HomeMy WebLinkAbout2140 Bldg 1030 W 18th St - Technical j Permit I I- I o' Address 21 o w I'6 i o 5o Project description spray boo-rh Date the permit was finaled 0 2 3 1'x' Number of technical pages I frideliS77, NES" 4 ,,gip MANUFACTURERS OF HEATING, VENTILATING, HEAT RECOVERY AIR CONDITIONING PRODUCTS SUBMITTAL DATA Job Name: ANGELES COMPOSITE TECHNOLOGIES, INC. Location: PORT ANGELES, WA Sales Representative: HASTINGS HVAC, INC. Submitted by: HASTINGS HVAC, INC. Date: REVISED 8/6/2011 Requisition Number: R# 61096, 61097 Approved by: Date: Hastings HVAC, Inc. 3606 Yost Avenue Hastings, Nebraska 68901 -1966 Ph. (402) 463 -9821 Fax (402) 462 -8006 EQUIPMENT SCHEDULE R #61096 1 LU- 218 -20 -1643 HASTINGS MODEL LU- 218 -20 -1643 DIRECT FIRED MAKE -UP AIR SYSTEM TO DELIVER 20,000 CFM AT 1.5' W.C. TOTAL STATIC PRESSURE LP GAS FIRED AT 11" INLET PRESSURE AND 1643 MBH N INPUT 1 LU -218 1 (VUR -2) VERTICAL UP SIDEFLOW ARRANGEMENT 1 WEATHERPROOF UNIT 1 BIRDSCREEN VUR UNITS 1 V -BANK FILTER SECTION (LESS FILTERS) 1 2" 30% EFFICIENT PLEATED FILTERS 1 MOTORIZED DISCHARGE AIR DAMPER OUTDOOR 1 AUXILIARY STARTER CONTACT 1 ULTRA- VIOLET FLAME SENSOR 1 OMIT REM CONTROL STAT W /SWITCHES LITES 1 UL LABELED MAIN PANEL 1 15 HP 460V 3PH 1SPD ODP MTR STR 1 VARIABLE PITCH SHEAVE 1 FUSED DISCONNECT SWITCH 1 PROPANE FIRING PRIMARY FUEL 6 OZ -1 PSIG 1 GAS PILOT IGNITION 1 UPGRADE MAIN DISCONNECT FOR (1) 10 HP EXHAUST MOTOR 1 600V TERMINAL STRIP WITH 35 AMP TYPE J FUSING 1 TD94E -0409 A1494 TEMP. CONTROLLER BY ROHNER 1 TS -194 DISCHARGE SENSOR PROVIDED AND INSTALLED BY HASTINGS 1 RMI GREY TEXTURED FINISH 1 NO HASTINGS LOGO OR LABELS 1 n z c N co El A co n m m o 6 n //9 5 rn F O N 1 I N. co A Z N 1 (i rn t i I I I A k I A 1 1 w 1 m Z coop O J J 1 I Z m O 0 nmm co 1 N zz .Z1 m XI ZZ rnmu) 1 i -n o� I °O I m Mm2 ci� o N O 0O N z I sc o Nxi O; N V Z A M O D A J O O T. mz� Oa m m AD m O CO v O D O MI n O 0 Z n° O v n A c s. 73 mn Arn z m c W n M Z O O .<XI; O y S N zM cX m oz co VI i m m Z 0 0 r 0 0 C N D r m° z z r ru 2 N N N co W c- v N o r I I II I T C C I I I h- c N A I I 1� 1 I1 Z i_ -H I I N W p v I I O m 0 m II 1 m I p m 1 �J D o m k___ I 11 I 11 n m I I I I m I 11 Z A 1 I I L M \I N 0 11 io xi cD D m D p rn m z x; o m z N w I. 0 r Im 0 N 0 0 4111 4 p8 C I I r J Lj u u 4DA FURNISHED INSTALLED BY OTHERS FURNISHED BY FACTORY INSTALLED BY OTHERS FACTORY FURNISHED INSTALLED ITEM DESCRIPTI ❑N 1 MAIN GAS HAND SHUT -OFF VALVE (IF REC❑MMENED BY FM) X 2 DRIP LEG X 3 MAIN GAS HAND SHUT -OFF VALVE NPT X 4 SAFETY SHUT -OFF VALVE WITH PROOF OF CLOSURE X 5 SELECTRA VALVE X 3_ 1. f 2 �M 6 HIGH GAS PRESSURE SWITCH (IF RECOMMENDED BY FM) X 7 MANUAL LEAK TEST HAND VALVE X 8 MAIN GAS BURNER X 9 PILOT GAS BURNER X 10 TEST CONNECTION UPSTREAM OF ITEM 4 X 11 TEST CONNECTI ❑N DOWNSTREAM OF ITEM 5 X 12 PIL ❑T GAS SUPPLY LINE X 13 PIL ❑T GAS HAND VALVE X 14 PIL ❑T PRESSURE REGULATOR X 15 PIL ❑T S❑LENI ❑D VALVE X 16 PILOT NEEDLE VALVE (IF REQUIRED) X 17 18 INDOOR UNITS MAY REQUIRE VENTING OF SOME COMPONENTS, FURNISHED BY OTHERS, VENTING LINES MAY NOT BE SHOWN IN SOME CASES. A TEST C❑NNECTI ❑N CAN BE AN INTEGRATED PORT ON A COMPONENT OR A SEPARATE PIPING TEE 861096 vA Y 10 2 u 1 CK'D BY DATE CHGU BY DATE REV Lit ILR REVISION DR. BY JJC PART NUMBER DATE 11/5/04 MANIFOLD W /ELECTRIC MODULATION Hastings MATERIAL QUANTITY HVAC, INC. M252 111 100 1 FD 0-1I"0 1M 101 I F1 I131 BLK o BLK lo BLK 0 11-00C/0 BU( 102 -o I I BU< BLK go BLK 0 II-0fX•0 BLK 103 I BLK BLK BLK O I1-0/Xi0 EU< oil 104 --O 111. EG 105 TO 3 PHASE POWER SUPPLY AND LOW IMPEDANCE (5 10) 108 EARTH GROUND BLK BLK 107 F4 -4► T O EXHAUST 108 FS MOTOR 109 F F BY OTHERS 7 8 F6 (10 HP 460/3) 110 'v CLASS J FUSES BLK BLK 111 I I 112 I T2 113 114 BLK cl I F9 I p RED I 11 5I IWHT EG GI 115 A BL 118 0- --pip_ 4 BLK VAIT© 117 HL I— REO RED T1 118 4 119 BLU BLU 1 1 YEL 120 YEL .2R2• Y EL YEL BLK OZ TS194Q 121 i r v R I 122 I BLK 2 T' Q' 1 r 123 F r Q I I 1 0 A r1t 1 11 12 10 11 VL r 1I l (l 11 TD94E -0409 124 T 6(5®®® /I'�< I 125 T SA I A1494 128 L -I<> 127 128 *EFl PROVING BLU 1M OL 129 r O- 11-0 O B BLU .OVA-IT Q 137 130 I I 131 L EXHAUST M2 1 ENABLE 132 *DP 133 O RED LK BLU :LK .0:W1T 153 134 BLK BLK 135 Q *DM WIT 1NFIT 133 2 SUMMER 137 138 O PRP 0 111 PRP. 8 U *AP-L O -04-�0- OFF I• t38 2R1 0- WINTER 139 140 OR •LU MV-ES *AT BLU H BLU O J PRP 2R T© 139 it> 141 PR (FIREYE) *MV 142 ORG U ICI_ PRP 13 PRP WHT© 140 143 MEP104 144 BLU o 1� 8LK BLK BLK *PV BLK WHTQ 145 Ll 148 O7 8LK In L� R_ BRN ®BRN *GN MT. 147 V 148 I I EE Eh MT WHTO 149 150 13 151 BLK BLK AT p WHT WHT 1 C014 140 SENSOR 153 152 1 2 BLK PRP i 3R1 PRP 4 1> c 8LK T E 154 EXHAUST ENABLE 155 DESIGNATES COMPONENTS EXTERNAL TO MASTER CONTROL PANEL. PRP 4 REFER TO "RATINGS OF EXTERNAL LOADS TO CONTROL PANEL" SHEET 156 FOR RATINGS OF EXTERNAL LOADS. DISK 5/16/11 A ADD UL LABEL MAIN CONTROL PANEL RR v 1 ,'.:3 MAY 2O 0 dC0 BY I DAZE I ac'o By DAZE REV L1R RENg«, MEW Nom N HAS t i ri DRN. D8K WIRING DIAGRAM: PMT IAAtBD1 AND GENERAL NOTES OAIE 5 SBDCS)- ADGIlIOS6VU1 E11159 HVAC. INC. MAIN CONTROL PANEL 10X36 0 a O El A: a o r� r 7ti■ a❑❑❑❑� 4T PR I I I I' tilt I 60A FD fi=r M f I I I r OM I :II:I II�III�III II �3, E2 lFI Q 71 MOW o. 0 HASTINGS "HVAC INC. 10/29/10 SEQUENCE OF OPERATION 6 SEI 1094 REV 11/16/10 I. SUMMER OPERATION A. SWITCHING THE BLOWER SWITCH TO "061" THE EXHAUST FAN IS ENABLED, THE DAMPER IS OPEN AND THE BLOWER MOTOR OPERATES. B. SWITCHING THE BLOWER SWITCH TO "OFF" WILL STOP THE EXHAUST FAN, BLOWER, AND THE DAMPER IS CLOSED. II. WINTER OPERATION A. THE EXHAUST FAN, BLOWER, AND DAMPER OPERATION IS THE SAME AS DESCRIBED FOR SUMMER OPERATION. B. W ITI1 THE SEASON SWITCH IN THE "WINTER" POSITION, AND THE ENTERING AIR CONTROLLER (AT) CALLS FOR HEAT THE BURNER IS ENABLED. C. THE DIRECT FIRED BURNER IS OPERATING AND THE DISCHARGE TEMPERATURE IS MAINTAINED VIA TFIE DISCHARGE TEMPERATURE SELECTOR CONTROL SETTING. D. IF THE PROTECTORELAY (PR) LOCKS OUT DUE TO FLAME FAILURE, THE "ALARM" LED WILL BLINK ON THE PROTECTORELAY (PR) AND THE BURNER OPERATION IS INACTIVE. IT MUST BE REACTIVATED BY PUSHING THE RESET BUTTON ON THE PROTECTORELAY (PR) WHILE THE POWER TO THE PROTECTORELAY IS ON BEFORE BURNER OPERATION CAN BE RESTORED. 2 is 0 0 0P0 BY I DATE 070'0 VI DALE REV 116 RENSIOR SEE LEGEND NOTE RUBBERS TIER s t i rigs DAN. DBK CONTROL PANEL LAYOUT SEQUENCE MIT NUYlER AND GENERAL NOTES. DALE 5/12/11 SBD(S)— ADGIIIOS6V CP11159 HVA( I NC, EQUIPMENT SCHEDULE R #61097 1 LU- 215 -12 -704 HASTINGS MODEL LU- 215 -12 -704 DIRECT FIRED MAKE -UP AIR SYSTEM TO DELIVER 12,000 CFM AT 1.5" W.C. TOTAL STATIC PRESSURE LP GAS FIRED AT 11" INLET PRESSURE AND 704 MBH INPUT 1 LU -215 1 HR -1 HORIZONTAL FLOW ARRANGEMENT 1 BIRDSCREEN, NO FILTER SECTION FOR ETL 1 AUXILIARY STARTER CONTACT 1 ULTRA- VIOLET FLAME SENSOR 1 OMIT REM CONTROL STAT W /SWITCHES LITES 1 UL LABELED MAIN PANEL 1 10 HP 460V 3PH 1SPD ODP MTR STR 1 VARIABLE PITCH SHEAVE (STD) 1 FUSED DISCONNECT SWITCH 1 PROPANE FIRING PRIMARY FUEL 6 OZ -1 PSIG 1 GAS PILOT IGNITION 1 UPGRADE MAIN DICONNECT FOR ADDITIONAL (1) 3/4 HP EXHAUST FANS 1 (1) 3/4 HP EXHAUST MOTOR STARTERS WITH OVERLOADS AND AUX. CONTACT MOUNTED IN CONTROL PANEL 1 RMI TEXTURED GRAY EXTERIOR FINISH 1 NO HASTINGS LOGOS OR DECALS 1 REMOTE STATION BY RMI WITH MAXITROL TD -94 TEMP. SELECTOR (60 160 DEG. F.), A149 1 160 DEG. MAX. DISCHARGE TEMP 3 a I N 1 W N N 0 r O '7 Zw —I 8 `l 0\ [I z r H a m 2 Z N 1 L- 1— _L -I r m c I i X M g 1 hr iQ 1 I WII 11L All I16 1 �.'io E JL -J4 �L -Jy 3 O� O A z v A N I' z N ^z 01 I r, CO CO m 0 C N Z., O; O: C N 0 r 0 f) z 2 D N D m r 9 (4 0 0 C ..t. Z �I N V7 D N n Z r Iw N N Z Z v/ N z N O O O L woo O Z o m C O 0 zz N E I m Mi N z T T mDt m S 0) N D T HI I C 0 2 m Mv v I D i UIOG m m D D Cz� O m OD -1 r a mz� m 1213zr:><:>z> r�z T1 '�O M D 0 m M m o A O D -1 M O O AZO m z cn 1 10 CO Y `..x I A 1111 tea 1– 0 10 N) 1m 0 00 0 411 4:) (lik 11 LJ u u ®A 0 (i) (r) n J FURNISHED INSTALLED BY OTHERS FURNISHED BY FACTORY INSTALLED BY OTHERS FACTORY FURNISHED INSTALLED ITEM DESCRIPTION 1 MAIN GAS HAND SHUT OFF VALVE (IF RECOMMENED BY FM) X 2 DRIP LEG X 3 MAIN GAS HAND SHUT -OFF VALVE NPT X 4 MAIN GAS PRESSURE REGULATOR X 5 VENT LINE THRU ROOF TO OUTSIDE ATMOSPHERE X 6 SAFETY SHUT -OFF VALVE W/ PROOF OF CLOSURE X 7 SELECTRA VALVE X I° 8 HIGH GAS PRESSURE SWITCH (IF RECOMMENDED BY FM) X 9 MANUAL LEAK TEST HAND VALVE X 10 MAIN GAS BURNER X 11 PILOT GAS BURNER X 12 TEST CONNECTION UPSTREAM OF ITEM 4 X 13 TEST CONNECTION DOWNSTREAM OF ITEM 7 X 14 PILOT GAS SUPPLY LINE X 15 PILOT GAS HAND VALVE X 16 PIL ❑T PRESSURE REGULATOR X 17 PIL ❑T S❑LENIOD VALVE X 18 PIL ❑T NEEDLE VALVE (IF REQUIRED) X INDOOR UNITS MAY REQUIRE VENTING OF SOME COMPONENTS, FURNISHED BY OTHERS, VENTING LINES MAY NOT 9E SHOWN IN SOME CASES. A\ TEST CONNECTION CAN BE AN INTEGRATED PORT ON A COMPONENT OR A SEPARATE PIPING TEE MAY 10, 2011 CK'D BY DATE CHG'D BY DATE REV LLtt t REVISION DR. BY JJC PART NUMBER DATE 11/8/04 MANIFOLD W /ELECTRIC MODULATION Hastings MATERIAL QUANTITY HVAC, INC. M 26 9 1M1 100 1 FD OH I-0 0 101 I F1 I 13 t BLK BLK EIW BLK 0 11 BLK 102 —I -0 I IF2IIL2 BLK BLK 8LK BLK 0 11 0 BLK 0 103 o I F3 I L,L3 BLK BLK BLK BLK 0 I 1-0'X./0 BLK 104 0 -111. EG ELK BLK 2M1 0H1"0 0 105 TO 3 PHASE POWER SUPPLY AND LOW IMPEDANCE (5 1 o) F F 3 11 417 7 1 119-%-11-0/DC/0- Q2 106 EARTH GROUND 7 8 1 EF 107 BLit T.L. 7 LI 1- -00C/0- 108 1 1 (3/4 HP /460/3) 109 T2 111 110 11 881-1( <I F9 I b RED I 1 WHT EG WHT N 112 113 114 115 118 117 118 BL 8LK B T 3 WIT WHT 120 HL 119 o- ----0— V R R T1 121 M_/2 122 BLU B U 1$_ 123 DZ TS194Q 124 O a_ 2R2 R I 125 Ra O I I _8LK rT' 126 F Q I I 127 10 1" o --10/c/6)®®®@(5666111-<< 1 99 1 128 *SA I A1494 129 L -C e 130 v 131 ALL 9.4 OL'S 132 YEL YEL 0„1 1 YEL O T 138 133 ALL 2M OL'S tM O O BRN BRN o 1{, 0 RED .4D. T 132 135 138 2 137 1 O PRP 0 1 1. PRP. BLU S. O BURNER -fl- o--BLE 139 140 BLU o 1 8l I *AP-H I 141 0RG it 81U pV,EQ BLU BLU BLU O -J PRP .0 WHTQ 124 142 PR (FIREYE) MV 143 ORG 0 ET_ PRP t 2 PRP MT. 141 144 MEP 104 PV 145 BLU la 1� BLK 8LK BLK BLK 146 L 147 BLK O BRN B RN WHT© 148 UV 149 1 I liE o- WHT WIT 150 151 13 DESIGNATES COMPONENTS EXTERNAL TO MASTER CONTROL PANEL. 152 REFER TO "RATINGS OF EXTERNAL LOADS TO CONTROL PANEL" SHEET 153 FOR RATINGS OF EXTERNAL LOADS. 154 155 013K 6/8/11 E REMOVE *FROM FD 08K 6/23/10 D RELOCATE 2R2, ADD D TERM, RELABEL TERMS 158 DEW 6/14/10 C ADD TERMINAL 8, RELABEL TERMS P i G 9'7 UK 6/9/10 B REMOVE AT, SW. 3R, at 3R1; RELABEL TERMS .iEV JUNV 1;, 08K 6/7/10 A REMOVED OM DP, RELABEL TERMINALS 0 Oro BY I DAZE CMG'D BYJ DAZE REV OR REMSIDN SEE LEGEND NOTE NUMBERS Has ti zags 11rot DB K WIRING DIAGRAM: PART MAUR MIS GENERAL R01ES OAIE 6 SBD(S)- ADG1tIQS6UIV E11023. HVAC. INC. MAIN CONTROL PANEL 10x36MUA 0 MIS 0 'I- 0 FB h f6 rs P4 am IN PR IBRI g I ■II ■I e e e e I II I IfO07 ha vo re n C., 0» 0 N111 iTe re re e e e HASTINGS "HVAC INC. 6/3/10 SEQUENCE OF OPERATION 6 SE 11023 1. SUMMER OPERATION A. SWITCHING THE BLOWER SWITCH (BL) TO "ON" STARTS THE EXHAUST FAN, WHEN EXHAUST FAN PROVES THE BLOWER MOTOR OPERATES. B. SWITCHING THE BLOWER SWITCH TO "OFF" WILL STOP THE BLOWER AND THE EXHAUSTS FAN. IL WINTER OPERATION A. BLOWER AND EXHAUST FAN OPERATION IS THE SAME AS DESCRIBED FOR SUMMER OPERATION. B. WITH THE "BURNER ENABLE" CONTACT CLOSED THE BURNER IS ENABLED. C. TIIE DIRECT FIRED BURNER IS OPERATING AND THE DISCHARGE TEMPERATURE IS MAINTAINED VIA TIIE DISCHARGE TEMPERATURE SELECTOR SETTING. D. IF THE PROTECTORELAY (PR) LOCKS OUT DUE TO FLAME FAILURE, THE "ALARM" LED WILL BLINK ON THE PROTECTORELAY (PR) TIIE BURNER OPERATION IS INACTIVE. IT MUST BE REACTIVATED BY PUSHING TIIE RESET BUTTON ON THE PROTECTORELAY (PR) WHILE THE POWER TO THE PROTECTORELAY (PR) IS ON BEFORE BURNER OPERATION CAN BE RESTORED. MA '1' :L 201:1. D8K 6/9/10 8 CHNGD SEQ., REAM 3R DBK 6/7/10 A ADD F7, F8, F9. 0 0 c X0 BY I DALE O O'D BY I DALE REV LIR REN9ON DBK SEE LEGEND NOTE NUMBERS H8 S ting5 SW DEW PANEL LAYOUT SEQUENCE PMT IWO AND GENERAL NOrei DATE 6/3/10 SBD(S)- ADG11IQS6U1V CP11023. HVAC. INC. WIRING DIAGRAM LEGEND A Amber light— Heating on or heat wheel operating LP Low oil pressure switch AC Automatic summer winter change over LS Lead sulfide flame detector AD Access door switch LT Interval timer AP Air proving switch MA Modulating damper motor AR Auto reset thermal cutout MB Modulating room thermostat AS Alarm contact MD Mixed air or discharge air controller AT Outside air controller MH Modulating high limit control AX Auxiliary high limit switch ML Modulating low limit control B Blue light— Clogged filters or blocked intake MOV Main oil solenoid valve or cooling on MP Manual potentiometer BB Buck and boost transformer MR Modulator regulator valve BE Bonnet fan timer element MV Main gas safety shut —off valve BF Bonnet fan switch NF Non —fused disconnect switch BL Blower switch NT Night thermostat BOV By —pass oil valve OH Oil heater BP By —pass gas valve OHL Oil temperature high limit BS Burner switch OHT Oil heater thermostat BV Blocked vent switch OL Magnetic starter overloads CA Combustion air switch OR Inlet air sensor CB Motor control terminal board OT Over— riding timer CC Cadmium sulphide cell OTC Oil temperature burner control CL Cooling lockout control OU Occupied— unoccupied switch CO Convenience outlet P8 Manual pushbutton CP Capacitor PC Oil photocell CS Clogged filter or intake switch PL Push —to —test indicator light CT Cooling thermostat PM Power monitor CU Customer control PN Pneumatic control CV Combination pilot safety or valve /main gas valve PO Post —purge timer or controller CZ Circuit analyzer PR Protectorelay /Flame safeguard DC Discharge temperature limit control PS Pilot safety relay DE Economizer control and damper motor PT Pre —purge timer DF Differential pressure proving switch PV Pilot gas solenoid valve DM Two position damper motor R Red light— Burner safety shutdown or pilot on ON Day —night or day— off —night switch RA Return air damper switch DP Damper proving end switch RH Refrigerant hot gas by —pass solenoid valve DR Door switch RL Refrigerant liquid line solenoid valve DS Draft switch RT On —off room thermostat DT Delay timer SA Selectra amplifier DU Ductstat SC System switch DV Timed water dump valve SD Discharge temperature selector dial DZ Discharge air sensor SE Sequencer EC Enthalpy control SF Summer fan switch EF Contact to /for exhaust fan interlock SIG Signal converter /conditioner EG Equipment ground SL Manual high limit switch ES End switch SM Smoke detector EV Evaporative cooling pump motor SP Spark ignition system EX Exhaust switch or control SR Space temperature selector FC Fan con trol SS Manual two speed switch FD Fused disconnect switch or circuit breaker ST Space temperature sensor FE Scanner type flame detector SV Steam /Hot water valve FF Firestat SW Season switch FL Float switch T1 24 Volt transformer FR Flame rod T2 115 Volt transformer FRM Firing rate motor T3 230 Volt transformer FS Fuel selector switch TC Time clock FV Water fill valve TG Two stage gas valve FZ Freezestat TL Operating temperature limit control GN Ignition transformer TM Timing motor HA Hand off —auto switch TS Thermostat in sump— breaks on temperature fall HC Heating and cooling thermostat TT Two stage thermostat HE Electric heating elements TV Three way valve HG High gas pressure switch UV Scanner type flame detector HL High limit switch VM Venter motor HTL Heat limiters VP Venter proving switch HO High oil pressure switch VR Venter starting relay HP Heat wheel pressure switch VS Venter motor with proving switch HS Heating control switch VV Vent valve normally open HT Heating thermostat W White light— Blower operating or exhauster operating HU Humidistat XB Burner switch (unit control panel) HV Heat —vent switch XF Blower switch (unit control panel) HW Heat wheel control switch XO Alarm silencing switch LF Low fire hold switch XR Heater off remote switch (unit control panel) LG Low gas pressure switch XS System switch (unit control panel) LH Light /heavy oil selector switch XW Season switch (unit control panel) HASTINGS HVAC LL Low limit XX Audible buzzer or alarm DWG. S -58 R. RAIL 20 Nov. 1991 Rev. 28 Oct. 1992 Rev. 13 Mar. 2000 GENERAL NOTES 1. Circuit breaker (no fuses required) used 13 All field wiring must comply with applicable where designated. local electrical codes, ordinances, and regulations. 2. To facilitate shipping, some items shown as factory wired may be unhooked and tagged 14 Control circuit wiring to be NEC class 1. for reconnection in field. No additional wiring or conduit is required on these items. 3. Disconnect fuse sizing based on one time Replacement wire or cable must be equivalent general purpose time delay type. 19 to original wire or cable in gauge size and 4. Unit grounding needs to be a low impedance temperature rating. connection that will handle RF frequencies, Draft switch (DS) may be a sail switch (M2 -1) for the electronic equipment. 23 located on exhauster motor on smaller units. Factory installed wiring Field installed wiring WIRE COLOR DESIGNATIONS Factory connection or wire nut BLK Black GRN Green RED Red Terminals in master control panel BLU Blue ORG Orange WHT White BRN PRP YEL Yellow O Terminals in remote control panel W/T White with tracer Terminals in burner control panel Terminals in evaporative cooler COUNTERFLO, PARAFLO, UFO, ODF, AFX (Floor Mtd) control panel 1M or 1R Blower Motor Starter or Relay Coil O Connection point on wire plug 2M or 2R Exhauster Starter or Relay Coil 3M or 3R Burner Motor Starter or Relay Coil 0 Circuit analyzer lights 4M or 4R Oil Pump Motor Starter or Relay Coil M1 1 or 3 Phase Blower Motor M2 1 or 3 Phase Exhauster Motor A Available as optional equipment. M3 1 or 3 Phase Burner Motor M4 1 or 3 Phase Oil Pump Motor Furnished by others. Relays indicated by 5R, 6R, 7R, etc; Special notes found on face of the Burner Relays indicated by 1K, 2K, etc; wiring diagram. Wires to be shielded and grounded at one VHR 5 end or in separate conduit. For Selectra the 1M or 1R Supply Air Blower Motor Starter or Relay Coil shield must be grounded at the Amplifier end. 2M or 2R Exhaust Air Blower Motor Starter or Relay Coil 3M or 3R Heat Wheel Motor Starter or Relay Coil A Designates components external to master control M1 1 or 3 Phase Supply Air Blower Motor enclosure on units requiring components to be M2 1 or 3 Phase Exhaust Air Blower Motor designated. Refer to "Ratings of Loads External M3 1 or 3 Phase Heat Wheel Motor to Control Panel" sheet for ratings of external Relays indicated by 5R, 6R, 7R etc; Toads. Time clock contacts TC1 TC3 closed during day, SYSTEMS, DIRECT FIRED UNITS, EVAP COOLERS open during night. Contacts TC2 TC4 open during day, closed during night. Motors indicated by M1, M2, M3 etc; Starters indicated by 1M, 2M, 3M, etc; Relays indicated by 1R, 2R, 3R, etc; Vent valve second main valve not required for all applications, see final bill of material. 11 Fuses not required if total heat amps is 48 or be— low. Disconnect may be fused or non —fused type. A If manual potentiometer is used for mixed air applications, reverse the "B" and "W" leads. Components are not required for all applications. If not used terminals will be jumpered. See final bill of material. A 4 Components are not required for all applications. See final bill of material. HASTINGS HVAC DWG. S -58 R. RAIL 20 Nov. 1991 Rev. 28 Oct. 1992 Rev. 13 Mar. 2000