Loading...
HomeMy WebLinkAbout333 Eclipse Ind Pkwy - Technical TECHNICAL Permit# -1 02 Address 22 F.5 ti Y v-vvy Project description mow 0k01d k hon- Date the permit was finaled 4 ID' 19~ Number of technical pages PHILLIP B. MCCULLOCH, P.E. Structural Engineering Services Tele: (541)- 778 -8070 1655 Scofield Street Central Point, Oregon 97502 STRUCTURAL CALCULATIONS Proposed Steel Building Foundation Plan Fite: New Lean -To Building PORT ANGELES HARDWOOD Port Angeles, Washington •JB Steel, Contractor September 12, 2011 %cy p d 1 .3u4u a p c.N\— Cti 11 •4 o U r, O Q? JD r r R 0 a" c <C hI II NMI CD rU., zzd wiz cc U cc 0 0 —I O N LLB 0 LIU w 4— t >4 P (i) c Go d 7 w' 7, O? U N 0 O 0 O N C x 'O N" CI) N o ca a'll to U U O n� y� cu Q u) --1 Q t w L C37 U ;5, N co N N a9 C C> O N CZ Vl a) 0 O O t0 cn a7 d CZ -J n cn �o cnzoin o cu 0 E 0 W G-0 lion "r"I Co 0 CU c -a° cra o o r„ a o o II Miff o 'er.. u Qz �W2 NN r,Z7r7ZZ •of) its O Q U 1-1 cu H 0 u7 ...c 0,1 c ct O. c O C N O A N N OObb O j ai? a. b a roar "aNt� Qc0 aua)a)a>o� 0!!.' (1 0 a) 0 m t =c0U LLBCC EtIY(? o 0 w Nb ro axe o iamro�+ ti c4 Z V} U L L S_ L— N y 3 `O "C3 .L LL ll llH cn 5 .2 n O,. m N s3,; a te Ca Z H R 0 ft em t 5 3 Ai ...(26 C=-'.. a 4- r� e� t �J K x;2.5 7, .77 1 7 't r L''.. G 1 t... t I. F P Metallic Building Systems FRAME ID #02 USER NAME:mfpablo DATE: 9/ 2/11 PAGE: 2 -3 ss 50./21.667/13.833 20./10 JOB NAME:1124053SMPMT-LE:m2_d -1.fra MAX. SUPPORT REACTIONS FOR LOAD COMBINATIONS *LOCATION: Gridlines: 1 4_ i. NOTES:(1) All reactions are are kips and kip -ft. TIME:14:43:43 (2) These reactions are from loads determined from the applicable code for ASD design'. Seismic loads are limit state and include magnification factors when so required by the seismic provisions of the•applicable code for ASD design. It is the responsibility of the foundation designer to apply the load factors and load l ,-nm3 n,r; ,n, Fnr r11� ryrr f.,,, -,A-+ jn An REACTION NOTATIONS HL- O HR VL VR I A B 1 LOAD COMBINATION MAXIMUM REACTION TABLE COLUMN -A -B BASE PLATE 8.0X13.0X0.375 10.0X13.OX0.375 ANC. RODS (4) -3/4 (4) -3/4 LOAD COMB HL VL LNL HR VR LNR GRAVITY LOAD COMBINATION 1 3.1 11.8 0.0 -3.0� 11.9 0.0 2 2.9 11.6 0.0 -3.1 12.1 0.0 WIND LOAD COMBINATION 101 5.5` 7.61 0.0 2.5 1.51 0,0 59 -4.9 -5.4 .0.0 -1.2 -0.8 0.0 103 5.2 9.5 0.0 2.9 3.3 0.0 57 -4.4 =8.O 0.0 -1.7 -3.2 0.0 71 3.6 0.9 0.0 6.7 -7.1 .0.0 90 -1.1 2.6 0.0 -3.6 6.4 0.0 92 -1.5 4.5 0.0 -3.3 8,3 0.0 69 4.1 1.6) 0.0 6.2 -9LSL 0.0 TRANSVERSE EARTHQUAKE LOAD COMBINATION 11 1.6 4.11 0.0 -0.1 3.01 0.0 14 -0.6 0.1 0.0 -0.8 2.0 0.0 15 1.2 1.8 0.0 0.5 0.4 0.0 10 -0.3 2.4 0.0 -1.4 4.71 0.0 BASS -ONLY' EARTHQUAKE LOAD COMBINATION 31 3.7 6.4 0.0 0.9 2.3 0.0 26 l -2.4 -0,9 0.0 -2.1 4.2 0.0 27 3.0 3.7 0.0 1.5 -0.5 0.0 30 -1.9 1.6 0.0 -2.7I 7.1 0.0 f lJ "�-7'F--- I DO D ��e7 v (L IC.; Z 5 //ff `t Metallic Building Systems FRAME ID #02 USER NAME:mfpablc DATE: 9/ 2/11 PAGE: 2 -4 ss 50./21.607/13.813 20.110 J09 NAME:11240530MP9ILE:m2 d -1.fra MAX. SUPPORT REACTIONS FOR LOAD COMBINATIONS *LOCATION, Gridlines: 1 NOTES:(1) All reactions are in kips and kip -ft. TIME:14:43:43 (2) These reactions are from loads determined from the applicable code for ASD design. Seismic loads are limit state and include magnification factors when so required by the seismic provisions of the applicable code for ASD design. It is the responsibility of the foundation designer to apply the load factors and load r ri.. -•-,r fnr r1�� rr rcrn f »+•r4�r +rn Ar -ci—n REACTION NOTATIONS TOAD COMBINATION DESCRIPTION 1 DL +COLL +SNOW 2 DL +COLL +SNOW 10 1.10990L +1.1099CQLL +0.91EQ 11 1.1099DL +1.1099COLL 0.91EQ 14 0.4901DL +0.91EQ 15 0.4901DL 0.91EQ 26 0.743DL +2.5EQ 27' 0.743DL -2.5EQ 30 1.357DL +1.357C0LL +2.5EQ 31 1.3570L +1.357COLL -2.5EQ 57 0.6DL' +WL1 59 0.6DL +WL2 69 0.6DL +WL3 71 0.6DL +WL4 90 DL +COLL +0.75SNOW +0.75WL1 92 DL +COLL +0.75SNOW +0.75WL2 101 DL +COLL +0.75SNOW +0.75WL3 103 DL +COLL +0.75SNOW +0.75WL4 goo() i 4k 4x 3 ;I b 7?`" S Y 3 i 2.a 306 e, 2-6:%' Metallic Building Systems FRAME ID #01 USER NAME:mfpablo DATE: 9/ 2/11 PAGE: 1 -3 ss 50./21.667/25.157 20./10 JOB NAME:11240538MPEILE:m1_d -l.fra MAX. SUPPORT REACTIONS FOR LOAD COMBINATIONS *LOCATION: Gridlines: 2. 3 -r- NOTES: (1) All reactions are in kips and kip -ft. TIME :14:38:39 (2) These reactions are from loads determined from the applicable code fcr.ASO design. Seismic loads are limit state and include magnification factors when so required by the seismic provisions of the applicable code for ASD design. It is the responsibility of the foundation designer to apply the load factors and load combinations appropriate for the concrete foundation design. (3) The seismic overstrength factor (Omega) is not included in the ^LEQ" Load Group reactions. REACPIONQ®�3'A'rIa55E -ONLY" combination reactions include an overstrength factor of: 2.000 v �v "c0 HL f HR 1 VR *�A1 I B 1 LOAD COMBINATION MAXIMUM REDACTION TABLE COLUMN -A -B BASE PLATE 8.0X13.0X0.375 10.0X14.OX0.375 ANC. RODS (4) -3/4 (4) -3/4 LOAD COMB HL VL LNL HR VR LNR GRAVITY LOAD COMBINATION 1 5.4 20.8 0.0 -5.2 20.6 0.0 14 0.3 -1.4 -3.2 -0.3 -2.2 -3.2 13 0.3 -1.4 -3.2 -0.3 -2.2 -3.2 2 5.1 20.5 0.0 5.4 20.8 0.0 WOND LOAD cOMBINATTON 81 8.3 13.8 0.0 1.7 6.21 0.0 55 5.9 -5.4 0.0 -1.5 0.0 0.0 83 7.7 17.3 0.0 2.4 9.4 0.0 57 .1.9 15,0 5.2 -0.6 -16.4 5.9 67 4.4 2.1 0.0 8.1 -7.5' 0.0 78 0.1 7.8 0.0 -5.9 12.1( 0.0 114 5.3 14.0 0.0 -5.7 17.3 0.0 59 1.8 -13.4 -5.2 -0.5 18.1. -5.9 TRANSVERSE EARTH¢ITAKB LOAD COMBINATION 11 2.8 6.6I 0.0 -0.2 4.4 0.0 16 1.3 0.0 0.0 -1.3 3.0 0.0 17 1.8. 2.71 0.0 0.7 0.3 0.0 10 -0.4 3.91 0.0 -2.3 7.2 0.0 'BASE-ONLY' EARTHQUAKE LOAD COMBINATION 35 6.0 10.2 0.0 1.51 3.3 0.0 30 3.9 1.6 0.0 -3.31 6.2 0.0 31 4.8 5.7 0.0 2.4 1.2 0.0 34 -2.9 2.6.1 0.0 4,5 10.9 0.0 CD7 Metallic Building Systems FRAME ID #01 USER NAME:mfpablo DATE: 9/ 2/11 PAGE: 1 ss 50./21.667/25.267 20./10 JOB NAYE:11240538MPRILE:m1 d -1.fra MAX. SUPPORT REACTIONS FOR LOAD COMBINATIONS *LOCATION: Gridlines: 2 NOTES :(1) All reactions e in kips and kip -ft. TIME:14:38:39 (2) These reactions are from loads determined from the applicable code for ASD design. Seismic loads are limit state and include magnification factors when so required by the seismic provisions of the applicable code for ASD design. It is the responsibility of the foundation designer to apply the load factors and load combinations appropriate for the concrete foundation design. (3) The seismic overstrength factor (Omega) is not included in the "LEQ' Load Group reactions. gprIoNSpcIMSE- ONLY" combination reactions include an overstrength factor of': 2.000 j. LOAD COMBINATION DF„SCRIPTION 1 DL +COLL +SNOW 2 DL +COLL +SNOW 10 1.1099DI; +1.1094COLL +0.91EQ 11 1.1099DL +1.1099COLL 0.91EQ 13 0.4901DL +0.91RBUPEQ 14 0.4901DL +0.91RBUPEQ 16 Q.4901DL +0.91EQ 17 0.4901DL 0.91EQ 30 0.743DL +2.5EQ 31 0.743DL -2.5EQ 34 1.357DL +1.357COLL +2.5EQ 35 1.357DL +1.357CCLL -2.5EQ 55 0.6DL +WL2 57 0.6DL +LWL1 +RBUPLW 59 0.6DL +LWL2 +RBUPLW 67 0.6DL +WL4 78 DL +COLL +0.75SNOW +0.75WL1 81 DL +COLL +0.75SNOW +0.75WL3 83 DL +COLL +0.75SNOW +0.75WL4 114 DL +COLL +0.75SNOW +0.75LWL3 +0.75RBDWLW