Loading...
HomeMy WebLinkAbout802 C St Technical - BuildingTECHNICAL Permit# to -I"zl2 Address Project description AAA_ A Coo k v) a.YeA. S Date the permit was finaled 5 -13 -II Number of technical pages $3 v rsY Operations Service Manual FOODSERVICE EQUIPMENT Model: FSH-2A-99 F113 Giles Enterprises. Inc. An 1809001 Registered Company 2750 Gunter Park Drive West Montgomery AL 36109 USA Fax. (334) 272-3561 Internet: www.gilesentoom Service Hotline (Toll Free): 1-800-554-4537 (USA Canada Only) Form No. 60200 (Release date. 07/98)(Revision Date: 01/28/09)(Rev FSH-2, FSH-2A-99, FSH-2A-99W 11183 �!J LIMITED WARRANTY Subject to the terms and conditions of this Limited Warranty as herein stated, all Giles Enterprises Inc Foodservice Equipment and parts purchased new from an authorized Giles Enterprises, Inc representative are warranted as to defects in material or workmanship for a period of 12 months from the date of installation, provided, however that with regard to labor costs in connection with this warranty see below AU installations must be made by a qualified installing agency in accor- dance with all applicable codes and/or regulations in the jurisdiction in which installed. Limited war ranty coverage is extended to the original owner only and is void if the unit is resold During the Limited Warranty period, Giles Enterprises, Inc will replace or recondition, at its factory any part or parts of this unit which Giles Enterprises. Inc. inspectors judge defective, provided the unit has been subjected to normal usage, properly installed, operated and serviced. This Limited Warranty does not cover cosmetic damage, and damage due to acts of God, accident, misuse alter- ation, negligence abuse of the Giles Foodservice Equipment or the use of unorthodox repair meth- ods All parts replaced under this Limited Warranty carry only the unexpired term of this Limited Warranty Limited Warranty service may be furnished only by an authorized Giles Enterprises, Inc representative. If Limited Warranty service is requested Giles Enterprises Inc. will send factory authorized serv- ice representatives to repair recondition, replace or inspect units of its manufacture with such labor being rendered without cost to owner for ninety (90) days from the date of installation. Otherwise service, including labor and transportation charges or other expenses, in connection with the removal or installation of any part or parts supplied under this Limited Warranty are specified on the original sales contract between the purchaser and the authorized Giles Enterprises, Inc. represen- tative Giles Enterprises, Inc. reserves the right to change or improve its equipment and parts in any way without obligation to alter such equipment or parts previously manufactured. Giles Enterprises, Inc makes no further warranties, express or implied including implied warranties of merchantability or fitness for a particular purpose, and has no other obligation or liability not specifically stated herein Repair or replacement as provided under this Limited Warranty is the exclusive remedy Giles Enterprises, inc. shall not be liable for any incidental or consequential damages for breach of any express or implied warranty on this product, except to the extent prohibited by applicable law Any implied warranty of merchantability or fitness for a particular purpose on this product is limited in duration to the duration of this Limited Warranty Used Giles Enterprises Inc Foodservice Equipment or parts or Giles Enterprises, Inc. Foodservice Equipment or parts not purchased from an authorized Giles Enterprises, Inc. representative, carry no warranties, express or implied. Table Of Contents Safety Safety Overview Specific Safety Precautions 1 1 -01 1 -02. 1 -03 1 -03. 1 -03 01. 1 -03 02 1 -03 03 1 -03.04 1 -03 04 1 -03 06 Introduction Construction Standard Features Optional Feature Specifications Overall Dimensions Overall Dimensions Overall Dimensions Overall Dimensions Regulatory Listings Unit Weights 3 Overview 3 -01. Filter Area 3 -02 Control Panel 3 -03 Accessories (Included) for FSH -2 for FSH-2A for FSH -2A -99 for FSH- 2A -99W 2 Installation 2 -01. Location 2 -02 Unpacking 2 -03 Electrical Requirements 2 -03 01 Electrical Connections (Overview) 2 -03 02 Hood Power Connection 2 -03 03 Hood and Appliance interlock Connection 2 -03 04 Fire Alarm Connection 2 -04 Fryer and Oven Limitations and clearances 2 -04 01 Fryer Limitations under FSH -2, FSH -2A, FSH -2A -99 2 -04 02 Oven Limitations under FSH- 2A -99W 2 -04 03 Fryer Clearances for FSH -2 2 -04 04 Fryer Clearances for FSH -2A 2 -04 05 Fryer Clearances for FSH -2A -99 2 -04 06 Oven Clearances for FSH- 2A -99W 2 -05 Fire Suppression System 2- 05.01. Fusible Links and Gas Cartridge Location 2 -05 02 Fire Exinguishing Nozzles and Tank Location 2 -05 03 Manual Pull Diagram 2 -06 Restraining Device Model: FSH -2, FSH- 2A -99, FSH- 2A -99W 1 1 1 1 2 2 3 4 5 6 6 7 7 8 8 9 9 10 11 11 11 12 13 14 15 16 17 17 18 19 20 21 22 24 26 iii Model: FSH-2, FSH- 2A -99, Table Of Contents FSH- 2A -99W 4 Operation 4-01. Hood Operation 4 -02 Hood Filters and Filter Maintenance 4-02 01 Hood Filter Table 4-02 02 Baffle Filter Removal 4 -02 03 Baffle Filter Installation 4-02 04 Baffle Filter Missing 4-02 05 Baffle Filter Cleaning Procedure 4-02 06 EAC Filter Removal 4-02 07 EAC Filter Installation 4-02 08 EAC Filter Status. 4-02 09 EAC Fitler Cleaning 4-02 10 Charcoal Filter Removal 4-02 11. Charcoal Filter installation 4 -02 12 Charcoal Filter Missing 4-02 13 Charcoal Replacement Procedure 4-02 14 Ultra Violet Lamp Removal 4 -02 15. Ultra Violet Lamp Installation 4-02 16. Ultra Violet Lamp Cleaning 4-03 Maintenance 4 -03 01 Monthly Interlock Check 4-03 02 Quarterly Hood Cleaning 4-03 03 Semi Annual Fire Suppression System Servicing. 4-03 04 Annual Fire Suppression System Servicing 4-03 05 Twelve Year Suppression System Servicing 4-03 06 Maintenance and Service Log 5 Hood Cleaning 43 5 -01. Cleaning 43 6. Troubleshooting 45 6-01. Troubleshooting Procedures 45 7 Parts List 47 7 -01. Parts Ordering and Service Information 47 7 -02 Ventless Hood -Front 48 7 -03 Ventless Hood -Rear 50 8. Wiring Diagrams 53 8 -01. Wiring Diagram FSH -2, FSH -2A, FSH- 2A -99W 208 240/60/1 54 8-02 Wiring Diagram FSH -2, FSH -2A, FSH -2A 99W 208 240/60/1 w /lLS 56 8 -03 Wiring Diagram FSH -2 FSH -2A, FSH -2A -99W 208 240/60/1 wJUV 58 8-04 Wiring Diagram FSH -2, FSH -2A, FSH -2A -99W 208 240/60/1 w/lLS UV 60 8 -05 Wiring Diagram FSH -2A -99 ONLY 208 240/60/1 62 8-06 Wiring Diagram FSH -2A -99 ONLY 208 240/60/1 w /ILS 64 iv 29 29 29 29 30 31 32 32 32 33 33 34 35 35 36 36 37 37 38 39 40 40 41 41 41 42 s. Table Of Contents Wiring Diagrams Continued 8 -07 Wiring Diagram FSH -2A -99 ONLY 208 240160/1 w /UV 8-08 Wiring Diagram FSH -2A -99 ONLY 208 240/60/1 w /iLS UV 8 -09 Wiring Diagram FSH -2 FSH -2A, FSH -2A 99, FSH- 2A -99W 208 240/60/1 Model: FSH -2, FSH- 2A -99, FSH- 2A -99W 66 68 70 v Safety Safety Overview The instructions contained in this manual have been prepared to aid you in learning the proper procedures for installing and servicing your new unit. Throughout this manual, safety precautions are identified through the use of the safety alert symbol and three signal words DANGER,WARNING, and CAUTION All safety alert information precedes the step(s) to which they apply. Suggested, recommended, or other noteworthy information is identified through the use of NOTES. Additionally certain words are used to indicate a specific meaning or to add emphasis The following words are used as indicated throughout the manual. Shall: understood to be mandatory Should: understood to be advisory May understood to be permissive W ill: indicates a future event/condition to occur A or Used in conjunction with signal words (DANGER,WARNING, or CAUTION) to alert you of potential per sonal injury hazards, immediately preceding precautionary measures that pertain to subsequent steps) Obey all safety messages that follow this symbol to avoid possible injury or death. Failure to adhere to safety precautions identified by the safety alert symbol may also void the warranty. Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury Also used to alert against unsafe practices Model: FSH -2, FSH- 2A -99, FSH- 2A -99W •When used without the safety alert symbol, CAUTION indicates a potentially hazardous situation which, if not avoided, may result in equipment/property damage, and void the warranty NOTE: Identifies suggested, recommended, or other noteworthy information. VII Model: FSH -2, FSH- 2A -99, Safety Specific Safety Precautions For your safety please observe the following precautions when operating or servicing your Giles equip- ment. Read the following important safety information to avoid personal injury and /or damage to the equipment. Turn off the unit and unplug the power cord before cleaning or performing maintenance DO NOT hose down the unit interior or exterior with water Failure to comply with these DANGER notices will result in death or serious injury, equipment/property damage, and void the warranty viii Consult a qualified electrician to ensure that: all electncal specifications and codes are met. circuit breakers and wiring are of sufficient rating and gauge FSH- 2A -99W The unit must be properly grounded and all electrical specifications must be met during installation. Improper installation, adjustment, alteration, service or maintenance could result in death or serious injury, equip ment/property damage, and void the warranty DO NOT use or store gasoline or other flammable liquids or vapors in the vicinity of this or any other appliance! Failure to comply with WARNING notices could result death or serious injury and equipment/property damage and void the warranty Internal ultraviolet radiation source Keep protective bamer in place Replace all removable parts after servicing. An interlock is provided to reduce exposer to excessive ultraviolet radiation. DO NOT defeat the purpose of the interlock. x Model: FSH -2, FSH- 2A -99, Safety FSH- 2A -99W NOTE. An HVAC specialist may be required for installations to confirm proper air exchange and the heat load capabilities of the on site AC system Exhaust ventilation is recommended for areas in which recirculating hoods are used We recommend 50 CFM per lineal ft. of hood. •This amount could vary based on local codes and the site specific installation requirements Notes: Safety The unit must be adequately and properly grounded. Improper grounding may result in electrical shock. Always refer to your local electrical code to ensure proper grounding of this or any other electrical equip- ment. Always consult with an electrician or other qualified service person to ensure breakers and wiring are of sufficient rating and gauge for the equipment being operated. Ensure the unit is positioned in a secure, safe location. Consult an electrician to ensure all electrical specifications have been met and the unit rs properly grounded. The wiring diagrams contained in this manual should aid your electncian in the installation of your unit. The electronic components of the Control Panel are impact sensitive Exercise care around the Control Panel to maintain proper operation. During cleaning of the unit DO NOT steam clean. DO NOT use products containing chlorine DO NOT use abrasive products, steel wool or scouring pads DO NOT modify, alter or add attachments to this equipment) Failure to comply with these CAUTION notices may result in equipment/property damage and void the warranty The unit must remain in the upright (vertical) position. Exercise care when removing the wooden crate from around the unit. DO NOT operate the unit unless you fully understand the components and their intended function (see Section 3) Model: FSH -2, FSH- 2A -99, FSH- 2A -99W NOTE. If the crate is damaged upon receipt, immediately inspect the unit and notify the camer of any damage to the unit. To aid the electrician, an electncal winng diagram is contained in this manual. Refer to the wiring diagram during installation or servicing Comply with all appropriate state and/or local heath regulations regarding the cleaning and sanitation of equip- ment. ix Introduction Congratulations on the purchase of your new Giles Free Standing Ventless Hood, Model FSH -2 FSH -2A, FSH -2A -99 or FSH -2A -99W manufactured by Giles Enterprises, 'Inc. Montgomery Alabama (USA) here- after referred to as 'Giles' The Free Standing Ventless Hood is a product of extensive research and test- ing. Every unit is thoroughly inspected and tested prior to shipment. Proper care and maintenance will ensure years of trouble -free service The Giles Ventless Hood System is used in conjunction with various listed cooking appliances to accom- plish removal of grease vapors and objectionable odors which may be generated during cooking The hood system performs this function through the use of what is commonly referred to as an electronic air clean- er (EAC) Electronic air cleaners use an electrical charge to remove contaminants from the air as they pass through the EAC. To help protect your investment in this equipment, we recommend taking a few moments to familiarize yourself with the installation, cleaning and maintenance procedures contained in this manual Read these instructions before installation and use Adherence to these recommended procedures minimizes the potential for costly down-time' and equipment repairs. Please retain this manual for future reference All of the unit's exterior parts are constructed of stainless steel Three Staae Filtration -uses three different filters to remove particulate matter from the air Ultimate Ventless: Model: FSH -2, FSH- 2A -99, FSH- 2A -99W Extinauishinc_System -built into the hood to extinguish an accidental fire from the Fryer installed underneath the hood Ultra Violet light in conjunction with Giles patented air filtration system improves emission cleaning and odor control as well as keeping the unit free from grease build up Interlockina Start System (ILS) Interlocking Start System (ILS) -This system will cause the Hood and the Appliance below the Hood to shut down when the hood filters need to be cleaned or are not properly installed. ILS is required by some cities and /or states Please check with your local code officials to see if this system is required. 1 Model: FSH -2, FSH-2A-99, FSH- 2A -99W 2 Fire Detection Bracket fire Norm Junction 0001 U FRONT INCHES [MILLIMETERS] a 24 3/16 [613.92]. L+-+1 o m A 31 1/2 [800.44]-... 30 1/4 [767.66] FSH -2 (A) FSH -2 (B) FSH -2 (C) FSH-2 (D) FSH -2 (E) FSH -2 (F) FSH-2 (G) FSH-2 (H) RIGHT SIDE 1 20-1 /8 I 18-5/8 I I 16-1/8 1 15-5/8 I 15-1/8 I I 14-1/8 I I 10-1/8 I 0 N N a m 609 6 511.2 473.1 409 6 396 9 384 2 358.8 2572 Air Outlet Fire Domper)1 I -29 11/16 [75352] BACK Introduction o� "Coclxe' Sight Hole Remote Fire U Pull Connection Introduction Fire TialaQD'QT Detection Bracket a i. 0 n n 15 1/4 [387.84] m a Fire Alarm .rancho Box 7 X —I FRONT INCHES [MILLIMETERS] a RECOMMENDED TO MONS lIut TO MUM m 24 3/16 [613.92] Air Outlet 40 1/16 [1016.88] m Fre Dumper) 1 li r ha 1 0 i� 1 or 0 Fire Suppremion Q" Note 0 37 5/8 [954.98] 38 3/4 [983.56] RIGHT SIDE Interlock De —en tootle Service arenas= DOCKING ,OPENING WIDTH MODEL (LETTER DESIGNATION INCHES M FOR OPENING) FSH -2A (A) 24 609 6 FSH -2A (B) 20-1/8 511.2 FSH -2A (C) 18-5/8 1 473 1 FSH -2A (D) 16-1/8 409 6 FSH -2A (E) 15-5/8 396.9 FSH -2A (F) 15-1/8 384.2 FSH -2A (G) 14-1/8 1 358.8 FSH -2A (H) 1 10-1/8 1 257.2 Model: FSH -2, FSH- 2A -99, FSH- 2A -99W U 29 11/16 [753.52] BACK Remote Fire 3 Model: FSH -2, FSH- 2A -99, FSH- 2A -99W 4 Fire Detection Bracket Pk Flow x _1 I FRONT INCHES [MILLIMETERS] Air discharges to the Left and Right Fee Alarm Junction Ben 40 1/16 [1016.88] 1 1401. 10 CEILING 7 13/16 [198.00] 15 1/4 [387.84] A 37 5/8 [9541 38 3/4 [983.56] man SInF 6ntertada Tie-In Leads Service Entrance DO CKING OPENING WIDTH r MODEL (LETTER'DESIGNATION F OR OPENING) INCHES MILLIMETERS FSH-2 (A) 24 609 6 FSH -2 (B) 20-1/8 5112 FSH -2 (C) j 18-5/8 473 1 FSH-2 (D) 16-1/8 409 6 FSH -2 (E) J 15-5/8 396.9 FSH -2 (F) 15-1/8 J 384.2 FSH-2 (G) 14118 358.8 FSH -2 (H) f 10-1/8 I 2572 Introduction 24 3/16 [613.92] 4 0 0 sght Cr. Hole 29 11/16 [753.52] HACK Remote Fire been Introduction Fire Detection Bracket Air discharges to the Lett and Right Fre Alarm Junction Box r 40 1/16 [1016.88] 1 FRONT INCHES [MILLIMETERS] AAN. TO CERJNG 15 1 '4 [387.84] 35 1/16 [890.30] 36 3/16 [918.87] 1--- 24 3/16 [613.92] N m Model: FSH -2, FSH- 2A -99, FSH- 2A -99W Fre Suppression "Cocked" Sight co Interlock O Hole Tie —In Leads Service Remote Fre Entrance Suppression -c Pull Connection v RIGHT SIDE BACK 5 Model: FSH -2, FSH- 2A -99, FSH- 2A -99W UL (US and Canada) NSF CE 6 FSH -2 FSH-2A FSH -2A -99 FSH -2A -99W Introduction 462 146 327 148 609 277 454 206 535 243 380 173 635 289 480 218 J Installation This section provides a summary of the procedures necessary for proper installation of your unit. To help pre- vent personal injury or equipment damage, please ensure the following steps are taken. NOTE. *The decibel level of the hood when operating is approximately 65 dB's DO NOT MODIFY, ALTER OR ADD ATTACHMENTS TO THIS EQUIPMENT Model: FSH -2, FSH- 2A -99, FSH- 2A -99W 1. Before unpacking the unit and assembling the unit, using the dimensions and clearances shown in Section 2 -04 03. and 2-04 06 determine the location of the unit. 2 Keep the unit and the surrounding area free and clear from combustible materials 3 Please provide adequate room for servicing and proper operation of the unit. Also provide adequate ventilation in the operating area where necessary 4 Before operating, make sure the unit is in a secure position and will not move NOTE: An HVAC specialist may be required for installations to confirm proper air exchange and the heat load capabilities of the on site AC system Exhaust ventilation is recommended for areas in which recirculating hoods are used We recommend 50 CFM per lineal ft. of hood 'This amount could vary based on focal codes and the site specific installation requirements 7 Model: FSH -2, FSH- 2A -99, FSH- 2A -99W CC. Installation Your unit may arrive enclosed by a wooden crate The Hood is secured to a wooden platform by means of high- tensile strength strapping NOTE. If the crate is damaged, immediately inspect the unit and notify the carrier of any damage to the unit. Exercise care when lifting or moving the unit. Exercise care when removing the wooden crate from around the unit. Failure to comply with these CAUTION notices may result in minor or moderate injury, equip ment/property damage, and void the warranty. 1. Carefully cut and remove the plastic shipping wrap and the strapping mentioned above 2 Use pliers to loosen wire hooks which secure the wooden crate around the unit. Remove the wooden crate 3 Carefully remove the unit from the shipping platform Your new FSH -2, FSH -2A, FSH -2A -99 or FSH 2A-99W is extremely heavy see Section 1 -03.04 for unit weights. Great care should be taken in lift- ing or moving the unit to prevent personal injury or equipment damage Consult a qualified electrician to ensure all electrical specifications have been met and that the unit is properly grounded The unit must be adequately and properly grounded. Improper grounding may result in electrical shock. Always refer to your local electrical code to ensure proper grounding of this or any other electrical equipment. Always consult with an electrician or other qualified service person to ensure breakers and wiring are of sufficient rating and gauge for the equipment being operated. Improper installation, adjustment, alteration, service or maintenance could result in death or serious injury equip ment/property damage, and void the warranty ood Electrical Requirements nit Voltage r Hz Phase 8 FSH -2 FSH -2A FSH -2A -99 FSH -2A -99W f 208 -240 208 -240 208 -240 208 -240 60 60 60 60 1 1 1 1 3 3 3 3 10 10 1 0 10 Installation Connect Hood Power 3 Make all appropiate connections. 4 Reinstall Service Entrance Box Cover Fire Alarm Tie-In Box Interlock Tie-In Box Service Entrance Box Connection to Appliance s uPPLy P owER 140 400 Ec 10a Model: FSH -2, FSH- 2A -99, FSH- 2A -99W 1 Install appropriate Circuit Breakers in Hood Supply Power Box (Main Breaker Box) See Section 2 -03 for required Circuit Breakers 2 Remove Cover on Service Entrance Box and run appropriate size conduit and wire from the Service Entrance Box to the Hood Supply Power box (Main Breaker Box) Allow enough conduit and wire so the unit can be accessed for cleaning and servicing 9 Model: FSH -2, FSH- 2A -99, FSH- 2A -99W This connection will cause the Appliance installed below the Hood to shut down if any of the following occurs Any Filter becomes excessively dirty not allowing proper air flow through the Hood. Any Filter is missing or not installed correctly The Fire Extinguisher System is activated. Interlock Hood to Appliance: 1 Remove Cover on Interlock Tie-In Box and run appropriate size conduit and wire from the Interlock Tie-In Box to a Hood and Appliance Connection Box (Supplied by Customer) Allow enough conduit and wire so the Hood can be accessed for cleaning and servicing 2 Make appropiate connections See Diagram below 3 Reinstall Interlock Tie-In Box Cover 10 /PRANCE (SUPPLIED BY cuSTOMER) BTEBLOOC RELAY IN HOOD comm. POYIFR r CONTROL POER —HOOD SUPPLY POWER (SUPPUED BY CUSTOMER) I L___1 1 I I I I ill- -r r "-1L '+—iii- --F -----I---i--- -1 —4--e --4u L —J L CONTACTOR LOAD CENTER ammo BREAKER (SUPPLIED BY CUSTOMER) (S PLIED BY OSIOMER) -HOOD MID APPLIANCE cEDYP ED BY CUSTOMER) MPLYMCE SUPPLY POER— (SPPiBD BY Installation NOTE: If not using the ILS option, the Hood will continue to run and the Appliance will turn off when: Any Filter becomes excessively dirty, not allowing proper air flow through the Hood. Any Filter is missing or not installed correctly. The Fire Extinguisher System is activated. If using the 1LS option, the Hood and Appliance will turn off when: Any Filter becomes excessively dirty, not allowing proper air flow through the Hood. Any Fitter is missing or not installed correctly. The Fire Extinguisher System is activated. Installation This connection will send a signal the Facility Fire Alarm System that the Hood Fire Extinguisher System has been activated. Fire Alarm Connection: 1 Remove Cover on Fire Alarm Tie-In Box and run appropriate size conduit and wire from the Box to the Facility Fire Alarm System Allow enough conduit and wire so the Hood can be accessed for cleaning and servicing 2 Make appropiate connections 3 Reinstall Fire Alarm Tie-In Box Cover This section describes various limitations to the fryers and the oven that can be placed underneath the hoods. Please note only Electric Fryers and Ovens that do not exceed the following limitations and follow- ing clearances are approved to be placed under these hoods. Gas Fryers, Gas Ovens, or any other type of appliances are not approved. These Hoods are design for Electric Fryers Only!!! DO NOT USE ANY GAS APPLIANCES UNDER THE FSH 2, FSH -2A, FSH- 2A -99!!! FSH -2 FSH -2A FSH -2A -99 20 (Fryers only) 20 (Fryers only) 20 (Fryers only) Model: FSH -2, FSH- 2A -99, FSH- 2A -99W 110 380 Sq. In. 110 380 Sq In. 110 380 Sq In 11 Model: FSH -2. FSH-2A-99, FSH- 2A -99W 12 This Hood is design for Electric Ovens Only!!! DO NOT USE ANY GAS APPUANCES UNDER THE FSH- 2A- 99W!!! FSH- 2A -99W 8 (Ovens only) 450F Installation ax kW Input Maio Oven Temperature Installation x Ith —29 11/16 [753.521 FRONT INCHES [MILLIMETERS] FSH -2 (A) FSH -2 (B) FSH -2 (C) FSH-2 (D) FSH -2 (E) FSH -2 (F) FSH -2 (G) FSH -2 (H) Fusible Link 7 11/16 [195.72] 3 MIN. [76.20] L 'RECOMMENDED TO CEILING MIN. TO CEILING 24 20-1/8 I 18-5/8 I 16-1/8 I 15-5/8 I 15-1/8 14-1 /8 10-1/8 1 i. -6 3/4 [171.62] Fry Vat RIGHT SIGH DO CKING OPENING WIDTH MODEL (LETTER DESIGNATIO FOR OPENING) INCHE Model: FSH -2, FSH- 2A -99, FSH- 2A -99W 609 6 511 2 473.1 409 6 396.9 384 2 358.8 257.2 Fryer Only O co 0 O N m 13 Model: FSH -2, FSH- 2A -99, FSH- 2A -99W er Clearances for FSH-2A 14 Tluzia q FRONT INCHES [MILLIMETERS] 0 tJ RECOMMENDED TO CEILING MN. TO CEILING 40 1/16 [1016.88] Fusible Link 2 1/2 [63.50] ai 7 11/16 [195.84] m N 3 NW. [76.20] RIGHT SIDE FSH -2A (A) 24 609 6 FSH -2A (B) 20-1/8 511 2 FSH -2A (C) 18-5/8 I 473.1 FSH -2A (D) 16-1/8 i 409 6 FSH -2A (E) 15-5/8 1 396 9 FSH -2A (F) 15-1/8 I 384 2 FSH -2A (G) 14-1/8 358.8 FSH -2A (H) I 10-1/8 2572 0 co 0 0 N 7 3/4 [197.60] 15 1/4 [387.84] Fryer Only DOCKING OPENING WIDTH X" MODEL'(LETTER'DESIGNATION INCHES MILLIMETERS FOR OPENING) Installation Installation Fire Detection Bracket 2 1/2 [63.50] Air Flow SElit FRONT INCHES (MILLIMETERS) Air discharges to the Left and Right x ir Fire Alarm Junction Box Fusible Link 7 13/16 [198.00] 7 11/16 [195.84] 3 [76.20] 40 1/16 [1016.88] __MIN. TO CEILING FSH -2A -99 (A) 24 609 6 FSH-2A-99 (B) 20-1/8 511.2 FSH -2A -99 (C) 18-5/8 1 473 1 FSH -2A -99 (D) 16-1/8 409.6 FSH -2A -99 (E) 15-5/8 E 396.9 FSH-2A-99 (F) 15-1/8 384.2 FSH -2A -99 (G) 14-1/8 358.8 FSH -2A -99 (H) I 10-1/8 2572 Model: FSH -2, FSH-2A-99, FSH- 2A -99W Fry Vat 38 3/4 [983.56] RIGHT SIDE DOCKING OPENING WIDTH MODEL (LETTER-DESIGNATION I �s FOR OPENING).... NCHES MI Fryer Only 15 Model. FSH -2, FSH- 2A -99, FSH- 2A -99W 2 1/2 [63.50] 16 Fire Detection Bracket Air discharges to the Left and Right Air Flow 30 [762.00] MAX. 32 [812.80] 37 3/16 [944.98] FRONT INCHES [MILLIMETERS] Fusible Link N 0) d' N N 0) 40 1/16 [1016.88] YIN. TO CELIAC 10 [253.72] MIN. 1 23 [583.68 35 1/16 [890.30] 36 3/16 [918.87] RIGHT SIDE L.: Installation to N n OVEN ONLY 0 In N 0) 0) Installation The fire suppression system used in your Giles Ventless Hood is an Ansul R -102 Restaurant Fire Suppression System (Standard UL 710B Listed) Final installation, charging and testing of the system must be performed by an authorized Ansul distributor in accordance with the system's listing. The fire suppression system is designed and UL-listed to provide fire protection for cooking appliances such as fryers It protects your units, automatically, 24 hours per day The system contains piping, nozzles (both appliance and plenum) and conduit for routing the fusible link cable through the hood. Fusible Link 285 Degree F Installed at Factory Fusible Link 165 Degree F Supplied Installed by Ansul See Appliance Fusible Link below Appliance Fusible Link: If less than 3 176 2] to cooking surface use Fusible Link 165 Degree F Supplied Installed by Ansul If more than or equal to 3 [76.2] to cooking surface use Fusible Link 135 Degree F Supplied Installed by Ansul INCHES [MILLIMETERS] Appliance Cooking Surface LT-20 R Cartridge Supplied Installed by Ansul Model: FSH -2, FSH- 2A -99, FSH- 2A -99W 17 Model FSH -2, FSH- 2A -99, FSH- 2A -99W ire.Exinguishing• Nozzles and Tank Location All nozzles have been factory installed in the proper operating position. DO NOT MOVE OR ADJUST 18 Plenum Nozzle Giles P/N 46426 Plenum Nozzle Giles P/N 46426 FSH -2 Appliance Nozzle Giles P/N 46426 FSH -2A Appliance Nozzle Giles P/N 40131 FSH -2 Appliance Nozzle Giles P/N 46426 FSH -2A Appliance Nozzle Giles P/N 40131 Tank, 1 -1/2 Gallon Giles P/N 39272 Installation Installation This Hood requires use of the Ansul R -102 Standard for a Manual Pull System The Manual Pull System must be mounted on a near -by wall and connected to the Hood. This Manual Pull System is used to activate the Fire Extinguisher System from a remote location. The Manual Pull System is supplied and installed by Ansul The following illustration is a typical Manual Pull installation Using this basic configuration the Hood may be moved from the wall for Cleaning and Servicing without removing the Manual Pull from the wall. 0 Model: FSH -2, FSH- 2A -99, FSH- 2A -99W 1/2 Conduit from Hood 90 Degree Pulley 90 Degree Pulley Ansul Manual Pull Assembly mounted on the wall 19 Model FSH -2, FSH- 2A -99, FSH- 2A -99W Any Fryer placed under this Hood must be secured so that the Fryer can not move from below the Hood. The following is an example of a restraining device that may be used. The appropiate restraining device will vary depending on the Fryer the restraining device is not supplied with the hood. 20 Syfrq }fgch..Al:uCtaYtsmtT Note: Be sure to maintain minumum and maxi- mum clearances (see Section 2 -04 02 or 2 -04 03 after the Restraining Device is installed. Installation Overview The following section provides a brief overview of the components, functions, and accessories of the Free. Standing Hood, Model FSH -2 FSH -2A, FSH -2A -99 and FSH -2A -99W. Please review this section carefully before proceeding any further UV Sight Window (optional) Appliance Centering Bracket Model: FSH -2, FSH- 2A -99, FSH- 2A -99W Filter Area Figure 3 -01 Control Panel Figure 3 -02 Fryer or Oven Area (Fryer or Oven not shown) 21 N N Overview *1 2 Hood Filter Cover Ultra Violet Lamp (optional) 3 Charcoal Fitter 4 EAC Filter 6 Grease Drip Cup 7 Grease Dnp Cup Safety Pin 8 Exhaust Stack 9 Appliance Fusible Link -Not Shown Model: FSH -2, FSH- 2A -99, FSH- 2A -99W Used to access the Electronic Air Cleaner (EAC) and Charcoal Filters This cover must be in place and latched for the unit to oper- ate. Ultra Violet Panel has sight windows. Improves emission cleaning and odor control as well as keeping the unit free from grease build -up, improving fire safety and lead- ing to less maintenance. This lamp should be cleaned monthly and replaced annually. DO NOT touch Lamp with bare hands This Filter helps to remove odors generated during cooking. This Filter should be replaced monthly NEVER attempt to clean a Charcoal Filter. Keep a spare filter on hand (Giles 30248) for quick change -out when needed! DO NOT remove the Charcoal Filter while the Hood or the Fryer is operating to prevent contact with electrical parts and avoid electrical shock. The EAC Filter is an electrical device which removes grease vapor and smoke generated by the fryer during cooking Power must be turned OFF to the Hood and Fryer before removing the EAC for cleaning. The EAC should be cleaned daily. DO NOT remove the EAC Fitter while the Hood or the Fryer is operating to prevent contact with electrical parts and avoid electrical shock. The Baffle Filter is the first stage of the grease extraction and air cleaning system found on these units. It is easily removed for daily 5 Baffle Filter cleaning. DO NOT remove the Baffle Fitter while the Hood or the Fryer is operating to prevent contact with electrical parts and avoid electrical shock. Used to hold excess grease from the hood. This cup should be cleaned daily or as needed. Used to hold the Grease Drip Cup in place and to prevent the cup from accidentally dropping Located on top of the unit. Allow the recommended clearance of 18" or a minimum clearance of 12° between the top of the Exhaust Stack and the ceiling. Used to detect a fire in the Fryer Vat. Be careful not to hit or bump this link. Doing so may inadvertently cause the Fire Extinguisher System to activate 23 a) s E a) 0 Overview 1 2 3 4 5 6 7 *8 Not Shown ON Indicator Light (EAC Status) WASH Indicator Light (EAC Status) CHECK Indicator Light (EAC Status) Hood Powered Indicator Light Fryer Powered Indicator Light Filter Missing Indicator Light Power Switch Push and Hold to Start Button Model: FSH -2, FSH- 2A -99, FSH- 2A -99W Used to indicate the Electronic Air Cleaner (EAC) Filter is on or powered Used to indicate the EAC has become excessively dirty Do not rely upon this light as a signal for routine cleaning of the EAC Failure to clean the EAC daily will significantly decrease the life of the charcoal filter Clean the EAC daily for best per formance Used to indcate the EAC Filter is no longer cleaning the air The EAC Filter must be cleaned or repaired. Used to indicate the Hood is powered and running. Used to indicate power is available to the Fryer under the hood. Used to indicate the Baffle Filter or Charcoal Filter is missing or not correctly in place Used to turn power on to the Hood and will allow the Fryer under the Hood to be turned on. (Used with ILS (Interlocking Start) units only) Used after the Power Switch is in the 'ON position, push and hold down PUSH AND HOLD TO START' Button for 5 seconds allow- ing the unit to start. This allows the Hood and the Fryer underneath to both shut down if the Hood Filters become excessively dirty This option is required by some cities. Please contact your local code officials to see if this is required in your city 25 Model: FSH -2, FSH- 2A -99, FSH- 2A -99W 26 Baffle Filter P/N 42300 EAC Filter P/N 20520 Charcoal Filter P/N 30248 Overview Used for removing smoke and contaminants from the air Used for removing smoke and contaminants from the air Used for removing odors from the arr Overview EAC Soak Tank P/N 39327 UV Lamp P/N 90226 Model: FSH -2, FSH- 2A -99, FSH- 2A -99W Used for cleaning EAC filter Used for emission control 27 Model FSH -2, FSH- 2A -99, FSH- 2A -99W Notes: 28 l Overview Operation This section describes the operation of and the filter maintenance for the Hood. This section describes how to start the Ventless Hood Make sure all the Filters and UV Light are in place and correctly installed before operating the unit. 1 Press the Power Switch to the ON A position, (if 1LS, then press and hold the Push and Hold to Start switch, for 5 seconds) the foil ing will occur illuminates indicating the EAC filter is cleaning the air. illuminates indicating the Hood is on and powered. illuminates indicating power is available to the Fryer underneath the Hood. sight window illuminates indicting UV is operating 2 The Fryer underneath the Hood may now be turned on and used. This section describes each Filter and It's maintenance required. Baffle Filter EAC Filter Charcoal Filter Ultra Violet Light Clean daily Clean daily Replace every 30 days, P/N 30248 Clean every 30 days Replace annually Section 4-02 06 Section 4-02 08 Section 4-02 12 Section 402 14 lam RI,. TT—. O ROSH TO STMT ON aFF -ILS only Section 4-02.07 Section 4-02,11 Never clean, only replace Section 4-02 15 Section 4-02.16 Model: FSH -2, FSH- 2A -99, FSH- 2A -99W Section 4-02 08 Section 4-02 09 Section 402 13 Section 4-02 15 29 Model: FSH-2, FSH-2A-99, FSH-2A-99W 30 Operation Operation affle Filter installation Model: FSH -2, FSH- 2A -99, FSH- 2A -99W Switch arm must be actuated by the Baffle Filter as shown 31 Model: FSH -2, FSH- 2A -99, FSH- 2A -99W If the Baffle Filter is missing or not in place correctly the Filter BEM Missing Light A will come on. See Section 7 -02.03 Baffle Filter e s Installation. e e o o e.7 0 The Baffle Filter should be cleaned daily Place the Baffle Filter in a sink and clean with a mild degreaser Dry thoroughly then reinstall in the unit. 32 Hood Filter Cover Operation Operation Hood Filter Cover EAC Air Flow Arrow locatated on the left or right of the EAC Handle and must point up The three indicator lights on the Control Panel display the status of the EAC Filter ON The EAC Filter is in place and pow- ered. el WASH The EAC Filter is becoming excessive- ly dirty and must be cleaned. If this light is on for more then 2 minutes an intermittent alarm will sound, and power to the Fryer underneath the Hood will be turned off. CHECK The EAC Filter is not operating, either the filter is not properly connected to the power source or it is damaged. If this light is on for more then 2 min- utes an intermittent alarm will sound, and power to the Fryer underneath the Hood will be turned off Filter must align with this pin Model: FSH -2, FSH- 2A -99, FSH- 2A -99W 1 0 R 1 O Wsrp STAN STMT ON E 0 E OFF 33 Model. FSH -2, FSH- 2A -99, FSH- 2A -99W Do not bend the fins or break the ionizer wires on the EAC as this will prevent the EAC from working properly and potentially void the warranty. 1 Mix 1/2 Gallon of a mild non-caustic biodegradable degreaser such as Simple Green or Clean Magic, with 6 5 gallons of water in the included Soak Tank NOTE. The mixed solution in the Soak Tank should last up to 30 days without being changed. 2 Holding the contact plate 12 on the EAC slowly lower the fil- ter into the Soak Tank. 3 After allowing the EAC to soak for 20 to 30 minutes, using the con- tact plate 13, lift the EAC up and down approximately 1 to 2 to help remove the grease residue 4 Slowly remove the EAC from the tank and rinse clean in a sink using hot water 5 Allow the EAC to air dry thoroughly 34 Fins Ionizer Wires (9) Required Operation N Do not dry the EAC either by running the hood to air dry or by running the appliance to heat dry. This could potentially damage the EAC causing improper operation and voiding the warranty. Operation Hood Filter Cover Hood Filter Cover Model: FSH -2, FSH- 2A -99, FSH- 2A -99W za`rcoal. Filter [nstallaton Switch must be actuated by the filter 35 Model FSH -2, FSH- 2A -99, FSH- 2A -99W If the Charcoal Filter is missing or not correctly in place the Filter Missing Light si will come on. See Section 4-02 11 Charcoal Filter Installation. Never attempt to clean the Charcoal Filter. Replace the Alter. The reuse of a Charcoal Filter can cause damage to the unit. 36 Replace the Charcoal Filter every 30 days Use Replacement Part No. 30248 00 o•g 0 e e O x000 O HO mins& ART ON P N Off Operation Operation 1. Place hood power switch off 2 Remove filter access cover 3 Disconnect UV Lamp wiring harness from power supply wiring harness 4 Loosen and remove thumb screws on each side of lamp guard. 5 Remove Lamp from holding brackets. 1. Install new UV Lamp in holding brackets 2 install lamp guard and tighten thumb screws. 3 Connect UV Lamp wiring harness to power supply wiring harness 4 Install all filters and access cover 5 Place hood power switch on Model: FSH -2, FSH- 2A -99, FSH- 2A -99W 37 Model: FSH -2, FSH- 2A -99, FSH- 2A -99W Do Not touch or handle UV Lamp with bare hands. This will greatly reduce the life of bulb. To be accomplished every 30 days Operation 1 Place hood power switch off 2 Remove filter access cover 3 Loosen and remove thumb screws at top of lamp guard. 4 Lightly spray a mild non caustic biodegradable degreaser such as Simple Green, onto the UV Light and wipe off residue with a dry lint free cloth 5. Re- install lamp guard. 38 Operation Model: FSH -2, FSH- 2A -99, FSH- 2A -99W This Section describes periodic maintenance for the Ventless Hood System Performance of these proce- dures will maintain the units efficiency over time. A Maintenance and Service Log is provided in this manual, see Section 4-03 06. Your Giles Ventless Hood System incorporates an Interlock System to ensure the unit is operated in a safe and effective manner Testing of the Interlock System should be conducted MONTHLY in the following man- ner Use the form located in Section 4-06.06 Maintenance and Service Log, place a check in the box that cor- responds to the test being performed. If a problem is found, call your service representative. Baffle Filter Check-With the Power Switch in the 'OFF position remove the grease baffle Place the Power Switch in the 'ON position. Check appliance power underneath the Hood, the appliance should not turn on. Turn the Power Switch to the 'OFF position and reinstall the grease baffle into the hood. 2 EAC Filter Check-With the Power Switch in the 'OFF" position remove the EAC Place the Power Switch in the 'ON position, wait two minutes Check appliance power underneath the Hood the appliance should not turn on. Reinstall the EAC 3 Charcoal Filter Check-With the Power Switch in the OFF position remove the Charcoal Filter Place the Power Switch in the ON position. Check appliance power underneath the Hood, the appliance should not turn on. Return the Power Switch to the OFF position. Reinstall the charcoal filter 4 Filter Clogged Check -Place the Power Switch in the 'ON position. Place a piece of cardboard over half the Grease Baffle Filter Check appliance power underneath the Hood, the appliance should not turn on. A steady tone buzzer will sound if the cardboard is not removed. Return Power Switch to the "OFF" position. Remove the cardboard. During cleaning of the unit DO NOT steam clean. DO NOT use products containing chlorine DO NOT use abrasive products, steel wool or scounng pads Remove power from the unit. Remove the Hood Filter Cover and all Filters from the hood. Using a mild degreaser clean the entire Hood Plenum and Blower Sections The hood must be cleaned every 3 months 39 Model: FSH -2, FSH- 2A -99, FSH- 2A -99W Operation Service of the Fire Suppression System is to be conducted by qualified fire equipment personnel As a minimum, field inspection of the Fire Suppression System is to be accomplished semi annually by qualified fire equipment service personnel. Such maintenance shall consist of the following (Consult the Giles Enterprises Design Installation, Recharge and Maintenance Manual for complete servicing guidelines). Place fire extinguishing system locking bar on fire system when servicing hood. 1. Remove charging cartridge, inspect gasket for cuts and elasticity coat gasket with extreme tempera- ture grease and reinstall. See Section 2- 06.01. Fusible Link and Gas Cartridge Locations 2 Remove tank, verify chemical is at proper level clean and coat 0 -ring with extreme temperature grease and reinstall See Section 2-06 02 Fire Extinguisher Nozzle and Tank Locations 3 Check all nozzles to insure they are free of cooking grease buildup. 4 Test the remote manual pull station for activation and wear 5. Install test link and cut to simulate automatic actuation 6 Clean and inspect fusible finks.See Section 2 -06 01 for Fusible Link and Gas Cartridge Locations 7 Inspect wire rope for wear at pulleys and detectors and replace if necessary 8 Record maintenance date and maintain in a permanent file Same as Semi Annual but all fusible links must be replaced with new fusible links. See Section 2- 06.01. Fusible Link and Gas Cartridge Locations. Do Not touch or handle UV Lamp with bare hands. This will greatly reduce the life of bulb. Replace Ultraviolet Lamp annually Same as Annual except for the following. 1. Replace R -102 fire suppression chemical 2 Hydrostatically test the tank and cartridge 3 Flow test the regulator 40 Operation NY NY \Y 11 2 1 1 2 112 314 31415 314 314 314 5 314 314 3 4 5 3 4 3 1 4 3 4 5 3 3 4 3 4 5 3 4 3 4 3 4 5 3 4 3 4 3 4 1 5 3 41 3 4 3 4 1 5 3 4 3 4 3 4 5 3 4 3 4 3 4 5 3 4 3 4 5 3 4 5 3 4 5 3 4 5 3 4 5 AB 1 403 1 'Baffle Filter Check 2 EAC Filter Check 4 Filter Clogged 5 Quarterly Cleaning 7 Fire Suppression System replace 'Fusible Links Inspection performed by a qualified fire equipment company 3 4 3 1 4 1 3 4 I5 3 4 1 3 4 3 4 1 5 3 4 3 4 3 4'1 5 3 4 '1 3 4 3 4 f 5 3 41 3 4 3 4 5 3 4 3 4 3 4 5 3 4 3 4 3 4 5 3 4 3 4 314 5 3 1 4 3 4 314 5 314 314 3 4 5 3 4 314 3 4 5 3 1 4 314 3 1 4 Model: FSH -2, FSH- 2A -99, FSH- 2A -99W 1 1 I I 6* 6* 6* 6* 7* 5 6* 17* 6 7 3 Charcoal Filter Check 6 Fire Suppression System 8 Replace UV Lamp (UV option Only) 41 Model. FSH -2, FSH- 2A -99, FSH- 2A -99W Notes: 42 Operation Hood Cleaning This section describes the cleaning of the hood. The hood must be cleaned every 3 months Interior Disconnect cower to the unit. Remove the Filter Cover and all Filters from the hood. Using a soft cloth, sponge or towel and a mild non caustic biodegradable degreaser clean the entire Hood Plenum area and Filter Channels Exterior remove power from the unit. Using a stainless steel cleaner clean all external stainless steel parts Filters To clean and replace Filters, see Section 4 02 01 Hood Filter Table UV Lamp To clean and replace UV Lamp, see Section 4 02 01 Hood Filter Table Model: FSH -2, FSH- 2A -99, FSH- 2A -99W 43 Model: FSH -2, FSH -2A, FSH- 2A -99, FSH- 2A -99W Notes: 44 Hood Cleaning Troubleshooting This section describes troubleshooting procedures for the FSH -2, FSH -2A, FSH- 2A -99, FSH- 2A -99W Refer to the wiring diagrams in Section 8 for more detailed analysis. Electrical troubleshooting procedures should be performed ONLY by qualified service personnel. Death or serious injury will result from contact with energized electrical components Failure to comply with these DANGER notices will result in death or serious injury equipment/property damage, and void the warranty Hood will not turn on Filter Missing Light on Check or Wash Light on a. (ILS only) Push and Hold button not held for 5 seconds lb. Power switch bad c. Improper supply voltage d. Hood cover not closed e. Not connected to power source f. Circuit breaker tripped a. Baffle filter is not installed a. EAC shorted b. EAC dirty c. High voltage power supply faulty. d. High voltage wires shorted. e. Bad contact plate Model: FSH -2, FSH- 2A -99, FSH- 2A -99W Hold down Push and Hold button until unit remains running b. Replace power switch c. Connect to proper voltage source a. d. Close hood cover e Connect to proper power source ff Reset Circuit breaker a. Install Baffle filter b. Charcoal filter is not installed b. Install charcoal filter a. Replace or repair EAC c. d. e. Clean EAC. Replace high voltage power supply Correct shorted condition. Replace contact plate 45 Model. FSH -2, FSH- 2A -99, FSH- 2A -99W Fryer or Oven will not turn on Hood Power Light on Filter Missing Light on Fryer or Oven will not turn on Hood Power Light on Buzzer emitting a continuous tone Fryer Powered light off Fryer or Oven will not turn on Hood Power Light on Buzzer emitting a pulsating tone Fryer Powered Light off la. b lc. a. l b. c. e. a b. c. ,d. e f 9. UV Lamp not illuminated a. b c. 46 d. Baffle Filter missing Baffle Filter not installed properly Charcoal Filter missing Charcoal Filter clogged Baffle Filter clogged Vacuum switch out of adjustment Kinked vacuum line Fan running slow EAC shorted EAC dirty EAC power supply faulty EAC wires shorted Bad contact plate EAC module faulty EAC ionizer wire broken or missing Bad Connection Lamp Blown Filters not installed correctly Access Pannel not installed e. Bad Ballast a. b 1c* a. lb c. Id. e. a b. c. d. e. f. 9 a. Reconnect b Replace Lamp c. Troubleshooting Install filters d. Install Access Panel e. Replace Ballast Install Baffle Filter Reinstall Baffle Filter Install Charcoal Filter Replace Charcoal Filter Clean Baffle Filter Adjust Vacuum switch only Remove vacuum line kinks Check voltage Repair EAC Clean EAC Replace EAC power supply Check voltage Replace contact plate Replace EAC module Replace ionizer wire Parts List This section lists various parts that are available for replacement on the FSH2 FSH -2A, FSH -2A -99 and FSH- 2A -99W If you require assistance or need repairs please contact your area developer for a service agency in your area For further assistance, please contact the Giles Enterprises, Inc. factory at the following phone numbers. IN THE UNITED STATES, CANADA or MEXICO Please call 1- 800 288 -1555 during normal business hours, 8:00AM- 5:OOPM Central Time Zone. For emer- gency equipment repair service, after normal business hours, call 1- 800 288 -1555, extension 314 IN ALL OTHER COUNTRIES Please call 1- 334-272 -3528 during normal business hours, 8:OOAM- 5:OOPM Central Time Zone For emer- gency equipment repair service, after normal business hours call, 1- 334-272 -3528 extension 314 INTERNET Please visit our website on the world wide web at: www.ailesent.com The goal of the Giles team of professionals is to provide you with the highest quality of service and assis- tance You can help us accomplish this by obtaining the following information and having it readily avail- able when calling. The information is recorded on the Serial Plate attached to the rear of the unit. The area below may be helpful in recording information for use as a quick reference Model: Serial Number Phase Voltage: Model: FSH -2, FSH- 2A -99, FSH- 2A -99W Serial Plate information 47 Model. FSH -2, FSH- 2A -99, FSH- 2A -99W Parts List -Not shown -UV Only -Not shown and 1LS only 48 Parts List 7- r: front Ve ntle Hoo Item No Part No. Qty Description *1 90254 1 FILTER ACCESS PANEL, WELD ASSY (NON UV) **1 90262 1 FILTER ACCESS PANEL, ASSY, FSH -2 -UV 2 20520 1 FILTER, EAC, 20 IN 3 30248 1 FILTER, CHARCOAL, ASSY, 20 X 12.375 X 2 *4 90226 1 LAMP ASSY 16-IN UV, REPLACEMENT ONLY *5 23200 1 SWITCH SNAP ACTION ROLLER TYP 6 21125 1 BOARD CONTACT EAC, VH UNITS 7 30206 1 DRIP CUP WELD ASSY 8 34750 1 PIN DRIP CUP SAFETY 9 42300 1 FILTER, BAFFLE, 20X20 S /S, LARGE VH 10 24209 1 LED AIR FILTER, EAC *11 23173 1 SWITCH MOMENTARY 12 22277 1 INDICATOR LIGHT GREEN 13 21190 1 SWITCH, ROCKER, ON -OFF 250V, 20A, DPST 14 64460 1 LABEL, CONTROL PANEL, FSH -2 15 38213 1 INDICATOR LIGHT ORANGE 16 38214 1 INDICATOR LIGHT RED -Not shown -UV Only -Not shown and ILS only Model: FSH -2, FSH- 2A -99, FSH- 2A -99W 49 Model: FSH-2, FSH-2A-99, FSH-2A-99W ,•7-•03.y•Wntles..lidod.-;Reaf -Not shown -UV Only -Not shown, ILS only 50 (FSH-2A, FSH-2A-99, and FSH-2A-99W) Parts List (FSH-2) Parts List Parts 'List for Ventless :Hood.: Rea!,. Item No. Part No Qty 1 39272 1 TANK, 1.5 GAL. LABEL ASSY *2 23778 1 SWITCH, SIDE ROTARY 240V, 30A, W/O ARM *3 23779 1 ROD ADJUSTMENT 4 33589 1 BLOWER, ASSY, VH- FRYERS 5 46125 1 DAMPER, FIRE, 10 X 10 285 DEG LINK 6 24237 1 SWITCH PLUNGER, 250V 15A 7 23001 1 SWITCH VACUUM HOSE BARB 8 20002 1 SWITCH ANSUL, SHUTDOWN /ALARM 15A, 120V 9 40132 1 BRACKET RELEASE, ANSUL 10 23776 1 MODULE, AIR FILTER, ALARM AND SHUTDOWN 11 24208 1 POWER SUPPLY, W/DRIVER BRD 208- 240V,EAC 12 23751 1 TERMINAL BLOCK, MA106 13 23782 1 SONALERT 250V CONTINUOUS BEEP 14 22950 1 SONALERT 250V, INTERMITTENT 15 21191 1 RELAY 30A, 208V 2PL 15 21174 1 RELAY 30A, 240V 2PL *16 20373 1 UV-LAMP ASSY (BALLSAT LAMP) -Not shown -UV Only -Not shown, ILS only Description Model: FSH -2, FSH- 2A -99, FSH- 2A -99W 51 Model: FSH -2, FSH- 2A -99, FSH- 2A -99W Notes: 52 Parts List a� F N a) 2 a) 0) Co a) 'C) O N a-+ C O a) O a) Sl O L Co a) co c 0 To Q1 (n a) 4- a) a) to a 0) N Q (*1 a- m -0 LL Co Model: FSH -2, FSH- 2A -99, FSH- 2A -99W 54 8- Wiring Diagram FSH-2, FSH-2A, FSH- 2A -99W 208-240/60/1 i Noy.. G 6 I 0 S 7 Wiring Diagram WIRING DIAGRAM P/N 32353 -I Wiring Diagram s List for Wiring Diagram :ESN-2, .FSH -2A FSH 2A -99W 208-240/60/1 Item I Part No 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 21125 24208 23001 38215 23751 33589 24300 21190 24237 21174 32114 23776 23200 23782 22950 21182 24209 20002 20298 25275 38214 38213 Qty 1 1 1 1 1 1 2 P 1 1 1 1 1 1 1 1 1 1 1 1 1 2 1 1 Description BOARD, CONTACT, EAC, VH UNITS POWER SUPPLY, W/DRIVER BRD. 208- 240V.EAC SWITCH, VACUUM, HOSE BARB INDICATOR LIGHT, GREEN TERMINAL BLOCK, MA106,6.POLE BLOWER, ASSY, CF- 400VH, CF -500VH BOX, 1/2° UTILITY SWITCH, ROCKER, ON-Oft 250V,, 20A, DPST SWITCH, PLUNGER, 250V, 15A RELAY 30A, 240V, 2 POLE BAFFLE FILTER SWITCH, ASSY, CF- 400/500VH MODULE, AIR FILTER, ALARM AND SHUTDOWN SWITCH, SNAP ACTION, ROLLER TYPE SONALERT 250V, CONTINUOUS BEEP SONALERT 250V, INTERMITTENT SWITCH. PRESSURE, FIREBUTLER. 40PSI LED, AIR FILTER, EAC SWITCH, ANSUL, SHUTDOWN/ALARM, 15A, 120V CONTACTOR LOAD CENTER BRAID. COPPER SHIELDING WIRENUT IDEAL BLUE INDICATOR LIGHT ORANGE INDICATOR LIGHT, RED Model: FSH -2, FSH- 2A -99, FSH- 2A -99W 55 mm I oa I tlQ e0 1 Li aan WAAL d .r wa PO 0. MOO Peen 4 _oar n WIRING DIAGRAM FSH -2, FSH -2A, FSH- 2A -99W 208- 240/60/1 W /ILS MANUAL PUSH TO START AFTER POWER INTERRUPT n YLiesaaorrwMIL I eam Poo men MO o 0Y- u o o a- u o 1 J L_ J® m0e0M Wiring Diagram agram FSH -2 :FSH -2A, "FSH 2A -99W 268-240/60/1 w lL Item Part No Qty Description 1 I 21125 1 1 I BOARD. CONTACT. EAC. VH UNITS 2 24208 1 POWER SUPPLY, WIDRIVER BRD, 208- 240V.EAC 3 23001 1 SWITCH, VACUUM, HOSE BARB 4 38275 7 INDICATOR LIGHT GREEN 5 23751 1 TERMINAL BLOCK MA106.6 POLE 6 33589 1 BLOWER, ASSY, CF -400VH, CF500VH 7 24300 2 BOX. 1/2° UTILITY 8 21190 1 SWITCH, ROCKER. ON -OFF, 250V, 20A, DPST 9 24237 1 SWITCH, PLUNGER, 250V. 15A 10 21174 1 RELAY, 30A, 240V, 2 POLE 11 32114 1 BAFFLE FILTER SWITCH, ASSY CF- 4001500VH 12 23776 1 MODULE, AIR FILTER, ALARM AND SHUTDOWN 13 23200 1 SWITCH, SNAP ACTION, ROLLER TYPE 14 23782 1 SONALERT, 250V, CONTINUOUS BEEP 15 22950 1 SONALERT, 250V. INTERMITTENT 16 21182 1 SWITCH, PRESSURE, FIREBUTLER, 40PSI 17 24209 1 LED, AIR FILTER, EAC 18 20002 1 SWITCH. ANSUL. SHUTDOWN /ALARM, 15A, 120V 19 1 CONTACTOR 20 1 LOAD CENTER 21 23173 1 SWITCH, PUSH BUTTON, MOMENTARY 22 20298 1 BRAID. COPPER SHIELDING 23 25275 2 WIRENUT, IDEAL BLUE 24 38214 1 INDICATOR LIGHT ORANGE 25 1 38213 I 1 INDICATOR LIGHT, RED Model: FSH -2, FSH- 2A -99, FSH- 2A -99W 57 7 -1 0+ WIRING DIAGRAM FSH-2, FSH-2A, FSH-2A-99W WITH UV 208-240/60/1 0 0 aim ea 01- IlUb 19 ON Ifirti tat milf "11. ORM Mal resa rilicuOt COM. Ma C) co C a Wiring Diagram 8 P arts List for Wiring Diagram FSH 2,' FSH -2A, FSH 2A -99W 208-240/60/1 WI;UV: Item I Part No Qty Description 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 21125 24208 23001 38215 23751 33589 24300 21190 24237 21174 32114 23776 23200 23782 22950 21182 24209 20002 20298 25275 38214 38213 25300 20373 90226 BOARD. CONTACT. EAC. VH UNITS POWER SUPPLY, W/DRIVER BRD, 208- 240V.EAC SWITCH, VACUUM, HOSE BARB INDICATOR LIGHT GREEN TERMINAL BLOCK, MA106.6 POLE BLOWER, ASSY, CF -400VH, CF 500VH BOX, 1/2° UTILITY SWITCH, ROCKER, ON -OFF, 250V, 20A. DPST SWITCH, PLUNGER, 250V, 15A RELAY, 30A. 240V. 2 POLE BAFFLE FILTER SWITCH, ASSY, CF- 400 /500VH MODULE, AIR FILTER, ALARM AND SHUTDOWN SWITCH, SNAP ACTION, ROLLER TYPE SONALERT 250V. CONTINUOUS BEEP SONALERT, 250V. INTERMITTENT SWITCH, PRESSURE, FIREBUTLER, 40PSI LED, AIR FILTER, EAC SWITCH, ANSUL. SHUTDOWN /ALARM, 15A. 120V CONTACTOR LOAD CENTER BRAID. COPPER SHIELDING WIRENUT, IDEAL BLUE INDICATOR LIGHT ORANGE INDICATOR LIGHT, RED WIRENUT, ORANGE UV -LAMP ASSY (BALLAST AND LAMP) LAMP ASSY 16-IN, UV REPLACEMENT ONLY Model: FSH -2, FSH- 2A -99, FSH- 2A -99W 59 p 9 9 O ��yM�•- r KW M00 0 �---Ia WO MIIMO r .-10 8 Wt. 0000 si O O— ONO AIM r -1 n 0pat wS" 0 r WIRING DIAGRAM FSH -2, FSH -2A, FSH- 2A -99W WITH UV /ILS 208 240/60/1 MANUAL PUSH /HOLD TO START AFTER POWER INTERRUPT 0 a en wm ua u roe ft -11011110. 0:001 rglee V Wiring Diagram arts List: for Wiring Diagram FSH -2,,' FSH -2A, &:FSH -2A99W 208 240/60/1 wf U:V &'ILS. Item 1 Part No ,j Qty 1 Description 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 21125 1 I BOARD, CONTACT EAC, VH UNITS 24208 1 1 POWER SUPPLY, W /DRIVER BRO. 208-240V,EAC 23001 1 1 SWITCH, VACUUM. HOSE BARB 38215 1 INDICATOR LIGHT, GREEN 23751 1 TERMINAL BLOCK. MA106.6 POLE 33589 1 BLOWER. ASSY. CF- 400VH. CF-500VH 24300 2 BOX 1/2° UTILITY 21190 1 SWITCH, ROCKER, ON -OFF 250V, 20A, DPST 24237 1 SWITCH, PLUNGER. 250V. 15A 21174 1 RELAY, 30A, 240V, 2 POLE 32114 1 BAFFLE FILTER SWITCH, ASSY CF- 4400/500VH 23776 1 MODULE, AIR FILTER. ALARM AND SHUTDOWN 23200 1 SWITCH, SNAP ACTION, ROLLER TYPE 23782 1 SONALERT, 250V, CONTINUOUS BEEP 22950 1 SONALERT, 250V. INTERMITTENT 21182 1 SWITCH, PRESSURE, FIREBUTLER, 40PSI 24209 1 LED, AIR FILTER, EAC 20002 1 SWITCH, ANSUL. SHUTDOWN /ALARM, 15A, 120V 1 CONTACTOR 1 LOAD CENTER 20298 1 BRAID, COPPER SHIELDING 25275 2 WIRENUT, BLUE 38214 1 LIGHT. INDICATOR, RED 38213 1 LIGHT INDICATOR. ORANGE 25300 1 WIRENUT ORANGE 20373 1 UV -LAMP ASSY (BALLAST AND LAMP) 90226 1 LAMP ASSY, 16-IN. UV, REPLACEMENT ONLY 23173 I 1 SWITCH, PUSH BUTTON, MOMENTARY Model: FSH -2, FSH- 2A -99, FSH- 2A -99W 61 FSN -f i FSH.2A-99r N FSH SOw Vdiring Diagram DIA GRAM PIS WIRING DIAGRAM Wiring Diagram List for Wiring Diagram FSH -99 ONLY 208-240/60/1 Item Part No I Qty 01 I 21125 1 02 24208 1 03 23001 1 04 38215 05 23751 1 06 33589 1 07 32208 2 08 21190 1 09 24237 1 10 20370 1 11 32114 1 12 23776 1 13 23200 1 14 23782 1 15 22950 1 16 21182 1 17 24209 1 18 20002 1 19 21900 1 20 21950 1 21 20298 1 22 25275 1 23 38214 1 24 38213 1 25 20303 1 26 20304 1 27 20319 1 28 20320 1 Description BOARD, CONTACT, EAC, VH UNITS POWER SUPPLY, W/DRIVER BRD, 208- 240V.EAC SWITCH, VACUUM, HOSE BARB INDICATOR LIGHT GREEN TERMINAL BLOCK, MA106,6 POLE BLOWER, ASSY, CF- 400VH, CF 500VH CONTACTOR, ASSY, 208/24OVAC, 3PH SWITCH, ROCKER, ON -OFF 250V, 20A, DPST SWITCH, PLUNGER, 250V, i5A RECEPTACLE, 50A 3PH, 4 WIRE BAFFLE FILTER SWITCH, ASSY, CF- 400 /500VH MODULE, AIR FILTER, ALARM AND SHUTDOWN SWITCH, SNAP ACTION, ROLLER TYPE SONALERT 250V, CONTINUOUS BEEP SONALERT 250V, INTERMITTENT SWITCH, PRESSURE, FIREBUTLER, 40PSI LED, AIR FILTER, EAC SWITCH, ANSUL, SHUTDOWN/ALARM, 15A, 120V FUSE, 15 -AMP SC 15 HOLDER, FUSE, 300V, 15A SC OTO 15 BRAID, COPPER SHIELDING WIRENUT, IDEAL BLUE INDICATOR LIGHT, ORANGE INDICATOR LIGHT. RED TERMINAL BLOCK, 4-12 GA WIRE TERMINAL BLOCK, GROUND, 4-12 GA WIRE TERMINAL BLOCK 50 AMP AWG 8-24 TERMINAL BLOCK, GROUND, AWG 8-24 Model: FSH -2, FSH- 2A -99, FSH- 2A -99W 63 FSH 2. fSH 99. FSH -2A- 41- Wiring Diagram 'VT CO a, 01 1 g 0 0 z a DIAGRAM PIN WIRING DIAGRAM Wiring Diagram List for Wiring Diagram FSH 2A- 99.ONLY 208-240/6011 w /.ILS Item 01 02 03 04 05 06 07 08 09 10 71 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 Part No Qty. 21125 24208 23001 38215 23751 33589 32208 21190 24237 20370 32774 23776 23200 23782 22950 21182 24209 20002 21900 21950 20298 25275 38214 38213 20303 20304 20319 20320 23173 21174 Description BOARD, CONTACT, EAC, VH UNITS POWER SUPPLY, W /DRIVER BRD, 208- 240V,EAC SWITCH, VACUUM, HOSE BARB INDICATOR LIGHT. GREEN TERMINAL BLOCK, MA106,6 POLE BLOWER, ASSY,, CF- 400VH. CF 500VH CONTACTOR, ASSY, 208/240VAC. 3PH SWITCH, ROCKER. ON -OFF 250V, 20A, DPST SWITCH, PLUNGER, 250V i5A RECEPTACLE. 50A, 3PH, 4 WIRE BAFFLE FILTER SWITCH, ASSY CF- 400/500VH MODULE, AIR FILTER. ALARM AND SHUTDOWN SWITCH, SNAP ACTION, ROLLER TYPE SONALERT 250V, CONTINUOUS BEEP SONALERT, 250V, INTERMITTENT SWITCH, PRESSURE, FIREBUTLER, 40PSI LED, AIR FILTER. EAC SWITCH. ANSUL. SHUTDOWN /ALARM, 15A. 120V FUSE, 15-AMP SC -15 HOLDER, FUSE, 300V. 15A, SC OTO 15 BRAID. COPPER SHIELDING WIRENU, IDEAL BLUE INDICATOR LIGHT ORANGE INDICATOR LIGHT RED TERMINAL BLOCK, 4-12 GA WIRE TERMINAL BLOCK, GROUND, 4-12 GA WIRE TERMINAL BLOCK. 50 AMP. AWG 8-24 TERMINAL BLOCK, GROUND. AWG 8-24 SWITCH, PUSH BUTTON, MOMENTARY RELAY, 30A, 240V, 2PL Model: FSH -2, FSH- 2A -99, FSH- 2A -99W 65 fez q0 t e a —G W 208- 240/60/3 M W /PLUG A WIR�NO 0000M F94-2A-99 Wiring Diagram Parts List for Winng Diagram FSH -2A -99 ONLY 208-240/60/1 virI "U' Item Part No I Qty Description 01 21125 I 1 02 24208 1 03 23001 1 04 38215 1 05 23751 1 06 33589 1 07 32208 2 08 21190 1 09 24237 1 10 20370 1 11 32114 12 23776 1 13 23200 1 14 23782 1 15 22950 1 16 21182 1 17 24209 1 18 20002 1 19 21900 1 20 21950 1 21 20298 1 22 25275 1 23 38214 1 24 38213 1 25 20303 3 26 20304 2 27 20319 2 28 20320 1 29 20304 2 30 20373 1 31 90226 I 1 BOARD, CONTACT EAC, VH UNITS POWER SUPPLY, W /DRIVER BRD, 208- 240V,EAC SWITCH, VACUUM, HOSE BARB INDICATOR LIGHT GREEN TERMINAL BLOCK, MA106,6 POLE BLOWER, ASSY, CF- 400VH, CF500VH CONTACTOR, ASSY, 208/240VAC, 3PH SWITCH, ROCKER, ON -OFF, 250V. 20A, DPST SWITCH, PLUNGER, 250V, 15A RECEPTACLE, 50A. 3PH, 4 WIRE BAFFLE FILTER SWITCH. ASSY CF- 400/500VH MODULE, AIR FILTER, ALARM AND SHUTDOWN SWITCH, SNAP ACTION, ROLLER TYPE SONALERT, 250V, CONTINUOUS BEEP SONALERT 250V, INTERMITTENT SWITCH, PRESSURE, FIREBUTLER, 40PSI LED, AIR FILTER. EAC SWITCH, ANSUL, SHUTDOWN /ALARM, 15A, 120V FUSE, 15 -AMR SC 15 HOLDER. FUSE. 300V, 15A. SC OTO 15 BRAID, COPPER SHIELDING WIRENUT, IDEAL BLUE INDICATOR LIGHT. ORANGE INDICATOR LIGHT, RED TERMINAL BLOCK, 4-12 GA WIRE TERMINAL BLOCK. GROUND. 4-12 GA WIRE TERMINAL BLOCK, 50 AMP AWG 8-24 TERMINAL BLOCK. GROUND. AWG 8-24 TERMINAL BLOCK, GROUND, 4-12 GA WIRE UV -LAMP ASSY (BALLAST AND LAMP) LAMP ASSY, 16-IN, UV, REPLACEMENT ONLY Model: FSH -2, FSH- 2A -99, FSH- 2A -99W 67 ASH 2t fS H- 21k-99, Mo W fSH -2�► g �F 4 J ,ring Diagram i M PIN. IRING9 p& Wiring Diagram Model: FSH -2, FSH- 2A -99, FSH- 2A -99W Item Part No. ,y Qty Description 01 21125 I 1 02 24208 1 03 23001 I 1 04 38215 1 05 23751 1 06 33589 1 07 32208 2 08 21190 1 09 24237 1 10 20370 1 11 32114 1 12 23776 1 13 23200 1 14 23782 1 15 22950 1 16 21182 1 17 24209 1 18 20002 1 19 21900 1 20 21950 1 21 20298 1 22 25275 1 23 38214 1 24 38213 1 25 20303 1 26 20304 1 27 20319 1 28 20320 1 29 20304 1 30 20373 1 31 90226 1 32 23173 1 33 21174 1 BOARD, CONTACT EAC, VH UNITS POWER SUPPLY, W /DRIVER BRD, 208- 240V,EAC SWITCH, VACUUM, HOSE BARB INDICATOR LIGHT, GREEN TERMINAL BLOCK, MA106.6 POLE BLOWER, ASSY, CF- 400VH, CF500VH CONTACTOR, ASSY, 208/240VAC. 3PH SWITCH, ,ROCKER, ON -OFF, 250V, 20A, DPST SWITCH, PLUNGER, 250V. 15A RECEPTACLE. 50A. 3PH. 4 WIRE BAFFLE FILTER SWITCH, ASSY CF- 4001500VH MODULE, AIR FILTER, ALARM AND SHUTDOWN SWITCH. SNAP ACTION. ROLLER TYPE SONALERT, 250V, CONTINUOUS BEEP SONALERT, 250V, INTERMITTENT SWITCH, PRESSURE. FIREBUTLER. 40PSI LED, AIR FILL ER. EAC SWITCH, ANSUL, SHUTDOWN /ALARM, 15A, 120V FUSE, 15-AMP SC 15 HOLDER, FUSE, 300V, 15A, SC OTO 15 BRAID, COPPER SHIELDING WIRENUT, IDEAL BLUE INDICATOR LIGHT, ORANGE INDICATOR LIGHT RED I ERMINAL BLOCK, 4 -12 GA WIRE TERMINAL BLOCK, GROUND, 4-12 GA WIRE TERMINAL BLOCK, 50 AMP AWG 8-24 TERMINAL BLOCK, GROUND, AWG 8-24 TERMINAL BLOCK, GROUND, 4-12 GA WIRE UV -LAMP ASSY (BALLAST AND LAMP) LAMP ASSY. 16-IN, .UV, REPLACEMENT ONLY SWITCH, PUSH BUTTON, MOMENTARY RELAY, 30A, 240V, 2PL 69 Model: FSH -2, FSH- 2A -99, FSH- 2A -99W '8- `Parts List fog FSH-2A-99, Wiring Diagram FSH-2, FSH-2A, FSH -2A 99, &FSH- 2A -99W 220/50/1 70 I I ®t4 21_1__ Wiring Diagram a WIRING DIAGRAM P/N 36306 -E Wiring Diagram s "List for Winn iagram >'FSH -2, FSH-2A, FSH -2A =99 FSH 2A- .99W.220/50/1 Item I Part No I Qty 1 Description 1 21125 1 2 24208 1 3 23001 1 4 38215 1 5 23751 1 6 33589 1 7 24300 2 8 21190 1 9 24237 1 10 21174 1 11 32114 1 12 23776 1 13 23200 1 14 23782 1 15 22950 1 16 21182 1 17 24209 1 18 20002 1 19 1 20 1 21 20298 1 22 25275 1 23 38214 1 24 38213 1 BOARD, CONTACT EAC, VH UNITS POWER SUPPLY, W/DRIVER BRD, 208- 240V,EAC SWITCH, VACUUM, HOSE BARB INDICATOR LIGHT GREEN TERMINAL BLOCK, MA106,6 POLE BLOWER, ASS'Y', CF-400VH, CF 500VH BOX, 1/2° UTILITY SWITCH, ROCKER, ON -OFF 250V, 20A, DPST SWITCH, PLUNGER, 250V, 15A RELAY, 30A, 240V, 2 POLE BAFFLE FILTER SWITCH, ASSY CF- 400/500VH MODULE, AIR FILTER, ALARM AND SHUTDOWN SWITCH, SNAP ACTION, ROLLER TYPE SONALERT, 250V, CONTINUOUS BEEP SONALERT 250V, INTERMITTENT SWITCH, PRESSURE, FIREBUTLER, 40PSI LED, AIR FILTER, EAC SWITCH, ANSUL, SHUTDOWN /ALARM, 15A, 120V CONTACTOR LOAD CENTER BRAID, COPPER SHIELDING WIRENUT, IDEAL BLUE INDICATOR LIGHT, RED INDICATOR LIGHT ORANGE Model: FSH -2, FSH- 2A -99, FSH- 2A -99W 71 Model- FSH -2, FSH- 2A -99, FSH- 2A -99W Notes: 72 Wiring Diagram GLem FOODSERVICE EQUIPMENT Giles Enterprises, Inc. P.O Box 210247 2750 Gunter Park Drive West Monigcrinery. Al 36121-0247 USA (334) 272-1457 3— Hotline 1-800 Canada Only) FAX (334) 272 3561 www.gilesent.com Form No. 60200 (Release dm: 07198)(Rmision ()me: 01128109)(Rev F)