied wamrnties'nduding the implied warranties of merchantability nd fitness to a particula use. A COPY OF THIS DRAWING IS TO BE GIVEN TO THE INSTALLING CONTRACTOR LP is registered trademark of Louisiana -Pacifi Corporati DocumentslA- PROJECT- FILES12006 ARCHIVE1ARSLAN- 061woode.SPX DWG SHEET Software Provided By LP Engineered Wood Products 2706 Highway 421 North Wilmington, NC 28401 Local 910.762.9878 National Wats 800.999.9105 DESIGN CRITERIA LIVE LOAD DEAD LOAD TOTAL LOAD FLR LEFT SPAN CARR. 0 00 FT FLR RIGHT SPAN CARR. 0 00 FT DEFLECTION CRITERIA LIVE LOAD DEFL TOTAL LOAD DEFL CODE COMPLIANCES REPORT NER 622 ICBO ER -5004 L.A. City RR 25167 CCMC 11518 -R WISCONSIN 200124 -W N Y CITY MEA 97 -94 -E HUD MR 1214D 07/20/07 SBCCI MSI: 0.65 VSI: 0.48 40 PSF 17 PSF 57 PSF L 480 L 240 ARSLAN Y Gl I00 v 2004.2 Allowable Stress Design NOTE. 1. THIS COMPONENT IS DESIGNED TO SUPPORT ONLY THE VERTICAL LOADS SHOWN VERIFICATION OF LOADING, DEFLECTION LIMITATIONS, FRAMING METHODS, WIND AND SEISMIC BRACING, AND OTHER LATERAL BRACING THAT IS ALWAYS REQUIRED IS THE RESPONSIBILITY OF THE PROJECT ENGINEER OR ARCHITECT 2. PROVIDE RESTRAINT AT SUPPORTS TO ENSURE LATERAL STABILITY 3. DO NOT CUT NOTCH OR DRILL LPI FLANGES. 4. SHIM ALL BEARINGS FOR FULL CONTACT 5. VERIFY DIMENSIONS BEFORE CUTTING LPI TO SIZE. 6. THIS LP1 15 TO BE USED AS A FLOOR JOIST ONLY 7 PROVIDE COMPRESSION EDGE BRACING AT 35" O.C. OR LESS. SUPPORT REACTIONS (LBS CASE BEARING NUMBER 1 2 3 1 337 1238 401 2 101 Mr 120 3 391 772 B 9 48 835 936 MIN BEARING SIZES IN- SX) I 1 8 3- 8 1 8 MAXIMUM DEFLECTIONS CALCULATED ALLOWABLE LIVE LOAD 0 18 0 34 *DEAD LOAD 0 08 TOTAL LOAD 0 23 0 68 Handling Erection Temporary and permanent bracing for holding component plumb and for resisting lateral forces shall be designed and installed by others. No loads are to be applied to the component until after all the framing and fastening are completed. At no time shall loads greater than design loads be applied to the component Design Criteria The design and material specified are in substantial conformity with the latest revisions of NDS and ARC. Dead load denecti ncludes adjustment factor to creep. Total load dehedio is instantaneous. NOTE. LOADS SHOWN ARE FOR INPUT LOAD CASE (1). OTHER LOAD CASES FOR PATTERN LIVE LOADING ARE CHECKED AS REQUIRED. (DIMENSIONS MEASURED FROM LEFT END OF SPAN OR CANTILEVER.) DISTRIBUTION SOURCE TYPE TOP /SIDE LOAD FROM TO LOAD FT IN -SX FT IN -SX UNIFORM FLOOR LIVE TOP 53 PLF 00 -00 -00 26-00 -00 UNIFORM FLOOR DEAD TOP 23 PLF 00 -00 -00 26 -00 -00 WARNING NOTES: LOAD TABLE THIS COMPONENT DESIGN IS SPECIFICALLY FOR L-P ENGINEERED WOOD PRODUCTS. USE OF THIS DESIGN FOR ANYTHING OTHER THAN GANG -LAM LVL OR LPI JOISTS IS STRICTLY PROHIBITED. ANY MODIFICATION OF THIS DOCUMENT REQUIRES REVIEW BY A DESIGN PROFESSIONAL MINIMUM BEARING SIZES ARE SUFFICIENT TO PREVENT CRUSHING OF THE LPI JOIST AS DESIGNED. IT IS THE RESPONSIBILITY OF THE PROJECT ENGINEER, ARCHITECT OR DESIGNER TO VERIFY THAT THE SUPPORT STRUCTURE FOR THIS BEAM IS CAPABLE OF SUPPORTING THE REACTIONS. ANCHOR LPI JOIST SECURELY TO BEARINGS OR HANGERS. 9 500 2 500 CROSS SECTION (Miscellaneous Information The use of this component shall be specified by the designer of the complete structure. Obta all the necessary code compli nce approval and instructions from the designers of the complete structure before using this component. If the design often listed abov does not meet local building code requirements, do not use this design When this drawing is signed and sealed, the structural design is approved as shown this drawing lased on data provided by the arstomer Gang -Lam LVL and CTR. LPI joists are made without camber and will defied urtde load. Wood direct contact with concrete must be protected as required by code Continu lateral support is assumed (wall, floor beam, etc.). LP does not provide on-site inspedio This drawing must have Architect's Engineers seal armed to be considered Engineenng document. asr 1 LPI 20 DEPTH 9.500 WEB 0 375 FLANGE 1.50 X 2.50 LDF 1 00 0 90 12 9- 0 26- 0- 0 THIS DRAWING IS NOT TO SCALE Gang -Lam LVL and CTR, LPI Joist Specifications Supports and connections for Gang -Lam LVL and CTR, LPI Joists to be specific applications. Common nails driven parallel to glu lines shall be spaced minimum of 4• fo 10d and 3• for 8d. Do not Cut, notch, drill or alter Gang -Lam LVL and CTR, LPI Joists except as shown published matenal from LP ny use of Gang -Lam LVL and CTR, LPI Joists contrary to the limits set forth hereon,negates any express warranty of the product and LP disdains all implied warranties 'nduding the implied warranties of merchantability and fitness for particula use. A COPY OF THIS DRAWING IS TO BE GIVEN TO THE INSTALLING CONTRACTOR LP is a registered trademark of Louisiana•Pacifh Corporation File: C:1Documents and Settings\Donna Petersen\My DocumentsIA PROJECT FILES12006 ARCHIVE WRSLAN 061woode.SPX 13 8- 0 Software Provided By LP Engineered Wood Products 2706 Highway 421 North Wilmington, NC 28401 Local 910.762.9878 National Wats 800.999.9105 DWG SHEET DESIGN CRITERIA LIVE LOAD 90 PSF DEAD LOAD 17 PSF TOTAL LOAD 57 PSF !SPACING 16 00 IN C/C DEFLECTION CRITERIA LIVE LOAD DEFL TOTAL LOAD DEFL LOAD SHARING 0 CODE COMPLIANCES REPORT ICC -ES ESA -1305 WISCONSIN 200405 -W CCMC 12724 -R L.A. City RR 25099 N Y CITY MEA 101 -00 -E Ye, 07 SBCCI MSI: 0.62 VSI: 0.52 L 480 L 290 S Design Criteria The design and material specified are In ubstantial conformity with the latest revisions of NDS and AITC. Dead load deflecti ncludes adjustment factor for creep Total bad detectio is instantaneous. ARSLAN 2 j rd \oo {C. 2104.2 Allowable Stress Design NOTE. 1. THIS COMPONENT IS DESIGNED TO SUPPORT ONLY THE VERTICAL LOADS SHOWN VERIFICATION OF LOADING, DEFLECTION LIMITATIONS, FRAMING METHODS, WIND AND SEISMIC BRACING, AND OTHER LATERAL BRACING THAT IS ALWAYS REQUIRED IS THE RESPONSIBILITY OF THE PROJECT ENGINEER OR ARCHITECT 2. PROVIDE RESTRAINT AT SUPPORTS TO ENSURE LATERAL STABILITY 3. DO NOT CUT NOTCH OR DRILL LPI FLANGES. 4. SHIM ALL BEARINGS FOR FULL CONTACT. 5. VERIFY DIMENSIONS BEFORE CUTTING LPI TO SIZE. 6. THIS LPI IS TO BE USED AS A FLOOR JOIST ONLY 7 PROVIDE COMPRESSION EDGE BRACING AT 49" O.C. OR LESS. SUPPORT REACTIONS (LBS) CASE B E A R I N G N U M B E R 1 2 3 4 1 315 908 614 139 2 94 271 183 41 3 337 633 279 200 4 72 545 518 18 5 313 920 440 4 6 74 115 I MIN BEARING SIZES (IN -SX) 1 8 3- 8 3- 8 1 8 MAXIMUM DEFLECTIONS CALCULATED ALLOWABLE LIVE LOAD 0 07 0 26' *DEAD LOAD D 04 TOTAL LOAD 0 09 0 52 DISTRIBUTION UNIFORM FLOOR LIVE UNIFORM FLOOR DEAD WARNING NOTES: LOAD TABLE NOTE. LOADS SHOWN ARE FOR INPUT LOAD CASE (1). OTHER LOAD CASES FOR PATTERN LIVE LOADING ARE CHECKED AS REQUIRED. (DIMENSIONS MEASURED FROM LEFT END OF SPAN OR CANTILEVER.) SOURCE TYPE TOP /SIDE LOAD FROM FT IN -SX TOP 53 PLF 00 -00 -00 TOP 23 PLF 00-00 -00 TO LOAD FT IN -SX 26 -00 -00 26 -00 -00 THIS COMPONENT DESIGN IS SPECIFICALLY FOR L -P ENGINEERED WOOD PRODUCTS. USE OF THIS DESIGN FOR ANYTHING OTHER THAN GANG -LAM LVL OR LPI JOISTS IS STRICTLY PROHIBITED. ANY MODIFICATION OF THIS DOCUMENT REQUIRES REVIEW BY A DESIGN PROFESSIONAL MINIMUM BEARING SIZES ARE SUFFICIENT TO PREVENT CRUSHING OF THE LPI JOIST AS DESIGNED. IT IS THE RESPONSIBILITY OF THE PROJECT ENGINEER, ARCHITECT OR DESIGNER TO VERIFY THAT THE SUPPORT STRUCTURE FOR THIS BEAM IS CAPABLE OF SUPPORTING THE REACTIONS. PROVIDE ANCHORAGE FOR UPLIFT AT SUPPORTS INDICATED BY NEGATIVE REACTIONS. ANCHORAGE DETAIL TO BE PROVIDED BY PROJECT ARCHITECT ENGINEER, OR DESIGNER. ANCHOR LPI JOIST SECURELY TO BEARINGS OR HANGERS. 9 500 `12 500 CROSS SECTION Handling 8 Erection (Miscellaneous Information Temporary and permanent bracing to holding component The use of this component shall be specified by the designer of the plumb end for resisting lateral forces shall be designed and complete structure. Obtai all the code compliance approval and instated by others. No loads are to be applied to the instructions from the designers of the complete structure before using this component until after all the fronting and fastening are component. If the design criteria listed abov does not meet local building completed. At no time shall loads greater than design loads code regh... do not use this design When this drawing is signed be applied to the component. and sealed, the structural design is approved as shown this drawing based data provided by the customer. Gang-Lam LVL and CTR, LPI ljoists are made without camber and will deflect unde load. Wood direct contact with concrete must be protected as required by code Continuou lateral support is assumed (wall, floor beam, etc.). LP does not provide on-site rospectio This drawing must have an Architect's E_,...__. seal afixed to be considered an Engr nag document. 10- 6- 4 1 LPI 20 DEPTH 9.500 WEB 0 375 FLANGE 1.50 X 2.50 LOP' 1 00 0 90 new Lena 2 k4 a L 9 -10- 8 ^6- 0- 0 THIS DRAWING IS NOT TO SCALE Gang -Lam LVL and CTR, LPI Joist Specifications Supports and connections for Gang -Lam LVL and CTR, LPI Joists to be speciti applications. Common nails dnven parallel to glu lines shall be spaced a mi mum of 4' fo 10d and 3" for ad. Do not cut, notch, drill or alter Gang-Lam LVL nd CTR. LPI Joists xcept as shown published material from LP any use of Gang -Lam LVL and CTR, LPI Joists contrary to the limits set forth hereo negates ny express warranty of the product and LP disclaims all implied warranties 'nduding the implied warranties of merchantability and fitness for a particular use. A COPY OF THIS DRAWING IS TO BE GIVEN TO THE INSTALLING CONTRACTOR LP is registered trademark of Lo isiana- Pacific Corporation. rile: C:\Documents and Settings\Donna PetersentMy DocumentsVA- PROJECT- FILES12006 ARCHIVEIARSLAN-061woode.SPX Software Provided By LP Engineered Wood Products 2706 Highway 421 North Wilmington, NC 28401 Local 910.762.9878 National Wats 600.999.9105 DWG SHEET J DESIGN CRITERIA pSPACING 16 00 IN C/C DEFLECTION CRITERIA LIVE LOAD DEFL TOTAL LOAD DEFL LOAD SHARING 0 E CODE COMPLIANCES REPORT N ICC -ES ESR -1305 WISCONSIN 200405 -W CCMC 12724 -R L.A. City RR 25099 N Y CITY MEA 101 -00 -E r8 5- 7 4 07/20/07 SBCCI MSI: 0.35 VSI: 0.39 LIVE LOAD 40 PSF DEAD LOAD 17 PSF TOTAL LOAD 57 PSF L 480 L 240 S ARSLAN 2ND FLOOR JOIST 1 2004.2 Allowable Stress Design NOTE: 1. THIS COMPONENT IS DESIGNED TO SUPPORT ONLY THE VERTICAL LOADS SHOWN VERIFICATION OF LOADING, DEFLECTION LIMITATIONS, FRAMING METHODS, WIND AND SEISMIC BRACING, AND OTHER LATERAL BRACING THAT IS ALWAYS REQUIRED IS THE RESPONSIBILITY OF THE PROJECT ENGINEER OR ARCHITECT 2. PROVIDE RESTRAINT AT SUPPORTS TO ENSURE LATERAL STABILITY 3. DO NOT CUT NOTCH OR DRILL LPI FLANGES. 4. SHIM ALL BEARINGS FOR FULL CONTACT 5. VERIFY DIMENSIONS BEFORE CUTTING LPI TO SIZE. 6. THIS LPI IS TO BE USED AS A FLOOR JOIST ONLY 7 PROVIDE COMPRESSION EDGE BRACING AT 25" O.C. OR LESS. SUPPORT REACTIONS (LBS) CASE B E A R I N G N U M B E 1 2 3 1 1671 661 257 2 675 172 77 3 1461 361 286 4 885 972 97 5 855 772 257 6 1701 361 97 MIN BEARING SIZES (IN -SX) I 3- 8 3- 8 1 8 MAXIMUM DEFLECTIONS CALCULATED ALLOWABLE LIVE LOAD -0 17 0 30 *DEAD LOAD -0 16" TOTAL LOAD -0 25 0 59 Handling Erection Temporary and permanent bracing for holding component plumb and for resisting lateral forces stag be designed and installed by others. No loads are to be applied to the component until alto all the framing and fastening are completed. At no time shag loads greater than design loads be applied to the component. Design Criteria The design and matenal specified are substantial conformity with the latest revisions of NDS and ARC. Dead load deflection includes adjustment factor for creep. Total load deflection is instantaneous. R LOAD TABLE NOTE. LOADS SHOWN ARE FOR INPUT LOAD CASE (1). OTHER LOAD CASES FOR PATTERN LIVE LOADING ARE CHECKED AS REQUIRED. (DIMENSIONS MEASURED FROM LEFT END OF SPAN OR CANTILEVER.) DISTRIBUTION SOURCE UNIFORM FLOOR LIVE TOP 90 UNIFORM FLOOR DEAD TOP 17 LINEAR ROOF LIVE TOP 375 LINEAR FLOOR DEAD TOP 255 LINEAR FLOOR LIVE TOP 250 LINEAR FLOOR DEAD TOP 120 LINEAR FLOOR DEAD TOP 106 WARNING NOTES: TYPE TOP /SIDE LOAD FROM TO LOAD LDF FT IN -SX FT IN -SX PLF 00 -00 -00 26 -00 -00 1 00 PLF 00 -00 -00 26 -00 -00 0 90 PLF 00 -00 -00 MINBRG =3 50" 1 15 PLF 00 -00 -00 MINBRG =3 50" 0 90 PLF 00 -00 -00 MINBRG =3 50" 1 00 PLF 00 -00 -00 MINBRG =3 50" 0 90 PLF 00-00 -00 MINBRG =3 50 0 90 THIS COMPONENT DESIGN IS SPECIFICALLY FOR L-P ENGINEERED WOOD PRODUCTS. USE OF THIS DESIGN FOR ANYTHING OTHER THAN GANG -LAM LVL OR LPI JOISTS IS STRICTLY PROHIBITED. ANY MODIFICATION OF THIS DOCUMENT REQUIRES REVIEW BY A DESIGN PROFESSIONAL PROVIDE RESTRAINT AT CONCENTRATED LOAD TO ENSURE LATERAL STABILITY MINIMUM BEARING SIZES ARE SUFFICIENT TO PREVENT CRUSHING OF THE LPI JOIST AS DESIGNED. IT IS THE RESPONSIBILITY OF THE PROJECT ENGINEER, ARCHITECT OR DESIGNER TO VERIFY THAT THE SUPPORT STRUCTURE FOR THIS BEAM IS CAPABLE OF SUPPORTING THE REACTIONS. ANCHOR LPI JOIST SECURELY TO BEARINGS OR HANGERS. LEFT CANTILEVER CALCULATED ALLOWABLE 0 19 0 20" 0 12 0 22 0 30" 11 "v '2 L 2. c 12 65,c 9 500 jc H e1,2 500 CROS: SECTION Miscellaneous Information The use of this component shall be specified by the design of the complete structure. Obtai all the necessary code compliance approval and instructions from the designers of the complete structure before using this If the design criteria listed above does not meet local building code requirements, do not use this design. When this drawing is signed and sealed, the structural design is approved as shown In this drawing based on data provided by the customer. Gang -Lam LVL and CTR, LPI hoists are made without camber and will deflect under bad. Wood direct contact with concrete must be protected as required by code. Continuous lateral upport is assumed (wall, floor beam, etc.). LP does not provide on-site inspection. This drawing must have n Architect's Engineers seal afixed to be considered an Engineering document. 2 0- 0 12 0- 0 1 LPI 20 DEPTH 9.500 WEB 0 375 FLANGE 1.50 X 2.50 STIFFENER REQ STIFFENER REQ STIFFENER REQ STIFFENER REQ STIFFENER REQ 26- 0- 0 THIS DRAWING IS NOT TO SCALE Gang -Lam LVL and CTR, LPI Joist Specifications Supports and connections for Gang -Lam LVL and CTR, LPI Joists to be specific applications. Common nails driven parallel to glue lines shall be spaced minimum of 4" for 10d and 3' for ad. Do not cut, notch, drill or alter Gang -Lam LVL and CTR, LPI Joists except as shown in published material from LP any use of Gang -Lam LVL and CTR, LPI Joists contrary to the limits set forth hereon,negates ny express warranty of the product and LP disclaims all Implied warranties including the implied warranties of merchantability and fitness for a particular use. A COPY OF THIS DRAWING IS TO BE GIVEN TO THE INSTALLING CONTRACTOR LP is registered trademark of Louisiana -Pacific Corporation. Ile: C:1Documents and SettingstDonna Petersen\My DocumentstA- PROJECT- FILES1ARCHIVESt2006 ARCHIVEWRSLAN- 06 1woode.SPX Software Provided By LP Engineered Wood Products 2706 Highway 421 North Wilmington, NC 28401 Local 910.762.9878 National Wats 800.999.9105 DWG SHEET 12 0- 0 DESIGN CRITERIA MSI: 0.78 VSI: 0.86 LIVE LOAD 90 PSF DEAD LOAD 17 PSF TOTAL LOAD 57 PSF 'SPACING 12 00 IN C/C DEFLECTION CRITERIA LIVE LOAD DEFL TOTAL LOAD DEFL L 980 L 290 LOAD SHARING 0 CODE COMPLIANCES REPORT ICC -ES ESR -1305 WISCONSIN 200905 -W CCMC 12729 -R L.A. City RR 25099 N Y CITY MEA 101 -00 -E STIFFENERS REQUIRED REFER TO STIFFENER SPECIFICATION 10/11/07 SBCCI ARSLAN 2ND FLOOR BEAM POST POINT LOAD 2004.2 Allowable Stress Design NOTE: 1 THIS COMPONENT IS DESIGNED TO SUPPORT ONLY THE VERTICAL LOADS SHOWN VERIFICATION OF LOADING, DEFLECTION LIMITATIONS, FRAMING METHODS, WIND AND SEISMIC BRACING, AND OTHER LATERAL BRACING THAT IS ALWAYS REQUIRED IS DISTRIBUTION THE RESPONSIBILITY OF THE PROJECT ENGINEER OR ARCHITECT 2. PROVIDE RESTRAINT AT SUPPORTS TO ENSURE LATERAL STABILITY 3. DO NOT CUT NOTCH OR DRILL GANG -LAM. 4. SHIM ALL BEARINGS FOR FULL CONTACT 5. VERIFY DIMENSIONS BEFORE CUTTING GANG -LAM TO SIZE. 6. THIS GANG -LAM IS TO BE USED AS A FLOOR JOIST ONLY 7 PROVIDE COMPRESSION EDGE BRACING AT EACH END OF COMPONENT DESIGN ASSUMES COMPONENTS CARRIED ARE APPLIED TO TOP EDGE OF GANG -LAM, SUCH THAT LOAD IS DISTRIBUTED EQUALLY TO EACH PLY ATTACH TWO PLIES WITH 2 ROWS OF 16d (3-1/2") NAILS AT 12" DC. FROM ONE FACE ONLY STAGGER ROWS. FLIP BEAM AND ATTACH THE THIRD PLY WITH 2 ROWS OF 16d (3-12") NAILS AT 12" OC TO THE UN- NAILED SIDE OF THE FIRST TWO PLIES. STAGGER ROWS. NAILS MAY BE COMMON OR BOX NAILS WITH A MINIMUM SHANK DIAMETER OF 0.131" 16d SINKERS (3 -1/47 MAY RF I ISFn CONCENTRATED LOADS MUST BE EQUALLY DISTRIBUTED TO ALL PLIES. ADDITIONAL FASTFNFRR MAY PP RFQI IIRFf SUPPORT REACTIONS (LBS) CASE BEARING NUMBER 1 2 3 1 2266 7617 -192 2 913 2959 -83 3 1699 3193 127 9 1480 7928 -352 5 1450 7728 -192 6 2296 7317 -352 MIN BEARING SIZES (IN -SX) 3- 8 3- 8 1- 8 MAXIMUM DEFLECTIONS CALCULATED ALLOWABLE LIVE LOAD 0 09" 0 30' *DEAD LOAD 0 05" TOTAL LOAD 0 13" 0 59" Handling Erection Temporary and permanent bracing for holding component plUITID and for resisting lateral installed by others. No loads are re to b d e applied to designed and co._, until after all the framing and fastening are completed. At no time shaft bads greater Nan design bads be applied to the component. Design Criteria The design and material specified are In substantial conformity with the latest revisions of NDS and ARC. Dead load deflection includes adjustment facto for creep. Total load deflection is instantaneous. LEFT CANTILEVER CALCULATED ALLOWABLE -0 04 0 20' 0 01 0 05 0 30" NOTE: LOADS SHOWN ARE FOR INPUT LOAD CASE (1). OTHER LOAD CASES FOR PATTERN LIVE LOADING ARE CHECKED AS REQUIRED. (DIMENSIONS MEASURED FROM LEFT END OF SPAN OR CANTILEVER.) UNIFORM UNIFORM CONCENTRATED CONCENTRATED LINEAR LINEAR LINEAR LINEAR LINEAR WARNING NOTES: SOURCE TYPE FLOOR FLOOR FLOOR FLOOR ROOF FLOOR FLOOR FLOOR FLOOR 9 500 LIVE DEAD LIVE DEAD LIVE DEAD LIVE DEAD DEAD TOP /SIDE LOAD FROM TO LOAD LDF FT IN -SX FT IN -SX TOP 40 PLF 00 -00 -00 26 -00 -00 1 00 TOP 17 PLF 00 -00 -00 26 -00 -00 0 90 TOP 9292 LBS 12 -04 -00 MINBRG 2 50" 1 00 TOP 2861 LBS 12 -04 -00 MINBRG =2 50" 0 90 TOP 375 PLF 00 -00 -00 MINBRG =2 50" 1 15 TOP 255 PLF 00 -00 -00 MINBRG =2 50" 0 90 TOP 250 PLF 00 -00 -00 MINBRG =2 50" 1 00 TOP 120 PLF 00 -00 -00 MINBRG =2 50" 0 90 TOP 106 PLF 00 -00 -00 MINBRG =2 50" 0 90 THIS COMPONENT DESIGN IS SPECIFICALLY FOR L-P ENGINEERED WOOD PRODUCTS. USE OF THIS DESIGN FOR ANYTHING OTHER THAN GANG -LAM LVL OR LPI JOISTS IS STRICTLY PROHIBITED. ANY MODIFICATION OF THIS DOCUMENT REQUIRES REVIEW BY A DESIGN PROFESSIONAL PROVIDE RESTRAINT AT CONCENTRATED LOAD TO ENSURE LATERAL STABILITY MINIMUM BEARING SEES ARE SUFFICIENT TO PREVENT CRUSHING OF THE GANG -LAM JOIST AS DESIGNED. IT IS THE RESPONSIBILITY OF THE PROJECT ENGINEER, ARCHITECT OR DESIGNER TO VERIFY THAT THE SUPPORT STRUCTURE FOR THIS BEAM IS CAPABLE OF SUPPORTING THE REACTIONS. PROVIDE ANCHORAGE FOR UPLIFT AT SUPPORTS INDICATED BY NEGATIVE REACTIONS. ANCHORAGE DETAIL TO BE PROVIDED BY PROJECT ARCHITECT ENGINEER, OR DESIGNER. ANCHOR GANG -LAM LVL JOIST SECURELY TO BEARINGS OR HANGERS. CROSS SECTION 1 750 3 500 .5 250 LOAD TABLE (Miscellaneous Information The use of this component shall be specified by the designer of the complete structure. Obtain all the necessary code compliance approval and instructions from the designers of the complete structure before using this component. If the design criteria listed above does not meet local building code requirements, do not use this design When this drawing is signed and seated, the structural design is approved as shown in this drawing based on data provided by the customer. Gang -Lam LVL and CTR. LPI joists are made without camber and will deflect under load. Wood direct contact with concrete must be protected as required by code. Continuous lateral support is assumed (wall, floor beam, etc.). LP does not provide on -site inspection. This drawing must have an Architect's or Engineer's seal afixed to be considered Engineering document. 2 0- 0 File: C:lDoaiments and Settings\Donna PetersenWy Documents'A- PROJECT- FILESIARCHIVES12006 ARCHIVEIARSLAN-06 \WOOde.SPX 2.2.c1 CP 14. 12- 0- 0 3 BEAMS 1.75 X 9.500 GL2950Fb 2.0E DESIGN CONSISTS OF 3 PLIES FASTENED TOGETHER (REFER TO NOTES) '6 0- 0 THIS DRAWING IS NOT TO SCALE'"' (Gang -Lam LVL and CTR, LPI Joist Specifications Supports and connections fo Gang-Lam LVL and CTR, LPI Joists to be specific applications. Common nails driven parallel to glu lines shall be spaced a mr mum of 4' fo 10d and 3' for Ed. Do not cut. notch, drill or alter Gang -Lam LVL and CTR, LPI Joists except as shown in published material from LP any use of Gang LVL and CTR, LPI Joists contrary to the limas set forth hereon,negates any express warranty of the product and LP disclaims all implied warranties 'nduding the implied warranties of merchantability and fitness for a particular use. A COPY OF THIS DRAWING IS TO BE GIVEN TO THE INSTALLING CONTRACTOR LP is a registered trademark of Louisiana -Pacific Corporation. DWG SHEET 12 0- 0 DESIGN CRITERIA LIVE LOAD DEAD LOAD TOTAL LOAD !SPACING 12 00 IN DEFLECTION CRITERIA LIVE LOAD DEFL TOTAL LOAD DEFL LOAD SHARING Software Provided By' LP Engineered Wood Products 2706 Highway 421 North Wilmington, NC 28401 Local 910.762.9878 National Wats 800.999.9105 CODE COMPLIANCES REPORT NER 622 ICBO ER -5004 L.A. City RR 25167 CCMC 11518 -R WISCONSIN 200129 -W N Y CITY MEA 97 -94 -E HUD MR 1219D 40 17 57 10/11/07 SBCCI MSI: 0.27 VSI: 0.72 C /C PSF PSF PSF L 980 L 240 0 ARSLAN 2ND FLOOR JOIST 3 2004.2 Allowable Stress Design NOTE. 1 THIS COMPONENT IS DESIGNED TO SUPPORT ONLY THE VERTICAL LOADS SHOWN VERIFICATION OF LOADING, DEFLECTION LIMITATIONS, FRAMING METHODS, WIND AND SEISMIC BRACING, AND OTHER LATERAL BRACING THAT IS ALWAYS REQUIRED IS DISTRIBUTION THE RESPONSIBILITY OF THE PROJECT ENGINEER OR ARCHITECT 2. PROVIDE RESTRAINT AT SUPPORTS TO ENSURE LATERAL STABILITY 3. DO NOT CUT NOTCH OR DRILL LPI FLANGES. 4. SHIM ALL BEARINGS FOR FULL CONTACT 5. VERIFY DIMENSIONS BEFORE CUTTING LPI TO SIZE 6. THIS LPI IS TO BE USED AS A FLOOR JOIST ONLY 7 PROVIDE COMPRESSION EDGE BRACING AT 25' O.C. OR LESS. SUPPORT REACTIONS (LBS) CASE BEARING NUMBER 1 2 3 1 1781 1983 345 2 675 172 77 3 1931 572 935 4 1025 1082 -13 5 965 1593 395 6 1841 972 -13 N MIN BEARING SIZES (IN SX) I 3 8 3- 8 1- 8 MAXIMUM DEFLECTIONS CALCULATED ALLOWABLE LIVE LOAD 0 19" 0 30" *DEAD LOAD -0 21 TOTAL LOAD -0 29 0 59" Handling Erect Temporary and permanent bracing for holding component plumb and for resisting lateral forces shall be designed and installed by others. No loads are to be applied to the component until after all the framing and fastening are completed. At no time shall loads greater than design loads be applied to the component. Design Criteria The design and material specified are substantial conformity with the latest revisions of NDS and ARC. Dead load deflection includes adjustment factor for creep. Total load deflection is instantaneous. UNIFORM UNIFORM LINEAR LINEAR LINEAR LINEAR LINEAR LINEAR LINEAR WARNING NOTES: THIS COMPONENT DESIGN IS SPECIFICALLY FOR L-P ENGINEERED WOOD PRODUCTS. USE OF THIS DESIGN FOR ANYTHING OTHER THAN GANG -LAM LVL OR LPI JOISTS IS STRICTLY PROHIBITED. ANY MODIFICATION OF THIS DOCUMENT REQUIRES REVIEW BY A DESIGN PROFESSIONAL. PROVIDE RESTRAINT AT CONCENTRATED LOAD TO ENSURE LATERAL STABILITY MINIMUM BEARING SIZES ARE SUFFICIENT TO PREVENT CRUSHING OF THE LPI JOIST AS DESIGNED. IT IS THE RESPONSIBILITY OF THE PROJECT ENGINEER, ARCHITECT OR DESIGNER TO VERIFY THAT THE SUPPORT STRUCTURE FOR THIS BEAM IS CAPABLE OF SUPPORTING THE REACTIONS. PROVIDE ANCHORAGE FOR UPLIFT AT SUPPORTS INDICATED BY NEGATIVE REACTIONS. ANCHORAGE DETAIL TO BE PROVIDED BY PROJECT ARCHITECT, ENGINEER, OR DESIGNER. ANCHOR LPI JOIST SECURELY TO BEARINGS OR HANGERS. LEFT CANTILEVER CALCULATED ALLOWABLE 0 12 0 20' 0 10" 0 19" 0 30" LOAD TABLE NOTE. LOADS SHOWN ARE FOR INPUT LOAD CASE (1). OTHER LOAD CASES FOR PATTERN LIVE LOADING ARE CHECKED AS REQUIRED. (DIMENSIONS MEASURED FROM LEFT END OF SPAN OR CANTILEVER.) SOURCE TYPE TOP /SIDE LOAD FROM TO LOAD FT IN -SX FT IN -SX FLOOR LIVE TOP 90 PLF 00 -00 -00 26 FLOOR DEAD TOP 17 PLF 00 -00 -00 26 FLOOR LIVE TOP 690 PLF 10 06 00 MINBRG =3 ROOF LIVE TOP 375 PLF 00 -00 -00 MINBRG =3 FLOOR LIVE TOP 330 PLF 20 06 MINBRG =3 FLOOR DEAD TOP 255 PLF 00 -00 -00 MINBRG =3 FLOOR LIVE TOP 250 PLF 00 -00 -00 MINBRG =3 FLOOR DEAD TOP 120 PLF 00 -00 -00 MINBRG =3 FLOOR DEAD TOP 106 PLF 00 -00-00 MINBRG=3 vl Lt-)T o v2 cc n 9 500 jc r ^1 `1,2 500 CROSS SECTION (Miscellaneous Information The use of this component shall be specified by the designer of the complete structure. Obtain all the necessary code compliance approval and instructions from the designers of the complete structure before using this component. If the design criteria listed above does not meet local building code requirements, do not use this design When this drawing is signed and sealed, the structural design is approved as shown this drawing based on data provided by the customer. Gang-Lam LVL and CTR, LPI joists are made without camber and wit deflect uncle bad. Wood in direct contact with concrete must be protected as requ red by code Continuous lateral support is assumed (wall, floor beam, etc.). LP does not provide on-site inspection. This drawing must have Architect's or Engineer's seal afixed to be considered Engmeenrg document. 2 0- 50" 50" 50" 50" 50" 50" 50" 1 LPI 20 DEPTH 9.500 WEB 0 375 FLANGE 1.50 X 2.50 LDF 1 00 O 90 1 00 1 15 STIFFENER REQ 1 00 O 90 STIFFENER REQ 1 00 STIFFENER REQ 0 90 STIFFENER REQ 0 90 STIFFENER REQ 12 0- 0 26- 0- 0 THIS DRAWING IS NOT TO SCALE*** Gang -Lam LVL and CTR, LPI Joist Specifications Supports and connections for Gang -Lam LVL and CTR, LPI Joists to be specific applications. Common nails driven parallel to glue lines shall be spaced minimum of 4• for 100 and 3• for ed. Do not ad, notch, drill or alter Gang -Lam LVL and CTR, LPI Joists except as shown in published material from LP ny use of Gang -Lam LVL and CTR, LPI Joists contrary to the limits set forth hereon,negates any express warranty of the product and LP disclaims all implied warranties "ncluding the implied warranties of merchantability and fitness fo particular use. A COPY OF THIS DRAWING IS TO BE GIVEN TO THE INSTALLING CONTRACTOR LP is registered trademark of Louisiana Pacific Corporatro 'ile: C:\Documents and SettingslDonna PeterseniMy Documents PROJECT FILESARCHIVES\2006 ARCHIVEWRSLAN 12 0- 0 Software Provided By LP Engineered Wood Products 2706 Highway 421 North Wilmington, NC 28401 Local 910.762.9878 National Wats 800.999.9105 DWG SHEET DESIGN CRITERIA LIVE LOAD 90 PSF DEAD LOAD 17 PSF TOTAL LOAD 57 PSF 'SPACING 12 00 IN C/C DEFLECTION CRITERIA LIVE LOAD DEFL TOTAL LOAD DEFL LOAD SHARING 0 CODE COMPLIANCES REPORT ICC -ES ESR -1305 WISCONSIN 200405 -W CCMC 12724 -R L.A. City RR 25099 N Y CITY MEA 101 -00 -E 10/11/07 SBCCI MSI: 0.80 VSI: 0.86 L 480 L 290 [STIFFENERS REQUIRED REFER TO I STIFFENER SPECIFICATION DEFLECTION ASSUMES COMPOSITE ACTION WITH GLUED AND NAILED 23/32 APA RATED SHEATHING (48/24 SPAN RATING) BOISE Single 6 -3/4" x 12" BOISE GLULAMTM 24F -V4 /DF Floor Beam1FB01 BC CALC® 9.5 Design Report Build 91 Job Name: Address: City State, Zip: Customer Code reports: ICBO 5745, LA 01365 Load Summary Tag Description 1 Standard Load 2 3 4 Controls Summary Pos. Moment Neg. Moment End Shear Cont. Shear Total Load Defl. Live Load Defl. Total Neg. Defl. Max Defl. Span Depth Bearing Supports BO Wall /Plate B1 Post B2 Wall /Plate Page 1 of 1 Value 17251 ft-lbs -24107 ft-lbs -5262 lbs 12058 lbs L/619 (0.244 L/879 (0.172 0.047" 0.244' 12.6 Dim. (L x W) 5 -1/2' x 6 -3/4 6 -3/4 x 6 -3/4' 5 -1/2' x 6 -3/4 Load Type Unf Area (psf) Unf Lin. (plf) Unf Lin. (plf) Conc. Pt. (Ibs) US 2 spans No cantilevers (0/12 slope Thursday October 11 2007 15:20 F) u C) Allowable 53.2% 96.5% 36 8% 84 3% 38.8% 40 9% 94% 24 4% n/a Value 4003 lbs 23561 lbs 7106 lbs Total Horizontal Product Length 26 00 00 Ref. Start Left 00 -00 -00 Left 00 -00 -00 Left 11 -06 -00 Left 11 -06 -00 Duration 100% 100% 100% 100% Allow Support 17 3% 31.3% n/a v 4e; Allow Member 16.6% 796% 29 4% File Name: BC CALC Project Description: FB01 Specifier Designer DONNA J PETERSEN PE Company* 4 SEASONS ENGINEERING INC Misc: End 100% 90% 26 -00 -00 40 10 11 -06 -00 347 232 26 -00 -00 717 478 11 -06 -00 4637 3091 Load Case 16 1 16 1 16 16 16 16 0 1 Cautions Column at Bearing B1 analyzed for bearing only column analysis has not been performed. N otes Design meets Code minimum (L/240) Total load deflection criteria. Design meets Code minimum (0360) Live load deflection criteria. Design meets arbitrary (1') Maximum load deflection criteria. Live Dead Snow Wind Roof Live 115% 133% 125% Trib. 01 -00 -00 n/a n/a n/a Span Location 2 Internal 1 Right 2 Right 1 Right 2 2 1 2 Material Douglas Fir Glulam 24F -V4 Unspecified Disclosure Completeness and accuracy of input must be verified by anyone who would rely on output as evidence of suitability for particular application. Output here based on building code accepted design properties and analysis methods. Installation of BOISE engineered wood products must be in accordance with current Installation Guide and applicable building codes. To obtain Installation Guide or ask questions, please call (888)234 -0056 before installation. BC CALC BC FRAMER® AJST"" ALLJOIST® BC RIM BOARDTm, BCI® BOISE GLULAMT"" SIMPLE FRAMING SYSTEM VERSA -LAM® VERSA -RIM PLUS® VERSA -RIM VERSA STRAND®, VERSA -STUD® are trademarks of Boise Wood Products, L.L.C. IS 4 Seasons Engineering Inc. Project: 911 W 14TH ST Job. ARLAN Client: ARLAN Input Data P4h#0,01EtagiN,C4: Left Cantilever None Check for repetitive use? Yes Dead Load: 17 psf Allow LL Deflection: L/240 Eb. 1600000 psi Design Checks Max. Value Allowable of Allow Location Reactions and Bearing 0' 4'3' vc-1 Lo /T.) 05 WINDOW HEADERS 4'-Roof Beam ftWtOtr 1338.75 2812.69 48? 0' Program Version 8.2 12/17/2004 JubtitatomPioteasionaust Main Span: 4'3' Tributary Width: 15' Live Load: 0 psf Allow TL Deflection: L./180 F. 180 psi 40 1128.53 97 767 1345.5 207 84? 47 3'9-1/2' 21 1/2' A -1 3 :00 4 1T 4„ 1.5 1338.75 1.5 1338.75 Self-weight of member is not included. Member has an actual/allowable ratio in span 1 of 84 11 Design is governed by bending fb/Fb. Governing load combination is Dead+Snow Condition 1 w/Pattern Loads. Maximum hanger forces: 1338.75 lb (Left) and 1338.75 lb (Right). Page 1 08 31:21 07/20/07 Designed by Donna Petersen P E. Checked by Right Cantilever None Slope: 0:12 Snow Load: 25 psf DOL. 1 150 Fb. 900 psi 440 -0.0414 0.2125 19 1, 21 1/2' ft. sirt, -0.0695 0.2833 24 21 1/2' 4 9 47- 06 POST 3RD TO 2ND 4 Seasons Engineering Inc. Project: 911 W 14TH ST Job' ARLAN Client: ARLAN Input Data Span Span 1 Overall Length Notes. Lengths are to center line of bearing. Elevation Angle is 90 deg. Bottom is considered to be pinned. User Defined Loads Load Case Description: Dead Span Axial lb 1 7153.0 Reactions Support 1 2 Load Type Column Load Concentrated Shear Major Axis lb Load Comb. Dead Dead Horizontal Vertical Actual Axial Axial Span Span Length Unbraced Unbraced Length Length Length X Length Y ft ft ft ft ft 0' 8' 8' 8' 0' 0' 8' 8' Shear Minor Axis lb Component Notes. Positive loads act down. Distances are measured along length of member Live loads are patterned to 100 Weight of members is not included in the calculations. Bending Major Axis ft -lb BEAM -Wall Column Page 1 10'03:21 10/11/07 Designed by Donna Petersen P E. Checked by Distance(s) to Start ft Bending Minor Axis ft -lb Load Length ft Axial 8' 7153 Summary of Member Forces Load Combinations Torsion ft -lb Load at Start lb Deflection Major Axis in Horizontal Horizontal Vertical Moment Major Axis Minor Axis Major Axis lb lb lb ft -lb 0.0 0.0 7153.0 0.0 0.0 0.0 0.0 0.0 Load at End lb 0' 0 Deflection Minor Axis in Moment Minor Axis ft -lb 0.0 00 Offset Offset X Y ft ft 2 06 POST 3RD TO 2ND BEAM -Wall Column 4 Seasons Engineering Inc. Project: 911 W 14TH ST Job. ARLAN Client: ARLAN Design Data Material type is No. 2 -Posts Douglas Check for repetitive use? No Moist use? No 1,,= 76.3 in ^4 Sx 27 7 in ^3 Shear Cu 1 Snow Ca= 1 15 Side loaded? No Overstress factor 1 Allowable Floor live load deflection Allowable Floor total load deflection (3 in Maximum) Member weight used in analysis 0 plf I Area 30.25 inA2 Critical Design Checks Critical Axial Reaction psi lb Span 1 Value 0 236.463 Allowable 5156.59 547.973 of Allow 0 it Location 0' 8' Program Version 8.2 12/17/2004 Timber Design 1 Option 1 Check of Member 1 6x6 Check of Member 1 6x6 Fir -Larch -Heavy Timber Top flange bracing is Fully Braced Bottom flange bracing is Fully Braced ly 76.3 in ^4 Sr 27 7 in ^3 This is not a spaced column I Kx= 1 Lx =8' L/360 Ky 1 U240 I Ly 43 Bending X Bending Y psi psi 0 675 0 i 8' 0 675 0 I 8' I E,, 1.3e+06 psi E 1.3e +06 psi G assumed as .06E Shear psi Page 2 1003:21 10/11/07 Designed by Donna Petersen P E. Checked by Fb. 750 psi F,. 475 psi F 700 psi F 625 psi F 170 psi Actual density 35 pcf 0 153 0 i 5 -1/2' LL Deft.. in 0 0.2667 0t 0' L/d I Lid L /d I FcE I F y I FbE I KCE I c Limit I psi psi psi Span 1 I 50 I 17 45 I 0 I 1280.11 I N.A. I le+06 I 0.3 I 0.8 I Member has an actual /allowable ratio in span 1 of 43 V Design is governed by axial fa/Fa. Governing load combination is Dead. Axial capacity of member is 16577 lb. Locations of maximum stress, moment, etc. are measured from the left end of the member Bearing across full width of beam is required. Structural adequacy of supporting members must be confirmed. Bearing lengths required may be limited by bearing stress on supporting members. A negative reaction indicates that the beam must be fastened to the support to resist uplift. See manufacturer's literature for side loaded connection requirements. Cantilever deflection allowables are based on twice the span length. TL Defl. in 0 04 0 0' I CD I C, I C,, I Cy I Cm I Cr I Cr I CE I C,.,, I CD I CT Span 1 I 0.900 I 1.000 I 1.000 I 1.000 I 1.000 I 1.000 I 1.000 I 0.870 I 1.000 I 1.000 I 1.000 I CD I CEb I C14 I CFe I CMb I CM, I CM, I CMU I CMc I CME I RD Span 1 I 1.000 I 1.000 I 1.000 I 1.000 I 1.000 I 1.000 I 1.000 I 1.000 I 1.000 I 1.000 I 0 psi 630 2t 07 LOAD BEARING STUD WALL 8' -Wall Column 4 Seasons Engineering Inc. Project: 911 W 14TH ST Job: ARLAN Client: ARLAN Input Data Span Horizontal Vertical Actual Axial Axial Span Span Length Unbraced Unbraced Length Length Length X Length Y ft ft ft ft ft Span 1 0' 8 8' 8' Overall Length 0' 8' 8' Notes. Lengths are to center line of bearing. Elevation Angle is 90 deg. Bottom is considered to be pinned. User Defined Loads Load Case Load Type Description: Column Load Dead Concentrated Notes. Positive loads act down. Distances are measured along length of member Live loads are patterned to 100 Weight of members is not included in the calculations. Summary of Member Forces Load Combinations Span Axial Shear Shear Bending Bending Torsion Deflection Deflection Major Axis Minor Axis Major Axis Minor Axis Major Axis Minor Axis lb lb lb ft -lb ft -lb ft -lb in in 1 1226.7 Reactions Support 1 2 Component Axial Page 1 1011 48 10/11/07 Designed by Donna Petersen P E. Checked by Distance(s) to Load Load at Load at Offset Offset Start Length Start End X Y ft ft lb lb ft ft 8' 1226.67 0' 0' Load Horizontal Horizontal Vertical Moment Comb. Major Axis Minor Axis Major Axis lb lb lb ft -lb Dead 0.0 0.0 1226.7 Dead 0.0 0.0 0.0 0.0 0.0 Moment Minor Axis ft -lb 0.0 0.0 2 2- 07 LOAD BEARING 4 Seasons Engineering Inc. Project: 911 W 14TH ST Job ARLAN Client: ARLAN Timber Design 1 Option 1 Design of Member 1 2x4 1/2 Design Data Design of Member 1 2x4 a" Material type is No. 2 Douglas Fir -Larch Dimensional Check for repetitive use? No Top flange bracing is Fully Braced Moist use? No I Bottom flange bracing is Fully Braced IY 1 inA4 S,. 1.3 in ^3 This is not a spaced column Kx 1 Lx =8' Ky 1 L l 5 4 inA4 S% 3.1 in ^3 Shear CH 1 Snow Cd 1 15 Side loaded? No Overstress factor =1 Allowable Floor live load deflection L/360 Allowable Floor total load deflection U240 (3 in Maximum) Member weight used in analysis 0 plf Critical Design Checks Span 1 Value Allowable of Allow Location Critical Reaction lb Axial psi 0 233.651 1406.34 562.288 0S' 42 le 0' 0' STUD WALL 8' -Wall Column Page 2 10 48 10/11/07 Designed by Donna Petersen P E. Checked by Area 5.25 in '2 Bending X Bending Y psi psi 0 1215 0 0' 0 1215 0 0' Shear psi Ebx 1.6e+06 psi Eb 1.6e+06 psi G assumed as .06E Fb. 900 psi F 575 psi F. 1350 psi F1 625 psi F 180 psi Actual density 35 pcf 0 162 0it 3 -1/2' LL Deft. in 0 0.2667 0 0' TL Defl. in 0 0.4 0V 0' Co I C1 I CL I Cv I Crd I Cr I Cr I Cr, I Crr I CH I Cr Span 1 0.900 I 1.000 I 1.000 I 1.000 I 1.000 I 1.000 I 1.000 I 0.402 I 1.000 I 1.000 I 1.000 I Cb I CH, I C11 I CRC I CMb I CMt I CMv I Coda I CMc I CME I Rb Span 1 I 1.000 I 1.500 I 1.500 11 150 I 1.000 I 1.000 I 1.000 I 1.000 I 1.000 I 1.000 I 0 F` psi 0.3 I 0.8 I 1397.25 L/d I Lid I L /d I Fee I FcE y I FbE Kce I c Limit psi psi psi Span 1 I 50 I 27 43 I 0 I 638.021 I N.A. I le+06 Member has an actual/allowable ratio in span 1 of 42 Y Design is governed by axial fa/Fa. Governing load combination is Dead. Axial capacity of member is 2950.5 lb. Locations of maximum stress, moment, etc. are measured from the left end of the member Bearing across full width of beam is required. Structural adequacy of supporting members must be confirmed. Bearing lengths required may be limited by bearing stress on supporting members. A negative reaction indicates that the beam must be fastened to the support to resist uplift. See manufacturer's literature for side loaded connection requirements. Cantilever deflection allowables are based on twice the span length. Program Version 8.2 12/17/2004 4 Seasons Engineering Inc. Project: 911 W 14TH ST Job. ARLAN Client: ARLAN Check for repetitive use? Yes Dead Load: 10 psf Mow LL Deflection: U360 Eb. 1300000 psi Design Checks Max. Value 2500 Allowable 2525.39 ')/0 of Allow. Location Reactions and Bearing :(ti14-0k 0' 10' 20' Program Version 8.2 12/17/2004 08 DECK BEAM-Floor Beam Input Data 8(NH 1/1 Left Cantilever None Main Span: 10' Main Span: 10 Right Cantilever None Tributary Width: 4' Live Load: 40 psf Allow TL Deflection: L/240 (3 in Maximum) F. 150 psi 10 99? 10' _A? -978.427 1086.99 90 If 10' Self-weight of member is not included. Member has an actual/allowable ratio in span 1 of 90 VW Design is governed by bending fb/Fb. Governing load combination is Dead+Floor Live w/Pattern Loads. Maximum hanger forces: 850 lb (Left) and 850 lb (Right). 850 2500 850 'I. 66.81 150 45? 9'4-3/4' Page 1 11 35 43 10/11/07 Designed by Donna Petersen P E. Checked by Slope: 0 Snow Load: 0 DOL. 1.000 Fp. 850 psi -0.175 -0.2006 0.3333 0.5 52? 4�? 47-25/32' 47-25/32' 2 09 WINDOW HEADER WITH POINT LOAD-Quick Beam 4 Seasons Engineering Inc. Project: 911 W 14TH ST Job: ARLAN Client: ARLAN Input Data ktrifflit Left Cantilever None Check for repetitive use? No Dead Load: 0 psf Allow LL Deflection: L/360 Eb. 1800000 psi User Defined Loads Dead Dead Snow Condition 1 Design Checks Max. Value 6490.5 Allowable 6556.4 of Allow Location Reactions and Bearing 0' 5'6' Uniform Concentrated Uniform 99 V Program Version 8.2 12/17/2004 4 Main Span: 5'6" Tributary Width: 0' Live Load: 0 psf Allow TL Deflection: L/240 (3 in Maximum) F 240 psi 0' "IkEr1,4 1.968 1.5 ,176 4 1075.12 2160 5� 1/ Self-weight of member is not included. Member has an actuaVallowable ratio in span 1 of 93 Design is governed by shear fv/Fv Governing load combination is Dead. Maximum hanger forces: 6490.5 lb (Left) and 1968.5 lb (Right). Ati6JANitar* 1 144.; Right Cantilever None Slope: 0 Snow Load: 0 DOL. 0.900 0' 1 0' 6490.5 1968.5 Page 1 15:2601 10/11/07 Designed by Donna Petersen P E. Checked by Fp. 2400 psi 6' 171 7106 6' 75 atrW 200.195 216 93 V 9' 7 ir Ofdli r -0.0027 -0.0493 0.1833 0.275 1 V 17b 25-3/8' 2'5-3/8' 2 Garage /ADU Structural Design for Emanuel Arslan Yitt-t it W NI+ 54-- Port Angeles, WA 98363 I'3 O l ExPIREs J 0') FILE 4 SEASONS ENGINEERING, INC 619 SOUTH CHASE STREET PORT ANGELES, WA 98362 A 4 SEASONS ENGINEERING, INC Jim Lierly City of Port Angeles Building Official PO Box 1150 Port Angeles, WA 98362 Subject: Scope of Engineering for 1 Lateral Forces 2. Beams and Headers 3 Foundation Please give me a call if you need any additional information Sincerely Donna J Structural Design Emanuel Arslan 1118 W 7th Street Port Angeles, WA 98363 etersen P E. (360) 452 -3023 Fax (360) 452 -3047 619 S. Chase Street Port Angeles, WA 98362 Enclosed is the structural design of the Garage /ADU for Emanuel Arslan February 13, 2006 At this time, portions of this structure that have been reviewed by the engineer include Structural Design Emanuel Arslan 1118 W 7th Street Port Angeles, WA 98363 DESIGN CRITERIA ELEVATION LESS THAN 625 FT SNOW LOAD GROUND= 25 PSF SNOW ROOF 25 PSF LIVE LOAD 40 PSF (FLOOR) DEAD LOAD 10 PSF (FLOOR) DEAD LOAD =10 PSF (ROOF) DEAD LOAD 7 PSF (CEILING) WIND SPEED, VFM 80 MPH 3 SEC GUST, Vas 100 MPH EXPOSURE C SEISMIC ZONE D2 SOIL BEARING 1500 PSF REFERENCES (1) (3) (4) (5) (6) DESIGN STRESSES DOUGLAS FIR/LARCH #2- 2 4 x Fb 900 PSI F 95 PSI E= 1 6 (10) PSI DOUGLAS FIR/LARCH #1- 2 4 x Fb 1200 PSI F 95 PSI E= 1.8 (10) PSI HEM FIR #2 -2 &4 Fb 850 PSI F 75 PSI E= 1.3 (10) PSI GLU -LAM BEAMS 24F -V4 Fb= 2400 PSI (T) BOTTOM Fb= 1850 PSI (T) TOP F =165 PSI E= 1.8 (10) PSI INTERNATIONAL BUILDING CODE 2003 INTERNATIONAL RESIDENTIAL CODE 2003 TIMBER CONSTRUCTION MANUAL 3RD ED by AITC CONNECTORS FOR WOOD CONSTRUCTION by SIMPSON STRONG -TIE WESTERN WOODS USE BOOK by WESTERN WOOD PRODUCTS ASSOCIATION MAY 1996 NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION 1997 ROSBORO -APA WOODCAD, VERSION 1 1 by ROSBORO GLULAM RESOURCES 2000 RISA -2D RAPID INTERACTIVE STRUCTURAL ANALYSIS 2- DIMENSIONAL VERSION 5.5 2001 General Notes 1 Ground snow load 25 PSF roof snow load 25 PSF 2. Maximum soil bearing capacity 1500 PSF 3. Seismic Zone D2. 4. Wind, VFM 80 MPH, 3 second gust, Vas 100 MPH, Exposure 'C' 5. Notations on drawing relating to framing clips, joist hangers and other connecting devices refer to catalog numbers of connectors manufactured by the Simpson Strong -Tie Company San Leandro, CA. Equivalent devices by other manufacturers may be substituted, provided they have ICBO approval for equal load capacities. 6. Roof Trusses: Trusses shall be designed by the manufacturer and design calculations shall be submitted for approval prior to fabrication. Each wood truss shall carry a grading stamp. Top chord members shall be sized to accommodate roof snow load and appropriate snow drifts as noted in the IBC. No field modification of trusses will be allowed without the engineer's approval. Live load truss deflection shall be limited to L/360. Total load deflection will be limited to U240. 7 Girder trusses shall be attached to wall framing with Simpson LGT2, minimum 2000 pounds uplift, or equal. 8. Contractor shall provide temporary bracing and shoring for the structure and structural components until all final connections have been completed in accordance with the plans. 9. Contractor shall be responsible for all the required safety precautions and methods, techniques, sequences or procedures required to perform his work. 10. Contractor initiated changes shall be submitted in writing to the structural engineer for approval prior to fabrication or construction. 11 Drawings indicate general and typical details of construction, where conditions are not specifically indicated but are of similar character to details shown, similar details of construction shall be used. General Concrete Notes (The Following apply unless shown on the plans) 1 All materials and workmanship shall conform to the requirements of the drawings, specifications, and the 2003 International Residential Code. 2. Concrete shall attain a 28 day strength of F'c= 2500 psi, 5 1/2 sacks of cement per cubic yard of concrete. 3. Reinforcing steel shall conform to ASTM A615 -76A, Grade 40, fy= 40,000 psi. 4. Reinforcing steel shall be detailed (including hooks and bends) in accordance with 30 bar diameters or 2' -0' minimum. Provide corner bars in all wall Intersections. Lap corner bars 30 bar diameters or 2' -0' minimum. 5. Lap adjacent mats of welded wire mesh one full mesh at sides and ends. 6. No bars partially embedded in hardened concrete shall be field bent unless specifically so detailed or approved by the structural engineer 7 Concrete protection (cover) for reinforcing steel shall be as follows: Footings and other unformed surfaces: earth face 3' Formed surfaces exposed to earth, walls below ground, or weather. #6 bars or larger 2' #5 bars or smaller 1 1/2' Walls interior face 3/4' 8. Footings shall bear on solid unyielding natural earth free of organic material 4- Single story structures Two story structures Three story structures 9. Slabs shall be placed upon compacted granular fill, 2' minimum thickness. 1 12' below original grade 18' below original grade 24' below original grade Wood Framing Notes (The Following apply unless shown on the plans) All wood framing details not shown otherwise shall be constructed equal to or better than the minimum standards of the 2003 I.R.C. 2. Minimum nailing requirements: Unless otherwise noted, minimum nailing shall be in accordance with Table R602.3(1) of the 2003 I.R.C. 3. All structural framing lumber such as 2x_ joists, and rafters to be Douglas Fir No. 2, Spruce /Pine /Fir No. 2, or Hem /Fir No. 2 kiln dried. 4. All 2x_ studs and blocking to be Douglas Fir construction, Spruce /Pine /Fir construction, or Hem /Fir construction grade. 5. All structural posts to be Douglas Fir No. 2. 6. All structural headers to be 4x_ Douglas Fir No. 2. 7 All Glu -lam beams to consist of Douglas Fir kiln dried 24F -V4 standard grade unless noted otherwise on plans. 8. All 2x framing lumber exposed to weather and /or moisture shall be Hem -Fir No.2, pressure treated in accordance with the American Wood Preservers Association standard for above ground use. 9. All 4x and 6x structural lumber exposed to weather and /or in ground contact shall be Hem -Fir No.2, pressure treated in accordance with the American Wood Preservers Association standard for ground contact use. 10. Framing connectors, nails, bolts, and other fasteners in contact with pressure treated wood shall have the following finishes: _Wood Treatment CCA -C and DOT Sodium Borate (SBX) I ACQ -C, ACQ -D, CBA -A, CA -B, Other Borate (Non -DOT) Steel Ammoniacal Copper Zinc Arsenate (ACZE) and other pressure treated woods. I Finish I Galvanized, 0.60 oz/fe i Post Hot -Dip Galvanized, ZMAX galvanized, 1.85 oz/ft or SST300- Stainless Steel SST300- Stainless Steel 11 When using Stainless Steel or hot -dip galvanized connectors, the connectors and fasteners should be made of the same material. Stainless Steel fasteners shall not be use in applications where contact with Galvanized and Post Hot -Dip Galvanized metals will occur 12. Individual members of built -up posts and beams shall each be attached with 16d spikes at 12' o.c. staggered. 13. All columns in framed walls to be well nailed into adjacent framing in order to resist lateral movement. 14. Provide solid blocking for wood columns and multiple studs through floors to supports below. 15. Provide 4x10 headers, or double 2x10 headers over and double studs each side of all openings in stud bearing walls not detailed otherwise. 16. Provide 4x8 headers, or double 2x8 headers over and double studs each side of all openings in non structural stud walls not detailed otherwise. 17 At joist areas: Provide solid blocking at bearing points and at intermediate bearing locations. Provide double joists under all load bearing partitions. Provide double joists each side of openings unless detailed otherwise. 18. Provide double joist headers and double joists each side of all openings in floors and roofs unless detailed otherwise 19. Toenail joists to supports with 2 -16d nails, 2 -10d box nails for TJI joists. 20. Attach joists to flush headers and beams with Simpson 'U' series metal joist hangers to suit the joist size. 21 All wood stud walls shall have lower wood plate attached to wood framing below with 16d nails at 12' o.c. staggered, unless otherwise noted In the shearwall schedule. 22. Plywood roof and floor sheathing unless otherwise noted on plan shall be laid up with face grain perpendicular to supports and nailed with 8d nails 6' o.c. to framed panel edges and over stud walls shown on the plans 12' o.c. to intermediate supports. Provide approved plywood clips 16' o.c. at unblocked roof sheathing edges. Provide solid blocking at lines of support at floors. Toenail blocking to supports with 16d 12' o.c. unless otherwise noted in the shearwall schedule. 23. Provide continuous solid blocking at mid height of all stud walls over 10' in height unless wall is blocked per shear wall note. 24. Plywood wall sheathing for noted shear walls shall have solid blocking at all sheathing panel edges. See shear wall schedule for further notes. Mark Sheeting Fastener spacing 0 all edges (Blocked) 7/16" OSB 8d 0 6" OC O OR 15 GA 04" OC 7/16" OSB 8d 0 4" OC OR 15 GA 03 OC 1/2" CDX plywood 1/2" CDX 10d 0 3" OC plywood 1/2' CDX plywood 1/2" GWB both sides 5/8" GWB both sides Notes: 2. 3. 6. 7 10d 0 2" OC ARSLAN SHEARWALL NOTES 8d 0 3" 00 OR 15 GA 0 2 -1/2" OC 5d COOLER 0 4" OC OR 5d GWB O4 OC 6d COOLER 0 4" OC OR 6d GWB 04 "OC SHEAR WALL SCHEDULE 1. 7 Bottom plate noising Framing doubled stud solicina size Sheeted Sheeted I one side I both sides Intermediate framing nail spacing 8d 0 6" OC for stud framing 0 24" 8d 0 12" OC for stud framin 016" 8d 0 6" OC for stud framing 0 24' 8d 012 "OC for stud Taming 0 16" 8d06 "OC for stud framing 024" 8d 0 12" OC for stud framing 0 16" backing 10dO6 "OC for stud flaming 0 24" 10d 012 OC for stud framing 0 16" 10d 0 6" 00 for stud flaming 0 24' 10d 012 OC for stud framing 016' 5d cooler 0 4" OC 2x 5d GYM 04 "OC 6d cooler 0 4" OC 2x 6d GWB O 4" OC ALL SHEAR PANELS SHALL BE BLOCKED. 3x or DBL.2x 3x or DBL.2x 3x or DBL.2x 1. ALL NAILS SHALL BE GALVANIZED BOX NAILS OR COMMON 8d common 0.131 dia X 2 -1/2 "min. 10d common 0.148 "dia X 3 min. 8d box 0.113 dia X 2 -1/2"min. 10 box 0.128 "dio X 3 "min. 15 GA. staple =0.072 "dia X 1 -1/2" min. 4SEASONS Anchor Bolts I Sheeted I Sheeted one side both sides Maxiumum allowble shear 2x 240 PLF 2 -16d 0 2 -16d 0 1/2" X10" 5/8" X10" 480 PLF 12 "OC 8 "OC 048" 0.0. 0 30" 0.C. 2x 350PLF 2,3,5,6 2 -16d 2 -16d 0 5/8" X10" 5/8" X10" 700 PLF 10 "OC 5 "OC 040" 0.C. 0 20"0.C. 490 PLF 2 -16d 2 -16d 0 5/8" X10" 5/8" X10" 980 PLF 0 7"0C 3- 1/2`OC 0 28" 0.0. 0 14" 0.0. 600 PLF 2 -16d 2 -16d 0 5/8 "X10" 5/8" X10" 1200 PLF 0 6 "OC 3 "OC 024" O.C. 0 12" O.C. 3 -16d 3 -16d 0 5/8" X10" 5/8" X10" 0 6 3 "OC 018" O.C. 0 9" O.C. 2 -16d 0 5/8" X10" 12 "OC 0 48" 0.C. 2 -16d 0 5/8 "X10" 10 "0C 0 36" O.C. NAILS, F TE �H�1 EE,I HI FQL9WiNG CRITERIA: 5d G149 0.086 dia X 1 -5/8 min. 6d cooler !0.092 "dia X 1 -7/8' min. 6d GWB 0.092`dia X 1 -7/8" min. 16d common 0.162 "dia X 3 -1/2" min. 770 PLF 1540 PLF 300 PLF 375 PLF Notes PROVIDE APA RATED SHEATHING PLYWOOD OR OSB APA RATED SIDING 303 OF INNER SEAL OSB RATED PANEL SIDING ON ALL EXTERIOR WALLS AND NAIL PER NOTE 1. SPECIFIED SHEATHING AND SIDING PANEL EDGES SHALL BE BACKED WITH 2" OR 3' FRAMING (PER THE TABLE) INCLUDING FOUNDATION SILL PLATES, VERTICAL FRAMING, AND BLOCKING. PANELS MAY BE INSTALLED EITHER HORIZONTALLY OR VERTICALLY (SEE NOTE 4 FOR EXCEPTION). NAILS SHALL BE STAGGERED FOR 3" FRAMING. 4 7/16" OSB MAY BE SUBSTITUTED FOR 1/2" CDX PLYWOOD IF FRAMING IS SPACED AT 16" ON CENTER, OR PANELS ARE APPLIED WITH LONG DIMENSION ACROSS STUDS FOR FRAMING SPACED AT 24' (BLOCKED). 5 WHERE PANELS ARE APPLIED ON BOTH FACES OF A WALL AND NAIL SPACING IS LESS THAN 6 INCHES ON CENTER ON EITHER SIDE, PANEL JOINTS SHALL BE OFFSET TO FALL ON DIFFERENT FRAMING MEMBERS OR FRAMING SHALL BE 3 —INCH NOMINAL AND NAILS ON EACH SIDE SHALL BE STAGGERED. NAILS TO BE DRIVEN FLUSH WITH SHEATHING. DO NOT OVER DRIVE NAILS. 2. 3, 6 2, 3,4,5,6 2, 3, 4, 5, 6 2,3,5,6 3, 6 3, 6 DATE. FEBRUARY 2006 I SCALE. NONE DRAWN BY DJP ENGINEERING, INC (360) 452 -3023 I CHECKED 619 S. Chase St. Port Angeles, WA 98362 1 SHEET. '7 Garage /ADU Emanuel ROlanY 1.118 "'VV 7th ::Street; Port Angeles WA.9836a 2003 IBC WIND ANALYSIS BUILDING DESCRIPTION FIRST FLOOR SECOND FLOOR ROOF HEIGHT AVERAGE HEIGHT OF BUILDING A 1 2.6 3 WIND EXPOSURE IC WIND SPEED 1100 MPH ROOF PITCH (4 41 P XIWP93o P 2 Iwps3o i I I AREA A. Pao 1.281 1' AREA B, ps30 1.28 1 AREA C ps30 1.28 1 AREA D ps30 1.28 1 AREA E, ps30 1.28 1 AREA F ps30 1.28 1 AREA G, ps30 1.28 1 AREA H, ps30 1.28 1 E oh 1.28 1 G oh 1.28 1 COMPONENTS AREA 60 ZONE 1, 100sgft 1.28 1 ZONE 2, 100 sqft 1.28 1 ZONE 3, 100sgft 1.28 1 EAVES Z3 1.28 1 121 18.431 LC1 Pao LC1,P .LC 22 28.07 22 -5.81 7 40 -5.8 14.61 18.63 14.6 -3.2 -4.08 3.2 19.1 -24.37 19.1 13.3 16.97 13.3 13.3 16.97 13.3 10.1 12.89 10.1 -26.7 -34.07 -26.7 -20.9 -26.67 -20.9 WIDTH LENGTH LEAST DIM 26 it 301 261 2 19 3 2A =1 6.0 18.50 -26.79 42.36 -48.61 -8.50 16.79 -32.36 -38.61 1 )03 IBC SEISMIC ANALYSIS SIMPLIFIED BASE SHED S1 I 0.50 Ss 1.25 SITE CLASS D Fv 1.50 Fa 100 Sm1 0.75 Sms 1.25 Sd1 I 0.50 Sds 0.83 SEISMIC USE GROUP I 1 SEISMIC DESIGN CATEGORY D LC2,P RESPONSE MODIFICATION FACTOR I 6 1/2 28.07 SEISMIC BASE SHEAR COEFFICIENT 0.154 7 40 CONNECTION OF SMALL ELEMENTS 18.63 SHEAR COEFFICIENT= 0.111 -4.08 HORIZONTAL DIAPHRAGMS -24.37 SHEAR COEFFICIENT= 0 1667 16.97 BEARING AND SHEAR WALL 16.97 OUT OF PLANE WALL FORCES 12.89 SHEAR COEFFICIENT= 0.3333 -34.07 MASONRY AND CONCRETE OUT OF PLANE -26.67 SHEAR COEFFICIENT= 0.6667 119.007ILONGEST TRUSS 2 FT OC 26 201.525 EAVES 2 ROOF DEAD LOAD '10, 154 446ITRUSS UPLIFT 475 HURRICANE CLIP JH1 5 Garage/ADU Emanuel Ars lan 1118 7th Street Port Angeles, WA 98363 WALL SECOND WALL A WALL B WALL C WALL D WALL I TRIB MAIN I AREA WALL A k B D WALL B A B C D WALL C A B C D WALL D A B C LATERAL FORCE RESISTING SYSTEM WIND LOADS (AREA)(PRESSURE)/LENGTH SHEAR TRIB WIDTH I HEIGHT PS FORCE AREA FT I FT PSF LBS A 28.07 B t 740 C 0 18.63 -4 08 1620.3 A 80 I 51 28.07 B 7 40 C S2.0' 18.63 -4.08 1620.3 A 80 I 40 28.07 B 80 V 43. 7 40 C 70 I 4:0c i 18.63 o 90 V 43.. -4.08 1331.0 A 80 I 40 28.07 B 80 I 43 7 1 18.63 D 9Q t 4 3 -4.08 1331 0 LATERAL FORCE RESISTING SYSTEM WIND LOADS (AREA)(PRESSURE)/LENGTH SHEAR WIDTH HEIGHT PS FORCE LENGTH FT FT PSF LBS FT 80 I 152 28.07 L 7 50 I 15,2; 18.63 -4.08 4829.0 80 152 1.. I 7 40 18.63 -4.08 4829.0 &oIL,1j'3.o1. 28.07 I.. .4:3 7 18.63 I 4 1 0 .Y1 -4.08 4201.8 28.07 80 i 43 7 70 I 130 18.63 40 1 43 -408 I 4201.8 LENGTH I SHEAR FT I PLF QLI 0 .24 TRIB AREA ROOF FLOOR WALL 54.0 !ETC ROOF FLOOR WALL 54.0 ETC. ROOF FLOOR WALL 51.2 ETC. ROOF FLOOR WALL 51.2 ETC. SHEAR TRIB PLF AREA !ROOF FLOOR WALL 161.0 ETC. ROOF FLOOR WALL 161.0 !ETC. ROOF FLOOR WALL 175.1 ETC. ROOF FLOOR WALL 175.1 !ETC. WIDTH I DL SHEAR FT I PSF COEFF I:, 17 17.0 I 17 :8'4= tl. I 0.154 SEISMIC LOADS WIDTH I DL FT I PSF 170 I ':17 A40 17 80 I 8 80 I 8 80. ry 80 1,,, 8 J19.6' 15.0 2 17 1 1 18:6 [,:_;1„7_; 160 Vii SEISMIC LOADS 0.154 0 154 0.154 SHEAR COEFF 0.154 0.154 0.154 0.154 SHEAR LBS 1629.2 1629.2 1588.8 1588.8 SHEAR LBS 3023.1 2866.2 2644 4 2644 4 SHEAR PLF 54.3 54.3 61 1 61 1 SHEAR PLF 100.8 95.5 110.2 110.2 3 Garage/ADU Emanuel Ars Ian 1118W 7th Street Port Angeles, WA 98363 PERFORATED SHEAR WALL DESIGN I I IWALL DL IROOF DU FLOOR DI.: I I I I I I I I I I I 1E2 71$7.L1:::- .471:12,:),,:l15 Level I I I I I I I I I I I SECOND I I WIND I SEISMIC I OVERALL I MINIMUM PIER I I RESISTANCE I DESIGN I SHEAR I TRIB I TRIB I I WALL I SHEAR I SHEAR I HEIGHT' WIDTH I HEIGHT' WIDTH IMAX OPENING' OF WALL I OF FULL ADJUSTMENT I SHEAR I WALL I ROOF I FLOOR I UPLIFT PANEL' 54.0 54.3 30 PLF PLF FT FT FT FT HEIGHT (FT.) HEIGHT HEIGHT SHTHG. FACTOR PLF TYPE FT FT LBS. WALL A I A I 48.5 48.8 8 I 261 V I 4 50 I 054 0.81 111.6 1 7... ..:i.k.... 1, 1 0.0 B 89.8 90.3 8 4.1: 1 -F 0 1 0 1o0 J 1.00 90.3 1 t 1 A 368.5 WALL B I I 54.0 54.3 I I 301 I I I I I I I I A 45.0 45.3 8 36 0: ......_..i l i 0 1 .00: 1.00 45.3 1 i k I 1 „,:),At-; 00 WALL C I I 51.2 61 1 I I 261 I I I A 37.0 44.1 8 16 1 l' :I' -9i1 0 TOp 1 00 44.1 1 WALL D 1 I 51.2 61 1 I 261 i I I A I 51.2 61 1 I 8 I ....:,....'201. "...1.',.. 7.;1.; ..:;67?-1::.: 0 ..11661.1",2f: 1.00 61 1 1 B 51.2 61 1 8 ..7 6 r....:,.TF 7 'IT 0 1:00 J 1.00 61 1 1 WIND I RESISTANCE DESIGN SHEAR TRIB I TRIB I WALL I SHEAR SHEAR I HEIGHT OF WALL OF FULL ADJUSTMENT SHEAR WALL ROOF 1 FLOOR I UPLIFT PANEL' PLF PLF I FT HEIGHT HEIGHT SHTHG. FACTOR PLF TYPE FT I FT I LBS. WALLA I 161.0 100.8 I I I A I 5962 373.2 8 0 "..i.._ ....Yd.& 1.00 425.8 3 4457.5 B I 5962 373.2 I 8 0 109. 1.00 425.8 3 F...:6':. :A 4457 C I 596.2 373.2 I 8 0 11A; 1.00 425.8 3 „15: r 1 44575 161.0 95.5 A 161.0 95.5 8 38 175.1 110.2 A 175.1 110.2 8 o top: v.-. 175.1 110.2 A 210.1 132.2 8 I 0 '1:00 Level MAIN WALL B WALL C 1 WALL D 1 I I I SEISMIC OVERALL I MINIMUM PIER I WIDTH I HEIGHT' WIDTH MAX OPENING FT I FT I FT I HEIGHT (FT.) 301 1 301 1 1 1' .30 241 I I 241 1 1 2 0 1 0.0 1 0.0 325.1 1 0.98 147.0 1 1 1 0.0 I I I 1.00 125 1 637.4 1.00 150.1 1 3 1044.7 BOISE BC CALC® 9.2 Design Report US Build 141 Job Name. Address. City State Zip' Customer Code reports. ARSLAN 1118 W 7TH STREET PORT ANGELES, WA 98363 ARSLAN ESR 1336 11111111111 y� 02 -00 -00 12 -00 -00 B1 3 -1/2' LL 398 lbs DL 667 lbs SL 604 lbs Load Summary Tag Description 1 Standard Load 2 Controls Summary Pos. Moment Neg. Moment End Reaction Int. Reaction Cont. Shear Total Load Defl. Live Load Defl. Total Neg. Defl. Max Defl. Span Depth Page 1 of 1 Value 1045 ft-lbs 2003 ft-lbs 394 lbs 1646 lbs 1066 lbs 2xU270 (0 177 2xU427 (0 113 -0 132' 0 177' 15.2 Bearing Supports Dim. (L x W) B1 Beam 3 -1/2' x 2' B2 Beam 3 -1/2' x 2' B3 Wall /Plate 2 1/2' x 2' Single 9 -1/2" BCI® 5000 -1 7 DF 3 spans I Left cantilever 1 0/12 slope 16' OCS I Repetitive I Glued nailed construction File Name: BC CALC Project Description: J01 Specifier Designer' DONNA J PETERSEN PE Company' 4 SEASONS ENGINEERING INC Misc: __1_1 1 1.1 1 1 1 1 1 1 1, 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Load Type Unf Area Conc. Lin. Ref. Left Left Allowable 42.5% 70 8% 41 4% 68.2% 62.9% 66.6% 56.3% 26.3% 177% n/a Value 1668 lbs 1021 lbs 431 lbs Cautions Design assumes Top and Bottom flanges to be restrained at cantilever B2, 3 -1/2' LL 795 lbs DL 225 lbs Total Horizontal Product Length 26 -00 -00 Live Dead 100% 90% 40 psf 17 psf 319 plf Start End 00 -00 -00 26 -00 -00 00 -00 -00 00 -00 -00 Duration Load Case 100% 14 115% 17 100% 14 115% 17 115% 17 13 13 13 13 Allow Allow Support Member 31.8% n/a 19 4% n/a n/a n/a r �*r B3, 2 1/2' LL 287 lbs DL 123 lbs SL 21 lbs Span Location 3 Internal 1 Right 3 Right 1 Right 1 Right 1 Cantilever 1 Cantilever 2 1 Cantilever 2 Material Versa -Lam 1 7 Versa -Lam 1 7 Unspecified Notes Design meets Code minimum (2xU180) Total load deflection criteria for cantilever spans due to roof loads. Design meets Code minimum (U240) Total load deflection criteria for non cantilever spans. Design meets Code minimum (2xU240) Live load deflection criteria. Design meets arbitrary (1') Maximum load deflection criteria. Composite El value based on 23/32' thick sheathing glued and nailed to joist. Joist1J01 Monday February 13 2006 14 49 12 -00 -00 Snow Wind Roof Live 115% 133% 125% OCS 16' 375 plf 16' Disclosure Completeness and accuracy of input must be verified by anyone who would rely on output as evidence of suitability for particular application. Output here based on building code accepted design properties and analysis methods. Installation of BOISE engineered wood products must be in accordance with current Installation Guide and applicable building codes. To obtain Installation Guide or ask questions, please call (800)232 -0788 before installation. BC CALL® BC FRAMER® AJSTM ALLJOIST® BC RIM BOARDTM BCI® BOISE GLULAMT" SIMPLE FRAMING SYSTEM® VERSA -LAM® VERSA -RIM PLUS® VERSA -RIM® VERSA- STRANDTM VERSA -STUD® are trademarks of Boise Wood Products, L.L.C. BOrISE BC CALC® 9.2 Design Report US Build 141 Job Name. Address. City State, Zip Customer Code reports. 02 -00-00 B1 3 -1/2' LL 398 lbs DL 1104 lbs SL 1427 lbs Load Summary Tap Description 1 Standard Load 2 Controls Summary Pos. Moment Neg Moment End Reaction Int. Reaction Cont. Shear Total Load Defl. Live Load Defl. Total Neg. Defl. Max Defl. Span Depth Load Type Unf Area Conc. Pt. ARSLAN 1118 W 7TH STREET PORT ANGELES, WA 98363 ARSLAN ESR -1336 Value 1416 ft-lbs -4089 ft-lbs 409 lbs 2907 lbs 2109 lbs 2x0219 (0.219 2x0344 (0 139 -0 129' 0.219' 15.2 Bearing Supports Dim. (L x W) B1 Beam 3 -1/2' x 4 B2 Beam 3 -1/2' x 4 B3 Wall /Plate 2 1/2' x 4 Cautions Design assumes Top and Bottom flanges to be restrained at cantilever Notes Design meets Code minimum (2x0180) Total load deflection criteria. Design meets Code minimum (2x0240) Live load deflection criteria. Design meets arbitrary (1') Maximum load deflection criteria. Composite El value based on 23/32' thick sheathing glued and nailed to joist. Page 1 of 1 Double 9 -1/2" BCI® 5000 -1 7 DF 3 spans I Left cantilever 1 0/12 slope 16' OCS I Repetitive I Glued nailed construction File Name: BC CALC Project Description: J02 Specifier Designer DONNA J PETERSEN PE Company 4 SEASONS ENGINEERING INC Misc: B2, 3 -1/2' LL 795 lbs DL 135 lbs Allowable 25.0% 72.3% 21 5% 60.2% 62.2% 82.2% 69 7% 25 8% 21 9% n/a Value 2929 lbs 930 lbs 475 lbs Ref. Left Left Joist1J02 Monday February 13 2006 14 48 X 11 11111_ .111111111111111111111111111111 t air 12 -00-00 (NI 12 -00 -00 Total Horizontal Product Length 26 -00 -00 Live Dead Snow Wind Roof Live 100% 90% 40 psf 17 psf 788 lbs 1181 lbs Start End 00 -00 -00 26 00 00 00 00 00 00 Duration Load Case 115% 13 115% 13 100% 14 115% 17 115% 17 13 13 13 13 Allow Allow Support Member 27 9% n/a 8.9% n/a n/a n/a Span Location 3 Internal 1 Right 3 Right 1 Right 1 Right 1 Cantilever 1 Cantilever 2 1 Cantilever 2 Material Versa -Lam 1 7 Versa -Lam 1 7 Unspecified 115% 133% 125% OCS 16' n/a B3, 2 1/2' LL 287 lbs DL 138 lbs SL 50 lbs Disclosure Completeness and accuracy of input must be verified by anyone who would rely on output as evidence of suitability for particular application. Output here based on building code accepted design properties and analysis methods. Installation of BOISE engineered wood products must be in accordance with current Installation Guide and applicable building codes. To obtain Installation Guide or ask questions, please call (800)232 -0788 before installation. BC CALC BC FRAMER® AJSTM ALLJOIST® BC RIM BOARDTM BCI® BOISE GLULAMT"' SIMPLE FRAMING SYSTEM® VERSA -LAM® VERSA -RIM PLUS® VERSA -RIM VERSA- STRANDTM VERSA -STUD® are trademarks of Boise Wood Products, L.L.0 1Z- Eagle Point Project: Job Client: Input Data Left Cantilever None Check for repetitive use? Yes Dead Load: 17 psf Allow LL Deflection: L/240 Eb. 1600000 psi Design Checks Max. Value Allowable of Allow Location Reactions and Bearing Program Version 8.2 12/17/2004 01 WINDOW HEADER 6' -Roof Beam 1968.75 3281 47 -i; 60 If 0' Main Span: 6'3' Tributary Width: 15' Live Load: 0 psf Allow TL Deflection. U180 F 180 psi 739.591 1242 60 V 3'1 1/2' oftiditionOv 1968.75 70.767 207 34 It 5'5 -3/4' 0' 1.5 6'3' 1.5 1968.75 Self- weight of member is not included. Member has an actual/allowable ratio in span 1 of 60 Se%. Design is governed by bending fb /Fb. Governing load combination is Dead +Snow Condition 1 w /Pattern Loads. Maximum hanger forces: 1968.75 lb (Left) and 1968.75 lb (Right). Page 1 11 04 16 02/13/06 Designed by Donna Petersen Checked by Right Cantilever None Slope: 0:12 Snow Load: 25 psf DOL. 1 150 Fb. 900 psi eift 0.0349 0.3125 11? 3'1 1/2' 0.0586 0.4167 14 V 3'1 1/2' Eagle Point Project: 1118W 7TH ST Job ARLAN Client: ARLAN Input Data '10404 Left Cantilever None Check for repetitive use? Yes Dead Load: 17 psf Allow LL Deflection: U240 Eb. 1800000 psi User Defined Loads 444041 Dead Snow Condition 1 Floor Live Design Checks Max. Value Allowable of Allow Location Reactions and Bearing "4000 0' 9'6' 02 GARAGE HEADER 9'-Roof Beam 6058.62 6120.03 991f 0' Program Version 8.2 12/17/2004 *pit_ Main Span: 9'6' Tributary Width: 0' Live Load: 0 psf Allow TL Deflection: L/180 F 240 psi sds Uniform Uniform Uniform 3.013 3.013 4v 2302.28 2760 83 le o 0' 6058.62 6058.62 Self-weight of member is not included. Member has an actual/allowable ratio in span 1 of 83 Design is governed by bending fb/Fb. Governing load combination is Dead+Floor Live+Snow Condition 1 Maximum hanger forces: 6058.62 lb (Left) and 6058.62 lb (Right). 6. 1,) V?..;,40 191.325 276 69 10' 10• 10' Page 1 11 17 38 02/13/06 Designed by Donna Petersen Checked by Right Cantilever None Slope: 0:12 Snow Load: 25 psf DOL. 1 150 Fb. 2400 psi 511 437.5 327 1.44011 -0.173 0.475 35t LPtit -0.2886 0.6333 45 Eagle Point Project: 1118 W 7TH ST Job ARLAN Client: ARLAN Input Data aV,0i71 t p a tt Left Cantilever None Check for repetitive use? Yes Dead Load: 17 psf Allow. LL Deflection: U360 Eb. 1800000 psi Design Checks 03 GARAGE FLOOR BEAM -Floor Beam tG 141 di Max. Value 11115 Allowable 11227.6 of Allow Location Reactions and Bearing 99 It 13' 0' 13' 26' Program Version 8.2 12/17/2004 .aittaftbed*aMO Main Span: 13' Main Span: 13' Tributary Width: 12' Live Load: 40 psf Allow TL Deflection: U240 (3 in Maximum) F 240 psi 1.5 3.37 1.5 1409.71 1813.98 78 if 13' tion>= N ctr 3724.5 11115 3724.5 Self- weight of member is not included. Member has an actuaVallowable ratio in span 1 of 78 I Design is governed by bending fb /Fb. Governing load combination is Dead +Floor Live w /Pattern Loads. Maximum hanger forces: 3724.5 lb (Left) and 3724.5 lb (Right). 119.078 240 50 it 12' Page 1 11:26:21 02/13/06 Designed by Donna Petersen Checked by Right Cantilever None Slope: 0 Snow Load: 0 DOL. 1.000 Fb. 2400 psi 0.1631 0.4333 37 b 5'11- 27/32' 91 0.2037 0.65 31? 5'11- 27/32' Eagle Point Project: 1118 W 7TH ST Job ARLAN Client: ARLAN Timber Desian 1 Option 1 Desian of Member 1 4x6 Design Data Design of Member 1 4x6 Material type is No. 2 Douglas Fir -Larch Dimensional Check for repetitive use? No Top flange bracing is Braced At Supports Moist use? No Bottom flange bracing is Braced At Supports Iy 19 7 in^4 Sr 11.2 in ^3 Snow Cd 1 15 I This is not a spaced column 1,= 48.5 in ^4 Sx 17.6 inA3 Shear CH 1 Side loaded? No Overstress factor 1 Allowable Floor live load deflection L/360 Allowable Floor total load deflection L/240 (3 in Maximum) Member weight used in analysis 0 plf Critical Design Checks Span 1 Value Allowable of Allow Location Span I Span 1 Critical Axial Bending X Bending Y Reaction psi psi psi lb 0 577 403 328147 687.607 0 0' Program Version 8.2 12/17/2004 04 Post Simple Column K 1 Lx 7' Ky =1 L 7 Area 19.25 in ^2 0 0 1046.96 1053 84 0' 0. 0' 0' 0' Shear psi Page 2 11:29 02/13/06 Designed by Donna Petersen Checked by Eb 1.6e+06 psi Eb 1.6e +06 psi G assumed as .06E Fb. 900 psi F,. 575 psi F. 1350 psi F 625 psi F 180 psi Actual density 35 pcf LL Deft. in 0 0 162 0.2333 0 b 0 t 5 -1/2' 0' TL Defl. in L/d I LA Fce I FCE y I FbE I KCE I c Limit psi psi psi Span 1 I 50 I 15.27 I 24 I 2057.82 I 833.333 I 10121.9 I 0.3 I 0.8 I Member has an actual/allowable ratio in span 1 of 84 1 Design is governed by axial fa/Fa. Governing load combination is Dead. Axial capacity of member is 13224.8 lb Locations of maximum stress, moment, etc. are measured from the left end of the member Bearing across full width of beam is required. Structural adequacy of supporting members must be confirmed. Bearing lengths required may be limited by bearing stress on supporting members. A negative reaction indicates that the beam must be fastened to the support to resist uplift. See manufacturer's literature for side loaded connection requirements. Cantilever deflection allowables are based on twice the span length. 0 0.35 0 s 0' CD I C, I C,, I Cy I Cr., I Cr I C I CPI I CPr I CH I CT 0.900 I 1.000 I 0.994 I 1.000 I 1.000 I 1.000 I 1.000 I 0.816 I 0.514 I 1.000 1.000 C,, I CFb I CR, I CFc I CMb I CMt I CM, I CMU I CMc I CME I Rb 1.000 I 1.300 I 1.300 11 100 I 1.000 I 1.000 I 1.000 I 1.000 I 1.000 I 1.000 I 8.33 psi 1336.5 Eagle Point Project: 1118 W 7TH ST Job: ARLAN Client: ARLAN Input Data Span 1 Overall Length Notes. Lengths are to center line of bearing. Elevation Angle is 90 deg. Bottom is considered to be pinned. User Defined Loads Load Case Load Type Description: Column Load Dead Concentrated Notes. Positive loads act down. Distances are measured along length of member Live loads are patterned to 100 Weight of members is not included in the calculations. Summary of Member Forces Load Combinations Span Axial Shear Shear Bending Bending Torsion Deflection Deflection Major Axis Minor Axis Major Axis Minor Axis Major Axis Minor Axis lb lb lb ft -lb ft -lb ft -lb in in Reactions Support 2 Span 11115 0 04 Post Simple Column Page 1 11:2931 02/13/06 Designed by Donna Petersen Checked by Horizontal Vertical Actual Axial Axial Span Span Length Unbraced Unbraced Length Length Length X Length Y ft ft ft ft ft 0' 7' 7' 7' 7' 0, 7' 7' Component Axial Distance(s) to Load Load at Load at Offset Offset Start Length Start End X 1' ft ft lb lb ft ft 7' 11115 0' 0' Load Horizontal Horizontal Vertical Moment Moment Comb. Major Axis Minor Axis Major Axis Minor Axis lb lb lb ft -lb ft -lb Dead 0.0 0.0 11115.0 0.0 0 0 Dead 0.0 0.0 0.0 0.0 0 0