Loading...
HomeMy WebLinkAbout105 W 8th St - Technical T E C HNICAL Permit# II-5 Address 1 °6' IN g -ri'` y� Project description coGmi cx,i,c. SvPrresstan s Ctm. Date the permit was finaled co(�1- Iii Number of technical pages 3 o“, Ali r L 4, S'..157 LS. A p az zio, CS Wes' 8 th S.,rfet A-[: 9 WA 98362 7: 3y: 41 li?'1Ece SEte 6L7 WzsEil!lltEtorr. 98382 (36C .(C10..2972 ?hone (3CDC) 4/12/2011 1 1 P POTTER PFC- 4410RC The Symbol of Protection RELEASING CONTROL PANEL Multi Hazard Operation Four Class B Initiating Circuits Two Class B Supervisory Circuits Four Class B Output Circuits Programmable Cross Zoning Supervised Microprocessor 32 Character Alpha- Numeric LCD Display Custom Banner Message and Zone Description text Custom Zone Description Text ,I I On Board Menu Driven Programming Controls I I Releasing Circuits Protected From False Activation Continuous or Timed Discharge 40 Event History Buffer Walktest with Automatic Time -out Alarm, Trouble Supervisory, and Waterflow relays II. Optional. Class A Initiating Zone and output module 34 character LED supplemental display 19 Standard Programs in Panel Memory Password Protection for all Programming 24 Hour Clock Suitable for agent or water -based extinguishing Programmable pre discharge timers* One Class B Abort circuit* (Defaults to additional supervisory zone in water based mode.) Dimensions: 18 1/4" x 14 x 4 3 /4" Three Abort modes* UL and ULC Listed, FM Approved, NYMEA Accepted, and Available in Chemical mode only CSFM Approved One zone programmable as abort in chemical mode. General Description The Potter Model PFC- 4410RCis a flexible multi hazard releasing control The panel is Ninth Edition UL listed, ULC listed, Factory Mutual, panel that is well suited for a number of applications. The PFC- 441ORC California State Fire Marshal (CSFM)andNew YorkMaterials Equipment is listed for use with pre- action and deluge sprinkler suppression systems Acceptance (MEA) approved. and agent based fire suppression systems. The PFC- 4410RC is housed in a durable steel cabinet with removable The panel utilizes a microprocessor -based system that has 19 Standard door and key lock. The panel is available in either a red or white finish Programs, which covers a majority of installations. The simple to follow and an optional flush mount trim ring is available. The cabinet contains Menu Structure programs the entire system in a matter of minutes. In knockouts on the side, back and top of the cabinet to ease installation. addition to the Standard Programs, the panel allows custom programming In addition, the cabinet will house up to 18 amp -hour batteries that will to accommodate any installation. provide in excess of 90 hours of standby power. Ordering Information Model Number Description Stock Number PFC- 4410RC 4 Zone Releasing Control (White Cabinet) 3006144 PFC- 4410RC 4 Zone Releasing Control (Red Cabinet) 3006142 PFC -TW Bezel for Semi -Flush Mounting (White) 5090157 PFC -TR Bezel for Semi -Flush Mounting (Red) 5090155 BT -40 Battery, 12V 4AH for 24 hour standby (2 Req'd) 5130092 BT -80 Battery, 12V 8AH for 60 hour standby (2 Req'd) 5130084 BT -120 Battery, 12V 12AH for 90 hour standby (2 Req'd) 5130090 BT -180 Battery, 12V, 18AH for 90 hour standby (2 Req'd) 5130086 CA2Z 2 Zone Class A Initiating Circuit Module 3006013 CAM Class A Indicating Circuit Module 3005300 ARM -44 Relay Module for PFC- 4410RC 3006221 ARM -2 Auxiliary Relay Module 3004725 RA- 4410RC Remote Annunciator 3006400 BB- RA -44R Surface Mount Back Box for RA- 4410RC (Red) 3006401 Potter Electric Signal Co., LLC St. Louis, MO Cust Service: 866 240 -1870 Tech Support:866- 956 -1211• Canada 888 882 -1833 www.pottersignal.com PRINTED IN USA MFG #5401250 REV A PAGE 1 OF 2 12/09 P POTTER PFC- 4410RC a The Symbol of Protection RELEASING CONTROL PANEL Architects /Engineers Specifications The control panel for the extinguishing agent releasing system shall Waterflow, Linear Heat Detection (up to 10,000 feet per zone), be a microprocessor based control capable of protecting multiple Manual Release, Low Air Alarm, Supervisory, Tamper, Low Air or hazards in one control panel. It shall be Underwriters Laboratories High Air. Inc. listed under Standard 864 Ninth Edition and Underwriters Optional Class A modules, CA2Z, may be added for Class A Laboratories of Canada for Local Control Units for Releasing Service. operation. The panel shall have a Low Air Zone that creates a The control shall also be approved by Factory Mutual Research supervisory condition and map to an output. UL and ULC Listed, FM Corporation and be compliant with the requirements of NFPA -72 Approved, NYMEAAccepted, CSFM Approved (Local: A, M, SS service types; DAC and NC signaling type) and The control shall have two fully supervised Class B (Style B) NFPAl2, NFPAl2A, NFPA -13, NFPA -15, NFPA -16, NFPA -17, supervisory circuits. These circuits shall be selectable through the NFPA -17A, NFPA -750, and NFPA -2001. programming sequence to operate in one of the following modes: The control shall be housed in an 18 gauge steel cabinet that has a Supervisory, Tamper, Low Air or High Air. hinged, removable door with a key lock. The finish shall be baked The control shall have one fully supervised class B (style B) Abort enamel and available in red or off -white with contrasting trim and circuit with 3 different operating modes, ULI, IRI, and NYC. logo. An optional matching bezel should be available for semi -flush mounting. The cabinet shall have adequate space to house 18 AH The control shall have four fully supervised Class B (Style Y) output standby batteries capable of operating the system for at least 90 hours. circuits. These circuits shall be selectable through the programming sequence to operate as one of the following: Alarm Notification The control shall include a fully supervised integral power Appliance, Supervisory Notification Appliance, Trouble Notification supply /battery charger capable of providing 200mA to the auxiliary Appliance or Releasing. The optional CAM module may be added to power circuit. It shall also be capable of providing 2.5 Amps to all convert the outputs to Class A. releasing and notification appliance circuits combined. All initiating, output and auxiliary power circuits shall be power limited. The panel shall have an RS -485 output and auxiliary power outputs for connection and supervision of up to 4 remote annunciators or an The control shall have a 32 character (16 characters, 2 lines) backlit ARM -44 Relay Module and 3 annunciators. LCD display and a 34 LED supplemental display. All diagnostic and alarm event information shall be viewable in text form on this display. The releasing circuits shall be supervised for short circuit conditions A field programmable custom banner message with the current date and shall be programmable for cross zoning operation when required. and time shall be displayed when no current alarm or diagnostic The discharge timer for these releasing circuits shall be programmable information exists. for times of 7, 8, 9, 10, 20 minutes or continuous. All initiating and output circuits shall be capable of being individually disabled or All operational features of the control panel shall be field enabled. In addition, when in the agent extinguishing mode there shall programmable using menu driven selections on the alpha- numeric be a pre- discharge timer adjustable from 0 -60 seconds from an alarm display and on board controls. No special programmer will be zone or 0 -30 seconds from a manual release zone. required and jumpers or switches to configure operational features shall not be permitted. Alarm and trouble indications shall resound The control shall have a test mode that will automatically disable when required. all releasing circuits. The test mode shall operate in such a manner as to automatically reset the initiating circuit and indicating circuits The control panel shall be equipped with 19 programs built into the after detecting each alarm condition initiated by the test. All testing panel memory, 13 for water based extinguishing and 6 for agent shall be recorded in the 40 event history buffer. The test mode will extinguishing. In addition, the panel shall have the ability to add custom automatically terminate after twenty minutes of inactivity. programs. All programming functions shall be password protected. The control shall have four integral relay contacts rated 3 Amps at 30 The control shall have four fully supervised Class B (Style B) VDC for connection to external auxiliary equipment. One relay shall initiating circuits capable of supporting the operation of 25 compatible operate when an alarm condition occurs, another when a trouble signal 2 -wire smoke detectors on each circuit. occurs, the third when a supervisory condition occurs, and the fourth The individual circuits shall be selectable through the programming during a waterflow condition. sequence to operate in one of the following modes: Conventional, UL and ULC Listed, FM Approved, NYMEAAccepted, CSFM Approved. PRINTED IN USA MFG #5401250 REV A PAGE 2 OF 2 12/09 P PO1TUER MR -100 200 SERIES R The Symbol of Protection MULTI VOLTAGE CONTROL RELAYS Relay may be energized from avoltage source of 18 to 35VDC/VAC, 115 VAC or 230VAC. r Each relay position contains a red LED which illuminates when the coil t f is energized. This provides a time saving convenience when checking an il j installed system, no metering is required. 1' Single, dual, or triple relay modules may be "snapped apart" from standard ?-,-;;.'11- f. 4 position master. "SNAP APART" SEAMS For continuous duty use. Available in dust proof enclosures with LED viewing port. Track mounting hardware to facilitate installation in standard cabinets. UL recognized relays rated at 10,000,000 mechanical operations. UL Listed as Control Unit Accessory. Dimensions i ll MR- 101/T, MR- 201/T: MR- 104/x, MR -204/T (Similar) 3.25" (82.6mm) H x 2.125" (54mm) W x 1.5" (38. I mm) D MR- 104/T, MR- 204/T: ti./ 3.25" (82.6mm) H x 8.5" (215.0mm) x 1.5" (38.1mm) D Al∎ MR- 101 /C, MR- 201 /C: I 5.125" (130.2mm)H x 3.125" (79.0mm) W x 2.5" (63.5mm) Made in V MR- 104 /C, MR- 204/C: I M Recognized Component ..°1 5.125" (130.2mm)H x 9.5" (241.3mm) W x 2.5" (63.5mm) D .6. Product Description Ordering Information The MR Series Multi voltage Control Relays offer SPDT or DPDT 10 Amp MR-101/T 1000260 Single SPDT Relay with LED and resistive contacts which may be operated by one of four input control voltages. A track mounting hardware. single relay may be energized from a voltage source of 24VDC, 24VAC, 115VAC, (UL Recognized) or 230VAC by wiring to appropriate input terminals. MR -101 /C 1000259 Single SPDT Relay with LED Each relay position contains a red light emitting diode (LED) which indicates the mounted in an enclosure. relay coil is energized. Relays may be "snapped apart" from a standard 4 module (UL Listed) assembly and used independently. MR -104/f N/S 4- position SPDT Relay with LEDs These devices are ideal for applications where local contacts are required for and track mounting hardware. system status, remote contacts for control of electrical loads and general purpose 4-p Re MR -104 /C N/S 4- position SPDT Relay with LEDs switching. They are suitable for use with HVAC, Temperature Control, Fire mounted in an enclosure. Alarm, Security, Energy Management, and Lighting Control systems. (UL Listed) MR -201/T N/S Single DPDT Relay with LEDs Power Requirements: MR -101 Position Track mounting hardware. 15mA 24VDC (UL Recognized) 30mA 24VAC MR -201 /C 1000258 Single DPDT Relay with LED 20mA 115VAC mounted in an enclosure. 20mA 230VAC (UL Listed) MR -201 Position MR-204/T N/S 4- position DPDT Relay with LEDs 30mA 24 VAC track mounted hardware. 39mA @24VAC (UL Recognized) 35mA 115VAC MR-204 /C N/S 4- position DPDT Relay with LEDs 35mA 230VAC mounted in an enclosure. (UL Recognized) Pull -In Voltage: 75% of nominal voltage, *N /S =Non -Stock Item (Special Order) Max. 25 °C Drop -Out Voltage: 25% of nominal voltage, Installation Wiring (Typical for module position) Min. 25 °C Enclosure: Backbox: 18 ga. CRS, plated with 1/2" SPDT DPDT Conduit Knockouts 1 1* 1 1 t i j Cov ABS -94V0 Contact Rating: 10A Res. 115VAC, 7A Res. 230VAC, /IBM fa i as�o tO 7A Res. 28 VAC, N.O. 1 /6 HP 115 VAC, N.C. 1/8 HP 115VAC Ambient Temperature: 32 °F to 120 °F j 1 lo m co ell 6p. MINN* I Approvals: MR- 101 /C, MR- 104 /C, MR- 201 /C, MR- x e IS n 1 I I ,n w 204/C, U.L. Listed File #S3403, City of vottms New York MEA #73 -92 -E, CSFM #7300- C112Pi i n+ 1301162 1004:101 MR -lol '°v- '°—ese ei tee""`"- 0orit�r MR -201 (MR -104) '''°VAA,_...Q0` j:1 mvwa 000n, (MR -204) a— ary..r e.uwd,.wie. Potter Electric Signal Company 2081 Craig Road, St. Louis, MO, 63146 -4161 Phone: 800 325- 3936 /Canada 888 882 -1833 www.pottersignal.com PRINTED IN USA MFG. #5401100 REV B PAGE 1 OF I 9/07 FIRE SUPPRESSION SYSTEMS 1 b PATENTED Electrically Operated Units Features Significantly more effective than alternative extinguishing agents Environmentally friendly -Ozone depletion potential (ODP) 0 No global warming potential Ease of installation no pressure vessels, piping, or expensive installation manpower Very low maintenance Provides reliable, cost effective protection for a wide range of fire hazards Listed for Class A, B, C fires by UL, ULC, CSIRO, ECB, and many others Favorably reviewed by EPA for SNAP listing Suitable for enclosed facilities and local applications Safe for personnel non harmful to personnel at design application rates Safe for valuable equipment -will not harm electronic equipment or magnetic media Post fire cleanup is minimal aerosol suspends in air for quick and easy venting after discharge Compact up to a 90% reduction in space and weight requirements Applications Due to their fast response time, low fire extinguishing concentration, and environmental safety, Stat -X fire suppression systems may be used in critical applications across a wide range of industries. Aerosol generators are currently protecting and are suitable for use in: Telecommunications facilities Flammable liquid storage areas Process control rooms Turbine and generator enclosures PABX rooms Marine engine rooms and machinery spaces High value mobile equipment Power plants Cellular sites and relay towers Small boats Data processing facilities General industrial hazards Operation /Description Upon detection of a fire, Stat -X generators can be activated either manually or automatically from a suitable listed releasing device. All auxiliary system components (release panel, detection, remote pull stations, etc.) are listed /approved by UL, ULC, FM, New York City MEA, and California State Fire Marshall. Upon activation, the generators produce an exceptionally effective, ultra -fine, potassium based aerosol. Unlike gaseous systems, Stat -X aerosol generators are very cost effective to install and maintain as they do not require the pressure vessels, piping or expensive installation costs associated with other extinguishing systems. Space and weight requirements are minimal. On an agent weight basis, Stat -X aerosol is ten times more effective than gaseous agent alternatives. The Stat -X generator's effectiveness is a function of its patented design, aerosol composition, and ultra -fine particle size. Fire suppression is rapidly achieved through interference between the ultra -fine aerosol particulate and the flame's free radicals terminating propagation of the fire. Stat -X aerosol generators are virtually maintenance free and have a service life of over 10 years. This, coupled to their very low installation cost, makes them an extremely cost effective fire protection solution. i PSI eiliniffillellit 1110106111112 General Specifications: Parameter 30 E 60 E 100 E 250 E 500 E 1000 E 1500 E 2500 E Aerosol Mass (kg), .03 .07 .06 .13 .10 .22 .25 .55 .50 1.10 1.00 2.20 1.50 3.3 2.50 5.50 (Ibs) Ship. Wt. /unit packaging (kg), 0.36 0.8 0.48 1.1 1.44 3.2 2.72 6.0 3.63 8.0 7.05 15.5 8.6 19.0 11.3 25.0 (Ibs) Length (mm), (in) 74 2.9 107 4.2 121 4.8 132 5.2 180 7.1 170 6.7 203 8.0 267 10.5 Diameter (mm), (in) 51 2.0 51 2.0 76 3.0 127 5.0 127 5.0 203 8.0 203 8.0 203 8.0 Discharge Time 8.0 8.5 11.5 12.0 21.0 16.0 23.0 37.0 (sec) Initiation Parallel 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 Current (Amp) Series 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 Pulse Duration 50 50 50 50 50 50 50 50 (millisecond) Max. Supervisory 5 005 5. 005 5. 005 5.005 5.005 5.005 5.005 5.005 Current (Amp) Coverage parameters: Model Part Maximum Maximum Area Coverage Maximum Mounting Number Volume Coverage. Height (m (ft (m) (ft) (m) (ft) 30 E 15100 0.45 15.89 1.20 X 1.20 3.95 X 3.95 1.22 4.0 60 E 15110 0.90 31.78 1.70 X 1.70 5.60 X 5.60 2.00 6.6 100 E 15120 1.49 52.71 2.18 X 2.18 7.20 X 7.20 2.50 8.2 250 E 15130 3.73 131.8 3.45 X 3.45 11.3 X 11.3 2.75 9.0 500 E 15140 7.46 263.5 4.88 X 4.88 16.0 X 16.0 3.50 11.5 1000 E 15150 14.9 527.1 4.88 X 4.88 16.0 X 16.0 5.00 16.0 1500 E 15160 22.4 790.6 4.88 X 4.88 16.0 X 16.0 5.00 16.0 2500 E 15170 37.3 1317.7 4.88 X 4.88 16.0 X 16.0 5.00 16.0 For additional information on use of Stat -X systems, please contact your local Distributor or Fireaway. Operation /Storage Parameters: Temperature -40 C to +54 C -40 F to +130 F) Relative Humidity up to 98% at +35 C +95 F) Transportation Classification: f Classification code: 4.1 UN Identification UN 3178 R Packaging group: PGIII UL Shipping limitation: o Ground: None o Max. Weight per unit packaging Cargo Air 100 kgs (2201bs) o Max. Weight per unit packaging Passenger Air 25 kgs (551bs) Stat -X is a registered trademark. Manufactured in the USA and sold worldwide exclusively by Fireaway Inc. under license from Techno -TM LLC 5852 Baker Road. Minnetonka. Minnesota 55345 USA it f Tel: 952.935.9745 Fax: 952.935.9757 www.statx.com Made in the USA Call to discuss your specific requirements with one of our professionals. Ic-i. .r tr y e ,�y i t Ai To: All Stat Distributors RE: Installation of Stat per UL cross listing for Potter 4410RC In order to comply with the UL cross listing for the Potter 4410RC panel an Ematch Protection Device (part number 3005014) must be connected to each Stat device as protection against high voltage transient signals which may occur such as in the event of a lightning strike. 1 PN 3005014 1. Installation Series YELLOW wire to OUTPUT X+ wiring GREEN wire to OUTPUT X- wiring RED wire to Stat -X Initiator BLACK wire to other side of Stat -X Initiator -7 END L ❑F Cr LINE 11 C DEVICE X X X I) vJ vJ Installation Bulletin 3/05/10 Ematch Protective Device 2. Installation End of Line If the Stat -X unit is the last device on an OUTPUT circuit then: YELLOW wire to OUTPUT X+ wiring GREEN wire to OUTPUT X- wiring RED wire to RED wire of the EOL Resistor Diode Assy BLACK wire of the EOL Resistor Diode Assy to Stat -X Initiator BLACK wire to other side of Stat -X Initiator w END L J 1 ❑F LINE I DEVICE X For all UL compliant installations, each Stat -X device must have its own, properly installed, Ematch Protective Device PN 3005014 Installation Bulletin 3/05/10 Ematch Protective Device SYSTEM SENSOR® Photoelectric Smoke Detectors System Sensor i3 M series smoke detectors represent significant advancement in conventional detection. 3 The i family is founded on three principles: installation TM ease, intelligence, and instant inspection. Features Installation ease.The i line redefines installation ease with its Plug-in detector line, mounting base included plug -in design.This allows an installer to pre -wire bases (included with heads).The large wire entry port and in -line terminals provide Large wire entry port ample room for neatly routing the wiring inside the base.The base In -line terminals with SEMS screws accommodates a variety of back box mounting methods as well as Mounts to octagonal and single -gang back boxes, 4- square back direct mounting with drywall anchors.To complete the installation, i boxes, or direct to ceiling heads plug into the base with a simple Stop -Drop 'N Lock'" action. Stop -Drop 'N Lock attachment to base Intelligence. i detectors offer a number of intelligent features Removable detector cover and chamber to simplify testing and maintenance. Drift compensation and Built-in remote maintenance signaling smoothing algorithms are standard with the i line to minimize nuisance alarms. 2 -wire i detectors can generate a remote LED- Drift compensation and smoothing algorithms indicated maintenance signal when connected to the 2W -MOD2 Simplified sensitivity measurement loop test /maintenance module or a panel equipped with the i Wide angle, dual color LED indication protocol. The SENS -RDR, a wireless device, displays the sensitivityof i detectors in terms of percent per -foot obscuration. Loop testing via EZ Walk feature Built -in test switch Instant inspection. The i series provides wide -angle red and green LED indicators for instant inspection of the detector's condition: normal standby, out -of- sensitivity, alarm, or freeze trouble. When connected to the 2W -MOD2 loop test /maintenance module or a panel with the i protocol, the EZ Walk loop test feature is available on 2 -wire i detectors.This feature verifies the initiating loop wiring by providing LED status indication at each detector. Agency Listings 01) MEA MSFM us LISTED APPROVED 1 1 approved approved 5911 3011446 7272- 1653:152 290 -01 -E 2093 3180932 (j Smoke Detector Specifications Architectural /Engineering Specifications Smoke detector shall be a System Sensor i Series model number listed to Underwriters Laboratories UL 268 for Fire Protection Signaling Systems.The detector shall be a photoelectric type (Model 2W -B, 4W -B) or a combination photoelectric/thermal (Model 2WT -B, 4WT-B) with thermal sensor rated at 135"F (57.2 °C). The detector shall include a mounting base for mounting to 31/2cinch and 4 -inch octagonal, single -gang, and 4 -inch square back boxes with a plaster ring, or direct mount to the ceiling using drywall anchors. Wiring connections shall be made by means of SEMS screws.The detector shall allow pre wiring of the base and the head shall be a plug -in type. The detector shall have a nominal sensitivity of 2.5 percent per -foot nominal as measured in the UL smoke box. The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms.The detector shall provide dual color LED indication that blinks to indicate power up, normal standby, out of sensitivity, alarm, and freeze trouble (Model 2WT -B, 4WT-B) conditions. When used in conjunction with the 2W -MOD2 module, 2 -wire models shall include a maintenance signal to indicate the need for maintenance at the alarm control panel and shall provide a loop testing capability to verify the circuit without testing each detector individually. Electrical Specifications Operating Voltage Nominal: 12/24 V non polarized Minimum: 8.5V Maximum: 35 V Maximum Ripple Voltage 30% peak to peak of applied voltage Standby Current 2 -wire: 50 pA maximum average; 4 -wire: 50 pA maximum average Maximum Alarm Current 2 -wire: 130 mA limited by control panel; 4 -wire: 20 mA @12 V, 23 mA 24 V Peak Standby Current 2 -wire: 100 NA; 4 -wire: n/a Alarm Contact Ratings 2 -wire: n /a; 4 -wire: 0.5 A 30 V AC /DC Physical Specifications Dimensions (including base) 5.3 inches (127 mm) diameter; 2.0 inches (51 mm) height Weight 6.3 oz (178 g) Operating Temperature Range 2W -B and 4W -B: 32°F to 120T (0 "C to 49 °C); 2WT -B and 4WT -B: 32 "F to 1007 (0 °C to 37.8°C) Operating Humidity Range 0 to 95% RH non condensing Thermal Sensor 135 °F (57.2 °C) fixed Freeze Trouble 2WT -B and 4VVT-B only: 41 °F (5 °C) Sensitivity 2.5 %/ft nominal Input Terminals 14 to 22 AWG Mounting 31/2-inch octagonal back box 4 -inch octagonal back box Single -gang back box 4 -inch square back box with a plaster ring Direct mount to ceiling LED Modes Power -Up Sequence for LED Indication LED Mode Green LED Red LED Condition Duration Power up Blink every 10 seconds Blink every 10 seconds Initial LED status indication 80 seconds Normal (standby) Blink every 5 seconds off Out of sensitivity off Blink every 5 seconds Freeze trouble off Blink every 10 seconds Alarm off Solid Ordering Information Model Thermal Wiring Alarm Current 2W -B No 2 -wire 130 mA max. limited by control panel 2WT -B Yes 2 -wire 130 mA max. limited by control panel 4W -B No 4 -wire 20 mA 12 V, 23 mA 24 V 4WT -B Yes 4 -wire 20 mA 12 V, 23 mA 24 V Accessories 2W -MOD2 2 -wire loop test maintenance module RT Removal replacement tool SENS -RDR Sensitivity reader A77 -AB2 Retrofit adapter bracket, 6.6 inch (16.76 cm) diameter SYSTEM ©2009 System Sensor. 3825 Ohio Avenue St. Charles, IL 60174 P roductspeaficauonssuot ect M changewithou tnotice.usit syaemsensor.cornfor s SENSOR c u rrent pro information, including the latest version delis data sheet. Phone: 800 SENSOR2 •Fax: 630 377 6495 A05- 0318 -007 6/09.42169 fTh, SYSTEM SENSOR® Selectable- Output N. Horns, Strobes, and Horn Strobes SpectrAlert* Advance selectable- output horns, strobes, and horn strobes are rich with features guaranteed to p�j� cut installation times and maximize profits. SPECTIIC alrALANAmEarlirE Features The SpectrAlert Advance series offers the most versatile and Plug -in design with minimal intrusion into the back box easy -to -use line of horns, strobes, and horn strobes in the industry. With white and red plastic housings, wall and ceiling mounting Tamper- resistant construction options, and plain and FIRE printed devices, SpectrAlert Advance can Automatic selection of 12- or 24 -volt operation at 15 and 15/75 meet virtually any application requirement. candela Field- selectable candela settings on wall and ceiling units: 15, 15/75, Like the entire SpectrAlert Advance product line, horns, strobes, 30, 75, 95, 110, 115, 135, 150, 177, and 185 and horn strobes include a variety of features that increase their Horn rated at 88+ dBA at 16 volts application versatility while simplifying installation. All devices Rotary switch for horn tone and three volume selections feature plug -in designs with minimal intrusion into the back box, which make installations fast and foolproof while virtually Universal mounting plate for wall and ceiling units eliminating costly and time consuming ground faults. Furthermore, Mounting plate shorting spring checks wiring continuity before a universal mounting plate with an onboard shorting spring tests device installation wiring continuity before the device is installed, protecting devices Electrically compatible with existing SpectrAlert products from damage. Compatible with MDL sync module In addition, field selectable candela settings, automatic selection of 12- or 24 -volt operation, and a rotary switch for horn tones with three volume selections enables installers to easily adapt devices to suit a wide range of application requirements. Agency Listings SIGNALING MEA 7125- (ino b LISTED APPROVED approved 7125- 15531851bor dor n st ro str bes, 54011 (chimes. horn strobes, horns) 3023572 MEA452 -05 -E chime strobes) 55512 (strobes) 7135 1653.189 (horns, chimes) SpectrAlert Advance Specifications Architect /Engineer Specifications General SpectrAlert Advance horns, strobes, and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box, 4 -inch octagon back box, or double -gang back box.Two -wire products shall also mount to a single -gang 2 x 4 x 1 -inch back box. A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync•Circuit Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12- volt -rated notification appliance circuit outputs shall operate between 9 and 17.5 volts; 24- volt -rated notification appliance circuit outputs shall operate between 17 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full -wave rectified unfiltered power supply. Strobes and horn strobes shall have field selectable candela settings including 15, 15/75, 30, 75, 95, 1 10, 115, 135, 150, 177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens /reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens /reflector system.The horn shall have three audibility options and an option to switch between a temporal three pattern and a non temporal (continuous) pattern.These options are set by a multiple position switch. On four -wire products, the strobe shall be powered independently of the sounder.The horn on horn strobe models shall operate on a coded or non -coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 4 "/16 x 4 "/16 x 2 -inch back box.The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit.The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical /Electrical Specifications Standard Operating Temperature 32 °F to 120 °F (0 °C to 49 °C) Humidity Range 10 to 93% non condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC /FWR or regulated 24 DC /FWR' Operating Voltage Range 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling -Mount Dimensions (including lens) 6.8 diameter x 2.5 high (173 mm diameter x 64 mm high) Wall -Mount Dimensions (including lens) 5.6 L x 4.7"W x 2.5 D (142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6° L x 4.7"W x 1.3"D (142 mm L x 119 mm W x 33 mm D) Wall -Mount Back Box Skirt Dimensions (BBS -2, BBSW -2) 5.9 L x 5.0"W x 2.2"D (151 mm L x 128 mm W x 56 mm D) Ceiling -Mount Back Box Skirt Dimensions (BBSC -2, BBSCW -2) 7.1 "diameter x 2.2 high (180 mm diameter x 57 mm high) Wall -Mount Trim Ring Dimensions (sold as a 5 pack) (TR- HS,TRW -H5) 5.7 L x 4.8"W x 0.35"D (145 mm L x 122 mm W x 9 mm D) Ceiling -Mount Trim Ring Dimensions (sold as a 5 pack) (TRC -HS, TRCW -HS) 6.9 diameter x 0.35 high (175 mm diameter x 9 mm high) Notes: 1. Full Wave Rectified (FWR) voltage is a non regulated, time varying power source that is used on some power supply and panel outputs. 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. 605 -3395 -007 UL Current Draw Data UL Max. Strobe Current Draw (mA RMS) UL Max. Horn Current Draw (mA RMS) 8 -17.5 Volts 16 -33 Volts 8 -17.5 Volts 16 -33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela Range 15/75 142 148 77 81 Temporal Medium 44 49 58 69 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non temporal High 57 56 69 75 95 NA NA 181 176 Non temporal Medium 42 50 60 69 110 NA NA 202 195 Non temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela Range 150 NA NA 246 220 Coded Low 40 46 52 50 177 NA NA 281 251 185 NA NA 286 258 UL Max. Current Draw (mA RMS), 2 -Wire Horn Strobe, Standard Candela Range (15 -115 cd) 8 -17.5 Volts 16 -33 Volts DClnput 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non Temporal High 142 161 103 112 126 181 203 221 229 Non Temporal Medium 134 155 85 95 110 166 189 208 216 Non Temporal Low 132 154 80 90 105 161 184 202 211 UL Max. Current Draw (mA RMS), 2 -Wire HornStrobe, High Candela Range (135 -185 cd) 16 -33 Volts 16 -33 Volts DClnput 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non Temporal High 255 270 303 309 Non Temporal High 233 248 275 281 Non Temporal Medium 242 259 293 299 Non Temporal Medium 219 232 262 267 Non Temporal Low 238 254 291 295 Non Temporal Low 214 229 256 262 Horn Tones and Sound Output Data Horn and Horn Strobe Output (dBA) 8 -17.5 16 -33 24 -Volt Nominal Switch Volts Volts Reverberant Anechoic Position Sound Pattern dB DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non Temporal High 82 82 88 88 93 92 100 100 5 Non Temporal Medium 78 78 85 85 90 90 98 98 6 Non Temporal Low 75 75 81 81 88 84 96 92 7t Coded High 82 82 88 88 93 92 101 101 8t Coded Medium 78 78 85 85 90 90 97 98 9t Coded Low 75 75 81 81 88 85 96 92 tSettings 7, 8, and 9 are not available on 2 -wire horn strobe. A05 -0395 -007 SpectrAlert Advance Dimensions F-4.7" 2.5" 6.8" Dia. �l ^ll iii Wall -mount horn strobes Ceiling -mount horn strobes 7.1- 1-2.25 1 r 5.05" 2.23+1 Dia. I I I I 4 o\ t 5.98 o I ii Wall back box skirt Ceiling back box skirt SpectrAlert Advance Ordering Information Model Description Model Description Wall Horn Strobes Ceiling Strobes P2R *t 2 -Wire Horn Strobe, Standard cdt, Red SCR Strobe, Standard cd, Red P2RH* 2 -Wire Horn Strobe, High cd, Red SCRH Strobe, High cd, Red P2W* 2 -Wire Horn Strobe, Standard cd, White SCW* Strobe, Standard cd, White P2WH* 2 -Wire Horn Strobe, High cd, White SCWH Strobe, High cd, White P4R* 4 -Wire Horn Strobe, Standard cd, Red Horns P4RH 4 -Wire Horn Strobe, High cd, Red HR Horn, Red P4W 4 -Wire Horn Strobe, Standard cd, White HW Horn, White Wall Strobes Accessories SR *t Strobe, Standard cd, Red BBS -2 Back Box Skirt, Wall, Red SRH *t Strobe, High cd, Red BBSW -2 Back Box Skirt, Wall, White SW* Strobe, Standard cd, White BBSC -2 Back Box Skirt, Ceiling, Red SWH* Strobe, High cd, White BBSCW -2 Back Box Skirt, Ceiling, White Ceiling Horn Strobes TR -HS Trim Ring, Wall, Red PC2R* 2 -Wire Horn Strobe, Standard cd, Red TRW -HS Trim Ring, Wall White PC2RH 2 -Wire Horn Strobe, High cd, Red TRC -HS Trim Ring, Ceiling, Red PC2W *t 2 -Wire Horn Strobe, Standard cd, White TRCW -HS Trim Ring, Ceiling, White PC2WH' 2 -Wire Horn Strobe, High cd, White PC4R 4 -Wire Horn Strobe, Standard cd, Red PC4RH 4 -Wire Horn Strobe, High cd, Red PC4W 4 -Wire Horn Strobe, Standard cd, White Notes: "Add -P "to model number for plain housing (no "FIRE "marking on cover), e.g., P2R -P. Add -SP "to model number for "FUEGO "marking on cover, e.g., P2R -5P. "Standard cd" refers to strobes that include 15, 15/75, 30, 75, 95, 110, and 115 candela settings. "High cd "refers to strobes that include 135, 150, 177, and 185 candela settings. SYSTEM ®2009 System Sensor. 3825 Ohio Avenue St. Charles, IL 60174 Product speciriauons subject change without notice Visit systemsensorcom for SENSOR® Phone: 800- SENSOR2 Fax: 630-377-6495 current product information. including the latest version of this data sheet. A05- 0395 -007 •4/09 •,',2132 RCDS -1 p P R RELEASING CIRCUIT The Symbol of Protection DISABLE SWITCH UL recognized components Dimensions: 2 3/4" W x 4 -1/2" H x 2" D (Approximate) Mounts on single gang or handy box Contact Rating: 40 VDC Power Requirements: 24 VDC Environmental Specifications: Indoor use only Temperature range -22 °F to 140 °F -30 °C to 60 °C) 1 Stock number: 3001002 Description The device consists of a stainless steel faceplate and switch assembly. It is designed to mount on a standard single gang electrical enclosure. Application The RCDS -1 complies with the requirements of NFPA 72, 2007, 6.12.5, 6.12.5.1, and 6.12.5.2: Specifying a physical switch to disconnect the release circuit in place of a software controlled disconnect. Creating a supervisory condition on the associated release panel. Installation and Operation 1. Connect the red and black leads to the 24 VDC auxiliary power terminals on the release panel. Be certain to observe polarity. 2. Connect the yellow wires to the supervisory zone on the panel. NOTICE The connection for the supervisory circuit has 4 wires: 2 yellow and 2 grey. The 2 yellow wires are for connection to the supervisory circuit. The 2 grey wires are for connection to additional supervisory devices or the EOLR for the supervisory zone. 24 VDC SUPERVISORY RELEASING ZONE CIRCUIT Q RED 0 LED'S Q YELLOW O YELLOW ORANGE KEY SWITCH ORANGE BLACK RED O EOL GRAY DIODE ASSY RELEASING DWG# 214 -1 RAY SOLENOID Potter Electric Signal Company, LLC St. Louis, MO Phone: 866 956 0988 /Canada 888 882 -1833 www.pottersignal.com PRINTED IN USA MKT. #5401214 REV B PAGE 1 OF 1 6/09 B TI Universal utto n FEATURES Momentary button offers many options to provide just what a customer wants in one convenient package. Faceplate constructed of cast aluminum. 0 us Illuminated 12/24 volt LED button and illuminated message light kit. UB Two sets of independent Form "C" contacts. Contacts rated at 10A, 1/2 HP, 125/250 VAC, 6A, 30V. Temperature: -40° to 185° F -40° to 85 °C). PRODUCT OVERVIEW UL Listed to U.S. and Canadian safety This momentary button helps eliminate having to stock dozens of push buttons, and standards. wasting precious time and money tracking down just the right button for a customer. It 100,000 operations. Mounts to standard electrical handi offers many options to provide just what a customer wants in one convenient package. box. Button is ready to be assembled out of box and is easily installed within minutes on site. Offers 240 different combinations. Universal Button offers an astounding 240 different combinations for the price of a Single ld plate to installation ta llatio oversized to g p cover old plate installation marks. standard one configuration button. The faceplate is constructed of cast aluminum metal, Five inserts for the button included allowing it to take tough knocks in stride, and is slightly oversized to cover old plate EXIT, PUSH, PUSH TO EXIT, handicap installation marks. Button package includes: faceplate, three illuminated push buttons, symbol and blank. five changeable button messages and ten changeable illuminated activation messages. red, Three different lens covers included 9 g 9 g red, green and blue. Ten color coated message inserts in HOW IT WORKS green, blue, yellow and white. The installer simply has to choose which lens cover, button insert and interchangeable Plate messages inscribed with EXIT, message plate works best for the customers need, and easily snap them in place. This EMERGENCY and translucent blanks (allowing for custom labels). allows the button to be mounted in a matter of minutes instead of waiting weeks for a One year guarantee on electro specific button to be ordered and delivered. mechanical and electronic components. Safety Technology For more information, call 1-800-888-4784 (4STI) or visit www.sti- usa.com International, Inc. STI Universal Button Dimensions and Technical Information MODEL AVAILABLE APPROVALS WARRANTY UB -1 Universal Button TESTING UB -2 2" Universal Button It has been tested and approved or listed by: UL /cUL File S7255, Volume 2 WARRANTY Accessories One year guarantee on electro mechanical and electronic LT -1 Latching /Timer Module components. UB -2LENS 2" Lens UB -1CL -Color Custom Label applied to blank, changeable message plates (blue, green, white or yellow plate) SUB -UB -1C Contact Block SUB- 71102A -COLOR Color Match Backbox Kit (red, blue, green, white or yellow) 10147 24 Volt LED, White (standard) 10145 24 Volt LED, Red 10141 24 Volt LED, Blue 10143 24 Volt LED, Green 10144 12 Volt LED, Red 10140 12 Volt LED, Blue 10142 12 Volt LED, Green STI -6518 Bopper Stopper Protective Cover STI- 6600 -COLOR Mini Stopper® II with Horn (blue, green, white or yellow) REAR VIEW FRONT VIEW ALIGN TAB ON ACTUATOR WITH SLOT BUTTON. UB-2 I�M I� TURN CLOCKWISE TO LOCK. No, 1 ---..4g6-1) 61,ii(1(■ INSERT ASSEMBLY WITH SPRING INTO PLATE. Ingo ‘,-im „.0I� JA i PLATE SPRING ACTUATOR CAP ACTUATOR 2 in. BUTTON UB-1 e ED 4. 830 in. I, (123mm) AI III ire, l 3.220 in. (82mm) .867 in. 1.328 in. (22mm) (34mm) 2306 Airport Road Tel: 248-673-9898 Unit 49G Pipers Road Tel: 44 (0) 1527 520 999 CD Safety Technology Waterford, Michigan Fax: 248 673 -1246 Park Farm Industrial Estate Fax: 44 (0) 1527 501 999 International, Inc. 48327, USA Tollfree: 800- 888 -4784 Redditch, Worcestershire Free: 0800 085 1678 (OK) info©sti- usa.com 898 OHU England www.sti-europe.com www.sti usa.com Printed in U.S.A., 2007 2009 Safety Technology International, Inc. 06/09 SPECTRUM Series Special A Manual Alarm Stations Features The SPECTRUM Series is a family of die -cast, metal pull stations designed to meet special application requirements such as: weather alert, hazmat spills, police call, medical emergencies, door release and fire suppression. Single or Dual Action There is a series of special application labels to designate the function of the pull station for the user. There is no agency standard, outside of red for Special Applications Labeling fire that dictates what color is to be used for a specific application. (see inside page) This series of pull stations is available as either SG -32CXK micro switch or SG -42CXK toggle switch versions, in single or dual action configurations. There are two sets of gold plated contacts that can be configured by the Screw Terminal Connections installer as either normally open or normally closed, depending on how the switch wires are connected to the terminal block which also accommodates Normally Open or Closed the field wiring #22 to 14 AWG). All models have been tested by UL and found in compliance with the pull force requirements of the Americans with Alarm /Auxiliary Contacts Disabilities Act (ADA). SG- 32/42CXK stations are key resettable. Gold Plated Contacts The stations are operated by pulling the handle marked "PULL" on the front of the unit as far down as it will go. At that point, the handle will Surface or Weatherproof Back-box lock in place and is easily visible from up to 50 feet. The activation handle is reset by opening the station with the key, placing the "PULL" Deeper back -box available to provide handle to its normal upright position (resetting the toggle switch when applicable) and relocking the station. On the dual action, the "PUSH" or more space for wire andlor address optional "EMERGENCY" bar moves inward allowing the "PULL" handle to be operated by a single hand. able module Consult factory for other colors Semi Flush -All models mount on a standard single -gang back -box. Surface Mount Interior -Use SigCom SGB -32S or the deeper metal back box (SGB- 32SD). Surface Mount Exterior- -Use SigCom SGB -32C (SG -WP) or the deeper die -cast, weatherproof back -box (SGB -32CD) SIG COM j j 1 MEA C us 4 Sinal Communications Cor oration P LISTED t APPROVED SPEC060908 Listings: UL, ULc, FM, CSFM, MEA Temperature: -40° to 150 °F, 90% relative humidity 100 °F Switch Rating: SG -32 Micro switch 1 Amp 30 VDC, lAmp 125 VAC SG -42 Toggle switch 2 Amps 125 VDC, 2 Amps 240 VAC Pull Station Weight: 1.2 lbs Pull Station Dimensions: 4 3/4 "h x 3 1 /4 "w x 1.1 "d Surface -Mount Backbox Dimensions: 4 3/4 "h x 3 1 /4 "w x 2 1 /4 "d (outside); 2 1 /8 "d (inside) cast and sheet metal Deep Surface -Mount Backbox Dimensions: 4 3/4 "h x 3 1 /4 "w x 2 3/4 "d (outside); 2 5/8 "d (inside) cast and sheet metal Color: Red, Blue, Yellow or Green with indented spaces to apply special application labels and white "PULL" (single action) or "PUSH" bar (dual action) with raised red letters Standard Manual Alarm Station: SG- CXK 3 Micro Switch 4 Toggle Switch GR Green YL Yellow 2 Standard pull station BL Blue 6 "EMERGENCY" push bar in place of "PUSH" bar RD Red 1 Dual action 2 Single action Standard Manual Alarm Station Surface Backbox: SGB -32 S Interior, surface mount, sheet metal backbox with 3/4" knockouts GR Green YL Yellow C Weatherproof, surface mount, die -cast metal backbox BL Blue with one tapped hole for 3/4" NPT fitting (same as SG -WP, meets NEMA 3R) RD Red SD Deep Interior, surface mount, sheet metal backbox with 3/4" knockouts CD Deep Weatherproof, surface mount, die -cast metal backbox with one tapped hole for 3/4" NPT fitting. Meets NEMA 3R Accessories: SG -GRO1 12 pack of scored, plastic (acrylic) break -rods for spares or replacement SG -PBK PUSH bar kit SG -PBEK Push bar EMERGENCY kit 890 -1683 Gasket for SG -WP replacement SIG For red, New York City listed fire alarm stations, see NYC Station data sheet. COM Signal Communications Corporation P.O. Box 2588 Woburn, MA 01888 Tel.: 781 933 0998 Fax.:781 933 5019 SPEC060908 www.sigcom.com =OM Manual Alarm Station Labels Description Part Number Blue (white Yellow (red Green (white text) text) text) ALERT ALERT 880 0047 X X X Top Labels OPEN DOOR 880 0050 X X (2 label set) ALARM ALARM 880-0046-* X X X LOCAL EVAC 880 0048 -Y X AFFF RELEASE 880 0053 -Y X EMERGENCY 880 -0055= X X MEDICAL 880 0056 X X X TORNADO 880 0057 X X EVACUATE 880 0054 -Y X Bottom Label DOOR RELEASE 880-0058-* X X HAZMAT 880 -0052Y X POLICE 880- 0062 -B X MANUAL RELEASE 880 -0101 X SUPPRESSION RELEASE EXTINGUISHER RELEASE SPRINKLER RELEASE Note: The vinyl labels are shipped at no charge if placed on the order with the pull stations, with the exception of part number 880-0101, call customer service. Please indicate color request on your order. Y Yellow; B Blue, G Green SIG COM Signal Communications Corporation P.O. Box 2588 Woburn, MA 01888 Tel.: 781 933 0998 Fax.:781 933 5019 SPECO60908 www.sigcom.com The Spectrum series manual pull stations (SG- _CXK_) has a pair of r ".1 switches that can be connected either as a Normally Open (N.O.) R W switch, that closes when the lever is pulled; or as a Normally Closed (N.C.) switch that opens upon activation. The switches are mechani- cally connected, but electrically isolated allowing them to initiate alarms in two different systems or using one contact for alarm reporting and the other for an auxiliary function, such as: door r release, door open or local annunciation. p o i a Example: Using one side as a Normally Open switch for a FIRE Alarm connection, while the second is connected to a Normally Spectrum Series Closed loop on a security alarm panel. Two Form 'A' Or' 'B' Switches N -O. or N.C. contacts u r» Ham a. a, 1 c. onto. shook Wm) r or N.C. Mod VJ curb da TM S RY Description Model Backplate Kit ST -BKPO1 Extender Kit ST -XTRO1 Weatherproof Kit ST WPK01 Front Cover Kit ST -FRCO1 Alarm Module Kit ST ALMO1 Front Carr wrarwti ,f t Vii-. i 3 a ►Ysd+iM M o l: Pal J 11l f' For more information, see Sentry data sheet. SIG COM Signal Communications Corporation www.sigcom.com sPeco6o9os www.si g P.O. Box 2588 Woburn, MA 01888 Tel.: 781 933 0998 Fax.:781 933 5019 Size: 4" x 6" THIS AREA IS PROTECTED BY AN Sta t-X® FIRE SUPPRESSION SYSTEM DO NOT ENTER UNLESS THE FIRE SUPRESSION SYSTEM IS DISENGAGED DO NOT ENTER AFTER DISCHARGE UNTIL AREA HAS BEEN THOROUGHLY VENTILATED Size: 3.5" x 3.5" Approx Sta t-X® SYSTEM ISOLATE SWITCH 1. PLACE KEY-SWITCH IN "OFF" POSITION PRIOR TO ENTERING AREA 2. RETURN KEY-SWITCH TO "ENGAGED" POSITION WHEN LEAVING THE AREA 3. ENSURE THE AREA IS CLEAR OF PERSONNEL BEFORE RE-ACTIVATING THE SYSTEM Size: 4" x 6" or 6" x 8" approx THIS AREA IS PROTECTED BY AN Sta t -X FIRE SUPPRESSION SYSTEM EVACUATE AREA ON SOUND OF ALARM DO NOT ENTER AFTER DISCHARGE UNTIL AREA HAS BEEN THOROUGHLY VENTILATED Size: 4" x 2.5' approx Sta t -X® FIRE SUPPRESSION SYSTEM MANUAL PULL STATION ENSURE AREA IS EVACUA TED BEFORE RELEASE OF SYSTEM